0106-089 (SFD) Title 24ill
TITLE 24 REPORT
Title 24 Report for:
Tradition Village Plan 1B
Tradition Golf Club
La Quinta, CA 92253
Project Designer:
McLarand Vasquez Emsiek & Partners, Inc.
1900 Main Street 8th Floor
Irvine, CA 92614
(949) 809-3300
Report Prepared By:
Tim Scott
.,_�. BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
(760) 346-0855
Job Number:
Date:
5/31/01
18-Itg Com%, L4
CITY.OF LA QUINTA
BUILDING & SAFETY DEPT
APPROVED
FOR CONSTRUCTION
DATE t"3-01 BY
offlc*' $q -
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is -
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 3.0 By EnergySoft
Job Number:
User Number: 3665
•
•
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Tradition Village Plan 1B 5/31/01
rojec i e Date
Tradition Golf Club La Quinta
vroject Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
oocumentation Author i a ep one
Computer Performance 15
Building ermi
Plan Check / Date
Hela GhecKDate
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,301 ft2 Average Ceiling Height:
Total Conditioned Slab Area: 3,301 f?
Building Type:
(check one or more)
® Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: All Four Orientations Floor Construction Type: FX_1 Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
Component
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Slab On Grade
Slab On Grade
FENESTRATION
Const.
Frame Assembly
Type U -Value
Wood 0.028
Wood 0.059
Na 0.756
Na 0.756
Location/Comments
(attic, garage, typical, etc.)
Exterior Roof
Exterior Wall
Exposed Slab w/R-0.0 Perimeter Insulation
Covered Slab w/R-0.0 Perimeter Insulation
Shading Devices
9.9 ft
Type Orientation
Area
Fenestration
Exterior
Overhang Side Fins
(SF)
U -Factor
SHGC
Shading
Yes / No
Yes / No
Rear
32.0
0.46
0.51
Bug ScreenX❑
❑
❑ x❑
Rear
32.0
0.48
0.51
Bug Screen
Q
❑
❑ X❑
Right
79.2
0.46
0.51
Bug Screen
❑
x❑
❑ x❑
Right
56.0
0.48
0.51
Bug Screen
❑
Q
❑ ❑X
Front
38.6
0.48
0.51
Bug Screen
❑X
❑
❑ ❑x
Front
32.0
0.46
0.51
Bug Screen
❑
Q
❑ XX
Front
32.0
0.48
0.51
Bug Screen
❑
X
❑ XD
Left
64.0
0.48
0.51
Bug Screen
❑
Q
❑ X❑
Left
110.0
0.46
0.51
Bug Screen
❑
®
❑ Pq
Left
44.0
0.46
0.51
Bug Screen
x❑
❑
❑ x❑
Rear
86.0
0.48
0.51
Bug Screen
❑
X❑
❑ X❑
Rear
78.7
0.46
0.51
Bug Screen
❑
®
❑ x❑
Run Initiation Time: 05/31/01 07:34:41
Run Code: 991319681
EnergyPro 3.0 By EnergySoft
User Number: 3665
Job Number:
Page:3 of 45
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: McLarand Vasquez Emsiek & Partners, Inc.
Address: 1900 Main Street 8th Floor
Irvine, CA 92614
Telephone: (949) 809-3300
Lic. #:
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Name:
Title/Firm:
Address:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
Telephone: (760) 346-0855
(signature) J (d te)
signature stamp date
Run Initiation Time: 05/31/01 07:34:41 Run Code: 991319681
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: PageA of 45
Certificate of Compliance: Residential
(Part 2 of 2)
CF -1 R
Tradition Village Plan 1B
5/31/01
•P
ro/ec f TifFe—Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and
Duct or
Type (furnace, heat Efficiency Location
Piping
Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.)
R -Value
Type Comments
Central Furnace 80% AFUE Ducts in Attic
4.2
Setback HVAC -1
Central Furnace 80% AFUE Ducts in Attic
4.2
Setback HVAC -2
Central Furnace 80% AFUE Ducts in Attic
4.2
Setback HVAC -3
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location
Duct
Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.)
R -Value
Type Comments
Split Air Conditioner 14.0 SEER Ducts in Attic
4.2
Setback HVAC -1
Split Air Conditioner 13.5 SEER Ducts in Attic
4.2
Setback HVAC -2
Split Air Conditioner 12.1 SEER Ducts in Attic
4.2
Setback HVAC -3
WATER HEATING SYSTEMS
Rated 1
Tank Energy Fact! 1
External
Water Heater Water Heater Distribution # in
Input
Cap. or Recovery Standby
Tank Insul.
System Name Type Type Syst. Btu/hr
(gal) Efficiency Loss (%)
R -Value
American PBG102-34S100- Large Gas Recirc/Time+Temp 1
100,000 33 0.94 0.0098
0.0
erican PBG102-34S100- Large Gas Recirc/Time+Temp 1
100,000 33 0.94 0.0098
0.0
•
tPV
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric
resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: McLarand Vasquez Emsiek & Partners, Inc.
Address: 1900 Main Street 8th Floor
Irvine, CA 92614
Telephone: (949) 809-3300
Lic. #:
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Name:
Title/Firm:
Address:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
Telephone: (760) 346-0855
(signature) J (d te)
signature stamp date
Run Initiation Time: 05/31/01 07:34:41 Run Code: 991319681
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: PageA of 45
Certificate of Compliance: Residential (Addendum) CF -1 R
Tradition Village Plan 1B 5/31/01
- Project Title Date
•
9
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
JGACV VII L 1 auaqual.y VI L11C APCNa1 jwnl {.all Vll a11U UVL U111U111a11V11 SUV1111LUM.
The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 403 sqft Exposed Slab Floor, 3.50" thick at Master Suite/Bedroom 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 827 sqft Covered Slab Floor, 3.50" thick at Master Suite/Bedroom 2
The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1463 sqft Exposed Slab Floor, 3.50" thick at Gllry/Liv/Din/Kit/Lndr/Pw r
The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 109 sqft Exposed Slab Floor, 3.50" thick at Guest House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 499 sqft Covered Slab Floor, 3.50" thick at Guest House
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an Field
-the HVAQ System - includes a Thermostatic Expansion Valve n access door or removable panel Must be
and a certified HERS rater must visually verify the installation of the TXV.
rove e
,
The HVAC System "HVAC -2" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be
and a certified HERS rater must visually verify the installation of the TXV.
provide
,
The HVAC System "HVAC -3" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be
and a certified HERS rater must visually verify the installation of the TXV.
rovide
,
Run InitiationTime: un Code: 991319681
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: - Page:5 of 45
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
• the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they
are shown elsewhere in the documents or on this checklist only.
40
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMEN
Building Envelope Measures
® "§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
❑ § 150(b): Loose fill insulation manufacturers labeled R -Value.
*§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to
exterior mass walls).
❑ '§ 150(d): Minimum R-13 raised floor insulation in framed floors.
❑ § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch.
® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
® §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
X§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
® §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA.
® §150(i): Setback thermostat on all applicable heating and/or cooling systems.
® §1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
®"§150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and
Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed
with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or
UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or
tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot
light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
Lighting Measures
® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
® 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and
recessed ceiling fixtures are IC (insulation cover) approved.
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:6 of 45
Computer Method Summary (Part 1 of 3) C -2R
Tradition Village Plan 113 5/31/01
•Project Title yate,
Tradition Golf Club La Qulnta
vrolect Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
Documentation Author I a ep one
Computer Performance 15
Building Permit v
Plan CheclUDate
Source Energy Standard
Use (kBtu/sf-yr) Design
Space Heating 3.70
Space Cooling 36.63
Domestic Hot Water 8.63
Totals 48.96
Facing
North Margin
0.028
Facing
East Margin
0
Facing
South Margin
1
Facing
West Margin
Masters uite/Bedroom 2
2.27 1.43
39.87 -3.24
5.89 2.74
3.31 0.39
39.17 -2.54
5.89 2.74
3.52 0.18
37.10 -0.47
5.89 2.74
3.00 0.70
37.34 -0.71
5.89 2.74
48.03 0.93
48.37 0.59
1 46.52 2.44
46.23 2.73
ItSUILL)
N13 CC) VIVILIr-b
142
i rns y -2K summarizes the results of a tour carainai orientation analysis. i ne pages that touow aescrnbe the tront tacing North occurence.
This plan has been analyzed with identical features in all orientations.
GENERAL INFORMATION
Conditioned Floor Area: 3,301
Building Type: Single Fam Detached
Building Front Orientation: All Four Orientations
Number of Dwelling Units: 1.00
Number of Stories: 1
BUILDING ZONE INFORMATION
Zone Name Floor Area Volume
Floor Construction Type: ❑X Slab Floor
❑ Raised Floor
Total Conditioned Volume: 32,800
Slab Floor Area: 3,301
# of Thermostat Vent
Units Zone Type Type Hgt. Area
HVAC -1 1,230 12,054 0.37 Sleeping SleepingStat 2 n/a
HVAC -2 1,463 15,274 0.44 Living LivingStat 2 n/a
• HVAC -3 608 5,472 0.18 Sleeping SleepingStat 2 Na
•
OPAQUE SURFACES Act.
Type Area U -Val. Azm
---S-oT-
Gains
Tilt Y / N
Form 3 Reference
Location / Comments
Roof
1,230
0.028
0
0
Ej
R-38 Roof (R.38.2xl4.16)
Masters uite/Bedroom 2
Wall
203
0.059
0
90
❑
R-21 Wall (W.21.2x6.16)
MasterSuite/Bedroom 2
Wall
142
0.059
180
90
❑
R-21 Wall (W.21.2x6.16)
MasterSuite/Bedroom 2
Wall
500
0.059
270
90
❑
R-21 Wall (W.21.2x6.16)
MasterS uite/Bed room 2
Roof
1,463
0.028
0
0
❑
R-38 Roof (R.38.2xl4.16)
Gllry/Liv/Din/Kit/Lndr/
Wall
98
0.059
0
90
❑
R-21 Wall (W.21.2x6.16)
Gllry/Liv/Din/Kit/Lndr/
Wall
553
0.059
90
90
❑
R-21 Wall (W.21.2x6.16)
Gllry/Liv/Din/Kit/Lndr/
Wall
192
0.059
180
90
❑
R-21 Wall (W.21.2x6.16)
Gllry/Liv/Din/Kit/Lndr/
Wall
96
0.059
270
90
❑
R-21 Wall (W.21.2x6.16)
Gllry/Liv/Din/Kit/Lndr/
Roof
608
0.028
0
0
❑
R-38 Roof (R.38.2x14.16)
Guest House
Wall
311
0.059
0
90
❑
R-21 Wall (W.21.2x6.16)
Guest House
Wall
114
0.059
90
90
❑
R-21 Wall (W.21.2x6.16)
Guest House
Wall
247
0.059
180
90
❑
R-21 Wall (W.21.2x6.16)
Guest House
Wall
99
0.059
270
90
❑
R-21 Wall (W.21.2x6.16)
Guest House
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Run Initiation Time: 05/31/01 07:34:41
Run Code: 991319681
EnergyPro 3.0
By EnergySoft
User Number: 3665 Job Number: Pagel of 45
Computer Method Summary (Part 2 of 3) C -2R
•
TraditProject ion le Date Village Plan 113 5/31/01
FENESTRATION 5UKFA(;F_5
# Type Area
1
Window
Rear
(South)
16.0
2
Window
Rear
(South)
32.0
3
Window
Rear
(South)
16.0
4
Window
Right
(West)
2.0
5
Window
Right
(West)
2.0
6
Window
Right
(West)
2.0
7
Window
Right
(West)
35.2
8
Window
Right
(West)
3.0
9
Window
Right
(West)
16.0
10
Window
Right
(West)
32.0
11
Window
Right
(West)
16.0
12
Window
Front
(North)
38.6
13
Window
Front
(North)
16.0
14
Window
Front
(North)
32.0
15
Window
Front
(North)
16.0
16
Window
Left
(East)
32.0
17
Window
Left
(East)
6.0
18
Window
Left
(East)
32.0
19
Window
Left
(East)
6.0
20
Window
Left
(East)
32.0
21
Window
Left
(East)
6.0
22
Window
Left
(East)
22.0
23
Window
Left
(East)
22.0
24
Window
Left
(East)
24.0
25
Window
Left
(East)
24.0
26
Window
Rear
(South)
22.0
27iOV
ndow Rear
(Soutfi)
iTT
28
Window
earSoutFi)
90 Sunair NonMtl Tinted
3T
29
Window
Rear(South)
0.460
32.0
INTERIOR AND EXTERIOR SHADING
2
2
4
5
s
-7-
f
.8
9
10
T1-
12
13
14
15
1fi
17
1S
fg
36
31
22
23
i4-
-2-5
26
27
28
29
Exterior Shade Type
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
BugScreen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
SHGC
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
0.460
0.51
180
90 Sunair NonMtl Tinted
0.480
0.51
180
90 Sunair NonMtl Tinted
0.460
0.51
180
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.480
0.51
270
90 Sunair NonMtl Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
0.480
0.51
0
90 Sunair NonMtl Tinted
0.460
0.51
0
90 Sunair NonMtl Tinted
0.480
0.51
0
90 Sunair NonMtl Tinted
0.460
0.51
0
90 Sunair NonMtl Tinted
0.480
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.480
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.480
0.51
180
90 Sunair NonMtl Tinted
-060-
03T
TSO-
-90unaiS rNonMtl Tinted
O460
030
T86-
-SO Sunair NonMtl Tinted
0.480
0.51
180
90 Sunair NonMtl Tinted
Location/
Comments
MasterSuite/Bedroom 2
MasterSuite/Bedroom 2
MasterSuitelBedroom 2
MasterS u ite/Bed room 2
MasterS u ite/Bed room 2
MasterS u ite/Bed room 2
MasterSuite/Bedroom 2
Master uite/Be room 2
MasterSuite/Bedroom 2
MasterSuitelBedroom 2
Maste rS uite/Bed room 2
Gllry/Liv/Din/Kit/Lndr/
_GT Fry1LW7iD n7KiULn-c F/ -
I ry/Liv/Din/ it/Ln r
Window Overhang Left Fin
gFl�rT Len. Hgt. LExt. RExt. -Dist. Len. Hgt."
0.76
8.0
4.0
2.0
0.1
2.0
2.0
0.76
8.0
2.0
2.0
0.1
2.0
2.0
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0:76
0:76-
8.0
4.810.0
0.1
10.0
10.0
__0_M
0T6
-0.76
076-
.76076
076
-0-.76-
.76676
-"6
OM
0�6
0.76
5.5
4.0
2.0
0.1
2.0
2.0
0.76
5.5
4.0
2.0
0.1
2.0
2.0
0.76
0.76
0.76
0.76
0.76
0.76
Run Initiation Time: 05/31/01 07:34:41 Run Code: 991319681
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number:
Right Fin
is6 t: Len. Rgt.
