0010-091 (AR) Title 24TITLE 24 REPORT
Title 24 Report for:
John Bell
Avenida Juarez
La Quinta, CA
Project Designer:
Report Prepared By:
Joan D. Hacker
Insu-form Inc.
68255 Corta Road
Cathedral City, CA 92234
(760) 324-0216
Job Number:
CITY OF LA QUINTA_._
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
Date: DATE BY
Y 9/14/00
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 2.1 By EnergySoft Job Number: User Number: 2655
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
1
'2
3
6
7
14
16
EnergyPro 2.1 By EnergySoft Job Number: User Number 2655
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
John Bell 9/14/00
Project Title Date
Avenida Juarez La Quinta
Project Address Building Permit #
Insu-form Inc. (760) 324-0216
Plan Check /Date
Documentation Author Telephone
Computer Performance 15 Field Check I Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 2,023 ft2 _
Total Conditioned Slab Area: 2,023 ft2
Building Type:
Frame
Type
(check one or more)
Location/Comments
(attic, garage, typical, etc.)
X❑ Single Family Detached (SFD)
❑ Addition Alone
❑ Single Family Attached (SFA)
X❑ Existing Building
❑ Multi -Family •
❑ Existing Plus Addition
Front Orientation: (Northeast) 45 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units:
1.00
Number of Stories:
1 ❑ Raised Floor
Component
Type
Frame
Type
Const.
Assembly
U -Value
Location/Comments
(attic, garage, typical, etc.)
Slab On Grade
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
R-19 Wall (W.19.2x6.16)
Wood
0.065
Exterior Wall
R-38 Roof (R.38.2xl4.16)
Wood
0.028
Exterior Roof
R-0 Wall (W.0.2x4.16)
Wood
0.386
Exterior Wall
Solid Wood Door
None
0.387
Exterior Door
R-11 Roof (R.11.2x6.16)
Wood
0.076
Exterior Roof
FENESTRATION
Chtorlinn nAm%,;r•
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
SF
U -Value
SHGC
roller blind, etc.
shadescreen,
etc.
Yes / No
Yes / No
Front
(Northeast)
96.0
0.87
0.70
Drapery
Bug
Screen
x❑
❑
❑ 0
Front
(Northeast)
10.5
0.72
0.73
Drapery
Bug
Screen
a
❑
❑ a
Left
(Southeast)
16.0
0.87
0.70
Blind
Bug
Screen
x❑
❑
❑ x❑
Rear
(Southwest)
144.0
0.85
0.70
Drapery
Bug
ScreenX❑
❑
❑ Q
Right
(Northwest)
64.0
0.87
0.70
Drapery
Bug
Screen
X❑
❑
❑ X❑
Left
(Southeast)
16.0
0.87
0.70
Drapery
Bug
Screen
X❑
❑
❑ x❑
❑
❑
❑ ❑
❑
❑
❑ ❑
El
1:1
El 1-1
1:1
El
El F1
1-1
EJ
EJ El
Run Initiation Time: 09/14/00 14:43:18
Run Code: 968938998
EnergyPro
2.1 By Ener
Soft
User Number: 2655
Job Number:
Pa e:3 of 17
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
John Bell 9/14/00
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
Central Furnaces 80% AFUE Ducts in Attic 4-2 Setback Addition
Central Fumice 80% AFUE Ducts in Attic 2.1 Sesthack Living_7nne
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 10.1 SEER Ducts in Attic 49 S .tha .k Additinn
Split Air Conditioner 10.0 SEER Ducts in Attic 21 S -tha .k Living Innes
WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (05) R -Value
Standard Gas 50 gal or Less Small Gas Standard 1 40-000 50 0-53 nta 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
%rVIVWLIAIV%rC 0 1 H 1 CIVICIV I
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer orWn'e"r (per Business & Professions Code) Documentation Author
Name, sV tw • 1l c— Name: Joan D. Hacker
Title/Firm: Title/Firm: Insu-form Inc.
Address: ' SYS7 / ✓ore,Z Address: 68255 Corta Road
Cathedral City CA 92234
Telephone: _ (;o - 3355• Telephone: (760) 324-0216
LIC. #:
�► 9/r/al,
(sign a (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(sig(ure (date)
tsignature/stamp) (date)
Run Initiation Times 09/14/00 14.43.18 Rin Code: 96893899
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: PageA of 17
`Certificate of Compliance: Residential (Addendum) CF -1 R
John Bell 9/14/00
Project Title , Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
Jastu un Lilt autquacy ul Me special Ju5tlrlcatl011 ana 000umentation suornmea.
