Loading...
05-1940 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: Schenkman #2 77-777 Calle Colima La Quinta, CA 92253 Project Designer: LENCH DESIGN STUDIO, INC P.O. BOX 450 LA QUI NTA, CA 92247-0450 760/564-1866 OFVILC� CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT 0 11 BY Report Prepared By: S.L.O.- Santiago .L.O..Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247. (760) 485-8927 Job Number: 3.1-1340 Date: 8/19/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft . Job Number: 3.1-1340 User Number: 5732 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 9 13 14 17 20 23 EnergyPro 3.1 By EnergySoft Job Number: 3.1-1340 User Number: 5732 1 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Schenkm_an #2 _ 8/19/2006 Project Title Date 77-777 Calle Colima La Quinta Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,858 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 3,858 ft' Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments TVDe Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof R-19 Wall (W.19.2x6.16) Wood 0.065 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-19 Wall (W.19.2x6.16) 1/2+5/8 GYP Wood 0.060 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 44.0 0.44 0.42 None ❑ x❑ ❑ X❑ Front (North) 30.0 0.38 0.40 Bug Screen ❑ 0 ❑ X❑ Right (West) 58.5 0.38 0.40 Bug ScreenX❑ ❑ ❑ X❑ Rear (South) 48.0 0.34 0.35 Bug Screen Q ❑ ❑ X❑ Front (North) 48.0 0.34 0.35 Bug Screen Q ❑ ❑ X❑ Right (West) 24.0 0.39 0.40 Bug Screen Q ❑ ❑ x❑ Right (West) 96.0 0.34 0.35 Bug Screen x❑ ❑ ❑ X❑ Right (West) 58.0 0.36 0.37 Bug Screen X❑ ❑ ❑ Q Left (East) 9.0 0.38 0.40 Bug Screen ❑ X❑ ❑ X❑ Left (East) 10.0 0.36 0.37 Bug Screen ❑ Q ❑ x❑ Rear (South) 12.0 0.65 0.48 Bug Screen ❑ 0 ❑ 0 Rear (South) 13.5 0.36 0.37 Bug Screen ❑ 0 ❑ 0 Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347 EnergyPro 3.1 By Ener Soft User Number: 5732 Job Number: 3.1-1340 Pa e:3 of 27 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Schenkman #2 8/19/2006 Project Title Date 77-777 Calle Colima La Quinta Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,858 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 3,858 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 F� Raised Floor Component FENESTRATION Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc. Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (East) 69.0 0.47 0.60 Bug Screen ❑ x❑ ❑ x ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1:1 1:1 El F] El El El F] El El El F1 ❑ ❑ ❑ ❑ 1:1 El El 11 1:1 ❑❑ Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347 Ener Pro 3.1 By Ener Soft User Number: 5732 Job Number: 3.1-1340 Pa e:4 of 27 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Schenkman #2 8/19/2006 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnas 80% AFUE Ducts in Attic 42 Setback HVAC Zone 1 Central Furnace 80% AFUE Ducts in Attic 42 Setback HVAC Zone 2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC Zone 3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack HVAC 7nnp 1 Split Air Conditioner 120 SEER Ducts in Attic 42 Sethack HVAC 7nnp 2 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC Zone 3 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value PCO. SMITH FPS -50-224 Small Gas Standard 1 43,000 50 0.60 n/a n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: LENCH DESIGN STUDIO. INC Address: P.O. BOX 450 LA QUINTA, CA 92247-0450 Telephone: 760/564-1866 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) Name: S.L.O. Title/Firm: Santiago Lopez-Ocampo Address: P.O. Box 1018 La Quinta. CA 92247 Telephone: (760) 485-8927 (signature) (date) (signature/stamp) (date) Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:5 of 27 Certificate of Compliance: Residential (Addendum) CF -1 R Schenkman #2 