Page:8 of 45
Computer Method Summary (Part 2 of 3) C -2R
Tradition Village Plan 113 5/31/01
•Project Title -Da e
U- Act. . Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
30
31
S-2-
33
34
35
36
37
:T8-
T9
40
41
42
43
Window
Left
(East)
Window
Rear
(South)
Window
Rear
(South)
Window
Rear
(South)
Window
Right
(West)
Window
Right
(West)
7.3
16.0
3.7
2.0
2.0
2.0
2.0
2.0
2.0
16.0
32.0
16.0
24.0
3.0
INTERIOR AND EXTERIOR SHADING
0.460
0.51
180
90 Sunair NonMtl Tinted
0.460
0.51
180
90 Sunair NonMtl Tinted
0.460
0.51
180
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
90
90 Sunair NonMt Torted
0.460
0.51
90
90 Sunair NonMtl Tinted
0.460
0.51
180
90 Sunair NonMtl Tinted
0.480
0.51
180
90 Sunair NonMtl Tinted
0.460
0.51
180
90 Sunair NonMtl Tinted
0.480
0.51
270
90 Sunair NonMti Tinted
0.460
0.51
270
90 Sunair NonMtl Tinted
Gllry/Liv/Din/KiVLndrl
Gllry/Liv/Din/Kit/Lndr/
Gllry/Liv/Din/Kit/Lndr/
Guest House
Guest House
Guest House
Guest House
Guest House
Guest House
Guest House
Guest House
Guest House
Guest House
Guest House
Window Overhang Left Fin Right Fin
# Exterior Shade Type
SHGCgt�d- en. Hgt. LEA REA Dist. Len. gt. Dist. Len. Hgt.
-30 BugScreen
31 Bug Screen
0.76
32 Bug Screen
0.76
33 Bug Screen
0.76
34 Bug Screen
_
0.76
39 Bug Screen
_
0.76
iii Bug Screen
0.76
-37 Bug Screen
38 Bug Screen
0.76 -_
39 Bug Screen
0.76
T-6uB g c
4T Bug cs reen
4-2 Bug cS reen
X3 Bug c
Run Initiation Time: 05/31/01 07:34:41 Run Code: 991319681
EnergyPro 3.0 By EneravSoft User Number: 3665 Job Number: Page:9 of 45
Computer Method Summary (Part 3 of 3) C -2R
Tradition Village Plan 1B 5/31/01
•roP j-ecf-Tit e Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
•
Concrete, Heavyweight
827
3.50
28
0.98 n/a 2
Concrete, Heavyweight
1,463
3.50
28
0.98 n/a 0
Concrete, Heavyweight
109
3.50
28
0.98 n/a 0
Concrete, Heavyweight
499
3.50
28
0.98 n/a 2
PERIMETER LOSSES
mascerbuneresearoom z i ciao on urac
Gllry/Liv/Din/Kit/Lndr/ / Slab on Grade
Guest House / Slab on Grade
Guest House / Slab on Grade
HVAC SYSTEMS
Heating Equipment
Minimum
F2
Insulation
Efficiency
Type
Length
Factor
R -Val.
Depth
Location / Comments
Slab Perimeter
38
0.76
0.0
0
MasterSuite/Bedroom 2
Slab Perimeter
72
0.76
0.0
0
MasterSuite/Bedroom 2
Slab Perimeter
125
0.76
0.0
0
Gllry/Liv/Din/Kit/Lndr/
Slab Perimeter
23
0.76
0.0
0
Guest House
Slab Perimeter
72
0.76
0.0
0
Guest House
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.)
Central Furnace
80%AFUE
Ducts in Attic
Central Furnace
80%AFUE
Ducts in Attic
Central Furnace
80%AFUE
Ducts in Attic
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
Duct Thermostat Location /
R -Value Type Comments
4.2 Setback HVAC -1
4.2 Setback HVAC -2
4.2 Setback HVAC -3
Minimum Duct
Efficiency Location Duct Thermostat Location /
(SEER) (attic, etc,) R -Value Type Comments
Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1
Split Air Conditioner 13.5 SEER Ducts in Attic 4.2 Setback HVAC -2
Split Air Conditioner 12.1 SEER Ducts in Attic 4.2 Setback HVAC -3
WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
American P13G102-345100-2LPV Large Gas Recirc/Time+Temp 1 100,000 33 0.94
American P13G102-34S100-2LPV Large Gas Recirc/Time+Temp 1 100,000 33 0.94
0.0098 0.0
0.0098 0.0
1 For small gas storage (rated input - 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 05/31/01 07:34:41 Run Code: 991319681
EnergyPro 3.0 By Energysoft User Number: 3665 Job Number: Page:10 of 45
Computer Method Summary (Addendum) C2 -R
Tradition Village Plan 1B 5/31/01
• Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
C�
•
�nacu vu u1c aucy... y vc aFv. .way Jua...... w.. ouu... w .
The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 403 sqft Exposed Slab Floor, 3.50" thick at Master Suite/Bedroom 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 827 sqft Covered Slab Floor, 3.50" thick at Master Suite/Bedroom 2
The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1463 sqft Exposed Slab Floor, 3.50" thick at Gil ry/Liv/Din/Kit/Lndr/Pw r
The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 109 sqft Exposed Slab Floor, 3.50" thick at Guest House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 499 sqft Covered Slab Floor, 3.50" thick at Guest House
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an I Field
The system includes a Thermostatic.Expansion valve n access door or removable panel must be
and a certified HERS rater must visually verify the installation of the TXV.
proviaec,
The HVAC System "HVAC -2" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be
and a certified HERS rater must visually verify the installation of the TXV.
providec,
The HVAC System "HVAC -3" includes a Thermostatic Expansion Valve TXV). An access door or removable pane must be 11
and a certified HERS rater must visually verify the installation of the TXV.
rove e
,
Run InitiationTime: un Code: 991319681
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:11 of 45
INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R
• SimAddressPermit Number
An installation certificate is required to be posted at the building site or made available for all appropriate inspections.
(The information provided on this form is required; however, use of this form to provide the information is optional.)
After completion of final inspection, a copy must be provided to the building department (upon request) and the
building owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heating Equipment
Equip. # of Efficiency' Duct Duct or Heating Heat' Q9
Type (pkg., CEC Certified Mfr Name Identical (AFUE etc.)) Location Piping Load Capacity
heat pump) & Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr)
Cooling Equipment
Equip. CEC Certified Compressor # of Efficiency' Duct Cooling Cooling
Type (pkg. Unit Mfr Name & Identical (SEER, etc.) Location Duct or Load Capacity
heat pumps Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr)
T >= reads Greater Than or Equal to.
I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent
to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the
Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate
requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
WATER HEATING SYSTEMS:
CEC Certified Distribution If Recir- # of Rated2 Tank Effie 2 External
Heater Mfr Name Type(Std, culation, Identical Input (kW Volume ciency Standby Insulation
Type & Model Number Point -of -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (%) R -Value
2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input.
For instantaneous gas water heaters, list Recovery Efficiency and Rated Input.
3 R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58.
Faucets & Shower Heads:
All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111.
I, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to
or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy
Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for
manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 12 of 45
INSTALLATION CERTIFICATE (Part 2 of 7) CF -6R
• SiteAddress Permit Number
FENESTRATION / GLAZING:
Product U- Product Interior or
Value 1 SHGC1 Exteror Shading
(=<CF -1 R (=< CF -1 R # of Quantity Square Device or Comments/
Manufacturer/Brand Name value)2 valuey Panes (Optional) Feet Overhang Special Features
1e19;"2t:Ia001 all, 14
nN
8.
9.
10.
11.
12.
13.
14.
15.
1. Manufactured Fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 116 of the Energy Efficiency Standards.
• 2. Installed U -value must be less than or equal to values from CF -IR. Installed SHGC must be less than or equal to values from CF -IR, or a shading device (interior, exterior or overhang) is
installed as specified on the CF -11R. Alternatively, installed weighted average U -values for the total fenestration area are less than or equal to values from CF -1R.
I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2)
is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance (Form CF -1 R)
submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds
the appropriate requirements formanufactured devices (from Part 6), where applicable.
Item #s Signature, Date
(if applicable)
Item #s Signature, Date
(if applicable)
Item #s Signature, Date
(if applicable)
nlsal IngSubcontractor(Co.Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Installing Subcontractor (Co: Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
• COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 3.0 By Energysoft User Number: 3665 Job Number: Page: 13 of 45
INSTALLATION CERTIFICATE (Part 3 of 8) CF -6R
sited- rd ess
-Pe�mi� umber
DUCT LEAKAGE AND DESIGN DIAGNOSTICS
❑ DUCT LEAKAGE REDUCTION
Pressurization Test Results (CFM @ 25 PA)
Test Leakage (CFM)
Fan Flow
If Fan Flow is Calculated as 400 cfm/ton x number of tons, or as 21.7 x Heating Capacity in
Thousands of Btu/hr, enter calculated value here
If fan flow is measured, enter measured value here
Leakage Fraction = Test Leakage/(Measured or Calculated Fan Flow) _
Pass if leakage fraction — 0.06 ❑ ❑
Pass Fail
❑ For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed:
Duct Fan Pressurization at rough -in measured leakage (CFM)
❑ Yes ❑ No ❑ Pressure pan test or House pressurization test
❑ Yes ❑ No ❑ Visual Inspection of Duct Connections ❑ ❑
• Pass Fail
[:]THERMOSTATIC EXPANSION VALVE (TXV)
❑Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided
for inspection
Yes is a pass ❑ ❑
❑ THERMOSTATIC EXPANSION VALVE (TXV) Pass Fail
1 ❑ Yes ❑ No ACCA Manual D Design calculations have been completed, Duct
Design is on the plans and duct installation matches plans
2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified
fan flowmatches design from CF -1 R.
Measured Fan Flow =
Yes for both 1 and 2 is a Pass ❑ ❑
Pass Fail
❑ I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance
with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.]
Tests Signature, Datens-I talting Subcontractoro. Name
Performed OR General Contractor ( o. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 14 of 45
INSTALLATION CERTIFICATE (Part 3 of 8) CF -6R
•
Site AddressPermit Number
DUCT LOCATION AND AREA REDUCTION DIAGNOSTICS
❑ DUCT IN CONDITIONED SPACE '
❑ Yes ❑ No Duct in conditioned space criteria matches CF71 R
❑ ❑
Yes is a pass Pass Fail
❑ REDUCED DUCT SURFACE AREA
Measured duct exterior surface area in the following unconditioned duct locations (square feet):
Attics
Crawlspaces
Basements
Other (e.g., garages,
etc.)
• ❑ Yes ❑ No Duct surface area matches CFA R? Yes is a pass ❑ ❑
Pass Fail
•
❑ I, the undersigned, verify that the duct surface area and duct locations claimed for duct surface area reductions and duct location
improvements beyond those covered by default assumptions match those on the plans. [The builder shall provide the HERS
provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation
meet the requirements for compliance credit.)
ests Signature, Dater mg u con rac or o. ame
Performed OR General Contractor ( o. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: , Page:15 of 45
INSTALLATION CERTIFICATE (Part 4 of 7) CF -6R
• Site Address Permit Number
BUILDING ENVELOPE LEAKAGE DIAGNOSTICS
ENVELOPE SEALING INFILTRATION REDUCTION
Diagnostic Testing Results
Building Envelope Leakage (CFM @ 50 Pa) as measured by Rater
1. Q F1 Is measured envelope leakage less than or equal to the required level from CF1 R?
Yes No
2. ❑ ❑ Is Mechanical Ventilation shown as required on the CF -1 R?
Yes No
2a. F-1 0 If Mechanical Ventilation is required on the CF -1 R (Yes on Line 2), has it been
Yes No installed?
2b. ❑
F_�
Check this box yes if mechanical ventilation is required (Yes in line 2) and
Yes
No
ventilation fan watts are no greater than shown on CF -1 R. Measured Watts =
3. ❑
R
Check this box yes if measured building infiltration (CFM @ 50 Pa). is greater than
Yes
No
the CFM @ 50 values shown for an SLA of 1.5 on CF -1 R
(If this box is checked no, mechanical ventilation is required.)
4. ❑
❑
Check this box yes if measured building infiltration (CFM @ 50 Pa) is less than the
Yes
No
CFM @ 50 values shown for an SLA of 1.5 on CF -1 R, mechanical ventilation is
installed and house pressure is greater than minus 5 Pascal with all exhaust fans
operating.
• Pass if: 11 11
a. Yes in line 1 and line 3, or Pass Fail
b. Yes in line 1 and 2, 2a, and 2b, or
c. Yes in line 1 and Yes in line 4.
•
Otherwise Fail.
I, the undersigned, verify that the building envelope leakage meets the requirements claimed for building leakage reduction below
default assumptions as used for compliance on the CF -1 R. This is to certify that the above diagnostic test results and the work I
performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide
the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and
installation meet requirements for compliance credit.]
Tests Signature, Date Installing Subcontractor (Co.Name)
Performed OR General Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 16 of 45
0
INSTALLATION CERTIFICATE (Part 6 of 7) CF -611
Sife Address Permit Number
The following is an explanation of many of the input values required on this form:
WATER HEATING SYSTEMS
Distribution Systems: Refer to Residential Manual for more details.
Standard:
Standard - Supply prssure based system, no pumps
Pipe Insulation:
Pipe Insulation on all 3/4 -inch pipes
POU/HWR:
Point of Use/Hot Water Recovery System
Recirc/NoControl:
Recirculation loop with no controls
Recirc/Timer:
Recirculation loop with a timer
Recirc/Temp:
Recirculation loop with temperature control
Recirc/Time + Temp:
Recirculation loop with a timer and temperature control
Recirc/Demand:
Recirculation loop with demand control
Water Heater Type
Storage Gas, Oil or Electric
Heat Pump
Instantaneous Gas
• Instantaneous Electric
Large Storage Gas
Indirect Gas (Boiler)
•
Information Needed
Energy Factor
Recovery Efficiency
Standby Loss
Rated Input
Yes
No
No
No
Yes
No
No
No
No
Yes
No
No
Yes
No
No
No
No
Yes
Yes
Yes
No
Yes (AFUE)
No
Yes
FENESTRATION / GLAZING
Fenestration:
Windows, sliding glass doors, french doors, skylights, garden windows, and
any door with more than one square foot of glass
Operator Type;
Slider, hinged, fixed
U -Value:
Installed U -Value must be less than or equal to value from CF -1 R
OR
Installed weighted average U -Value for the total fenestration area
is less than or equal to value from CF -1 R
SHGC:
Installed SHGC must be less than or equal to value from CF -1 R
OR
Installed SHGC for the total fenestration area is less than or equal to value
from CF -1 R
OR
An interior shading device, overhang, or exterior shading device is installed
consistent with the CF -1 R
ShadingDevice:
Include when the building complied using an interior shading device: blinds,
opaque roller shades, blinds (do not list draperies), an exterior shading
device: woven sunscreen, louvered sunscreen, low sun angle sunscreen,
roll -down awning, roll -down blinds or slats (do not list bug screen), or an
overhang (include depth in feet)
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: ' Page: 17 of 45
9
•
INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R
bite Address Permit Number
The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3
of 6):
".L4101&«1:7=B1111111
Refer to Residential Manual Chapters 4 and 5 for more details:
Reduced Duct Surface
Calculated as the outside area of the duct. Areas must be measured and
Area:
verified by HERS rater.
Improved Duct Location:
Supply duct located in other than attic, as verified by location of registers
(does not require HERS rater verification).
Catastrophic Leakage:
Pressure pan test reading must be less than 1.5 Pascal at a house pressure
of 25 Pascal.
