Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
07-0490 (AR) Title 24 Revision 1
. - TITLE 24 REPORT . Title 24 Repofor: OAKES'S ESIDENCE LA QUINTA, CA Project Designer: OAKE'S RESIDENCE LA QUINTA CA I ®F LA ()UINTA Report Prepared By: FDA pE�'T. BUILDING &SAF �® ADAdriana G I L P p RCS!/ CONSTRUCTIO Palm Desert, 4 854 iA 92260ie Way Ste. $ -12-o7— sY (760) 404-7917 A Job Number: ADY175-0305 Date: 4/12/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number. ADY175-0305 User Number. 5553 5 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 EnergyPro 4.3 by EnergySoft Job Number. ADY175-0305 User Number: 5553 . Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R ._OAKE.S_S_BE.S1DEN-CF [X -J Single Family ❑ Addition Total Conditioned Floor Area: 41_12/200.7 Project Title -LAO.UINTA N.ew ❑ Multi Family ❑ Existing + Add/Alt Date Project Address ft2 Building Front Orientation: (W) 270 deg Building Permit # Adr_iana-GH ft2 Fuel Type: (760) 404-7917 Natural Gas Documentation Author 160 ft2 Telephone Plan Check/Date _Ener_��yero Average Ceiling Height: 8.0 CA_Cl.imatsZone_1.5 Area: Field Check/Date Compli ce Method Number of Dwelling Units: 1.00 Climate Zone Ratio: TDV Standard Proposed Compliance kBtu/sf-yJ Design Design Margin Vent Space Heating 0.51 0.66 -0.15 Hgt. Space Cooling 114.50 109.57 4.93 Fans 16.79 15.96 0.83 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00_ Totals 131.79 126.19 5.60 Percent better than Standard: 4.3% Building Type: [X -J Single Family ❑ Addition Total Conditioned Floor Area: 160 ft2 N.ew ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (W) 270 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 160 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 25 ft2 Avg. U: 0.65 Number of Dwelling Units: 1.00 Ratio: 15.6% Avg. SHGC: 0.40 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt _Roof__ Wood- x.6.0_ -0-026_ -R=38_ _R-_0_0_ _0_x.8 _1N.alL_ Wood_ 42 _0102 _R-9.3_ __R_-0_0 -- 2Z0_ 90 _Wall_ Wood_ 1.61 -0-1-02- _R-1.3_ X0_0 0 90 Wall_ Wood- _161-0102 -R-1.3_ X0_0_ X8.0__9.0 Gains Condition Y / N Status JA IV Reference Location / Comments New D1 --A8 WHOLE New 09-43 WHOLE N.ew 09=A3 WHOLE New .0.9=A3 WHOLE I EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY175-0305 Paae:3 of 8 1 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R OAKES'S RESIDENCE 4/12/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments _L - ind.ow—Er_ont_pN)- —25_0 _0_6.50_NERC _0 40 -NERC _27.0_ _9.0 New—DEEAULT-DB.LP-9NE 1 EME 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments EnergyPro 4.3 by EnergySoft User Number. 5553 Job Number: ADY175-0305 Paae:4 of 8 1 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R OAKES'S RESIDENCE 4/12/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. _ Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name Title/Firm: OAKE'S RESIDENCE Address: LA QUINTA, CA Telephone: Lie. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Name: ADRIANA GIL Title/Firm: Adriana Gil Address: 74-854 Velie Wav Ste. #8 1 EnergyPro 4.3 by EnergySoft User Number: 5553 Jib Number: ADY175-0305 Paae: 5 of 8 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum compcnent performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ e§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ 0 ❑ e§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. b. outside air intake with damper and control, flue damper and control ❑ N 112. ❑ No continuous burning gas pilot lights allowed. E]i U ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ IR ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ ' permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ ❑ .CF -6R Form: EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY175-0305 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfikration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ 0 ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ ❑X ❑ § 150(1): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ 0 ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ' ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ' ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY175-0305 Page:6 of 8 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not applicable. ENFORCE - NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ © ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating❑ Q El dampers. S. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑x ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑X ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ X❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ X❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ n ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ a ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are❑. X❑ ❑ controlled by an occupant sensor that complies with Section 1' 9(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ X❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by Energysoft User Number: 5553 Job Number. ADY175-0305 Page:7 of 8 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE OAKES'S RESIDENCE 4/12/2007 (SYSTEM NAME FLOOR AREA Existing HVAC System 160 26.0 of 70.0 of Outside Air 0 Cfm 70.0 of :OGLING SYSTEM 11.0 / 77.6 of Outside Air 0 Cfm 76.0/61.7 of EnerovPro 4.3 by Er Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating Coil COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 271 6,062 964 71 3,014 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6,0621 964 3 014 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1% Return Air Ducts `S 76.0 / 61.7 of® 55.0 / 53.8 of User Number: 5553 Cooling Coil h Return Air Ducts '� Job Number: ADY175-0305 Supply Air Ducts 110.0 of ROOMS 70.0 of Supply Air Ducts 55.0 / 53.8 of 44.4% R.H. ROOMS 76.0 / 61.7 of of 8