8/19/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1751 sqft Exposed Slab Floor, 3.50" thick at Zone 1 The HVAC System "HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 731 sqft Covered Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 431 sqft Exposed Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 482 sqft Covered Slab Floor, 3.50" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 463 sqft Exposed Slab Floor, 3.50" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:6 of 27 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential,buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§ 150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑'§150(c): X not apply to exterior mass walls). '§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. 0 § 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no Elgreater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. A-1 §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. IAI § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. Al §150(h): Heating and/or cooling loads calculated in accordancewith ASHRAE, SMACNA or ACCA. Al §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:7 of 27 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. F IA -11 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) E] §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. n§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:8 of 27 Computer Method Summary (Part 1 of 3) C -2R Schenkman#2 M-9120-0-6 Project Title Date 7_7-777- CalleSGolima-1- (0) *ata Project Address Building Permit # SarltiP7-- mn (760) 485-8927 plan Check/Date Documen tion Author Telephone Compce 15 1 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.01 2.57 0.44 Space Cooling 35.01 34.70 0.31 Domestic Hot Water 7.39 6.50 0.88 Totals 45.40 43.77 1.63 Percent 3.6% Total Conditioned Floor Area: 3,858 ft2 Floor Construction Type: ❑ Raised Floor X❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 13.5% Number of Dwelling Units: 1.00 Total Conditioned Volume: 38,580 ft' Number of Stories: 1 Total Conditioned Slab Area: 3,858 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area JWACZone 11 7575 17 510 -OAb_ Conditioned_ -Setback_ _2 -_nLa .HYAC2one? 1,162 --tU20 000_ Conditioned_ _Setback_ 2 _nLa HV r. lone --'A 945 _9.450 _0.24_-ondifioned_ Setback_ _.n/a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Roof_ 1235 _0_024 0-0 Wall- 1.5 0 0.6.5_ 0_ 9.0 Wall ____-_30 0_0.6.5 _9.0 9.0_ Mall_ 82 X065 _() �0 .DooL ---A8 Q,38Z -0. 90. Wall_ 45_ 0.060_ _0. 90_ Wall_ -16 0-060 90 90L Wall_ -183 -0-060- 20 ----(i Wall 127 --D-06.5- 18.0 go Wall- 99 _0_0.6.5 _2.70 ---W- -Wall --W_Wall_ 5.5 -U65- 1$0 90 W all_ 81 --0-065- -27_0 ---%0 Wall- 55. _0.06.5 _0 _90 Wall- 68- 0,065 _270 90_ Wall_ 27 _0_0.6.5_ 180 9.0_ Wal{_ -----6.0_ 0.066 _27-0 _130_ Wall_ 27 _0.0.65 _0 90_ Wall_ x.92 SOBS_ _270. 90_ Roof- 1..146 --0,024 0 -0 Wall- ---29$ 0,060_ - 0 -00 Rotor 24 _0387 -0 90 Wall 519_ _0..0.65 _90_ _90_ Wall_ 444 -0_Q65 18.0 9.0_ Wall_ 114_ -0-0-65- -270. 90_ Roos_ X8.3_ -0_024 45_ _0_ Wall- -136 -0-00- 0 90_ Wall_ ----t6 0 06D _270 90 Wall- X93 --0-06-0- 0 90. Wall- x.81 0-065 _9Q 90 Solar Gains Y / N Form 3 Reference R38-Raof (R.3.8.2x4.241 R19_Wall (W -1 9 2x6 -M R19 WaIL(W 192x616.) R19 Wall (W.19 2x616) solid WQod_Door R-19 WaIL(W_192x6 16) 1/2+5L8 GY2 R19WalL(W"19 2x6.16) 1/2+5/8--GYP- R1.910La1L" 2x616. -112+5L8 GYP- R].9_1oLa -W 19-W16) R-119Wall (W192xfi 16) JRA- 9- Lall_(. .19.2x6.16) R19Wall (W.192x616) R-19 Wall (W.19.24.16) R1_9111 ALkW_192x616 ) R191LWI L(1L1C_19..2x616 ) RS.9WalL(_-W-16 2x616) R19Wall_(_W_.192x6 ]6.) R19-WalL(W19-a616.) R38_RDDL B_3 - 4,24) R19�6LalL(�L192616)119+5L8SYP SolidWoocf Door R19Wal ()111_1.9 2x616) R1g-mll (W-19 ?YA 16) R19-LalL(-11/ 192x6.16) R3.8Boof_(R-38.2x4.24) R19WalL(W-t9.2x616)-112±5L8_GYP- R191M1L(_1WLt92x616)-12±518 GYP- R19_WaII (W 19..2x6.16)1 /2+5L8 -GYP - Location / Comments Zone 1 Zone1 Zone- - Zone 1 Zone -1 Zone -1 zone Zone - Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone -3 .Zone_3 Zone_3 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:9 of 27 1 Computer Method Summary (Part 2 of 3) C -2R Schenkman #2 8/19/2006 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments .L Skylight Front_(NodW -8_0_ 0.940- -0 42 _ 0 0. Andersen-400_S.edes_SKYLLGHT _Zone 1 2 dight Front North. 