05-3904 (AR) Title 24TITLE 24 REPORT
Title 24 Report for:
Valdivia Residence
'54-360 Avenida Juarez
La Quinta, CA 92253
Project Designer:
Stephen R. Nieto
78-120 Calle Estado Ste. 206
La Quinta, CA 92253
Report Prepared By:
Stephen R. Nieto
South West Concepts
78120 Calle Estado, Suite 206
La Quinta, CA 92253
(760) 564-4707
'CITY OF LS UDE A
BUILDING &
APPROVED
FOR CO
DA � o�BY 7
Job Number:
10104A
Date:
6/23/2005
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number: 10104A User Number: 5970
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary
HVAC System Heating and Cooling Loads Summary_
Room Load Summary
n
1
2
3
6
8
12
14
EnergyPro 3.1 By EnergySoft Job Number: ,10104A User Number: 5970
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Valdivia Residence 6/23/2005
Project Title Date
54-360 Avenida Juarez La Quinta
Project Address Building Permit #
South West Concepts (760) 564-4707 Plan Check I Date
Documentation Author Telephone
Computer Performance r 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 2,373 fl? Average Ceiling Height: 8.1 ft
Total Conditioned Slab Area: 2,373 fl?
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 2 ❑ Raised Floor
FFNFSTROTIAN
Shading Devices
Type
Orientation
Const.
Component
p
Frame
Assembly
Location/Comments
Type
Type
U -Value
(attic, garage, typical, etc.)
R-30 Roof(R.30.2xl2.16)
Wood
0.035
Exterior Roof
R-13 Wall w/1" EPS
Wood
0.059
Exterior Wall
R-19 Wall (W.19.2x6.16)
Wood
0.065
Exterior Wall
Solid Wood Door
Wood
0.387
Exterior Door
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
FFNFSTROTIAN
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Left
(North)
67.0
0.87
0.70
Bug Screen
X❑ ❑
❑ ❑X
Rear
(East)
73.3
0.85
0.70
Bug Screen
❑X ❑
❑ X❑
Right
(South)
56.5
0.87
0.70
Bug Screen
X❑ ❑
❑ X❑
Skylight
1.7
0.94
0.73
None
❑ X❑
❑ ❑X
Front
(West)
30.0
0.87
0.70°
Bug ScreenX❑
❑
❑ X❑
Rear
East
20.0
0.87
0.70
Bug Screen
X❑ ❑
❑ o
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑❑
❑❑
El El
El
El El
El
El
El El
Run Initiation Time: 06/23105 08:45:33
Run Code: 1119541533
Ener
Pro 3.1 By Ener
Soft
User Number: 5970
Job Number: 10104A
Pa e:3 of 15
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Valdivia Residence 6/23/2005
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design -Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type . Comments
Cpntral Furnace 92% AFUE Ducts in Attic 4.2 Setback Res HVAC 2
rpntral Furnace 92% AFUE
Duct-, in Attic
42
Setback
Res HVAC 1
Cooling Equipment Minimum
Type (air conditioner, Efficiency .
heat pump, evap. cooling) (SEER)
Duct
Location
(attic, etc.)
Duct
R -Value
Thermostat Location /
Type Comments
Split Air Conditioner 12.0 SEER
split Air Conditioner 12 0 SEFR
Ducts in Attic
D i -tc in Attic
4.2
4.2
Setback
Setback
Rpc HVAC 2
Rps HVAC 1
WATER HEATING SYSTEMS
Water Heater Water Heater
System Name Type
Distribution
Type
Rated 1
# in Input
Syst. Btu/hr
Tank
Cap.
(gal)
Energy Fact! 1 External
or Recovery Standby Tank Insul.
Efficiency Loss (%) R -Value
Standard Gas 50 gal or Less Small Gas Standard
1 - 40,000
50
0.53 n/a 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Stephen R. Nieto
Title/Firm: Stephen R. Nieto Title/Firm: South West Concepts
Address: 78-120 Calle Estado Ste. 206 Address:
La Quinta, CA 92253
Telephone:
Lic. !��
�/Z of
(sig e (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
78120 Calle Estado, Suite 206
La Quinta, CA 92253
Telephone: 760 564-4707
-5 /Cw
(signature) (date)
(signature/stamp) • (date)
Run Initiation Time: 06/23/05 08.45.33 Run Code: 1119541533
EnergyPro 3.1 By EnergySoft User Number: 5970 - Job Number: 10104A PageA of 15
Certificate of Compliance: Residential (Addendum) CF -1 R
Valdivia Residence 6/23/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
.s... e.s... n,.e.,,.....o.e.. inac tha adem�acv of the iustification. and may refect a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field
The HVAC System 'Res HVAC 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Res HVAC 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 06123/05 08:45:33 Run Code: 1119541533
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page:5 of 15
Mandatory Measures Checklist:_ Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
'§150(.): Minimum R-19 ceiling insulation.
