BRES2014-1086 Title 24OF*( CDRAMIM10 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lot 15-B Residence 81-413 Columbus Way La Quinta, CA 02253 Project Designer: Kristi Hanson Architects, Inc. 72-185 Painters Path Suite A Palm Desert , Ca 92260 760-776-4068 Report Prepared by: Butch White BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 RIE103 E-- T I IV E D OCT 17 2014 CITY OF LA QUINTA COMMUNITY DEVELOPM Job Number: Date: 10/3/2014 CITY OF AQTUINT BUILDING APPROVED FOR CONSTRUCTION DATE 2l BY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. �� .tom{�•F�:��'� I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 6.3 by EnergySoft Job Number: ID: User Number: 3665 1 2 3 21 24 27 34 41 48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 1 of 18 GENERAL INFORMATION 01 Project Name Private Residence 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Features shown'below 03 Project Location 81-413 Columbus Way 1�► 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 2253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 8922 15 Number of Zones 7 16 Slab Area (FT� 6859 17 (/v Number of Stories 3 18 Addition Cond. Floor Area NA ,1J� Natural Gas Available Yes 20 Addition Slab Area (FT) NA 0.0% Glazing Percentage (%) 24.0% COMPLIANCE RESULTS { v 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown'below 1�► IV ENERGY USE SUMMARY 04 05��" 06 07 08 Energy Use (kTDV/ft) Staf lord Rgs gn Proposed Design Compliance Margin Percent Improvement Space Heating 0 3.80 4.89 -1.09 -28.7% Space Cooling A. '-"-* 90.41 88.04 2.37 2.6% IAO Ventilation 1.27 1.27 0.00 0.0% Water Heating 3.04 3.65 -0.61 -20.1% Photovoltaic Offset ---- 0.00 0.00 Compliance Energy Total�� 98.52 97.85 0:6 O LA QU! N74�o Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09292014-651 BUILDING & SAFETY DEP-i . APPROVED FOR CONSTRUCTION DATE HES ��reeV Report Generated at`. 2014=10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03,.2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Cathedral Ceiling • Window overhangs and/or fins I HERS FEATURE SUMMARY CF1 R -PRF -01 Page 2 of 18 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: 01 • High Quality Insulation Installation (QII) 03 • IAQ mechanical ventilation 05 Cooling System Verifications: 07 • Verified EER Conditioned Floor Af (sft) • Verified SEER • Refrigerant Charge �0 • Fan Efficacy Watts/CFM Number of Ventilation Cooling Systems HVAC Distribution System Verifications: Private Residence • Duct Sealing 1 Domestic Hot Water System Verifications: 7 • Pipe Insulation, All Lines 2 ENERGY DESIGN RATING ♦ 10 This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part, '(such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energytise Energy Design Rating MarginPercent Improvement Total Energy (kTDV/f2)' 132.34; 131.67 0.67 0.5% includes calculated Appliances and Miscellaneous Energy Use (AMEUU) ,ems/ BUILDING - FEATURES INFORMATION 01 02 �" 03 04 05 06 07 Project Name Conditioned Floor Af (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Private Residence 8922 vV 1 21 7 1 2 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stand ra ds - 2013 Residential Compliance Report Version - CF1R-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 3 of 18 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC 11 1317 10 DHW Sys 1 Zone 2 Conditioned HVAC 22 1380 10 DHW Sys 1 Zone 3 Conditioned HVAC 33 599 10 DHW Sys 1 Zone 4 Conditioned HVAC 44 1369 10 DHW Sys 1 Zone 5 Conditioned HVAC 55 1005* 10 DHW Sys 1 ZONE 6 Conditioned HVAC 66 2053" 1 8 DHW Sys 1 Zone 7 Conditioned HVAC 77 W1.-199 8 1 DHW Sys 1 5p Registration Number: �� �fRegistration Date/Time: HERS Provider: CA Building Energy Efficiency Standa ds - 2013 Residential Compliance Report Version - CF113-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 4 of 18 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) NW Exterior Wall Zone 1 R-21 Wall 315 Right 755 25 90 SW Exterior Wall Zone 1 R-21 Wall 225 Back 140 100 90 SE Exterior Wall Zone 1 R-21 Wall 135 Left 140 0 90 Roof 2 Zone 1 R-38 Roof Attic 589 NW Exterior Wall 2 Zone 2 R-21 Wall 315 Right 50 27 90 SW Exterior Wall 2 Zone 2 R-21 Wall h225 Back 380 256 90 SE Exterior Wall 2 Zone 2 R-21 Wall W 135 Left 340 188.441 90 NE Exterior Wall Zone 2 R-21 Wall Y 45 Front 450 77.003 90 Roof 3 Zone 2 R-38 Roof Attic e ` 1380 NE Exterior Wall 2 Zone 3 R-21 Wall �" 45 Front 126 97.992 90 SW Exterior Wall 3 Zone 3 R-21 Wall UO J 225 Back 290 150 90 NW Exterior Wall 3 Zone 3 R-21 Wall.v 315 Right 100 31.008 90 Roof 4 Zone 3 R-38 Roof=Attic 599 NW Exterior Wall 4 Zone 4 R-21'Wall 315 Right 510 0 90 SE Exterior Wall 3 Zone 4 `14J41 Wall 135 Left 770 237.013 90 SW Exterior Wall 4 Zone 4 WR -21 Wall 225 Back 240 130 90 Roof 5 Zone 4 WFt-38 Roof Attic 1356.2 NE Exterior Wall 3 Zone 5 ,h%� R-21 Wall 45 Front 370 71 90 NW Exterior Wall 5 Zone 5 r R-21 Wall 315 Right 390 117.019 90 SE Exterior Wall 4 Zone 5 R-21 Wall 135 Left 380 52 90 SW Exterior Wall 5 Zone 5 �` R-21 Wall 225 Back 160 84.02 90 Roof 6 Zone 5 R-38 Roof Attic 1005 NE Exterior Wall 4 ZONE 6 '� R-21 Wall 45 Front 490 256.501 90 NW Exterior Wall 6 ZONE 6,.% R-21 Wall 315 Right 500 31.001 90 SE Exterior Wall 5 ZONE f3i R-21 Wall 135 Left 500 144.973 90 SW Exterior Wall 6 ZO�NE�6 R-21 Wall 225 Back 490 60.3901 90 Roof 7,IZ6NE 6 R-38 Roof Attic 2053 Interior Surface -Floor ZONE 6»Zone 7 R-30 Floor No Crawlspace 2053 NE Exterior Wall 5 Zone 7 R-21 Wall 45 Front 560 0 90 NW Exterior Wall 7 `�` Zone 7 R-21 Wall 315 Right 250 0 90 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stand' ds - 2013 Residential Compliance Report Version - CF1R-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 5 of 18 SE Exterior Wall 6 Zone 7 R-21 Wall 135 Left 250 0 90 SW Exterior Wall 7 Zone 7 R-21 Wall 225 Back 260 0 90 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectan ce Roof Emmittanc a Framin 9 Factor Roof Zone 4 R-38 Roof Attica specify - 2.9 1.4 2 0.17 9.46 0.1 0.85 0.07 :► ATTIC lQl� 01 02 03 05 06 07 Name Construction Roof Rise Roof%Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 2�� 0.1 0.85 Yes No ♦O� Registration Number: CA Building Energy Efficiency Stand ra ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 6 of 18 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading Window 08 Window NW Exterior Wall (Right -315) 5.0 5.0 1 25.0 0.39 0.24 Insect Screen (default) Window 09 Window SW Exterior Wall (Back -225) 10.0 2.0 1 20.0 0.39 0.24 Insect Screen (default) Window E1 Window SW Exterior Wall (Back -225) 10.0 8.0 1 80.0 0.54 0.24 Insect Screen (default) Window 10 Window NW Exterior Wall 2 (Right -315) 3.0 9.0 1 27.0 0.39 0.24 Insect Screen (default) Window 11 Window SW Exterior Wall 2 (Back -225) 50.0 < 2.0 0.1 10.0 0.39 0.24 Insect Screen (default) Window 12 Window SW Exterior Wall 2 (Back -225) 4.5 2.0 1 9.0 0.39 0.24 Insect Screen (default) Window 13 Window SW Exterior Wall 2 (Back -225) 4.5�� 2.0 1 9.0 0.39 0.24 Insect Screen (default) Window 14 Window SW Exterior Wall 2 (Back -225) X5:0 2.0 1 10.0 0.39 0.24 Insect Screen (default) Window S-1 Window SW Exterior Wall 2 (Back -225) ;Q§21.8 10.0 1 218.0 0.54 0.24 Insect Screen (default) Window 15 Window SE Exterior Wall 2 (Left -135) �� 5.5 2.0 1.091 12.0 0.39 0.24 Insect Screen (default) Window 16 Window SE Exterior Wall 2 (Left -135) V 4.5 2.0 1 9.0 0.39 0.24 Insect Screen (default) Window 17 Window SE Exterior Wall 2 (Left -135) �" 5.0 2.0 1 10.0 0.39 0.24 Insect Screen (default) Window F2 Window SE Exterior Wall 2 (Left -135) 16.0 10.0 0.984 157.4 0.54 0.24 Insect Screen (default) Window 04 Window NE Exterior Wall (Front -45). 