The DHW System "Standard Gas 50 gal or Less" Energy Factor= 0.530. An EF below 0.58 requires an R-12 External Blanket.
HERS Required Verification
These features must be confirmed and tested by a certified HERS rater under the supervision of a CEC approved HERS
Plan I Field
KI wv. v. 11w 9 IaLci 9911,10L UV%.UInenL LIM ntw venncaLuvn ana uiagnostic testing or mese measures on a corm CF -W. plan Field
Run Initiation Time: 09/14/0014:43:18 Run Code: 968938998
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 17
-Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties
as binding minimum component specifications.
ESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. I DESIGNER
ilding Envelope Measures
-§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
§ 150(b): Loose fill insulation manufacturers labeled R -value.
'§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls).
'§ 150(d): Minimum R-13 raised floor insulation in wood framed floors.
§ 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch.
§118: Insulation specified or installed meets quality standards. Indicate type and form.
§116-17: Feriestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
ace Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 extemal insulation or R-16
combined internal/external insulation, piping between heat source and tank insulated.
3. Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R-4 or greater), buried or exposed
piping in recirculating sections of hot water systems, cooling system piping below 55 deg F.
-§150(m): Ducts and Fans
1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections
601603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shall be
sealed with mastic tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181,
UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m).
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated
dampers.
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating.
2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light.
hting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed
ceiling are IC (insulation cover) approved.
EnergvPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 17
Computer Method Summary
(Part 1 of 3) C -2R
John RP -11
Project Title
9/14/00
Date
Av _nida Juarez
La - uinta
Project Address
Building Permit #
Insu-form Inc_
(760) 324-0216
Documentation Author
Telephone
plan Check/Date
Comnuter Performance
Compliance Method (Package or Computer)
15 Field Check/Date
Climate Zone
Source Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Existing+Addition Budget Adjustment
Space Heating
5.96
12.06
-6.10
Ratio F: 12601 2023 = 0.623
Space Cooling
45.51
80.99
-35.48
BudgetAdj: 0.623 X (135.74- 67.46) = 42.53
Domestic Hot Water
12.94
12.82
0.12
The budget shown to the left has been increased using
Totals
42.53 + 64.41 = 106.94
105.87
1.07
this Budget Adjustment based upon Existing building
information shown on the C -2R which follows this form.
GENERAL INFORMATION
Conditioned Floor Area: 2,023 Floor Construction Type: X❑ Slab Floor
Building Type: Single Fam Detached ❑ Raised Floor
Building Front Orientation: (Northeast) 45 deg
Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,970
Number of Stories: 1 Slab Floor Area: 2,023
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
Additinn 76 763 0 iR rnnditinnPd Sethark _2 n/a
Living 7nne- 1260 11 340 t) R9 Conditioned Setback _� n/a
OPAQUE SURFACES Act.
Type Area U -Val. Azm. Tilt
Wall 170 0.065 45 90
Nall 214 0 065 135 gn
Wall 156 0 065 225 gn
Wall 67 0.065 315 90
Wall 410 0.065 315 90
Roof 763 0 028 -0 a
Wall 308 0.386 45 90
nnnr 20 0.387 45_ _go
Wall 88 0.386 135 AQ
Mall 304 0.386 _225 _9d
Wall 94 0.386 315 90
Roof 1,260 0.076 45 0
Solar
Gains
Location / Comments
Addition
Addition
Additinn
Addition
Addition
Additinn
Living 7nne
Living 7nne
Living 7nne
Living 7nne
Living_7one
Living 7nne
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 17
Computer Method Summary (Part 2 of 3) C -2R
John Bell 9/14/00
Project Title Date
FENESTRATION SURFACES
U -Value Act. Glazing Type Location/
# Twe Area SHGC Azm. Tilt Comments
J_
Window
Front
(Northeast)
40.0
0.870
0.70
45
AQ Douhle Mtl Uncoated Defailt
Addition
2
Window
Front
(Northeast)
10.5
0.720
0.73
45
90 Double Mtl Uncoated Default
Addition
3
Window
Left
(Southeast)
16.0
0.870
0.70
135
90 Double Mtl Uncoated Default
Addition
4
Window
Rear
(Southwest)
64.0 `
0.850
0.70
225
90 Double Mtl Uncoated Default
Addition
5
Window
Right
(Northwest)
48.0
0.870
0.70
315
90 Double Mtl Uncoated Default
Addition
6
Window
Front
(Northeast)
40.0
0.870
0.70
45
90 Double Mtl Uncoated Default
Living Zone
Z
Window
Front
(Northeast)
16.0
0,870
0-70
45
90 Double Mtl Uncoated Default
Living Zone
8
Window
Left
(Southeast)
16.0
0.870
0.70
135
90 Double Mtl Uncoated Default
Living Zone
5
Window
Rear
(Southwest)
80.0
0.850
0.70
225
90 Double Mtl Uncoated Default
Living Zone
1Q
Window
Right
(Northwest)
16.0
0,870
0.70
315
-90 Double Mti Uncoated Default
Living Zone
INTERIOR AND EXTERIOR SHADING
Window Overhang
Left Fin Right Fin
#
Interior
Shade
Type
SHGC Exterior Shade Type
SHGC
Hgt. Wd. Len. Hgt. LExt. REA
Dist. Len. Hgt. Dist. Len. Hgt.
