0212-180 (SFD) Title 24I TITLE 24 REPORT I Title 24 Report for: CASA SEDONA 77-255 Calle Colima La Quinta, Ca 92253 Project Designer: Lendel Ventures, Inc. DBA Lench Design Group P.O. BOX 450 LA QUI NTA, CA 92253-0450 760/564-1866 Report Prepared By: VERNA LENCH Lendel Ventures, Inc P.O. Box 450 La Quinta, CA 92253-0450 (760) 564-1866 Job Number: 3.1-1154 CITY OF LA QU pl TA BUILDING & SAFETY D APPRO FOR CONSMGM014 DAM ' 8Y CT Date: 1/28/03. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 3.1-1154 User Number: 5454 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 7 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 13 Room Heating Peak Loads 15 Room Cooling Peak Loads 17 EnergyPro 3.1 By Energysoft Job Number: 3.1-1154 User Number: 5454 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R CASA SEDONA 1/28/03 Project Title Date 77-255 Calle Colima La Quinta Project Address Building Permit # Lendel Ventures, Inc (760) 564-1866 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: x,545 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 2,545 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deq Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION Shading Devices Type Orientation Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-49 Roof (R.49.2X16.16) Wood 0.018 Exterior Roof Slab On Grade We 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF Shading Yes / No Yes / No Skylight 44.0 0.65 0.40 None ❑ X❑ ❑ X❑ Front (North) 48.0 0.74 0.37 Bug Screen ❑ X❑ ❑ X❑ Rear (South) 18.0 0.60 0.37 Bug Screen ❑ X❑ ❑ X❑ Rear (South) 48.0 0.74 0.37 Bug Screen ❑ X❑ ❑X❑ Right (West) 54.0 0.60 0.37 Bug Screen❑ X❑ ❑ ❑X Right (West) 144.0 0.74 0.37 Bug Screen ❑ X❑ ❑ X❑ Right (West) 22.5 0.61 0.39 Bug Screen ❑ X❑ ❑ X❑ Left (East) 60.0 0.61 0.39 Bug Screen❑ X❑ ❑ ❑X Front (North) 16.5 0.62 0.38 Bug Screen❑ X❑ ❑ ❑X Left (East) 33.3 0.62 0.38 Bug Screen ❑ X❑ ❑ X❑ Rear (South) 24.0 0.62 0.38 Bug Screen ❑ X❑ ❑X❑ Rear (South) 10.5 0.46 0.37 Bug Screen ❑ a ❑ a Run Initiation Time: 01/28/03 07:05:14 Run Code: 1043766314 Ener Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1154 Pa e:3 of 20 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R CASA SEDONA 1/28/03 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments rantral Furnars+, 80% AFUE Ducts in Attic 4.2 Setback HVAC System Central Fumace 80% AFUE Ducts en Attic 42 Sethack HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.1 SEER Split Air Conditioner 12 _0RFFR Ducts in Attic Ducts in Atter 42 42 Sethnrk Sethark HVAC System HVAC System WATER HEATING SYSTEMS Water Heater Water Heater Distribution Rated 1 # in Input Tank Cap. Energy Facts 1 External or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -50-224 Small Gas Standard 1- 43,000 Fin 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES. NO DUPLICATION PERMITTED I COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: VERNA LENCH Title/Firm: Lendel Ventures, Inc. DBA Lench Design Group Title/Firm: Lendel Ve6tures, Inc Address: P O. BOX 450 Address: P.O. Box 450 QUINTA CA 92253- La Quinta, CA 92253-0450 Telepho 760/564-1866 Telephone: (760) 564-1866 Lic. #: 2 �• 03 ,� /- � Q3 ( ature) (date) (signature) (date) forcement Aqenc Name: Title/Firm: Address: Telephone: IEnergyPro 31 By EnergySoft User Number: 5454 Job Number: 3.1-1154 PageA of 20 1 Certificate of Compliance: Residential (Addendum) CF -1 R CASA SEDONA 1/28/03 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agencv determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan Field The HVAC System "HVAC Svstem" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 678 