4.0 0.440 0.42 0 0 Andersen 400 Series SKYLIGHT Zone 1 3 Skylight Front North 4.0 0.440 0.42 0 0 Andersen 400 Series SKYLIGHT Zone 1 4 Window Front (North) 30.0 0.380 0.40 0 90 Milgard W. Classic Vinyl Low E Zone 1 5 Window Right est 22.5 0.380 0.40 270 90 Milgard W. Classic Vinyl Low E Zone 1 6 Window Rear South 48.0 0.340 0.35 180 90 Milgard W. Classic Vinyl Low E Zone 1 L Window Right (West).. 36.0 0.380 0.40 270 90 Milgard W. Classic Vinyl Low E Zone 1 8 Window Front North 48.0 0.340 0.35 0 90 Milgard W. Classic Vinyl Low E Zone 1 6 Windo Right (West)_ 24.0 0.390 0.40 270 90 MiI and W. Classic Vinyl Low E Zone 1 10 Window Right (West) 48.0 0.340 0.35 270 90 Milgard W. Classic Vinyl Low E Zone 1 11 Window Right (West) 40.0 0.360 0.37 270 90 Milgard W. Classic Vinyl Low E Zone 1 12 Skylight FrontNorth . 8.0 0.440 0.42 0 0 Andersen 400 Series SKYLIGHT Zone 2 13 SkyJig.ht_E wt (North) -8-0- 0.440 0.42 0 0 Andem n90O-Se es-SKYLLGH1 2 -one -2 14 Window Left (East) 9.0 0.380 0.40 90 90 Milgard W. Classic Vinyl Low E Zone 2 15 Window Left (East) 10.0 0.360 0.37 90 90 Milgard W. Classic Vinyl Low E Zone 2 16 Window Rear (South) 3.0 0.650 0.48 180 90 WECK, GLASS BLOCK 8x8x4 Zone 2 17 Window Rear South 4.5 0.650 0.48 180 90 WECK, GLASS BLOCK 8x8x4 Zone 2 18 Window Rear (South) 4.5 0.650 0.48 180 90 WECK, GLASS BLOCK 8x8x4 Zone 2 10 Window Rear (South) 4.5 0.360 0.37 180 90 Milgard W, Classic Vinyl Low E Zone 2 20 Window Rear (South) 4.5 0.360 0.37 180 90 Milgard W. Classic Vinyl Low E Zone 2 21 Window Rear (South) 4.5 0.360 0.37 180 90 Milgard W. Classic VinylLow E_ Zone 2 .22 Window Right (West) 18.0 0.360 0.37 270 90 Milgard W. Classic Vinyl Low E Zone 2 23 Window Right (West) 48.0 0.340 0.35 270 90 Milgard W. Classic Vinyl Low E Zone 2 24 Skylight Front (Northeast) 4.0 0.440 0.42 45 0 Andersen 400 Series SKYLIGHT Zone 3 25 dight Front (Northeast) 4.0 0.440 0.42 45 0 Andersen 400 Series SKYLIGHT Zone 3 26 Skylight Front (Northeast) 4.0 0.440 0.42 45 0 Andersen 400 Series SKYLIGHT Zone 3 27 Window Left (East) 30.0 0.470 0.60 90 90 Elite Windows & Doors Low -E Zone 3 28 Window Left (East) 9.0 0.470 0.60 90 90 Elite Windows & Doors Low -E Zone 3 29 Window Left East 30.0 0.470 0.60 90 90 Elite Windows & Doors Low -E Zone 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 4 Bug Screen 0.76 5 Bug Screen 0.76 4.5 5.0 12.3 0.1 0.0 0.0 6 Bug Screen 0.76 8.0 6.0 24.5 0. 2 4 2.0 7 Bug Screen 0.76 6.0 6.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 6.0 28.7 0.1 2.0 2.0 9 Bug Screen 0.76 6.0 4.0 12.3 0.1 0.0 0.0 10 Bug Screen 0.76 8.0 6.0 12.3 0.1 0.0 0.0 Ti- Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 12 None 1.00 13 None 1.00 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 6.0 3.0 15.2 0.1 2.0 2.0 23 Screen 0.76 8.0 6.0 25.0 0.1 2.0 2.0 24 None 1.00 25 None _ 1.00 26 None 1.00 27 Bug Screen 0.76 28 Bu! 0.76 0.76 29 Bug Screen 0.76 Run Initiation Time: 08/19/0613:45:47 Run Code: 1156020347 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 10 of 27 Computer Method Summary Minimum Distribution Type (Part 3 of 3) C -2R Schenkman #2 Type (furnace, heat Efficiency and Location Duct 8/19/2006 Project Title pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Date THERMAL MASS FOR HIGH MASS DESIGN 80% AFUE Ducts in