05-1940 (SFD) Title 24TITLE 24 REPORT
Title 24 Report for:
Schenkman #2
77-777 Calle Colima
La Quinta, CA 92253
Project Designer:
LENCH DESIGN STUDIO, INC
P.O. BOX 450
LA QUI NTA, CA 92247-0450
760/564-1866
OFVILC�
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DAT 0 11 BY
Report Prepared By:
S.L.O.-
Santiago
.L.O..Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, CA 92247.
(760) 485-8927
Job Number:
3.1-1340
Date:
8/19/2006
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft . Job Number: 3.1-1340 User Number: 5732
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary
Form ENV -3 Proposed Construction Assembly
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
7
9
13
14
17
20
23
EnergyPro 3.1 By EnergySoft Job Number: 3.1-1340 User Number: 5732 1
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Schenkm_an #2 _ 8/19/2006
Project Title Date
77-777 Calle Colima La Quinta
Project Address Building Permit #
Santiago Lopez-Ocampo (760) 485-8927 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,858 ft2 Average Ceiling Height: 10.0 ft
Total Conditioned Slab Area: 3,858 ft'
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
Const.
Component Frame Assembly Location/Comments
TVDe Type U -Value (attic, garage, typical, etc.)
R-38 Roof (R.38.2x4.24)
Wood
0.024
Exterior Roof
R-19 Wall (W.19.2x6.16)
Wood
0.065
Exterior Wall
Solid Wood Door
None
0.387
Exterior Door
R-19 Wall (W.19.2x6.16) 1/2+5/8 GYP
Wood
0.060
Exterior Wall
Slab On Grade
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
FENESTRATION
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes
/ No
Skylight
44.0
0.44
0.42
None
❑
x❑
❑
X❑
Front
(North)
30.0
0.38
0.40
Bug Screen
❑
0
❑
X❑
Right
(West)
58.5
0.38
0.40
Bug ScreenX❑
❑
❑
X❑
Rear
(South)
48.0
0.34
0.35
Bug Screen
Q
❑
❑
X❑
Front
(North)
48.0
0.34
0.35
Bug Screen
Q
❑
❑
X❑
Right
(West)
24.0
0.39
0.40
Bug Screen
Q
❑
❑
x❑
Right
(West)
96.0
0.34
0.35
Bug Screen
x❑
❑
❑
X❑
Right
(West)
58.0
0.36
0.37
Bug Screen
X❑
❑
❑
Q
Left
(East)
9.0
0.38
0.40
Bug Screen
❑
X❑
❑
X❑
Left
(East)
10.0
0.36
0.37
Bug Screen
❑
Q
❑
x❑
Rear
(South)
12.0
0.65
0.48
Bug Screen
❑
0
❑
0
Rear
(South)
13.5
0.36
0.37
Bug Screen
❑
0
❑
0
Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347
EnergyPro 3.1 By Ener Soft
User Number: 5732
Job Number: 3.1-1340
Pa e:3 of 27
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Schenkman #2 8/19/2006
Project Title Date
77-777 Calle Colima La Quinta
Project Address Building Permit #
Santiago Lopez-Ocampo (760) 485-8927 Plan Check I Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,858 ft2 Average Ceiling Height: 10.0 ft
Total Conditioned Slab Area: 3,858 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 F� Raised Floor
Component
FENESTRATION
Const.
Frame Assembly Location/Comments
Type U -Value (attic, garage, typical, etc.
Shading Devices
Type Orientation Area Fenestration Exterior
Overhang Side Fins
SF U -Factor SHGC Shading
Yes / No
Yes / No
Left (East) 69.0 0.47 0.60 Bug Screen
❑ x❑
❑ x
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
1:1 1:1
El F]
El El
El F]
El El
El F1
❑ ❑
❑ ❑
1:1 El
El
11 1:1
❑❑
Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347
Ener Pro 3.1 By Ener Soft User Number: 5732 Job Number: 3.1-1340
Pa e:4 of 27
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Schenkman #2 8/19/2006
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
Central Furnas 80% AFUE Ducts in Attic 42 Setback HVAC Zone 1
Central Furnace 80% AFUE Ducts in Attic 42 Setback HVAC Zone 2
Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC Zone 3
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack HVAC 7nnp 1
Split Air Conditioner 120 SEER Ducts in Attic 42 Sethack HVAC 7nnp 2
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC Zone 3
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Facts 1
External
Water Heater Water Heater Distribution
# in Input
Cap.
or Recovery Standby
Tank Insul.
System Name Type Type
Syst. Btu/hr
(gal)
Efficiency Loss (%)
R -Value
PCO. SMITH FPS -50-224 Small Gas Standard
1 43,000
50
0.60 n/a
n/a
For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: LENCH DESIGN STUDIO. INC
Address: P.O. BOX 450
LA QUINTA, CA 92247-0450
Telephone: 760/564-1866
Lic. #:
(signature)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(date)
Name:
S.L.O.
Title/Firm:
Santiago Lopez-Ocampo
Address:
P.O. Box 1018
La Quinta. CA 92247
Telephone: (760) 485-8927
(signature) (date)
(signature/stamp) (date)
Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:5 of 27
Certificate of Compliance: Residential (Addendum) CF -1 R
Schenkman #2 8/19/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The HVAC System "HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1751 sqft Exposed Slab Floor, 3.50" thick at Zone 1
The HVAC System "HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 731 sqft Covered Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 431 sqft Exposed Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 482 sqft Covered Slab Floor, 3.50" thick at Zone 3
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 463 sqft Exposed Slab Floor, 3.50" thick at Zone 3
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field
Run Initiation Time: 08/19/06 13:45:47 Run Code: 1156020347
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:6 of 27
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential,buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
'§ 150(a): Minimum R-19 ceiling insulation.
