Loading...
0102-140 (TT) Title 24I4 k; TITLE 24 REPORT I Title 24 Report for: THE YOUNG RESIDENCE La Quinta„ Ca. 92253 '-7 F) - 2.80 $►cgpA�E Covtr Project Designer: KRISTI W. HANSON., ARCHITECT 44-850 Las Palmas, Suite A, Palm Desert, Ca. 92260 (760) 776-4068 �- Report Prepared By: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED R Krown CEA 98-93-204 FOR CONSTRUCTION KROWN MECHANICAL DESIG P.O. BOX 621 DATE Io Bo BY RANCHO MIRAGE, CA 92270-0621 Ttcz 5Zf k 60) 770-004" Job Numbe Date: 8/5/00 T C*rtiti*d RG*rpy Asely s Allard F. Komn NR 0040 -Wo �� r,2- 9643204 CA8EC CoMailr�io /l�odcaeto�n d Ov�id6ng Enrgy Ganu�riY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoff Job Number: 00048 User Number: 2366 I < TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance...:_::.; 3 Form MF -1 R Mandatory Measures Checklist 8 Form C -2R Computer Method Summary 9 Form ENV -3 Proposed Construction Assembly 16 Form CF -6R Installation Certificate 20 HVAC System Heating and Cooling Loads Summary 27 EnergyPro 2.1 By EnergySoft Job Number: 00048 User Number: 2366 Certificate of Compliance: Residential (Part1 of 2) -CF-1R THE YOUNG RESIDENCE 8/5/00 Project Title Date 76-280 Birkdale Court, La Quinta, Project Address Building Permit # KROWN MECHANICAL DESIGN (760) 770-0044 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check ( Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,788 if Total Conditioned Slab Area: 6,788 fl? Building Type: (check one or more) X❑ Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 195 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Solid Wood Door Wood FENESTRATION 0.387 Exterior Door Shading Devices Type Orientation Area Const. Interior Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Built-up/Air/R-38/Gyp (Truss) Wood 0.026 Exterior Roof Tile/Attic/R-38/Gyp Wood 0.029 Exterior Roof Tile/R-38/Gyp (2X12) Wood 0.030 Exterior Roof R-21 Wall (W.21.2(6.16) Wood 0.056 Exterior Wall R-21 Partition Wood 0.057 Exterior Wall Solid Wood Door Wood FENESTRATION 0.387 Exterior Door Shading Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc. shadescreen etc. Yes / No Yes / No Skylight 78.3 0.80 0.57 None None ❑ X❑ ❑ X❑ Front (South) 70.0 0.55 0.53 Drapery Bug Screen X❑ ❑ ❑ X❑ Front (South) 1.8 0.46 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Front (Southwest) 17.0 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Front (Southwest) 17.0 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (West) 17.0 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (West) 1.8 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (West) 17.0 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (West) 10.0 0.70 0.46 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (West) 16.0 1.40 0.60 Drapery Bug Screen ❑ X❑ ❑X❑ Left (Northwest) 17.0 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (Northwest) 1.8 0.49 0.52 Drapery Bug Screen ❑ ❑ X❑ Run Initiation Time: 08/05/00 13:03:21 Run Code: 965480601 EnergyPro 2.1 By Ener oft User Number: 2366 Job Number: 00048 Pa e:3 of 30 Certificate of Compliance: Residential (Part 1 of 2) CF -'FR THE YOUNG RESIDENCE 8/5100 - Project Title Date 76-280 Birkdale Court, La Quinta, Project Address Building Permit # KROWN MECHANICAL DESIGN (760) 770-0044 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,788 fit Total Conditioned Slab Area: 6-788f? Building Type: (check one or more) © Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 195 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc. shadescreen, etc. Yes / No Yes / No Left (Northwest) 17.0 0.49 0.52 Drapery Bug Screen El FX1 El Rear (North) 17.0 0.49 0.52 Drapery Bug Screen ❑ 0 ❑ X❑ Rear (North) 17.0 0.49 0.52 Drapery Bug Screen ❑ E ❑ a Rear (North) 570.0 0.65 0.52 Drapery Bug Screen 0 ❑ ❑ Y Rear (North) 66.0 0.49 0.52 Drapery Bug Screen 0 ❑ ❑ X❑ Rear (North) 1.8 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Right (East) 1.8 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑X❑ Right (Southeast) 1.8 0.49 0.52 Drapery Bug Screen ❑ a ❑ o Left (West) 72.0 0.49 0.52 Drapery Bug Screen X❑ ❑ ❑ 0 Left (West) 90.0 0.65 0.52 Drapery Bug Screen Q ❑ ❑ 0 Rear (North) 16.5 0.70 0.48 Drapery Bug Screen X❑ ❑ ❑ X❑ Right (East) 8.0 0.70 0.48 Drapery Bug Screen 0 ❑ ❑ E Run Initiation Time: 08/05100 13:03:21 Run Code: 965480601 EnerrElBy Ener oft User Number: 2366 Job Number: 00048 Pa e:4 of 30 Certificate of Comaliance: Residential (Part 1 of 2) CF -1-R THE YOUNG RESIDENCE 8/5/00 Project Title Date 76-280 Birkdale Court, La Quinta, Overhang Side Fins Project Address SF Building Permit # SHGC KROWN MECHANICAL DESIGN (760) 770-0044 shadescreen, etc. Yes / No Plan Check IDate Documentation Author Telephone (East) 45.0 0.65 Computer Performance 15 Drapery Field Check I Date Screen Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only 0 GENERAL INFORMATION Right Total Conditioned Floor Area: 6,788 If 8.0 Total