Loading...
BRES2016-0199 Title 24I BUILDING ENERGY ANALYSIS REPORT PROJECT: Madison Custom Residence Lot 19B -Madison Club La Quinta, CA 92253 Project Designer: Hayer Architects 445 Marine View Ave., Suite 280 Del Mar, CA 92014 (858) 752-2800 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc, 74818 Velie Way Suite 8 Palm Desert, CA 92260 (760) 200-4780 OvTt Ck, CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: DAT5q4 JAPk 1b BY v� Date: 4/4/2018 RECEIVED APR 0 5 2018 CITY OF LA QUINTA COMMUNnY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. R14A 1 I TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance Form RMS-1 Residential Measures Summary Form MF-1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads CITY OFLAQUANTA BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION I DATE -_-BY I EnergyPro 7.2 by EnergySoft Job Number 11): User Number 6712 1 2 3 19 22 26 34 42 51 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence L aeuulation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - Poy- . of 16 GENERAL INFORMATION 01 Project Name Madison Custom Residence 02 Calculation Description Title 24 Analysis 03 Project Location Lot 19B - Madison Club 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 110 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 12597 15 Number of Zones 9 16 Slab Area (ftz) 12597 17 Number of Stories 1 18 Addition Cond. Floor( Area(ft) n/a 19 Natural Gas Available Yes 20 Addition Slab A(reafftz pl )> n!a \ 21 Glazing Percentage (%) 31.2% COMPLIANCE RESULTS 01 i . yr s. r-�:rr-s Building Complies withslomputer,P��rformane ^ 02 i . �.:. • K �� ' �� p + sa �+� z+ , is �� This building mcorporateifeafures,�that regwre field test�and/oryerifica6on�by a,certified HERS Aate�underathe supervision of a CEC-approved HERS provider. 03 n eqr,�i x wwsxa ss fi i !� i This building- p' rporates one o_r.r or�Special Feat�ressk own below , /0 / ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) andard D ign Proposed Design Compliance Margin Percent Improvement Space Heating 9.47 -5.10 -116.7% Space Cooling 91.57 79.02 12.55 13.7% IAQ Ventilation 0.76 0.76 0.00 0.0% Water Heating 1.30 2.32 -1.02 -78.5% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 98.00 91.57 6.43 1 6.6% Registration Number: 218.P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project rvame: Madison Custom Residence uaiuulation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - Page c of 16 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency:= EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 46.1 43.4 0.0 43.4 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the.modi3led energyjperformance foriAhis computer analysis.� • Cool roof r • Window overhangs and/or fins • Non-standard duct location (any location other than attic)_' • Central parallel piping E HERS FEATURE SUMMARY -1,,, Q " � The following is a summary of the features that must be field- v 'fi d by a certiEi d* ERS¢Raje-r s a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. O `�0�,� Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8) Domestic Hot Water System Verifications: • — None -- Registration Number: 218-P010096029A-000-000-0000000-0000 Registration DatefTime: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF 'E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project name: Madison Custom Residence L aiaulation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF RF-01 - Page a of 16 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Custom Residence 12597 1 10 9 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 master Conditioned HVAC mstrl 1713 11 DHW Sys 1 n/a great Conditioned HVAC great2 1586 11 DHW Sys 1 n/a liv kit Conditioned HVAC liv3 1660 11 DHW Sys 1 n/a media Conditioned HVAC media4 1355 11 DHW Sys 1 n/a bed3 Conditioned HVAC media4 388 11 DHW Sys 1 n/a bed 1 2 Conditioned HVAC beds 1580 11 DHW Sys 1 n/a guest Conditioned HVAC,g9t6*" ` 1 11 _ DHW Sys 1 n/a guest main Conditioned AOAMC 6stmn7 2373 # Ifl 1 f DHW Sys 1 n/a garage Conditioned HVA&Garaget M 'Jk '�71281 W N11 ' 0 DHW Sys 1 n/a V, oq00 O ti Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence l.a...lation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - P;.,y� , of 16 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ftZ) Tilt (deg) 20d Wall master R-21 Wall (W.21.2x6.16) 20 Right 630 165.9 90 110d Wall master R-21 Wall (W.21.2x6.16) 110 Front 630 0 90 200d Wall master R-21 Wall (W.21.2x6.16) 200 Left 1070 210.8 90 290d Wall master R-21 Wall (W.21.2x6.16) 290 Back 1070 275.9 90 Interior Surface master»great R-0 Interior Wall n/a n/a 410 0 n/a Roof master R-38 Roof Flat n/a n/a 1713 n/a n/a 20d Wall 2 great R-21 Wall (W.21.2x6.16) 20 Right 390 98.1 90 110d Wall 2 great R-21 Wall (W.21.2x6.16) 110 Front 798 232.46 90 200d Wall 2 n great R-21 Wall (W.21.2x6.16) 200 Left 590 126.2 90 290d Wall 2 ��✓,a'great R-21 Wall (W.21.2x6.16) 290 Back 798 236.412 90 Interior Surface 2 /egeat'r>Iyv kit, R-0 Interior Wall n/a n/a 382 0 n/a Roof 2 ��t atN R-38 Roof Flat n/a n/a 1586 n/a n/a 20d Wall 3 ,0� �A°�� Iry lci� c Ft� 21 Wall ((W 2 2x6 1 0 tRight 1080 93.408 90 110d Wall 3 C� liv kit"'9{�}��, `/� R 21Wall (VU 21.2 xfi 6 1^a LL 1 0Eront _ 288 0 90 200d Wall 3 vLlv)K!� p �.��%� R 21 W (W.21.2x6.16) 00� Lefty „`u Y 722 321.53 90 290d Wall 3 liv kII ° �` R-2�1 Wall'(W.21 2x6.16)- �- 2*90 f' I B ck 836 214.99 90 Interior Surface 3 b kit»be�3% `� R-0 Interior Wall n/a n/a 410 0 n/a Roof 3 iv kit R-38 Roof Flat n/a n/a 1660 n/a n/a 20d Wall 4 R-21 Wall (W.21.2x6.16) 20 Right 900 240 90 110d Wall 4 medi R-21 Wall (W.21.2x6.16) 110 Front 288 0 90 200d Wall 4 media R-21 Wall (W.21.2x6.16) 200 Left 1070 489 90 290d Wall 4 media R-21 Wall (W.21.2x6.16) 290 Back 288 0 90 Interior Surface 4 media»master R-0 Interior Wall n/a n/a 410 0 n/a Interior Surface 5 media»garage R-13 Wall n/a n/a 76 0 n/a Roof 4 media R-38 Roof Flat n/a n/a 1355 n/a n/a 20d Wall 5 bed3 R-21 Wall (W.21.2x6.16) 20 Right 416 141.5 90 Interior Surface 6 bed3»bed 1 2 R-0 Interior Wall n/a n/a 122 0 n/a Interior Surface 7 bed3»bed 1 2 R-0 Interior Wall n/a n/a 122 0 n/a Interior Surface 8 bed3»bed 1 2 R-0 Interior Wall n/a n/a 122 0 n/a Roof 5 bed3 R-38 Roof Flat n/a n/a 388 n/a n/a Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Dateffime: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence Uai�ulation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - PayC a of 16 20d Wall 6 bed 1 2 R-21 Wall (W.21.2x6.16) 20 Right 516 36 90 50d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 50 - specify - 880 87 90 140d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 140 - specify - 880 24 90 230d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 230 - specify - 583 63 90 290d Wall 5 bed 1 2 R-21 Wall (W.21.2x6.16) 290 Back 288 0 90 Interior Surface 9 bed 1 2»guest R-0 Interior Wall n/a n/a 410 0 n/a Interior Surface 10 bed 1 2»garage R-13 Wall n/a n/a 172 0 n/a Roof 6 bed 1 2 R-38 Roof Flat n/a n/a 1580 n/a n/a 50d Wall 2 guest R-21 Wall (W.21.2x6.16) 50 - specify - 528 0 90 140d Wall 2 guest R-21 Wall (W.21.2x6.16) 140 - specify - 528 95 90 230d Wall 2 guest R-21 Wall (W.21.2x6.16) 230 - specify - 528 173.5 90 320d Wall guest R-21 Wall (W.21.2x6.16) 320 - specify - 288 30 90 Interior Surface 11 guest»guest main R-0 Interior Wall n/a n/a 288 0 n/a Roof 7 guest R-38 Roof Flat n/a n/a 661 n/a n/a 20d Wall 7 guest main R-21 Wall (W.21.2x6_16)� ' 20 Right 990 253 90 50d Wall 3 guest main , RK21,, aW (1N➢21 2z6,t 6)� ; i50 specify - 630 0 90 110d Wall 5 guest main ] ' 9 $$ y R 21 WaII�W 29 2x6:1 }J/�' V � l e ,a i I10 w. F o t ; k W 288 0 90 140d Wall 3 guest,main � . R-21 seecify s4 630 0 90 200d Wall 5 guest man f- FW.21i2x816 Deft\ 990 78 90 290d Wall 6 guest main R-21 II 21.2x6.16) U9a0® n' gr 50> 990 273 90 Interior Surface 12 guest main»master R-0 Inte " r II (n/ 455 0 n/a Roof 8 guest main R-38 Roof Fla B n/a7/� n/a 2373 n/a n/a 50d Wall 4 garage R-21 Wall (W.21.2x6.16) 50 spe fy - 425 288 90 140d Wall 4 garage R-21 Wall (W.21.2x6.16) 0 - ecify - 190 0 90 320d Wall 2 garage R-21 Wall (W.21.2x6.16) 3 specify - 105 0 90 Interior Surface 13 garage»bed 1 2 R-13 Wall n/a n/a 172 0 n/a Interior Surface 14 garage»media R-13 Wall n/a n/a 76 0 n/a Roof 9 garage R-38 Roof Flat n/a n/a 1281 n/a n/a Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Name: Madison Custom Residence (,4..u.ation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - Pi.y- ., of 16 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic master Attic Roofmaster Ventilated 0 0.62 0.81 Yes Yes Attic great Attic Roofgreat Ventilated 0 0.62 0.81 Yes Yes Attic liv kit Attic Roofliv kit Ventilated 0 0.62 0.81 Yes Yes Attic media Attic Roofinedia Ventilated 0 0.62 0.81 Yes Yes Attic bed3 Attic Roofbed3 Ventilated 0 0.62 0.81 Yes Yes Attic bed 1 2 Attic Roofbed 1 2 Ventilated 0 0.62 0.81 Yes Yes Attic guest Attic Roofguest Ventilated 0 0.62 0.81 Yes Yes Attic guest main Attic Roofguest main Ventilated 0 0.62 0.81 Yes Yes Attic garage Attic Roofgarage Ventilated 0 0.62 0.81 Yes Yes co Fp sP R (0 V I D i ST,9����F,oT'Q TKO ey ti Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTII 'E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence Uaiculation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF RF-01 Page r' of 16 FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading 06d Window 20d Wall (Right-20) - - 1 165.9 0.51 0.22 Insect Screen (default) 04d Window 200d Wall (Left-200) - - 1 91.0 0.35 0.23 Insect Screen (default) 05d Window 200d Wall (Left-200) - - 1 30.0 0.35 0.23 Insect Screen (default) 02 Window 200d Wall (Left-200) - -- 1 40.0 0.35 0.23 Insect Screen (default) 04 Window 200d Wall (Left-200) - - 1 30.0 0.49 0.19 Insect Screen (default) 39 Window 200d Wall (Left-200) - - 1 19.8 0.49 0.27 Insect Screen (default) 022 Window 290d Wall (Back-290) - - 1 40.0 0.49 0.19 Insect Screen (default) 06d 2 �� °f L. window 290d Wall (Back-290) - - 1 165.9 0.51 0.22 Insect Screen (default) 05 v�/ �Winc�oW� 290d Wall (Back-290) - - 1 70.0 0.46 0.17 Insect Screen (default) 36� A f v�V(-,Windo4i �" 20d Wall 2 (Right-20) - - 1 98.1 0.35 0.23 Insect Screen (default) /0,1d Oqy Wn�ow 110d Wall 2 (Front-110) 19.7 11.8 1 232.5 0.51 0.22 Insect Screen (default) �00 �` �- 6'VVdo 200d'Wall 2 (Left-200) 8:Oa 10.0 1 _80.0 0.35 0.23 Insect Screen (default) 38 �lindo0 Wall 2(Left 200) 1' 23.1 0.35 0.23 Insect Screen (default) 37 Wi ' 4 2w tl`1Na11:2 (Left-200) -r*. V 91 V ' lli*23rt1 0.35 0.23 Insect Screen (default) 07d Y Window 0 � �-a 90d Wall 2 Back-290 19.7,E V1.8 1.017 j.236.4 0.51 0.22 (default) Insect Screen default 06 indow 20d Wall 3 (Right-20) 8.0 7.0 0.668 37.4 0.35 0.23 Insect Screen (default) 07 20d Wall 3 (Right-20) 8.0 7.0 1 56.0 0.35 0.23 Insect Screen (default) 08d Windo 200d Wall 3 (Left-200) 14.5 11.0 1 159.5 0.51 0.22 Insect Screen (default) 09d Window 200d Wall 3 (Left-200) 16.5 10.0 0.982 162.0 0.47 0.17 Insect Screen (default) 08d 2 Window 290d Wall 3 (Back-290) 11.5 10.0 1 115.0 0.51 0.22 Insect Screen (default) 09d 2 Window 290d Wall 3 (Back-290) 11.0 10.0 0.909 100.0 0.51 0.22 Insect Screen (default) 08 Window 20d Wall 4 (Right-20) 8.0 10.0 1 80.0 0.35 0.23 Insect Screen (default) 11d Window 20d Wall 4 (Right-20) 16.0 10.0 1 160.0 0.46 0.17 1 Insect Screen (default) 23 Window 200d Wall 4 (Left-200) 9.5 10.0 1 95.0 0.35 0.23 Insect Screen (default) 22d Window 200d Wall 4 (Left-200) 16.0 10.0 1 160.0 0.49 0.19 Insect Screen (default) 24 Window 200d Wall 4 (Left-200) - - 1 78.0 0.35 0.23 Insect Screen (default) 26 Window 200d Wall 4 (Left-200) - -- 1 78.0 0.35 0.23 Insect Screen (default) 27 Window 200d Wall 4 (Left-200) -_4 -- 1 78.0 0.35 0.23 Insect Screen (default) 082 Window 20d Wall 5 (Right-20) 8.0 10.0 1 80.0 0.49 0.19 Insect Screen (default) Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence l.am;ulation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF ZF-01 - Puy- „ of 16 11 Window 20d Wall 5 (Right-20) 8.0 6.0 1 48.0 0.49 0.19 Insect Screen (default) 09 Window 20d Wall 5 (Right-20) - - 1 13.5 0.49 0.19 Insect Screen (default) 12 Window 20d Wall 6 (Right-20) - - 1 36.0 0.49 0.19 Insect Screen (default) 13 Window 50d Wall (- specify -50) - - 1 15.0 0.49 0.19 Insect Screen (default) 14 Window 50d Wall (- specify -50) -- - 1 21.0 0.49 10.19 Insect Screen (default) 12d Window 50d Wall (- specify -50) - - 1 30.0 0.32 0.25 Insect Screen (default) 16 Window 50d Wall (- specify -50) -- - 1 21.0 0.49 0.19 Insect Screen (default) 21 Window 230d Wall (- specify -230) - - 1 48.0 0.46 0.17 Insect Screen (default) 22 Window 230d Wall (- specify -230) - - 1 15.0 0.49 0.19 1 Insect Screen (default) 17 Window 140d Wall 2 (- specify -140) - - 1 80.0 0.49 0.19 Insect Screen (default) 18 Window 140d Wall 2 (- specify -140) - - 1 15.0 0.49 0.19 Insect Screen (default) 19 ,Window: 230d Wall 2 (- specify -230) 8.0 10.0 1 80.0 0.49 0.19 Insect Screen (default) 21 2 ..Windorw1 230d Wall 2 (- specify -230) 8.0 10.0 1 80.0 0.49 0.19 Insect Screen (default) 222 -� , Window`' �✓ 0 230d Wall 2 (- specify -230) -- - 1 13.5 0.49 0.19 Insect Screen (default) 21d �✓ Windo Wall (- specify -320) 5.0 6.0 1 30.0 0.49 0.19 Insect Screen (default) 26d WAt Od' all 7 (Right-20)~ � 3 =` � f = 1 128.0 0.51 0.22 Insect Screen (default) 30 �� coy Window /rJA d Wall 7 Right20) '� t i 1�` 30.0 0.49 0.19 Insect Screen (default) 232 Window 20dWallr7 (Right-20): �. f -'� 1 950 0.49 0.17 Insect Screen (default) 28 i ow# 200d Walls (Left�200),� R - 1� �48.0 0.35 0.23 Insect Screen (default) 29 Win 200d Wall 5 (Left-200) - - 1 15.0 0.49 0.19 Insect Screen (default) 31 Window 200d Wall 5 (Left-200) - - 1 15.0 0.49 0.19 Insect Screen (default) 26d 2 Window 290d Wall 6 (Back-290) - - 1 60.0 0.49 0.19 Insect Screen (default) 27d Window 290d Wall 6 (Back-290) - - 1 135.0 0.51 0.22 Insect Screen (default) 32 Window 290d Wall 6 (Back-290) - - 1 78.0 0.35 0.23 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 140d Wall 24.0 0.50 Door 2 50d Wall 4 72.0 0.08 Door 3 50d Wall 4 72.0 0.08 Door 4 50d Wall 4 72.0 0.08 Door 5 50d Wall 4 72.0 0.08 Registration Number: 218-P010096029A-000-000-0000000-0000 Registration DateMme: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Name: Madison Custom Residence ums;uiation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - Payc .7 of 16 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 01d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 00 14 0.1 14 14 0 0 0 0 0 0 0 0 0 07d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 06 12 0.1 12 12 0 0 0 0 0 0 0 0 0 07 12 0.1 12 12 0 0 0 0 0 0 0 0 0 08d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 09d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 08d 2 AA4�`,, 0.1 14 14 0 0 0 0 0 0 0 0 0 09d2 ' ✓14k �0.1 14 14 0 0 0 0 0 0 0 0 0 08 / a0� C— � �1� 10 10 0 0 0 0 0 0 0 0 0 11 d �`�?2� �j , 0:1 12 12t 0 '0 0 0 0 0 0 0 0 23 q� 2 50.1,�2 `C:12 0 0 0 f0 0 0 0 0 0 22d d$.0% c1a 12s 50 1 Iff 0 0 0% 0 0 0 0 0 08 2 12 0'1� "..