69 3.0 7.0 1 21.0 0.39 0.24 Insect Screen (default) Window 05 Window NE Exterior Wall (Front -458, 3.0 7.0 1 21.0 0.39 0.24 Insect Screen (default) Window 06 Window NE Exterior Wall (Front 17.8 2.0 0.986 35.0 0.39 0.24 Insect Screen (default) Window 02 Window NE Exterior Wall 2 (F�,rpo�nt-45) 3.0 10.0 1 30.0 0.39 0.24 Insect Screen (default) Window 03 Window NE Exterior Wall 2�(.F.6t-45) 7.8 2.0 0.968 15.0 0.39 0.24 Insect Screen (default) Window 61 Window NE Exterior Wal ' AFront-45) 5.2 10.0 1.019 53.0 1.28 0.80 Insect Screen (default) Window G1 Window SW Exterior Wall 3 (Back -225) 12.5 10.0 1 125.0 0.54 0.24 Insect Screen (default) Window 18 Window SW Extehor)Wall 3 (Back -225) 12.5 2.0 1 25.0 0.39 0.24 Insect Screen (default) Window 56 Window NW Ezt�rior Wall 3 (Right -315) 3.8 6.0 1.009 1 23.0 0.56 0.25 Insect Screen (default) Window 57 Window NW Ezierior Wall 3 (Right -315) 3.8 2.0 1.053 8.0 0.39 0.24 Insect Screen (default) Window 20 Window qS I ttxterior Wall 3 (Left -135) 4.5 2.0 1 9.0 0.39 0.24 Insect Screen (default) Window 21 Window %SE Exterior Wall 3 (Left -135) 6.0 2.0 1 12.0 0.39 0.24 Insect Screen (default) Window 22 Window SE Exterior Wall 3 (Left -135) 4.5 2.0 1 9.0 0.39 0.24 Insect Screen (default) Window 23 Window SE Exterior Wall 3 (Left -135) 5.5 5.0 1 27.5 0.39 0.24 Insect Screen (default) Window 24 Window SE Exterior Wall 3 (Left -135) 5.5 2.0 1 11.0 0.39 0.24 Insect Screen (default) Window 25 WindowSE Exterior Wall 3 (Left -135) 13.0 9.0 0.889 104.0 0.39 0.24 Insect Screen (default) Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Datefrime: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 156.xml CF1 R -PRF -01 Page 7 of 18 Window 26 Window SE Exterior Wall 3 (Left -135) 13.0 2.0 1 26.0 0.39 0.24 Insect Screen (default) Window 27 Window SE Exterior Wall 3 (Left -135) 5.5 5.0 1 27.5 0.39 0.24 Insect Screen (default) Window 28 Window SE Exterior Wall 3 (Left -135) 5.5 2.0 1 11.0 0.39 0.24 Insect Screen (default) Window H1 Window SW Exterior Wall 4 (Back -225) 13.0 8.0 1 104.0 0.54 0.24 Insect Screen (default) Window 19 Window SW Exterior Wall 4 (Back -225) 13.0 2.0 1 26.0 0.39 0.24 Insect Screen (default) Skylight S05-47 Skylight Roof ( specify --45) 1 1.4 0.30 0.30 Skylight S06-48 Skylight Roof (- specify --45) 1 1.4 0.30 0.30 Window 32 Window NE Exterior Wall 3 (Front -45) 5.0 2.0 1 10.0 0.39 0.24 Insect Screen (default) Window 36 Window NE Exterior Wall 3 (Front -45) 1.0 5.0 1 5.0 0.39 0.24 Insect Screen (default) Window 37 Window NE Exterior Wall 3 (Front -45) 8.0 w�Q y 2.0 1 16.0 0.39 0.24 Insect Screen (default) Window 38 Window NE Exterior Wall 3 (Front -45) 5'9 6.0 1 30.0 0.56 0.25 Insect Screen (default) Window 39 Window NE Exterior Wall 3 (Front -45) '5o 2.0 1 10.0 0.39 0.24 Insect Screen (default) Window 40 Window NW Exterior Wall 5 (Right 315)3.8 6.0 1.053 24.0 0.71 0.73 Insect Screen (default) Window 41 Window NW Exterior Wall 5 (Right -315) 3.8 2.0 1.053 8.0 0.39 0.24 Insect Screen (default) Window 42 Window NW Exterior Wall 5 (Right -315) 1%4' 3.8 6.0 1.009 23.0 0.56 0.25 Insect Screen (default) Window 43 Window NW Exterior Wall 5 (Right -315) 3.8 2.0 1.053 8.0 0.39 0.24 Insect Screen (default) Window 48 Window NW Exterior Wall 5 (Right -315) �` 4.8 8.0 1 38.0 0.39 0.24 Insect Screen (default) Window 49 Window NW Exterior Wall 5 (Right -315) 8.0 2.0 1 16.0 0.39 0.24 Insect Screen (default) Window 29 Window SE Exterior Wall 4 (Left -l* 30.0 5.0 0.1 15.0 0.56 0.25 Insect Screen (default) Window 30 Window SE Exterior Wall 4 (LeftpJ 5) 9.0 2.0 1 18.0 0.39 0.24 Insect Screen (default) Window 31 Window SE Exterior Wall 4 (LWl35) 1.0 5.0 1 5.0 0.39 0.24 Insect Screen (default) Window 33 Window SE Exterior Wall,�(Left 135) 1.0 5.0 1 5.0 0.39 0.24 Insect Screen (default) Window 34 Window SE Exterior VY40F(Left 135) 1.0 2.0 1 2.0 0.39 0.24 Insect Screen (default) Window 35 Window SE Exterior] W it 4 (Left -135) 3.5 2.0 1 7.0 0.39 0.24 Insect Screen (default) Window 44 Window SW Exterior Wall 5 (Back -225) 3.8 6.0 1.009 23.0 0.56 0.25 Insect Screen (default) Window 45 Window SW Exterior Wall 5 (Back -225) 3.8 2.0 1.053 8.0 0.39 0.24 Insect Screen (default) Window 46 Window SW Exterior Wall 5 (Back -225) 4.8 8.0 0.974 37.0 0.39 0.24 Insect Screen (default) Window 47 Window (SW-txterior Wall 5 (Back -225) 8.0 2.0 1 16.0 0.39 0.24 Insect Screen (default) Window 65 Window A&NE Exterior Wall 4 (Front -45) 9.0 6.0 1 54.0 0.39 0.24 Insect Screen (default) Window 66 Window O NE Exterior Wall 4 (Front -45) 9.0 6.0 1 54.0 0.56 0.25 Insect Screen (default) Window P1 Window NE Exterior Wall 4 (Front -45) 16.7 9.0 0.991 148.5 0.54 0.24 Insect Screen (default) Window 67 Window , �' NW Exterior Wall 6 (Right -315) 5.5 2.0 1.091 12.0 0.39 0.24 Insect Screen (default) Window 68 Window NW Exterior Wall 6 (Right -315) 3.5 2.0 1 7.0 0.39 0.24 Insect Screen (default) Registration Number: CA Building Energy Efficiency Stand ra ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 8 of 18 Window 69 Window NW Exterior Wall 6 (Right -315) 6.0 2.0 1 12.0 0.39 0.24 Insect Screen (default) Window 58 Window SE Exterior Wall 5 (Left -135) 13.9 9.0 0.983 123.0 0.39 0.24 Insect Screen (default) Window 63 Window SE Exterior Wall 5 (Left -135) 5.5 2.0 1 11.0 0.39 0.24 Insect Screen (default) Window 64 Window SE Exterior Wall 5 (Left -135) 5.5 2.0 1 11.0 0.39 0.24 Insect Screen (default) Window 59 Window SW Exterior Wall 6 (Back -225) 3.8 7.3 1.034 28.5 0.39 0.24 Insect Screen (default) Window 60 Window SW Exterior Wall 6 (Back -225) 3.8 2.0 1.026 7.8 0.39 0.24 Insect Screen (default) Window 61 Window SW Exterior Wall 6 (Back -225) 6.5 2.0 0.985 12.8 0.39 0.24 Insect Screen (default) Window 62 Window SW Exterior Wall 6 (Back -225) 3.5 2.0 1 7.0 0.39 0.24 Insect Screen (default) Window 73 Window SW Exterior Wall 6 (Back -225) 4.2 < 1.0 1.024 4.3 0.39 0.24 Insect Screen (default) 074- DOORS 7 DOORS A 01 02 � 03 04 Name Side of Building Area (ft2) U -factor Door C1 NE Exte�io� Wall 5 74.0 0.50 Door C2 NE Exterior Wall 5 148.0 0.50 Door C3 NE Exterior Wall 5 74.0 0.50 ♦O� Registration Number: �f+� CA Building Energy Efficiency Stan�da ds - 2013 Residential Compliance Registration Date/Time: Report Version - CFSR-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 9 of 18 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 08 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 09 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window El 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 10 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 11 10 0.1 10 10 0 S0, 0 0 0 0 0 0 0 Window 12 10 0.1 10 10 0 p�0 0 0 0 0 0 0 0 Window 13 10 0.1 10 10 0" 0 0 0 0 0 0 0 0 Window 14 10 0.1 10 10 0 0 0 0 1 0 0 0 0 0 Window S-1 10 0.1 10 10 0001"y0 0 0 0 0 0 0 0 Window 15 10 0.1 10 10 `OJ 0 0 0 0 0 0 0 0 Window 16 10 0.1 10 10 evo 0 0 0 0 0 0 0 0 Window 17 10 0.1 10 10 < 0 0 0 0 0 0 0 0 0 Window F2 10 0.1 10 10,0 0 0 0 0 0 0 0 0 Window 04 10 0.1 10 OA v 0 0 0 0 0 0 0 0 0 Window 05 10 0.1 10 r—ib 0 0 0 0 0 0 0 0 0 Window 06 10 0.1 10v 10 0 0 0 0 0 0 0 0 0 Window 02 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 03 10 0.1 110 10 0 0 0 00 0 0 0 0 Window 61 10 0.1 410 10 0 0 0 0 0 0 0 0 0 Window G1 10 0.1 (1110 10 0 0 0 0 0 0 0 0 0 Window 18 10 0.1 44" 10 10 0 0 0 0 0 0 0 0 0 Window 56 10 0.1v 10 10 0 4 0 0.1 0 0 0 0 0 Window 57 10 60 10 10 0 4 0 0.1 0 0 0 0 0 Window 20 8^i 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 21 8 eG� 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 22 8 ��` 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 23 k8��v 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 248 0.1 8 8 0 0 0 0 0 0 0 0 0 Registration Number: A� CA Building Energy Efficiency Stan' ads - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/rime: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 10 of 18 Window 25 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 26 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 27 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 28 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window H1 8 0.1 1 8 8 0 0 0 0 0 0 0 0 0 Window 19 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 32 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 36 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 37 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 38 4 0.1 4 4 0 0 0 0 0 0 0 0 Window 39 4 0.1 4 4 0 �0 0 0 0 0 0 0 0 Window 40 4 0.1 4 4 0 Ito 0 0 0 0 0 0 0 0 Window 41 4 0.1 4 4 0 `� J 0 0 0 0 0 0 0 0 Window 42 4 0.1 4 4 0� 0 0 0 0 0 0 0 0 Window 43 4 0.1 4 4 W'0" 0 0 0 0 0 0 0 0 Window 48 4 