Conditioned Slab Area: 6,788 ft2 0.48 Building Type: Bug (check one or more) ❑ X❑ Single Family Detached (SFD) ❑ Addition Alone ❑ X❑ ❑ Single Family Attached (SFA) ❑ Existing Building (South) ❑ Multi -Family ❑ Existing Plus Addition 0.48 Front Orientation: (South) 195 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Screen Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc. shadescreen, etc. Yes / No Yes / No Right (East) 45.0 0.65 0.52 Drapery Bug Screen ❑ 0 ❑ X❑ Right (East) 8.0 0.70 0.48 Drapery Bug Screen ❑ 0 ❑ X❑ Front (South) 6.0 0.48 0.52 Drapery Bug Screen X❑ ❑ ❑ X❑ Front _(South) 15.0 0.70 0.48 Drapery Bug Screen X❑ ❑ ❑ X❑ Front _(South) 84.0 0.70 0.48 Drapery Bug Screen ❑ X❑ ❑ X❑ Right (East) 6.3 0.49 0.52 Drapery Bug Screen ❑ X❑ ❑ X❑ Right _(East) 90.7 0.55 0.53 Drapery Bug Screen X❑ ❑ ❑ X❑ Right (East) 48.0 0.65 0.52 Drapery Bug Screen X❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 08106/00 13:03:21 Run Code: 965480601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Pa e:5 of 30 Certificate of Compliance: Residential (Part 2 of 2) CF -111 THE YOUNG RESIDENCE 8/5/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Equipment Minimum Distribution HeatingType and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central_Furnace 80% AFUE nuns in Attic 4.2 Setback LIVING ZONE Central Fumace 80% AFUE Ducts in Attic 4.2 Setback GUEST BEDROOMS 1 & 2 Central Fumare 80% AFUE Ducts in Attic 4.2 Setback GUEST 3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 49 Sethack I IVING 7QNF Split Air Conditioner 19 O SEER n u .tc in Attic 49 Setback MASTFR SI IITF aft Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback GUEST BEDROOMS 1 & 2 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback GUEST 3 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank InsuL System Name Type Type Syst. Btu/hr (gal) Efficiency toss (%) R -Value A_O SMITH FGR -100-230 Small Gas Recircrrime+Temp Z _ 75000 im 0.43 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: R Krown CEA 98-93204 Title/Firm: KRISTI W. HANSON, ARCHITECT Title/Firm: KROWN MECHANICAL DESIGN Address: 44850 Las Palmas, Suite A. Address: P.O. BOX 621 Palm Desert., Ca. 92260 RANCHO MIRAGE, CA 92270-0621 Telephone: 76o 77 U . #: AN A4 13 (snature) ate) En ' rceme t Agen Name: Title/Firm: _ Address: Telephone_ Teleph ne: (76o) 770-0044 � Corr ( nature) (date) (signature/stamp) (date Run Initiation Time: 08105/00 13:03:21 Run Code: 96 0601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 0000 Page:6 of 30 Certificate of Compliance: Residential (Addendum) CF -1 R THE YOUNG RESIDENCE 8/5/00 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "A O SMITH FGR -100-230" Energy Factor = 0.430. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "LIVING ZONE" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 728 sqft Covered Slab Floor, 3.50" thick at Living/Kit/Dine. Etc. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2911 sqft Exposed Slab Floor, 3.50" thick at Living/Kit/Dine. Etc. The HVAC System "MASTER SUITE" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R - Verify Thermal Mass: 1059 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R - Verify Thermal Mass: 575 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "GUEST BEDROOMS 1 & 7must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping RMASS Design(see C -2R) - Verify Thermal Mass: 683 sqft Covered Slab Floor, 3.50" thick at Bedrooms 2 & 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 375 sqft Exposed Slab Floor, 3.50" thick at Bedrooms 2 & 3 The HVAC System "GUEST X must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 373 sqft Covered Slab Floor, 3.50" thick at Bed/Bath 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Exposed Slab Floor, 3.50" thick at Bed/Bath 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field I Run Initiation Time: 08/05/00 3.0 Run Code: 965480601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:7 of 30 Mandatory Measures Checklist: Residential MF -IR . NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shatt.be consideredby-aU-parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures X 1150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. 150(b): Loose fill insulation manufacturers labeled R -value. -§150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 punch. §118: Insulation specified or installed meets quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Door, and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X §110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACOA. §150(1): Setback thermostat on all applicable heating and/or cooling systems. a§1500): pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. `§150(m): Ducts and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181S, or UL181 B and other applicable specified test for longevity given in 150(m). 