~ 12 > 0' —`0 0. 0 0 0 0 0 0 11 C �2 12 0 0 0 0 0 0 0 0 0 19 1Q, 0. 10 10 0 0 0 0 0 0 0 0 0 212 1 0.1 0 10 0 0 0 0 0 0 0 0 0 21d 14 0.1 14 14 0 1 0 0 0 0 0 0 0 0 WIA Registration Number: 218-P010096029A-000-000-0000000-0000 Registration DatelTime: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF 'E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence l.amulation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF RF-01 - Page- iv of 16 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Flat attic) W e • Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing/Insulation: R6 Sheathing R-21 Wall (W.21.2x6.16) E •or Walls r II 2x6 @ 16 in. O.C. R 21 0.045 Exterior Finish: 3 Coat Stucco 9Z% , �? Inside Finish: Gypsum Board Cavity/Frame: no insul. /2x4 R-0 Interior Wall Interio Its 1Q(� �e� a 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board r o Chord of. Roof. Truss @ 24 Cavity/Frame: no insul. /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Attic Roofgreat Attic Roofs �•�' >e �l od Fr e4t ate• fin. O.0 " none: 0 644 Roofing: Light Roof (Asphalt Shingle) �/O t 44�_. 4 2z4 T ,Chord of�Roof Truss(@ 24_-" Cavity/Frame: no insul. /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Attic Roofliv kit Attic Roofs ramed Ceiling- � / � in. O.C. v,, � ,� it no r 0 644 Roofing: Light Roof (Asphalt Shingle) � r_ f A. �F V i %—.e ' — 3 Cavity/Frame: no insul. /2x4 Top Chrd �Fr\,�C4ing 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic Roofinedia Attic Roofs Wood in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofbed3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofbed 1 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofguest Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofguest main Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Registration Number: 218-P010096029A-000-000-0000000-0000 Registration DatelTime: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Fame: Madison Custom Residence (.......ation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - Pa" .. of 16 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgarage Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 % `s/ 02 03 04 05 06 07 Name �� r' Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab Q�n din ter 1713 172 None 0.8 No Slab 2� Cg Mgr a 1586 91 None 0.8 No Slab 3 1660 151 None 0.8 No Slab �?c v/ S� Fp 1355 196 None 0.8 No Slab 5 ,6dam 388 28 None 0.8 No Slab 6 B bed 1 PV 1580 162 None 0.8 No Slab 7 guest 661 115 None 0.8 No Slab 8 g t n 2373 240 None 0.8 No Slab 9 garage 1281 168 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 4 02 g 0Y 04 Quality Insulation Installation (QII) Qualityn tallat on of Sp'`ray Foam nsulat on'0 4MWWB ldingCE `elope Ai' Le kage CFM50 Required aJ'j NotWequired �-j Q V ( .•Not Required, n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small Storage 2 50 0.66 EF 40,000 Btu/hr R-0/R-0 n/a n/a n/a Na Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I IOD Project Name: Madison Custom Residence Lmuuiation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF ZF-01 - Pay. . , of 16 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC mstrl Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 System HVAC great2 Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 System HVAC liv3 Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 System HVAC media4 Other Heating and Cooling Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 System HVAC beds Other Heating and Cooling Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 System HVAC gst6 Other Heating and Cooling Heating Component 6 Cooling Component 6 HVAC Fan 6 Air Distribution System 6 System HVAC gstm Other Heating and Cooling Heating Component 7 Cooling Component 7 HVAC Fan 7 Air Distribution System 7 System HVAC ara e8 � g e Pump Heating and ' ! System 1 � '� s Heat Pump S stem 8 yam, k €A Heat Pump System 8 None -none - VG1 4C ing ; j t HVAC - HEATING I ES *11310 ° kj ^ 1 VCR `� g, p �-.p ; ,Je�� t S 02 §"' w hC 3 p 1, 04 Na e System Type Number of Units Efficiency Heating Compo B %fir / CntrtFumace 1 80 AFUE Heating Component V CntrlFumace 1 80 AFUE Heating Component 3 CntrlFumace 1 80 AFUE Heating Component 4 CntrlFumace 1 80 AFUE Heating Component 5 CntrlFumace 1 80 AFUE Heating Component 6 CntrlFurnace 1 80 AFUE Heating Component 7 CntrlFumace 2 80 AFUE HVAC - HEAT PUMPS 01 02 03 04 05 1 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 8 DuctlessMiniSplitHeatPump 2 8.3 32000 19200 13.1 11 Not Zonal Single Speed Heat Pump System 8-hers-cool Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 1 OD Project Name: Madison Custom Residence Gwa ; ..ation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF IF-01 - Payc of 16 HVAC - COOLING UNIT TYPES - 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 13 16 Zonally Controlled Single Speed Cooling Component 4-hers-cool Cooling Component 5 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 5-hers-cool Cooling Component 6 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 6-hers-cool Cooling Component 7 SplitAi and 2 13 16 Not Zonal Single Speed Cooling Component 7-hers-cool 4 go V + HVAC COOLING - HERS VERIFICATION v �� �� s ! j 99 01 � ,s,• p A w. � �� 2:0 ,P1 w -. WORTS 0 E# le 03 - - - 044 :i � -- - ai 05 06 Name /0' '+- 'TT �%g ' ied��rFl9w 4T // + i Airflow Target ) � Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-coo q�fe' 350 Required Required Required Cooling Component 2-hers-cool Require C e 350 Required Required Required Cooling Component 3-hers-cool OWquired 350 Required Required Required Cooling Component 4-hers-cool Ru d 350 Required Required Required Cooling Component 5-hers-cool Require 350 Required Required Required Cooling Component 6-hers-cool Required 350 Required Required Required Cooling Component 7-hers-cool Required 350 Required Required Required Heat Pump System 8-hers-cool Not Required n/a Not Required Not Required Required Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Name: Madison Custom Residence Gaeumation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF W-01 - Pay. of 16 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System Air Distribution System 1 Y Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None 1-hers-dist Air Distribution System Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None 2-hers-dist Air Distribution System Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None 3-hers-dist Air Distribution System Air Distribution System 4 Y Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None 4-hers-dist Air Distribution System Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None 5-hers-dist Air Distribution System Air Distribution System 6 DuctsAttic Sealed and tested 8 Attic None 6-hers-dist Air Distribution System Air Distribution System 7 DuctsAttic Sealed and tested 8 Attic None 7-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION'. 04 07 08 01 62 { 03 L05 06 Name era•,. • Duct Leakage Verification 3 s= ��_���Duct Leakage _ i"-" 7 Target (%) � ....•a no, m Venfied Duct L cat"io 0 «.�-�^vr 3rY xc ra Venfied Duct �)v gn D ..•...4y :� Buned Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 2-hers-list Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 4-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 5-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 6-hers-list Required 5.0 Not Required Not Required Not Required Not Required I n/a Air Distribution System 7-hers-list Required 5.0 Not Required Not Required Not Required Not Required n/a Registration Number: 218-P010096029A-000-000-0000000-0000 Registration Date/Time: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Name: Madison Custom Residence l.a.—ation DatelTime: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF ZF-01 - Pay� Of 16 HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5-hers-fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan 6-hers-fan HVAC Fan 7 Single Speed PSC Furnace Fan 0.58 HVAC Fan 7-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan a4e lltWftRequited 0.58 HVAC Fan 3-hers-fan ,R quired 0.58 HVAC Fan 4-hers-fan �. L.'Re wired U q, , 1 0.58 HVAC Fan 5-hers-fan b C_ t> Required-°-., k jr �t 1---% r_— 0 0.58 HVAC Fan 6-hers-fan ~ - .. Required 0.58 HVAC Fan 7-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAOVentRpt 208 0.25 Default 0 Required Registration Number: P78-Po10096029A-000-000-0000000-0000 Registration DateMme: 2018-04-04 15:56:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-04-04 15:50:40 CERTIF E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Name: Madison Custom Residence Ga..;...ation Date/Time: 15:49, Wed, Apr 04, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4823.tmp.xml CF 2F-01 - Payc , of 16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: %crr�'�cai Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-04-04 15:56:46 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design'features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted t� ogthe enforcementagency four apprroovall with. h s_building permit application. Responsible Designer Name: a4 s iResponsible 5esigner Signature T Tim Scott 0 Company: Date Signed: s Scott Design and Title 24, Inc. 9 6� 2018-04 04�15:5�6:4w Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 218-P010096029A-000-000-0000000-0000 Registration DateMme: 2018-04-04 15:56:46 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 ❑ ❑ ❑ HERS Provider: CaICERTS inc. Report Generated at: 2018-04-04 15:50:40 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Madison Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 41412018 Project Address Lot 19B - Madison Club La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 12,597 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ftz Special Features Status Roof Wood Framed Attic R 38 12,597 Cool Roof New Wall Wood Framed R 21 17,874 Add=R-6.0 New Slab Unheated Slab -on -Grade no insulation 12,597 Perim = 1323' New Demising Wood Framed no insulation 3,131 New Demising Wood Framed R 13 496 New Door Opaque Door no insulation 24 New Door Opaque Door no insulation 288 Add=R-12.0 New FENESTRATION Orientation Area ft2 Total Area: 3,935 Glazing Percentage: 31.2% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.46 Exterior Shades Status Right (N) 165.9 0.510 0.22 none none Bug Screen New Left (S) 91.0 0.350 0.23 none none Bug Screen New Left (S) 70.0 0.350 0.23 none none Bug Screen New Lek (S) 30.0 0.490 0.19 none none Bug Screen New Left (S) 19.8 0.490 0.27 none none Bug Screen New Rear (W) 40.0 0.490 0.19 none none Bug Screen New Rear (W) 165.9 0.510 0.22 none none Bug Screen New Rear (W) 70.0 0.460 0.17 none none Bug Screen New Right (N) 98.1 0.350 0.23 none none Bug Screen New Front (E) 232.5 0.510 0.22 14.0 none Bug Screen New Leff (S) 80.0 0.350 0.23 14.0 none Bug Screen New Left (S) 328.2 0.350 0.23 none none Bug Screen New Rear (W) 236.4 0.510 0.22 14.0 none Bug Screen New Right (N) 93.4 0.350 0.23 12.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC mstr Ducted Ducted Conditioned 8.0 New HVAC great Ducted Ducted Attic 8.0 New HVAC liv Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Storage Gas 50 0.66 Parallel Piping New EnerqyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 19 of 59 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Madison Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 41412018 Project Address Lot 19B - Madison Club La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 12,597 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ffz Special Features Status FENESTRATION Orientation Area ft2 I Total Area: 3,935 Glazing Percentage: 31.2% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.46 Exterior Shades Status Left (S) 159.5 0.510 0.22 14.0 none Bug Screen New Leff (S) 162.0 0.470 0.17 14.0 none Bug Screen New Rear (W) 115.0 0.510 0.22 14.0 none Bug Screen New Rear (W) 100.0 0.510 0.22 14.0 none Bug Screen New Right (N) 80.0 0.350 0.23 10.0 none Bug Screen New Right (N) 160.0 0.460 0.17 12.0 none Bug Screen New Left (S) 95.0 0.350 0.23 12.0 none Bug Screen New Left (S) 160.0 0.490 0.19 12.0 none Bug Screen New Right (N) 80.0 0.490 0.19 12.0 none Bug Screen New Right (N) 48.0 0.490 0.19 12.0 none Bug Screen New Right (N) 13.5 0.490 0.19 none none Bug Screen New Right (N) 66.0 0.490 0.19 none none Bug Screen New Right (NE) 57.0 0.490 0.19 none none Bug Screen New Right (NE) 30.0 0.320 0.25 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC media Ducted Ducted Conditioned 8.0 New HVAC bed Ducted Ducted Attic 8.0 New HVAC gst Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener-gyPro 7.2 by Ener.QySoft User Number: 6712 ID: Page 20 of 59 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Madison Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 41412018 Project Address Lot 19B - Madison Club La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 12,597 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ft Special Features Status FENESTRATION Orientation Area ft2 I Total Area: 3,935 Glazing Percentage: 31.2% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.46 Exterior Shades Status Left (SM 48.0 0.460 0.17 none none Bug Screen New Left (SW) 15.0 0.490 0.19 none none Bug Screen New Front (SE) 95.0 0.490 0.19 none none Bug Screen New Left (SW) 160.0 0.490 0.19 10.0 none Bug Screen New Left (SW) 13.5 0.490 0.19 none none Bug Screen New Rear (NW) 30.0 0.490 0.19 14.0 none Bug Screen New Right (N) 128.0 0.510 0.22 none none Bug Screen New Right (N) 95.0 0.490 0.17 none none Bug Screen New Left (S) 30.0 0.490 0.19 none none Bug Screen New Rear (W) 60.0 0.490 0.19 none none Bug Screen New Rear (M 135.0 0.510 0.22 none none Bug Screen New Rear (M 78.0 0.350 0.23 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Split Heat Pump 8.30 HSPF Split Heat Pump 13.1 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC gstmn Ducted Ducted Attic 8.0 New HVAC Garage Ductless / with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnenqvPro 7.2 by EnengySoft User Number: 6712 ID: Page 21 of 59 e2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Orioinal 08/2016) Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.E-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110 7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CFI R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of 110.8(g). § 150.0(g)l: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fittingtight-fifting damper or combustion -air control device.' § 150.0(e)lC: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. 