§ 150(b): Loose fill insulation manufacturer's labeled R -Value.
Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
❑'§150(c):
X not apply to exterior mass walls).
'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
0
§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
Elgreater
than 2.0 perm/inch.
❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
A-1 §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
IAI § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
Al §150(h): Heating and/or cooling loads calculated in accordancewith ASHRAE, SMACNA or ACCA.
Al §150(i): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:7 of 27
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
X❑ § 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
F IA -11 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
E] §118 (f): Cool Roof material meet specified criteria
Lighting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
n§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3,1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:8 of 27
Computer Method Summary
(Part 1 of 3) C -2R
Schenkman#2
M-9120-0-6
Project Title
Date
7_7-777- CalleSGolima-1- (0) *ata
Project Address
Building Permit #
SarltiP7-- mn
(760) 485-8927
plan Check/Date
Documen tion Author
Telephone
Compce
15
1 Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 3.01
2.57
0.44
Space Cooling 35.01
34.70
0.31
Domestic Hot Water 7.39
6.50
0.88
Totals 45.40
43.77
1.63
Percent
3.6%
Total Conditioned Floor Area: 3,858 ft2 Floor Construction Type: ❑ Raised Floor X❑ Slab Floor
Building Type: Single Fam Detached
Building Front Orientation: (North) 0 deg Total Fenestration Area: 13.5%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 38,580 ft'
Number of Stories: 1 Total Conditioned Slab Area: 3,858 ft 2
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
JWACZone 11 7575 17 510 -OAb_ Conditioned_ -Setback_ _2 -_nLa
.HYAC2one? 1,162 --tU20 000_ Conditioned_ _Setback_ 2 _nLa
HV r. lone --'A 945 _9.450 _0.24_-ondifioned_ Setback_ _.n/a
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
Roof_ 1235 _0_024 0-0
Wall- 1.5 0 0.6.5_ 0_ 9.0
Wall ____-_30 0_0.6.5 _9.0 9.0_
Mall_ 82 X065 _() �0
.DooL ---A8 Q,38Z -0. 90.
Wall_ 45_ 0.060_ _0. 90_
Wall_ -16 0-060 90 90L
Wall_ -183 -0-060- 20 ----(i
Wall 127 --D-06.5- 18.0 go
Wall- 99 _0_0.6.5 _2.70 ---W-
-Wall
--W_Wall_ 5.5 -U65- 1$0 90
W all_ 81 --0-065- -27_0 ---%0
Wall- 55. _0.06.5 _0 _90
Wall- 68- 0,065 _270 90_
Wall_ 27 _0_0.6.5_ 180 9.0_
Wal{_ -----6.0_ 0.066 _27-0 _130_
Wall_ 27 _0.0.65 _0 90_
Wall_ x.92 SOBS_ _270. 90_
Roof- 1..146 --0,024 0 -0
Wall- ---29$ 0,060_ - 0 -00
Rotor 24 _0387 -0 90
Wall 519_ _0..0.65 _90_ _90_
Wall_ 444 -0_Q65 18.0 9.0_
Wall_ 114_ -0-0-65- -270. 90_
Roos_ X8.3_ -0_024 45_ _0_
Wall- -136 -0-00- 0 90_
Wall_ ----t6 0 06D _270 90
Wall- X93 --0-06-0- 0 90.
Wall- x.81 0-065 _9Q 90
Solar
Gains
Y / N Form 3 Reference
R38-Raof (R.3.8.2x4.241
R19_Wall (W -1 9 2x6 -M
R19 WaIL(W 192x616.)
R19 Wall (W.19 2x616)
solid WQod_Door
R-19 WaIL(W_192x6 16) 1/2+5L8 GY2
R19WalL(W"19 2x6.16) 1/2+5/8--GYP-
R1.910La1L" 2x616. -112+5L8 GYP-
R].9_1oLa -W 19-W16)
R-119Wall (W192xfi 16)
JRA- 9- Lall_(. .19.2x6.16)
R19Wall (W.192x616)
R-19 Wall (W.19.24.16)
R1_9111 ALkW_192x616 )
R191LWI L(1L1C_19..2x616 )
RS.9WalL(_-W-16 2x616)
R19Wall_(_W_.192x6 ]6.)
R19-WalL(W19-a616.)
R38_RDDL B_3 - 4,24)
R19�6LalL(�L192616)119+5L8SYP
SolidWoocf Door
R19Wal ()111_1.9 2x616)
R1g-mll (W-19 ?YA 16)
R19-LalL(-11/ 192x6.16)
R3.8Boof_(R-38.2x4.24)
R19WalL(W-t9.2x616)-112±5L8_GYP-
R191M1L(_1WLt92x616)-12±518 GYP-
R19_WaII (W 19..2x6.16)1 /2+5L8 -GYP -
Location / Comments
Zone 1
Zone1
Zone- -
Zone 1
Zone -1
Zone -1
zone
Zone -
Zone 2
Zone 2
Zone 2
Zone 2
Zone 2
Zone -3
.Zone_3
Zone_3
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:9 of 27 1
Computer Method Summary (Part 2 of 3) C -2R
Schenkman #2 8/19/2006
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
.L
Skylight Front_(NodW
-8_0_
0.940-
-0 42
_ 0
0. Andersen-400_S.edes_SKYLLGHT
_Zone 1
2
dight Front
North.