Attic 4.2 Setback Area Thick. Heat Ducts in Attic 4.2 Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Con rete. Heavyweight 1.751 _3_5.0 _28. J198. n/a 0 ZonelLSlab-an Glade Concrete, Heavyweight 731 3_50 28 0_98 n/a Ratedl Tank 2 Zone 2 / Slab on Grade Concrete. Heavvweiaht 431 3.50 28 -0-W n/a R -Value _ 0 Z9ne 2 / SlaIZon Grade Concrete, Heavyweight 482 3_50 28 0_98 n/a Small Gas 2 Zone 3 / Slab on Grade Concmte L1eavy_weig.bt 463 3.50 28 0.98 n/a 0 Zone 3 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 145 0.76 0.0 0 Zone 1 Slab eedmeter 42 _026 2Q0 Zone2 Slaeser b Penm . 0.76 0.0 0 Zone 2 -Slab Red meter OS -O-Z6 2Q 0 Zone_3 S.lab_Eerimeter 9 0.76 0,0 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC 1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC Zone 2 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC Zone 3 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC Zone 2 Split Air Conditioner 12.0 SEER Ducts in Attic . 4.2 Setback HVAC Zone 3 WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Standard 1 43,000 50 0.60_ n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS I EneravPro 3.1 By EnerovSoft User Number: 5732 Job Number: 3.1-1340 Pane: 11 of 27 1 Computer Method Summary (Addendum) C -2R Schenkman #2 8/19/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1751 sqft Exposed Slab Floor, 3.50" thick at Zone 1 The HVAC System "HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 731 sqft Covered Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 431 sqft Exposed Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 482 sqft Covered Slab Floor, 3.50" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 463 sqft Exposed Slab Floor, 3.50" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field Run Initiation Time: 08/19/06 13:45:47 Run Code: 1166020347 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 12 of 27 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Schenkman #2 1 8/19/2006 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM ASSEMBLY NAME R-19 Wall .19.2x6.16 1/2+5/8 GYP Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor Insulation, Mineral Fiber, R-19 4 TYPE Wall (check one) 5 W W LU Ceiling / Roof 1.06 H FRAMING MATERIAL Wood 8 p FRAMING % 15 %o Framing /o 0.680 1 20.92 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-19 4 Gypsum or Plaster Board 5 2.87 6 1.06 7 0.26 8 9 INSIDE SURFACE AIR FILM SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 0.060 0.060 19.002 5.940 0.450 0.450 2.87 0.37 1.06 2.08 0.26 0.54 0.6801 0.680 1 20.92 7.86 KG KT 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0478 --IX 0.85 2.601 0.26 0.68 0.06 0.35 0.02 2.87 0.37 1.06 2.08 0.26 0.54 7.61 TOTAL HC 2 3 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0478 --IX 0.85 + [ 0.1272I X L 0.15 1 1 / Rc 1 - (Fr-/. / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EneravPro 3.1 By EnergvSoft User Number: 5732 Job Number: 3.1-1340 Page:13 of 27 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Schenkman #2 8/19/2006 SYSTEM NAME FLOOR AREA HVAC Zone 1 1,751 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sgft) 37.1 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 33.4 Total Output (sgft/Ton) 359.2 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.14 Airflow (cfmrron) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26.0 of 69.6 of 69.6 of - .