0 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.06)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class 11 vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0. 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of Flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or Flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m l land Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. F �� � 2016 Low -Rise Residential Mandatory Measures Summary IDuct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. a2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 150.0 k 3A or with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9 130.0, 130.2,130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4,140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0,130.1. 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 1 10.10b through § 1 10.10e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)l: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 1 10.10c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC mstr Floor Area 1,713 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,012 Return Vented Lighting Return Air Ducts Return Fan Ventilation 314 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 28,613 2,179 790 30,510 Total Output Btuh 89,000 0 Output Btuh/s ft 52.0 0 0 Cooling System 0 0 Output per System 57,500 12,366 2,545 314 14,706 Total Output Btuh 57,500 2,943 0 1 43,922 4,725 -2,943 Total Output Tons 4•8 0 Total Output Btuh/s ft 33.6 Total Output s ft/Ton 357.5 42,272 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANA760/58PH"110 43,747 9,878 89,000 Airflow cfm/s ft 1.17 Airflow cfm/Ton 417.4 Outside Air % 15.7% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 43,747 9,878 89,000 Outside Air cfm/s ft 0.18 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 314 cfm 70 OF 64 OF 106 OF 106 OF ► ���� Heating Coil Supply Fan o 106 F 2,000 cfm ROOM 70 OF �J--1-U COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 314 cfm 75 / 65 OF 82/68OF 62/60OF 62/60OF � Cooling Coil Supply Fan 62 / 60 OF 2,000 cfm ` 60.1% ROOM 75 / 65 OF EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 26 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC great Floor Area 1,586 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,889 Return Vented Lighting Return Air Ducts Return Fan Ventilation 291 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 25,463 2,018 693 26,319 Total Output Btuh 89,000 0 Output Btuh/s ft 56.1 1,470 1,293 Cooling System 0 0 Output per System 57,500 11,236 2,391 291 13,427 Total Output Btuh 57,500 2,943 4,409 -2.943 Total Output Tons 4.8 1,470 1,293 Total Output Btuh/s ft 36.3 Total Output s ftfTon 331.0 1 42,582 39,390 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANA760/58PH"110 44,071 9,545 89,000 Airflow cfm/s ft 1.26 Airflow cfm/Ton 417.4 Outside Air % 14.5% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 44,071 9,545 89,000 Outside Air cfm/s ft 0.18 Jan 1 AM Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 291 cfm 69 OF 64 OF 106 OF 106 OF PEI Heating Coil Supply Fan 2,000 cfm 106 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 291 cfm 76/65°F 82/68°F 62/60°F 62/60°F 0 Cooling Coil Supply Fan 62 / 61 OF 2,000 cfm v, 59.9% ROOM 75/65°F EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 27 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC liv Floor Area 1,660 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,854 304 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 24,659 2,112 762 28,601 Total Output Btuh 89,000 0 Output Btuh/s ft 53.6 1,424 1,406 Cooling System 0 0 Output per System 57,500 11,767 2,379 304 14,037 Total Output Btuh 57,500 2,943 4,491 -2,943 Total Output Tons 4•8 1 1,424 1,406 Total Output Btuh/s ft 34.6 Total Output s ftfTon 346.4 42,216 42,505 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANA760/58PH"110 44,155 9,621 89,000 Airflow cfm/s ft 1.20 Airflow cfmfTon 417.4 Outside Air % 15.2% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 44,155 9,621 89,000 Outside Air(cfm /s ft 0.18 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 304 cfm 69 IF 64 OF 106 OF momil Heating Coil Supply Fan 2,000 cfm � l-E 106 OF ° 105 F ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 304 cfm 76/66°F 83/68°F 62/61 OF 62/61 Cooling Coil Supply Fan 2,000 cfm OF 63 / 61 OF 60.4% ROOM 75/65°F EnergyPro 7.2 by EnergySoft User Number. 6712 ID: Page 28 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC media Floor Area 1,743 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 2,000 F 320 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 28,259 2,217 874 33,633 Total Output Btuh 89,000 0 Output Btuh/s ft 51.1 0 0 Cooling System 0 0 Output per System 57,500 12,583 2,535 320 14,963 Total Output Btuh 57,500 2,943 4,752 -2,943 Total Output Tons 4.8 0 0 Total Output Btuh/s ft 33.0 Total Output s ftITon 363.8 1 43,785 45,652 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANA760/58PH"110 43,790 9,903 89,000 Airflow cfm/s ft 1.15 Airflow cfm/Ton 417.4 Outside Air % 16.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 43,790 9,903 89.000 Outside Air cfm/s ft 0.18 'Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 320 cfm 70 OF 64 OF 106 OF f C�) Heating Coil Supply Fan 2,000 cfm ff �EE A _ _ 106 OF ' �1_ A 106 OF ROOM Im 0 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 320 cfm 75/65°F 82/68°F 62/61 OF 62/61 OF / 61 OF Cooling Coil Supply Fan 2,000 2,000 cfm 60.3% ( ROOM' 75/65°F EnergyPro 7.2 by EnergySoff User Number: 6712 ID: Page 29 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC bed Floor Area 1,580 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,273 Return Vented Lighting Return Air Ducts Return Fan Ventilation 290 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 17,614 2,010 552 21,117 Total Output Btuh 89,000 0 Output Btuh/s ft 56.3 1,017 1,038 Cooling System 0 0 Output per System 57,500 11,259 2,448 290 13,414 Total Output Btuh 57,500 2,943 4,458 -2,943 Total Output Tons 4.8 1,017 1,038 Total Output Btuh/s ft 36.4 Total Output s ft[Ton 329.7 1 33,849 33,663 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANA760/58PH"110 43,910 9,603 89,000 Airflow cfm/s ft 1.27 Airflow cfm/Ton 417.4 Outside Air % 14.5% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 43,910 9,603 89,000 Outside Air cfm/s ft 0.18 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 290 cfm 70 OF -d S� 65 OF 106 OF 106 OF Heating Coil Supply Fan 2,000 cfm 106 OF ROOM M 70 of 4 LLEEU COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 290 cfm 75 / 65 OF -d 82/68OF 62/60OF 62/60OF i O -[-U Cooling Coil Supply Fan 62 / 61 OF 2,000 cfm 59.7% ROOM Jfl 75 / 65 OF 4 U-1-FA 4 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 30 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC gst Floor Area 661 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 683 Return Vented Lighting Return Air Ducts Return Fan Ventilation 121 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 11,710 841 296 15,749 Total Output Btuh 71,000 0 Output Btuh/s ft 107.4 676 774 Cooling System 0 0 Output perSystem 36,000 4,703 1,764 121 5,596 Total Output Btuh 36,000 0 2,605 0 Total Output Tons 3.0 676 774 Total Output Btuh/s ft 54.5 Total Output s ft/Ton 220.3 17,766 22,893 Air System CFM erS stem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANA736/58PH"0110 26,642 5,455 71,000 Airflow cfm/s ft 1.82 71,000 Jan 1 AM Airflow cfm/Ton 400.0 Outside Air % 10•1% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 26,642 5,455 Outside Air cfm/s ft 0.18 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 121 cfm 69 OF 65 OF 121 OF 121 OF Heating Coil Supply Fan 1,200 cfm ° 120F ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 121 cfm 76 / 64 OF 79/65°F 58/57°F 58/57°F � Cooling Coil Supply Fan 1,200 cfm U_ I 59 / 57 OF 53.0% ROOM 75/63 OF ' EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 31 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC gstmn Floor Area 2,373 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,190 Return Vented Lighting Return Air Ducts Return Fan Ventilation 435 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 33,055 3,019 915 36,636 Total Output Btuh 178,000 0 Output Btuh/s ft 75.0 1,908 1,801 Cooling System 0 0 Output per System 57,500 16,923 4,724 435 20,176 Total Output Btuh 115,000 5,887 1,908 1 59,681 7,743 -5,887 Total Output Tons 9.6 1,801 Total Output Btuh/s ft 48.5 Total Output s ft/Ton 247.6 54.526 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 24ANA760/58PH"110 87,007 18,083 178,000 Airflow cfm/s ft 1.69 Airflow cfm/Ton 417.4 Outside Air % 10•9% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 87,007 18,083 178,000 Outside Air cfm/s ft 0.18 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF Outside Air 435 cfm 70 OF 66 OF 108 OF 108 OF Heating Coil Supply Fan o 4,000 cfm 108 F c: ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 435 cfm 75 ! 65 OF 81/67OF 60/59OF ^^ 60/59OF rn� _ Cooling Coil Supply Fan 61 / 59 OF 4,000 cfm 57.1%u I ROOM 75 ! 64 OF EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 32 of 59 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Custom Residence Date 4/4/2018 System Name HVAC Garage Floor Area 1,281 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 415 Return Vented Lighting Return Air Ducts Return Fan Ventilation 235 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 32,000 9,677 1,630 717 11,666 Total Output Btuh 64,000 0 Output Btuh/s ft 50.0 0 0 Cooling System 0 0 Output perSystem 30,000 9,247 5,485 235 10,997 Total Output Btuh 60,000 0 0 1 18,924 7,114 0 Total Output Tons 5•0 0 Total Output Btuh/s ft 46.8 Total Output s ft/Ton 256.2 22,663 Air System CFM perSystem 890 HVAC EQUIPMENT SELECTION Airflow cfm 1,780 Fujitsu Ductless Split 50,753 1.053 39,973 Airflow cfm/s ft 1.39 39,973 Jan 1 AM Airflow cfm/Ton 356.0 Outside Air % 13.2% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 50,753 1,053 Outside Air cfm/s ft 0.18 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 64 OF 64 OF 85 OF Outside Air PJ -0. U-1—LEU 235 cfm Supply Fan Heating Coil 1,780 cfm 70 OF 8♦♦5 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 80/63OF 80/63OF 53/52OF 0 0 Outside Air 235 cfm Supply Fan Cooling Coil 53 / 52 OF 1,780 cfm 43.3% ROOM 75/61 OF _ 75/61 OF A����� i EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 33 of 59 ROOM LOAD SUMMARY Project Name Date Madison Custom Residence 41412018 System Name Floor Area HVAC mstr 1,713 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFM Sensible master Master Bedroom 1 2,012 28,613 2,179 2,012 28,613 2,179 790 30,510 PAGE TOTAL TOTAL' 2,0121 28,6131 2,179 790 30,510 2, 012 28, 613 2,179 790 30,510 Total includes ventilation load for zonal systems. EnergyPro 7.2 by Energ ySoft User Number. 6712 to: Page 34 of 59 I ROOM LOAD SUMMARY Date Madison Custom Residence 41412018 System Name Floor Area HVAC great 1,586 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible great Great Room I 1 1 1,8891 25,4631 1,8891 25,4631 2,018 6931 26,319 PAGE TOTAL TOTAL* 118891 5,463 2,018 693 26,319 1,889 25,463 2,018 693 26,319 * Total includes ventilation load for zonal systems. Ener Pro 7.2 by EnerqySoft User Number: 6712 to: Page 35 of 59 I ROOM LOAD SUMMARY Date Madison Custom Residence 41412018 System Name Floor Area HVAC liv 1,660 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible liv kit Living Kitchen Dining 1 1,8541 24,6591 2,112 1,8541 24,6591 2,112 7621 28,601 PAGE TOTAL TOTAL ' 1,8541 24,6591 2,112 762 28,601 1,8541 24,6591 2,112 762 28,601 Total includes ventilation load for zonal systems. EnenqyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 36 of 59 ROOM LOAD SUMMARY Project Name Date Madison Custom Residence 41412018 HVAC media 1,743 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible media Dining Gallery Media 1 1,624 22,947 1,724 1,624 22,947 1,724 722 27,778 bed3 Bedroom 3 1 376 5,312 494 376 5,312 494 152 5,855 PAGE TOTAL TOTAL' Total includes ventilation load for zonal 2,0001 28,2591 2,2171 874 33,633 2, 000 728,25.91 2,2171 874 33,6331 LEnergyPro 7.2 by EnergySoff User Number: 6712 ID: Page 37 of 59 I ROOM LOAD SUMMARY Madison Custom Residence 41412018 System Name Floor Area HVAC bed 1,580 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible I Latent CFM I Sensible bed 12 Bedroom 1 & 2 1 1 1 1,2731 17,6141 2,010 1,273 17,6141 2,010 5521 21,117 PAGE TOTAL TOTAL' 11 1,27311 7,614 2,010 552 21,117 1,273 17,614 2,010 552 21,117 Total includes ventilation load for zonal systems. EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 38 of 59 I ROOM LOAD SUMMARY Date Madison Custom Residence 41412018 System Name Floor Area HVAC gst 661 ROOM LOAD SUMMARY ROOM COOLING PEAK OLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent j]C4FMSen=sibtent CFM Sensible guest Guest Room 2 1 683 11,710 841 11,710 841 296 15,749 PAGE TOTAL TOTAL ' 683 11,710 841 296 15,749 683 11,7101 841 296 15, 749 Total includes ventilation load for zonal systems. EnenqyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 39 of 59 ROOM LOAD SUMMARY Project Name Date Madison Custom Residence 41412018 HVAC gstmn 2,373 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible guest main Guest House 1 1 2,190 33, 055 3, 019 2,190 33, 055 3, 019 915 36, 636 PAGE TOTAL TOTAL* 2,190 33,0551 3,0191 915 36,636 2,190 33,0551 3,0191 915 36,636 * Total includes ventilation load for zonal systems. EnergyPro 7.2 by EnerqySoft User Number.- 6712 to: Page 40 of 59 ROOM LOAD SUMMARY Project Name Date Madison Custom Residence 41412018 System Name Floor Area HVAC Garage 1,281 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible I Latent CFM I Sensible garage Garage 1 1 4151 9,6771 1,630 415 9,6771 1,6301 7171 11,666 PAGE TOTAL TOTAL' 415 9,677 1,630 717 11,666 415 9,677 1,630 717 11,666 Total includes ventilation load for zonal systems. EnergyPro 7.2 by Enei Soft User Number: 6712 ID: Pa ; 41 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,713.00 ft2 Indoor Dry Bulb Temperature 70 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction. Area U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = c = c = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Flat 1,713.0 X 0.0260 44 1,960 R-21 Wall (W21.2x6.16) 2,747.4 X 0.0488 44 5,899 06door.51.22 331.8 X 0.5100 44 7,446 04door..35.23 91.0 X 0.3500 44 1,401 700-02-05-06-07-08wndw.35.23 70.0 X X 0.3500 44 1,078 11 -14 16-19 21-23-29-31 wndw. 49.19 70.0 0.4900 44 1,509 39wndw .49.27 19.8 X 0.4900 44 427 05wndw.46.17 70.0 X X 0.4600 44 1,417 Slab -On -Grade perm = 172.0 0.7300 44 5,525 'R-0 Interior Wall 410.0 X X 0.3560 0 0 X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 1,713 X Area Ceiling another room 11.00 X 0.262 Height ACH Page Total / 60 J X AT 26,661 _ 3,848 TOTAL HOURLY HEAT LOSS FOR ROOM 30,510 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 42 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room Floor Area 1,586.00 ftZ Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT °F Btu/hr = 1,814 = 4,043 = 2,222 = 5,217 = 1,232 c 5,305 = 2,923 = 0 = = = = = = = = = = = = = = = = = = 22,756 44 = 3,563 R-38 Roof Flat 1,586.0 0.0260 44 R-21 Wall (W.21.2x6.16) 1,882.8 0.0488 44 23-24-26-27-28-32-36-37-38window..35.25 144.3 0.3500 44 01 door . 