4.0
0.440
0.42
0
0 Andersen 400 Series SKYLIGHT
Zone 1
3
Skylight Front
North
4.0
0.440
0.42
0
0 Andersen 400 Series SKYLIGHT
Zone 1
4
Window Front
(North)
30.0
0.380
0.40
0
90 Milgard W. Classic Vinyl Low E
Zone 1
5
Window Right
est
22.5
0.380
0.40
270
90 Milgard W. Classic Vinyl Low E
Zone 1
6
Window Rear
South
48.0
0.340
0.35
180
90 Milgard W. Classic Vinyl Low E
Zone 1
L
Window Right
(West)..
36.0
0.380
0.40
270
90 Milgard W. Classic Vinyl Low E
Zone 1
8
Window Front
North
48.0
0.340
0.35
0
90 Milgard W. Classic Vinyl Low E
Zone 1
6
Windo Right
(West)_
24.0
0.390
0.40
270
90 MiI and W. Classic Vinyl Low E
Zone 1
10
Window Right (West)
48.0
0.340
0.35
270
90 Milgard W. Classic Vinyl Low E
Zone 1
11
Window Right
(West)
40.0
0.360
0.37
270
90 Milgard W. Classic Vinyl Low E
Zone 1
12
Skylight FrontNorth
.
8.0
0.440
0.42
0
0 Andersen 400 Series SKYLIGHT
Zone 2
13
SkyJig.ht_E wt (North)
-8-0-
0.440
0.42
0
0 Andem n90O-Se es-SKYLLGH1
2 -one -2
14
Window Left
(East)
9.0
0.380
0.40
90
90 Milgard W. Classic Vinyl Low E
Zone 2
15
Window Left
(East)
10.0
0.360
0.37
90
90 Milgard W. Classic Vinyl Low E
Zone 2
16
Window Rear
(South)
3.0
0.650
0.48
180
90 WECK, GLASS BLOCK 8x8x4
Zone 2
17
Window Rear
South
4.5
0.650
0.48
180
90 WECK, GLASS BLOCK 8x8x4
Zone 2
18
Window Rear
(South)
4.5
0.650
0.48
180
90 WECK, GLASS BLOCK 8x8x4
Zone 2
10
Window Rear
(South)
4.5
0.360
0.37
180
90 Milgard W, Classic Vinyl Low E
Zone 2
20
Window Rear
(South)
4.5
0.360
0.37
180
90 Milgard W. Classic Vinyl Low E
Zone 2
21
Window Rear
(South)
4.5
0.360
0.37
180
90 Milgard W. Classic VinylLow E_
Zone 2
.22
Window Right
(West)
18.0
0.360
0.37
270
90 Milgard W. Classic Vinyl Low E
Zone 2
23
Window Right
(West)
48.0
0.340
0.35
270
90 Milgard W. Classic Vinyl Low E
Zone 2
24
Skylight Front
(Northeast)
4.0
0.440
0.42
45
0 Andersen 400 Series SKYLIGHT
Zone 3
25
dight Front
(Northeast)
4.0
0.440
0.42
45
0 Andersen 400 Series SKYLIGHT
Zone 3
26
Skylight Front
(Northeast)
4.0
0.440
0.42
45
0 Andersen 400 Series SKYLIGHT
Zone 3
27
Window Left
(East)
30.0
0.470
0.60
90
90 Elite Windows & Doors Low -E
Zone 3
28
Window Left
(East)
9.0
0.470
0.60
90
90 Elite Windows & Doors Low -E
Zone 3
29
Window Left
East
30.0
0.470
0.60
90
90 Elite Windows & Doors Low -E
Zone 3
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. REA Dist. Len. Hgt.
Dist. Len. Hgt.
1
None
1.00
2
None
1.00
3
None
1.00
4
Bug Screen
0.76
5
Bug Screen
0.76
4.5
5.0
12.3
0.1 0.0 0.0
6
Bug Screen
0.76
8.0
6.0
24.5 0. 2 4 2.0
7
Bug Screen
0.76
6.0
6.0
2.0
0.1 2.0 2.0
8
Bug Screen
0.76
8.0
6.0
28.7
0.1 2.0 2.0
9
Bug Screen
0.76
6.0
4.0
12.3
0.1 0.0 0.0
10
Bug Screen
0.76
8.0
6.0
12.3
0.1 0.0 0.0
Ti-
Bug Screen
0.76
5.0
8.0
2.0
0.1 2.0 2.0
12
None
1.00
13
None
1.00
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
6.0
3.0
15.2
0.1 2.0 2.0
23
Screen
0.76
8.0
6.0
25.0
0.1 2.0 2.0
24
None
1.00
25
None
_
1.00
26
None
1.00
27
Bug Screen
0.76
28
Bu!
0.76
0.76
29
Bug Screen
0.76
Run Initiation Time: 08/19/0613:45:47 Run Code: 1156020347
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 10 of 27
Computer Method Summary
Minimum
Distribution Type
(Part 3 of 3) C -2R
Schenkman #2
Type (furnace, heat
Efficiency
and Location
Duct
8/19/2006
Project Title
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.)