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. X❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36' of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Central Furnaces, pool heaters, spa heaters or household cooling appliances have no constant pilot light. Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumen It or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 IumensMrat or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:8 of 30 Computer Method Summary (Part 1 of 3) C:2rt THE YDUNG RESIDENCE Project Title 8/5/00 Date 76-280 Rirkdala ('ourt lg Qt tints' Project Address ' Building Permit # KROWN MECHANICAL DESIGN (760) 770-0044 Documentation Author Telephone Plan CheckrDate Computer Pert rmance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.70 4.68 -0.98 Space Cooling 36.81 28.21 8.60 Domestic Hot Water 4.20 7.15 -2.95 Totals 44.70 40.04 4.67 GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 6,788 Single Fam Detached (South) 195 deg 1.00 1 BUILDING ZONE INFORMATION Zone Name I IVIN(. 7t7NF MASTER SUITE M IIFST BEDROOMS 1 8 2 GUEST 3 Floor Area Volume 3,J�9 1,F�4 1,MR 457 OPAQUE SURFACES Solar Act. Gains Type Area U -Val. AZm. Tilt Y / N Roof 950 o 096 0 0 Rnnf — 2 702 —0 024 0-0 Raaf 113 — n 0m n i5 Wali 171 0059 195 90 Wall 7 n r199206_go Wall 7 �0_(T-A X29 -qn Wall 7 n059 9SI go Wall 42 n p59 255_90 Wall 7 nM_ 274 -qn Wall— 236 —n rFP 7ffi_ go Wall 84 0 -Mg 296 90 Wall 42 0.059 315 go Wall 7 0059 31A gn Wall 7 n 059 341 _90 Wall 7 �0 rFA 4 _90 Wall 552 r) ftcp i5 r Wall 42 n0r-A 75 -qn Wall 163 n OSA 1 r's Wall 42 — 0 Mg 135 90 Wall 578 0057 —0 9Q Door 24 �Q 387 — 0 91) Rnnf 416 n rob n a Rnnf 1918 n 029 Wall 41 n(T-A 195 _go Wall 140 nrFA Wall 240 �Q 059 is 90 Wall 424 _-rFA ifls go Wall 8 �Q MSZ 0 go Roof 1 058 �0 029 0 0 Floor Construction Type: X❑ Slab Floor ❑ Raised Floor Total Conditioned Volume: 81,248 Slab Floor Area: 6,788 # of Thermostat Vent Units Zone Type Type Hgt. Area 054_ 1 iving I ivingStat —2 n/a 0 24 Sleepj;rl Slee ingS at _/a 0.16 Sleeninnaa Sle - ing,¢tat _2 n 0.07 Sleeping SleepingStat 2 n Form 3 Reference Location / Comments Computer Method Summary (Part 1 of 3) C -2R THF Y01 JNG RESIDENCE Project Title 76 Rirkdale Court La CJuinta' 8/5/00 Date -?80 Project Address ' Building Permit 9 " JSB.OWN WCHANICA DESIGN (760) 770-0044 Author Telephone Plan-Check/Date C:omnuter Performance 15 Field CheckfDate Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.70 4.68 -0.98 Space Cooling 36.81 28.21 8.60 Domestic Hot Water 4.20 7.15 -2.95 Totals 44.70 40.04 4.67 GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 6,788 Single Fam Detached (South) 195 deg 1.00 1 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt W;111 565 nose 19 —go Wall 131 n rFA 9FIS An Wall 113 nn59 is _9Q Wall 235 n.o59 1fF; 90 Wall 36 n.057 0 _90 Roof 453 n n29 n —n Wall 247 n.nsg 195 _go Wall 39 n.d59 9ffi —90 Wall 95 n OSn iff; _9d Wall 289 n n57 n _ D Floor Construction Type: N -Slab Floor Raised Floor Total Conditioned Volume: 81,248 Slab Floor Area: 6,788 # of Thermostat Vent Units Zone Type Type Hgt. Area Solar Gains Y / N Form 3 Reference Loccation4-Comments Run Initiation Time: 08/05/00 13:03:21 Run Code: 965480601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page: 10 of 30 ■ Run Initiation Time: 08/05/00 13:03:21 Run Code: 965480601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page: 10 of 30 Computer Method Summary (Part 2 of 3) C -2R THE YOUNG RESIDENCE 8/5/00 Project Title Date FENESTRATION SURFACES # Type U -Value Area SHGC Act. Azm. Glazing Type Tilt Location/ Comments Sky aght Rear (North) 743 n 8m 0.57 0 _0 Brictoy I�Slvlights Rro 7e Fum/CU-1 2 Window Front (South) 70.0 0.550 0.53 195 90 Double NonMtl Tinted Default Furn/CU-1 3 Window Front (South) 1.8/ 0.490 0.52 195 90 Fleetwood 250!3000 Lo E Brz Furn/CU-1 4 Window Front (Southwest) 17.0' 0.490 0.52 206 90 Fleetwood 25D13000 Lo E Brz Fum/CU-1 5 Window Front (Southwest) 17.0' 0.490 0.52 229 90 Fleetwood 250!3000 Lo E Brz Fum/CU-1 6 Window Left ((est) 17.0' 0.490 0.52 251 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 Z Window Left est) 1.8 � 0.490 0.52 255 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 8 Window Left (West) 17.0' 0.490 0.52 274 90 Fleetwood 250!3000 Lo E Brz Furn/CU-1 3 Window Left est) 10.0! 