❑ § 150(b): Loose fill insulation manufacturers labeled R -Value.
150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
❑'§
not apply to exterior mass walls).
' §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
04150(d):
❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
a§ 118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§ 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1.. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
a§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
a§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
FXJ §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page:6 of 15
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
X—] 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted,canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of, pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
F§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
a§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3,1 By EnergySoft User Number: 5970 Job Number: 10104A Page:7 of 15
Computer Method Summary
(Part 1 of 3) C -2R
-Latdi-via-Re-sidenrim
6m. 9nQ5
Project Title
J.ua�ez—LaS2uinta
Date
_EA--A�cenida
Project Address
Building Permit #
-S911t1L1L1Le_1
(760) 564-4707
Plan Check/Date
Documentation Author
Telephone
C�m�ute�erformanCe
15
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 2.55
2.41
0.14
Space Cooling 34.42
33.50
0.92
Domestic Hot Water 11.75
11.64
0.11
Totals 48.73
47.55
1.17
Pprr_pnt hpttpr than Standard:
2.4%
Total Conditioned Floor Area: 2,373 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Building Type: Single Fam Detached
Building Front Orientation: (West) 270 deg Total Fenestration Area: 10.5%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 19,166 ft 3
Number of Stories: 2 Total Conditioned Slab Area: 2,373 ft 2
BUILDING ZONE INFORMATION # of
Zone Name Floor Area Volume Units
Re.s1- r. 730 6,022 0 *11
.BPQ HVAC 1 1-643 X3.,144 _0...6.2
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
Root— Z30 603 0
ANall 1.168 0.059 _2.Z0 -90
Wall II 117 0.059 _a 90
Wall 59 0.065 90 90
Wall 343 0.065 180 90
noon 20 0.387 1812 _9.0
Roof— 6.641 6..005. 0. 92
WaII— 102 --U59- _27-0 '90
_Do-oL— 20 0.387 _27.0 90
-Wall— 37-6_ —0-059_ —0 9.0
Wall -----152 0059 90 90
Door 20 0.387 20 90
-Wall— 62 6.Il5,9- 180 _9.0_
Solar
Gains
Zone Type
—Gonditioned—
Conditiooed_
Reference
V
- -
►/ ■ ;..
►1 ■R-13waiiyviv Fps
VA ■ .
►1 ■ W.
11 ■ : W -
►1 ■ smd w ,,i n..
1/ ■ :..
MN ■ : Wall w1l" EPS
►/ ■ Solid ... D..
►.1 ■ .PS
/' ■
M El Solid Wood Door
►1 ■ R-1 3 Wall vv/1 EPS
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
■ ■
Thermostat
Type
—S.etback—
___S_eiback—
Vent
Hot. Area
8 —❑la
8 _Na
Location / Comments
2nd�loor_Zone
2ndJ=lODLZOne
2nd-aooLZone
2nd Floor Zone
2nd Floor Zone
2odE1onL7one
-ISt�ln.Of_ZOnP
-.sLEInnLZone
-- st-ElooLZone
_1St Elnnr 7one
_Jst_F:lonr 7nne
-ist Floor lone
sst- looLZone
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page:8 of 15
Computer Method Summary (Part 2 of 3) C -2R
Valdivia Residence 6/23/2005