TXV:
Access cover required to facilitate verification.
Infiltration Reduction:
Infiltration is measured without mechanical ventilation operating.
Mechanical ventilation is required for very tight house construction when
credits for infiltration reduction using diagnostic testing are beng used for
achieving compliance. These very tight houses are defined as those with
SLA of less than 1.5. The compliance documentation (CF -1 R) will contain
the measured CFM target value from a blower door test at 50 Pascal
pressure difference that represents this SLA of 1.5. Mechanical ventilation
is also required if the builder chooses to design the building to use
mechanical ventilation and claims a credit for infiltration below an SLA of
3.0. The compliance documentation (CF -1 R) will contain the measured
CFM target value that represents this 3.0 SLA. If the builder claims credit
in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and
the actual measured SLA is 1.5 or greater, then mechanical ventilation is
not required. If the SLA in this case were below 1.5, then mitigation (such
as mechanical ventilation) would be required.
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 18 of 45
(HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I
PROJECT NAME DATE
Tradition Village Plan 16 5/31/01
SYSTEM NAME FLOOR AREA
HVAC -1 1,230
Number of Systems
1
Heating System
Output per System
88,000
Total Output (Btuh)
88,000
Output (Btuh/sqft)
71.5
Cooling System
Output per System
50,500
Total Output (Btuh)
50,500
Total Output (Tons)
4.2
Total Output (Btuh/sqft)
41.1
Total Output (sgft/Ton)
292.3
Air System
CFM per System
1,600
Airflow (cfm)
1,600
Airflow (cfm/sgft)
1.30
Airflow (cfm/Ton)
380.2
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 of 69.4 of
Outside Air
0 cfm
Supply Fan
1600 cfm
69.4 OF
11.0 / 77.6 of
OutsideA
0 cfm
74.6/59.9 of
.—�
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
I CFM
I Sensible
89
21,932
4,886
402
21,560
0
1,097
1,078
0
0
0
0
0
0
0
0
0
1,097
1,078
24,125 4,886 23,716
LENNOX HS21-048-1P 41,598 0 88,000
Total Adjusted System Output 41,598 0 J 88,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am
69.4 of 121.0 of
Heating Coil
74.6 / 59.9 of 74.6 / 59.9 of
k Return Air Ducts Y
50.2/49.1OF
Supply Fan Cooling Coil
1600 cfm
Return Air mr.fin
Supply Air Ducts
120.4 of
ROOMS
70.0 of
Supply Air Ducts
50.9 / 49.4 of
43.1% R.H. ROOMS
74.0 / 59.7 of
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:20 of 45
0
•
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ::1
PROJECT NAME DATE
Tradition Village Plan 1B 5/31/01
SYSTEM NAME FLOOR AREA
HVAC -2 1,463
Number of Systems
1
Heating System
Output per System
88,000
Total Output (Btuh)
88,000
Output (Btuh/sgft)
60.2
Cooling System
Output per System
57,000
Total Output (Btuh)
57,000
Total Output (Tons)
4.8
Total Output (Btuh/sgft)
39.0
Total Output (sgft/Ton)
308.0
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
1.37
Airflow (cfm/Ton)
421.1
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 of
Outs
0 cfm
69.3 OF
69.3 of
Supply Fan
2000 cfm
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
1,879
35,108
6,106
710
30,184
0
1,755
1,509
0
0
0
0
0
0
0
0
0
1,755
1,509
38,618 6,106 33,202
LENNOX HS21-060-1P 40,883 8,203 88,000
Total Adjusted System Output 40,883 8,203 1 88,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
-.I(:5 (Airstream I emperatures at I Ime OT Flea
69.3 of 110.60F
Heating Coil
Return Air Ducts
Supply Air Ducts
109.9 of
ROOMS
70.0 of
vULINU 5Y5I LM lJbY(;HKUMt I KICS (Airstream I emperatures at I Ime OT GOOnng reaK)
111.0/77.6OF 74.8/62.7OF 74.8/62.7OF 55.6/54.7OF
Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 56.4 / 55.0 of
2000 cfm 52.9% R.H. ROOMS
74.8/62.7 of 74.0 / 62.5 of
Return Air Ducts
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 21 of 45
0
•
WAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Tradition Village Plan 1B 5/31/01
SYSTEM NAME FLOOR AREA
HVAC -3 608
Number of Systems
1
Heating System
Output per System
35,000
Total Output (Btuh)
35,000
Output (Btuh/sgft)
57.6
Cooling System
Output per System
23,400
Total Output (Btuh)
23,400
Total Output (Tons)
2.0
Total Output (Btuh/sqft)
38.5
Total Output (sgft/Ton)
311.8
Air System
CFM per System
800
Airflow (cfm)
800
Airflow (cfm/sgft)
1.32
Airflow (cfm/Ton)
410.3
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 OF 69.2 OF
itside Air
0 cfm
Supply Fan
800 cfm
69.2 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
495
11,004
1,522
318
13,390
0
550
669
0
0
0
0
0
0
0
0
0
550
669
12,105 1,522 14,729
LENNOX HS26-024-2P 18,885 1,632 35,000
Total Adjusted System Output 18,885 1,632 35,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 Jan 12 am
pm
69.2 of 110.3 of
Heating Coil
Return Air Ducts
11.0/77.6 OF 78.6163.9 OF 78.6/63.9 OF . 56.5/55.3 OF
Outside
0 cfm
78.6/63.9 of
Supply Fan Cooling Coil
800 cfm
Return Air Ducts
Supply Air Ducts
109.5 of
ROOMS
70.0 OF
Supply Air Ducts
57.1 / 55.5 of
45.7% R.H. ROOMS
78.0 / 63.7 of
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 22 of 45
ROOM LOAD SUMMARY
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 23 of 45
PROJECT NAME
Tradition Village Plan 1B
DATE
5/31/01
.SYSTEM
NAME
HVAC -1
FLOOR AREA
1,230
IROOM LOAD SUMMARY
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
MasterSuite/Bedroom 2
Master Suite/Bedroom
1
891
21,932
4,886
891
21,932
4,886
402
21,560
.
PAGE TOTAL F 891 21,932 4,886 402 21,560
TOTAL 891 21,932 4,886 402 21,560
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 23 of 45
0
1�
F
ROOM LOAD SUMMARY
PROJECT NAME
Tradition Village Plan 113
DATE
5/31/01
SYSTEM NAME
HVAC -2
FLOOR AREA
1,463
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Gllry/Liv/Din/Kit/Lndr/
—Uffry ivin i n r w
r
1
1,879
35,108
6,106
1,879
35,108
6,106
710
30,184
PAGE TOTAL 1,879 35,108 6,106 710 30,184
TOTAL 1,879 35,108 6,106 710 30,184
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:24 of 45
ROOM LOAD SUMMARY
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:25 of 45
PROJECT NAME
Tradition Village Plan 113
DATE
5/31/01
.SYSTEM
NAME
HVAC -3
FLOOR AREA
608
IROOM LOAD SUMMARY
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Guest House
Guest House
1
495
11,004
1,522
495
11,004
1,522
318
13,390
.
PAGE TOTAL 1 495 11,004 1,522 11 318 13,390
TOTAL 495 11,004 1,522 318 13,390
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:25 of 45
ROOM HEATING PEAK LOADS
Project Title Date
• Tradition Village Plan 1B 5/31/01
Room Information Design Conditions
Room Name MasterSUite/Bedroom 2 Time of Peak Jan 12 am
Floor Area 1,230 Outdoor Dry Bulb Temperature 26°F
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
•
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Sunair NonMtl Tinted
Sunair NonMtl Tinted
Slab -On -Grade
1,230.0
X
X
X
X
X
X
X
x
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
X
0.0280
X
X
X
x
X
x
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1,516
844.8
0.0592
44.0
2,201
108.2
0.4600
44.0
2,190
64.0
0.4800
44.0
1,352
perimeter 110.0
44.5
4,895
items snown with an astehsK (-L.;52.) denote conduction through an interior surface to another room. Page Total:Infiltration: x 1.064 x 1230 x 9.90 x 1.00 /60 x ® = 9,407it Sensiblemg rea Ceiling Height
Fraction
101 TOTAL HOURLY HEAT LOSS FOR ROOM 21,560
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 26 of 45
ROOM HEATING PEAK LOADS
Project Title
Tradition Village Plan 1B
Date
5/31/01
Room Information Design Conditions
Room Name GIIry/Liv/Din/Kit/Lndr/Pvidr
Time of Peak Jan 12 am
Floor Area 1,463
Outdoor Dry Bulb Temperature 26°F
Indoor Dry Bulb Temperature 70°F
0.0280
0
Conduction
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Sunair NonMtl Tinted
Sunair NonMtl Tinted
Area
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
U -Value
X
X
x
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
1,463.0
0.0280
44.0
1,803
939.7
0.0592
44.0
2,448
188.6
0.4800
44.0
3,983
220.7
0.4600
44.0
4,467
perimeter 125.0
44.5
5,562
items snown witn an astensK (I-) cenote conauction mrougn an interior surrace to anotner room. Page Total: I 18,2631
Infiltration: I 1.00 x 1.064 x 1,463 x 1 g10.9 x 1.00 / 60x = 11,920
c e u e it Sensible Area Calling Height ACH
Fraction
• TOTAL HOURLY HEAT LOSS FOR ROOM 30,184
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:27 of 45
ROOM HEATING PEAK LOADS L 7
Project Title Date
Tradition Village Plan 113 5/31/01
Room Information Design Conditions
Room Name Guest House Time of Peak Jan 12 am
Floor Area 608 Outdoor Dry Bulb Temperature 26 OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,119
Infiltration: 1.00 x 1.064 x 608 x E 9.00 x 1.00 / 6G1 x
c e u eAir Sensible Area Ceiling Height ACHpT
Fraction
lei TOTAL HOURLY HEAT LOSS FOR ROOM 13,390
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 28 of 45 7771
608.0
X
X
X
X
x
X
X
x
x
x
x
x
x
X
X
X
X
X
x
X
x
x
X
x
X
X
X
x
X
x
X
x
X
x
X
x
X
X
X
0.0280
X
X
x
x
X
X
X
X
x
X
x
X
x
X
x
X
x
x
X
x
X
X
X
x
X
x
X
X
X
x
X
x
x
X
x
x
X
X
x
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
749
771.0
0.0592
44.0
2,009
47.0
0.4600
44.0
951
56.0
0.4800
44.0
perimeter 95.0
44.5
4,228
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,119
Infiltration: 1.00 x 1.064 x 608 x E 9.00 x 1.00 / 6G1 x
c e u eAir Sensible Area Ceiling Height ACHpT
Fraction
lei TOTAL HOURLY HEAT LOSS FOR ROOM 13,390
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 28 of 45 7771
RESIDENTIAL ROOM COOLING LOAD SUMMARY
• Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name Master Suite/Bedroom 2
Design Indoor Dry Bulb Temperature: 740F
Design Outdoor Dry Bulb Temperature: 1120F
Design Temperature Difference: 38°F
Conduction Area U -Value DETD Btu/hr
•
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Sunair NonMtl Tinted
Sunair NonMtl Tinted
X
55.0
34.6
38.0
38.0
1,894
1,731
1,891
1,167
1. Design Equivalent Temperature Difference (DETD) Page Total 6,684
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
1
(South)
2
(South)
3
(South)
4
(West)
5
(West)
6
(West)
7
(West)
8
(West)
9
(West)
10
(West)
( 16.0
X2)
X
X
X
X
x
X
x
x
X
1 +
1 +
Al +
1 +
1 +
1 +
1 +
1 +
1 +
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
x
X
x
0.568
=
=
=
=
=
=
=
=
-
=
136
( 32.0
0.0
32)
0.568
273
( 16.0
0.0
32)
0.568
136
( 0.0
2.0
73)
0.568
83
( 0.0
2.0
73)x
0.568
83
( 0.0
2.0
73)
0.568
83
(-0.0
35.2
73)
0.568
1,459
(-0.0
3.0
73)
0.568
124
( 0.0
16.0
73)
0.568
663
( 0.0
32.0
73)
0.568
1,326
Sched. Page Total a,3ss
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,230 x 0.000 Watts/sqft x 3.413 Btuh[Watt = 0
Occupants 1.00 x 1,230 x 25 Btuh/OCC. / 250 sqft/occ. = 1,255
Receptacle 1.00 X 1,230 x 0.200 Watts/sqft x 3.413 Btuh/Watt = 840
Process 1.00 x 1,230 X 0.000 Watts/Sgft X 3.413 Btuh/Watt = 0
Infiltration: [ 1.00 X 1.064 X 1,230 X 9.80 X1.00 60] 38 = 8,124
Sc e u e r ens a Area elf ng e g C p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,932
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1,230 x 225 Btuh/OCC. / 250 sgft/occ.= 1,107
Receptacle 1.00 X 1,230 x 0.000 Watts/Sgft x 3.41 Btuh/Watt = o
Process 1.00 x 1,230 x 0.000 Watts/S3.41J,Btuh/Watt = 0
Infiltration: [ 1.00 X 4,77 x 1,230 X 9.80 x 1.00 / 60] 0.00394 = 3,779
Sce u e Ali Lae Area ening Height ICC pW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,886
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 29 of 45
RESIDENTIAL ROOM COOLING LOAD SUMMARY
• Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name Master Suite/Bedroom 2
•
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
740F
112°F
3$°F
Conduction Area U -Value DETD 1 Btu/hr
X =
X =
X =
X =
X =
X =
X =
X =
X =
1. Design Equivalent Temperature Difference (DETD) Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
(West)
( 0.0
(
(
(
(
(
(
(
(
x
x
X
x
x
x
x
X
X
1
+
+
+
+
+
+
+
+
+
16.0
X
x
X
X
X
X
X
x
X
73)
x
)X
)x
)X
)X
)X
)X
)x
)x
0.568
=
=
=
=
663
Sched. Page Total ss3
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,230 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Occupants 1.00 X 1,230 X 255 Btuh/occ. / 250 sgft/occ. = 1,255
Receptacle 1.00 X 1,230 x 0.200 Watts/sgft x 3.413 Btuh/Watt = 840
Process I� 1.00 x 1,230 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: I 1.00 X"1064 x 1,230 x g g80 x 1.00 / 60] Q 38 = 8,124
c e u e r ens a Area e n e C
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,932
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 1,230 x 225 Btuh/occ. / 250 sgft/occ.= 1,107
Receptacle 1.00 X 1,230 X 0.000 Watts/sgft X 3.41 BtuhNVatt = 0
Process 1.00 X 1,230 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: x 4,77 x 1,230 x 9.80 x 1.001/ 60] 0.00394 = 3,779
c e u e r a en Area Ce ng e g pW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,886
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 30 of 45
RESIDENTIAL ROOM COOLING LOAD SUMMARY
•Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name Gllry/Liv/Din/KitfLndr/Pwdr
•
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
740F
112°F
3$°F
Conduction Area U -Value DETD 1 Btu/hr
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Sunair NonMtl Tinted
unair NonMtl Tinted
939.