- QY Outsidee Airit 0 cfm Supply Fan 2000 cfm 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 813 14,661 0 568 17,953 0 733 898 0 0 0 0 0 0 0 0 0 733 898 16,1271 0 19 748 York H4DH060/PDHUCO20L60 U&H 37,541 12,421 65,000 Total Adjusted System Output 37,541 12,421 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Heating Coil at Time of H k Return Air Ducts 4 Supply Air Ducts 99.7 of ROOMS 70.0 of (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 111.0/77.6OF 74.3/62.1OF 74.3/62.2OF 56.7/55.7OF 11 Jw O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 57.1 / 55.9 of 2000 cfm 51.3% R.H. ROOMS 74.3/62.1 of 74.0 /62.0 of �% Return Air Ducts ; EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 14 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Schenkman #2 8/19/2006 SYSTEM NAME FLOOR AREA HVAC Zone 2 1,162 Number of Systems 1 Heating System Output per System 53,000 Total Output (Btuh) 53,000 Output (Btuh/sgft) 45.6 Cooling System Output per System 35,200 Total Output (Btuh) 35,200 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 30.3 Total Output (sgftrron) 396.1 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.03 Airflow (cfm/Ton) 409.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent CFM Sensible 514 9,319 0 263 11,382 0 466 569 0 0 0 0 0 0 0 0 0 466 569 10,251 0 York H4DH036S06/P3HUAO53 U&H 22,704 7,328 Total Adjusted System Output 22 704 7,328 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) 26.0 of 69.6 of 69.6 of 0 111.10F Outside Air 0 cfm 69.6 of M Supply Fan Heating Coil 1200 cfm 1% Return Air Ducts `i 53,000 53,000 Jan 12 am Supply Air Ducts 110.6 of ROOMS 70.0 of (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 11.0 / 77.6 of Outside Air 0 cfm 74.4/62.10F 74.4/62.1OF 0 74.4 / 62.2 of. 56.6 / 55.6 of Supply Fan Cooling Coil 1200 cfm K Return Air Ducts '4 Supply Air Ducts 57.0 / 55.7 of 51.0% R.H. ROOMS 74.0 / 62.0 of EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page 15 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Schenkman #2 8/19/2006 SYSTEM NAME FLOOR AREA HVAC Zone 3 945 Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Btuh/sgft) 33.9 Cooling System Output per System 23,400 Total Output (Btuh) 23,400 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 24.8 Total Output (sgft/Ton) 484.6 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 0.85 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 8,256 CFM Sensible Latent �COILHTG.PEAKI CFM Sensible 464 8,256 0 149685 8 0 413 293 0 0 0 0 0 0 0 0 0 413 293 9 081 0 6 455 York H4DH024/P4HUA08LO32 U&H 15,051 4,964 32,000 Total Adjusted System Output 15,051 4,964 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.7 of 69.7 of 107.2 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 106.9 of 800 cfm ROOMS 70.0 of 69.7 of I Return Air Ducts Temperatures at Time of Coo 11.0 / 7T6 OF 74.5 / 62.2 OF 74.5 / 62.3 OF---. 56.8 / 55.8 OF �1 Outside Air 0 cfm 74.5/62.2 OF Supply Fan Cooling Coil 800 cfm Return Air Ducts Supply Air Ducts 57.3 / 56.0 of 51.5% R.H. ROOMS 74.0 / 62.1 of i EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 16 of 27 1 ROOM LOAD SUMMARY PROJECT NAME Schenkman #2 DATE 8/19/2006 SYSTEM NAME HVAC Zone 1 FLOOR AREA 1,751 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 813 14,661 0 813 14,661 0 568 17,953 PAGE TOTAL 1 8131 14,661 0 568 17,953 TOTAL 1 813 14,661 0 568 17,953 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page 17 of 27 ROOM LOAD SUMMARY PROJECT NAME Schenkman #2 DATE 8/19/2006 SYSTEM NAME HVAC Zone 2 FLOOR AREA 1,162 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 514 9,319 0 514 9,319 0 263 11,382 PAGE TOTAL 1 514 9,319 0 263 11,382 TOTAL 1 514 9,319 0 263 11382 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 18 of 27 ROOM LOAD SUMMARY PROJECT NAME Schenkman #2 DATE 8/19/2006 SYSTEM NAME HVAC Zone 3 FLOOR AREA 945 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Zone 3 1 464 8,256 0 464 8,256 0 149 5,868 PAGE TOTAL 1 4641 8,2561 0 149 5,868 TOTAL 1 464 8,256 Oil 149 5,868 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 19 of 27 ROOM HEATING PEAK LOADS Project Title Date Schenkman #2 8/19/2006 Room Information Desi - n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 