sqft Covered Slab Floor, 3.50" thick at ZONE 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 652 sqft Exposed Slab Floor, 3.50" thick at ZONE 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1011 sqft Exposed Slab Floor, 3.50" thick at ZONE 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 204 sqft Exposed Slab Floor, 3.50" thick at ZONE 2 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergvPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:5 of 20 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures F'§ 150(.): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. § 150(b): Loose fill insulation manufacturer's labeled R -Value. +§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ '§ 150(d): Minimum R-13 raised floor insulation in framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X] §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. X] §150(i): Setback thermostat on all applicable heating and/or cooling systems. X❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. X❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampe s. X] §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures X❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:6 of 20 Computer Method Summary (Part 1 of 3) C -2R 1CASA SEDONA Project Title 1198103 Date 77-255 Calle Colima laQijnnta Project Address Building Permit # I endel Ventures, Inr_ (760) 564-1866 Documentation Author Telephone plan Check/Date Comp It _r P _rfArrnanre Compl ante Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.38 3.56 -0.18 Space Cooling 36.67 35.86 0.80 Domestic Hot Water 11.20 9.86 1.34 Totals 51.24 49.28 1.96 GENERAL INFORMATION Conditioned Floor Area: 2,545 Floor Construction Type: X❑ Slab Floor Building Type: Single Farn Detached ❑ Raised Floor Building Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 25,450 Number of Stories: 1 Slab Floor Area: 2,545 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC system 1 330 13 inn S2_ Cnnditinned Setback_ n/a HVAC System '1,215 12,150 0.48 Conditioned Sethack —2 n/a OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Rnnf 1,294 _ (1 MR a _0 wall 122 �0-059 _a Aii Wall 20 n 05A Aa An Wall 31 0.059 0 go Dnnr 24 0.387 a 90 nnnr 20 0387 Cl An Wall 106 �apgg 270 90 nonr 24 0.367 270 90 Wall 245 0 ORR _�_ Aa Wall 109 _ 0"059 180 AQ Wall 126 n 059 270 90 Wall 20 n.059 0 90 Wall 16o n o59 270 _go Roof 1207 0.016 n rl Wall 193 n nsg 90 Aa Wall 32 — a 056_ —a 90 Wall 120 a ass Aa go Wall 18 _ n_059 0 ga wall 33 _ 0.059 90 90 Wall 18 _ 0"059 180 90 Wall 37 _ 0"059 _90 90 Wall 349 n.054 18n go Wall 104 — 0 055 270 90 Solar Gains Y / N Form 3 Reference Location / Comments I EnergvPro 3.1 9v EneravSoft User Number: 5454 Job Number: 3.1-1154 Page:7 of 20 1 Computer Method Summary (Part 2 of 3) C -2R CASA SEDONA 1/28/03 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments -I- Skylight Front firth) 4_0 n_650 0 40 None 0 Skylight "D FA I T VA )F-" ZONE 1 2 Skylight Front (North) 4.0 0.650 0.40 0 0 Skylight "DEFAULT VALUE" ZONE 1 3 Skylight Front (North) 4.0 0.650 0.40 0 0 Skylight "DEFAULT VALUE" ZONE 1 4 Skylight Front (North) 4.0 0.650 0.40 0 0 Skylight "DEFAULT VALUE" ZONE 1 5 Skylight Front (North) 4.0 0.650 0.40 0 0 Skylight "DEFAULT VALUE" ZONE 1 6 Skylight Front (North) 16.0 0.650 0.40 0 0 . k light "DEFAULT VALUE" ZONE 1 Z Window Front (North) 48.0 0,740 0.37 0 -9.0 Summit 5500 Al DP Low E ZONE 1 8 Window Rear (South) 18.0 0.600 0.37 180 90 Summit 5500 AI DP Low E ZONE 1 6 Window Rear (South) 48.0 0.740 0.37 180 _90 Summit 5500 Al DP Low E ZONE 1 1Q Window Right omestj 18.0 0.600 0.37 270 _90 Summit 5500 