R -Value
Type
Date
THERMAL MASS FOR HIGH MASS DESIGN
80% AFUE
Ducts in Attic
4.2
Setback
Area
Thick.
Heat
Ducts in Attic
4.2
Inside
Location
Type (sf)
(in.)
Cap.
Cond. Form 3 Reference
R -Val.
Comments
Con rete. Heavyweight 1.751
_3_5.0
_28.
J198. n/a
0
ZonelLSlab-an Glade
Concrete, Heavyweight 731
3_50
28
0_98 n/a
Ratedl Tank
2
Zone 2 / Slab on Grade
Concrete. Heavvweiaht 431
3.50
28
-0-W n/a
R -Value
_ 0
Z9ne 2 / SlaIZon Grade
Concrete, Heavyweight 482
3_50
28
0_98 n/a
Small Gas
2
Zone 3 / Slab on Grade
Concmte L1eavy_weig.bt 463
3.50
28
0.98 n/a
0
Zone 3 / Slab on Grade
PERIMETER LOSSES
F2
Insulation
Type Length
Factor
R -Val.
Depth
Location / Comments
Slab Perimeter 145
0.76
0.0
0
Zone 1
Slab eedmeter 42
_026
2Q0
Zone2
Slaeser
b Penm
. 0.76
0.0
0
Zone 2
-Slab Red meter OS
-O-Z6
2Q
0
Zone_3
S.lab_Eerimeter 9
0.76
0,0
0
Zone 3
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct
Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.)
R -Value
Type
Comments
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
HVAC 1
Central Furnace
80%AFUE
Ducts in Attic
4.2
Setback
HVAC Zone 2
Central Furnace
80%AFUE
Ducts in Attic
4.2
Setback
HVAC Zone 3
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
HVAC Zone 1
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
HVAC Zone 2
Split Air Conditioner
12.0 SEER
Ducts in Attic
. 4.2 Setback
HVAC Zone 3
WATER HEATING SYSTEMS
Ratedl Tank
Energy Factl
1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery Standby
R -Value
System Name
Type
Type
Syst. Btu/hr (gal) Efficiency Loss (%)
Ext.
A.O. SMITH FPS -50-224
Small Gas
Standard
1 43,000 50
0.60_ n/a
n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
I EneravPro 3.1 By EnerovSoft User Number: 5732 Job Number: 3.1-1340 Pane: 11 of 27 1
Computer Method Summary (Addendum) C -2R
Schenkman #2 8/19/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1751 sqft Exposed Slab Floor, 3.50" thick at Zone 1
The HVAC System "HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
731 sqft Covered Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
431 sqft Exposed Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
482 sqft Covered Slab Floor, 3.50" thick at Zone 3
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
463 sqft Exposed Slab Floor, 3.50" thick at Zone 3
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field
Run Initiation Time: 08/19/06 13:45:47 Run Code: 1166020347
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 12 of 27
PROPOSED CONSTRUCTION ASSEMBLY ENV -3
PROJECT NAME DATE
Schenkman #2 1
8/19/2006
COMPONENT DESCRIPTION
DESCRIPTION
WOOD
FRAME
R -VALUE
OUTSIDE SURFACE AIR FILM
ASSEMBLY NAME R-19 Wall .19.2x6.16 1/2+5/8 GYP
Gypsum or Plaster Board
2
Membrane, Vapor -Permeable Felt
ASSEMBLY Floor
Insulation, Mineral Fiber, R-19
4
TYPE Wall
(check one)
5
W
W
LU
Ceiling / Roof
1.06
H
FRAMING MATERIAL Wood
8
p
FRAMING % 15 %o
Framing /o
0.680
1 20.92
15% (16" o.c. Wall)
12% (24" o.c. Wall)
10% (16" o.c. Floor/Ceil.)
SKETCH OF ASSEMBLY
7% (24" o.c. Floor/Ceil.)
SUBTOTAL
R -VALUE
DESCRIPTION
WOOD
FRAME
R -VALUE
OUTSIDE SURFACE AIR FILM
1
Gypsum or Plaster Board
2
Membrane, Vapor -Permeable Felt
3
Insulation, Mineral Fiber, R-19
4
Gypsum or Plaster Board
5
2.87
6
1.06
7
0.26
8
9
INSIDE SURFACE AIR FILM
SUBTOTAL
R -VALUE
CAVITY
R -VALUE
(Rc)
WOOD
FRAME
R -VALUE
0.170
0.170
0.5621
0.562
0.060
0.060
19.002
5.940
0.450
0.450
2.87
0.37
1.06
2.08
0.26
0.54
0.6801
0.680
1 20.92
7.86
KG KT
'HEAT CAPACITY (Optional)
WALL
WEIGHT
(lbs/sf)
SPECIFIC
HEAT
(Btu/F-Ib)
HC
(A X B)
(Btu/F-sf)
[ 0.0478
--IX 0.85
2.601
0.26
0.68
0.06
0.35
0.02
2.87
0.37
1.06
2.08
0.26
0.54
7.61
TOTAL HC
2 3
'NOTE: Weight and Specific Heat values for materials
penetrated by wood framing
include the effects of the framing
members.