220. i
0.0280
0.0592
0.4800
0.4600
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
12
(North)
13
(North)
14
(North)
15
16
(North)
(East)
17 abv
18
(East)
(East)
19 abv
(East)
20
(East)
21 abv
(East)
55.0
34.6
38.0
38.0
Page Total
SC
2,253
1,925
3,440
3,858
11,476
Btu/hr
0.0
x
x
XEl
x+
X
x
x
X1
x
X
1
+
+
+
+
+
+
+
+
+
38.6
X
X
X
X
X
X
X
X
X
x
15)
X
X
X
X
x
X
x
x
x
0.568
=
=
=
=
=
=
=
=
-
=
329
0.0
1
16.0
15)
0.568
136
0.0
32.0
15)
0.568
273
0.0
16.0
15)
0.568
136
0.0
32.0
73)
0.568
1,326
0.0
1
6.0
73)
0.568
249
0.0
1
32.0
73)
0.568
1,326
0.0
6.0
73)
0.568
249
0.0
1
32.0
73)x
0.568
1,326
0.0
1
6.0
73)
1 0.568
249
Sched. Page Total 6,668
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,463 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Occupants 1.00 X 1,463 X 255 Btuh/OCC. / 250 sgft/OCc. = 1,492
Receptacle 1.00 X 1,463 x 0.200 Watts/sgft x 3.413 Btuh/VVatt = 999
Process 1.00 x 1,463 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: 1.00 x 1.064 X 1,463 x g 1 944 x 1.00 60] Q 38 = 10,295
c e u e r ens a rea e n le
ICC
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,108
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1,463 X 225 Btuh/OCC. / 250 sgft/occ.= 1,317
Receptacle 1.00 X 1,463 X 0.000 Watts/sgft X 3.41 Btuh/Waft = o
Process 1.00 x 1,463 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: [ 1.00 x 4,77 X 1,463 x g 10944 x 1.00 60] QOt00394 = 4,789
Sc e u e r Latent rea Ce n e
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,106
EnergyPro 3.0 By EnergySoft User Number: 3666 Job Number: Page: 31 of 45
0
•
i
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
G Ilry/Liv/Din/Kit/Lndr/Pwdr
74°F
112°F
3$°F
Conduction Area U -Value DETD 1 Btu/hr
X =
X =
X =
X =
X =
X =
X =
X =
X =
1. Design Equivalent Temperature Difference (DETD) Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
22
(East)
23
(East)
24
(East)
25
(East)
26
(South)
27
(South)
28 abv
(South)
29
(South)
30 abv
(South)
31
(South)
6.0
X73)
x
X
X
X
x
X
X
x
X
+
+
+
+
+
+
+
+
+
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
x
0.568
=
=
=
=
=
=
=
=
-_
=
714
6.0
1
Al
16.0
73)
0.568
714
0.0
1
24.0
73)
0.568
995
0.0
24.0
73)
0.568
995
0.0
1
22.0
32)
0.568
400
0.0
1
16.0
32)
0.568
291
0.0
1
3.7
32)
0.568
67
0.0
1
32.0
32)
0.568
581
0.0
1
7.3
3)
0.568
133
0.0
1
16.0
32)
0.568
291
Sched. Page Total 5,180
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,463 x 0.000 Watts/sgft x 3.41 BtuhlWatt = 0
Occupants 1.00 x 1,463 x 255 Btuh/OCC. / 250 Sgft/OCC. = 1,492
Receptacle 1.00 x 1,463 x 0.200 Watts/sgft x 3.413 Btuh/Watt = 999
Process 1.00 X 1,463 X 0.000 Watts/sgft X 3.413 Btuh/Waft = 0
Infiltration:1.00 X 1.064 x 1,463 x g 109 X 1.00 / 60] 0 38 = 10,295
c e u e r ens a rea e n ie
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,108
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1,463 x 225 Btuh/OCC. / 250 sgft/OCC. = 1,317
Receptacle 1.00 x 1,463 X 0.000 Watts/sgft X 3.41 Btuh/Vllatt = 0
Process 1.00 x 1,463 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0
Infiltration: [ 1.00 X 4,77 X 1,463 X 10.44 X 1.00 / 60] 0.00394 = 4,789
Sc e u eAir Latent Area cening Heightpyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,106
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 32 of 45
0
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
G Ilry/Liv/Din/Kit/Lndr/PWdr
74°F
112°F
3$°F
Conduction Area U -Value DETD 1 Btu/hr
X
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
32 abv
Page Total
SC
Btu/hr
(South)
( 0.0
(
(
(
(
(
(
(
(
(
x
x
x
x
x
x
x
x
x
X
1
+
+
+
+
+
+
+
+
+
+
3.7
X
X
X
X
X
x
X
X
X
x
32)
x
X
)x
)x
)x
)x
)X
)x
)X
)x
0.568
=
=
=
=
=
=
67
—)
Sched. Page Total s7
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,463 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Occupants 1.00 X 1,463 x 255 Btuh/OCC. / 250 sgft/occ. = 1,492
Receptacle 1.00 X 1,463 x 0.200 Watts/sgft x 3.413 Btuh/Watt = 999
Process 1.00 x 1,463 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: 1.00 x 1.064 X 1,463 X 10.44 X 1.00 60] 38 = 10,295
�e u e r ens a Area a ng e g p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,108
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1,463 x 225 Btuh/OCC. / 250 sgftlocc.= 1,317
Receptacle 1.00 X 1,463 x 0.000 Watts/sgft x 3.41 BtuhNVatt = 0
Process 1.00 x 1,463 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: [ 1.00 x 4.771 x 1,463 x 10.44 x 1.00 / 60] QOtON0394
c e u e lr Lateen rea CeTflno He—IgTi AC
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,106
EnergyPro 3.0 By Energysoft User Number: 3665 Job Number: Page: 33 of 45
0
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Guest House
78OF
112°F
340E
Conduction Area U -Value DETD 1 Btu/hr
X
X
X
X
X
X
X
X
X
51.0
=
=
=
=
=
=
=
=
=
868
30.6
1,397
34.0
735
34.0
914
7
(South)
8
(South)
9
(South)
10
(West)
2.0
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
1
(East)
2
(East)
3
(East)
4
(East)
5
6
(East)
(East)
7
(South)
8
(South)
9
(South)
10
(West)
Page Total 3,s1a
SC Btu/hr
0.0
xX
X
x
x
X
x
x
x
X
X
+
+
+
+
+
+
+
+
+
X
X
x
X
X
X
X
x
X
73)
X
X
X
X
X
X
X
X
X
X
0.568
=
=
=
=
=
=
=
=
_-
=
83
0.0
1
Al
2.0
73)
0.568
83
0.0
2.0
73)
0.568
83
0.0
1
2.0
73)
0.568
83
0.0
1
2.0
73)
0.568
83
0.0
1
2.0
73)
0.568
83
0.0
1
16.0
32)
0.568
291
0.0
1
32.0
32)
0.568
581
0.0
1
16.0
3)
0.568
291
0.0
1
24.0
73)
0.568
995
Sched. Page Total 2,s55
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 608 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Occupants 1.00 X 608 X 245 Btuh/OCC. / 250 sgftlocc. = 596
Receptacle 1.00 X 608 X 0.200 Watts/sgft X 3.413 Btuh/Watt = 415
Process 1.00 x 608 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: _ 1.0o X 1.064 X 608 X 9.00 X 1.00 / 60] 34 = 3,300
ceue r Sensible rea Celt ng e g p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,004
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 608 x 155 Btuh/OCC. / 250 sgft/OCC. = 377
Receptacle 1.00 x 608 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0
Process 1.00 x 608 x 0.000 Watts/sgft x 3.41J,Btuh/Watt = 0
Infiltration: [ 1.00 x 4,77 X 608 X 9.90 X 1.00 / 60] �tO0263
ceue r Latent Area Calling e C N
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,522
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 34 of 45
0
E
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Tradition Village Plan 1B 5/31/01
Project Title Date
Room Name Guest House
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
78OF
112°F
340E
Conduction Area U -Value DETD 1 Btu/hr
U
1. Design Equivalent Temperature Difference (DETD) '
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
Page Total 0
SC Btu/hr
Sched. Page Total 124
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 608 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Occupants 1.00 x 608 X 245 Btuh/occ. / 250 sgftlocc. = 596
Receptacle 1.00 X 608 X 0.200 Watts/sgft X 3.413 Btuh/Watt = 415
Process 1.00 X 608 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: 1.0o x 1.064 X 608 X 9.00 X 1.00 / 60� 34 = 3 300
c e u e r ens a Area a ng e g c p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,004
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 35 of 45
Sched.
,
Latent Gain
Frac.
Area
Heat Gain
Btu/hr
Occupants
1.00
X
608 x
155 Btuh/OCC.
/ 250 sgft/occ.=
377
Receptacle
1.00
x
608 x
0.000 Watts/sgft
x 3.41 Btuh/Watt
= o
Process
1.00
x
608 x
0.000 Watts/sgft
x 3.41 Btuh/Watt
= 0
1.00
Infiltration: Lc he
X 4,77
Ti Ca an
x 608
Area
X 9.00 x 1.00
Ce -Ming Reg
/ 60]
u e
Fraction
pW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,522
EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 35 of 45
0
E
GAS FURNACES
6400 H
ENGINEERING DATA MERIT 80T" SERIES
Up-Flow/Horizontal
AFUE - 80.0%
=•� l Input - 44,000 to 110,000 Btuh (12.9 to 32.2 kW)
Add-on Cooling - 1 to 4 Tons (3.5 to 14.1 kW)
j CEIR,cEO
Bulletin No. 210278
June 2000
UP -FLOW
POSITION
pE51G,y
�FNI'IFIEO
Typical Applications
640 UH -7
Unit Type _T
G - Gas Furnace
Series
40 - Merit 80%
Configuration
UH - Up-Flow/Horizontal
/,///'00/
POSITION
Attic Installation
With cooling coil and electronic air cleaner
1- 045X
Low NO, - Units meet California
Nitrogen Oxides standards
Nominal Gas Heat -input
045 - 44,000 Btuh (12.9 kW)
070 - 66,000 Btuh (19.3 kW)
090 - 88,000 Btuh (25.8 kW)
110 - 110,000 Btuh (32.2 kW)
tpCabinet Width
A - 14-1/2 in. (363 mm)
B - 17-1/2 in. (445 mm)
C - 21 in. (533 mm)
Nominal Add -On Cooling Capacity
24 - 2 tons (7.0 kW)
36 - 3 tons (10.6 kW)
48 - 4 tons (14.1 kW)
r Evaporator coils with the same letter designation will physically match the furnace.
NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. 02000 Lennox Industries Inc.
Sent By: LENNOX IND INC; 909 590 9897; Apr -17-01 9:31AM; Page 5
E
•
Model No.
GWUH4&k- 5 04WH MA -M G40U -368490 G40UH 488-080
Model No. -'-X- Models
7=0utp-tslBo,
G40UPrW-045X G40UH.38A470X -- - - G40UM438-OU
(kW)
44.000 (12.9)"- 66.000 (19.3) 88.000 (25.8)
uh (kW)
.000 (10.5) 54,100 (15.6) 72.100 (21.1)
AAFUE
80.0%
Callfum)ia S"aaunal Etrrc.-iera:y
74.2% 74.8% 1 75.7% 75.31.
High static (AGAICGA) - in. w.g. (Pa) �-
.50(124)
Flue connection - in. (mm) round
4 (102)
Gas pipe size IPS - In. (mm)
112 (12.7) -
Temperature rise range - °F (°C)
35 - 65 (19 - 36) 40 - 70 (22 - 39)
Blower wheel nom. dlemeter & width - in. (mm)
10 x 7 (254 x 178) 10 x 8 (254 x 203) 10 x 10 (254 x 254)
Blower motor output - hp (1N)
116 (149) " r— 1/3(249) 1/2(373)
Tons (kW) of add-on cooling
1 -2 (3.5 • 7.0) 1 .3 (3.5. 10.6) 2 - 4 (7.0 -11.1)
Shipping weight - lbs- (Icg) 1 pxkago
121 (55) 132 (60) 148 (86) 153 (69)
F.lechical chancierlsitcs
120 volts - 60 hertz - 1 phase (less than 12 amps)
Q] Matching C33 (u -flow cased) /
C�H33 (hottzontal) Cols
C33.18A-2F, C33 -24A -2F, C33 -30A -2F,
C33 -36A -2F, C33 -38A -2F, 0133-18A-217,
CH33.24/3OA-2F, CH33-36A-2F
C332Gt-217, f W08 2F, C333684F.
C3338B-ZF, C33A28-2F, C3348t3-2F,
CH33_365.2F G •2F, CH32-A4/A86.217
ttiP�3Q1�Fi�L A>FC _RnERBD::
Air Filter and Rack Kit
No. and size of fllt@m - in. (mm)
Horizontal (end)
871-95 • (1) 14 x 25 x 1 (356 x 635 x 25) 871.56 - (1) 18 x 25 x 1 (457 x 635 x 25)
Side Ratum
Single 44J22 or Ten Pods (68x83) - (1) 16 x 25 x 1 (408 x 635 x 25)
EZ Filter
Base-----
Catalog Number - Shippbg Wt - Ibs. (kg)
73P55 - 6 (3) 73P56- 7 (3)
Dimensions - H x W x D - in. (mm)
No. & size of firmr (field pntsvided) - it, (mm)
4 x 14-114 x 28-5/8 (102 x 362 x 727) 4 x 17-518 x 28-5/3 (102 x 446 x 727)
_ ........................ _ .......6 _.._ ._.......
14 x 25 x 1 (35x635 x 25) 16 x 25 x 1 (406 x 635 x 25)
M High Attitude Pressure Switch Kit
56L32 49L90
Hor¢orffal Support Frame KA - Shipping Weight - lbs. ft.)
5&N8 — 18 lbs. (8 kg)
LPG1Propane Kit
432,60
Twinning Kit
15L38
*Nw%al Fuc# to ation OfxwLy owed an UOE tate pwceatees am wmra g to F I C tMg regtw"m. lautea crnazom aysmrn mzV for non-weena®d umwow
NOTE - Filters and Droveerona for mounang ars na tumishad and must be fleld provided
iM The same C33 uncased models match the furnaces ahme but requia an opoanei adaptor hese or field fabricated transmon. See C33 coil tudletin for additional itfmmsoart.
"0 stoqutrsd for yropar otte+sf)on at atQbldee over 4,500 R (1370 m).
.rll CkenaOla polyurethane frame type filar.
*Arta al Fuel Udbnaon t3 =W- y based on DOE to ptocedums and accardiT lo FTC hbeintt reSAdstorm. tedetod oanivatioir Nxtsm raft for nw-%eWwrUed nimacm
NOTE - Fitters and provisions for mounting are not 1u Ishad and muni be Bald provided.
M The earnte C33 un cased modals maid" tete (I/mac" sttttwn but nqulm an opLkrW adaptor bass or NW falalarcxl transition. Sea C33 tap h9adn for additional Wormadon.
,7) Required for proper operaiion at aMtudesc over 4-100 A. (1370 m).
Co Ci mrable potyurethyna frame type Mar.
f l Rue awr*ceen en rte unit Is 4 In. (102 mm) diameter. Most eppkaonm v4 require 9 h. 1127 mml verllrg and field mvpiad 4 x Sit. (102 x 127 mm) adepror. SeeVv" ➢r01ae
h ilia kteonoefon Irueetadprue br denied irdwamon,
r arn
�T)nxO m .iwQe RA13 RuI Bono or 11 MC and SW mW vols WM err 10W regA tfrox to of 1800 CM (850 ua) or weeoar. Sea Blw�ar Paebrrtaew Tahiec *0 pe4ti-
GOUH / Page 4 Do.
