Loading...
0403-031 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: CALDER CONTEMPORARY 54960 Avenida Juarez La Quinta, Ca 92253 Project Designer: Lendel Ventures, Inc. DBA Lench Design Group P.O. BOX 450 LA QUINTA, CA 92253-0450 760/564-1866 Report Prepared By: VERNA LENCH Lendel Ventures, Inc P.O. Box 450 La Quinta, CA 92253-0450 (760) 564-1866 Job Number: 3.1-1239 Date:' 2/9/2004 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATET�/� BY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 3.1-1239 User Number: 5454 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 7 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 14 EnergyPro 3.1 By EnergySoft Job Number: 3.1-1239 User Number: 5454 s ea Certificate of Compliance: Residential (Part 1 of 2) CF -1 R CALDER CONTEMPORARY- 2/9/2004 Project TitleDate 54960 Avenida Juarez La Quinta Project Address Building Permit # Lendel Ventures, Inc (760) 564-1866 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,139 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 2,139 f? Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑Raised Floor Component R-38 Roof(R.38.2x14.16) Slab On Grade Slab On Grade R-13 Wall w/1" EPS R-13 Wall (W.13.2x4.16) Solid Wood Door FENESTRATION Const. Frame Assembly Wood 0.028 n/a - 0.756 n/a 0.756 Wood 0.059 Wood 0.088 None 0.387 Location/Comments (attic, garage, typical, etc. Exterior Roof Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Wall Exterior Door Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 20.0 0.70 0.83 None ❑x❑ ❑ ❑x Front (West) 120.0 0.74 0.37 Bug Screen a ❑ ❑ a Right (South) 19.5 0.46 0.37 Bug Screen ❑ x❑ ❑ ❑x Right FSouth) 9.0 0.62 0.38 Bug Screen ❑X❑ ❑ ❑x Right (South) 25.0 0.61 0.39 Bug Screen ❑ x❑ ❑ X❑ Rear (East) 7.5 0.46 0.37 Bug Screen ❑ a ❑ o Rear (East) 4.0 0.61 0.39 Bug Screen ❑ o ❑ a Left (North) 4.5 0.46 0.37 Bug Screen ❑ x❑ ❑ a Left (North) 25.0 0.61 0.39 Bug Screen ❑ x❑ ❑ x❑ Left (Northeast) 18.0 0.61 0.39 Bug Screen ❑ X❑ ❑ a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 02/09/04 07:52:14 Run Code: 1076341934 EnergyPro 3.1 By Ener Sok User Number: 5454 0 Job Number: 3.1-1239 Pa e:3 of 15 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R CALDER CONTEMPORARY 2/9/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments t;entral Furnare 80% AFUE Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc.) Duct Thermostat Location / R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setback HVA(' SV,stem WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FGR -50-240 Small Gas Recirc/Demand 38,000 50 0.60 n/a n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES. NO DUPLICATION PERMITTED! uumt,uANGt J I A 1 tMtN I This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Lendel Ventures, Inc. DBA Lench Design Grou Address: P.O. BOX 450 A QUINTA CA 4 Telephon .I60/564-1 Lic. #: 2 • '°l •v r ent Agenc Address: Telephone: Name: VERNA LENCH Title/Firm: Lendel Ventures, Inc Address: P.O. Box 450 La Quinta, CA 92253-0450 Telephone: (760) 564-1866 I/ rV fig./ (si. .. IEnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 PageA of 15 Certificate of Compliance: Residential (Addendum) CF -1 R CALDER CONTEMPORARY 2/9/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )aseo on the adequacy oT the special /ustiTication ana aocumentation suomittea. Plan I Field The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1347 sqft Exposed Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C-213) - Verify Thermal Mass: 792 sqft Covered Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS NIvrwo1. 