1
Drapery
0.68 Bug
Screen
0.76
5.0 4.0 0.6 0.1 0.6 0.6
2
Drapery
0.68 Bug
Screen
0.76
7.0 1.5 10.0 0.1 10.0 10.0
3
Blind
0.47 Bug
Screen
0.76
4.0 4.0 0.6 0.1 0.6 0.6
_
4
Drapery
0.68 Bug
Screen
0.76
8.0 8.0 16.0 0.1 16.0 16.0
5
Drapery
0.68 Bug
Screen
0.76
6.0 8.0 2.0 ' 0.1 2.0 2.0
_
T
Drapery
0.68 Bug
Screen
0.76
5 0 4.0 2.0 01 -0 _2..0
7
Drapery
0.68 Bug
Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
_
T
Drapery
0.68 Bug
Screen
0.76
4.0 2.0 2.0 0.1 2.0 2.0
9
Drapery
0.68 Bug
Screen
0.76
6.8 6.0 16.0 0.1 16.0 16.0
10
Drapery
0.68 Bug
Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
I EneravPro 2.1 By EnerovSoft User Number: 2655 Job Number: Paae:8 of 17 1
Computer Method Summary
(Part 3 of 3) C -2R
John Bell
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
9/14/00
Project Title
Addition
Central Furnace 80%AFUE Ducts in Attic 2.1 Setback
Date
THERMAL MASS FOR HIGH MASS DESIGN
Area
Thick.
Heat
Inside Location
Type (sf)
(in.)
Cap. Cond. Form 3 Reference
R -Val. Comments
PERIMETER LOSSES
Addition
Split Air Conditioner 10.0 SEER Ducts in Attic 2.1 Setback
Living Zone
WATER HEATING SYSTEMS Ratedl Tank
F2
Insulation
or Recovery Standby R -Value
Type Length
Factor
R -Val. Depth Location / Comments
0.53 n/a 12
Slab Perimeter 67
0_76
0.0 0 Addition
Slab Perimeter 960_76
0.0 0 Addition
Slab Perimeter 130
0_76
0.0 0 Living Zone
Slab Perimeter 580_76
0.0 0 Living Zone
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
Comments
Central Furnace 80%AFUE Ducts in Attic 4.2 Setback
Addition
Central Furnace 80%AFUE Ducts in Attic 2.1 Setback
Living Zone
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat
Location /
heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type
Comments
Split Air Conditioner 10.1 SEER Ducts in Attic 4.2 Setback
Addition
Split Air Conditioner 10.0 SEER Ducts in Attic 2.1 Setback
Living Zone
WATER HEATING SYSTEMS Ratedl Tank
Energy Facts 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name Type Type Syst (Btu/hr) (al)
Efficiency Loss (%) Ext
Standard Gas 50 gal or Less Small Gas Standard _ 1 40,000 50
0.53 n/a 12
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
I EnergyPro 2.1 By EnergySoft User Number: 2655 . Job Number: P.—O of 47
Computer Method Summary' (Addendum) C2 -R
John Bell 9/14/00
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
�aacJU — arc Quo4—Y V. %. JFJ6 UI JU.1111WMUV11 QIIU UUGUIIICIIUAIVII SUUIIIIIICU. Plan Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
FJ.v 1. 1.1 .1—N Mg 111 U.JL UW{ UIIIWIIL IIIC IICIU YCIIIIGdlIU11 d11U Uldgnos[Ic resting or rnese measures on a rorm Lf -6R.