0
Moddf trio
C40UH-48'110 G4CUH48r_135
, G40JH40tr114
C4GtJH$0049 I G4WH-00D-166
Input - 13TUh (W)
1
)a 9. }
Aput • Bfuh
30.0%
-..
California Seawnal Effitctetxy
15.7% 76.0%.6
High s ( - In. w.g.
1 ,JX
Flue oonnecdon - in. (mm rou
4 ( t
4 0021
g)4 j1 02)
Gas pipe size I - In. (mm)
emperature rise range - ° (*C)
*9
40 - 70 ( ) - 44}
(1 -
rwneel nam. ala. math - In. (mm)
lU x 1u 254 xZ54)
11-11d
x x
!Ower motor oudtxrt - hP (W)
1/2(373)
314 (5W)
)ons
Torts ( of ado -on cooAng
+ 7. -17.6+)
ShIpOng welg t - lbs. (g) 1 package
169 ( ) t (
1
( 01 (91)
aracYensties
JCH3336C-2F,
v
hertz - phase less an amps
u cis
CH33 (hottzonrat)
,-
CH33-48C-2F, CH33,54MC_2F
3 9F, .6213-2F
CH33.600.217, C143362L12F
=iDf!l-:M1tS1R'S&�ilt27t�tR>99ct87C>fr7dti.
M Ar Flliar and Ra& tort HoftzontW ( 117 - ( x 25 x 1- -
Number and sine of t$P1s -in. (mm) m Sing or Ten Pack
:...........- -
7x -635X - x ' x , (b3b• x . x
(66KG3) - 1 16 x 25 x i x 635 x 26)
Catalog NUnVXW - Shipping W. - . (
- 1
F1 Fltnx
Bale
Dimensions - H x W x - in. mm
4 z 21-518 x 28-5/8 z 548 x
x x x x
stze at Mer ( - in. mm
x 2S x x
24x24x1(810x610x 25)
(Z High AitiludoPressure
Switch KIt
Hm=nal Support Frame KA - Shp. Wt - Iha. (lag)
Sib J16 — 18 bxs. (8
)
RAS Return Air Oasa
(12W172)
l rvpane kit45L50
vwnnux] Kit
15L38
*Arta al Fuel Udbnaon t3 =W- y based on DOE to ptocedums and accardiT lo FTC hbeintt reSAdstorm. tedetod oanivatioir Nxtsm raft for nw-%eWwrUed nimacm
NOTE - Fitters and provisions for mounting are not 1u Ishad and muni be Bald provided.
M The earnte C33 un cased modals maid" tete (I/mac" sttttwn but nqulm an opLkrW adaptor bass or NW falalarcxl transition. Sea C33 tap h9adn for additional Wormadon.
,7) Required for proper operaiion at aMtudesc over 4-100 A. (1370 m).
Co Ci mrable potyurethyna frame type Mar.
f l Rue awr*ceen en rte unit Is 4 In. (102 mm) diameter. Most eppkaonm v4 require 9 h. 1127 mml verllrg and field mvpiad 4 x Sit. (102 x 127 mm) adepror. SeeVv" ➢r01ae
h ilia kteonoefon Irueetadprue br denied irdwamon,
r arn
�T)nxO m .iwQe RA13 RuI Bono or 11 MC and SW mW vols WM err 10W regA tfrox to of 1800 CM (850 ua) or weeoar. Sea Blw�ar Paebrrtaew Tahiec *0 pe4ti-
GOUH / Page 4 Do.
0
Sent By: LENNOX IND INC;
LJ
0
C
E
909 590 9897; Apr -17-01 9:32AM; Page 6
*NOTE - 60C and 600 size units that require air vol-
umes over 1800 cfm (850 Lis) must have one of the
following:
1. Single side return air with transition, to accommo-
date 20 x 25 x 1 in. (308 x 635 x 25 mm) disposable
air fitter. Required to maintain proper air velocity.
2 Single side return air with optional RAB Return
Air Base
3. Bohan return air.
4. Return air from both sides.
S. Bottom Md one side return air.
See Blower Performance Tables for additional in-
formadon.
**Flue outlet may be horizontal but
fumece must be vented vertically
1.0 A
}�-- 8 � 9/16414)
EEB.� -:
OPTIONAL
-- ---- ---- i I 143/4
(3 6)
(406)
II II 5!R HRl
314 (19) C 314 (19)
'Bottom ReWrn
Air Opening
FRONT VIEW
3.3/4
FLUE OUTt
(TOA)
OPTIONAL-----------
EXTERMAL----------
SIDE RETURN �— 23-3/4(603 ----�
AIR FILTER KIT
(Either Side) 23 (635)
TOP VIEW
TOP VIEW
3-1/4 (83) Right 2724)IN
8-118 (206) Left 1�)
( 18-7/16 (14}
(494)
14 (358) Rig `
13-1/4 (337) Left
4-718 (124) Right
2-114(57) Left
T. _
(597)
�J)
(108) 'Bottorn Return
Air Opening
SIDE VIEW
310E RETURN
AIR FILTER KIT
(E/ither SIda)
40
C
0
-- ---- ---- i I 143/4
(3 6)
(406)
II II 5!R HRl
314 (19) C 314 (19)
'Bottom ReWrn
Air Opening
FRONT VIEW
3.3/4
FLUE OUTt
(TOA)
OPTIONAL-----------
EXTERMAL----------
SIDE RETURN �— 23-3/4(603 ----�
AIR FILTER KIT
(Either Side) 23 (635)
TOP VIEW
TOP VIEW
3-1/4 (83) Right 2724)IN
8-118 (206) Left 1�)
( 18-7/16 (14}
(494)
14 (358) Rig `
13-1/4 (337) Left
4-718 (124) Right
2-114(57) Left
T. _
(597)
�J)
(108) 'Bottorn Return
Air Opening
SIDE VIEW
cl 4WH / Page 5 ►
a
B
C
0
Model No.
In.
mm
In,
mm
In_
mm
In.
min
G40UH-24A-045
14-112
368
13-318
340
13
330
4-112
114
G40UH36A-070
14-112
368
13.318
340
13
330
4-1/2
114
G40UH368-090
17-1t2
446
16-3/8
416
i6
406
6
152
G40UH-486-090
17.112
446
16-318
416
16
406
16
152
G40Uti-48C-110
GeOUH-48C-135
211
533
19.718
454
19-112
495
7-314
197
G40UH-60C-110
-G40UH-600-135
24-1/2
622
23-3/8
548
23
584
9-1/2
241
G40UH-80D-155
cl 4WH / Page 5 ►
Sent By: LENNOX IND INC;
909 590
9897;
Apr -17-01
9:34AM;
Page
9/25
Vent TYPO TY" .,81..
Type .C.,
Sides 0 inches (0 mm) m0 fiches (0 mm)
ds (ill Inches (51 mm)
L712 inches (51
Rear 0 inches (0 mm) 0 inches (0 mm)
Rear 0 inches (0 mm)
0 inches (0 n
Top 1 inch (25 mm} 'I inch (25 mm)
WTop (1}0 Inches (0 mm)
� :_— , e __.
m0 ' es (
i n ti _,. rrc .
Front 3 niches (76 mm) 13 inches (76 rain).
0.19 (45)
1800 (850)
•
( :) OPTIONAL
RETURN
AIR -
BASE
AIR FLOW SIDE RETURN
AIR OPENINGS
1 * (Elther Side)
Qr--------- —
4 x_23 Overall)
02 (2000)
'Unit Opening (3W `18-112 (470)
----.----�—� Overall
- - -
3-114(83)
21 RAE
160C R8oC 20.1/2 (521) 314
24-1/2 (622) RAS60D T/8 (19)
27-518 (702)
FRONT VIEW (22)
SIDE VIEW
'NOTE -Both return air openings must be covered by a singla
plenum. Overall opening dimensions: 23 (584) W X 18-112 (470) H.
UP -FLOW POSITION
In, w -g• iPs)
0 (0)
HORIZONTAL
POSE ION
0.01(c)
VeM Type 7YPo B1. TYPo "C-'
Vent TYPO TY" .,81..
Type .C.,
Sides 0 inches (0 mm) m0 fiches (0 mm)
ds (ill Inches (51 mm)
L712 inches (51
Rear 0 inches (0 mm) 0 inches (0 mm)
Rear 0 inches (0 mm)
0 inches (0 n
Top 1 inch (25 mm} 'I inch (25 mm)
WTop (1}0 Inches (0 mm)
� :_— , e __.
m0 ' es (
i n ti _,. rrc .
Front 3 niches (76 mm) 13 inches (76 rain).
From (alcove) 24 inches (610 mm) 24 inches (610 mm
Front (service) 24 inches (610 mm) 7.4 inches (510 mm
Floor Combustible Combustible
Flus 1 inch (25 mrn) 6 Inch (152 mm)
NOTE At for corroustion aro rnp{Ylr at vastalon m,et Ca libdn to die
metleoas Dunned In American National Standard (fW4,Z223.1)
143m t Fuel Gas Cade or National Sid of Canada C�149.1,
& CAN/C3AP149.2-IrmaFeah Coo& fOr Gas BurnM ACplenoo .
NOTE --4n rre U.S. drat sb*V mail eanram to lie methods outhed In
siren t3Al6WXGA venting tables. American Nabonal Slarndad
(APtSl,Z1 J) National Fuel Gee Code or voikade provisions cf local
bLddixj cedes. In Canada flus slay n.m mrffinn to true medhoda
oufned M Nadonal Standard of Canada CMUCG6-149.1 and 2-
L1"1t eft side regiw 4 R (102 mm) if airgla wad vent is used on 14-1/2 in. (388 mm)
ad*.=, 2 in. (76 mm) on 17-12 K PW mn) cobirr a.
cfm (1./8)
In, w -g• iPs)
0 (0)
0.00(c)
200 (95)
0.01(c)
400 (190)
0.(13(5)
600 (285)
0.04 (10)
800 (380)
0.06 (15)
1000 (470)
0.09 (20)
1200 (665)
0.12 (30)
1400 (660)
0.15 (35)
1600 (755)
0.19 (45)
1800 (850)
0.23 (55)
:2000(945)
0.27 (65)
2200 (1040)
0.33 (80)
2400 (1130)
0.38 (95)
2600 1225)
0.44 (110)
G40UN / Page 8 ►
NOTE—Ar for mrnbhmoan and nippy air uemboon ms cabin m to
medhods outlined . Amainv+ National Mansard (AN61-=Ii
NadDr6w Fuel Gars Corin or Natlord Standard of Canada CANICCa4149.1,
& CAIWGGA-1492111eMladon Code nor Gas Bumhp ApolaxeC
N= -4n the US. M e gibing muse ainkin is me mec,orh wdned h
mi r M (3ANWAaA venting tibiae, Antown Ntitbndi 8W4Wd
(ANSI -2223.1) No" Fuel Gas Code or applca0te prwwors of bot
bullar g codes. In Canada Dia 4av ntuu mgmm In the rredlod6
outlined in Nadanal Standard Of Carwift CAM=A-149.1 end 2.
(fllins canted insWalon pamissOle oeween )adst tap or sides and birds )obis
1 r
All models -Pressure regulator ad)ustttterlt rnPy be required de-
pending on altitude. See below for pmosr pressure regulator
setting.
tlWtKotd Pressure (Outld) In. w.g. (kPa)
ALTITUDE ft. (m)
(0-1372)
45018300
(1373-1878)
5501-6500
(1677-1981)
6501-7500
(1982-2286)
kFUEL0-4500
3.5(.87)
3.3 (.82)
3.2(.80)
3.1(.77)
10.0 (2.40)
reasurs switch is facwry set, No adlitisunent necessary. Ail models use r
the f tory installed pressure switch Aorn 04500 feet (0.1370 m). Unim re-
quire a Mgh Ahitude Pressure Switch )tit 9 ul3WW at alttludes above 4500
feet (1370 m).
Order SBL32 for -045, -070 modols.
Order 49L90 for -090, -110, 135. -155 models.
OF
L'�WCu�W,
POWERSAVER21
EXPANSION VALVE SYSTEMS
11.00 to 15.75 SEER
*34,200 to 59,000 Btuh (10.0 to 17.3 M Cooling Capacity
'Mrh... oTf
CERTIFICATION APPLIES C&LY CERnnCAnON APPLIES ONLY
WHEN THE COMPLETE WHEN USED WIN PNOPEA
SYSTEM IS LISTED COMPONENTS AS USTED
WIN ANI WITH ARI
Typical Application
3 thru 5 Tons (10.6 thru 17.6 M
-DOE and ARI Certified Ratings
. FEATURES,
Applications
+ SEER'S of up to 15.75
a 3, 4 or 5 Ton (10.5, 14.1 or 17.6 kW) sizes.
• Single or three phase power supply.
• Two speed compressor staged to deliver precise cooling capacity
with minimum operating costs. Compressor operates on low
speed under light and medium loads. Switches to high speed for
heavy cooling loads.
• Vertical air discharge allows concealment behind shrubs at grade
level or out of sight on a roof.
• Matching blower powered or add-on furnace evaporator units
provide a wide range of cooling capacities and applications. See
ARI Ratings table.
• For evaporator unit data, see Coils– Blower Coil Units, this section.
• Units shipped completely factory assembled, piped and wired.
Each unit is test operated at the factory insuring proper operation.
• Installer must set condensing unit, connect refrigerant lines and
make electrical connections to complete job.
Approvals
• Rated in accordance with ARI 210/240-89.
• Sound rated in Lennox reverberant sound test room in accordance
with ARI Standard 270-84.
• Tested in the Lennox Research Laboratory environmental test
room.
Rated according to U.S. Department of Energy (DOE) test
procedures.
Condensing units and components within bonded for
grounding to meet safety standards for servicing required by
U.L., N.E.C. and C.E.C.
Units are U.L. listed and C.S.A. certified.
Equipment Warranty
• Compressor — Ten years (residential applications), five years
(non-residential applications).
• All other covered components — five years (residential), one year
(non-residential applications).
• Refer to Lennox Equipment Limited Warranty certificate
included with unit for details.
Bulletin #210051
May 1994
M+
f � f
OL i
Unit Cabinet
• Heavy gauge steel cabinet with five station metal wash process.
• Baked -on outdoor enamel paint finish provides rust and corrosion
protection.
• Compressor and control box located in separate fiberglass
insulated compartment.
• Control box is conveniently located with all controls factory wired.
• Large removable panel provides service access.
• Drainage holes are provided in base section for moisture removal.
• High density polyethylene base channels raise unit off mounting
surface away from damaging moisture.
• Non -corrosive PVC (polyvinyl chloride) coated steel wire
condenser coil guard furnished.
Two Speed Compressor
• Designed for superior efficiency at minimum operating cost.
• Two speed operation gives staging control to fit varying cooling
load requirements, extends operating life of compressor and
provides operating economy during periods of reduced loads.
During part load conditions the compressor operates in the low
speed mode.