0.1 4 4 0-0 0 0 0 0 0 0 0 0 Window 49 4 0.1 4 4 `L` 0 0 0 0 0 0 0 0 0 Window 29 4 0.1 4 4# 0 0 0 0 0 0 0 0 0 Window 30 4 0.1 4 0 0 0 0 0 0 0 0 0 Window 31 4 0.1 4 'OOV.4 0 0 0 0 0 0 0 0 0 Window 33 4 0.1 4 Iry 4 0 0 0 0 0 0 0 0 0 Window 34 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 35 4 0.1 �4 % 4 0 0 0 0 0 0 0 0 0 Window 44 4 0.1 �`�'4 4 0 0 0 0 0 0 0 0 0 Window 45 4 0.1 t 4 4 0 0 0 0 0 0 0 0 0 Window 46 4 0.1 `� 4 4 0 0 0 0 0 0 0 0 0 Window 47 4 4 4 0 0 0 0 0 0 0 0 0 Window 65 401 4 4 0 0 0 0 0 0 0 0 0 Window 66 4 ,'Y0.1 4 4 0 0 0 0 0 0 0 0 0 Window P1 8 i 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 67 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 68 0.1 4 4 0 0 0 0 0 0 0 0 Window 69 V'4 0.1 4 14 0 0 10 --40 0 0 10 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stant ds - 2013 Residential Compliance Report Version - CF111-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 11 of 18 Window 58 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 63 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 64 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 59 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 60 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 61 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 62 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 73 4 0.1 4 4 0 0 0 0 0 0 0 0 0 O. OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type FramingtV ' Total Cavity R -value Assembly Layers 2x4 Top CHoni of Cavity/ Frame: no insul. /2x4 Top Chrd Roof Truss@24 in. r Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling OIC. none Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls Wood Framed Wall @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceilin%, 2x4 @ 24 in. O.C. R 38 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board • Cavity/ Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Attici Cathedral Ceilings Wood Frame0ceiling 2x4 @ 24 in. O.C. R 38 Roofing: Light Roof (Asphalt Shingle) Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking • Cavity / Frame: R-25 /2x10 R-30 Floor No Crawlspace Interior Floors Wood Framed Floor 2x10 @ 16 in. O.C. R 25 Ceiling Below Finish: Gypsum Board 9 .A0 Registration Number: A� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF113-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 12 of 18 SLAB FLOORS 01 02 103' 04 05 06 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Slab -on -Grade Zone 1 1317 89.5 None 1 No Slab -on -Grade 2 Zone 2 1380 113 None 1 No Slab -on -Grade 3 Zone 3 599 50 None 1 No Slab -on -Grade 4 Zone 4 1359 91 None 1 No Slab -on -Grade 5 Zone 5 1005 75 None 1 No Slab -on -Grade 6 Zone 7 1199 b1107 None 1 No BUILDING ENVELOPE - HERS VERIFICATION QA`i► 01 02 03 04 Quality Insulation Installation (OII) Quality Installation of Spray Foam Insu�lati'on Building Envelope Air Leakage ACH @ 50 Pa Required Not Required �� Not Required --- WATER HEATING SYSTEMS Aw 01 02 103' 04 05 06 Name System Type Disth6ution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW (HER S'd) Pipe Insulation, All q DHW Heater 1 1 Annual Large Storage 60 Lines 120000-Btu/hr 0 0.021 DHW Heater 1 Natural Gas ri (Hq�S req'd) Pipe Insulation, All 60 0.994 120000-Btu/hr DHW Sys 1 DHW Lines DHW Heater 1 2 Annual ^� I` WATER HEATERS `V 01 02 r 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas 097R Large Storage 60 0.994 120000-Btu/hr 0 0.021 DHW Heater 1 Natural Gas ri Large Storage 60 0.994 120000-Btu/hr 0 0.021 •may Registration Number: CA Building Energy Efficiency Stanch ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 13 of 18 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 Pipe Insulation, All Lines N/A N/A Pipe Insulation, All Lines N/A N/A DHW Sys 1 -1/2 Pipe Insulation, All Lines N/A N/A Pipe Insulation, All Lines N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System �� Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC 11 Other Heat/Cool Heating Component 1 ♦ �" Yes, Cooling Component 1 Yes Air Distribution 1317 System 1 Air DistributionSystem HVAC 22 Other Heat/Cool Heating Component 2 Yes Cooling Component 2 Yes 2 1380 HVAC 33 Other Heat/Cool Heating Component 34'� Yes Cooling Component 3 Yes Air Distribution System 3 599 HVAC 44 Other Heat/Cool Heating Componen`i14 � Yes Cooling Component 4 Yes Air Distribution System 4 1369 HVAC 55 Other Heat/Cool Heating Comoohent 5 Yes Cooling Component 5 Yes Air Distribution System 5 1005 HVAC 66 Other Heat/Cool Heating,Component 6 Yes Cooling Component 6 Yes Air Distribution 2053 System 6 HVAC 77 Heat Pump Heat., ' mp System 7 No Heat Pump System 7 No None 1199 HVAC 77 Heat Pump H`ea'd Pump System 7 No Heat Pump System 7 No None 1199 ICU'* ®* ♦O� Registration Number: CA Building Energy Efficiency Stand rds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 14 of 18 HVAC - HEATING SYSTEMS 01 02 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 98 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 98 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 98 AFUE Heating Component 4 CntrlFurnace - Fuel -fired central furnace 98 AFUE Heating Component 5 CntrlFurnace - Fuel -fired central furnace 98 AFUE Heating Component 6 CntrlFurnace - Fuel -fired central furnace 98 AFUE off; HVAC - HEATING SYSTEMS: Heat Pumps &% 01 02 03 04 1 VA65 06 07 08 09 10 04 05 Heating `Q� Cooling Zonally Multispeed HERS Name Type HSPF/COP Cap 4'WCap 17 SEER EER Controlled Compressor Verification Heat Pump System 7 Ductless HeatPump 10 HSPF 36200 27300 18 12.5 No Yes Heat Pump System �► 7 -hers -cool �r Heat Pump System Heat Pump System 7 Ductless HeatPump 10 HSPF W-36200 27300 18 12.5 No Yes 7 -hers -cool ♦0w HVAC HEAT PUMP COOLING - HERS VERIFICATION of 01 02 V 03 04 05 Name Verified Airtlow Verified EER Verified SEER Verified Refrigerant Charge HVAC 77 SCSysRpt 1 Not Re�uWed �� Not Required Required Not Required HVAC 77 SCSysRpt 2 Not Required Not Required Required Not Required ♦ 0 Registration Number: A�S Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 15 of 18 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 02 V03 Efficiency 05 Multi -speed Name Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 13 20 No Yes Cooling Component 350 system Required Required Cooling Component 3 -hers -cool Required 1-herscool Cooling Component 2 SplitAirCond - Split air conditioning 13 20 No Yes Cooling Component Required system Cooling Component 5 -hers -cool Required 350 Required 2 -hers -cool Cooling Component 3 SplitAirCond - Split air conditioning 14 24 No Yes Cooling Component Heat Pump System 7 -hers -cool system Not Required Required Not Required 3 -hers -cool Cooling Component 4 SplitAirCond - Split air conditioning 13 20� No Yes Cooling Component system 4 -hers -cool Cooling Component 5 SplitAirCond - Split air conditioning�+ 14 21 No Yes Cooling Component system • �� 5 -hers -cool Cooling Component 6 SplitAirCond - Split air conditioning 130 20 No Yes Cooling Component system 6 -hers -cool V HVAC COOLING - HERS VERIFICATION 01 02 V03 04 05 06 Name Verified Airflow • � Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required Cooling Component 2 -hers -cool Required 350 Required Required Required Cooling Component 3 -hers -cool Required 350 Required Required Required Cooling Component 4 -hers -cool Required 350 Required Required Required Cooling Component 5 -hers -cool Required 350 Required Required Required Cooling Component 6 -hers -cool Required �„ 350 Required Required Required Heat Pump System 7 -hers -cool Not Required Not Required Required Not Required KM .0 Registration Number: A� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 16 of 18 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 *Ik� Verified Duct Design Low -leakage Supply Duct Verification Duct Leakage Target (%) Verified Duct Location Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 2 -hers -dist Air Distribution System 3 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 3 -hers -dist 6.0 Not Required Not Required Not Required 3 -hers -dist Air Distribution Air Distribution System 4 Ducts located in attic Sealed