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
J-
1Nindo-w Left (North
4.0_
0.870
0.70
0 g0. Qoub1Q etal Clear_Qef3u1L-
2nd Floor 7nnp
2
Window Left
(North)
15.0
0.870
0.70
0
90 Double Metal Clear Default
2nd Floor Zone
3
Window Rear
(East)
33.3
0.850
0.70
90
90 Double Metal Clear Default
2nd Floor Zone
4
Window Right
(South)
10.0
0.870
0.70
180
90 Double Metal Clear Default
2nd Floor Zone
5
dight Left
(North)
1.7
0.940
0.73
0
22 Double Metal Clear Default
1st Floor Zone
6
Window Front
(West)
15.0
0.870
0.70
270
90 Double Metal Clear Default
1 st Floor Zone
7
Window Front
(West)
15.0
0.870
0.70
270
90 Double Metal Clear Default
1 st Floor Zone
8
Window Left
(North)
24.0
0.870
0.70
0
90 Double Metal Clear Default
1st Floor Zone
9
Window Left
(North)
24.0
0.870
0.70
0
90 Double Metal Clear Default
1 st Floor Zone
1Q
Window Rear
(East)
20.0
0.870
0.70
90
90 Double Metal Clear Default
1 st Floor Zone
11
Window Rear
(East)
40.0
0.850
0.70
90
90 Double Metal Clear Default
1st Floor Zone
12
Window Right
(South)
24.0
0.870
0.70
180
90 Double Metal Clear Default
1 st Floor Zone
1Q
Vvindow Riaht
(, outh)
22.5
0,870
0.70
180
90 Double Metal Clear Default
1 st Floor Zone
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt. [-Ext. RExt. Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
1.0
4.0
5.5
0.1 2.0 2.0
2
Bug Screen
0.76
3.3
4.5
5.5
0.1 2.0 2.0
3
Bug Screen
0.76
6.6
5.0
2.0
0.1 2.0 2.0
4
Bug Screen
0.76
_ 4.0
6.0
2.0
0.1 2.0 2.0
5
None
1.00
6
Bug Screen
0.76
5.0
_ 3.0
2.0
0.1 2.0 20
7
Bug Screen
0.76
5.0
3.0
2.0
0.1 2.0 2.0
8
Bug Screen
0.76
4.0
4.0
2.0
0.1 2.0 2.0
9
Bug Screen
0.76
4.0
6.0
2.0
0.1 2.0 2.0
_
10
Bug Screen
0.76
5.0
4.0
2.0
0.1 2.0 2.0
_
11
Bug Screen
0.76
6.6
6.0
2.0
0.1 2.0 2.0
_
12
Bug Screen
0.76
4.0
6.0
2.0
0.1 2.0 2.0
13
Bug Screen
0.76
5.0
4.5
2.0
0.1 2.0 2.0
I EnerovPro 3.1 By EnerovSoft User Number: 5970 Job Number: 10104A Page:9 of 15
Computer Method Summary (Part 3 of 3) C -2R
Valdivia Residence 6/23/2005
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 90 076 0 0 0 1 st Floor Zone
HVAC SYSTEMS
Heating Equipment
Minimum Distribution Type
Type (furnace, heat
Efficiency and Location
Duct Thermostat
Location /
pump, etc.) (AFUE/HSPFXducts/attic, etc.)
R -Value Type
Comments
Central Furnace
92°o AFUE Ducts in Attic
4.2 Setback
Res HVAC 2
Central Furnace
92%AFUE Ducts in Attic
4.2 Setback
Res HVAC 1
Pipe Insul.
Hydronic Piping Pipe
System Name Length
Diameter Thick.
Cooling Equipment
Minimum Duct
Type (air conditioner,
Efficiency Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER) (attic, etc,)
R -Value Type
Comments
Split Air Conditioner
12.0 SEER Ducts in Attic
4.2 Setback
Res HVAC 2
Split Air Conditioner
12.0 SEER Ducts in Attic
4.2 Setback
Res HVAC 1
WATER HEATING SYSTEMS
Ratedl Tank
Energy Fact'
1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery
Standby R -Value
System Name
Type Type
Syst. (Btu/hr) (gal)
Efficiency
Loss (%) Ext.
Standard Gas 50 gal or Less
Small Gas Standard
1 40,000 50
0.53
n/a 12
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. .