5 nC "�IAQ iaua mual, uwumnnt uie nein venncauon anu uiaynvsuc Twang or Tnese measures on a Torm t,r-orc. IPlan I Field avn EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page:5 of 15 1 Mandatory Measures Checklist: Residential MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. IDESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures 1150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. § 150(b): Loose fill insulation manufacturer's labeled R -Value. .§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in framed floors. § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ] §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ] §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. §150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §-115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures ] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. JEnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page:6 of 15 Computer Method Summary (Part 1 of 3) C -2R C=AI nFR CONTEMPORARY Project Title 2/9/2004 Date 54960 Avenida JuarP7 I a Qtflnta Project Address Building Permit # I PndPl VPntlfreS, Inc (760) 564-1866 Documentation Author Telephone Plan Check/Date Qomnuter Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.27 3.30 -0.03 Space Cooling 37.21 37.62 -0.41 Domestic Hot Water 12.50 10.80 1.70 Totals 52.98 51.73 1.26 GENERAL INFORMATION Conditioned Floor Area: 2,139 Floor Construction Type: ❑X Slab Floor Building Type: Single Fam Detached Raised Floor Building Front Orientation: (West) 270 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 21,390 Number of Stories: 1 Slab Floor Area: 2,139 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC SVctpm 913-9 _713gp 1 nn C=16tinnari SPthnrk n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt rYIN Y I N Rnnf _2,119 0.028 270 0 u wall 45 0.059 270 gn ® ❑ Wall 70 0.059 315 _gn ❑ Wall 118 0.059 270 90 ❑ Wall 20 0.059 180 _gn ❑ Wall 65 0.059 270 gn ❑ Will 610 0.059 180 An ❑ Wall 220 0.059 _90 90 ❑ Wall 43 n.0s9 o _go ® ❑ wan 70 0.059 An gn ❑ Wall 98 0.059 Q _gQ ❑ Wall 67 0.059 go _90 ❑ Wall 87 0.059 -n go ❑ W:;Il 97 0.059 45 _go ® ❑ Wall 15 0.059 0 _go ® ❑ wau 99.14 f) MR -0 _go ® ❑ Dnor 94 0.387 -a go QQ ❑ Form 3 Reference EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page:7 of 15 1 Computer Method Summary (Part 2 of 3) C -2R CALDER CONTEMPORARY 2/9/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Glazing Type Azm. Tilt Location/ Comments 1 Skylight Front est) 4.0 0 7Q0_ 0_A3 970 0 Skylight - Dual Glaze Whnle House 2 Skylight Front (West) 4.0 0.700 0.83 270 0 Skylight - Dual Glaze Whole House 3 Skvlight Front (West) 4.0 0.700 0.83 270 0 Skylight- Dual Glaze Whole House 4 Skylight Front (West) 4.0 0.700 0.83 270 0 Skylight- Dual Glaze Whole House 5 Skylight Front (West) 4.0 0.700 0.83 270 0 Skylight- Dual Glaze Whole House 6 Window Front (West) 40.0 0.740 0.37 270 90 Summit 5500 AI DP Low E Whole House L Window Front (West) 40.0 0,740 0.37 270 90 Summit 5500 Al DP Low E Whole House 8 Window Front (West) 40.0 0.740 0.37 270 90 Summit 5500 Al DP Low E Whole House 6 Window Right (,South) 4.5 0.460 0.37 180 90 Summit 5500 Al DP Low E Whole House -M Window Right (South) 7.5 0.460 0.37 180 -90 Summit 5500 Al DP Low E Whole House 11 Window Right (South) 7.5 0.460 0.37 180 90 Summit 5500 Al DP Low E Whole House 12 Window Right (South) 9.0 0.620 0.38 180 90 Glass Block Whole House _U Window MUM (South) 25.0 0.610 0.39 180 -90 Summit 5500 Al DP Low E Whole House 14 Window Rear (East) 7.5 0.460 0.37 90 90 Summit 5500 Al DP Low E Whole House 15 Window Rear (East) 4.0 0.610 0.39 90 90 Summit 5500 AI DP Low E Whole House 16 Window Left (North) 4.5 0.460 0.37 0 90 Summit 5500 Al DP Low E Whole House 17 Window Left (North) 25.0 0.610 0.39 0 90 Summit 5500 Al DP Low E Whole House 18 Window Left (Northeast) 18.0 0.610 0.39 45 90 Summit 5500 Al DP Low E Whole House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 Bug Screen 0.76 8.0 2.5 6.0 0. 