[ 0.0478
--IX 0.85
+
[ 0.1272I
X L 0.15 1
1 / Rc
1 - (Fr-/. / 100)
1 / Rf
Fr% / 100
ASSEMBLY U -VALUE
I EneravPro 3.1 By EnergvSoft User Number: 5732 Job Number: 3.1-1340 Page:13 of 27 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Schenkman #2 8/19/2006
SYSTEM NAME FLOOR AREA
HVAC Zone 1 1,751
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
65,000
Total Output (Btuh)
65,000
Output (Btuh/sgft)
37.1
Cooling System
Output per System
58,500
Total Output (Btuh)
58,500
Total Output (Tons)
4.9
Total Output (Btuh/sgft)
33.4
Total Output (sgft/Ton)
359.2
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.14
Airflow (cfmrron)
410.3
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
26.0 of 69.6 of 69.6 of
- .- QY Outsidee Airit
0 cfm
Supply Fan
2000 cfm
69.6 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
CFM
I Sensible
813
14,661
0
568
17,953
0
733
898
0
0
0
0
0
0
0
0
0
733
898
16,1271 0 19 748
York H4DH060/PDHUCO20L60 U&H 37,541 12,421 65,000
Total Adjusted System Output 37,541 12,421 65,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Heating Coil
at Time of H
k Return Air Ducts 4
Supply Air Ducts
99.7 of
ROOMS
70.0 of
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I
111.0/77.6OF 74.3/62.1OF 74.3/62.2OF 56.7/55.7OF
11 Jw
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 57.1 / 55.9 of
2000 cfm 51.3% R.H. ROOMS
74.3/62.1 of 74.0 /62.0 of
�% Return Air Ducts ;
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 14 of 27
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Schenkman #2 8/19/2006
SYSTEM NAME FLOOR AREA
HVAC Zone 2 1,162
Number of Systems
1
Heating System
Output per System
53,000
Total Output (Btuh)
53,000
Output (Btuh/sgft)
45.6
Cooling System
Output per System
35,200
Total Output (Btuh)
35,200
Total Output (Tons)
2.9
Total Output (Btuh/sgft)
30.3
Total Output (sgftrron)
396.1
Air System
CFM per System
1,200
Airflow (cfm)
1,200
Airflow (cfm/sgft)
1.03
Airflow (cfm/Ton)
409.1
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
ISensiblel
Latent
CFM
Sensible
514
9,319
0
263
11,382
0
466
569
0
0
0
0
0
0
0
0
0
466
569
10,251 0
York H4DH036S06/P3HUAO53 U&H 22,704 7,328
Total Adjusted System Output 22 704 7,328
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK I Aug 2 pm
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak)
26.0 of 69.6 of 69.6 of 0 111.10F
Outside Air
0 cfm
69.6 of
M
Supply Fan Heating Coil
1200 cfm
1% Return Air Ducts `i
53,000
53,000
Jan 12 am
Supply Air Ducts
110.6 of
ROOMS
70.0 of
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I
11.0 / 77.6 of
Outside Air
0 cfm
74.4/62.10F
74.4/62.1OF
0
74.4 / 62.2 of. 56.6 / 55.6 of
Supply Fan Cooling Coil
1200 cfm
K Return Air Ducts '4
Supply Air Ducts
57.0 / 55.7 of
51.0% R.H. ROOMS
74.0 / 62.0 of
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page 15 of 27
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Schenkman #2 8/19/2006
SYSTEM NAME FLOOR AREA
HVAC Zone 3 945
Number of Systems
1
Heating System
Output per System
32,000
Total Output (Btuh)
32,000
Output (Btuh/sgft)
33.9
Cooling System
Output per System
23,400
Total Output (Btuh)
23,400
Total Output (Tons)
2.0
Total Output (Btuh/sgft)
24.8
Total Output (sgft/Ton)
484.6
Air System
CFM per System
800
Airflow (cfm)
800
Airflow (cfm/sgft)
0.85
Airflow (cfm/Ton)
410.3
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
8,256
CFM
Sensible
Latent
�COILHTG.PEAKI
CFM
Sensible
464
8,256
0
149685
8
0
413
293
0
0
0
0
0
0
0
0
0
413
293
9 081 0 6 455
York H4DH024/P4HUA08LO32 U&H 15,051 4,964 32,000
Total Adjusted System Output 15,051 4,964 32,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 69.7 of 69.7 of 107.2 of
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Heating Coil 106.9 of
800 cfm ROOMS
70.0 of
69.7 of I
Return Air Ducts
Temperatures at Time of Coo
11.0 / 7T6 OF 74.5 / 62.2 OF 74.5 / 62.3 OF---. 56.8 / 55.8 OF
�1
Outside Air
0 cfm
74.5/62.2 OF
Supply Fan Cooling Coil
800 cfm
Return Air Ducts
Supply Air Ducts
57.3 / 56.0 of
51.5% R.H. ROOMS
74.0 / 62.1 of
i EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 16 of 27 1
ROOM LOAD SUMMARY
PROJECT NAME
Schenkman #2
DATE
8/19/2006
SYSTEM NAME
HVAC Zone 1
FLOOR AREA
1,751
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 1
Zone 1
1
813
14,661
0
813
14,661
0
568
17,953
PAGE TOTAL 1 8131 14,661 0 568 17,953
TOTAL 1 813 14,661 0 568 17,953
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page 17 of 27