and tested 8Attic Air Distribution System Attic None System 4 -hers -dist Not Required Not Required --- (� Air Distribution Air Distribution System 5 Ducts located in attic Sealed and tested 8 �� Attic Attic None System 5 -hers -dist Air Distribution System 6 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution Air Distribution System y Required 6.0 Not Required Not Required Not Required System 6 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION ^� 01 02 03 04 05 06 07 Duct Leakage *Ik� Verified Duct Design Low -leakage Name Verification Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System Required �V6.0 Not Required Not Required Not Required --- 1 -hers -dist Air Distribution System Required q V0� 6.0 Not Required Not Required Not Required --- 2 -hers -dist Air Distribution System Required�v 6.0 Not Required Not Required Not Required 3 -hers -dist Air Distribution System Required (� e V 6.0 Not Required Not Required Not Required --- 4 -hers -dist Air Distribution System Required 6.0 Not Required Not Required Not Required --- 5-hers-dist Air Distribution System y Required 6.0 Not Required Not Required Not Required 6 -hers -dist Now .0 Registration Number: A�® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CF1 R -PRF -01 Page 17 of 18 HVAC -FAN SYSTEMS &A 02 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan 6 -hers -fan GZI HVAC FAN SYSTEMS - HERS VERIFICATION &A 02 01 02 03 Name VerifiedF�anWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan ►. `'� Required 0.58 HVAC Fan 3 -hers -fan �� Required 0.58 HVAC Fan 4 -hers -fan Required 0.58 HVAC Fan 5 -hers -fan . Required 0.58 HVAC Fan 6 -hers -fan Required 0.58 IAO (Indoor Air Quality) FANS v 01 02 W 03 04 05 06 Name �( IAO CFM IAQ Watts/CFM IAO Fan Type IAO Recovery Effectiveness(%) HERS Verification DwellingUnit 254.22 0- 0.25 Default 0 Required U COOLING VENTILATION k 01 '00 02 03 04 05 Name ^tooling Vent CFM Cooling Vent Watts/CFM Number of Fans HERS Verification WH Fan 1 4W 80 0.025 1 Required Registration Number:r, Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09292014-651 Report Generated at: 2014-10-03 14:01:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Private Residence Calculation Date/Time: 13:56, Fri, Oct 03, 2014 Calculation Description: Title 24 Analysis Input File Name: Lot 15B.xml CFI R -PRF -01 Page 18 of 18 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature:. Butch White Company: Signature Date: BREEZE AIR CONDITIONING 10/3/2014 Address: CEA/HERS Certification Identification (If applicable): 75-145 St. Charles Place City/statePalm Desert, CA 92211 Phone: 7600-346-0855 XW RESPONSIBLE PERSON'S DECLARATION STATEMENT(/ I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility fort a building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate gf;.Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: 4C�' Responsible Designer Signature: Christopher Kidney . G� Company: Date Signed: to Kristi Hanson Architects, Inc. Address: �`� License: � �'�,' ,p f ,� % I 72-185 Painters Path Suite A �� � City/State/Zip: r`N Phone: Palm Desert , Ca 92260 i� 760-776-4068 .may Registration Number: CA Building Energy Efficiency Stantlbrds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09292014-651 HERS Provider: Report Generated at: 2014-10-03 14:01:06 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Lot 15-B Residence Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/3/2014 Project Address 81-413 Columbus Way La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,922 Addition n/a # of Units 7 INSULATION Construction Type Area Cavity Special Features Status Wall Wood Framed R 21 10,274 New Roof Wood Framed Attic R 38 6,982 Cool Roof New Slab Unheated Slab -on -Grade - no insulation 6,859 Perim = 526' New Demising Wood Framed w/o Crawl Space R 25 2,053 New Door Opaque Door - no insulation 296 New FENESTRATION Orientation Area I Total Area: 2,139 Glazing Percentage: 24-0%1 U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.49 Exterior Shades Status Right (NKq 25.0 0.390 0.24 2.0 none Bug Screen New Rear (SVtq 46.0 0.390 0.24 8.0 none Bug Screen New Rear (SVtq 184.0 0.540 0.24 8.0 none Bug Screen New Right (NVtq 27.0 0.390 0.24 10.0 none Bug Screen New Rear (SW) 63.0 0.390 0.24 10.0 none Bug Screen New Rear (SVtq 343.0 0.540 0.24 10.0 none Bug Screen New Left (SE) 31.0 0.390 0.24 10.0 none Bug Screen New Left (SE) 157.5 0.540 0.24 10.0 none Bug Screen New Front (NE) 122.0 0.390 0.24 10.0 none Bug Screen New Front (NE) 53.0 1.280 0.80 10.0 none Bug Screen New Right (NIAq 23.0 0.560 0.25 10.0 4.00/0.00 Bug Screen New Right (NVIq 8.0 0.390 0.24 10.0 4.00/0.00 Bug Screen New Left (SE) 237.0 0.390 0.24 8.0 none Bug Screen New Skylight 1.4 0.300 0.30 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 98% AFUE Split Air Conditioner 20.0 SEER Setback New 1 Central Furnace 98% AFUE Split Air Conditioner 20.0 SEER Setback New 1 Central Furnace 98% AFUE Split Air Conditioner 24.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 1 Ducted Ducted Attic 8.0 New HVAC 2 Ducted Ducted Attic 8.0 New HVAC 3 Ducted Ducted Attic 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Large Storage Gas 60 0.99 All Pipes Ins (HERS) New Ene Pro 6.3 by Ener Soft User Number: 3665 Runcode: 2014-10-03T14:02:35 ID: Page 21 of 59 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Lot 15-8 Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/3/2014 Project Address 81-413 Columbus Way La Quinta Cal ifomia Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,922 Addition n/a # of Units 7 INSULATION Construction Type Area Cavity Special Features Status FENESTRATION Orientation Area I Total Area: 2,139 Glazing Percentage: 24.0%1 U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.49 Exterior Shades Status Skylight 1.4 0.300 0.30 none none None New Front (NE) 95.0 0.390 0.24 4.0 none Bug Screen New Front (NE) 84.0 0.560 0.25 4.0 none Bug Screen New Right (NVIO 24.0 0.710 0.73 4.0 none Bug Screen New Right (NVI0 101.0 0.390 0.24 4.0 none Bug Screen New Right (NV19 23.0 0.560 0.25 4.0 none Bug Screen New Left (SE) 15.0 0.560 0.25 4.0 none Bug Screen New Left (SE) 182.0 0.390 0.24 4.0 none Bug Screen New Rear (SV1) 23.0 0.560 0.25 4.0 none Bug Screen New Rear (SVA) 121.4 0.390 0.24 4.0 none Bug Screen New Front (NE) 148.5 0.540 0.24 8.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 98% AFUE Split Air Conditioner 20.0 SEER Setback New 1 Central Furnace 98% AFUE Split Air Conditioner 21.0 SEER Setback New 1 Central Furnace 98% AFUE Split Air Conditioner 20.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 4 Ducted Ducted Attic 8.0 New HVAC 5 Ducted Ducted Attic 8.0 New HVAC 6 Ducted Ducted Attic 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 6.3 by EnerqySoft User Number., 3665 RunCode: 2014-10-03T14:02:35 ID: Page 22 of 59 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Lot 15-B Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/3/2014 Project Address 81-413 Columbus Way La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,922 Addition n/a # of Units 7 INSULATION Construction Type Area Cavity Special Features Status FENESTRATION Orientation Area I Total Area: 2,139 Glazing Percentage: 24.0 % I New/Altered Average U -Factor: 0.49 U -Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 7 Ductless / with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ene Pro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03714:02:35 /D: Page 23 of 59 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Lot 15-B Residence 1101312014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoR User Number: 3665 ID: Page 24 of 59 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Lot 15-8 Residence 10/3/2014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number. 3665 ID: Page 25 of 59 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Lot 15-8 Residence 10/3/2014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftZ or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130. 