6.Q 6.0 7 Bug Screen 0.76 8.0 2.5 6.0 0.1 6.0 6.0 8 Bug Screen 0.76 8.0 2.5 6.0 0.1 6.0 6.0 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 Run Initiation Time: 02/09/04 07:52:14 Run Code: 1076341934 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page:8 of 15 Computer Method Summary (Part 3 of 3) C -2R CALDER CONTEMPORARY 2/9/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 1 „347 3,5.0 _ 28 0_98 n/a _0 Whole House / Slah on Grade Concrete, Heavyweight 792 3_50 28 0_98 n/a 2 Whole House / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 179 0.76 0.0 0 Whole House Slab Perimeter 95 0.76 0.0 0 Whole House HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FGR -50-240 Small Gas Recirc/Demand 1 38,000 50 0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R CALDER CONTEMPORARY 2/9/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on the adequacy or the special Justmcation ana aocumentation sunmittea. Plan I Field The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1347 sgft Exposed Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 792 sgft Covered Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. r ne nr-ma rater must aocument me neia vermcation ana oiagnosuc testing of tnese measures on a torm GF -6R. Plan Field Run Initiation Time: 02/09/04 07:52:14 Run Code: 1076341934 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page:10 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CALDER CONTEMPORARY 2/9/2004 SYSTEM NAME FLOOR AREA HVAC System 2,139 Total Room Loads teturn Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts I-OTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,247 30,513 3,234 876 32,634 0 79.7 164.0 of 79.7 ( 64.0 of 55.0 153.8 of 1,526 1,632 0 0 0 0 0 0 0 0 Supply Fan Cooling Coil 0 1,526 1,632 33,5 3 234 35 898 YORK H4DH060S06 44,731 6,689 75,000 Total Adjusted System Output44,731 s,s89 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm C Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating -Peak 26.0 OF 68.2 OF 68.2 OF 105.0°F O Outside Air Supply Air Ducts 0 cfm 103.2 of Supply Fan Heating Coil 855 cfm ROOMS 68.2 of 70.0 of h Return Air Ducts `S COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 79.7 164.0 of 79.7 ( 64.0 of 55.0 153.8 of Supply Air Ducts O Outside Air 0 cfm Supply Fan Cooling Coil 56.7 / 54.4 of 855 cfm ROOMS 45.1% R.H. 79.7164.0 of 78.0163.5 of Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page: 11 of 15 ROOM LOAD SUMMARY PROJECT NAME CALDER CONTEMPORARY DATE 2/9/2004 SYSTEM NAME HVAC System FLOOR AREA 2,139 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Whole House Whole House 1 1,247 30,513 3,234 1,247 30,513 3,234 876 32,634 PAGE TOTAL 1 1,247 30,513 3,234 876 TOTAL 1 1,247 30,513 3,23411 876 32,634 32,634 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page: 12 of 15 ROOM HEATING PEAK LOADS Project Title Date CALDER CONTEMPORARY 2/9/2004 Room Information Desi n Conditions Room Name whole House Time of Peak Jan 12 am Floor Area 2,139 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 24 287 Infiltration: r1.00 X 1.064 X 2 139 X 10A0 X 6] X 44 = 8 347 `schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 32,634 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page: 13 of 15 2,119.