1,751 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 1735.0 X X X X X X X x X X x X x X X X X X X X X X X x X x X X X X X X X X x x X X X 0.0241 x x X X x X X X X x x X X X X X X X X X X X X X X X x X X X X X X X x X x X I X 44.0 = = = = = = = = = = = = = = = = = = = = = = = 1,836 16.0 0.4400 44.0 310 1116.7 0.0655 44.0 3,216 88.5 0.3800 44.0 1,480 48.0 0.3872 44.0 818 244.1 0.0597 44.0 641 144.0 0.3400 44.0 2,154 24.0 0.3900 44.0 412 40.0 0,360 44.0 634 perimeter = 145.0 6.452 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17 953 Infiltration: L 1.001 x 1.064 x 1 751 x 10.00 x 6] x W = 0 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,953 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:20 of 27 ROOM HEATING PEAK LOADS Project Title Date Schenkman #2 18/19/2006 Room Information Desi - n Conditions Room Name zone 2 Time of Peak Jan 12 am Floor Area 1,162 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Wood Door 1146.0 X X X X X x X x X X x X X X X X X X X X x X X x X X X X X x X x X X X X X X X 0.0241 x X X X X x X X X X X X X X x X X X X x X X X X X X X X x X X X X X X x X x X 44.0 = = = = = = = = = = = = = = = = = = = = = = 1,213 16.0 0.4400 44.0 310 298.5 0.0597 44.0 784 24.0 0.3872 44.0 409 1077.8 0.0655 44.0 3.104 9.0 0.3800 44.0 150 41.5 0.3600 44.0 657 12.0 0.6500 44.0 343 48.0 0,340 44.0 718 perimeter = 83.0 3,694 Items mown witn an astensK (1 aenote conauction tnrougn an interior surtace to anotner room. Page Total: I 11,382 Infiltration: r 1.00 1 X 1.064 X 1 162 x 10.00 x 60] X schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,382 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 21 of 27 ROOM HEATING PEAK LOADS Project Title Date Schenkman #2 8/19/2006 Room Information Design Conditions Room Name zone 3 Time of Peak Jan 12 am Floor Area 945 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 700I Conduction Area U -Value AT of Btu/hr R-38 Roof R.38.2x4.24 Andersen 400 Series SKYLIGHT - 9-WaIL(W19.24-1-61 1/2+5L8 G R-19 Wall W.19.2x6.16 lite 1L1(indows-&-Daots-L Slab -On -Grade 933.0 x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0241 X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 987 12.0 0.4400 44.0 232 342.4 0.0597 44.0 899 281.0 0.0655 44.0 809 69.0 0.4700 44.0 1.427 perimeter 34.0 44.5 1,513 items snown with an asterisk (-)� denote conauction tnrougn an interior surtace to anotner room. Page Total: 5,868 Infiltration: I1 1.001 X 1 1.0641 X 945 x 10.00 x 0.00 / 60] X 0 = QO schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 5,868 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 22 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Schenkman #2 8/19/2006 Project Title Date Room Name Zone 1 Design Indoor Dry Bulb Temperature: 740F 0 Design Outdoor Dry Bulb Temperature: 112 F Design Temperature Difference: 380F Conduction R-38 Roof R.38.2x4.24 Andersen 400 Series SKYLIGHT -19 Wall .19.2x6.16 Mil and W. Classic Vinyl Low E Solid Wood Door R-19 Wall .19.2x6.16 1/2+5/8 GYP Mil and W. Classic Vinyl Low E Mil and W. Classic Vinyl Low E . iloard_W-Classic_V_irnvLLow 1. Design Equivalent Temperature Difference (DETD) Area Items shown with an asterisk (') denote conduction through an interior surface Solar Gain Orientation 4020 Skylight (Skylight) 020-Skyligh (Skylight) 2020 Skylight (Skylight) 6050 xo (North) 5046 xo (West) 2 3080 fr.dr. (South) 6060 xo (YV/ St) 2 3080 fr.dr. (North) 4060 sh (West) 2 3080 fr.dr. West 1.735.4 X U -Value 0.0241 0.4400 0.0655 0.3800 0.3872 0.0597 0.3400 0.3900 _360D X X X X X X X DETD 1 = = = = = = =A1,860X =X = Btu/hr 55.0 2,295 38.0 268 34.6 2,529 38.0 1,278 34.6 643 34.6 504 38.0 SC 38.0 0.0 38..0 Page Total 1 10 280 to another room. J Shaded Unshaded Area SGF Area SGF SC Btu/hr 0.0 X 1 + 8.0 X 152 ) X 0.483 = 587 0.0 X 1 + 