0-700 0.48 285 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 1Q Window Left (West) 16.0 1.400 0.60 285 _90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 11 Window Left (Northwest) 17.0 0.490 0.52 296 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 12 Window Left (Northwest) 1.8-- 0.490 0.52 315 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 13. Window Left (Northwest) 17.0^ 0.490 0.52 319 _90 Fleetwood 250/3000 Lo E Brz Furn/CU-1 14 Window Rear (North) 17.0' 0.490 0.52 341 90 Fleetwood 250;3000 Lo E Brz Fum/CU-1 15 Window Rear (North) 17.0' 0.490 0.52 4 90 Fleetwood 250/3000 Lo E Brz fum/CU-1 16 Window Rear (North) 90.0-' 0.650 0.52 15 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 17 Window Rear (North) 100.0- 0.650 0.52 15 90 Fleetwood 250/3000 Lo E Brz FUm/CU-1 18 Window Rear (North) 60.0- 0.490 0.52 15 90 Fleetwood 250/3000 Lo E Brz Fum/CU-1 12 Window Rear (North) 2000 0-650 0.52 15 90 Fleetwood 250,3000 Lo E Brz Furn/CU-1 20 Window Rear (North) 1.8' 0.490 0.52 15 90 Fleetwood 250!3000 Lo E Brz Fum/CU-1 21 Window Right (East) 1.8✓ 0.490 0.52 75 90 Fleetwood 25013000 Lo E Brz furn/CU-1 22 Window Right (Southeast) 0.490 0.52 135 90 Fleetwood 2500000 Lo E Brz Fum/CU-1 23 Window Left (West) 24.0/ 0.490 0.52 285 90 Fleetwood 25013000 Lo E Brz furn/CU-2 24 Window Left (West)_ 90.0' 0.650 0.52 285 90 Fleetwood 250/3000 Lo E Brz Fum/CU-2 25 Window Rear (North) 90.0- 0.650 0.52 15 90 Fleetwood 250/3000 Lo E Brz Furn/CU-2 26 Window Rear (North) 90.0' 0.650 0.52 15 90 Fleetwood 2501.3000 Lo E Brz Fum/CU-2 27 Window Rear (North) 16.5 0.70D 0.48 15 90 Fleetwood 250/3000 Lo E Brz FUm/C11-2 28 Window Right (East) 8.0- 0.700 0.48 105 90 Fleetwood 250/3000 Lo E Brz Furrr/C-U-2 29 Window Right (East) 45.0/ 0.650 0.52 105 - 90 Fleetwood 250/3000 Lo E Brz Furn/CU-2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. REQ. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 None 1.00 - - - 2 Drapery 0.68 Bug Screen 0.76 10.0 7.0 13.0 0.1 99.0 99.0 - 3 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - - - - - - - - - 4 Drapery 0.6B Bug Screen 0.76 - - - - - - - - - 5 Drapery 0.6B Bug Screen 0.76- 6 Dragpery 0.6B Bug Screen 0.76 - - - - - - - - - - - - 7 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - 8 Drapery 0.68 Bug Screen 0.76 9 Drapery 0.68 Bug Screen 0.76 ------------ 10 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - - - - 11 'Drapery 0.68 Bug Screen 0.76 12Dra - _ pery 0.6B Bug Screen 0.76 --------- 13 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - - - - 14 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - - - - pery 0.68 Bug Screen 0.76 - _ 16 Drapery 0.68 Bug Screen 0.76 10.0 9.0 15.0 0.1 99.0 5.0 _ 17 Drapery 0.68 Bug Screen 0.76 10.0 10.0 22.0 4.0 99.0 24.0 - - 18 Drapery 0.68 Bug Screen 0.76 3.0 20.0 34.0 0.1 99.0 99.0 - - - - 19 Drapery -2d 0.6B Bug Screen 0.76 10.0 20.0 34.0 4.0 99.0 99.0 - - - - - 20 Drapery 0.66 Bug Screen 0.76 - - - - - - - - - - - 21 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - - - - 22 Drapery 0.66 Bug Screen 0.76 _ - - - - - - - - - 23 Drapery 0.68 Bug Screen 0.76 6.0 4.0 99.0 0.1 21.0 99.0 - - - - - 24 Drapery 0.68 Bug Screen 0.76 10.0 9.0 99.0 0.1 4.0 99.0 - - - 25 Drapery 0.68 Bug Screen 0.76 10.0 9.0 28.0 0.1 99.0 99.0- 26 Drapery 0.68 Bug Screen 0.76 10.0 9.0 6.0 0.1 16.0 84.0 - - - - - 27 Drapery 0.68 Bug Screen 0.76 5.5 3.0 2.0 3.0 5.0 99.0 - - - 28 Drapery 0.68 Bug Screen 0.76 4.0 2.0 2.0 4.0 3.0 29.0 - - 29 Drapery 0.68 Bug Screen 0.76 - - - - - I EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Paw: 11 of 30 1 Computer Method Summary (Part 2 of 3) C4R THE YOUNG RESIDENCE 8/5/00 Project Title Date FENESTRATION SURFACES # Type Area U -Value SHGC Act. Glazing Type Azm. Tilt Location/ Comments M Mndow Right (Fast) R n 0.70D 0 48 in _9Q Fleetwood 250!'.3000 I o F Brz Fum/ . 1-2 31 Window Front (South) 6.0 0.490 0.52 195 90 Fleetwood 250/3000 Lo E Brz FUMCU3 32 Window Front (South) 15.0 0.700 0.48 195 90 Fleetwood 250/'3000 Lo E Brz Fum/CU3 33 Window Front (South) 42.0 0.700 0.48 195 90 Fleetwood 250/'3000 Lo E Brz Furn/CU3 34 Window Left Mest) 48.0 0.490 0.52 285 90 Fleetwood 250(3000 Lo E Brz Furn/CU-3 35 Window Rear (North) 6.0 0.490 0.52 15_ 90 Fleetwood 250/3000 Lo E Brz Fum/CU3 36 Window Right (.Fast) 63 0.490 0.52 105 90 Fleetwood 250/3000 Lo E Brz Furn/CU3 37 Window Right (East) 90.7 0.550 0.53 105 90 Double NonMtl Tinted Default Fum/CU3 -M SS'ght Rear (North) 4.0 0.800 0.57 0 0 Bristolite Skylights Bronze Fum/CU3 -M Window Front (South) 42.0 0"700 0.48 195 90 Fleetwood 250(3000 Lo E Brz Fum/CU3 90 Window Right (East) 48.0 0.650 0.52 105 90 Fleetwood 250/3000 Lo E Brz Fum/CU3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin -Right Fin # Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Fdgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt. 30 Drapery 0.68 Bug Screen 0.76 31 Drapery 0.68 Bug Screen 0.76 3.0 2.0 99.0 2.2 99.0 10.0 - - - - - 32 Drapery 0.68 Bug Screen 0.76 2.5 2.0 3.5 3.0 4.5 20.0- 33 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - 34 Drapery 0.6B Bug Screen 0.76 8 0 6 0 99 0 0.1 %0 %0 - - - - - - 36 Drapery 0.68 Bug Screen 0.76 3.0 2.0 99.0 2.2 10.0 99.0 - - - - Drapery 0.6B Bug Screen 0.76 - - - - - - - - - 37 Drapery - 0.68 Bug Screen 0.76 8.0 5.7 10.0 2.2 99.0 - - 99.0 38 None 1.00 None 1.00 - - - - - - - - - - - - - - - - - - - - - - - - 39 Drapery 0.68 Bug Screen 0.76 - - 40 Drapery 0.68 Bug Screen 0.76 - 8.0 - - 6.0 99.0 0.1 99.0 - - - - - - - 99.0 Run Initiation Time: 08/06/00 13:03:21 Run Code: 966480601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page: 12 of 30 Computer Method Summary (Part 3 of 3) C -2R THE YOUNG RESIDENCE 8/5/00 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN F2 Factor Insulation R -Val. Depth Location / Comments Area Thick. Heat Fum/CU-1 Inside Location Type (so (n.