Plan
Field
Run Initiation Time: 09/14/0014:43:18 Run Code: 968938998
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 10 of 17
Computer Method Summary
(Part 1 of 3) C -2R
John Rell
Project Title
9/14/00
Date
Avenida hjqrP7 I a Quinta
Project Address
Building Permit #
Insu-form Inc_
(760) 324-0216
Documentation Author
Telephone
Plan Check/Date
Computer Performance
Compliance Method (Package or Computer)
15
Climate Zone
Field Check/Date
Source Energy Use Standard
Proposed
Compliance
(kBtulsf-yr) Design
Design
Margin
Space Heating 4.53
14.57
-10.04
Space Cooling 45.09
103.52
-58.42
Domestic Hot Water 17.84
17.66
0.19
Totals 67.46
135.74
-68.28
GENERAL INFORMATION
Conditioned Floor Area: 1,260 Floor Construction Type: XX Slab Floor
Building Type: Single Fam Detached ❑ Raised Floor
Building Front Orientation: (Northeast) 45 deg
Number of Dwelling Units: 1.00 Total Conditioned Volume: 11,340
Number of Stories: 1 Slab Floor Area: 1,260
BUILDING ZONE INFORMATION # of
Zone Name Floor Area Volume Units
OPAQUE SURFACES Act.
Type Area ' U -Val. Azm. Tilt
Wall 308 0.386 45 go
Door 20 0.387 45 go
Wall 88 0.386 135 ga
Wall 304 0.386 225 gQ
Wall 294 0.386 315 gQ
Rnof 1260 0.076 45 -0
Solar
Gains
Y / N Form 3 Reference
Thermostat Vent
Zone Type Type Hgt. Area
Cnnrtit0nnPr1 Sethack _� n/a
Location I Comments
Living Zone
1 iving_ZnnP
Living 7onP
Living 7nne
I iving�ane
Living 7one
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Paw: 11 of 17 1
Computer Method Summary
(Part 2 of 3) C -2R
John Bell
9/14/00
Project Title
Date
" FENESTRATION SURFACES
U -Value
Act.
Glazing Type
Location/
# Type
Area
SHGC
Azm.
Tilt
Comments
_1_ Window Front (Northeast)
40 0_
-0 870_
070
45
qD. Do jhl . Mtl L In .oat -d
Default
Living Zone
2 Window Front (Northeast)
16.0
0.870
0.70
45
90 Double Mtl Uncoated Default
Living Zone
3 Window Left (Southeast)
16.0
1.280
0.80
135
90 Single Mtl Uncoated Default
Living Zone
4 Window Rear (Southwest)
80.0, ,
0.850
0.70
225
90 Double Mtl Uncoated Default
Living Zone
5 Window Right (Northwest)
16.0
0.870
0.70
315
90 Double Mtl Uncoated Default
Living Zone
INTERIOR AND EXTERIOR SHADING
Window Overhang
Left Fin Right Fin
# Interior Shade Type SHGC Exterior Shade
Type
SHGC
Hgt. Wd. Len. Hgt. LExt.
REA. Dist. Len. Hgt. Dist. Len. Hgt.
1 Drapery
0.68 Bug
Screen
0.76
5.0 4.0 2.0 0.1 2.0
2.0
2 Drapery
0.68 Bug
Screen
0.76
4.0 4.0 2.0 0.1 2.0
2.0
_
3 Drapery
0.68 Bug
Screen
0.76
4.0 4.0 2.0 0.1 2.0
2.0
4 Drapery
0.68 Bug
Screen
0.76
6.8 6.0 16.0 0.1 16.0
16.0
_
5 Drapery
0.68 Bug
Screen
0.76
4.0 4.0 2.0 0.1 2.0
2.0
Run Initiation Time: 09/14/00 14:43:18 Run Code: 968938998
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 12 of 17
Computer Method Summary
(Part 3 of 3) C -2R
John Bell
9/14/00
Project Title
and Location,
Duct Thermostat
Date
THERMAL MASS FOR HIGH MASS DESIGN
(AFUE/HSPF)(ducts/attic,
Area
Thick.
Heat
Inside Location
Type (sf)
(in.)
Cap. Cond. Form 3 Reference
R -Val. Comments
PERIMETER LOSSES
F2
Insulation
Type Length
Factor
R -Val. Depth Location / Comments
Slab Perimeter 130.
0_76
0.0' 0 Living Zone
Slab Perimeter 58
ALM
0.0 0 Living Zone
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location,
Duct Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.)
R -Value Type
Comments
Central Furnace
80%AFUE
Ducts in Attic
2.1 Setback
Living Zone
Pipe Pipe
Hydronic Piping
Insul.