Al DP Low E ZONE 1 " Window Right (West) 48.0 0.740 0.37 270 90 Summit 5500 Al DP Low E ZONE 1 12 Window Right (West) 18.0 0.600 0.37 270 90 Summit 5500 Al DP Low E ZONE 1 Aa Window Right est) 22.5 0.610 0.39 270 _90 Summit 5500 Al DP Low E ZONE 1 14 Window Right (West) 48.0 0.740 0.37 270 90 Summit 5500 Al DP Low E ZONE 1 15 dight Front (North) 4.0 0.650 0.40 0 0 Skylight "DEFAULT VALUE" ZONE 2 16 Skylight Front (North) 4.0 0.650 0.40 0 0 Slylight "DEFAULT VALUE" ZONE 2 17 Window Left (East) 30.0 0.610 0.39 90 90 Summit 5500 AI DP Low E ZONE 2 18 Window Left (East) 30.0 0.610 0.39 90 90 Summit 5500 Al DP Low E ZONE 2 J,Q Window Front (North) 16.5 0.620 0.38 0 -9.0 Glass Block ZONE 2 20 Window Left (East) 33.3 0.620 0.38 90 90 Glass Block ZONE 2 21 Window Rear (South) 16.5 0.620 0.38 180 90 Glass Block ZONE 2 22 Window Rear (South) 4.5 0.460 0.37 180 90 Summit 5500 Al DP Low E ZONE 2 23 Window Rear (South) 7.5 0.620 0.38 180 90 Glass Block ZONE 2 24 Window Rear (South) 6.0 0.460 0.37 180 90 Summit 5500 Al DP Low E ZONE 2 25 Window Right (West) 18.0 0.600 0.37 270 90 Summit 5500 Al DP Low E ZONE 2 26 Window Right (West) 48.0 0.740 0.37 270 90 Summit 5500 AI DP Low E ZONE 2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 _2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 None 1.00 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 None 1.00 16 None 1.00 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Buq Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:8 of 20 1 Computer Method Summary Insulation (Part 3 of 3) C -2R R -Val. Depth Location / Comments Slab Perimeter 38 0.76 --Q 0 ZONE 1 CASA SEDONA —D Q 0 ZONE 1 1/28/03 Project Title HVAC System Date THERMAL MASS FOR HIGH MASS DESIGN HVAC System Hydronic Piping Pipe Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight 678 3M _28 0 98. n/a _2 ZCNF 1 / Slab on Grade Concrete. Heavyweight 652 3.50 28 0_98 n/a 0 ZONE 1 / Slab on Grade Concrete Heayyweight 1.01 3.50 _2$ A).9$ n/a _ 0 ZONE 2 / Slab on Grade Concrete, Heavyweight 204 3_50 28 0_98 n/a 0 ZONE 2 / Slab on Grade 12.0 SEER Ducts in Attic 4.2 Setback PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 38 0.76 --Q 0 ZONE 1 Slab Perimeter 99 0.76 —D Q 0 ZONE 1 Slab Perimeter 112 0.76 0.0 0 ZONE 2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System Central Furnace 805 AFUE Ducts in Attic 4.2 Setback HVAC System Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.1 SEER Ducts in Attic 4.2 Setback HVAC System Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Standard 1 43 000 50 0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Computer Method Summary (Addendum) C -2R CASA SEDONA 1/28/03 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the aaequacy or the special Jusurication ana aocumentation suominea. � Plan I Field The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 678 sgft Covered Slab Floor, 3.50" thick at ZONE 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 652 sgft Exposed Slab Floor, 3.50" thick at ZONE 1 HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1011 sgft Exposed Slab Floor, 3.50" thick at ZONE 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 204 sgft Exposed Slab Floor, 3.50" thick at ZONE 2 HERS Required Verification These features must be confirmed and/or tested by'a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow.Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 01/28/03 07:05:14 Run Code: 1043766314 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page: 10 of 20 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CASA SEDONA 1/28/03 SYSTEM NAME FLOOR AREA HVAC System 1,330 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sqft) 48.1 Cooling System Output per System 41,000 Total Output (Btuh) 41,000 Total Output (Tons) 3.4 Total Output (Btuh/sqft) 30.8 Total Output (sgftfTon) 389.3 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sqft) 1.05 Airflow (cfm/Ton) 409.8 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM lSensibleFLatent 20,210 CFM I Sensible 1,405 20,930 0 450 20,210 0 1,046 1,010 0 0 0 0 0 0 0 0 0 1,046 1,010 23 023 0 YORK H4DH042S06 24,160 11,999 Total Adjusted System Output 24,160 11,999 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 64,000 64,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.3 of 69.3 of 112.20F O4 Supply Air Ducts Outside Air 0 cfm 111.5 °F Supply Fan Heating Coil 1400 cfm ROOMS 69.3 of 70.0 OF Return Air Ducts 111.0/77.6OF 74.7/64.2OF 74.7/64.2OF . 60.0/59.2OF Outside Air O 0 cfm Supply Fan 1400 cfm 74.7/64.2 of Cooling Coil h Return Air Ducts `i Supply Air Ducts 60.7 / 59.4 of 58.5% R.H. ROOMS 74.0/64.0 OF EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page: 11 of 20 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CASA SEDONA 1/28/03 SYSTEM NAME FLOOR AREA HVAC System 1,215 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKJ COIL HTG. PEAK CFM Sensible Latent CFM Sensible 522 16,477 565 366 14,372 0 824 719 0 0 0 0 0 0 0 0 0 824 719 18,1241 565 15 809 YORK H4DH036S06 28,630 0 35,000 Total Adjusted System Output 28,630 0 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.2 of 69.2 of 107.7 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 106.9 of 855 cfm ROOMS 70.0 of 69.2 of 11.0/77.6OF 78.9/59.1OF Outside Air O 0 cfm Supply Far 855 cfm 78.9/59.10F h Return Air Ducts `i 78.9 / 59.1 of 47.4 / 45.8 of Cooling Coil Supply Air Ducts 48.3/46.3OF 30.6% R.H. ROOMS 78.0 / 58.8 of I EnerovPro 3.1 By EnerovSoft User Number: 5454 Job Number: 3.1-1154 Paae:12 of 20 1 ROOM LOAD SUMMARY PROJECT NAME DATE CASA SEDONA 1/28/03 SYSTEM NAME FLOOR AREA HVAC System 1,330 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 1 ZONE 1 1 1,405 20,930 0 1,405 20,930 0 450 20,210 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:13 of 20 ROOM LOAD SUMMARY PROJECT NAME CASA SEDONA DATE 1/28/03 SYSTEM NAME HVAC System FLOOR AREA 1,215 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 2 ZONE 2 1 522 16,477 565 522 16,477 565 366 14,372 PAGE TOTAL 1 522 16,477 565 366 14,372 TOTAL 1 522 16,477 565 366 14,372 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page: 14 of 20 ROOM HEATING PEAK LOADS Project Title Date CASA SEDONA 11/28/03 Room Information Desicin Conditions Room Name ZONE 1 Time of Peak Jan 12 am Floor Area 1,330 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 1294.0 X x x X x x x x X X x X X X X X X X X X X X X X X X X X X X X X X X x X X X X 0.0184 x x x x x x x X x X x X X X X X X X X X X X X X X X X X x x X X X X X X X X X 44.0 = = = = = = = = = = = = = = = = 1,047 36.0 0.6500 44.0 1,030 perimeter = 129.5 44.5 5,763 607.5 0.0585 44.0 1,564 192.0 0.7400 44.0 6,252 68.0 0.3872 44.0 1,159 351.0 0.0885 44.0 1,367 54.0 0.6000 44.0 1,426 22.5 0,6100 44.0 604 Items shown with an asterisk (rr) denote conduction through an interior surface to another room. Page Total: I 20.2101 Infiltration: I1 1.001 x 1.064 x 1 330 x 10.00 x 0.00 / 60] x ® = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,210 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page: 15 of 20 ROOM HEATING PEAK LOADS Project Title Date CASA SEDONA 11/28/03 Room Information Desicin Conditions Room Name ZONE 2 Time of Peak Jan 12 am Floor Area 1,215 