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0280 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44.0 = = = = = = = = = c = 2,611 20.0 0.7000 44.0 616 perimeter = 203.5 44.5 9,056 1,555.5 0.0585 44.0 4,005 120.0 0.7400 44.0 3,907 31.5 0.4600 44.0 638 9.0 0.6200 44.0 246 72.0 0.6100 44.0 1,932 22 0,0885 44,0 868 24.0 0.3872 409 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 24 287 Infiltration: r1.00 X 1.064 X 2 139 X 10A0 X 6] X 44 = 8 347 `schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 32,634 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1239 Page: 13 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY CALDER CONTEMPORARY 2/9/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction 13011 Area U -Value X Whole House 780E 112°F 340E DETD1 X 51.0 X 34.0 X 30.6 X 34.0 X 34.0 X 34.0 X 34.0 X 30-6 X 108 Btu/hr 3,026 476 2,785 3,019 493 190 3 604 984 1. Design Equivalent Temperature Difference (DETD) Page Total 12 371 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight (Skylight) 1+ 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + (Skylight) Skylight (Sk)light) Skylight _(Skylight) Skylight (Skylight) Window 2680 2 FR DR (West) Window 2680 2 FR DR (West) Window 2680 2 FR DR (West) Window 1016 3 FO (South) Window 1016 5 FO South ( 0.0 x X x x X x x X X 1+ 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 4.0 x X x x x x X X x 152) X x x x X x X 0.954 = = = = = = = = __ = 580 ( 0.0 4.0 152) 0.954 580 ( 0.0 4.0 152)x 0.954 580 ( 0.0 4.0 152) 0.954 580 ( 0.0 4.0 152) 0.954 580 ( 23.5 16.5 73) 0.412 641 ( 23.5 16.5 73) 0.412 641 ( 23.5 16.5 73) 0.412 641 ( 0.0x 4.5X 3)x 0.41 59 ( 0.0 77775 32)x 0.412 99 Sched. Page Total a s82 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 2,139 X 0.500 Watts/sqft x 3.413 Btuh/Watt = 3,650 Occupants 1.00 X 2,139 X 245 Btuh/occ. / 333 sqft/occ. = 1,574 Receptacle 1.00 x 2,139 x 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Process 1.00 x 2,139 X 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Infiltration: I x � x Area x x � / 60] nJ DT _ Schedule Air Sensible Area Ceiling Height ACH .Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30 513 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2139 x 155 Btuh/occ. / 333 sgft/occ. = 996 Receptacle 1.00 x 2139 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process r 1.00 x 2139 x 0.000 Watts/sgft X I 3.41d Btuh/Watt = 0 Infiltration: I 1.00 x 4,77 x 2 13 x 10.00 x 0.50 / 60] 1 0.00263 = 2 238 `schedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,234 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1239 Page: 14 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY CALDER CONTEMPORARY 2/9/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: . Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area X U -Value Whole House 780F 1120F 340E Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 1016 5 FO (South) Wondnw 3030 M RI K Window 5050 XO (South) (South) Window 1016 5 FO x x x x X x x x x Window 2020 XO _(East) (East) Window 1016 3 FO (North) Window 5050 XO (North) Window 4046 XO (Northeast) 32) 0.423 ( 0.0 x1 x x x x X x x x + + + + + + + + t 7.5 x x x x X x x x x 32)X x X x x X )x 0.412 = = = = = = = = = 99 ( 0.0 1 9.0 32) 0.423 122 ( 0.0 '1 25.0 32) 0.434 347 ( 0.0 1 7.5 73) 0.41 226 ( 0.0 1 4.0 73) 0.434 127 ( 0.0 1 4.5 15)x 0.412 28 ( 0.0 1 25.0 15)X 0.434 163 ( 0.0 1 18.0 48) 0.434 375 ( i i Sched. Page Total 1 ass Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 2,139 X 0.500 Watts/sgft x 3.412 Btuh/Watt = 3,650 Occupants 1.00 x 2,139 X 245 Btuh/occ. / 333 sgft/occ. = 1,574 Receptacle 1.00 x 2,139 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 2,139 x 0.000 Watts/sqft x 3.412 Btuh[Watt = 0 Infiltration: [� x � x A13 x x � / 60] Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30513 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2139 x 155 Btuh/occ. / 333 sgft occ. = 996 Receptacle 1.00 x 2 139 x 0.000 Watts/sqft x 3 41 Btuh/Watt = 0 Process r 1.00 x 2139 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: I 1.00 x E 4,77 x 2 13 x 10.00 x 0.50 / 60] 0.00263 = 2 238 a Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,234 Ener Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1239 Page: 15 of 15