51.22 232.5 0.5100 44 700-02-05-06-07-08wndw.35.23 80.0 0.3500 44 07door.51.22 236.4 0.5100 44 Slab -On -Grade perim = 91.0 0.7300 44 'R-0 Interior Wall 382.0 0.3560 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,586 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 ] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 26,319 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 43 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Kitchen Dining Floor Area 1,660.00 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F c = = = = 0 = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Flat 1,660.0 0.0260 44 1,899 R-21 Wall (W.21.2x6.16) 2,296.1 0.0488 44 4,930 700-02-05-06-07-08wndw.35.23 93.4 0.3500 44 1,438 08door .51.22 274.5 0.5100 44 6,160 9 door .46.17 162.0 0.4700 44 3,350 09 door..51.22 100.0 0.5100 44 2,244 Slab -On -Grade perim = 151.0 0.7300 44 4,850 'R-0 Interior Wall 410.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,660 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 J X AT 24,871 = 3,729 TOTAL HOURLY HEAT LOSS FOR ROOM 28,601 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 44 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining Gallery Media Floor Area 1,355.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF _ 0 = c c 0 c c _ = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Flat 1,355.0 0.0260 44 1,550 R-21 Wall (W21.2x6.16) 1,817.0 0.0488 44 3,901 700-02-05-06-07-08wndw.35.23 80.0 0.3500 44 1,232 11 door - .46.17 160.0 0.4600 44 3,238 23-24-26-27-28-32-36-37-38window..35.25 329.0 0.3500 44 5,067 21door.49.19 160.0 0.4900 44 3,450 Slab -On -Grade perim = 196.0 0.7300 44 6,296 'R-0 Interior Wall 410.0 0.3560 0 0 'R-13 Wall 76.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,355 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 ] X AT 24,734 = 3,044 TOTAL HOURLY HEAT LOSS FOR ROOM 27,778 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 45 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 Floor Area 388.00 ft2 Indoor Dry Bulb Temperature 70 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Flat 388.0 0,0260 44 444 R-21 Wall (W.21.2x6.16) 274.5 0.0488 44 589 11 -14 16-19 21-23-29-31wndw.49.19 80.0 0.4900 44 1,725 11-12-13-14-16-17-18-19-21-22-29-30-31wndw 48.0 0.4900 44 1,035 09wndw .49.19 13.5 0.4900 44 291 Slab -On -Grade perim = 28.0 0.7300 44 899 'R-0 Interior Wall 366.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 388 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 J X AT 4,983 = 872 TOTAL HOURLY HEAT LOSS FOR ROOM 5,855 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 46 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 1 & 2 Floor Area 1,580.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F 44 = Btu/hr R-38 Roof Flat 1,580.0 0.0260 1,808 R-21 Wall (W21.2x6.16) 2,937.0 0.0488 44 _ _ 6,306 11-12-13-14-16-17-18-19-21-22-29-30-31wndw 93.0 0.4900 44 2,005 dual tint Metal .... 321..25 30.0 0.3200 44 c = 422 Wood Door 24.0 0.5000 44 528 13-21 wndw ..46.17 48.0 0.4600 44 0 972 11 -14 16-19 21-23-29-31wndw .49.19 15.0 0.4900 44 = = 323 Slab -On -Grade perim = 162.0 0.7300 44 5,203 'R-0 Interior Wall 410.0 0.3560 0 _ 0 'R-13 Wall 172.0 0.1020 0 _ 0 = = = = = = = = = = = = = = = = = = Page Total / 60 J X 44 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,580 X Area another room 11.00 X 0.262 Height ACH F 17,567 _ 3,550 TOTAL HOURLY HEAT LOSS FOR ROOM 21,117 EnergyPro 7.2 by EnergySoft User Number- 6712 ID: Page 47 of 59 ROOM HEATING PEAK LOADS Project Name 741412018 Madison Custom Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Room 2 Floor Area 661.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = _ = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Flat 661.0 0.0260 44 756 R-21 Wall (W21.2x6.16) 1,573.5 0.0488 44 3,378 11-12-13-14-16-17-18-19-21-22-29-30-31wndw 268.5 0.4900 44 5,789 21door.49.19 30.0 0.4900 44 647 Slab -On -Grade perim = 115.0 0.7300 44 3,694 'R-0 Interior Wall 288.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 661 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 ] X AT 14,264 = 1,485 TOTAL HOURLY HEAT LOSS FOR ROOM 15,749 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 48 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest House 1 Floor Area 2,373.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = c = c = = = = = = = = = = = = = = = = 44 Btu/hr R-38Roof Flat 2,373.0 0.0260 44 2,715 R-21 Wall (W 21.2x6.16) 3,914.0 0.0488 44 8,404 12-22-26-27.51.22 263.0 0.5100 44 5,902 11-12-13-14-16-17-18-19-21-22-29-30-31wndw 60.0 0.4900 44 1,294 23wndw.49.17 95.0 0.4900 44 2,048 23-24-26-27-28-32-36-37-38window..35.25 126.0 0.3500 44 1,940 26 27dfoor.49.19 60.0 0.4900 44 1,294 Slab -On -Grade perim = 240.0 0.7300 44 7,709 'R-0 Interior Wall 455.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,373 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 ] X AT 31,305 _ 5,331 TOTAL HOURLY HEAT LOSS FOR ROOM 36,636 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 49 of 59 ROOM HEATING PEAK LOADS Project Name Madison Custom Residence Date 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Floor Area 1,281.00 ft2 Indoor Dry Bulb Temperature 70 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = _ = c = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Flat 1,281.0 0.0260 44 1,465 R-21 Wall (W.21.2x6.16) 432.0 0.0488 44 928 Insulated Garage Door 288.0 0.0788 44 999 Slab -On -Grade pen .m = 168.0 0.7300 44 5,396 'R-13 Wall 248.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,281 X Area another room 11.00 X 0.262 Height ACH Page Total / 60 J X AT 8,788 = 2,878 TOTAL HOURLY HEAT LOSS FOR ROOM 11,666 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 50 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 4/4/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,713.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF Ooaaue Surfaces R-38 Roof Flat R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) -R-0 Interior Wall Orientation (E) (N) (E) (S) (W) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = c = = = = = = = 1,713.0 0.0260 56.0 464.1 0.0488 25.7 630.0 0.0488 32.1 859.2 0.0488 28.2 794.1 0.0488 31.8 410.0 0.3560 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnPctratinn 06d 04d 05d 02 04 39 02 06d 05 Orientation (N) (S) (S) (S) (S) (S) (W) (W) (W) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X- GLF = = = = = = = = 0.0 18.4 165.9 21.5 0.0 15.5 91.0 17.9 0.0 15.5 30.0 17.9 0.0 15.5 40.0 17.9 0.0 16.9 30.0 18.8 0.0 19.8 19.8 22.6 0.0 16.9 40.0 25.8 0.0 18.4 165.9 28.8 0.0 15.5 70.0 Page Total Btu/hr 2, 494 581 987 1,183 1,231 6,477 Btu/hr 3,568 1,631 538 717 565 448 1,033 4, 772 1, 648 Internal Gain Btu/hr Occupants 51 Occupants X 245 Btuh/occ. = 1,259 Equipment 1,713 Floor Area X 0.50 w/sgft = 2,923 Infiltration: 1.064 X 0.89 X 86.35 X 37 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28. 113 Latent Gain Btu/hr Occupants 51 Occupants X 155 Btuh/occ. = 797 Infiltration: 4,771 X 0.89 X 86.35 X 0.00376 = 1,383 Air Sensible CFM ELA pW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 797 Number: 671 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 1 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room Outdoor Dry Bulb Temperature 112 OF Floor Area 1,586.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Flat (E) 1,586.0 X 0.0260 X 56.0 = 2,309 R-21 Wall (W 21.2x6.16) (N) 291.9 X 0.0488 X 25.7 = 366 R-21 Wall (W 21.2x6.16) (E) 565.5 X 0.0488 X 32.1 = 886 R-21 Wall (W 21.2x6.16) (S) 463.8 X 0.0488 X 28.2 = 639 R-21 Wall (W 21.2x6.16) (W) 561.6 X 0.0488 X 31.8 = 871 'R-0 Interior Wall 382.0 X 0.3560 X 0.0 = 0 X X = X X = X X = Page Total 5,070 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 36 (N) 0.0 X 15.5 + 98.1 X 18.8 = 1,846 01d (E) 232.5 X 18.4 + 0.0 X 30.5 = 4,270 00 (S) 80.0 X 15.5 + 0.0 X 17.9 = 1,243 38 (S) 0.0 X 15.5 + 23.1 X 17.9 = 414 37 (S) 0.0 X 15.5 + 23.1 X 17.9 = 414 07d (W) 122.7 X 18.4 + 113.7 X 28.8 = 5,524 X + X = X + X = X +1 X = Page Total 13,711 Internal Gain Btu/hr Occupants 48 Occupants X 245 Btuh/occ. =LA Equipment 1,586 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 0.89 X 79.95 X 37 = 2,810 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,463 Latent Gain Btu/hr Occupants 4.8 Occupants X 155 Btuh/occ. = 737 Infiltration: 4,771 X 0.89 X 79.95 X 0.00376 = 1,280 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 737 Ener.QvPro 7.2 by EnerqySoft User Number: 6712 ID: Page 52 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Kitchen Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 1,660.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr R-38 Roof Flat (E) 1,660.0 X 0.0260 X 56.0 = 2,417 R-21 Wall (W 21.2x6.16) (N) 986.6 X 0.0488 X 25.7 = 1,236 R-21 Wall (W 21.2x6.16) (E) 288.0 X 0.0488 X 32.1 = 451 R-21 Wall (W 21.2x6.16) (S) 400.5 X 0.0488 X 28.2 = 552 R-21 Wall (W 21.2x6.16) (W) 621.0 X 0.0488 X 31.8 = 963 'R-0 Interior Wall 410.0 X 0.3560 X 0.0 = 0 X X = X X = X X Page Total 5,618 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 06 (N) 0.0 X 15.5 + 37.4 X 18.8 = 704 07 (N) 0.0 X 15.5 + 56.0 X 18.8 = 1,054 08d (S) 159.5 X 18.4 + 0.0 X 20.6 = 2,929 09d (S) 162.0 X 15.7 + 0.0 X 17.5 = 2,545 08d (W) 70.4 X 18.4 + 44.6 X 28.8 = 2,576 09d (W) 61.2 X 18.4 + 38.8 X 28.8 = 2,240 X + X = X + X = X + X = Page Total 12,047 Internal Gain Btulhr Occupants 5 0 Occupants X 245 Btuh/occ. = 1,220 Equipment 1,660 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.89 X 83.68 X 37 = 2,941 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,659 Latent Gain Btu/hr Occupants 5.0 Occupants X 155 Btuh/occ. = 772 Infiltration: 4,771 X 0.89 X 83.68 X 0.00376 = 1,340 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 772 EnerqvPro 7.2 by EnerqySoft User Number: 6712 ID: Page 53 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 1 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining Gallery Media Outdoor Dry Bulb Temperature 112 OF Floor Area 1,355.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Flat (E) 1,355.0 X 0.0260 X 56.0 = 1,973 R-21 Wall (W 21.2x6.16) (N) 660.0 X 0.0488 X 25.7 = 827 R-21 Wall (W 21.2x6.16) (E) 288.0 X 0.0488 X 32.1 = 451 R-21 Wall (W.21.2x6.16) (S) 581.0 X 0.0488 X 28.2 = 800 R-21 Wall (W.21.2x6.16) (W) 288.0 X 0.0488 X 31.8 = 446 'R-0 Interior Wall 410.0 X 0.3560 X 0.0 = 0 `R-13 Wall 76.0 X 0.1020 X 0.0 = 0 X X X X = Page Total 4,497 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 08 (N) 0.0 X 15.5 + 80.0 X 18.8 = 1,506 11d (N) 0.0 X 15.5 + 160.0 X 17.9 = 2,870 23 (S) 95.0 X 15.5 + 0.0 X 17.9 = 1,476 22d (S) 160.0 X 16.9 + 0.0 X 18.8 = 2,696 24 (S) 0.01 X 15.5 + 78.0 X 17.9 = 1,398 26 (S) 0.0 X 15.5 + 78.0 X 17.9 = 1,398 27 (S) 0.0 X 15.5 + 78.0 X 17.9 = 1,398 X + X = X + X = Page Total 12,740 Internal Gain Btu/hr Occupants 4.1 Occupants X 245 Btuh/occ. = 996 Equipment 1,355 Floor Area X 0.50 w/sgft = 2,312 Infiltration: 1.064 X 0.89 X 68.31 X 37 = 2,401 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,947 Latent Gain Btulhr Occupants 4.1 Occupants X 155 Btuh/occ. = 630 Infiltration: 4,771 X 0.89 X 68.31 X 0.00376 = 1,094 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 630 Enet�qyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 54 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 1 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 388.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Flat (E) 388.0 X 0.0260 X 56.0 = 565 R-21 Wall (W21.2x6.16) (N) 274.5 X 0.0488 X 25.7 = 344 'R-0 Interior Wall 366.0 X 0.3560 X 0.0 = 0 X X X X = X X = X X = X X = X X = Page Total 909 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 08 (N) 0.0 X 16.9 + 80.0 X 19.6 = 1,565 11 (N) 0.0 X 16.9 + 48.0 X 19.6 = 939 09 (N) 0.0 X 16.9 + 13.5 X 19.6 = 264 X + X - X + X = X + X = X + X = X + X = X + X = Page Total 2,769 Internal Gain Btu/hr Occupants 12 Occupants X 245 Btuh/occ. = 285 Equipment 388 Floor Area X 0.50 w/sgft = 662 Infiltration: 1.064 X 0.89 X 19.56 X 37 = 687 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,312 Latent Gain Btu/hr Occupants 1.2 Occupants X 155 Btuh/occ. = 180 Infiltration: 4,771 X 0.89 X 19.56 X 0.00376 = 313 Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 180 EnergyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 55 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name 741412018 ate Madison Custom Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,580.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF ODaaue Surfaces R-38 Roof Flat R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) Wood Door R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) 'R-0 Interior Wall 'R-13 Wall Orientation (E) (N) (NE) (SE) (SE) (SW) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 1,580.0 0.0260 56.0 480.0 0.0488 25.7 793.0 0.0488 29.4 856.0 0.0488 30.4 24.0 0.5000 30.4 520.0 0.0488 31.2 288.0 0.0488 31.8 410.0 0.3560 0.0 172.0 0.10201 0.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 12 13 14 12d 16 21 22 unentation (N) (NE) (NE) (NE) (NE) (SW) (S M Page Total Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X I X GLF = = = = = = = = 0.0 16.9 36.0 19.6 0.0 16.9 15.0 23.5 0.0 16.9 21.0 23.5 0.0 15.7 30.0 24.5 0.0 16.9 21.0 23.5 0.0 15.5 48.0 19.6 0.0 16.9 15.0 21.4 I= Page Total Btu/hr 2,300 601 1,139 1,272 365 792 446 0 0 6,917 Btu/hr 704 353 494 734 494 939 321 1 4,0401 Internal Gain Btu/hr Occupants 4.7 Occupants X 245 Btuh/occ. = 1,161 Equipment 1,580 Floor Area X 0.50 w/sgft = 2,696 Infiltration: 1.064 X 0.89 X 79.65 X 37 = 2,799 Air Sensible CFM ELA AT [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,6141 Latent Gain Btu/hr Occupants 4 7 Occupants X 155 Btuh/occ. = 735 Infiltration: 4,771 X 0.89 X 79.65 X 0.00376 = 1,275 Air Sensible CFM ELA OW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 73.5 User Number: 6712 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 1 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Room 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 661.