1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoft User Number: 3665 ID: Page 26 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 1 Floor Area 1,317 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 537 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 88,200 11,137 1,800 381 11,740 Total Output Btuh 88,200 0 Output Btuh/s ft 67.0 525 448 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 58,000 190 1,800 -190 Total Output ons 4.8 525 448 Total Output Btuh/s ft 44.0 Total Output s ft/Ton 272.5 1 12,377 12,446 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 Lennox XC25-060-230-" 43,962 5,125 88,200 Airflow cfm/s ft 0.76 Airflow cfm/Ton 206.9 Outside Air % 0.0% Total Adjusted System Output 43,962 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,125 Aug 3 PM 88,200 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air to 0 cfm 68 OF 68 OF 97 OF 97 OF 10 Heating Coil Supply Fan 97 OF 1,000 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 75/62°F 75/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 56 / 54 OF 1,000 cfm 47.8% ROOM 75/62°F EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 201410-03T14:02:35 /D: Page 27 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 2 Floor Area 1,380 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,014 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 88,200 20,573 1,886 708 21,551 Total Output Btuh 88,200 0 Output Btuh/s ft 63.9 969 823 Cooling System 0 0 Output perSystem 58,000 0 0 0 0 Total Output Btuh 58,000 190 969 22.702 F 1,886 -190 Total Output ons 4.8 823 Total Output Btuh/s ft 42.0 F23,006 Total Output s ft/Ton 285.5 Air System CFM perSystem 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 Lennox XC25-060-230-" 44,090 5,111 88,200 Airflow cfm/s ft 0.72 Airflow cfm/Ton 206.9 Outside Air % 0.0% Total Adjusted System Output 44.090 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 5,111 Aug 3 PM 88,200 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 of Outside Air No 0 cfm 67 of 67 of 97 OF 97 OF 10 Heating Coil Supply Fan 96 of 1,000 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76/62oF 76/62oF 55/54°F 55/54OF Cooling Coil Supply Fan 56 / 54 OF 1,000 cfm 47.8% ROOM 75/62OF EnergyPro 6.3 by EnergySoff User Number: 3665 RunCode: 201410-03714:02:35 ID: Page 28 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 3 Floor Area 599 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 780 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 68,600 15,526 818 385 11,802 Total Output Btuh 68,600 0 Output Btuh/s ft 114.5 732 451 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output Btuh 24,000 190 818 -190 Total Output ons 2.0 732 451 Total Output Btuh/s ft 40.1 Total Output s ft/Ton 299.5 1 17,179 12,513 Air System CFM per System 600 HVAC EQUIPMENT SELECTION Airflow cfm 600 Lennox XC25-024-230-** 17,736 2,584 68,600 Airflow cfm/s ft 1.00 Airflow cfm/Ton 300.0 Total Adjusted System Output 17,736 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 2,584 68,600 Aug 3 PM Jan 1 AM Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4 V- 0 cfm 67 OF 67 OF 97 OF 97 OF M Supply Fan Heating Coil 97 OF 600 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air A._ 0 cfm 76/62°F 76/62°F 55/54°F 55/54°F 0, Cooling Coil Supply Fan 56 / 54 OF 600 cfm 47.1 % ROOM 75/62°F EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03714:02:35 /D: Page 29 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 4 Floor Area 1,369 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 834 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 88,200 17,059 1,871 574 17,572 Total Output Btuh 88,200 0 Output Btuh/s ft 64.4 804 671 Cooling System 0 0 Output perSystem 58,000 0 0 0 0 Total Output Btuh 58,000 190 1,871 -190 Total Output ons 4.8 804 671 Total Output Btuh/s ft 42.4 Total Output s ft/Ton 283.2 1 18,857 18,723 Air System CFM perSystem 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 LennoxXC25-060-230-" 44,031 5,132 88,200 Airflow cfm/s ft 0.73 Airflow cfm/Ton 206.9 Outside Air % 0.0% Total Adjusted System Output 44,031 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,132 Aug 3 PM 88,200 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4 V- 0 cfm 67 OF 67 OF 97 OF 97 OF f 0 M Heating Coil Supply Fan 97 OF 1,000 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76 / 62 OF 76/62°F 55/54°F 55/54°F ail Cooling Coil Supply Fan 56 / 54 OF 1,000 cfm 47.8% ROOM 75 / 62 OF EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03714:02:35 /D: Page 30 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 5 Floor Area 1,005 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 793 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 88,200 16,173 1,373 480 14,896 Total Output Btuh 88,200 0 Output Btuh/s ft 87.8 762 569 Cooling System 0 0 Output perSystem 48,500 0 0 0 0 Total Output Btuh 48,500 510 1,373 -510 Total Output ons 4.0 762 569 Total Output Btuh/s ft 48.3 Total Output s ft/Ton 248.7 1 18,206 115,523 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Lennox XC25-048-230-" 35,617 5,297 88,200 Airflow cfm/s ft 1.19 Airflow cfm/Ton 296.9 Outside Air % 0.0% Total Adjusted System Output 35,617 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 5,297 Aug 3 PM 88,200 r Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 4V- 0 cfm 68 OF 68 OF 97 OF 97 OF f iC��Tr' M Heating Coil Supply Fan 1,200 cfm 97 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air 0 cfm 76/62°F 76/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 56 / 54 OF 1,200 cfm 47.0% ROOM 75/62°F EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03T14:02:35 /D: Page 31 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 6 Floor Area 2,053 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,327 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 88,200 26,542 2,805 683 20,830 Total Output Btuh 88,200 0 Output Btuh/s ft 43.0 1,251 795 Cooling S stem 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 58,000 190 2,805 -190 Total Output ons 4.8 1,251 795 Total Output Btuh/s ft 28.3 Total Output s ft/Ton 424.8 1 29,234 22,230 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 Lennox XC25-060-230-" 43,602 5,910 88,200 Airflow cfm/s ft 0.49 Airflow cfm/Ton 206.9 Total Adjusted System Output 43,602 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,910 88,200 Aug 3 PM Jan 1 AM Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 101 Outside Air 0 cfm 67 OF 67 OF 97 OF 97 OF f n:� Heating Coil Supply Fan 96 OF 1,000 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76/63°F 76/63°F 55/54°F 55/54°F Cooling Coil Supply Fan 56 / 54 OF 1,000 cfm 48.9% ROOM 75/62°F EnergyPro 6.3 by EnergySoft User Number 3665 RunCode: 2014-10.03714:02:35 ID: Page 32 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 15-B Residence Date 10/3/2014 System Name HVAC 7 Floor Area 1,199 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK CFM Sensible Total Room Loads 558 11,789 Return Vented Lighting 0 Return Air Ducts 0 Return Fan 0 Ventilation 0 0 Supply Fan 381 Supply Air Ducts 0 TOTAL SYSTEM LOAD 1 12,170 COIL HTG. Latent CFM 1,638 489 0 0 1,638 PEAK Heating System Sensible Output perSystem 36,200 15,367 Total Output Btuh 72,400 Output Btuh/s ft 60.4 0 Cooling System_ 0 Output perSystem 27,300 0 Total Output Btuh 54,600 -381 Total Output ons 4.6 0 Total Output Btuh/s ft 45.5 Total Output s ft/Ton 263.5 14,986 Air System CFM perSystem 600 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Fujitsu Mini Split 24RLXFW/AOU24 45,997 0 45,219 Airflow cfm/s ft 1.00 2.4 kW Supplemental Electric 16,246 Airflow cfm/Ton 263.7 61,465 Jan 1 AM Outside Air % 0.0 % Total Adjusted System Output 45,997 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 OF 97 OF 97 OF 97 OF C Heating Coil Aux. Heat Coil Supply Fan 97 OF 1,200 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 75/62°F 75/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 1,200 cfm 47.3% 55 / 54 OF ROOM 75/62°F EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 201410-03714:02:35 ID: Page 33 of 59 ROOM LOAD SUMMARY Project Name Date Lot 15-8 Residence 10/3/2014 System Name Floor Area HVAC 1 1,317 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult.PFensibleM SLatent CFM Sensible Latent CFM I Sensible Zone 1 Dining, Media, Powder, Li 1 5371 11,1371 1,800 5371 11,1371 1,800 3811 11,740 PAGE TOTAL TOTAL* 537 11,137 1,800 381 11,740 537 11,137 1,800 381 11,740 * Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnergySoft User Number.' 