4.0 X 152 ) x 0.483 = 294 0.0 x 1 + 4.0 X 152)x 0.483 = 294 0.0 x 1 + 30.0 X 15)x 0.445 = 200 22.5 x 1 + 0.0 x 73) x 0.445 = 150 48.0 x 1 + 0.0 X 32) x 0.390 = 281 9.0 x 15 + 27.0 X 73) X 0.445 = 938 0.0 X --1;1 1 + 48.0 X 15) X 0.390 = 281 24.0 x + 0.0 X 73) X 0.445 __ 160 48.0 x 15 + F 0.0 x 73 ) x 0.390 = 281 Sched. Page Total 3 asa Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,751 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Occupants 1.00 x 1,751 X 0 Btuh/occ. / 291 sgft/occ. = 0 Receptacle 1.00 x 1,751 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 X 1,751 X 0.000 Watts/sqft x 3-413 Btuh/Vllatt = 0 Infiltration: = oo x t.o x t,�5� x too x o o9 / 60] -8 = chedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14661 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 751 X 0 Btuh/OCC. / 291 sgft/occ.= 0 Receptacle 1.00 x 1 751 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Process r 1.00 x 1 751 x 0.000 Watts/sgft x 3.41 Btuh/VVatt = 0 Infiltration: I 1.00 x 4.771 X 1 751 x 10.00 x o.00 / 60] 0.00000 = �0 chedule Air Latent Area Ceiling Height ACH Z -\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 23 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Schenkman #2 8/19/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD' Zone 1 740F 112°F 380E Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total L_ 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr 8050 fix (West) ( 12.0 X 1 + 28.0 X 73) X 0.412 = 916 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( X + X )X Sched. Page Total 916 Internal Gain Frac. Area Heat Gain Btu/hr Licihts 1.00 x 1,751 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Occupants 1.00 X 1,751 X 0 Btuh/OCC. / 291 sgft/occ. = 0 Receptacle 1.00 x 1,751 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process rX1.00 �x 1,751 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 00 Infiltration: I 1.0o X=4 x 1 Z51 x 0 o x O o / 60] m = =o -- chedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,6611 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 X 1 751 x 0 Btuh/OCC. / 291 sgft/occ. = 0 Receptacle 1.00 x 1 751 x 0.000 Watts/sgft X 3.413 Btuh/Watt = 0 Process 1.00 x 1 751 x 0.000 Watts/sgft X 1 3.4d, Btuh/Watt = o Infiltration: 1.00 X 4 771 X 1 75 X 10.00 X 0.00 / 60] 0.00000 = chedule Air Latent Area Ceiling Height ACH Z\ -W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 24 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Schenkman #2 8/19/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof R.38.2x4.24 ndersen 400 Series SKYLIGHT 19 Wall M.19.2x6.16 1/2+5/8 GYP olid Wood Door R-19 Wall (W.19.24.16 Milgard W. Classic Vin I Low E Mil and W. Classic Vinyl Low E NECK, GLASS BLOCK 8x8x4 ilaarrLW__Classic-/it mLLa Area U -Value X .024, Zone 2 740F 1120F 380F X X X X X X X X X DETD 1 = = = = = = = = = Btu/hr 55.0 1,516 38.0 268 34.6 617 34.6 322 34.6 2,441 38.0 130 38.0 568 38.0 296 38_0 620 1. Design Equivalent Temperature Difference (DETD) Page Total 6.777 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 4020 Sk li ht (Skylight) _4020 -Skylight (Skylight) 3030 xo (East) 5020 fix East 3010 glass Block (South) 3016 lass Block (South) 3016 glass Block (South) 3016 fix (South) 3016 fix (South) 3016 fix South ( 0.0 X X X x X X x1 x X X 1 + + + + + + + + + + 8.0 x X X x X X X X X X 152 ) X X X x x X X x x 0.483 = = = = = = = = = = 587 ( 0.0 1 8.0 152) 0.483 587 ( 0.0 1 9.0 73) 0.445 293 ( 0.0 1 110.0 73) 0.412 301 ( 0.0 1 3.0 32) 0.534 51 ( 0.0 1 4.5 32) 0.534 77 ( 0.0 4.5 32) 0.534 77 ( 0.0 1 4.5 32)x 0.412 59 ( 0.0 1 4.5 32) 0.412 59 ( 0.0 1 4.5 32) 0.412 59 Sched. Page Total 2150 Internal Gain Frac. Area Heat Gain Btu/hr Li tits 1.00 x 1,162 X 0.000 Watts/sqft X 3.413 Btuh[Watt = 0 Occupants 1.00 X 1,162 x 0 Btuh/OCC. / 193 sgft/occ. = 