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete HeayMiaht 728 Concrete, Heavyweight 2,911 1 350 98 28 n M n/a 0_98 n/a _2 0 Fum/CU-1 /Slab on Grade Fum/CU-1 / Slab on Grade Concrete, HeamMight 1,069 3_50 98 0_98 n/a 2 Fum/CU-2 / Slab on Grade Concrete, Heavyweight 575 3.50 28 0_98 n/a 0 Fum/CU-2 / Slab on Grade Concrete HealoMmpht 683 33"50 _2$ 0_98 n/a 2 Fum/CU3 / Slab on Grade PERIMETER LOSSES Type Length F2 Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 90 0_76 00 0 Fum/CU-1 Slab Perimeter 112 076 _0_0 0 Fum/CU-1 Slab Perimeter 50 076 0.0 0 Furn/CU-2 Slab Perimeter 750_76 0.0 0 Fum/CU-2 Slab Perimeter 103 0_76 00 0 Fum/CU3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct . Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE 80%AFUE Ducts in Attic 442 Setback 4.2 Setback LIVING ZONE Central Furnace Ducts in Attic MASTER SUITE Central Furnace 80%AFUE Ducts in Attic 4.2 Setback GUEST BEDROOMS 1 & 2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback GUEST 3 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.0 SEEK Ducts in Attic 442 Setback LIVING ZONE Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback MASTER SUITE Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback GUEST BEDROOMS 1 & 2 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback GUEST 3 WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss Ext. A O SMITH FGR -100-230 Small Gas Recirc/Time+Temp 2 75,000 100 0.43 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. 1 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Paoe:13 of 30 1 Computer Method Summary Minimum (Part 3 of 3) C= 2R THE YOUNG RESIDENCE 8/5/00 Project Title and Location Duct Date THERMAL MASS FOR HIGH MASS DESIGN pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete ewomeight X76 3 98 n Q n/a a Fum/CU3 / Slab on Grade Concrete Hea4weight 373 3_50 28 098 n/a 2 Fum/CU3 / Slab on Grade Concrete, He_yMiaht 04 350 98 Q,9a n/a 0 Fum/CU3 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 26 0_76 0.0 0 Fum/CU3 Slab Perimeter 62 -Q-M QD 0 Fum/CU3 WI9_L�3b�li�ub� Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location/ pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Insul. Hydronic Piping Pipe Pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Ratedt Tank Energy Facts Tank Insul. WATER HEATING SYSTEMS Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss M Eft. For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 08/05/00 13:03:21 Run Code: 965480601 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page: 14 of 30 Computer Method Summary (Addendum) G2 -R - - THE YOUNG RESIDENCE 8/5/00 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "A 0 SMITH FGR -100-230" Energy Factor = 0.430. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "LIVING ZONE" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 728 sqft Covered Slab Floor, 3.50" thick at Living/KittDine. Etc. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2911 sqft Exposed Slab Floor, 3.50" thick at Living/KAtDine. Etc. The HVAC System "MASTER SUITE" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R - Verify Thermal Mass: 1056 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R - Verify Thermal Mass: 575 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "GUEST BEDROOMS 1 & 7' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping MEM -MASS Design(see C -2R) - Verify Thermal Mass: 683 sqft Covered Slab Floor, 3.50" thick at Bedrooms 2 & 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 375 sqft Exposed Slab Floor, 3.50" thick at Bedrooms 2 & 3 The HVAC System "GUEST X must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 373 sqft Covered Slab Floor, 3.50" thick at Bed/Bath 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Exposed Slab Floor, 3.50' thick at Bed/Bath 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HFzR5 rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field Run Initiation Time: 08/05/0013.03:21 Run Code: 965480601 1 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page: IS of 30 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE THE YOUNG RESIDENCE I -$/5/00 SUBTOTAI R -VALUE DESCRIPTION ASSEMBLY NAME Tile/Attic/R,38/G ASSEMBLY Floor OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles TYPE Wall (check one) Membrane, Vapor -Permeable Felt G W X Ceiling / Roof 4 H N FRAMING MATERIAL Wood Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 p Z FRAMING % 10% Framing % 3.86 9 16%(16" o.c. Wall) 2.08 INSIDE SURFACE AIR FILM 12%(24" o.c. Wall) 40.92 14.31 10%(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 6 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.00 8 3.86 9 1.3 2.08 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.2101 0.210 0.060 0.060 0.620 0.620 0.800 0.800 38.0001 11.385 0.450 0.450 0.00 0.00 3.86 0.36- 1.3 2.08 0.6101 0.610 40.92 14.31 RG M 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (BtuW4b) HC (A X B) (BtwT-sf) ' members. [ 0.0244 2.50 0.24 0.60 0.06 .0.35 0.02 1.42 0.29 0.41 0.00 0.00 0.00 3.86 0.36- 1.3 2.08 0.26 0.54 g g TOTAL HC 3.0 `NOTE; Wei ht and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0244 X 0.90 ] + [ 0.0699 1 X 0.10 I 1 1 Rc 1- (Fr-/. 