System Name
Length Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling) (SEER)
(attic, etc,)
R -Value Type
Comments
Split Air Conditioner
10- O SEE
Ducts in Attic
2.1 Setback
Living Zone
WATER HEATING SYSTEMS
Ratedl Tank
Energy Facts Tank Insul.
Water Heater
. Water Heater Distribution
# in Input Cap.
1
or Recovery Standby R -Value
System Name
Type
Type
Syst. (Btu/hr) (al)
Efficiency Loss (%) Ext
Standard Gas 50 gal or Less
Small Gas
Standard
_1 40,000 50
0.53 n/a 12
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
John Bell
9/14/00
SYSTEM NAME
FLOOR AREA
Addition
- .763
Number of Systems
1
Heating System
Output per System
53,000
Total Output (Btuh)
53,000
Output (Btuh/sqft)
69.5
Cooling System
Output per System
28,000
Total Output (Btuh)
28,000
Total Output (Tons)
2.3
Total Output (Btuh/sgft)
36.7
Total Output (sgft/Ton)
327.0
Air System
CFM per System
950
Airflow (cfm)
950
Airflow (cfm/sgft)
1.25
Airflow (cfm/Ton)
407.1
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
:ATING S
26.0 of
*---;I
Outside Air
0 cfm
69.1 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel Latent
CFM
I Sensible
I 16,167 355 19 624
DAY AND NIGHT 561CJ030-* 19,402 5,641 53,000
Total Adjusted System Output 19,402 5,641 53,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK F Aua 2 om I F Jan 12 am
3YCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
69.1°F 69.10F 121.2°F
Supply Air Ducts
Supply Fan Heating Coil 120.3 of
950 cfmE ROOMS
70.0 of
Return Air Ducts q�
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.4 of 78.7 / 65.1 of 78.7 / 65.1 of 59.7 / 58.4 of
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 60.4 / 58.7 of
950 cfm 49.6% R.H. ROOMS
78.7/65.1 of 78.0 / 64.9 of
EnergyPro 2.1 By EnergySoft User Number: 2655
Return Air Ducts
Job Number:
14 of 17
I
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
John Bell
9/14/00-
SYSTEM NAME
FLOOR AREA
Livinq Zone
1,260
Number of Systems
1
Heating System
Output per System
71,000
Total Output (Btuh)
. 71,000
Output (Btuh/sqft)
56.3
Cooling System
Output per System
40,000
Total Output (Btuh)
40,000
Total Output (Tons)
3.3
Total Output (Btuh/sqft)
31.7
Total Output (sgft/Ton)
378.0
Air System
CFM per System
1,500
Airflow (cfm)
1,500
Airflow (cfm/sgft)
1.19
Airflow (cfm/Ton)
450.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible Latent
I CFM
I Sensible
2,117
33,928
2,762
936
41,721
0
1,696
2,086
0
0
0
0
0
0
0
0
0
1,696
2,086
37,321:::72 762 45 894
:xisting HVAC 27,434 9,512 71,000
Total Adjusted System Output 27,434 9,512 71,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 68.7 of 68.7 of 112.90F
Outside Air G)
0 cfm
Supply Fan Heating Coil
1500 cfm
68.7 of
111.0 / 77.4 of
Outside
�Jr
0 cfm
79.1/67.1 of '
K Return Air Ducts `{
79.1 / 67.1 of 79.1 / 67.1 of 62.0 / 60.9 of
Supply Fan Cooling Coil
1500 cfm
h Return Air Ducts `A
Supply Air Ducts
111.6 of
ROOMS
70.0 of
Supply Air Ducts
63.1 / 61.3 of
55.9% R.H. ROOMS
78.0 / 66.7 of
I
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 15 of 17
]ROOM LOAD SUMMARY
PROJECT NAME
John Bell
DATE
9/14/00
SYSTEM NAME
Addition
FLOOR AREA
763
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM I
SENSIBLE
Addition
Addition
1
779
14,697
355
779
14,697
355
331
17,840
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 16 of 17
ROOM LOAD SUMMARY
PROJECT NAME
John Bell
DATE
9/14/00
SYSTEM NAME
Living Zone
FLOOR AREA
1,260
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Living Zone
Existing Living
1
2,117
33,928
2,762
2,117
33,928
2,762
936
41,721
PAGE TOTAL
TOTAL
1 2,1171
33,928
2,762
936
41,721
1 2,117
33,928
2,762
936
41,721
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 17 of 17