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr R-38 Roof Flat (E) 661.0 X 0.0260 X 56.0 = 962 R-21 Wall (W 21.2x6.16) (NE) 528.0 X 0.0488 X 29.4 = 759 R-21 Wall (W 21.2x6.16) (SE) 433.0 X 0.0488 X 30.4 = 643 R-21 Wall (W 21.2x6.16) (S W) 354.5 X 0.0488 X 31.2 = 540 R-21 Wall (W 21.2x6.16) (NW) 258.0 X 0.0488 X 29.9 = 377 'R-0 Interior Wall 288.0 X 0.3560 X 0.0 = 0 X X = X X = X I X = Page Total 3,281 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 17 (SE) 0.0 X 16.9 + 80.0 X 20.7 = 1,659 18 (SE) 0.0 X 16.9 + 15.0 X 20.7 = 311 19 ISM 80.0 X 16.9 + 0.0 X 21.4 = 1,348 21 (SW) 80.0 X 16.9 + 0.0 X 21.4 = 1,348 22 (SW) 0.01 X 16.9 + 13.5 X 21.4 = 289 21 d (NW) 0.0 X 16.9 + 30.0 X 23.0 = 689 X + X = X + X = X + X = Page Total 5,644 Internal Gain Btu/hr Occupants 2 0 Occupants X 245 Btuh/occ. =LA Equipment 661 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 0.89 X 33.32 X 37 = 1,171 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,710 Latent Gain Btu/hr Occupants 2 0 Occupants X 155 Btuh/occ. = 307 Infiltration: 4,771 X 0.89 X 33.32 X 0.00376 = 533 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 307 Ener Pro 7.2 by EnerqySdft User Number: 6712 to: Page 57 of 59 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest House 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 2,373.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF Ooaaue Surfaces R-38 Roof Flat R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) 'R-0 Interior Wall Orientation (E) (N) (NE) (E) (SE) (S) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 2,373.0 0.0260 56.0 737.0 0.0488 25.7 630.0 0.0488 29.4 288.0 0.0488 32.1 630.0 0,0488 30.4 912.0 0.0488 28.2 717.0 0.0488 31.8 455.0 0.3560 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenpctratinn 26d 30 23 28 29 31 26d 27d 32 Internal Gain Orientation (N) (N) (N) (S) (S) (S) (W) (W) (W) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.01 18.4 128.0 21.5 0.0 16.9 30.0 19.6 0.0 16.1 95.0 18.5 0.0 15.5 48.0 17.9 0.0 16.9 15.0 18.8 0.0 16.9 15.0 .18.8 0.0 16.9 60.0 25.8 0.0 18.4 135.0 28.8 0.0 15.5 78.0 Page Total nts 71 Occupants X 245 Btuh/occ. _ ent 2,373 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 0.89 X 119.63 X 37 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 7.1 Occupants X 1 155 Btuh/occ. _ Infiltration: 4,771 X 0.89 X 119.63 X 0.00376 = Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7. Btulhr 3,455 923 905 451 936 1,256 1,112 0 9,038 Btulhr 2,753 587 1,761 860 282 282 1,550 3,883 2,0601 14,019 Btu/hr 1,744 4,050 4,204 33,055 Btu/hr 1,103 1,915 1,103 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Custom Residence 1 41412018 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Outdoor Dry Bulb Temperature 112OF Floor Area 1,281.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Flat (E) 1,281.0 X 0.0260 X 77.0 = 2,565 R-21 Wall (W 21.2x6.16) (NE) 137.0 X 0.0488 X 35.1 = 235 Insulated Garage Door (NE) 288.0 X 0.0788 X 37.2 = 845 R-21 Wall (W 21.2x6.16) (SE) 190.0 X 0.0488 X 42.4 = 394 R-21 Wall (W.21.2x6.16) (NW) 105.0 X 0.0488 X 47.3 = 242 'R-13 Wall 248.0 X 0.1020 X 0.0 = 0 X X = X X = X X = Page Total 4,280 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 0 Internal Gain Btulhr Occupants 3.8 Occupants X 245 Btuh/occ. = 942 Equipment 1,281 Floor Area X 0.50 w/sgft = 2,186 Infiltration: 1.064 X 0.89 X 64.58 X 37 = 2,269 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,677 Latent Gain Btu/hr Occupants 3 8 Occupants X 155 Btuh/occ. = 596 Infiltration: 4,771 X 0.89 X 64.58 X 0.00376 — 1,034 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 596 EnerqyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 59 of 59 i 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 1913-Hayer=l6.ribdx CFI R-PRF-01 Page 1 of 16 GENERAL INFORMATION 01 Project•Name Madison Custom Residence 02 Calculation Description Title 24 Analysis 03 Project Location Lot 19B - Madison Club 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07, Compliance Manager Version BEMCmpMgr2013-4b (433) 08 Climate Zone CZ15 09 Software Version, EnergyPro 6.8 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 110 12 Project Scope Newly Constructed 13 Number of Dwelling Units; 1 14 Total Cond. Floor Area (ft2) 12597 15 Number of Zones 9 16 Slab Area (ft2) 12597 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area4(ft) N/A 21 Glazing Percentage (%) 31.2% COMPLIANCE RESULTS 01 Building-Complieswtth_ComputeriPerformance .�. . 02 re* s t 1 '9`i $' t wa ' M*1 *If ya ow pride This building incorporatessfeature-s that require field'testingc dldlorverification,by a certified• HERS rater. under the supervision of a CEC-approved HERS provider. . a ,N - M s , 03 - �,�w .- -�°� ems. .•.,— .�..� -�-� .a,.ri,....... This building incorporates:one or i;ore Special Fea�tures�shhown below This c mplianc naly isis s i valid only foryperm'it pplication°s'through-D°ecemberr3-1, 2016 ENERGY USE SUMMARY 04 ` 05 06 07 08 Energy Use (kTDVIft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 5'.49 7.74 -2.25 -41,00X6 Space Cooling 96.52 85.93 10.59 IAQ Ventilation 0.74 0.74 0.00 0.0% Water Heating: 2.03 2.26 -0.23 -11.3% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 104.78 96.67 8.11 7.7% 19. Al R E E I V E MR mu) Registration Number: 216-No215783G-000000000-0000 CA Building FRA. y I ffilienylandards - 2013 Residential Compliance Registration Date/Time: 2018-03-01 10:56:17 Report Version - CF1R-01212016-433 HERS Provider: CalCERTS inc. Report Generated at: 2018-03-0110:45:27 CITY OF LA Quwn CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 19B-Hayer-16.ribdx REQUIRED SPECIAL FEATURES " The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window. overhangs and/or fins ' CF1 R=PRF-01 Page 2 of 16 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC•Distribution System Verifications: • Duct Sealing .° ,"' •. • Verified low -leakage ducts entirely'in conditioned space Domestic Hot'Water System Verifications:. —.None -. <..if ° k .. VA .BY'- 0 - eat t1k 6'.e 11as %1 24 L:i fu M Wd -A ENERGY DESIGN RATING z- ' x x v� a--. w-+ '' arn, a^. ram. •; . • - a ve. F-- re This is the sum of the annual TDV energy consumptn for energy use omponent ncluded.in theperformance•compliance�approa"ch for the Standard Design Building (Energy Budget) and the annual I TDV energy consumption for lighting and -component s not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use « Yx. Energy DeSign'Rating ' Margin Percent Improvement Total Energy (kTDV/f2-yr)• 137.35 8.11 5.9% . includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Custom Residence 12597 1 10 9 0 1 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 1913-1-layer-16.ribdx CF1R-PRF-01 Page 3 of 16 ZONE INFORMATION 01 02 03 04 05 0.61 ' 07 - Zone Name Zone Type HVAC System Name Zone Floor Area (tt2) Avg. Ceiling Height Water Heating' System 1 Water Heating System 2 master Conditioned HVAC mstrl 1713 11 DHW Sys4 great Conditioned HVAC greaf2. 1586 11 DHW Sys-1 livikit Conditioned HVAC 1iv3 166.0 11 DHW Sys1..1 media Conditioned HVAC media4 1355. 11 _ DHW Sys 1 bed3 Conditioned HVAC media4 388 11 DHW Sys 1 bed 1 2 Conditioned HVAC beds 1580. 11 DHW Sys 1 guest Conditioned `HVAC gst6- 661 11 DHW Sys 1 guest main Conditioned HVAC gstmn7 2373 11 DHW Sys 1 garage Conditioned HVAC`Garage8 1281 11 DHW Sys 1 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD" Project Name: Madison Custom- Residence Calculation,Date/Time: 10:43,7Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison. Lot 19B-Hayer-1'6.ribdx CF1 R-PRF-01 Page 4 of 16 OPAQUE SURFACES 01 02 03 04 05 06 A7 08, Name Zone Construction Azimuth Orientation Gross Area (ft2) Window B.Door Area (ft2) Tilt (deg)'. 20d Wall master R-21 Wall (W.21.2x6.16) 20 Right 630 165.9 90 — 1-10d-Wall-- — — — -- -master — -- —R=21 Walll (W.21.2x6.16) 110 Front 630 90 200d Wall master R-21 Wall (W.21.2x6.16) 200 Left '1010 210.8 90 290d Wall master R-21 Wall. (W.21.2x6.16) 290 Back 1070 215.91 90 Roof master R-38 Roof Flat 1713 20d Wall 2 great R-21 Wall (W.21.2z6.16) 20 Right 390 98:'1 90 110d Wall 2 great R-21 Wall (W.21,.2x6.16) 110 Front 798 232.46 90 200d Wall 2 great R-21 Wall (W.21.2x6.16) 200 Left 590 126.2 90 290d Wall 2 great R-21 Wall (W.21.2x6.16) 290 Back 798 236.412 90 Roof 2 `" great R-38.Roof Flat 1586 20d Wall 3 liv kit R-21 Wall (W.21.2x6.16) 20 Right 1080 93.408 90 110d Wall 3 liv kit ,•.<' R-21 Wall (W:21.2x6.16) 110 Front 288 90. 200d Wall 3 Iry kit,'' Rp21eWaIIT(Wr21:2x6 16) # l�f`"0 _Left _ 722 321.53 90 290dWall 3 Roof 3 t` Iiv kiK - T_� 10 mow. .R2Walf(N%:21�2x6�1"Ei) F� - -yS F4 <_, - R`88=Roof Flag ' `"290 kd f " Back+ TFi 836 1660 214.99 90 20d Will 4- media` H E R`-2n1 Wall:(W.21 _2z6.16)1 ( J r20 I L) Right 1 900 240 90 110d Wall 4 media R-21 Wall (W.21.2x6.16) 110 Front 288 'go 200d Wall 4 media R-21 Wall (W.21.2x6:16) _ 200 Left 1070 489 90 290d Wall 4 media R-21 Wall (W.21.2x6.16) 290' Back 288 90 Roof 4.. media ' R-38�Roof Flat 1355 20d Wall 5 bed3 R-21 Wall (W.21.2x(i.16) 20 Right 416 141.5 9.0 Roof 5 bed3 R-38 Roof Flat 388 20d Wall 6 bed 1 2 R-21 Wall (W.21.2x6.16) 20 Right 516 36 90 50d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 50 - specify ; 880 87 '90 140d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 140 - specify - 860 24- '.90 230d Wall bed 1. 2 R-21 Wall (W.21.2x6.16) 230 - specify - 583 63 90 290d Wall 5 bed 1 2 R-21 Wall (W.21.2x6.16) 290 Back 288 90 Roof 6 bed 1 2 R-38 Roof Flat 1580 50d Wall 2 guest R-21 Wall (W.21.2x6.16) 50 specify - 528 90 140d Wall 2 guest R-21 Wall (W.21.2x6.16) 140 -specify - 528 95 90 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01.10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD. Project Name: Madison Custom: Residence Calculation Date./Time: 10:43, Thu, Mar 01, 2018. Calculation Description: Title 24 Analysis Input File Name: Madison Lot 19B-Hayer-16.ribdx CF1 R-PRF-01 Page 5. of 16 230d Wall 2 guest R-21 Wall (W.21.2x6.16) 230 - specify - 526 173.5 90 320d Wall guest R-21 WaIC(W.21.2x6.16) 320 - specify - y 288 30 90 Roof 7 guest R-38 Roof Flat 661 20d Wall 7 guest main R-21 Wall (W.21.2x6.16) 20 Right 990 253 90 _ 50d Wall.3_— --_- _ _ _.. __ _guest -main- - - - - -—R-21-Wall `(W.21.2x6:.16)" - "- `-50— - - - specify - 630 90 110d Wall 5 guest main R-21 Wall (W.21.2x6.16) 110 Front .288 90 140d Wall 3 guest main R-21 Wall (W.21.2x6.16) 140 - specify - 630 90 200d Wall 5 guest main R-21 Wall (W.21:2x6.16) 200 Left 990 78 _ 90 290d Wall 6 guest main R-21,Wall (W.21L2x6.16) 290 Back 990 273 90 Roof 8 guest main R-38.Roof'Flat 2373 50d Wall 4 garage R-21 Wall (W.21.2x6.16) 50 specify - 425 288 90 140d Wall'4 garage R-21 Wall (W.21.2x6.16) 140 - specify - 190 90 320d Wall 2 garage R-21 Wall (W.21.2x6.16) 320 ' -specify - 105 90 Roof 9 garage R-38 Roof Flat 1281' ATTIC' > 41 I �' r 01 02 , : d'... r 03 04 gg _ 00 1 1 06, 07 08 Name Construction° -.arw .ire Type. _ _ .rw�+y�R �a �n sc Roof Rise _ a-• re s.� ems- """Roof Reflectance 'W w Roof:Emittance Radiant Barrier., Cool Roof Attic master Attic*Roofmaster i MentllatedM -':)P V' (5-1 kJ V 10.62.0 C M 0:81 Yes Yes Attic great Attic Roofgreat . Ventilated 0 0.62 0.81 Yes Yes Attic liv kit Attic Roofliv kit' Ventilated 0 . 0.62 .0.81 Yes Yes Attic media Attic Roofinedia Ventilated" 0 0:62 0.81 Yes Yes Attic bed3 Attic Roofbed3 Ventilated 0 0.62 0.81 Yes Yes Attic bed 1 2 Attic Roofbed 1 2 Ventilated 0 0.62 6.81 Yes Yes .: Attic guest Attic Roofguest Ventilated 0 0.62 0.81 Yes Yes - Attic guest main Attic Roofguest main Ventilated 0 6.62 , 0.81 Yes Yes l Attic garage Attic Roofgarage Ventilated 0 0.62 0.81 Yes Yes Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Description: Title 24 Analysis. Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Input File Name: Madison Lot 19B-Hayer-16.ribdx CF1 R-PRF-01 Page 6 of 16 WINDOWS 01 02 03 04 05 06 07 08 09, 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U-factor SHGC Exterior Shading 06d Window 20d Wall (Right-20) _ -- -- 1 165.9 0.51 0.22 Insect Screen (default) 04d Window 200d Wall (Left-200) -- -- 1 91.0 0.35 0.23 Insect Screen (default) 05d Window 200d Wall (Left-200) -- -- 1 30.0 0.35 0.23 Insect Screen (default) 02 Window 200d Wall (Left-200) -- -- 1 40.0 0.35 0.23 Insect Screen (default) . . 04 Window 200d Wall (Left-200) -- -- 1 30:0 0.49 0.19 Insect Screen (default) 39 Window 200d •Wall (Left-200) '• =- -- 1 19.8- 0.49 0.27' Insect Screen (default) 022 Window 290d Wall (Back-290) -- - 1 40.0 0.49 0.19 , Insect Screen (default) 06d 2 Window 290d Wall (Back-290) -- - 1 165.9 0.51 0r22 Insect Screen (default) 05 Window 290d Wall (Back-290) -- -- 1 70.0 . 0.46 _ 0.17 Insect Screen (default) 36 Window 20d Wall (Right-20) -- -- 1 98.1 0.35 0.23 Insect Screen (default) 01d Window. `^ 110d Wall 2_(F,ront-110) 19.7 11.8 1 232.5 0.51� 0.22 Insect Screen (default) 00. Window -200d Wall,2 (Left-200) 8 Opp 10.0 1 80.0 0.35 0.23 Insect Screen (default) 38 Window 200d Wall 2 ( eft-266) ° 1 Pk23.1 .0.35 0.23 Insect Screen default 37• Window 200a:Wall;2r(Left"200) -wnitii _ �3 M ` Fi 1 623:1 M Yef 6.35 0.23 Insect'Screen (default) 07d Window\290d Wall 2 (Bay -290) 19r7 11�:8 1.017 , �236.4 0.51 0.22 Insect Screen (default) 06 Window 20d Walla (Right-20) 8A V 770 0.668 • -37.4 0.35 0.23 Insect Screen (default) 07 Window 20d Wall 3 (Right-20) . 8.0 7.0 1 56.0 0.35 0.23 Insect Screen (default) 08d Window 200d Will 3 (Left-200) 14.5 11.0 1 159.5 0.51 0.22 Insect Screen (default) .09d Window ' 200d Wall 3 (Left-200) 16.5 10.0 0.982 162.0 0.47- 0.17 Insect�Screen (default) 08d•2 Window 290d Wall 3 (Back-290) 11.5 10.0 1 115.0 0.51 0.22 Insect Screen (default) 09d 2 Window 290d Wall 3 (Back-290) 11.0 16.0 0.909 100.0 0.51 0.22 Insect Screen- (default) 08 Window 20d Wall 4 (Right-20) 8.0 10.0 1 80.0 0.35 0.23 Insect Screen (default) 11d Window 20d Wall 4 (Right-20) 16.0 10.0 1 160:0 0.46 0.17 Insect Screen (default) 23 Window 200d Wall 4 (Left-200) 9.5 10.0 1 , 95.0 0.35 0.23 Insect Screen (default) 22d Window 200d Wall 4 (Left-200) 16.0 10.0 1 160.0 0.49 0.19 Insect Screen (default) 24 Window 200d Wall 4 (Left-200) - - 1: 78.0 *0.35 0.23 Insect Screen (default) 26 Window 200d Wall 4 (Left-200) -- -- 11 78.0 0.35 0.23 Insect Screen (default) 27 Window 200d Wall 4 (Left-200) -- -- 1 78.0 0.35 0.23 Insect Screen (default) 082 Window 20d Wall 5 (Right-20) 8.0 10.0 1 80.0 0.49 0.19 Insect Screen (default) Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project.Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 19B-Hayer-16.ribdx CF1 R-PRF-01 Page 7 of 16 11 Window, 20d Wall 5 (Right-20) 8.0 6.0 1 48.0 - 0.49 0 19 Insect Screen (default) 09 Window 20d Wall.5 (Right-20) -- -- 1 13.5 0.49 0.19 Insect Screen -(default) 12 Window 20.d Wall 6. (Right20) - -- 1 36,0. ' 0.49= 0.19 Insect Screen (default) 13 Window 50d Wall (- specify -50) - - 1 15:0 0.49 0.19 Insect Screen (default) 14 Window 50d Wall (- specify -50) -- -- 1 21.0 0.49 1 0.19 Insect Screen (default) 12d Window 50d Wall (- specify -50) -- -- 1 30.0 0.32 0.25 Insect Screen'( default) 16 Window 500 Wall (- specify -50).. -- -- 1 21.0 0.49 0.19 Insect Screen (default) 21 Window 230d Wall (- specify -230) -- -- 1 48.0 0.46 0.17 Insect Screen (default) 22 Window 230d Wall'(- specify -230) - -- 1 15.0 0.49 0.19 Insect Screen (default) 17 Window 140d Wall 2 (- specify -140) -- -- 1 80.0 0.49 0.19 Insect Screen (default) 18 Window 140d Wall 2 (- specify -140) -- -- 1 15.0 0.49 0.19 Insect Screen (default) 19 Window 230d Wall 2 (- specify -230) -- -- 1 80.0 0.49 6.19 Insect,Screen (default) 21 2 Window 230d Wall 2 (- specify -230) -- - 1 80.0 0.49 0.19 Insect Screen (default) 222 Window 230d Wall 2 (- specify -230) -- -- 1 13.5 0.49 10.19 Insect Screen (default) 21d Window ` , = 320d Wall (- specify-320) -- - 1 30.0 0.49 0.19 Insect Screen (default) 26d Window 20d Wallr.7g(Right 20) �:d a - 1 128.0 0.51 6.22 Insect Screen (default) 30 Window ,' 20d�Wall 7 (R gha-2Q) - 011 1 30.0 ' 0.49 0.19 Insect. Screen (default) 23 2 Window' T 20d Wallx7�(Righf-20) ° j -- SP ;- 1 95?0 0.49 0.17 Insect,Screen (default) 28 Window 200d Wallf�5 (Left-20,0)a P P -f--) t j -R r) k, ::Z48.0 0.35 0.23 " Insect Screen (default) 29 Window 200d Wall 5 (Left-200) -- - 1 15.0 0.49 0.19 Insect Screen (default) 31 Window 200d Wall 5 (Left-200) -- -- 1 15.0 0.49 0.19 Insect Screen (default) 26d 2 Window 290d Wall 6 (Back-290) -- -- 1 .60.0 0.49 0.19 Insect Screen (default) ` 27d' Window 290d Wall 6 (Back-290) -- --- 1 135.0 0.51 0.22 Insect Screen (default) 32 Window 290d Wall 6 (Back-290) -- --- 1 78.0 1 0.35 0.23 1 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 140d Wall 24.0 0.50 Door 2 50d Wall 4 72.0 0.08 Door 3 50d Wall 4 72.0 0.08 Door 4 50d Wall 4 72.0 0.08 Door 5 50d Wall 4 72.0 0.08 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018.03.01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title•24 Analysis Input File Name: Madison Lot 1913-Hayer-16.ribdx CF1 R-PRF-01 Page 6of 16 OVERHANGS AND FINS 01 02 03 04 05 06 07 08, 09 10 11 12 1,13 14 Over"ng Left Fin Right Fin Window Depth "Dist Up Left Extent Right Extent Flap Ht. Depth Top,Up Disti- Bot Up Depth Top -Up Dist R Bot Up 01d 14 0.1- •14 14 0 0 0 0 0 .0 0 0- 0 00 14 0.1 14 14 0 0 0 0 0 0 0 0 0 07d 14 0.1 14 14 0 0, 0 0 0 0 0 0- 0 06 12 0.1 12 12 0 0 0 0 0 0 0 0 0, 07 12 0.1 12 12 0 0 0 0 0 0` 0 0 .0 08d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 09d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 08d 2 14: 0.1 14 14 0 0 0 0 0 0 0 0 0 09d2 14` 0.1 14 14 0 0 0 0 0 0 0 0 0 08 10 01 .«.'�" 10 10 0 0 0 0 0 0 0 0 0 •' 11d ;`12 "`0.1•.`12sc 0 0 0 zip, �.r 0 0 0.. 0 0 '- 23 12;: '� 0:1% 12 F�2 I3 . 2 ' !�. 0 t 0 0 0� 0 0 U 0 , . ; 0 22d 120:1, 12 _ .0 •sue 12 w ca _0 G! _0. xv: W 0 a � _ 0 �a 0 0 0 0 0 082 12 v01 r',12 t: tl%12w> 1- ("0 V 1 0.� r- d� 0 0 0 0 0 11 12 0.1 12 12 0 0 0 0 0 0 0 0 0 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis, Input.File Name: Madison Lot 19B-Hayer-16:ribdx ' as CF1 R-PRF-01 Page 9 of 16 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06, 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing ' R-value U=value Assembly Layers • 'Cavity / Frame: no insul. / 2z4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck` Wood Siding/sheathing/decking Attic'Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) . • Inside Finish: Gypsum Board Ceilings (below •. Cavity/Frame: R-9.1 /2x4 R-38 Roof Flat attic) Wood Framed Ceiling 2x4 @-16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 •' Exterior Finish:,.Wood .. R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall . 2x6 @ 16 in. O.C. " R 21 0.066 Siding/sheathing/decking • Cavity /. Frame: no insul: / 2x4 Top Chrd 2x4 Top Chord of Roof Truss.@ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgreat Attic Roofs-, Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shing/e) " g Cavity/ Frame: rio insul: / 2x4 Top Chrd x. 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic.Roofliv kit Attic Roofs Wood Fra nedsCeilin „ ,a �. 9 inf O.C. _ > ,aa .none 0:644 Roofing: Light Rdof.:(Aspha/t Shingle): � 2 4 To Chd d of Roof Truss 24 (07�- Cawty/Frame: no insul.`/2x4 Top Chrd Roof Deck. ,Wood Siding/sheathing/decking . Roofinedia Attic644 AtticRoofs" WoodFr m` >"ili a ed Ce ngin. v'""� j` a V@ 4k O:C. Roofing: Light 3 none Roof (Asphalt Shingle) F K U,%/. V , "(a { Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • 'Roof Deck: Wood Siding/sheathing/decking Attic Roofbed3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul: /2x4 Top Chrd 2x4'Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofbed 1 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • . Cavity/ Flame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof. Deck: Wood Siding/sheathing/decking Attic Roofguest Attic Roofs '. Wood Framed Ceiling in: O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck:.Wood Sidi6g/sheat6&decking• Attic Roofguest main Attic Roofs Wood Framed Ceiling in. O.C. none . 0.644 Roofing: Light Roof (Aspha/t.Shing/e) • Cavity/Frame: no-insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgarage Attic Roofs Wood Framed Ceiling in. OL. none 0.644 Roofing: tight Roof (Asphalt Shingle) Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD" CF1R-PRF-01 Project -Name: Madison Custom Residence . Calculation Date/Time: 10'.43, Thu, Mar 01, 2018 Page 10'of 16 Calculation Description: Title 24 Analysis Input File Flame:, Madison Lot 1913-Hayer-16.ribdx y SLAB FLOORS r 01 02 '63 04 65 06 ' ' 07 Name ' " Zone Area (I;I) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction ,: Heated ` Slab '". master 1713 172 None" 0.8 No Stab 2 great 1586 91, None 0.8 No , Slab 3 liv kit 1660 ' 151 None 0.8 No Slab 4 media ` 1355 196 None 0.8 No Slab 5 bed3 388 26 None 0.8 No Slab 6 bed 1 2 1580 -. 162 None 0.8 No Slab 7 guest 661 115 None 0.8 No Slab 8 guest main 237.3 240 None 0.8 'No Slab 9 garage 1281 168 None 0:8 r No BUILDING ;ENVELOPE - HERS'VERIFICATION 01 ' , . 02 03 04 Quality Insulation lnstallation'(QII) - Quatit,�Installationrof $pray,,Foamdnsulattion s BuildinT;Envelope. Air Leakage CFM50 Required �NoRequired NotRequired,, — WATER HEATING SYSTEMS: a 01 02 ` . - - 03 - 04 05 06 Name System Type. Distribution Type Water Heater Number of Heaters . Solar Fraction.(%) DHW Sys 1 - 1/2 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS` 01 02 03 04 .05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description- Title'24 Analysis Input File Name: Madison Lot 1913-Hayer-16.ribdx CFI R-PRF-01 Page 11 of 16 i WATER HEATING - HERS VERIFICATION 01 02 03 04 05, 06 07 Name Pipe Insulation Parallel Piping Compact. Distribution Point -of Use Recirculation Control Central DHW Distribution- DHW Sys 1 - 1/2 — — — — SPACE CONDITIONING SYSTEMS 01 A2 03 04 05 06 ' SC Sys Name System -Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC mstrl Other Heating and Cooling �� System Heating Component 1 Cooling Component 1 _ HVAC Fan 1 Air Distribution System 1 HVAC great2 'Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC liv3 `Other Heating and Cooling 4 System Heating Component 3 Cooling Component 3 HVAC.Fan 3 Air Distribution.System 3 HVAC media4 Other Heatingand Cooling � . s rSyste Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution,System 4 s i i ; tom, wwwa A04 M. HVAC beds. Other Heatingand Cooling i Heating Comp of 5Cooling Co ponent 5 HVAC Fan 5 Air Distribution System'5.'_ c •, FSystem HVAC gst6 a.. wus• �,.. Ot ter:Heating and Cooling: System- Heating�Component 6 ' " Cooling Component 6 HVAC Fan 6 Air Distribution System 6 � � � ` p, • -t$ � I � j �' E HVAC gstmn7 Other Heating and Cooling System Heating Component 7 Cooling Component 7 HVAC Fan 7 Air Distribution System 7 SPACE CONDITIONING SYSTEMS .01 02 0.3 04: 05' 06 SC Sys Name System Type. Heating Unit Name Cooling Unit Name Fan Name Distribution Name :Heat Pump System 8:::2:3 Heat Pump Heating and Cooling System Heat'Pump System 8 Heat Pump System 8 None None Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF. COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE, METHOD CF1R-PRF-01 Project Name: Madison'Custom'Residence Calculation Daterrime: 10:43, Thu, Mar 01, 2018- - Page.:12 of.16. Calculation Description: Title 24 Analysis Input File Name: Madison:Lot 1913-H6yer-16.ribdx 3. HVAC = HEATING UNIT TYPES., 01 4 02 :; ...; Name Type Efficiency. , Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace -Fuel-fired centratfurnace 80 AFUE Heating Component 3 CntrlFumace - Fuel fired central. furnace, 80 AFUE _ Heating Component 4 CntrlFurnace - Fuel fired central furnace -80 AFUE Heating Component 5 CntrlFurnace -. Fuel -fired central furnace 80 AFUE Heating Component 6 Cntrl u'rnace -:Fuel-fired central furnace 80 AFUE Heating Component •T CntrlFurnace - Fuel -fired central furnace ' 80 AFUE = HVAC —HEAT PUMPS;, 02 03 04 05 .06 07 08 09p, 10 Heating` `Cooling Zonally Multi speed HERS< F. Name Type° Cap Cap 17 SEER EER Contolled CmpresrFo Verification. Heat Pump System 8 DuctlessHeatPump 8.3 32000t r19200 � 13.1. ! 1. 11 No No Heat Pump System`" hers ff -. :. {... 8 cool' kill E- E R.S P ROV1:D Registration Number: 216-Nb215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10:43,-Thu, Mar 01, 2018 Calculation -Description: Title 24 Analysis Input File Name: Madison Lot 1'9B-Hayer-16.ribdx CF1 R-PRF-01 Page 13 of 16 HVAC - COOLING.UNIT TXPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification. Cooling Component 1 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 3 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 4 SplitAirCond 13 16 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 5 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component SpltAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 7 SplitAirCond 13 16 Not Zonal Sirigle Speed Cooling Component µ_ 1-hers-cool' DuctlessHeatPmp 1;1 3.1 NotZonal Single Speed Cooling Component 1-her6=cool HVAC COOLING'- HERS VERIFICATION t;'-'H F R c;' P R" 0 € D F R 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool.. Required 350 Required Required Required Cooling Component 27hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Cooling Component 5-hers-cool Required 350 Required Required Required Cooling Component 6-hers-cool Required 350 Required- Required Required Cooling Component 7-hers-cool Required ' " 350 Required Required Required" Heat Pump System 8-hers-cool Not Required Not Required Not Required Required Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 99 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison. Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis InputFile Narne:.Madison Lot 1915-Hayer-16.ribdx CF1 R-PRF-01 Page 14 of 16' HVAC - DISTRIBUTION SYSTEMS 01 02 03 64 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS.Verification Air Distribution System 1 LowLlCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 1-hers-list Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution, System 2-her§-clist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3-hers-list Air Distribution System 4 LowLlCod Sealed -and tested 8 Conditioned zone (VLL) None Air Distributibn System 4-hers-list Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution. System 5-hers-dist Air Distribution System 6 DucfsAttic Sealed and tested 8 Attic None Air Distribution System 6-hers-list .Air Distribution System 7 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 7-hers-dist .sf �L"§f }�. se0.YE4 aplg;d P.i"hM!!Im'A .e�i.M no ducts PV None ' HVAC DISTRIBUTION - HERS VERIFICATION 01 02 � 03r `04 � 1-05 _' _ O6�' 07 08 Name Duct Leakages Verification MDu Le k ge-_> Target (%) Ve`ri1iedrDuc0-_ Location 9 Vehfied Ducts Design � rduried Ducts Deeply Buried Ducts Low -leakage Air Handlei Air Distribution System 1-hers-list Required. 6.0 Required Not Required Not Required Not Required -- Air Distribution System 2-hers-disc. Required 6.0 -Not Required Not Required, Not -Required Not Required -- Air Distribution System 3-hers-dist Required 6.0 r Not Required Not Required Not Required Not Required -- Air Distribution System 4-hers-dist Required.. 6.0 Required Not Required Not Required .Not Required. -- Air Distribution System 5-hers-dist Required 6.0 Not Required Not Required Not Required- Not Required - Air Distribution System 6-hers-list Required 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 7-hers-list Required 6.0 Not Required Not Required Not Required Not.Required — Registration Number: 216-No215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 k CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time:10:43, Thu, Mar 01, 2018 Calculation, Description: Title 24 Analysis Input File Name: Madison Lot 1913-Hayer-16.ribdx CFI R-PRF-01 Page 15 of 16 HVAC - FAN SYSTEMS ' 01 02 w 03 04 Name Type ' "' Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0'.58 HVAC Fan 1-hers-6n HVAC Fan 2 Single Speed-PSC Furnace Fan, 0.58 .HVAC Fan 2-hers-fan HVAC.Fan 3 Single Speed PSC Furnace Fan 0.58 . HVAC:Fan 3-hers-fan . HVAC Fan 4 Single Speed PSC Furnace Fan •0.58 HVAC Fan 4 hers -fan' HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan•5=hers-fan HVAC Fan 6 Single Speed'PSC Furnace Fan 0.58 HVAC Fan 6-hers-fan HVAC Fan 7 Single Speed_PSC'Furnace Fan 0.58 HVAC Fari'7-hers-fa6 ,HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name;? . ,. Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)' HVAC Fan 1-hers-lain .'pow Ftequedy 0.58 HVAC Fan 2=hers fans"" ' " :&Required ., 0:58 HVAC Fari4hers fan r .` Required . ,q .4 • ; 0.58 HVAC Fan 4-hers-6n" . ` j (Z 0 Required X /"I r--S 0.58 HVAC Fan 5-hers-fan _ Required _ W .0.58 HVAC Fan'6-hers-fan Required , • 0.58 HVAC Fan 7-herS7fan Required 0.58 IAQ'(Indoor. Air Quality) FANS ` 01 02 03 04 05 06' ` Dwelling Unit IAQ CFM IAQ Watts/CFM ' IAQ Fan Type IAQ Recovery Effectiveness(%o) HERS Verification SFam IAQVentRpt 208.47 0.25 Default 0 Required Registration Number: - 216-NW1 5783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 4 HERS Provider: • CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE 2 RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 ` Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu,.Mar01, 2018 Page 16 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 1915-Hayer-16.n . x DOCUMENTATION AUTHOR'S,DECLARATION STATEMENT 1. i certify thatthis Certificate of `Compliance documentation•is accurate and complete. DocumentatiomAufhor Name: Documeritation Author Signature: , Tim Scott Company: Signature Date: Scott Design and Title'i24, Inc. 2018-03-01 10.56:17 Address: CEA/HERS Certification' Identification (If applicable): 77685 Michigan Drive City/State/Zip: Phone: . Palm Desert, CA-9221.1 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify `the following under penalty of perjury, undekhe laws.of the State of California: 1. I am eligible under Division 3_of the Business and Professions Code to accept responsibility for the building.design identified on this Certificate of Compliance. 