1100) 11 Rf Fr0/61100 ASSEMBLY U VALUE I EneravPro 2.1 By EnrecivSoft User Number: 2366 Job Number: 00046 Paw: 16 of 30 1 PROPOSED CONSTRUCTION ASSEMBLY €N1F-3 PROJECT NAME DATE THE YOUNG RESIDENCE ,8/5/00 SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY Tile/R-38/G 2X12 Floor Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 plywood TYPE (check one) Wall 5 Gypsum or Plaster Board LU 0.41 7 X Ceiling I Roof 8 2.08 9 W INSIDE SURFACE AIR FILM 0.610 1 40.12 � o � FRAMING MATERIAL Wood 0 Z FRAMING % 10 % Framing % 9.91 TOTAL HC 3 0 15%(16" o.c. Wall) 12% (24" o.c. Wall) 10%.(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Cell.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 plywood 4 Insulation, Mineral Fiber, R-38 5 Gypsum or Plaster Board 6 0.41 7 0.36 8 2.08 9 0.54 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.2101 0.210 0.060 0.060 0.620 0.620 38.000 11.385 0.4501 0.450 0.41 3.86 0.36 1.39 2.08 0.26 0.54 0.610 0.610 1 40.12 13.51 KC KT 'HEAT CAPACITY (Optional)" WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu1F4b) HC (A X B) (Btu(F-sf) members. [ 0.0249 2.501 0.24 0.60 0.06 0.35 0.02 1.42 0.29 0.41 3.86 0.36 1.39 2.08 0.26 0.54 9.91 TOTAL HC 3 0 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0249 X 0.90 ] + [ 0.0740 X F 0.10 1 I Rc 1- (Fr%1100) 11 Rf Fr%1100 ASSEMBLY U -VALUE I EnergyPro 2.1 By EnregySoft User Number: 2366 Job Number: 00048 Page:17 of 30 1 PROPOSED CONSTRUCTION ASSEMBLY .ENV 3 PROJECT NAME DATE THE YOUNG RESIDENCE I ,V5f00 " THICK- NESS kMING (in.) ❑ 0.625 ❑ 0.010 ® 5.500 ❑ 0.500 El El El SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY R-21 Partition Floor Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 TYPE (check one) XWall 6 2.63 w 0.98 7 Ceiling / Roof 8 11 Rc 9 W Fr%1100 INSIDE SURFACE AIR FILM 0.680 22.92 7.37 NFRAMING MATERIAL Wood 7.41 0 Z FRAMING % 15 % Framing % 16%(16" o.c. Wall) 12% (24" o.c. Wall) 10%(16" o.c. FioorlCeil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Ceil.) THICK- NESS kMING (in.) ❑ 0.625 ❑ 0.010 ® 5.500 ❑ 0.500 El El El SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 4 Gypsum or Plaster Board 6 2.63 6 0.98 7 0.26 8 11 Rc 9 11 Rf Fr%1100 INSIDE SURFACE AIR FILM THICK- NESS kMING (in.) ❑ 0.625 ❑ 0.010 ® 5.500 ❑ 0.500 El El El SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.562 0.562 0.060 0.060 21.000 5.445 0.450 0.450 2.63 0.37 0.98 2.08 0.26 .0.54 11 Rc 1 - (Fr°k1100) 11 Rf Fr%1100 0.680 0.680 22.92 7.37 KC KT 0�Ilv 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu1F4b) HC (A X B) (Btu1F-sf) members. 2.601 0.26 0.68 0.06 0.35 0.02 2.63 0.37 0.98 2.08 0.26 .0.54 11 Rc 1 - (Fr°k1100) 11 Rf Fr%1100 ASSEMBLY U -VALUE 7.41 TOTAL HC 2.21 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0436 X 0.85 ] + [ 0.1357 X 0.15 11 Rc 1 - (Fr°k1100) 11 Rf Fr%1100 ASSEMBLY U -VALUE I EnergyPro 2.1 By EnregySoft User Number: 2366 Job Number: 00048 Page:18 of 30 1 PROPOSED CONSTRUCTION ASSEMBLY EAHF4 PROJECT NAME DATE THE YOUNG RESIDENCE I- 18/5/00', SUBTOTAI R -VALUE DESCRIPTION %MING ASSEMBLY NAME ASSEMBLY linterior Air Wall Floor stucco 2 Air Space 3 Gypsum or Plaster Board TYPE (check one) X Wall 6 2.08 G 0.54 7 Ceiling / Roof 8 9 W INSIDE SURFACE AIR FILM 0.680 1 2.33 H N FRAMING MATERIAL Wood 12.1 p Z FRAMING % 15% Framing % 1S%(16" o.c. Wall) 12%(24" o.c. Wall) 10%(16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Cell.) SUBTOTAI R -VALUE DESCRIPTION %MING OUTSIDE SURFACE AIR FILM 1 stucco 2 Air Space 3 Gypsum or Plaster Board 4 0.39 6 2.08 6 0.54 7 Fr%1100 8 9 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS (in.) %MING ❑ © ❑ El El El El 0.170 0.875 3.500 0.500 3.465 0.450 0.450 0.39 0.60 2.08 0.26 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.1701 0.170 0.175 0.175 0.850 3.465 0.450 0.450 0.39 0.60 2.08 0.26 0.54 11 Rf Fr%1100 ASSEMBLY U -VALUE 0.6801 0.680 1 2.33 4.94 KC KT `HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) members. [ 0.4301 8.461 0.20 1.69 1.53 0.39 0.60 2.08 0.26 0.54 11 Rf Fr%1100 ASSEMBLY U -VALUE 12.1 TOTAL HC 2 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.4301 X 0.85 ] + [ 0.2024 X 0.15 1/ Rc 1 - (Fr0/61100) 11 Rf Fr%1100 ASSEMBLY U -VALUE EnergyPro 2.1 By EnregySoft User Number: 2366 Job Number: 00048 Page:19 of 30 1 INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R Site Address Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required; however, use of this form to provide the information is optional.) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Equipment Equip. # of Efficiency' Duct Duct or Heating Heating Type (pkg. CEC Certified Mfr Name Identical (AFUE etc.)) Location Piping Load Cappachy heat pump) & Model Number Systems [>= CF -1 R Va[ue] (attic, etc.) R -Value (Btu/hr) (Btu/hr) Cooling Equipment Equip. CEC Certified Compressor Type (pkg. Unit Mfr Name & heat pump Model Number # of Efficiency' Duct Cooling Coolingg Identical (SEER etc.) Location Duct or Load Cappacity Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr) 1. — reads Greater Than or Equal to. I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner WATER HEATING SYSTEMS: CEC Certified Distribution If Recir- # of Rated2 Tank Effie 2 External Heater Mfr Name Type(Std, culation, Identical Input (kW Volume ciency Standb Insulation Type & Model Number Point -o -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (%S R -Value 2 For small gas storage (rated input of less than or equal to 75,000 Btuthr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input. For instantaneous gas water heaters, list Recovery Efficiency and Rated Input. 3 R-12 e)demal insulation is mandatory for storage water heaters with an energy factor of less than 0.58. Faucets & Shower Heads: All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111. I, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:20 of 30 INSTALLATION CERTIFICATE (Part 2 of 7) CF -6R Site Address FENESTRATION / GLAZING: Permit Number Product U- Product Interior or Value' SHGC' Exteror Shading (=<CF -1 R (=< CF -1 R # of Quantity S9uare Device or Comments/ Manufacturer/Brand Name value) 2 value)' Panes (Optional) Feet Overhanq Special Features GROUP LIKE PRODUCTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 1. Manufactured Fenestration products use the values from the product label. Field Fabricated fenestration products use the default values from Section 116 of the Energy Efficiency Standards. 2. Installed U -value must be less than or equal to values from CF -1R. Installed SHGC must be less than or equal to values from CF -1R, or a shading device (interior, exterior or overhang) Is installed as specified on the CF -1 R. Attematively, installed weighted average LLvalues for the total fenestration area are less than or equal to values from CF -1 R. I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2) is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #s Signature, Date Installing Subcontractor (Co. Name) (if applicable) OR General Contractor (Co. Name) OR Owner OR Window Distributor Item #s Signature, Date (if applicable) Item #s Signature, Date (if applicable) Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:21 of 30 WSTALLATION CERTIFICATE (Part 3 of 7) CF -6R Site Address DUCT DIAGNOSTICS Permit Number This buiding obtained compliance credit for: ❑ Duct sealing ❑ Duct Area Reduction ❑ ACCA Manual D design and installation CREDIT FOR REDUCED DUCT SURFACE AREA OR LOCATION Duct Location' Exterior Measured Surface Area Exterior Surface (CFAR) Area ❑ Attic ❑ Crawlspace ❑ Basement ❑ Other Total ACCA Design ❑ Duct Design on Plans ❑ Installed duct diameters match plans ❑ TXV installed ❑ Access to TXV valve (if installed) ❑ No TXV, Fan air flow (CFM) _ ❑ Duct Leakage Measured ❑ Measured leakage (CFM) HVAC fan air flow (CFM) (measured or calculated as *Ignore ducts in ❑CFM = 0.7 x A floor for CZ 8 through 15 conditioned space. Only a check is ❑ CFM = 0.5 x A floor for CZ 1 through 7 & 16 required for location or, it the equipment size is known, the larger of 1 or 2. credit' 1. ❑ CFM = 400 x Cooling Capacity in Tons or Pa �Y 2. ❑ CFM = 21.7 x Heating Capacity in Thousands of Btu per hour) Leakage divided by HVAC Fan air flow (must be =< 0.06) For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed: ❑ Duct Fan Pressurization at rough - in measured leakage CFM CHECK AFTER FINISHING WALL: ❑ Pressure Pan Test ❑ House pressuezation test ❑ Visual Inspection of Duct Connections Provide Follow-up Test Results or Inspection Results on a Separate Page ❑ This certifies that the ducts surface area and duct locations were verified. When compliance credit is claimed for duct surface area reducitons and duct location improvements beyond those covered by default assumptions, builder employees or subcontractors shall certify that they have verified that the duct surface area and locations match those on the plans and shall indicate the duct surface area in each duct location on the CF6R. ❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date Installing Subcontractor Co. Name) Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:22 of 30 INSTALLATION CERTIFICATE (Part 4 of 7) CF -6R Site Address Permit Number