3665 RunCode: 2014-10-03714:02:35 /D: Page 34 of 59 ROOM LOAD SUMMARY Lot 15-8 Residence 10/3/2014 HVAC 2 1,380 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM I Sensible I Latent I CFM I Sensible Zone 2 Great Room, Kitchen, Pad 1 1,0141 20,5731 1,886 1,0141 20,5731 1,8861 7081 21,551 PAGE TOTAL TOTAL ' ' Total includes ventilation load for zonal 1,014 20,573 1,886 708 21,551 1,014 20,573 1,886 708 21,551 ROOM LOAD SUMMARY Lot 15-8 Residence 10/3/2014 System Name Floor Area HVAC 3 599 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room NameMult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 3 Entry, Office 1 780 1 15,526 1 818 7801 15,5261 818 3851 11,802 ' Total includes ventilation load for zonal PAGE TOTAL TOTAL' 780 15,526 818 385 11,802 780 15,526 818 385 11,802 2014-10-03T14:02:35 /D: I ROOM LOAD SUMMARY I Project Name Date Lot 15-8 Residence 10/3/2014 System Name Floor Area HVAC 4 1,369 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name I Room Name Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM Sensible Zone 4 1 Master Suite 1 1 8341 17,0591 1, 871 8341 17,0591 1,871 5741 17,572 PAGE TOTAL TOTAL' 834 17,059 1,871 574 17,572 834 17,0591 1,8711 574 17,5721 Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03T14:02:35 /D: Page 37 of 59 ROOM LOAD SUMMARY Project Name Date Lot 15-8 Residence 10/3/2014 System Name Floor Area HVAC 5 1,005 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name I Mult. I CFM Sensible I Latent CFM Sensible Latent CFM I Sensible Zone 5 1 Guest BR 1, 2, GBa 1,2 1 1 1 7931 16,1731 1,373 793 16,1731 1,373 4801 14,896 PAGE TOTAL TOTAL* 793 16,173 1,373 480 14,896 793 16,173 1,373 480 14,896 * Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnergySoft User Number. 3665 RunCode: 2014-10-03714:02:35 ID: Page 38 of 59 ROOM LOAD SUMMARY Project Name Date Lot 15-8 Residence 10/3/2014 System Name Floor Area HVAC 6 2,053 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name I Mult.P1,3271 FM Sensible Latent CFM Sensible Latent CFM Sensible ZONE 6 Guest Suite 126,5421 2,805 1,3271 26,5421 2,805 6831 20,830 PAGE TOTAL TOTAL* 1,3271 26,5421 2,8051 683 20, 830 1,327 26,542 2,805 683 20,830 * Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03714:02:35 ID: Page 39 of 59 ROOM LOAD SUMMARY Project Name Date Lot 15-8 Residence 10/3/2014 System Name Floor Area HVAC 7 1,199 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name I Mult.CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 7 Conditioned Storage 1 5581 11,7891 1,638 5581 11,7891 1,638 4891 15,367 PAGE TOTAL TOTAL' I ' Total includes ventilation load for zonal 558 11,7891 1,6381 489 15,367 558 11,7891 1,6381 489 15,367 ROOM HEATING PEAK LOADS Project Name Lot 15-8 Residence Date 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining, Media, Powder, Laundry, Hall Floor Area 1,317.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value 0.0690 X 0.3900 X 0.0690 X 0.5400 X 0.0250 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X another room 10.00 X 0.323 Height ACH AT °F Btu/hr 42 = 2,637 42 = 737 0 c 0 42 _ 1,814 42 c 618 42 = 2, 744 = = = = = = = = = = = = = = Page Total 8,551 /60] X 42 = 3,188 AT R-21 Wall 910.0 Dual Pane Tinted, Metal, Fixed 45.0 'R-21 Wall 720.0 Dual Pane Tinted, Metal, Sliding 80.0 R-38 Roof Attic 589.0 Slab-On-Grade perim = 89.5 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 1,317 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 11,740 EnergyPro 6.3 by EnergySoft User Number: 3665 Runcode: 2014-10.03714:02:35 ID: Page 41 of 59 ROOM HEATING PEAK LOADS Project Name Lot 15-8 Residence Date 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room, Kitchen, Pantry, Bar Floor Area 1,380.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value 0.0690 X AT °F 42 _ 42 = 0 = 42 = Btu/hr R-21 Wall 671.5 1,946 Dual Pane Tinted, Metal, Fixed 173.0 0.3900 X X X 2,834 'R-21 Wall 620.0 0.0690 0 Dual Pane Tinted, Metal, Sliding 375.5 0.5400 8,516 R-38 Roof Attic 1,380.0 0.0250 X 42 c 1,449 Slab-On-Grade perim = 113.0 0.7300 X 42 = 3,465 X = X X = = X X X = = = X = X = X X X = = = X = X X = = = X X = X X X = = = X = X X X = = = X I= = X I d Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 1,380 X Area another room 10.00 X 0.323 Height ACH Page Total /60] X 42 AT 18,210 = 3,341 TOTAL HOURLY HEAT LOSS FOR ROOM 21,551 EnergyPro 6.3 by EnergySoft User Number: 3665 Run Code: 2014-10-03714:02:35 ID: Page 42 of 59 ROOM HEATING PEAK LOADS Project Name Lot 15-8 Residence Date 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Entry, Office Floor Area 599.0 ft2 Indoor Dry Bulb Temperature 68 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F _ = c c = c 0 c = = = = = = = = = 42 Btu/hr "R-21 Wall 426.0 0.0690 0 0 R-21 Wall 237.0 0.0690 42 687 Dual Pane Tinted, Metal, Fixed 78.0 0.3900 42 1,278 Single 1 " Pane Glass Door 53.0 1.2800 42 2,849 Dual Pane Tinted, Metal, Sliding 125.0 0.5400 42 2,835 Dual Metal Tinted Casement 23.0 0.5600 42 541 R-38 Roof Attic 599.0 0.0250 42 629 Slab -On -Grade perim = 50.0 0.7300 42 1,533 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 599 X Area another room 10.00 X 0.323 Height ACH Page Total /60] X AT 10,352 _ 1,450 TOTAL HOURLY HEAT LOSS FOR ROOM 11,802 EnergyPro 6.3 by EnergySoft User Number.' 3665 RunCode: 2014-10-03714:02:35 ID: Page 43 of 59 ROOM HEATING PEAK LOADS Project Name Lot 15-8 Residence Date 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,369.0 ft2 Indoor Dry Bulb Temperature 68 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT of Btu/hr X 42 = 3,341 X 0 = 0 X 42 c 4,308 X 42 c 2,359 X 42 = 1,424 X 42 = 35 X 42 = 2,790 X = X X = X = X X X = X = X X X X X X = X X = X = X = X = X = X = X X X = Page Total 14,257 /60] X 42 0 3,314 AT R-21 Wall 1,153.0 X X 0.0690 'R-21 Wall 390.0 0.0690 Dual Pane Tinted, Metal, Fixed 263.0 X X 0.3900 Dual Pane Tinted, Metal, Sliding 104.0 0.5400 R-38 Roof Attic 1,356.2 X X 0.0250 So/atube 290 Dse 2.8 0.3000 Slab -On -Grade perim = 91.0 X X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X to another room 10.00 X 0.323 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 1,369 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 17,572 EnergyPro 6.3 by EnergySoft User Number.' 3665 RunCode: 2014-10-03714:02:35 /D: Page 44 of 59 ROOM HEATING PEAK LOADS Project Name Lot 15-B Residence Date 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest BR 1, 2, GBa 1,2 Floor Area 1,005.0 ftZ Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr c 2,828 = 3,423 = 2,140 c 716 = 0 c 1,055 = 2,300 = = = = = = = = = = = 12,463 42 = 2,433 R-21 Wall 976.0 X 0.0690 42 Dual Pane Tinted, Metal, Fixed 209.0 X 0.3900 42 Dual Metal Tinted Casement 91.0 X X 0.5600 42 Double Metal Clear 24.0 0.7100 42 'R-21 Wall 210.0 X X 0.0690 0 R-38 Roof Attic 1,005.0 0.0250 42 Slab-On-Grade perim = 75.0 X 0.7300 42 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 1,005 X Area to another room 10.00 X 0.323 Ceiling Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 14,896 EnergyPro 6.3 by EnergySoft User Number.' 3665 RunCode: 2014-10-03714:02:35 ID: Page 45 of 59 ROOM HEATING PEAK LOADS Project Name Lot 15-8 Residence 710/3/2014 Date ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Floor Area 2,053.