ROOM LOAD SUMMARY
PROJECT NAME
Schenkman #2
DATE
8/19/2006
SYSTEM NAME
HVAC Zone 2
FLOOR AREA
1,162
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 2
Zone 2
1
514
9,319
0
514
9,319
0
263
11,382
PAGE TOTAL 1 514 9,319 0 263 11,382
TOTAL 1 514 9,319 0 263 11382
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 18 of 27
ROOM LOAD SUMMARY
PROJECT NAME
Schenkman #2
DATE
8/19/2006
SYSTEM NAME
HVAC Zone 3
FLOOR AREA
945
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 3
Zone 3
1
464
8,256
0
464
8,256
0
149
5,868
PAGE TOTAL 1 4641 8,2561 0 149 5,868
TOTAL 1 464 8,256 Oil 149 5,868
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 19 of 27
ROOM HEATING PEAK LOADS
Project Title Date
Schenkman #2 8/19/2006
Room Information Desi - n Conditions
Room Name zone 1 Time of Peak Jan 12 am
Floor Area 1,751 Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70°F
Conduction Area U -Value AT of Btu/hr
1735.0
X
X
X
X
X
X
X
x
X
X
x
X
x
X
X
X
X
X
X
X
X
X
X
x
X
x
X
X
X
X
X
X
X
X
x
x
X
X
X
0.0241
x
x
X
X
x
X
X
X
X
x
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
x
X
x
X
I X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1,836
16.0
0.4400
44.0
310
1116.7
0.0655
44.0
3,216
88.5
0.3800
44.0
1,480
48.0
0.3872
44.0
818
244.1
0.0597
44.0
641
144.0
0.3400
44.0
2,154
24.0
0.3900
44.0
412
40.0
0,360
44.0
634
perimeter = 145.0
6.452
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17 953
Infiltration: L 1.001 x 1.064 x 1 751 x 10.00 x 6] x W = 0
Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 17,953
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page:20 of 27
ROOM HEATING PEAK LOADS
Project Title Date
Schenkman #2 18/19/2006
Room Information Desi - n Conditions
Room Name zone 2 Time of Peak Jan 12 am
Floor Area 1,162 Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
Wood Door
1146.0
X
X
X
X
X
x
X
x
X
X
x
X
X
X
X
X
X
X
X
X
x
X
X
x
X
X
X
X
X
x
X
x
X
X
X
X
X
X
X
0.0241
x
X
X
X
X
x
X
X
X
X
X
X
X
X
x
X
X
X
X
x
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
x
X
x
X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1,213
16.0
0.4400
44.0
310
298.5
0.0597
44.0
784
24.0
0.3872
44.0
409
1077.8
0.0655
44.0
3.104
9.0
0.3800
44.0
150
41.5
0.3600
44.0
657
12.0
0.6500
44.0
343
48.0
0,340
44.0
718
perimeter = 83.0
3,694
Items mown witn an astensK (1 aenote conauction tnrougn an interior surtace to anotner room. Page Total: I 11,382
Infiltration: r 1.00 1 X 1.064 X 1 162 x 10.00 x 60] X
schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 11,382
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 21 of 27
ROOM HEATING PEAK LOADS
Project Title Date
Schenkman #2 8/19/2006
Room Information Design Conditions
Room Name zone 3 Time of Peak Jan 12 am
Floor Area 945 Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 700I
Conduction Area U -Value AT of Btu/hr
R-38 Roof R.38.2x4.24
Andersen 400 Series SKYLIGHT
- 9-WaIL(W19.24-1-61 1/2+5L8 G
R-19 Wall W.19.2x6.16
lite 1L1(indows-&-Daots-L
Slab -On -Grade
933.0
x
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0241
X
X
X
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
987
12.0
0.4400
44.0
232
342.4
0.0597
44.0
899
281.0
0.0655
44.0
809
69.0
0.4700
44.0
1.427
perimeter 34.0
44.5
1,513
items snown with an asterisk (-)� denote conauction tnrougn an interior surtace to anotner room. Page Total: 5,868
Infiltration: I1 1.001 X 1 1.0641 X 945 x 10.00 x 0.00 / 60] X 0 = QO
schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 5,868
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 22 of 27
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Schenkman #2 8/19/2006
Project Title Date
Room Name Zone 1
Design Indoor Dry Bulb Temperature: 740F
0
Design Outdoor Dry Bulb Temperature: 112 F
Design Temperature Difference: 380F
Conduction
R-38 Roof R.38.2x4.24
Andersen 400 Series SKYLIGHT
-19 Wall .19.2x6.16
Mil and W. Classic Vinyl Low E
Solid Wood Door
R-19 Wall .19.2x6.16 1/2+5/8 GYP
Mil and W. Classic Vinyl Low E
Mil and W. Classic Vinyl Low E
. iloard_W-Classic_V_irnvLLow
1. Design Equivalent Temperature Difference (DETD)
Area
Items shown with an asterisk (') denote conduction through an interior surface
Solar Gain Orientation
4020 Skylight
(Skylight)
020-Skyligh
(Skylight)
2020 Skylight
(Skylight)
6050 xo
(North)
5046 xo
(West)
2 3080 fr.dr.
(South)
6060 xo
(YV/ St)
2 3080 fr.dr.
(North)
4060 sh
(West)
2 3080 fr.dr.