• Operates at 1750 rpm at low speed and 3500 rpm at high speed.
• Compressor is suction coated, and hermetically sealed with
built-in solid-state motor protection from excessive current and
temperatures.
• Features vertical crankshaft, ringed valves and pistons, tuned
discharge muffler, two stage oil pump and positive venting of
lubrication system.
• Crankcase heater assures proper compressor lubrication.
• Running gear assembly resiliently suspended internally inside
case. Compressor is installed in unit on resilient rubber mounts
assuring low sound and vibration free operation.
Lennox TSC -5 Timed Start Control Module
• Provides short cycle protection with a 5 minute timed -off delay.
Has a 1 minute delay between compressor speed changes.
• Control has jumpers for a choice of normal operation (factory
setting) or 3 alternate compressor speed operating modes to
optimize comfort conditions for various climates.
• Diagnostic LED's are furnished as an aid in troubleshooting.
O The maple leaf symbol in this bulletin denotes Canadian only usage where applicable ^1994 Lennox Industries Inc.
NOTE — Due to Lennox' ongoing committent to quality, Specifications, Ratings and Dimensions subject to change without notice. •••
10
Condensing eARI Standard 2101240 Ratings Evaporator Unit ***Expansion
)Unit
'Model No. tSEER EER Cooling Total Valve
,*ARI Standard (Btuh/ (Btuh/ Capacity Unit Up -Flo Down -Flo Horizontal Kit ,.
270 SRN (bels) Watts) Watts) Btuh kW Watts Required
HS21-411
HS21-413
(7.6)
HS21-511
HS21=513
(7.8)
ivir;v
12.85
12.85
12.05
13.25
14.30
13.50
13.50
13.10
13.40
13.50
14.55
14.65
14.60
13.50
13.40
15.40
15.75
11.30
12.00
12.00
11.75
11.90
12.15
12.15
11.40
12.40
12.40
12.80_
12.55
12.30
12.65
13.65
11.80
12.65
12.70
12.75
13.60
14.00
1 11 13.75
• Rated in accordance wit
12.25
9.40
34,200
10.0
3638
- - - - CR18-51 ----
(49.126)
9.85 34,600 10.1 3513 C24-41FC/B24LB-85663H
C24-41 WFC/624 - " " "
---
10.05 35,600 10.4 3542 C23-46(FC) - - - - ----
---
10.05 35,600 10.4 3542 C24-46FC/B24 ----
10.05
9.70
9.70
35,600
10.4
3670 O **CVP10-41/EC10Q3
LB-85663H (49.126)
12.70
9.80
34,400
10.1
3510
- - - - - - - - CH24-41
3453
**CB19-41
11.80
9.40
34,400
10.1
3660
O **CVP10-31/EC10Q3
*Factory Installed
10.8
12.50
9.85
34,600
10.1
3513
I
- - - - CR 18-41 ----
---
10.85
10.85 37,400 11.0 3447 - - - - - - - - CH22-51+GSR21 V3
10.85 37,400 11.0 3447 C22-51(FC)+G21V3 CR22-51+GSR21V3 ----
12.65
12.65
9.85
34,600
10.1
3513
C23-41(FC) _ _ _ _
C23 41W(FC)
3423
HS21-411
HS21-413
(7.6)
HS21-511
HS21=513
(7.8)
ivir;v
12.85
12.85
12.05
13.25
14.30
13.50
13.50
13.10
13.40
13.50
14.55
14.65
14.60
13.50
13.40
15.40
15.75
11.30
12.00
12.00
11.75
11.90
12.15
12.15
11.40
12.40
12.40
12.80_
12.55
12.30
12.65
13.65
11.80
12.65
12.70
12.75
13.60
14.00
1 11 13.75
• Rated in accordance wit
%RI Standard 210/240; 95°F (35°C) outdoor air temperature, 80°F (27°C) db / 67°F (19°C) wb entering evaporator air with 25 h
i i.o mi or connecting rerngerant ones.
* Sound Rating Number in accordance with ARI Standard 270.
**Blower powered evaporator.
**"Kit is optional and must be ordered extra, unless shown as factory installed.
t Seasonal Energy Efficiency Ratio (Btuh/Watt).
*Furnished as standard with coil.
NOTE - B24 Blowers are not included with ratings for C24 and CR22 coils. B24 is shown for matching reference only.
NOTE - Shaded area denotes most popular evaporator coil.
-3-
(49.126)
9.85 34,600 10.1 3513 C24-41FC/B24LB-85663H
C24-41 WFC/624 - " " "
---
10.05 35,600 10.4 3542 C23-46(FC) - - - - ----
---
10.05 35,600 10.4 3542 C24-46FC/B24 ----
10.05
9.70
9.70
35,600
10.4
3670 O **CVP10-41/EC10Q3
*Factory Installed
10.15 36,000 10.5 3547 - - - - - - - - CH22-41
10.65 36,400 10.7 3418 - - - - CH22-41+GSR21 V3
10.60
36,600
10.7
3453
**CB19-41
**CB19-41
**CBH19-41
LB-53081CB (11G82)
10.60 36,600 10.7 3453 **CB19-31 **CB19-31 **CBH19-31
10.40 36,800 10.8 3538 **CB19-51 **CB19-51 **CBH19-51
10.30
37,000
10.8
3592
C22-46(FC)
- - - -
----
---10.35
*Factory Installed
---
10.35 37,000 10.8 3575 C22-41(FC) CR22-41/824 ----
10.85
10.85 37,400 11.0 3447 - - - - - - - - CH22-51+GSR21 V3
10.85 37,400 11.0 3447 C22-51(FC)+G21V3 CR22-51+GSR21V3 ----
10.85 37,400 11.0 3447 C22-41(FC)+G21V3 CR22-41+GSR21V3 ----
10.35 37,600 11.0 3633 C22-51(FC) CR22-51/B24 ----
---10.35
10.35 371'600 11.0 3633 - - - - - - - - CH22-51
11.10
38,000
11.1
3423
**CB21V-41
**CB21V-41
**CBH21V-41
LB-53081CB (11G82)
11.65 39,500 11.6 3391 !"*CB21V--51 **CB21V-51 **CBH21V-51
9.10
44,500
13.0
4890
- - - -
CR 18-51
---
----
LB -85663D (43J76)
9.65
9.65 45,500 13.3 4715 C23-46(FC) - - -
---
9.65 45,500 13.3 4715 C24-46FC/B24 ----
9.40
9.40 46,500 13.6 4947 - - - - CR18-65 - - - -
9.45 47,000 13.8 4974 - - - - CH24-51
9.50 47,500 1.3.9 5000 C24-51 FC/B24 - - - - ----
---
9.50
9.50 47,500 13.9 5000 C23-51(FC)
9.35
47,500
13.9
5080
O **CVP10-51/EC10Q4
- - - -
- - - -
*Factory Installed
9.65
48,500
14.2
5026
C23-51/65(FC)
LB -85663D (43.176)
9.65 48,500 14.2 5026 C24-65FC/B24 - - - - ----
---9.55
9.55
48,500
14.2
5079
**CB19-51
**CB19-51
**CBH19-51
LB -53081 CC (11G83)
9.65
48,500
14.2
5026
C22-46(FC)
*Factory Installed
9.70
49,000
14.4
5052
- - - -
- - - -
CH24-65
LB -85663D (43.176)
9.70
49,000
14.4
5052
C22-51(FC)
CR22-51/B24
CH22-51
*Factory Installed
10.05 49,500 14.5 4925 C22-51(FC)+G21V5 CR22-51+GSR21V5 CH22-51+GSR21V5
9.60 49,500 14.5 5156 O **CVP10-65/EC10Q5 - - - - ----
---
9.95
9.95
50,000
14.7
5025
- - - -
CH22-65
*Factory Installed
9.95
50,000
14.7
5025
**CB19-65
**CB19-65
**CBH19-65
LB -53081 CC (11G831
10.00
50,500
14.8
5050
C22-65(FC)
CR22-65/B24
- - - -
*Factory Installed
10.30 50,500 14.8 4903 - - - - - - - CH22-65+GSR21 V5
10.50
50,500
14.8
4810 ,
**CB21V-51
**CB21V-51
**CBH21V-51
LB -53081 CC (11G83)
10.45"'51;000'-1-4`9 4880 **C821V-65 *"C621V-65 ""CBH21V-65
10.40
51,000
14.9
1 4904
C22-65(FC)+G21V5
CR22-65+GSR21V5
- - - -
*Factory Installed
%RI Standard 210/240; 95°F (35°C) outdoor air temperature, 80°F (27°C) db / 67°F (19°C) wb entering evaporator air with 25 h
i i.o mi or connecting rerngerant ones.
* Sound Rating Number in accordance with ARI Standard 270.
**Blower powered evaporator.
**"Kit is optional and must be ordered extra, unless shown as factory installed.
t Seasonal Energy Efficiency Ratio (Btuh/Watt).
*Furnished as standard with coil.
NOTE - B24 Blowers are not included with ratings for C24 and CR22 coils. B24 is shown for matching reference only.
NOTE - Shaded area denotes most popular evaporator coil.
-3-
•
•
ARI RATINGS
Condensing
Unit
Model No.
'ARI Standard
270 SRN (bels)
eARI Standard 210/240 Ratings
Evaporator Unit
'Expansion
Valve
Required Kit
tSEER
(Stuh/
Waw)
EER
(Btuh/
Wim)
Cooling
Capacity
Total
Unit
Watts
Up -Flo
Down -Flo
Horizontal
Btuh
kW
`HS21-651
HS21-653
(7.8)
11.00
8.85
49,500
94.5
5593
- - - -
CR 18-51
----
---11.30
LB -85663E (43.177)
11.30
9.05
50,500
14.8
5580
- - - -
- - - -
CH24=51
11.40
9.15
52,000
15.2
5683
- - - -
CR18-65
----
---11.75
11.75
9.40
52,500
15.4
5585
- - - -
CR22-51/824
CH22-51
*Factory Installed
12.85
9.50
53,000
15.5
5579
- - - -
CR22-51+GSR21V5
CH22-51+GSR21V5
11.50
9.25
53,000
15.5
!710
C23-51(FC)
----
---
LB.85663E (43.177)
LB-85663E
11.50
9.25
53,000
15.5
5730
C24-51 FC/824
- - - -
----
---11.70
11.70
9.40
54,000
I
15.8
5745
C22-46(FC)
- - - -
----
---
*Factory Installed
*Factory
11.60
9.60
54,000
15.8
5625
0 **CVP10-65/EC10Q5
- - - -
I
---
----
11.70
11.70
0
9.40
54,500
16.0
5798
C23-51/65(FC)
- - - -
----
---
LB 85663E (43.177)
!
11.70
9.40
54,500
16.0
5798
C24-65FQB24
- - - -
CH24-65
12.00
9.50
55,500
16.3
5842
C22-51(FC)
- - - -
----
---13.00
*Factory Installed
13.00
9.85
56,000
16.4
5685
C22-51(FC)+G21 V5
- - - -
----
---12.25
12.25
9.80
56,000
16.4
5714
- - - -
CR22-65/824
CH22-65
12.15
9.50
56,500
16.6
5947
C22-65(FC)
- - - -
----
---13.00
13.00
9.75
56,500
16.6
5795
- - - -
CR22-65+GSR21 V5
CH22-65+GSR21 V5
13.00
10.05
57,000
16.7
5672
C22-65(FC)+G21V5
----
---12.85
12.85
9.70
58,000
17.0
5979
**CB19-51
**CB19-51
**CBH19-51
LB -53081 CE (321354)
12.80
9.50
58,500
17.1
6158
**CB19-65
**CB19-65
**CBH19-65
13.80
10.00
58,500
17.1
5850
**CB21V-51
**CB21V-51 -
**CBH21V-51
**C821V65
**C621V-65
**CBH21V-65
14.00
9.80
59,000
117.3
6020
t
C__
• Rated in accordance with ARI Standard 210/240; 95°F (35•C) outdoor air temperature, 80°F (27°C) db/67°F (19°C) wb entering evaporator air with 25 ft.
(7.6 m) of connecting refrigerant lines.
Sound Rating Number in accordance with ARI Standard 270.
••• Blower powered evaporator.,
••• Kit is optional and must be ordered extra, unless shown as factory installed.
t Seasonal Energy Efficiency Ratio (Btuh/1Natt).
*Furnished as standard with coil.
NOTE - B24 Blowers are not included with ratings for C24 and CR22 coils. B24 is shown for matching reference only.
NOTE - Shaded area denotes most popular evaporator coil.
-4-
\J
ELECTRICAL DATA
r-'� 1
rDISCONNECT,
SWITCH
Model No.
HS21-411
HS21-413
THSZ1=511?
HS21-513
-,H!S'651--7
HS21-653
Line voltage data - 60 hz
208/230v
1ph
208/230v
3ph
208/230v
1ph
208/230v
3ph
208/230v
1ph
208/230v
3ph
Compressor
Rated load amps
17.6
12.7
21.6
i
15.8
30.8
19.9
Power factor
.98
.90
.98
.90
.92
.90
Locked rotor amps
90.0
60.0
120.0
85.0
141.0
91.0
Condenser
Coil
Fan Motor
Full load amps
1.0
1.0
1.0
1.0
1.7
1.7
Locked rotor amps
1.9
1.9
1.9
1.9
2.9
2.9
Recommended maximum fuse
or circuit breaker size (amps)
40
25
45
35
60
45
Minimum circuit ampacity
23.0
16.9
28.0
20.8
40.2
26.6
,meter to ivationai or Lanaman tiectncai Loae manuai to determine wire, ruse ana aisconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
FIELD WIRING
DISC NE
r-'� 1
rDISCONNECT,
SWITCH
THERMOSTAT.'.
(Op onil)
SWITCH:.:
Suction Line
i L (By Others)
J
L-_
Outside
L (By Others)
J
Set
IA
Diameter
Diameter
Model No.
Model No.
A - Two Wire Power (not furnished)
i
B
in.
mm
in.
mm
B - Two or Three Wire Power (not furnished) - See Electrical Data
i
i
HS21-411
L10-65-30
30 9
C - Three Wire Low Voltage (not furnished) - 18 ga. minimum
HS21-413
C
D - Six Wire Low Voltage (not furnished) - 18 ga. minimum
LENNOX
L10-65-40
LENNOX
All wiring must conform to NEC or CEC and local electrical codes.
9.5
CONDENSING
22.2
HEATING UNIT
i
UNIT
OR
L10-65-50
50 15
-BLOWER COIL .
I
HS21 651
:.EVAPORATOR
UNIT
HS21-653
*Not available
REFRIGERANT
Length of
Liquid Line
Suction Line
Condensing
Line
Outside
Outside
Unit
Set
Lines
Diameter
Diameter
Model No.
Model No.
ft. m
in.
mm
in.
mm
HS21-411
L10-65-30
30 9
HS21-413
HS21-511
L10-65-40
40 12
3/8
9.5
7/8
22.2
HS21-513
L10-65-50
50 15
HS21 651
HS21-653
*Not available
3/8
9.5
1-1/8
28.5
'Meld tabrncate.