2. I certify that the energy features and performance_ specifications identified on this Certificate of Compliance;conform to the requirements'of Title 24, Part.1 and Part 6 of the California Code of Regulations. 3. The building.design features orsystem-design'features identifiedon•this Certificate of.Compliance are consistent with the information provided on other applicable compliance documents, worksheets; calculations,ptans ands ecifications submiti6-d�o� the enforc�emenj_ncy �for a�pproval with this building permit application. Responsible Designer Name; ;Responsible Designer Signature'1.% Pv Tim Scotty - Company: Date'�SiIt gned: ar 0M1 Scott Design -and Title 24, Inc. 2 10:56:1.77 Address: License:. ' ' 77085 Michigan Drive na ;City/State/Zip: Phone: Palm'Desert, CA 92211 760-200-4780 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: , CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu,,Mar 01; 2018 Page 1 of 16 Calculation Description: Title 24"Analysis Input File Name: Madison Lot 19B-Hayer-16.ribdx GENERAL INFORMATION 01 Project Name Madison Custom Residence 02 Calculation Description Title 24 Analysis 0.3 Project Location Lot 19B - Madison Club 04 City. 'La Quinta 05 Standards.Version Compliance.2015 06 Zip Code 92253 07 Compliance 'Mariager_Veision BEMCmp Mgr 2013 4b (433) 08 Climate Zone CZ-15, •09 Software Version. EnergyPro 6.8 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 110 12 Project.Scope Newly Constructed 13 Numberof Dwelling Units 1 14 Total Cond. Floor Area (ft2) 12597 15 Number of Zones 9' 16 Slab Area (if) ) 12597 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area*1) N/A 21 Glazing -Percentage (%) 31.2% COMPLIANCE RESULTS.. 01 Building Complies with�Computer`Performonce* I 02 This building incorporates'features that require fielditesting and/or verification by'a certified HERS rater under the supervision of a CEC-approved HERS provider. ► t r .a+ �s A rA ... a� 12 t4: 03 This,building.incorporates one orpore Spec*al�Feat�uresovrn�below This compliance naly is i alid only for permit applications*through,December 3 , 2016 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDVlft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 5.49 7.74 -2.25 -41.0% Space Cooling 96.52 85.93 10.59 .11.0% IAQ Ventilation 6.74 0.74 0.00 0.0% Water Heating 2.03 2.26 -0.23. -11.30/6 Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 104.78 96.67 8.11 7.7% Regi straMA R u I lip r:2 RMN0215783G-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance CITY OF LA QUINTA COMMUNITY DEVELOPMENT Registration Date/Time: 2018-03-01 10:56:17 Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project'Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Page 2.of 16. CalculatioriDescription: Title 24 Analysis Input File Name: Madison Lot 1913-Hayer-16.ribdx HERS FEATURE SUMMARY The'following is a°summary ofthefeatures that must be field -verified by a certified HERS Rater as a condition for -meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulationanstallation (Qll) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER -..Verified SEER • ' Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified'low-leakage ducts entirely in:conditioned space Domestic Hot Water System Verifications • -None -- f .• - ,r V1W , Ar-W- w IL V4 a 'A 61 1s •fit a r --.rs�n+ T�-+'iYi L+I; �Yi1Bw� �i.wAW •sir M Gr •nbE!� -i• wli w- T..iW \II ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy usecorilp no ents included in the performance compliancelapproach'for: thr�tandard Design Building (Energy Budget) and the -annual TDV energy corisumption for lighting and components notr.egulated,by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system.. - Reference Energy Use$�Energy ges�gn Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)• 137.35 8.11 5.9% includes calculated Appliances and Miscellaneous Energy. Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 �04 05,. 06 07 Project Name Conditioned Floor Area (ft2) Number.of Dwelling Units-' Numb o edro ms ' ' Number of Zones Number of Ventilation Cooling -Systems Number of Water ` `Heating Systems Madisori Custom Residence 12597 1 10 9 0 1 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 'CEVZTIFICATE:OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation,Date/Time: 10:43, Thu, Mar01,, 2018 Calculation.Desckiption: Title 24 Analysis Input File Name: •Madison Lot 1913-Hayer-16.ribdx. . ZONE;INFORMATION (- _01^ 02 ,. 03: OS'"•. =' . O6,` .. 07 P . Zone Name Zone Type HVAC System Name one loo Area Z F . r. (ft2) Avg Ceiling_ . Height; Water Heating System 1, Water;Heating System 2 master Conditioned HVAC`mstrl 1713 11 pH1N Sys 1 g Conditioned' HVAC'e2 586 11reat s 1g by kif Conditioned. HVAC Irv3,;. _ ".1660 DHW Sys 1: ,..- Condond HVAC medi . DHW Sys 1media 'bed3 Conditoned.'' HVACmeda4 388 1.1:'' DHWSys'U° bed1`2 : Conditioned! HVAC: beds' 1580 11 DHW Sys t°; guest- Conditioned; HVAC gst6 661" 11 DHW Sys 1, guest main Conditioned .. HVAC gstmn7 2373 11 DHW Sys 1 .garage, Conditioned: HVAC.Garage8, 1281 11 DHW Sys 1 HERS PR.:OVVDER.. Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD, Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 19B-Hayer-16.ribdx CF1 R-PRF-01 Page 4 of 16 OPAQUE SURFACES 01 f' - 02 03 04 05 06 07 08 Name Zone. Construction Azimuth Orientation .Gross Area (ftz) Window & Door Area (ft) Tilt (deg) 20d Wall master R-21 Wall (W.21.2x6.16) 26 Right 630 165.9 90 T10d Wall master R-21 Wall (W.21.2x6.16) 110 Front 630 90 2606Wall master R-21 Wall (W:21.2x6.16)" 200 Left 1070 '' 210 8 '" 90- 290d Wall master R-21 Wall (W.21.2x6.16) 290 Back 1070 275.9 90 Roof master R-38 Roof Flat 1713 20d Wall 2 great R-21 Wall (W.21.2x6.16) 20 Right 390 98.1 90 110d Wall 2 great R-21 Wall (W.21.2x6.16) 110 Front 798 232.46 90 200d Wall 2 great R-21 Wall (W.21.2x6.16) 200 Left 590 126.2 90 290d Wall,2 great R-21 Wall (W.21.2x6.16) 290 Back 798 236.412 90 Roof 2. great R=38-Roof.Flat 1586 20d Wall 3 � 0 'liv kit R-21 Wall (W.21.2x6.16) 20 Right 1080 93.408 90 110d Wall.3 liv kit R-21 Wall (yl/ 21:2x6:16) 110 Front 288 90 200d W611 3 7'8 liwkit� R 21~Wa ((W 21 2z6±16) it?U .. " . d �, .� I 200 # Left. ,M.. b 722 321.53 90. 296d Wall 3 liv kw rh5dwaii (W 21:2z6 16j�1, I290 # Ida&) .: 836 . 214.99 90 Roof 3 `4 `�liv kit `t >M R 38fk of�F1'atl U i 44W )f 0 10 V 4P 1660 20d Wall media Rg21 Wall. W.21'27x&19 { 't20' Ri'ht 900 240 90 110d Wall 4 media R41 Wall (W.21.24.16) 110 Front 288 90 200d Wall 4 media R-21 Wall (W.2.1.2x6.16) 200 Left .1070 489 90 290d..Wall-4, media R-21 Wall (W.21.2x6.16) 290 Back . 288 90 Roof 4 a media R-38 Roof Flat 1365 20d Wall 5 bed3 R-21 Wall (W.21.2x6.16) 20 Right 416 141.5 " 90 Roof 5 bed3 R-38 "Roof•Flat 388 20d Wall 6 bed 1 2 R-21 Wall (W.21.2x6.16) 20 -Right 516 36 90 50d Wall bed 1" 2 R-21 Wall (W.21.2x6.16) • .50, - specify - 880 87, 90 140d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 140 specify - 880 24 '90 ' 230d Wall bed 1 2 R-21 Wall (W.21.2x6.16) 2301 -specify - 583 63 .90 290d Wall 5 bed. 1.2 R-21 Wall (W.21.2x6.16) n 290 Back 288. 90 Roof 6 bed.1 2 R-38 Roof Flat 1580 50d Wall 2 guest R-21 Wall (W.21.2x6.16) 50 - specify - 528 90 140d Wall 2 guest R-21 Wall (W.21.2x6.16) 140 specify - 528 95: 90 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01.10:45:27 CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 201:8 Page 5 of.16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 1913=1-layes-16.ribdx 236d Wall 2 guest R-21 Wall (W.21.2x6.16) 230 . specify*'-'' 528 173:5 • 90 326d Wall guest R-21 Will (W.,21.2z6.16) 320 - specify - 288 30 90 Roof.7 guest R-38 Roof Flat 661 20d Wall 7 guest main R-21 Wall (W.21.2x6.16) 20 Right 990 253 90 50d Wall 3 guest main R-21 Wall (W.21.2x6.16), 50 -,specify - 630 90 110d Wall 5 guest main R-21 Wall (W.21.2x6.1.6) 110 Front 288 90 140d Wall 3. guest main R-21 Wall (W.21.2x6.16) 140 specify - 630 90 200d Wall 5 guest main R-21 Wall (W.21.2x6.16) 200. Left 990 78 90 290d Wall 6 guest main R-21 Wall (W.21.2x6.16) 290 Back 990 273 90 Roof 8 guest main R-38 Roof Flat 2373 50d Well 4 garage R-21 Wall (W.21.2x6.16) 50 specify - 425 288 90 140d Wall 4 A,garage R-21 Wall (W.21.2x6.16) 140 specify - 190 90 320d Wall 2 J�garage R-21 Wall (W.21.2x6.16) _ 320 - specify - 105 90 Roof 9 garage R-38 Roof Flat 1281 ATTIC F'0 .sit s R 1 ., .fie 01 r02.a.. AA03" � �- , tip➢ Ott 04 .. -. O l a 06 67 08 Name t..r Construction .-�ww -�;rr v., +a r Type _ w. Roof Rise _ .w 4 r-• .-. �e w.r a,� . Roof Reflectance �; •- c _Roof Erittarice Radiant Barrier Cool Roof Attic master Attic Roofmaster. • `� ► �VentilateiiM 0"A V 0.62J 0.81 Yes Yes Attic great Attic Roofgreat Ventilated ' 0 . 0.62 0.81 Yes Yes Attic liv kit • Attic Roofliv kit Ventilated 0 0.62 • 0.81 Yes . Yes Attic media `; Attic Roofinedia Ventilated 0 0.62 0.81 Yes Yes Attic b"ed3 Attic Rooftied3 Ventilated 0 0.62 0.81 Yes Yes _ Attic bed 12 Attic Roofbed 1 2 Ventilated 0 0.62 0.81 . Yes Yes Attic guest Attic Roofguest Ventilated., 0 0.62 0.81 Yes Yes ' Attic guest main Attic Roofguest main Ventilated 0 0.62 0.81 Yes Yes Attic garage Attic Roofgarage Ventilated 0 0.62 0.81 Yes Yes Registration Number: 216-No215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 C8RTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Page 6 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 1913-Hayer-16.ribdx:,' WINDOWS r' 01 62 03 04 05... 06.. 07 '.08 09 10 Name Type Surface (Orientation -Azimuth) - Width (ft) Height (ft) Multipli er • Area (ft) U-factor. SHGC Exterior Shading .-. 06d Window 20d Wall (Right-20) - - -- 1 165.9 • 0.51 0'.22 Insect Scre'en,(d•efault) . 04d Window 200d Wall'(Left-200) -- -- 1 91.0 `' 0:35 0.23 Insect Screeri•(default) - 05d Window 200d Wall (Left-200) -- -- 1 30.0. . 0.35..: 0.23 Insect Screen (default) 02 Window 200d Wall (Left-200) -= -- 11 40.0 0.35 0.23 Insect Screen (default) - 04 Window 200d Wall (Left-200) -- -- 1 30.0 0.49 0.19 Insect Screen (default) 39 Window 200d Wall (Left-200) -- -- 1 19.8 0.49 0.27 Insect Screen (default) 022 Window 290d Wall. (Back-290) -- -- 1 40.0 0.49 0.19 Insect Screen (default) 06d 2 Window 290d Wall (Beck-290) -- -- 1 165.9 0.51 0.22 Insect Screen•(default) 05 _ Window. , 296d Wall (Back-290) -- -- 1 70.0' 0.46 0.17 Insect Screen (default) . 36 Window 20d-Wall 2 (Right-20) -- -- 1 98.1 0.35 0.23 Insect Screen (default) 01d Window ,:1'10d Wall,2.(Eront=1,10) • �_ 19.7 11.8 1 232.5 0.51" 0.22 Insect Screen (default) 00' ' Window`''? ' >, 200d WWalh2 (Left-200)_,,0p ) ► A V* 10.0 'A 1 80.0 0.35 0.23 Insect Screen (default) ' 38 Window � 200dlWall 2 (Left 200) A i . - it 4•i 0 '� y - YA 11 ; P • fY 23.1 0.35 0.23 Insect Screen (default) 37 Window 200d,W,allY2 tl(Left 200 ' -W =I J 11N 23-1 0:35 A.23 Inn sect Screedfa eult 07d Window r 290d WaYll;2 (Bay -2901) < It> 0 191N .1,, 11;.8 r i-1.917 z236.4 0.51 0.22 Insect Screen (default) 06 Window '20d Wall 3 (Right 20)- - 8.0 7.0 '0.668 ', 37.4 0.35 0.23 Insect Screen'i (default) 07 Window 208 Wall .3 (Right-20) 8.0 7.0 1 '56.0 0.35 0.23 Insect Screen (default) . 08d Window,- 200d Wall 3•(Left-200) 14.5 11,0 1 159.5 0.51, 6.22 Insect Screen (default)- 09d Window 200d Wall 3 (Left-200) 16.5 10.0 0.982 . 162.0 0.47 0.17 Insect Screen (default) , 08d 2 Window 290d Wall 3 (Back-290) • 11.5 10.0 1 115.0 0.51 0.22 Insect Screen (default) 09d 2 Window 290d Wall 3 (Back-290)" - 11.0 10.0 0.909 100.0 0.51 0.22 Insect Screen (default) , 08 Window 20d Wall 4 (Right-20) 8.6 10.0 1. .: 80.0 0.35 0.23 Insect Screen (default) 11d Window 20d Wall 4 (Right-20) 1&0 10.0 1 160.0 0.46 0.17 Insect Screen (default) 23 Window 200d Wall 4 (Left-200) 9.5 - 10.0 1 95.0 - 0.35 0.23 Insect Screen (default) 22d Window 200d Wall 4 (Left-200) 16.0 10.0 1 160.0 , 0.49 0.19 Insect Screen (default) 24 Window 200d Wall 4 (Left-200) -- -- 1 78.0 6.35 0.23 Insect Screen (default) 26 Window 200d Wall 4. (Left-200) - 1 78.0 0.35 0.23 Insect Screen (default) 27 Window 200d Wall 4 (Left-200) -- -- 1 78.0 0.35 0.23 Insect Screen (default) 082 Window 20d Wall 5 (Right-20) 8.0 10.0 1 80.0 0.49 0.19 'Insect Screen (default) Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03.01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-01212016-433 Report Generated at:.2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence - Calculation Date/Time: 10:43, Thu, Mar 01,'2018 Calculation Description: Title 24 Analysis Input File,Name:.Madison Lot 1913=Hayer-..16.ribdx CF.1 R,PRF-01 Page Tof 16 11 Window°' 20d'Wall 5 (Right-20) 8.0 6.0 1 48.0 0.49, =0.19 Insect Screen (default) 09. Window .20d Wall 5 (Right-20) -- -- 1 13.5 0.49 0.19. Insect Screen.(default) 12 Window ;- 20d.Wall 6 (Right-20) -- -- 1 36.0 0.49 0.19 Insect'Sdeen.(default). 13 Window 50d Wall (- specify -50) -- -- 1 15.01 0.49 • 0.19 Insect Screen (default) 14 Window.. 50d Wall (- specify -50) -- -- 1 21.0 0.49 -` .0.19 Insect'Screen (default) .12d Window 50d Wall (- specify -50) - -- 1 c x 30.0 A.32 0.25 Insect Screen (defauJf) 16- Window 50d Wall (- specify -50) -- -- 1 21.0 0.49 0.19 Insect. Screen .(default) , 21 Window 230d Wall (= specify -230) -- -- 1 48.0 0.46 0.17 Insect Screen (default) 22 Window 230d Wall (- specify -230) -- -- 1 15.0 , . 0.49 0.19.- Insect Screen (default) 17 Window 140d Wall`2 (- specify -140) -- -- 1 86.0­ 0:49 0.19 Insect Screen (default) 18 Window 140d Wall 2 (- specify -140) -- -- 1 15.0 0.49 0.19 Insect Screen (default) 19 Window A 230d Wall 2 (- specify -230) -- -- 1 '80.0 _ 0.49 0.19 Insect Screen (default) 21 2 Window ! i1�4 230d Wall 7(- specify -230) -- -- 1 80.0 0.49 0.19 Insect -Screen (default) , 222 Window 230d Wall'2 (- specify -230) -- -- 1 13.5 0.49 0.19 Insect Screen (default) 21d Windows �"" id! Wall.(-;specify� 20) �, -- -- 1 30.0 0.49 ' 0.19 Insect Screen (default) 26d° Window "` 20d Walla7a(Right-20) 1%�WWU 0 wo - - 1 `128.0 0.51 , 0.22 Insect Screen (default) 30 Window �„ � 20d Wa11 7 (Right-20) >! -- -- D; `1 i "'30.0 0.49 . 0.19 Insect Screen (default) 232 Window r 20d Wall47 (Right-20): S . -�- '- 1 95 ,0 0.49 0.17 Insect Screen (default) 28 Window 200d WaIIJ5 (Lµ ft-200,)f C,� 1a 1 �`T 1: �48.0 0.35 0.23 Insect Screen (default)' 29 Window 200d Wall 5 (Left-200) -- -- 1 15.0 -0.49 0.19 Insect Screen (default) 31 Window 200d Wall 5 (Left=200) - -- 1 15.6 0.49 0.19 Insect Screen (default) 26d 2 Window 290d Wall 6 (Back-290) -- - 1 60.0 0.49 0.19 Insect Screen (default). 27d Window 290d Wall 6 (Ba6k-290) -- - 1 135.0 0.51.11 0.22 Insect Screen (default) 32 Window 290d Wall 6 (Back-290) . -- -- 1 78:0 0:35 0.23 1 Insect Screen (default) DOORS 01 02 03 • . 