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 1207.0 x x X X X X x x X x x x x X X X x x X X X X X x x X X X x x x x x X x x X X X 0.0184 x X X x x x x x x X X x X X x x x x x x x x x x X X x X x X X x X x x x X X x 44.0 = = = = = = = = = = = = = = = = = 977 8.0 0.6500 44.0 229 perimeter = 111.5 44.5 4,962 905.1 0.0585 44.0 2,330 60.0 0.6100 44.0 1,610 73.8 0.6200 44.0 2,013 10.5 0.4600 44.0 213 18.0 0.6000 44.0 475 48.0 0,7400 44.0 1563 Items shown with an asterisk (r) denote conduction through an interior surface to another room. Page Total: 14 372 Infiltration: 1.001 x' 1.064 x 1 215 x 10.00 x 6] x ® = 0 chedule Alr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,372 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:16 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASASEDONA 1/28/03 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area X X X X X X X x X U -Value 1,2941 0.0184 36. 0.6500 607.1 0.0585 192A 0.7400 68A 0.3872 351.0 0.0885 54.0 0.6000 22, 0,6100 West ( 0.0 ZONE 1 740F 112°F 380E X X X X X X X DETD 1 = = = = = = = Btu/hr 55.0 1,309 38.0 889 34.6 1,230 38.0 5,399 34.6 911 34.6 1.075 38.0 1.231 X X 1. Design Equivalent Temperature Difference (DETD) Page Total 12,566 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight (Skylight) Skylight (Skylight) SkAiciht (Skylight) Skylight S li ht Skylight (Skylight) Skylight (Skylight) Window 6080 FR DR (North) Window 3060 SH (South) Window 6080 FR DR (South) Window 3060 SH West ( 0.0 x1 x x x x x x x X x + 1 + 1 + 1 • + 1 + 10+ 1 + 1 + 1 + 1 + 4.0 X X x x x x x x X X 152)X ) x X x x ) X x 0.460 = = = = = = = = _ = 280 ( 0.0 4.0 152 0.460 280 ( 0.0 4.0 152) 0.460 280 ( 0.0 4.0 152) 0.460 280 ( 0.0 4.0 152) 0.460 280 ( 0.0 16.0 152)X 0.460 1,118 ( 0.0 48.0 15)X 0.412 297 ( 0.0 18.0 32)X 0.412 237 ( 0.0 48.0 3 0.412 633 ( 0.0 18.0 73) 0.412 541 Sched. Page Total a 22 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,330 x 0.00 Watts/sgft x 3.413 Btuh/Watt = 0 Occupants 1.00 X 1,330 x Btuh/OCC. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 1.33 x 0.00 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,330 x 0.00 Watts/sgft x 3.413 BtuhMatt = 0 Infiltration: l dd Q01 x Air Sensible x Area x Ceiling x ACH / 60] �C, T _ �0 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,930 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 330 x 0 Btuh/occ. / 20 00 sgft/OCc. _ Receptacle 1.00 x 1 330 x 0.000 Watts/sgft x 3. 1 Btuh/Watt = 0 Process r 1.00 x 330 x 0.000 Watts/sgft x 3 1 BtuhlWatt = Infiltration: I 1.00 XE 4,77 X 1 33 x 10.00 x 0.00 / 60] 0.00000 = �0 --- chedule Air Latent Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page: 17 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASASEDONA 1/28/03 Project Title ..- Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X X X X X X X X DETD1 ZONE 1 74°F 112°F 380F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 3080 2 FR DR (West) 0.0 x 1 + 48.0 X —73)X 0.41 = 1,443 Wndnw 31716171 SH (West) ( 0.0 x 1 + 18.0 x 73) x 0.412 = 541 Window 5046 XO (West) ( 0.0 x 1 + 22.5 x 73) X 0.434 = 713 Window 3080 2 FR DR (West) ( 0.0 x 1 + 48.0 x 73) x 0.41 = 1,443 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total a 4 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,330 X 0.00 Watts/sgft x 3.413 BtuhlWaft = 0 Occupants 1.00 X 1.33 x Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 1,33 X 0.00 Watts/sgft x 3.413 BtuhMatt = 0 Process 1.00 x 1,33 x 0.00 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: �� x Air Sensible � x Area 1,33 x Coiling x ACH 00 / 60] � _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20930 