-5-
INLET AIR
TOP VIEW
32-1/8 34-1/16
(816)(8651� {
DISCHARGEE
ELECTRICAIR
�vNax INLETSAL
LIQUID
LINE 00
":: ',;L• INLET
SUCTION _
a , f LINE 20-3/4 (64)
l )
! ;;; sr,.;x.;•%may INLET 527
7-1/2 7-1/2 7 18-5/8
2 �(190) Imo`* (190) 2-3/4 N� (473) k6 -1116L
-►{ �21701(51) (51) 1-3/8-110 26-5/81676)
28-1/8 (714) (35) (154)
FRONT VIEW SIDE VIEW
Model No. A B
i
HS21-411-413
HS21-511-513
in. 40-7/8 4-1/2
—1
HS21-651-653
in. 44-7/8 8-1/2
mm 1140 216
INLET AIR
TOP VIEW
32-1/8 34-1/16
(816)(8651� {
DISCHARGEE
ELECTRICAIR
�vNax INLETSAL
LIQUID
LINE 00
":: ',;L• INLET
SUCTION _
a , f LINE 20-3/4 (64)
l )
! ;;; sr,.;x.;•%may INLET 527
7-1/2 7-1/2 7 18-5/8
2 �(190) Imo`* (190) 2-3/4 N� (473) k6 -1116L
-►{ �21701(51) (51) 1-3/8-110 26-5/81676)
28-1/8 (714) (35) (154)
FRONT VIEW SIDE VIEW
I•
INSTALLATION CLEARANCES — inches (mm1
%///MMMY/.%//////z'64,
NOTE -48" (1219 mm) clearance required on top of unit.
'NOTE—One side of coil may be 12 1305) inches.
—6—
E.
Model No. A B
HS21-411-413
HS21-511-513
in. 40-7/8 4-1/2
mm 1038 114
HS21-651-653
in. 44-7/8 8-1/2
mm 1140 216
I•
INSTALLATION CLEARANCES — inches (mm1
%///MMMY/.%//////z'64,
NOTE -48" (1219 mm) clearance required on top of unit.
'NOTE—One side of coil may be 12 1305) inches.
—6—
E.
t•
•
11.70 to 14.20 SEER
*18,500 to 60,000 Btuh (5.4 to 17.6 kW) Cooling Capacity
1.5 thru 5 Tons (5.3 thru 17.6 kW)
*DOE and ARI Certified Ratings
Application —The HS26 series condensing units feature extra high
efficiency with minimum operating sound levels. Units area pplicable
to expansion valve systems only. Units may be installed at ground
level or on a roof. Units are adaptable to several blower powered and
add-on evaporators providing a wide range of cooling capacities for
selective sizing and application versatility. For evaporator unit data
see tab Coils — Blower Coil Units in this section. Units are shipped
completely factory assembled, piped and wired. In addition, each
unit is test operated at the factory insuring proper operation. Installer
has only to place condensing unit in desired location, connect refrig-
erant lines and make electrical connections to complete the job.
Approvals — Condensing units have been tested in the .Lennox Re-
search Laboratory environmental test room and raied in accordance
with ARI Standard 210/240-94. In addition, units have been sound rated
in the Lennox reverberant sound test room in accordance with test
conditions included in ARI Standard 270-95. Condensing units and
components within are bonded for grounding to meet safety standards
for servicing required by U.L. and C.E.C. Units are U.L. and U.L.C. listed.
Developed in accordance with ISO 9002 quality standards.
Equipment Warranty —The compressor has a limited warranty for
ten years in residential installations and 5 years in non-residential
installations. All other covered components have a limited warranty
for five years in residential installations and one year in non-residential
installations. Refer to Lennox Equipment Limited Warranty included
with the unit for details.
Copeland= Compliant Scroll' Compressor—High efficiency compres-
sor features durability, steady uniform suction flow, constant discharge
flow, high volumetric efficiency, quiet operation and the ability to start
under any system load. Use of the scroll compressor eliminates the need
for crankcase heater, start capacitor and start relay. The compliant scroll
type compressor is a simple compression concept design consisting of
two involute spiral scrolls matched together to generate a series of
crescent-shaped gas pockets between them. During compression,
one scroll is stationary while the other
is allowed to orbit, not rotate, around
the fixed one. As this motion occurs,
gas is drawn into the outer pocket
sealing off the open passage. As the
spiral movement continues, the
pockets between the scrolls are slowly
pushed to the center of the scrolls
-while simultaneously being reduced
in volume. When the pocket reaches `
the center, the gas is now at high
pressure and is forced out of a port
located in the center of the fixed
scroll. During compression, several
pockets are being compressed simul-
taneously resulting _jn a smooth,
nearly continuous compression
cycle. Continuous flank contact,
maintained by centrifugal force, mini-
mizes gas leakage and maximizes
efficiency. The scroll compressor is
tolerant to the effects of liquid slug-
ging and contaminants. Should this
occur, the scrolls separate and allow
the liquid or contaminants to be
worked to the center and discharged. Low gas pulses during com-
pression minimize operational sound level. Motor is internally pro-
tected from excessive current and temperature. Compressor is installed
in the unit on resilient rubber mounts, assuring vibration free operation.
(Continued)
September 1996
Supersedes
April 1996
CERPRCAPON NPPUES ONLY 'SO 9002 RMST:RrO
-EN ME COMPLETE WORLD CLASS OUALI Y
SYSTEM IS USTEO
111TH ARI
UOD C UE)0L
LISTED LISTED
Typical Application
0 The maple leaf symbol in this bulletin denotes Canadian only usage where applicable 4)1996 Lennox Industries Inc.
NOTE — Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Durable Steel Cabinet - Heavy gauge galvanized steel cabinet is
subject to a five station metal wash process. This preparation results
in a per'fect bonding surface for the finish coat of baked -on outdoor
enamel. The attractive enamel finish gives the cabinet long lasting
0nrotection from rust and corrosion. Compressor and control box are
cated in a separate compartment insulated with thick fiberglass
sulation. Compartment provides protection from the weather and
keeps sound transmission at a minimum. Control box is conveniently
located with all controls factory wired. Large removable panel provides
service access. Drainage holes are provided in the base section for
moisture removal. High density polyethylene basechannels raise the
unit off of the mounting surface away from damaging moisture. Non-
corrosive PVC (polyvinyl chloride) coated steel wire condenser
coil guard is furnished.
Copper Tube/Enhanced Fin Coil - Lennox designed and fabricated
coil is constructed of precisely spaced ripple -edged aluminum fins
machine fitted to seamless copper tubes in a wrap around "U"
shaped configuration providing extra large surface area with low air
resistance. Lanced fins provide maximum exposure of fin surface to
air stream resulting in excellent heat transfer. In addition, fins are
equipped with collars that grip the tubing for maximum contact area.
Precise circuiting provides uniform refrigerant distribution. Flared
shoulder tubing connections and silver soldering provide tight, leak-
proof joints. Long life copper tubing is corrosion -resistant and easy
to field service. Coil is thoroughly factory tested under high pressure
to insure leakproof construction. Entire coil is accessible for cleaning.
Powerful Condenser Fan -Efficient direct drive fan moves large
volumes of air uniformly through the entire condenser coil resulting in
high refrigerant cooling capacity. Vertical discharge of air minimizes
operating sounds and eliminates hot air damage to lawn and shrubs.
Fan motor is inherently protected and totally enclosed for maximum
protection from weather, dust and corrosion. A rain shield on the motor
provides additional protection from moisture. Fan service access is
accomplished by removal of fan guard. Corrosion resistant PVC (poly-
vinyl chloride) coated steel wire fan guard is furnished as standard.
Hi -Capacity Drier - Furnished as standard for field installation. Drier
traps any moisture or dirtthat could contaminate the refrigerant system.
WigPressure Switch -Shuts off unit if abnormal operating conditions
cause the discharge pressure to rise above setting. Switch protects
compressor from excessive condensing pressure. Manual reset.
Low Pressure Switch -Shuts off unit if suction pressure falls below set-
ting. Provides loss of charge and freeze-up protection. Automatic reset.
4
rimed -Off Control -Timed off control prevents compressor short -
cycling and also allows time for suction and discharge pressure to
equalize, permitting the compressor to start in an unloaded condition.
Automatic reset control provides a five minute`iime delay between
compressor shutoff and start-up.
Refrigerant Line Connections, Electrical Inlets and Service Valves -
Suction and liquid lines are located inside of the cabinet and are made
with sweat connections. Fully serviceable brass service valves prevent
corrosion and provide easy access to refrigerant system. Suction valve
can be fully shut off, while the liquid valve may be backseated to
manage refrigerant charge while servicinIthe system. Suction and
liquid line service valves and gauge ports are located inside the cabinet.
A thermometer well is located in the liquid line to check the refrigerant
charge. Refrigerant line connections and field wiring inlets are all located
in one central area of the cabinet. See.dimension drawing.
OPTIONAL ACCESSORIES (Must Be Ordered Extra)
Thermostat (Optional) -Thermostat is not furnished with the unit
and must be ordered extra. See Thermostats bulletin in Accessories
section (U.S. only) and Lennox Price Book.
Refrigerant Line Kits (Optional) = Lines are available in several
lengths and must be ordered extra. See Refrigerant Line Kittable. The
refrigerant lines (suction and liquid) are shipped refrigeration clean.
Lines are cleaned, dried and pressurized at the factory and sealed.
Suction line is fully insulated. L15 line sets are stubbed at both ends.
Expansion Valve Kits (Optional) - Must be ordered extra and field
installed on some matching evaporator units. See ARI Ratings table.
Low Ambient Kit (Optional) -Condensing units will operate satisfacto-
rily down to 45°F MC) outdoor air temperature without any additional
controls. For cases where operation of the unit is required at low
ambients a Low Ambient Control Kit LB-57113SC (24H77) can be
added in the field, enabling itto operate properly down to 30°F (-1 °C).
Mounting Base (Optional) -Rugged mounting base provides perma-
nent foundation for condensing units. High density polyethylene
structural material is lightweight, sturdy, sound absorbing and will
withstand the rigors of the sun, heat, cold, moisture, oil and refrigerant.
Will not mildew or rot. Can be shipped singly or in packages of 6 to
a carton. All models use MB2-L (69J07) 32 x 34 x 3 in. (813 x 864 x 76
mm) shipping weight 15 lbs. (7 kg) each.
*Refrigerant Charge sufficient for 25 ft. (7.6 m) length of refrigerant lines.
HS26 / Page 2 ►
Model No.
HS26-018 � 'f1HS26 024f,.J
HS26-030 HS26-036
HS26-042 HS26-048
HS26-060
Net face area
- sq. ft. (m2)
Outer coil
11.9 (1.11)
11.9 (1.11)
16.0 (1.59)
16.0 (1.59)
16.0 (1.59)
18.2 (1.69)
21.6 (2.01)
Inner coil
5.5 (0.51)
5.5 (0.51)
5.6 (0.52)
13.3 (1.24)
13.3(l.24)
13.3(l.24)
20.8 (1.93)
Condenser
Coil
Tube diameter - in. (mm)
5/16(7.9)
5/16(7.9)
5/16(7.9)
5/16(7.9)
5/16(7.9)
5/16(7.9)
5/16(7.9)
No. of rows
1.48
1.48
1.36
1.86
1.86
1.75
2
Fins per inch (m)
22 (866)
22 (866)
22 (866)
22 (866)
22 (866)
22 (866)
22 (866)
Dia. - in. (mm) no. of blades
20(508)-4
20(508)-4
24(610)-3
24(610)-3
24(610)-3
24 (610) - 4
24 (610) - 4
Motor hp (W)
1/10(75)
1/6(124)
1/6024)
1/6024)
1/6(124)
1/4(187)
1/4(187)
Condenser
Fan
Cfm Qs)
2500 (1180)
2450 (1155)
3150 (1485)
3150 (1485)
3000 (1415)
3900 (1840)
4200 (1980)
Rpm
825
825
825
825
825
820
820
Watts
160
210
225
225
230
310
350
'Refrigerant - HCFC -22 charge furnished
4 lbs. 1 oz.
(1.84 kg)
4 lbs. 1 oz.
0.84 kg)
5 lbs. 1 oz.
(2.30 kg)
5 lbs. 13 oz.
(2.64 kg)
6 lbs. 11 oz.
(3.03 kg)
7 lbs. 5 oz.
(3.32 kg)
10 lbs. 8 oz.
(4.76 kg)
iquid line (o.d.) - in. (mm) sweat
3/8(9.5)
3/8(9.5)
3/8(9.5)
3/8(9.5)
3/8(9.5)
3/8(9.5)
3/8(9.5)
Suction line (o.d.) in. - (mm) sweat
5/8(16)
3/4(19)
3/4(19)
3/4(19)
7/8(22.2)
7/8(22.2)
1-1/8 (28.6)
Shipping weight - lbs. (kg) 1 package
177 (80)
185 (84)
192 (87)
221 (100)
231 (105)
274 (124)
308 (140)
*Refrigerant Charge sufficient for 25 ft. (7.6 m) length of refrigerant lines.
HS26 / Page 2 ►
FAR/ RATINGS .
Unit Size &
Model No.