04 Name Side of Building Area (ft) U-factor Door 140d Wall 24.0 0.50 Door 2 50d Wall 4 72.0 0.08 Door 3 50d Wall 4 72.0 0.08 Door 4 50d Wall4 72.0 0.08 Door 5 50d Wall 4 72.0 0.08 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF. COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:.Madisori Custom Residence Calculation Date/Time: 10:43; Thu, Mar 01, 2018 Page 8 of 16 Calculation Description: -Title 24 Analysis Input File Name:. Madison Lot 196-Hayer-16.ribdx OVERHANGS AND FINS x. 01 02 03 04 05 O6 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up. - DistL Bot Up, Depth Top Up Dist R Bot Up 01d 14 0.1 14 14 0 0' 0 0 0 0 0 0 0 00 14 0.1 14 14 6 0 0 0 0 0 0 ' '0 0 07d 14 0.1 14 14 0 0 0 0 0 0 0 0 0 06 12 0.1 12 12 01 0 0 0 0 0 0 0 0 07 12 0.1, 12 12 0 0 '0. 0 0 0 0 0 0• 08d - 14 6.1 14 '14 0 0 0 0 0 0 0 6 0 09d 14AI 0." 14 14 .. 0 0 _,. 0 0 0 0 0 0 0 08d 2 1# 0.1 14 14 0 0 0 0 0 0 0 0 0 09d 2 14 0.1 14 14 0 0 0 ,: 0 0 0 0 0 0 08 10 00 10' 0"''�- 0 0 0 0 10 0 0 0 11d12 i 0:1 ..12+�raaa 3 "` 6:2 0 ,fir- w 0 sa ale. O,1Mie 0 0 :, 0 0 ' : Ox. 23 12 0.1 I. n V1 g� !r 0 �#�ef�aw� W 0.. 1 ._ 0: a V O 0 0 01 0 0 22d 12 40.1 12QP" _ _ 12 _ A w _0 0. 400 W._ 0-QW_ ow Q. '0 0 0 0 082 12 70 Q r-T12 Cl K12-'.P hY ' %_6 V ! 6..;l r_ OM' 0 0 0 0 0 11 12 0.1 ' 12 12 0 0 0 0 0 0 0 0.- 0 Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018.03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD , CF1R-PRF-01- Project Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar.01, 201.8'Page 9 of 16 Calculation, Descrioti,on:_.Title 24 Analysis Input,Fil6 Name: Madison Lot 1.96=Hayer-16:nbdx .Y _ OPAQUE Sl1RFACE CONSTRUCTIONS, 01 . , 02 03 .64 06 06' 6T, Total Cavity Winter Design ? Construction Name Surface.Type . Construction Type Framing R=value U-value Assembly Layers • Cavity % Frame: no insul. / 2x4 Top Chrd .. 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood'Siding/sheathing/decking Attic-Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Ceilings (below _ Cavity/Frame:.R-9.1 /2x4 R-36 Roof Flat attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9`insul. • Inside Finish: Gypsum Board • Cavity/'Frame: R-21 /-2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking i Cavity/Frame: no insul. /2x4 Top Chrd- 2x4 Top Chord of Roof Truss @ 24 Roof Deck Wood Siding/sheathing/decking Attic Roofgreat Attic Roofstj � Wood Framed Ceiling in. O.C. none 0.644 • •Roohn-g: Li'ght.R,00f (Asphalt.Shing/e)., Cavity/ Frame: no msul. / 2x4 Top Chrd =�� 2x4 Top Chord of Roof Truss @ 24` Roof Deck Woo`d'Siding/sheathing/decking Attic Roofliv kit Att -Abofs Wood.Framed Ceiling _. ,. AIR- ate ., none 0.644 • ; Roofing: Light Roof (Asphalt Shingle) •Cavity/.Frame: r 2x4 To Chord of Roof Truss 24 no insui. %2x4 ��Top Chid% - • 'Roof Deck Wood Sidin /sheathin /deckin the Roofinedib • At Roofs Wood Framed Ceiling in. O.C. in 0.644 Roofing: Light Roof (Asphalt Shingle) . ,. `14k H K V K U V I U ( w K . Cavity/Frame: no'insuLJ 2x4 Top, Chrd:;, 2x4 Top Chord of Roof,Truss @ 24 Roof Deck: Wood Siding/sheathing/decking AtticRoofbed3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 •Roofing` Light Roof (Asphalt Shingle) i Cavity'% Frame: no insul. / 2x4 Top Chrd - 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofbed'l 2 - Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 . Roofing, Light Roof (Asphalt Shingle) ' - Cavity l Frame,.no insuL /2x4:,Top•Chrd 2x4 Top Chord of Roof Truss :@ 24 Roof Deck. Wood Siding%sheathing/decking Attic Roofguest Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (A'sphalt:Shingle) • Cavity / Frame: ;no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofguest main Attic Roofs Wood Framed Ceiling. in. O.C. none, 0.644 Roofing. Light Roof (Asphalt.Shingle). • Cavity/Frame: no insul.. / 2x4 Top Chrd a` 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgarage Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence . Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 19B-Heyer-16:ribdx CF1 R-PRF-01 Page 10 of 16 SLAB FLOORS - 61 02 03 04 05 .06 67' Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab; master. 1713 172 None ' 0.8 No Slab 2 great 1586 91 None 0.8 . No Slab 3 liv kit• 1660 151 None 08. " No Slab 4 - media 1355 196 None 0.8 No = Slab 5 bed3 388 28`- None 0.8.,, No Slab 6 bed 1 2 1580 162 None `018• No Slab 7 guest 661 115 None 0.8 No Slab 8 guest main 2373 ' 240 None 0.8 No Slab 9 garage 1281 168 None 0.8 No- WGIM BUILDING ENVELOPE -PIERS VERIFICATIONt . 01,..d 02 03 04 ; Quality Insulation Installation (dill) ' r �Q6 I tyrinstallationCf Spray Foamansulatt'ion 20A0=Building'Envelope.Air Leakage CFM50 Required K *Noi Re uirgd `. Notl-Fte aired' -- WATER HEATING SYSTEMS L.J a C> . C . ICJ I0 1 % / .11 r_N � 0 01 02 a `� 03 r 04 '05 06 Name System Type Distribution Type Water.Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/2 DHW -Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small'Storage 50 0.66 40000-Btu/hr 6 0 Registration Number: 216-NO215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project,Name: Madison Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018, Page 11 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot-19B-Hayer-16.ribdz WATER HEATING -HERS VERIFICATION 01 02 03 04 05 06s 07 - Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 1/2 -- -- - -- — -- — SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC mstrl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC great2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 'HVAC Fan 2 Air Distribution System 2 HVAC liv3 tirOther Heating and Cooling Heating Component 3 Cooling Component 3 HVAC'Fan 3 Air Distribution System 3 System Other Heating and_Cooling HVAC media4- = . . System Heating Component 4 Cooling Component HVAC Fan 4 Air Distribution System 4 HVAC bed5 ,oeOtti * Heating and Cool ni g,i ,a- :A .� Heating Component 5 ' Cooling Component 5; HVAC Fan 5 Air Distribution System 5 v .System' AN A_ ' - x &li . HVAC gst6 aY';• • "'andv ' 'oli"Q . O{he�rHeating and.Cooling c System-4 '.• + va w- .as Heating Component 6 w4:+y lw ,!N!" v'. wyev Cooling Component 6 9e/ HVAC Fan.6 - Air Distribution System.6 E °� J t" R .CE. V# 9LJ° E R HVAC gstmn7 Other'Heating and Cooling System Heating Component 7 Cooling Component 7 HVAC Fa1. n 7 Air Distribution System 7 SPACE CONDITIONING SYSTEMS 01 02 63 04 05 .06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name_, :Heat Pump System 8:.:2:3 Heat Pump,Heating and Cooling System Heat Pump System 8 Heat Pump System 8 None None Registration Number: 216-No215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: M adisor' Custom Residence Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Calculation Description: Title 24 Analysis In putFile Name: Madison Lot 1'9B-Hayer-16.ribdx . .CFI R-PRF-01 Page 12 of 16 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace = Fuel -fired central furnace 80 AFUE . Heating Component 3 CntrlFurnace -Fuel-fired central furnace 80 AFUE - Heating Component 4 CntrlFurriace'-:Fuel-fired central furnace 80 AFUE Heating Component 5 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heati,ng.Component. 6 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 7 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - HEAT PUMPS 01 ;y02 03 04 05 '06 07 08 09 10 - f Heating Cooling Zonally; Multispeed. HERS Name T pe­ HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pum System 8 p y = Ductle�P p ., 8 3 ;. 32000 t1'9t, X%13.1 • i11 No No - Heat Pump S stem P , y 8-hers-cool _ - — *O:. .4NRr . ,► C1 1. Nows La 1 -1 j I I Ike. HERS PROVIDER Registration Number: 216-No215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 L CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD -CF1R-PRF-01,- Project' Name: Madison Custom Residence Calculation Date/Time: 10:43 Thu, Mar 01, 2018 ` Page 13 of 16.. Calculation Description: Title 24 Analysis Input File Name:*Madison L6t'196=Hayer-16.ribdx G :yaw. HVAC -COOLING UNIT TYPES .. .. 01 02> 03 '04 05 O6- 07 Efficiency . Multi'speed i Name System Type- EER SEER Zonally Controlled Compressor HERS Verification Cooling Component-1 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool .Cooling Component 2 SplitAirCond 13 -16 Not Zonal Single Speed Cooling Component 1-hers-coo'I Cooling Component 3 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 4 SplitAirCond 13 16 Zonally Controlled '' Single Speed Cooling Component 1-hers-cool, Cooling Component 5 SplitAir.Cond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 6 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component,? SplitAirCond �..�p may -13 16 Not Zonal Single Speed Cooling Component 1-hers cool ,, Pu ' DuctlessHeatPum 11_. 13.1 �+°. 614 Not Zonal b Sin le S eed Cooling Component 1-hers-cool IGJ, `VTR INWW IRMPM a MR111111, " In a qRw if :. 0 a Af -MP w . HVAC COOLING -HERS VERIFICATION ` H F R c P RQVI OF R 01 02- 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 . Required" Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Cooling ;Component 5-hers-cool Required 350 Required Required Required . Cooling Component6-hers-cool Required 350 Required Required' Required Cooling Component 7-hers-cool 'Required 350 Required Required Requited Heat Pump System. 8-hers-cool Not Required Not Required Not Required Required Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE RESIDENTIAL.PERFORMANCE COMPLIANCE METHOD Project Name: Madison Custom Residence. Calculation Date/Time: 10:43, Thu, Mar 01, 2018 f Calculation Description: -Title 24 Analysis Input File Name: Madisori Lot 19B-Hayer-16.ribdx CF1 R-PRF-01 Page 14 of 16 HVAC - DISTRIBUTION SYSTEMS " 01 02 03 04 05- 06 '. 07- Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 _ LowLICod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 1-hers=list Air Distribution'System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2-hers-dirt Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3-hers-dirt Air Distribution.System 4 . LowLICod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 4-hers-dist Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5-hers-list' Air Distribution System 6 1 DuctsAttic rrl. Sealed and tested 8 Attic None Air Distribution System 6-hers-list ;. Air Distribution System 7 #r� DuctsAttic Sealed and tested 8 Attic V None Air Distribution System 7 hers4st no*cts ,` ,. None HVAC-DISTRIBUTION - HERS VERIFICATION 'Aft, '' - �• 01 . 112 - • - '­­OS',a,, '�. 04 �05 `.' OC 07 68 Name Duct Leakages Verification �D uIcT. Leak gem Target (%) VerifiedDuctk Location I Verified Duct% Design Muried Ducts Deeply Buried Ducts - Low -leakage Air Handler Air bistritiution System 1-hers list Required 6.0 Required Not Required Not Required Not Required -- Air Distribution System 2-hers-dist Required 6.0 Not Required Not Required Not Required Not Required -- Air Distribution System 3=hers-list Required. 6`.0 Not Required Not Required Not.Required Not Required -- Air Distribution System 4-hers-dist Required 6.0 Required Not Required. Nof.Required Not Required -- Air Distribution System 5=hers-list - Required 6.6 Not Required Not Required Not Required - Not Required -- Air Distribution System 6-hers-dist Required 6.0 Not`Required . Not Required Not Required. Not Required -- Air Distribution System .7-hers-list. Required -6.0 Not Required Not Required Not Required Not Required -- , Registration Number: 216-N0215783G-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2018-03-01 10:56:17 Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE;COMPLIANCE METHOD CF1R-PRF-01 Ptoject Name: Madison Custom Residence r Calculation Date/Time: 10:43, Thu, Mar 01, 2018 Page 15 of 16 Calculation Description: Title 24 Analysis Y _ Input File Name: Madison Lot;1913-1-layer-16.ribdx HVAC - FAN SYSTEMS 01 02 03 04 Name 'Type Fan Power.(Watts/CFM) HERS Ve7rificatiom. HVAC Fan-1. Single Speed PSC Furnace Fan . 0.68 . HVAC Fan i-hers-fan HVAC Fan 2 Single•Speed PSC Furnace Fan 0.58 HVAC Fan ,2-hers-fan ` HVAC Fan 3 - Single Speed PSC Furnace Fan 0.58 '"HVAC Fan'37hers:fan HVAC Fan 4c^ Single Speed PSC Furnace Fan 0.5.8 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furiace Fan 0.58 HVAC Fan 5-hers-fan- HVAC Fan 6 Single,Speed PSC Furnace Fan 0.58 HVAC Fan 6-hers-fan HVAC Fan 7 Single Speed PSC Furnace Fan 0.58 .HVAC Fan 7-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 - 02 03 Name'""= .. Verified `FartWatt Draw + Required Fan Efficiency (WattsICFM) HVAC Fan 1-hers! n; ,- N :.:.: '"r" �"'`�.�h Re-quired APM X*Ag-.ogteq..� Ate► �1 0`58 ;. HVAC Fan2-hers fan s ��a� ff ..:,.; I It, , ' 0.58 HVAC Fan'3-hers fan 3!. F rReg6ired Y `RNIP Lend HVAC Fan 4-hers-fan'r - ®. R uiied"� ` . 0.58 HVAC Fan 5-hers-fan - Required ' _ - 0.58 . HVAC Fan 6-hers-fan Required 0.58 HVAC Fan 7-hers-fan Required 0'.58 ., IAQ (Indoor Air Quality) FANS 01" 02 '03 04 05,, ,. 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ:Recovery EffecitiveneSs(%)L HERS Verification SFam IAQVentRpt ., 208.47 ' 0.25 Default "0 e r Requireds. Registration Number: 216-N0215783G-000000000-0000 Registration Date/Time: 2018-03-01 10:56:17 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2018-03-01 10:45:27 r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE -COMPLIANCE METHOD Project Name: Madison Custom Residence Calculation Date/Time: 10;43,;Thu, Mar 01, -2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 19B-Hayer-16.ribdx CFI R-PRF-01 Page 16'of 16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that'this Certificate of Compliance documentation is accurate and complete. s Documentation Aui or' Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-03-01 10:56:17 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive . City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780' RESPONSIBLE PERSON'S DECLARATION STATEMENT 'following I certify the under penalty of perjury, under the.laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. �� vim.. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to'the requirements of -Title 24, Part 1 and Part 6 of the California Code of Regulations. ' 3. The building design features or; design features identified;on=this•Certificate Compliance the information documents, system of are consistent with provided onbther applicable compliance Worksheets, calculations, plans ndapecifications submitted'^to the enforceme_ _gency fo�r:approval w hi ilding.permit application. y Responsible.DesignerName:1! �R1 Signature°.. . Tim Scott 1esponsitile'5esigner T 1 Company: HER5 Date Signed: UCYVIDER Scott Design. and Title 24, Inc. 20 8 03-01 10:56:177 N , Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number:' 216-N0215783G-000000000-0000 Registration Date/Time: 2018.03-01 10:56:17 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: CaICERTS inc. Report Generated at: 2018-03-01 10:45:27