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Run Initiation Time: 06/23/05 08:45:33 Run Code: 1119541533
Ener Pro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page: 10 of 15
Computer Method Summary (Addendum) C-2117%
Valdivia Residence 6/23/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
.............4..4....... o..the rinn.— of the inetifiratinn and may raiart a huildina or desion that otherwise comolles
based on the adequacy of the special justification and documentation submitted. Plan T Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan I Field
The HVAC System "Res HVAC 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System 'Res HVAC 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 06/23/05 08:45:33 Run Code: 1119541533
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page: 11 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
Valdivia Residence
DATE
6/23/2005
SYSTEM NAME
FLOOR AREA
Res HVAC 2
730
RING
Number of Systems
1
Heating System
Output per System
37,000
Total Output (Btuh)
37,000
Output (Btuh/sgft)
50.7
Cooling System
Output per System
23,200
Total Output (Btuh)
23,200
Total Output (Tons)
1.9
Total Output (Btuh/sgft)
31.8
Total Output (sgft/Ton)
377.6
Air System
CFM per System
895
Airflow (cfm)
895
Airflow (cfm/sgft)
1.23
Airflow (cfm/Ton)
462.9
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
Sensible
754
13,966
-424
325
12,977
0
698
649
0
0
0
0
0
0
0
0
0
698
649
15,363 -424 14,275
BDP CO. 563AN024-A. 17,983 1,411 37,000
Dte: values above given at ARI conditions I I
:ATING SYSTEM PSYCHROMETRICS (Airstre;
Total Adjusted System Output17 983 1,411 37,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK [7777;9 2 pm I Jan 12 am
26.0 of 69.3 of 69.3 of 108.2 of
Outside Air
0 cfm
Supply Fan Heating Coil
895 cfm
69.3 of
res at
Supply Air Ducts
107.5 of
ROOMS
70.0 of
Return Air Ducts `S� I
DOLING SYSTEM P.SYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
115.0 / 73.5 of 78.7 / 62.1 of 78.7 / 62.2 of 59.9 / 55.4 of
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 60.6 / 55.7 of
895 cfm 40.1% R.H. ROOMS
78.7/62.10F 78.0/61.9OF
i
Return Air Ducts
EnergyPro 3.1 By Energysoft User Number: 5970 Job Number: 10104A Page:12 of 15
PROJECT NAME DATE
Valdivia Residence 6/23/2005
SYSTEM NAME FLOOR AREA
Res HVAC 1 1,643
NEERING
Number of Systems
1
Heating System
Output per System
112,000
Total Output (Btuh)
112,000
Output (Btuh/sqft)
68.2
Cooling System
Output per System
58,000
Total Output (Btuh)
58,000
Total Output (Tons)
4.8
Total Output (Btuh/sqft)
35.3
Total Output (sgft/Ton)
339.9
Air System
CFM per System
2,055
Airflow (cfm)
2,055
Airflow (cfmisgft)
1.25
Airflow (cfm/Ton)
425.2
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROME'
26.0 of 69.5 of
Outside Air
0 cfm
. ) ( &
Supply Fan
2055 cfm
69.5 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
CFM I
Sensible
1,136
27,800
-237 L 569
21,204
0
1,390
1,060
0
0
0
0
01
0
0
0
0
1,390
1,060
30,580 -237 23,324
BDP CO. 563AN060-A 44,617 4,020 112,000
Total Adjusted System Output 44,617 4,020 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
RICS (Airstream Temperatures at Time of Heat
69.5 of 105.0 of
Heating Coil
Return Air Ducts
rRICS (Airstream Temperatures at Time of Coo
15.0/73.5OF 78.6/62.3OF 78.6/62.4OF . 55.0/53.6OF
#J1 ;P 7
Outside Air O° `
0 cfm Supply Fan
2055 cfm
78.6/62.3 of
Cooling Coil
h Return Air Ducts '*I
Supply Air Ducts
104.5 of
ROOMS
70.0 of
Supply Air Ducts
55.6 / 53.9 OF
40.8% R.H. ROOMS
78.0/62.1OF
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page:13 of 15
(ROOM LOAD SUMMARY I
PROJECT NAME
Valdivia Residence
DATE
6/23/2005
SYSTEM NAME
Res HVAC 2
FLOOR AREA
730
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING
PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM I
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
2nd Floor Zone
2nd Floor
1
754
13,966
-424
754
13,966
-424
325
12,977
PAGE TOTAL 1 754 13,966 -424 325 12,977
TOTAL 1 754 13,966 -424 325 12,977
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page:14 of 15
(ROOM LOAD SUMMARY I
PROJECT NAME
Valdivia Residence
DATE
6/23/2005
SYSTEM NAME
Res HVAC 1
FLOOR AREA
1,643
ROOM LOAD SUMMARY
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM I
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
1stFloor Zone
1st Floor
1
1,136
27,800
-237
1,136
27,800
-237
569
21,204
PAGE TOTAL 1 1,136 27,800 -237 569 21,204
TOTAL 1 1,136 27,800 237 569 21,204
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 10104A Page: 15 of 15
6/14/05
54360 Avenida Juarez — Valdivia Residence Addition (Application #04-4610)
(Steve Nieto: 760-564-4707; Robert Valdivia:)
05/26/04: Application submitted (expiration date: 11/22/04)
10/15/04: Plans approvable, but detached garage must be completed prior to
issuance of this permit (date approximate)
1.1 /10/04: Plan review extension request letter received
11/10/04: Extension of plan review granted
05/23/05: Extended plan review expired; complete resubmittal required