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 30 x 01 Btuh/occ. / 20 00 sgft/occ. _ Receptacle 1.00 x 1 330 x 0.000 Watts/sgft X 4 Btuh/Waft = 0 Process 1.00 x 33 x 0.000 Wafts/sgft x 3.41 BtuhfWaft = 0 Infiltration: 1 d �ne.00 X Air Latent X X x 6 Area 33 Coiling Height ACH 00 / 0] 00`00000 = 0 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:18 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA SEDONA 1/28/03 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-49 Roof RAUX16.16 k li ht "DEFAULT VALUE" R-13 Wall w/1" EPS ummit 5500 Al DP Low E 31ass Bloc ummit 5500 Al DP Low E ummit 5500 Al DP Low E 3ummit 5500 Al DP Low E Area U -Value X DETD 1 51.0 34.0 30.6 34.0 34.0 34.0 34.0 34.0 ZONE 2 780E 1120F 340E Btu/hr 1,132 177 1,621 1,244 1,556 164 367 1. Design Equivalent Temperature Difference (DETD) Page Total 7 469 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight (Skylight) + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + (Skylight) Window 5060 XO Window 5060 XO (East) (East) Window 3056 GL BLK (North) Window 6056 GL BLK (East) Window 3056 GL BLK (South) Window 1016 3 FO (South) Window 2630 GL BLK (South) Window 1016 4 FO South ( 0.0 X1 X x x x x x x x x + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 4.0 X x x x x x X x X x 152 ) X x x x x ) X x 0.46 = = = = = = = = __ = 280 ( 0.0 4.0 152) 0.460 280 ( 0.0 30.0 73)X 0.434 951 ( 0.0 30.0 73) 0.434 951 ( 0.0 16.5 15) 0.423 105 ( 0.0 33.3 73)X 0.423 1,028 ( 0.0 16.5 32)X 0.423 223 ( 0.0 4.5 32) 0.41 59 ( 0.0 7.5 3 0.423 102 ( 0.0 6.0 32) 0.412 79 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,215 x 0.00 Watts/sgft x 3.413 Btuh/Waft = 0 Occupants 1.00 x 1.21 x 241 Btuhlocc. / 333 sgft/occ. = 893 Receptacle 1.00 x 1.21 x 0.50 Wafts/sgft x 3.413 Btuh/Waft = 2,073 Process 1.00 x 1,21 x 0.00 Wafts/sgft x 3.413 Btuh/Waft = 0 Infiltration: x Airs x L Area 1.215) x Ceiling x ACH / 60] � 01 _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,477 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 21 x 155 Btuh/occ. / 33 sgft/occ. _ Receptacle 1.00 x 1 215 x 0.000 Watts/sgft X 3.41 BtuhMatt = 0 Process r 1.00 x 1 21 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: I 1.0o x 4,77 x 1 21 x 10.0o x o.00 / 60] o.00000 = �0 chedule Air Latent Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 565 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1154 Page: 19 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA SEDONA 1/28/03 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD 1 ZONE 2 78°F 112°F 340E Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 3060 SH (West) ( 0.0 x 1 + 18.0 x 73)X 0.412 = 541 Wonfinw AnAn FIR DR (West) ( 0.0 x 1 + 48.0 x 73)x 0.412 = 1,443 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total L9s Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,215 x 0.00 Watts/sgft x 3.413 Btuh/Waft = 0 Occupants 1.00 x 1,215 x 2411 Btuh/occ. / 333 sgft/occ. = 893 Receptacle 1.00 x 1.21 x 0.50 Wafts/sgft x 3.413 Btuh/Watt = 2,073 Process 1.00 x 1,215 x 0.00 Wafts/sgft x 3.413 Btuh/Watt = 0 Infiltration: 1.0o x � x 215 x U 0 x � / 60� chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16477 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 155 Btuh/occ. / 33 sgft/occ. _ Receptacle 1.00 x 1 215 x 0.000 Watts/sgft x Btuh/Watt = 0 Process 1.00 x 1 15 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: 1 1.00 x 4 77 tent Area Ceiling Heighx 1 21 x Height x ACH 60] 0.00000 = 0 chedule AIr LaDW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 565 Energ Pro 3.1 by EnergySoft User Number: 5454 Job Number: 3.1-1154 Page:20 of 20