West
1.735.4
X
U -Value
0.0241
0.4400
0.0655
0.3800
0.3872
0.0597
0.3400
0.3900
_360D
X
X
X
X
X
X
X
DETD 1
=
=
=
=
=
=
=A1,860X
=X
=
Btu/hr
55.0
2,295
38.0
268
34.6
2,529
38.0
1,278
34.6
643
34.6
504
38.0
SC
38.0
0.0
38..0
Page Total 1 10 280
to another room.
J
Shaded
Unshaded
Area SGF
Area
SGF
SC
Btu/hr
0.0
X
1
+
8.0
X
152
) X
0.483
=
587
0.0
X
1
+
4.0
X
152
) x
0.483
=
294
0.0
x
1
+
4.0
X
152)x
0.483
=
294
0.0
x
1
+
30.0
X
15)x
0.445
=
200
22.5
x
1
+
0.0
x
73)
x
0.445
=
150
48.0
x
1
+
0.0
X
32)
x
0.390
=
281
9.0
x
15
+
27.0
X
73)
X
0.445
=
938
0.0
X
--1;1
1
+
48.0
X
15)
X
0.390
=
281
24.0
x
+
0.0
X
73)
X
0.445
__
160
48.0
x
15
+
F 0.0
x
73
) x
0.390
=
281
Sched.
Page Total 3 asa
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,751 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Occupants 1.00 x 1,751 X 0 Btuh/occ. / 291 sgft/occ. = 0
Receptacle 1.00 x 1,751 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Process 1.00 X 1,751 X 0.000 Watts/sqft x 3-413 Btuh/Vllatt = 0
Infiltration: = oo x t.o x t,�5� x too x o o9 / 60] -8 =
chedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14661
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1 751 X 0 Btuh/OCC. / 291 sgft/occ.= 0
Receptacle 1.00 x 1 751 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0
Process r 1.00 x 1 751 x 0.000 Watts/sgft x 3.41 Btuh/VVatt = 0
Infiltration: I 1.00 x 4.771 X 1 751 x 10.00 x o.00 / 60] 0.00000 = �0
chedule Air Latent Area Ceiling Height ACH Z -\W
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 23 of 27
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Schenkman #2 8/19/2006
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area U -Value
X
DETD'
Zone 1
740F
112°F
380E
Btu/hr
1. Design Equivalent Temperature Difference (DETD) Page Total L_ 1
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF Sc Btu/hr
8050 fix (West) ( 12.0 X 1 + 28.0 X 73) X 0.412 = 916
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( X + X )X
Sched. Page Total 916
Internal Gain Frac. Area Heat Gain Btu/hr
Licihts 1.00 x 1,751 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Occupants 1.00 X 1,751 X 0 Btuh/OCC. / 291 sgft/occ. = 0
Receptacle 1.00 x 1,751 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Process rX1.00 �x 1,751 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 00
Infiltration: I 1.0o X=4 x 1 Z51 x 0 o x O o / 60] m = =o
-- chedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,6611
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occu ants 1.00 X 1 751 x 0 Btuh/OCC. / 291 sgft/occ. = 0
Receptacle 1.00 x 1 751 x 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Process 1.00 x 1 751 x 0.000 Watts/sgft X 1 3.4d, Btuh/Watt = o
Infiltration: 1.00 X 4 771 X 1 75 X 10.00 X 0.00 / 60] 0.00000 =
chedule Air Latent Area Ceiling Height ACH Z\ -W
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 24 of 27
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Schenkman #2 8/19/2006
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
R-38 Roof R.38.2x4.24
ndersen 400 Series SKYLIGHT
19 Wall M.19.2x6.16 1/2+5/8 GYP
olid Wood Door
R-19 Wall (W.19.24.16
Milgard W. Classic Vin I Low E
Mil and W. Classic Vinyl Low E
NECK, GLASS BLOCK 8x8x4
ilaarrLW__Classic-/it mLLa
Area U -Value
X
.024,
Zone 2
740F
1120F
380F
X
X
X
X
X
X
X
X
X
DETD 1
=
=
=
=
=
=
=
=
=
Btu/hr
55.0
1,516
38.0
268
34.6
617
34.6
322
34.6
2,441
38.0
130
38.0
568
38.0
296
38_0
620
1. Design Equivalent Temperature Difference (DETD) Page Total 6.777
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
4020 Sk li ht
(Skylight)
_4020 -Skylight
(Skylight)
3030 xo
(East)
5020 fix
East
3010 glass Block
(South)
3016 lass Block
(South)
3016 glass Block
(South)
3016 fix
(South)
3016 fix
(South)
3016 fix
South
( 0.0
X
X
X
x
X
X
x1
x
X
X
1
+
+
+
+
+
+
+
+
+
+
8.0
x
X
X
x
X
X
X
X
X
X
152
) X
X
X
x
x
X
X
x
x
0.483
=
=
=
=
=
=
=
=
=
=
587
( 0.0
1
8.0
152)
0.483
587
( 0.0
1
9.0
73)
0.445
293
( 0.0
1
110.0
73)
0.412
301
( 0.0
1
3.0
32)
0.534
51
( 0.0
1
4.5
32)
0.534
77
( 0.0
4.5
32)
0.534
77
( 0.0
1
4.5
32)x
0.412
59
( 0.0
1
4.5
32)
0.412
59
( 0.0
1
4.5
32)
0.412
59
Sched.