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT *F Btu/hr = 4,310 = 4,757 = 1,270 = 3,368 c 2,156 0 0 = = = = = = = = = = = = = = = = = 15,860 42 = 4,970 R-21 Wall 1,487.1 X X X X 0.0690 X X X 42 Dual Pane Tinted, Metal, Fixed 290.4 0.3900 42 Dual Metal Tinted Casement 54.0 0.5600 42 Dual Pane Tinted, Metal, Sliding 148.5 0.5400 X 42 R-38 Roof Attic Z053.0 _X X 0.0250 X 42 'R-30 Floor No Crawlspace 2,053.0 0.0390 X 0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 8.00 X 0.403 Ceiling Height ACH X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 2,053 X Area Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 20,830 EnergyPro 6.3 by EnergySott User Number: 3665 RunCode: 2014-10-03T14:02:35 ID: Page 46 of 59 ROOM HEATING PEAK LOADS Project Name Lot 15-8 Residence Date 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Conditioned Storage Floor Area 1,199.0 ftZ Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value AT *F 0.0690 X 42 0.5000 X 42 0.0690 X 0 0.7300 X 42 X X X X X X X X X X X X X X X X X X X X X X X X X X X another room Page Total 8.00 X 0.403 /60] X Height ACH AT Btu/hr = 2,968 = 6,216 = 0 = 3,281 = = = = = = = = = = = = = 12.464 42 = 2,903 R-21 Wall 1,024.0 Wood Door 296.0 'R-21 Wall 1,449.0 Slab-On-Grade perim = 107.0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 1,199 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 15,367 EnergyPro 6.3 by EnergySoft User Number. 3665 RunCode: 2014-10-03714:02:35 ID: Page 47 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining, Media, Powder, Laundry, Hall Outdoor Dry Bulb Temperature 112 OF Floor Area 1,317.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (NIM 730.0 X 0.0690 X 30.2 = 1,523 `R-21 Wall 720.0 X 0.0690 X 0.0 = 0 R-21 Wall (SIM 40.0 X 0.0690 X 31.0 = 86 R-21 Wall (SE) 140.0 X 0.0690 X 31.0 = 299 R-38 Roof Attic (N) 589.0 X 0.0250 X 56.0 = 825 X X = X X = X X = X X = Page Total 2.732 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 08 (NIM 0.0 X 16.7 + 25.0 X 24.4 = 611 Window 09 (SIM 20.0 X 16.7 + 0.0 X 22.1 = 334 Window El (SIM 80.0 X 19.7 + 0.0 X 25.1 = 1,576 X + X - X + X - X + X - X + X - X + X - X +1 X - Page Total 21521 Internal Gain Btu/hr Occupants 4.0 Occupants X 245 Btuh/occ. = E968 Equipment 1,317 Floor Area X 0.50 w/sgft = 2,247 Infiltration: 1.072 X 1.20 X 55.96 X 37 = 2,668 Air Sensible CFM ELA AT [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,137 Latent Gain Btu/hr Occupants 4 0 Occupants X 155 Btuh/occ. = 612 Infiltration: 4,806 X 1.20 X 55.96 X 0.00367 = 1,187 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 612 EnergyPro 6.3 by EnerqySoft User Number- 3665 RunCode: 2014-10-03714:02:35 /D: Pa a 48 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room, Kitchen, Pantry, Bar Outdoor Dry Bulb Temperature 112 OF Floor Area 1,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranqe: 34 OF Surfaces R-21 Wall 'R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic Orientation (N►M (SM (SE) (NE) (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 23.0 0.0690 30.2 620.0 0.0690 0.0 124.0 0.0690 31.0 151.5 0.0690 31.0 373.0 0.0690 29.0 1,380.0 0.0250 56.0 10.0 16.7 0.0 22.1 218.0 19.7 0.0 25.1 12.0 16.7 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 10 Window 11 Window 12 Window 13 Window 14 Window S-1 Window 15 Window 16 Window 17 Orientation (NW) (SVtq (SVtq (SW) (SVV) (SW) (SE) (SE) (SE) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF - = = - = _ _ - - 0.0 16.7 27.0 24.4 10.0 16.7 0.0 22.1 9.0 16.7 0.0 22.1 9.0 16.7 0.0 22.1 10.0 16.7 0.0 22.1 218.0 19.7 0.0 25.1 12.0 16.7 0.0 22.1 9.0 16.7 0.0 22.1 10.0 1 16.7 0.0 1 22.1 Page Total Btu/hr 48 0 265 324 746 1,932 3,316 Btu/hr 659 167 150 150 167 4,296 200 150 167 6,108 Internal Gain Btu/hr Occupants 41 Occupants X 245 Btuh/occ. 1'1 Equipment 1,380 Floor Area X 0.50 w/sgft = 2,; Infiltration: 1.072 X 1.20 X 58.63 X Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,5731 Latent Gain Btu/hr Occupants 41 Occupants X 155 Btuh/occ. = 642 Infiltration: 4,806 X 1.20 X 58.63 X 0.00367 = 1,244 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6421 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-8 Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room, Kitchen, Pantry, Bar Outdoor Dry Bulb Temperature 112 OF Floor Area 1,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window F2 (SE) 157.5 X 19.7 + 0.0 X 25.1 = 3,104 Window 04 (NE) 0.0 X 16.7 + 21.0 X 24.4 = 513 Window 05 (NE) 0.0 X 16.7 + 21.0 X 24.4 = 513 Window 06 (NE) 0.0 X 16.7 + 35.0 X 24.4 = 855 X + X = X + X = X + X = X + X = X + X = Page Total 4.98 Internal Gain Btu/hr Occupants 4.1 Occupants X 245 Btuh/occ. = 1,014 Equipment 1,380 Floor Area X 0.50 w/sgft = 2,355 Infiltration: 1.072 X 1.20 X 58.63 X 37 = 2,796 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,573 Latent Gain Btu/hr Occupants 4.1 Occupants X 155 Btuh/occ. = 642 Infiltration: 4,806 X 1.20 X 58.63 X 0.00367 = 1,244 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 642 EnergyPro 6.3 by EnerqySoft User Number., 3665 RunCode: 2014.10-03T14:02:35 ID: Page 50 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Entry, Office Outdoor Dry Bulb Temperature 112 OF Floor Area 599.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Dally Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr 'R-21 Wall 426.0 X 0.0690 X 0.0 = 0 R-21 Wall (NE) 28.0 X 0.0690 X 34.0 = 66 R-21 Wall (Sim 140.0 X 0.0690 X 52.0 = 502 R-21 Wall (NK) 69.0 X 0.0690 X 48.1 = 229 R-38 Roof Attic (N) 599.0 X 0.0250 X 77.0 = 1,153 X X = X X = X X = X X = Page Total 1,950 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 02 (NE) 0.0 X 19.7 + 30.0 X 28.6 = 857 Window 03 (NE) 0.0 X 19.7 + 15.0 X 28.6 = 429 Window 81 (NE) 0.0 X 63.6 + 53.0 X 92.2 = 4,886 Window G 1 (s V109 125.0 X 22.7 + 0.0 X 53.5 = 2,834 Window 18 (SVV) 25.0 X 19.7 + 0.0 X 50.5 = 492 Window 56 (NVt,) 0.0 X 23.6 + 23.0 X 46.5 = 1,068 Window 57 (NVIoq 0.0 X 19.7 + 8.0 X 41.6 = 333 X + X - X +1 X - Page Total 1o,soo Internal Gain Btu/hr Occupants 1.8 Occupants X 245 Btuh/occ. = d440E ui ment 599 Floor Area X 0.50 w/sgft = 1, Infiltration: 1.072 X 1.20 X 25.45 X 37 = 1,214 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,526 Latent Gain Btu/hr Occupants 1.8 Occupants X 155 Btuh/occ. = 279 Infiltration: 4,806 X 1.20 X 25.45 X 0.00367 = 540 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 279 EnergyPro 6.3 by Ene Soft User Number.- 3665 Run Code: 201410-03T14:02:35 ID: Page 51 of 59 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestratinn Window 20 Window 21 Window 22 Window 23 Window 24 Window 25 Window 26 Window 27 Window 28 Orientation (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + RESIDENTIAL ROOM COOLING LOAD SUMMARY X X X X X X X X X GLF = = = _ = _ - = = Project Name 16.7 0.0 22.1 Date Lot 15-B Residence 0.0 22.1 1 10/3/2014 ROOM INFORMATION 22.1 DESIGN CONDITIONS 16.7 0.0 22.1 Room Name Master Suite Outdoor Dry Bulb Temperature 22.1 112 OF Floor Area 1,369.0 ft2 Outdoor Wet Bulb Temperature 26.0 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range.- 16.7 0.0 34 OF 11.0 16.7 0.01 22.1 Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (NVtq 510.0 X 0.0690 X 30.2 = 1,064 "R-21 Wall 390.0 X 0.0690 X 0.0 = 0 R-21 Wall (SE) 533.0 X 0.0690 X 31.0 = 1,140 R-21 Wall (SK9 110.0 X 0.0690 X 31.0 = 235 R-38 Roof Attic (N) 1,356.2 X 0.0250 X 56.0 = 1,899 X X = X X = X X = X X = Page Total 4,338 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestratinn Window 20 Window 21 Window 22 Window 23 Window 24 Window 25 Window 26 Window 27 Window 28 Orientation (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = _ = _ - = = 9.0 16.7 0.0 22.1 12.0 16.7 0.0 22.1 9.0 16.7 0.0 22.1 27.5 16.7 0.0 22.1 11.0 16.7 0.0 22.1 104.0 16.7 0.0 22.1 26.0 16.7 0.0 22.1 27.5 16.7 0.0 22.1 11.0 16.7 0.01 22.1 Page Total Btu/hr 150 200 150 459 184 1,737 434 459 184 Internal Gain Btu/hr Occupants 41 Occupants X 245 Btuh/occ. = 1.1 Equipment 1,369 Floor Area X 0-W w/sgft = 2,; Infiltration: 1.072 X 1.20 X 58.17 X 37 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,0591 Latent Gain Btu/hr Occupants 41 Occupants X 155 Btuh/occ. = 637 Infiltration: 4,806 X 1.20 X 58.17 X 0.00367 = 1,234 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6371 52 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,369.