"Sound Rating
Number (db)
*ARI Standard 210/240 Ratings
Cooling Cap. Total
SEER EER Unit
Btuh kW Watts
Up -Flow
Down -Flow
Evaporator Coils
Horizontal
"*Ex ansion
Valve Kit
Required
1.5 Ton
HS26-018
(74)---
(74)
18,900
5.5
12.10
10.85
1740
C26-21(FC) - - - -
- - - -
*Factory Installed
19,000 5.6 12.10 10.90 1740 C23-26(W)(FC) ---- ----
LB-85663) (26K34)
19,100 5.6 12.20 10.95 1740 C23-31(W)(FC) ----
19,300 5.7 12.30 11.05 1745 C26-26(W)(FC) ---- ----
*Factory Installed
20,000 5.9 13.00 11.40 1750 C26-31(W)(FC) ----
---
19.=00 5.7 13.00 11.55 1685 C26-26(W)(FC)+G25MV3 ----
---
20,400 6.0 13.40 12.05 1695 C26-31(W)(FC)+G25MV3 - - - - ----
20,400
18,500
18,500 5.4 11.85 10.65 1735 - - - - CR26-21
LB -85663J (26K34)
19,700 5.8 12.55 11.25 1750 - - - - CR26-31 - - - -
20,400 6.0 13.00 11.55 1765 - - - - CR26.41(N)(W)
18,800 5.5 12.40 11.20 1680 - - - - CR26-21+G25MV3 ----
19,900 5.8 13.20 11.80 1690 - - - - CR26-31+G25MV3 - - - -
18,500 5.4 11.80 10.65 1735 - - - - CH23-21
18,700 5.5 12.00 10.75 1740 - - - - - - - - ( CH23-31
19,600 5.7 12.60 11.15 11760 1- - - - CH23-41
20,200 5.9 13.00 11.45 1765 - - - - - - - - CH23:51
Btuh kW SEER EER Watts Blower Coil Units
Valve
18,900 5.5 12.15 10.90 1735 C829M-21/26 (Multi -Position)
•Factory Installed
20,200 5.9 12.85 11.55 1750 CB30M-21/26 (Multi -Position)
20,800 6.1 13.35 12.00 1735 CB30M-31 (Multi -Position)
---
19,000 5.6 12.00 . 10.70 1775 0 CVP10-26/EC10Q3 I - - - - ----
rTon24,400
6 N24
(74)
Btuh
Btuh
kW
SEER EER
Watts Evaporator Coils
Valve
22;600; 16_61 1� 2!101 1� 0:70� 2�1t15y C26-21(FC) - - - - - - - -
*Factory Installed
---
23,400 6.9 12.10 10.75 2180 C23-26(W)(FC) - - - - ----
LB -85663) (26K34)
23,800 7.0 12.25 10.90 2185 C23-31(W)(FC) - - - - - - - -
23,800
24,000 7.0 12.35 11.00 2185 C23-41(W)(FC) ---- ----
24,000 7.0 12.35 11.00 2185 C26-26(W)(FC)
•Factory Installed
25,200 7.4 12.85 11.40 2205 C26-31(W)(FC) ---- ----
25,200 7.4 13.10 11.40 2205 C26-41(FC) ----
---
25,200 7.4 13.50 11.90 2115 C26-31(W)(FC)+G25MV3 - - - - ----
25,400 7.4 13.85 12.25 2075 C26-31(W)(FC)+G21V3 ---- ----
25,400
22,200 6.5 11.70 10.40 2135 - - - - CR26-21 - - - -
LB -85663) (26K34)
7.1 12.60 11.15. 2190 - - - - CR26-31
25,000 7.3 13.00 11.40 2190 CR26 41(N)(W)
24,600 7.2 13.25 11.65 2115 - - - -CR26-31+G25MV3
22,400 6.6 11.80 10.50 2135 - - - - - - - CH23-21
23,200 6.8 12.00 10.65 2180 - - - - - - - - CH23-31
24,200 7.1 12.55 11.00 1 2200 - - - - - - - - CH23-41
25,200 7.4 13.00 11.40 2210 - - - - - - - - CH23-51
Btuh kW SEER EER Watts Blower Coil Units
Valve
23,000 6.7 12.05 10.75 2145 CB29M-21/26 (Multi -Position)
•Factory Installed
23,600 6.9 12.20 10.85 2175 + CB29M-31 (Multi -Position)
24,800 7.3 12.80 11.30 2190 CB30M-21/26 (Multi -Position)
251600 7.5 13.55 12.10 2115 CB30M-31 (Multi -Position)
25,800 7.6 14.00 12.50 2060 CB31MV-41 (Multi -Position)
23,200 6.8 11.85 10.55 2195 10 CVP10-26/EC10Q3 I - - - - I - - - -
*Rated in accordance with ARI Standard 210/240;95'F (35°C) outdoor air temperature, 80°F (27°C) db / 67°F (19°C) wb entering evaporator air with 25 ft. (7.6 m) of
connecting refrigerant lines.
'Sound Rating Number rated in accordance with test conditions included in ARI Standard 270.
•• Kit is required and must be ordered extra, unless shown as factory installed.
*Furnished as standard with coil.
NOTE - Shaded area denotes most popular evaporator coil.
HS26 / Page 3 ►
ELECTRICAL DATA
Model No.
HS26-018 ,HS267024
HS26-030
HS26-036
HS26-042
Line voltage data - 60hz
208/230v
1ph
208/230v
1ph
208/230v
1ph
208/230v
1ph
208/230v
3ph
208/230v
•"1 ph
208/230v
.3ph
460v
3ph
Rated load amps
8.4
10.3
13.5
16.0
10.3
18.0
12.5
Compressor
Power factor
0.97
0.96
0.96
0.96
0.82
0.94
'0.82
Locked rotor amps 47 56 72.5 88 77 104
88
Condenser Coil
Fan Motor
Full load amps
0.8
1.1
1.1
1.1
1.1
1.1
1.1
Locked rotor amps 1.6 2.0 2.0 2.0 2.0 2.0
2.0
Rec. max. fuse or circuit breaker size (amps)
15
20
30
35
20
40
25
*Minimum circuit ampacity
13
14
1 18
1 21.3
14
23.6
16.4
'meter to National or Canadian tlectrical Code manual to determine wire, ruse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
Model No.
Length of
Line Set Min.
Model No.
HS26-048
Suction
Line
(o. d.)
HS26-060
in.
Line voltage data - 60hz
208/230v
1ph
208/230v
3ph
460v
3ph
208/230v
1ph
208/230v
3ph
460v
3ph
Compressor
Rated load amps
23.7
13.5
7.4
28.8
17.4
9.0
Power factor 1 .97 .87 .87 .97 .85
.85
Locked rotor amps 129 99 49.5 169 123-
62
Condenser Coil
Fan Motor
Full load amps
1.7
1.7
1.1
1.7
1.7
1.1
Locked rotor amps 3.1 3.1 2.2 3.1 3.1
2.2
Rec. max. fuse or circuit breaker size (amps)
50
30
15
60
40
20
*Minimum circuit ampacity
31.4
18.6
10.4
37.7
23.5
12.4
*Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
rDISCONNECT,
SWITCH
L -(By O -hers) J
LENNOX
CONDENSING
UNIT
r-----1 rDISCONNECTI
THERMOSTAT I I SWITCH I
(Optional) (By Others)
REFRIGERANT LINE KITS
LENNOX
HEATING UNIT
OR
*BLOWER COIL
EVAPORATOR
UNIT
Contin t Ing
Model No.
Length of
Line Set Min.
Model No.
Liquid
Line
(o.d.)
Suction
Line
(o. d.)
mm
in.
mm
HS26-018
L15-26-20 20 6
3/8
_
9.5
5/8
15.9
L15-26-25 25 8
L15-26-35 35 11
L15-26-50 50 15
HS26-024
HS26-030
HS26-036
L15-41-20 20 6
3/8
9.5
3/4
19
L15-41-30 30 9
L15-41-40 40 12
L15-41-50 50 15
HS26-042
HS26-048
L15-65-30 30 9
3/8
9.5
7/8
22.2
L15-65-40 40 12
L15-65-50 1 50 15
HS26-060
*Not available
3/8
9.5
1-1/8
122.2
*Field raoncate.
A - Two or Three Wire Power (not furnished)
B - Two or Three Wire Power (not furnished) - See Electrical Data
C - Two Wire Low Voltage (not furnished) - 18 ga. minimum
D - Four Wire Low Voltage (not furnished) - 18 ga. minimum
All wiring must conform to NEC or CEC and local electrical codes.
f INSTALLATION CLEARANCES -inches (mml
NOTE -48 inches (1219 mm) clearance required on top of unit.
*NOTE -Two sides of coil may be 12 inches (305 mm).
HS26 / Page 7 ►
E
10
DIMENSIONS --inches (mm)
2
(51)
ELECTRICAL
B
INLETS \
SUCTION LINE
A
B
INLET
D
E
(HS26-018 thru 042
G
H
LIQUID
:HS26-018,
HS26-024
in.
INLET LINE
25-7/8
29-7/8
(HS26-048-060)
22-7/16
14-7/16
22-1/8
ACCESS VIEW
A
4-1/2(114) {
LIQUIDO-
LINE INLET
HS26-018 thru 042
SUCTION
LINE INLET 2 9
D
(HS26-048-060) I-(6
2-3/4 (70) F
r
1-3/8 (102) (102) 6-1/16
1) (35) E so (154)
SIDE VIEW
INLET AIR
TOP VIEW
C
DISCHARGE * AIR
INLET
a
AIR
Model No.
A
B
C
D
E
F
G
H
J
:HS26-018,
HS26-024
in.
27-7/8
25-7/8
29-7/8
12-1/4
22-7/16
14-7/16
22-1/8
2-7/8
5-1/2
mm 708 657 759 311 570 367 562 73
140
HS26-030,
HS26-036,
HS26-042
in.
30-7/8
32-1/8
34-1/16
12-3/4
26-5/8
18-5/8
28-1/8
3-7/8
7-1/2
mm 784 816 865 324 676 473 718 98
191
HS26-048
in.
34-7/8
32-1/8
34-1/16
13-3/4
26-5/8
18-5/8
28-1/8
3-7/8
7-1/2
mm1 886• 816 865 349 676 473 718 98
191
HS26-060
L
40-7/8
32-1/8
34-1/16
19-13/16
26-5/8,
18-5/8
28-1/8
3-7/8
7-1/2
473 718 98
191
NOTE - For Temperatures and Capacities not shown in tables, see bulletin -Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
HS26-018 - C26-21(FCI
rvv i C - All Values are gross capacities ano ao not incwae maoor cou oiower motor neat aeauction.
HS26 / Page 8 ►
Outdoor Air Temperature Entering Outdoor Coil
Enter-
Total
85-F (29°C)
951F (35'C)
105'1`141°C)
115°F (46°C)
Wet Air
Volume
Total
Com-
Sensible
To Total
Total
Com-
Sensible
To Total
Total
Com-
Sensible
To Total
Total
Com-
Sensible
To Total
Bulb
Temper-
Cooling
Capacity
pressor
Ratio ISM
Coaling
Capacity
pressor
Ratio IS/
Cooling
Capacity
pressor
Ratio ISM
Cooling
Capacity
pressor
Ratio (SIT)
Motor
Dry Bulb •
Motor
Dry Bulb
Motor
Dry Bulb
i
Motor
Dry Bulb
ature
Watts
5°F 80°F 85'F
Watts
75°F 80° 85°F
Watts
5°F 80°
Watts
80° 85°F
L/s
cfm
kW
Btuh
Input
kW
Stuh
Input
kW Btuh
Input
85°F
kW
Btuh
Input
5°F
4°C 7°C 9°C
24°C 27°C 29°C
24°C 27°
4°C 27°C
190
400
5.2
17,700
1170 1.68
.79 .90
1 5.0
17,200
1340
.69 .80' .92
4.9 16,600
1530
.69 .82 .93
4.7
15,900
1740
.70 .83 .95
63°F
(17.2-C)
285
600
5.6
19,200
1180
.76 .90 1.001
5.5
18,600
1350
.77 .92 1.00
5.2 17,900
1540
.781.93 1.00
5.0
17,100
1750
.80 .95 1.00
375
800
5.9
20,200
1190
.83 .98 1.001
5.7
19,500
1360
.85 .99 1.00
5.5 18,900
1550
.86 1.001.00
5.3
18,200
1760
.88 1.00 1.00
190
400
5.6
19,000
1180
.54 .65 .76
15.4
18,400
1350
.55 .66 .77
5.2 17,800
1540
.55 .67 .78
5.0
17,000
1750
.56 1.68 .80
7°F
19.4°C)
285
600
6.0
20,400
1190
.59 .73 .87
5.8
19,700
1360
.59 .74 .88
5.5 18,900
1550
.60 .76 .90
5.3
18,100
1760
.61 .77 .92
375
800
6.2
21,100
1200
.63 .81 .96
1 6.0
20,400
1370
.64 .83 .97
5.7 19,600
1550
.65 .84 .99
5.5
18,800
1760
.67 .86 1.00
71°F
190
400
6.0
20,400
1190
.42 .52 .62
5.8
19,800
1360
.42 .53 .63
5.6 19,000
1550
.42 .53 .64
5.4
18,300
1760
.42 .54 .65
(21,7°CI
285
600
6.4
21,700
1200
.43 .57 .71
6.2
21,000
1370
.43 .58 .72
5.9 20,200
1560
.44 .58 .73
5.7
19.400
1770
.44 .59 .75
375
800
6.6
22 400
1210
.45 .62 .79
6.4
21 700
1380
.a5 .63 .80
6.1 20 800
1560
.46 .6a .82
5.8
19 900
1770
.46 .66 .84
rvv i C - All Values are gross capacities ano ao not incwae maoor cou oiower motor neat aeauction.
HS26 / Page 8 ►
.0.
LTffff Marc.,
INNOVATOR' PROGRAMMABLE THERMOSTATS
1_21 SERIES 24 HOUR THERMOSTATS
For Conventional Heating/Cooling Systems Only
(Non -Heat Pump Systems)
Model No. Description Catalog No
L211201CS ......... 1 Heat/1Cool 24 Hour ........ 6SH25
L212201CS ......... 1 Heat/2 Cool 24 Hour ........ 691-126
A2000 -ROS ..... Outdoor Temperature Sensor .... 69H27
•Automatic Or Manual Changeover
*Built-in Time Delays
• Large Easy -to -read LCD Readout
*Actual Time And Temperature in OF or °C for alternating inside
and outside temperature readout (with optional outdoor
temperature sensor)
•Two Stage Cooling Model features low or high speed cooling
operation indicators
•Check Filter Indicator flashes at preset interval
*System Selector Switch (Off -Heat -Cool -Auto)
•Fan Switch (On -Auto)
*Indicator Lights ("Amber" light indicates system operating,
"Green" light indicates night period energy'savings)
•Solid-state Electronic Technology eliminates battery back-up
and maintains thermostat settings during power failure for up to
24 hours
•Two Separate (Day & Night) time and temperature settings per
day
*individual Slide Switches set day and night heat and cool
temperatures and nighttime beginning and ending time periods
• "Cancel Night' button overrides night temperature settings
•"+" and "—" buttons set time of day
*Pressing front cover reviews thermostat settings
i
Optional Outdoor Temperature Sensor A2000 -ROS
With optidnal sensor, thermostat will give a readout of present out-
door temperature and lowest and highest outdoor temperatures of
the day and times at which they occurred. See next page.
NOTE — Specifications, Ratings and Dimensions subject to change without notice.
November 1996
Supersedes #460059
September 1993
1_21,SERIES 7 DAY THERMOSTATS
For Conventional Heating/Cooling Systems Only
(Non -Heat Pump Systems)
Model No. Description Catalog No.
L211407CS .......... 1 Heat/1Cool 7 -Day ......... 75H19
L212407CS .......... 1 Heat/2 Cool 7 -Day ......... 75H2O
A2000 -ROS ..... Outdoor Temperature Sensor .... 691-127
*Full Independent Seven-day Programming
*Automatic Or Manual Changeover
*Built-in Time Delays
• Large Easy -to -read LCD Readout
•Actual Time And Temperature in OF or °C for alternating inside
and outside temperature readout (with optional outdoor
temperature sensor)
*Two Stage Cooling Model features low or high speed cooling
operation indicator
*Check Filter Indicator flashes at preset interval
*System Selector Switch (Off -Heat -Cool -Auto)
*Fan Switch (On -Auto)
•Indicator Lights show "Amber" indicating system is operating
in manual mode or (flashing) 3 hour override, "Green" light
indicates system demand
•Solid-state Electronic Technology eliminates battery back-up
and maintains thermostat settings during powerfailure for up to
24 hours :
*Four Separate Time And Temperature Settings Per Day
*Individual Slide Switches set time begin and heat and cool
temperatures
• "+" and "—" buttons set time of day
• "Day" button sets day of week and reviews daily programs
•"Review" button displays programmed time period setpoints
• "Manual" button allows manual control of temperature
•"Clear" button erases programmed. setpoints when
re -programming
*"Enter" button enters time of day and temperature setpoints
into memory
•Monitors compressor run times and heating times in hours and
cycles
*Pressing front cover reviews thermostat settings
Optional Outdoor Temperature Sensor A2000 -ROS
With optional sensor, thermostat will give a readout of present out-
door temperature and lowest and highest outdoor temperatures of
the day and times at which they occurred See next page.
.)1996 Lennox Industries Inc. ;,'