Page Total 2150
Internal Gain Frac. Area Heat Gain Btu/hr
Li tits 1.00 x 1,162 X 0.000 Watts/sqft X 3.413 Btuh[Watt = 0
Occupants 1.00 X 1,162 x 0 Btuh/OCC. / 193 sgft/occ. = 0
Receptacle 1.00 x 1,162 x 0.000 Watts/sgft X 3.413 Btuh/Waft = 0
Process I�1 1.00 X 1,162 X 0.000 Wattts/sq�ft x 3.41 B�tuhfWatt = 00
Infiltration: �� 0011 x ( t,o6 x ,162 x �1-o_09J x L_ -o / 60] L 38 = B OJ
Schedule Air Sensible Area Ceiling Height ACH L\T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,3191
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occu antsL=1100
x 1 162 x 0 Btuh/OCC. / 193 sgft/occ. = 0
Receptacle x 1 162 x 0.000 Watts/sqft X 3.41 Btuh/Waft = o
Process X 1 162 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0
Infiltration: 1.00 X 4 771 x 1 162 x 10.00 x 0.00 / 60] 1 0.00000 = 0
-Schedule Air Latent Area Ceiling Height ACH &W
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 25 of 27
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Schenkman #2 8/19/2006
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area U -Value
DETD'
Zone 2
740F
112°F
380F
Btu/hr
1. Design Equivalent Temperature Difference (DETD)
Page Total 0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded
Unshaded
Solar Gain Orientation
Area SGF
Area SGF
SC Btu/hr
3060 fix
(West) (
18.0
X
1
+
0.0
X
73)
X
0.412
=
111
_3.0.8.0Jr.d
(West) (
48.0
X
1
+
0.0
X
73)
x
0.390
=
281
(
x
+
X
)X
(
x
+
X
)X
(
X
+
X
)X
=
(
X
+
X
)X
(
x
+
X
)X
=
(
X
+
X
)X
(
X
+
X
)X
Sched. Page Total 392
Internal Gain Frac. Area Heat Gain Btu/hr
Li hts 1.00 X 1,162 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0
Occupants 1.00 X 1,162 X 0 Btuh/OCC. / 193 sgft/occ. = 0
Receptacle 1.00 x 1,162 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Process 1.00 X X�1,1662�2 x�� 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: 00 x 1.064 x �_,,m x L_�0_QOJ x QQ1 / 60] 38 =
`schedule Air Sensible Area Ceiling Height ACH L\T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM g 31g
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants x 1 162 x 0 Btuh/occ. / 193 sgft/occ. = 0
Receptacle x 1 162 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Process r 11100 x 1 162 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0
Infiltration: I1 1.00 X 4,7711 X 1 162 X 10.00 x 0.00 /601 1 0.00000 = �0
`Schedule Air Latent Area Ceiling Height ACH LWy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o
EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 26 of 27
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Schenkman #2 8/19/2006
Project Title Date
Room Name Zone 3
Design Indoor Dry Bulb Temperature: 740F
Design Outdoor Dry Bulb Temperature: 112 0F
Design Temperature Difference: 380 F
Conduction
Area U -Value
X
1 0.02411
X
X
X
X
X
DETD 1
=
=
=
=
=
Btu/hr
55.0
1,234
38.0
201
34.6
707
34.6
636
38.0
1,232
1. Design Equivalent Temperature Difference (DETD) Page Total 4 011
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
2020 Skylight
(Skylight
2-020-Skylight
(Skylight)_
2020 Skylight
(Skylight)
5060 xo
3030 xo
(East)
(East)
5060 xo
(East)
294
( 0.0
1
4.0
152)
0.483
294
( 0.0
0.0
X
X
X
x
X
x
x
X
X
1
+
+
+
+
+
+
+
+
4.0
X
x
x
x
x
x
x
X
X
152)
X
x
X
x
x
x
x
)x
) X
0.483
=
=
=
=
=
=
=
294
( 0.0
1
4.0
152)
0.483
294
( 0.0
141+
4.0
152)
0.483
294
( 0.0
1
30.0
73)
0.668
1,463
( 0.0
1
9.0
73)
0.668
439
( 0.0
15
30.0
73)
0.668
1,463
(
(
-)
(
--
Sched.
Page Total alas
Internal Gain Frac. Area Heat Gain Btu/hr
Li ht5 1.00 x 945 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Occu ants 1.00 x 945 x 0 Btuh/OCC. / 236 sgft/OCc. = 0
Receptacle 1.00 x 945 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Process 1.00 x 945 x X0.000 Watts/�sgftfx 3.41 Btuh/Watt = 00
Infiltration: C o0 x 1.064 x 99.5 x [= oo I 0.001 x / 60]3.8 = E=o
Schedule Air Sensible Area Ceiling Height ACH Z -\T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,25d
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants d -111---
x say x 0 Btuh/occ. / 236 sgft/occ. = 0
Receptacle x 945 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Process x 945 x 0.000 Watts/sqft X 1 3.411 Btuh/Watt = o
Infiltration: 1.00 X 4 7t x 94 X Heigh X 60] 0.00000 =
Schedule Air Latent Area Ceiling Height ACH 4-\yy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0
Energ Pro 3.1 By EnergySoft User Number: 5732 Job Number: 3.1-1340 Page: 27 of 27