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Dally Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window H1 (SW) 104.0 X 19.7 + 0.0 X 25.1 = 2,049 Window 19 (SI/10 26.0 X 16.7 + 0.0 X 22.1 = 434 Skylight SOS -47 (N) 0.0 X 17.5 + 1.4 X 58.1 = 81 Skylight S06-48 (N) 0.0 X 17.5 + 1.4 X 58.1 = 81 X + X = X + X = X + X = X + X = X +1 X — Page Total 2.64 Internal Gain Btu/hr Occupants 41 Occupants X 245 Btuh/occ. = L:::1,006 Equipment 1,369 Floor Area X 0.50 w/sqft = 2,336 Infiltration: 1.072 X 1.20 X 58.17 X 37 = 2,773 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,059 Latent Gain Btu/hr Occupants 4.1 Occupants X 155 Btuh/occ. c 637 Infiltration: 4,806 X 1.20 X 58.17 X 0.00367 = 1,234 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 637 EnergyPro 6.3 by EnerqySoft User Number: 3665 RunCode: 2014-10-03714:02:35 ID: Page 53 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest BR 1, 2, GBa 1,2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,005.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces R-21 Wall R-21 Wall R-21 Wall R-21 Wall "R-21 Wall R-38 Roof Attic Orientation (NE) (NtM (SE) (SW) (N) Area X X X X X X X X X U -Factor X X X X X X X X I X CLTD' = = = = = = = = 299.0 0.0690 29.0 273.0 0.0690 30.2 328.0 0.0690 31.0 76.0 0.0690 31.0 210.0 0.0690 0.0 1,005.0 0.0250 56.0 0.0X 16.7+ 10.0X 24.4= 0.0 41.3 24.0 64.8 I= 16.7 8.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 32 Window 36 Window 37 Window 38 Window 39 Window 40 Window 41 Window 42 Window 43 Orientation (NE) (NE) (NE) (NE) (NE) (NKK (NIM (NW) (NW) Shaded Unshaded Btu/hr 1 5691 Area X X X X X GLF + + + + + Area X X X X X GLF = - _ _ - 0.0X 16.7+ 10.0X 24.4= 0.0X 16.7+ 5.0X 24.4= 0.0 16.7 16.0 24.4 0.0 20.5 30.0 28.5 0.0X 16.7+ 10.0X 24.4= 0.0 41.3 24.0 64.8 0.0 16.7 8.0 24.4 0.0X 20.5+ 23.0X 28.5= 0.0 16.7 8.0 24.4 Page Total 1, Btu/hr 244 122 391 856 244 1,554 195 656 19 4,4581 Internal Gain Btu/hr Occupants 3 0 Occupants X 245 Btuh/occ. _ Equipment 1,005 Floor Area X 0.50 w/sqn Infiltration: 1.072 X 1.20 X 42.70 X 37 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,1731 Latent Gain Btu/hr Occupants 3 0 Occupants X 155 Btuh/occ. = 467 Infiltration: 4,806 X 1.20 X 42.70 X 0.00367 = 906 Air Sensible CFM ELA OW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4671 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot 15-8 Residence 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest BR 1,2, GBa 112 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,005.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF ue Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = = = = c = - = = 0.0 X X X 16.7 38.0 24.4 0.0X 16.7+ 16.0X 24.4= 15.0 20.5 0.0 26.1 18.0 16.7 0.0 22.1 5.0 X X 16.7 0.0 22.1 5.0 16.7 0.0 22.1 2.0 X X Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 48 Window 49 Window 29 Window 30 Window 31 Window 33 Window 34 Window 35 Window 44 Orientation (NM (NM (SE) (SE) (SE) (SE) (SE) (SE) (SVO Shaded Area GLF + + + + + + + +1 Unshaded Area X X X X X X X X1 GLF = = = c = - = = 0.0 X X X 16.7 38.0 24.4 0.0X 16.7+ 16.0X 24.4= 15.0 20.5 0.0 26.1 18.0 16.7 0.0 22.1 5.0 X X 16.7 0.0 22.1 5.0 16.7 0.0 22.1 2.0 X X 16.7 0.0 22.1 7.0 16.7 0.0 22.1 22.8 X1 20.5 0.2 26.1 Page Total Btu/hr Btu/hr 928 391 307 301 84 84 33 117 472 2, 71 Internal Gain Btu/hr Occupants 3.0 Occupants X 245 Btuh/occ. = 739 Equipment 1,005 Floor Area X 0.50 w/sgft = 1,715 Infiltration: 1.072 X 1.20 X 42.70 X 37 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,173 Latent Gain Btu/hr Occupants 3 0 Occupants X 155 Btuh/occ. = 467 Infiltration: 4,806 X 1.20 X 42.70 X 0.00367 = 906 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4671 IEnergyPro 6.3 by EnergySoft User Number: 3665 RunCode: 2014-10-03714:02:35 ID: Page 55 of 591 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest BR 1, 2, GBa 1,2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,005.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF, Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 45 (SM 8.0 X 16.7 + 0.0 X 22.1 = 134 Mindow 46 (St" 27.6 X 16.7 + 9.4 X 22.1 = 669 Window 47 (S K9 16.0 X 16.7 + 0.0 X 22.1 = 267 X + X — X + X — X + X — X + X = X + X — X +1 XI — Page Total 1,070 Internal Gain Btu/hr Occupants 3 0 Occupants X 245 Btuh/occ.=L 739 Equipment 1,005 Floor Area X 0.50 w/sqft = 1,715 Infiltration: 1.072 X 1.20 X 42.70 X 37 = 2,036 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,173 Latent Gain Btu/hr Occupants 3.0 Occupants X 155 Btuh/occ. = 467 Infiltration: 4,806 X 1.20 X 42.70 X 0.00367 = 906 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 467 EnergyPro 6.3 by EnergySoft User Number. 3665 RunCode: 2014-10-03714:02:35 ID: Pae 56 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot 15-8 Residence 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 2,053.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic 'R-30 Floor No Crawlspace Orientation (NE) (NVt9 (SE) (SVL9 (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = Btu/hr 233.5 0.0690 29.0 467 469.0 0.0690 30.2 978 355.0 0.0690 31.0 759 429.6 0.0690 31.0 919 2,053.0 0.0250 56.0 2,874 2,053.0 0.0390 0.0 0 7.0 24.4 171 0.0 16.7 12.0 24.4 293 81.5 16.7 I= 22.1 2,280 11.0 Page Total 5,998 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration VVindow 65 Krindow 66 Window P1 VVindow 67 Krindow 68 Window 69 Window 58 Kfindow 63 Window 64 I Internal Gain Orientation (NE) (NE) (NE) (NVtq (NVtg (NAA (SE) (SE) (SE) Area X X X X X X X X GLF + + + + + + + + Area X X X X X X X X GLF - = = = _ - - - Btu/hr 0.0 16.7 54.0 24.4 1,319 0.0 20.5 54.0 28.5 1,540 0.0 19.7 148.5 27.4 4,072 0.0X 16.7+ 12.0X 24.4- 293 0.0 16.7 7.0 24.4 171 0.0 16.7 12.0 24.4 293 81.5 16.7 41.5 22.1 2,280 11.0 16.7 0.0 22.1 184 11.0 16.7 0.0 22.1 184 Page Total 10,33 6.2 Occupants X 245 Btuh/occ. 1 2,053 Floor Area X 0•mw/sgft = 3 Infiltration: 1.072 X 1.20 X 87.23 X 37 c Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26,5421 Latent Gain Btu/hr Occupants 6 2 Occupants X 155 Btuh/OCC. = 955 Infiltration: 4,806 X 1.20 X 87.23 X 0.00367 = 1,851 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 9551 I EnergyPro 6.3 by Ener_gySoft User Number- 3665 RunCode: 2014-10-03714:02:35 ID: Page 57 of 591 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-8 Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 2,053.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X X X = X X = X X = X X = X X X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 59 (S K9 23.4 X 16.7 + 5.1 X 22.1 — 504 Window 60 (SM 7.8 X 16.7 + 0.0 X 22.1 = 130 Window 61 (StM 12.8 X 16.7 + 0.0 X 22.1 = 214 Window 62 (SIAL 7.0 X 16.7 + 0.0 X 22.1 _ 117 Window 73 (SIA9 4.3 X 16.7 + 0.0 X 22.1 = 72 X + X — X + X — X + X — X +1 X — Page Total 1,03 Internal Gain Btu/hr Occupants 6 2 Occupants X 245 Btuh/occ. = 1,509 Equipment 2,053 Floor Area X 0.50 w/sq(t o 3,503 Infiltration: 1.072 X 1.20 X 87.23 X 37 = 4,159 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26,542 Latent Gain Btu/hr Occupants 6 2 Occupants X 155 Btuh/occ. = 955 Infiltration: 4,806 X 1.20 X 87.23 X 0.00367 = 1,851 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 955 EnergyPro 6.3 by EnergySoft User Number. 3665 RunCode: 2014-10-03714:02:35 /D: Pae 58 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 15-B Residence 1 10/3/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Conditioned Storage Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 199.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (NE) 264.0 X 0.0690 X 29.0 = 528 Wood Door (NE) 296.0 X 0.5000 X 29.0 = 4,292 R-21 Wall (NW) 250.0 X 0.0690 X 30.2 = 521 R-21 Wall (SE) 250.0 X 0.0690 X 31.0 = 535 R-21 Wall (SW) 260.0 X 0.0690 X 31.0 = 556 'R-21 Wall 1,449.0 X 0.0690 X 0.0 = 0 X X = X X = X X = Page Total 6,433 Items shown with an asterisk denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr X + X - X + X - X + X - X + X - X + X = X + X - X + X - X + X - X + X - Page Total 0 Internal Gain Btu/hr Occupants 3.6 Occupants X 245 Btuh/occ. = 881 Equipment 1, 199 Floor Area X 0.50 w/spft = 2,046 Infiltration: 1.072 X 1.20 X 50.94 X 37 = 2,429 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,789 Latent Gain CITvT T CF i � L1tI� Btu/hr Occupants 36 Occupants X I 6UlW Btu /occSAFEI Y DL i -IT. I 558 PPROVED Infiltration: X 1.20 X 50.94 X o.003s = FOR CONSTRUCTION 1'081 Sensible Air Sensible CFM ELA DW DATE TOTAL HOURLY LATENT HEAT GAIN FOR ROOM By 558 EneMyPro 6.3 by EnergySoft User Number 3665 RunCode: 2014-10-03714:02:35 /D: Page 59 of 59