0 Receptacle 1.00 x 1,162 x 0.000 Watts/sgft X 3.413 Btuh/Waft = 0 Process I�1 1.00 X 1,162 X 0.000 Wattts/sq�ft x 3.41 B�tuhfWatt = 00 Infiltration: �� 0011 x ( t,o6 x ,162 x �1-o_09J x L_ -o / 60] L 38 = B OJ Schedule Air Sensible Area Ceiling Height ACH L\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,3191 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu antsL=1100 x 1 162 x 0 Btuh/OCC. / 193 sgft/occ. = 0 Receptacle x 1 162 x 0.000 Watts/sqft X 3.41 Btuh/Waft = o Process X 1 162 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Infiltration: 1.00 X 4 771 x 1 162 x 10.00 x 0.00 / 60] 1 0.00000 = 0 -Schedule Air Latent Area Ceiling Height ACH &W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 25 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Schenkman #2 8/19/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value DETD' Zone 2 740F 112°F 380F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 3060 fix (West) ( 18.0 X 1 + 0.0 X 73) X 0.412 = 111 _3.0.8.0Jr.d (West) ( 48.0 X 1 + 0.0 X 73) x 0.390 = 281 ( x + X )X ( x + X )X ( X + X )X = ( X + X )X ( x + X )X = ( X + X )X ( X + X )X Sched. Page Total 392 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 1,162 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0 Occupants 1.00 X 1,162 X 0 Btuh/OCC. / 193 sgft/occ. = 0 Receptacle 1.00 x 1,162 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 X X�1,1662�2 x�� 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: 00 x 1.064 x �_,,m x L_�0_QOJ x QQ1 / 60] 38 = `schedule Air Sensible Area Ceiling Height ACH L\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM g 31g Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants x 1 162 x 0 Btuh/occ. / 193 sgft/occ. = 0 Receptacle x 1 162 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process r 11100 x 1 162 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: I1 1.00 X 4,7711 X 1 162 X 10.00 x 0.00 /601 1 0.00000 = �0 `Schedule Air Latent Area Ceiling Height ACH LWy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 26 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Schenkman #2 8/19/2006 Project Title Date Room Name Zone 3 Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 112 0F Design Temperature Difference: 380 F Conduction Area U -Value X 1 0.02411 X X X X X DETD 1 = = = = = Btu/hr 55.0 1,234 38.0 201 34.6 707 34.6 636 38.0 1,232 1. Design Equivalent Temperature Difference (DETD) Page Total 4 011 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 2020 Skylight (Skylight 2-020-Skylight (Skylight)_ 2020 Skylight (Skylight) 5060 xo 3030 xo (East) (East) 5060 xo (East) 294 ( 0.0 1 4.0 152) 0.483 294 ( 0.0 0.0 X X X x X x x X X 1 + + + + + + + + 4.0 X x x x x x x X X 152) X x X x x x x )x ) X 0.483 = = = = = = = 294 ( 0.0 1 4.0 152) 0.483 294 ( 0.0 141+ 4.0 152) 0.483 294 ( 0.0 1 30.0 73) 0.668 1,463 ( 0.0 1 9.0 73) 0.668 439 ( 0.0 15 30.0 73) 0.668 1,463 ( ( -) ( -- Sched. Page Total alas Internal Gain Frac. Area Heat Gain Btu/hr Li ht5 1.00 x 945 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Occu ants 1.00 x 945 x 0 Btuh/OCC. / 236 sgft/OCc. = 0 Receptacle 1.00 x 945 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 945 x X0.000 Watts/�sgftfx 3.41 Btuh/Watt = 00 Infiltration: C o0 x 1.064 x 99.5 x [= oo I 0.001 x / 60]3.8 = E=o Schedule Air Sensible Area Ceiling Height ACH Z -\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,25d Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants d -111--- x say x 0 Btuh/occ. / 236 sgft/occ. = 0 Receptacle x 945 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process x 945 x 0.000 Watts/sqft X 1 3.411 Btuh/Watt = o Infiltration: 1.00 X 4 7t x 94 X Heigh X 60] 0.00000 = Schedule Air Latent Area Ceiling Height ACH 4-\yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 27 of 27