BUILDING ENVELOPE LEAKAGE DIAGNOSTICS This buiding obtained compliance credit for: ❑ Envelope sealing using diagnostic testing (CF -1 R) Needed for Compliance Measured Blowerdoor Test (from CF -1 R) Results -Building Envelope Leakage (CFM @ 50 Pa) -Leakage level equivalent to an SLA of 3.0 from CF -1 R -Minimum Building Leakage equivalent to an SLA of 1.5 from CF -1 R (CFM @ 50 Pa) ❑ Yes ❑ No Is design infiltration less than the SLA 3.0 equivalant (from CF -1 R)? ❑ Yes ❑ No Is mechanical ventilation installed? (Required if design is less than 3.0 SLA) ❑ Yes ❑ No Is measured leakage (without fans operating) less than minimum in the above Table (1.5 SLA from CF -1 R)? ❑ Yes ❑ No Is mechanical supply ventilation installed to assure house pressure does not go below minus 5 Pascal relative to outside ambient with all exhaust fans operating? Mechanical Ventilation - Fill in Table if mechanical ventilation is installed Used for Compliance (from CFA R) -Continuous Mechanical Ventilation (CFM)1 -Continuous Mechanical Supply Ventilation (CFM) Required to maintain -5 Pa if building envelope leakage is less than minimum (see above) -Total Power Consumption of Continuous Mechanical Ventilation (Wafts) 2 ❑ This certifies that the building leakage was verified. Measured Actual When compliance credit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall certify that they have verified that the building leakage level matches that used for compliance on the CF -6R and shall document the infiltration levels required for compliance and the tested infiltration values on the CF -6R.. ❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date Installing Subcontractor (Co. Name) Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy 1. When mechanical ventilation is required, CFM less than 0.047 CFM per square foot of conditioned floor area indicates failure to achieve compliance 2. As determined from label on fan or manufacturers literature. IEnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:23 of 30 INSTALLATION CERTIFICATE (Part 5 of 7) CF -6R Site Address -Permit-Number The following is an explanation of many of the input values required on this form: HVAC SYSTEMS Heating Equipment Type must be one of the following: Furnace: Gas(including Liquefied Petroleum Gases or oil -fired central furnace & space heater Boiler: Gas or oil -fired boiler Pck HeatPum : Packaged central heat pump S IitHeatPum : Split central heat pump RoomHeatPum : Room heat pump Lr Pk HeatPum : Large packaged heat pump (>=65,000 Btu/hr output) Electric: Electric resistance heating (fixed HSPF = 3.413); radiant electric resistance fixed HSPF = 3.55 CombinedH dro: Reference water heater under water heating systems below -CEC Certified Manufacturer Make & Model Number from applicable Commission approved appliance directory. -V of Identical Systems" is for those systems with the same efficiency, duct location, duct R -Value and capacity. -Efficiency from applicable Commission certified appliance directory. -Duct Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none. -Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data. -Heating/Cooling Load refer to Commission approved load calculation procedure. -Heating/Cooling Equipment Capacity from the applicable Commission certified appliance directory. Note: location elevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's literature). Cooling Equipment Type must be one of the following: S litAirCond: Split system air conditioner Pck rCond: Packaged air conditioner S IitHeatPum : Split system heat pump Pck HeatPum : Packaged heat pump RoomHeatPum : Room heat pump LrgPkgHeatPump: Large packaged heat pump (>=65,000 Btu/hr output). Substitute EER for SEER when SEER is not available. RoomAirCond: Room air conditioner. Minimum SEER varies" LrgPkgAirCond: Large packaged air conditioner (>=65,000 Btu/hr output). Substitute EER for SEER when SEER is not available. EvapDirect: Direct evaporative cooling system. For compliance calculation purposes, fixed values: SEER = 11.0; duct location = attic; duct insulation R -value = 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, fixed values: SEER = 13.0; duct location = attic; duct insulation R -value = 4.2 "Refer to California Energy Commission (CEC) publication Appliance Efficiency Regulations, P400-92-029 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page: 24 of 30 INSTALLATION CERTIFICATE (Part 6 of 7) CF -6R Site Address Permit Num�er The following is an explanation of many of the input values required on this form: WATER HEATING SYSTEMS Distribution Systems: Refer to Residential Manual for more details. Standard: Standard - Supply prssure based system, no pumps Pipe Insulation: Pipe Insulation on all 3/4 -inch pipes POU/HWR: Point of Use/Hot Water Recovery System Recirc/NoControl: Recirculation loop with no controls Recirc/Timer: Recirculation loop with a timer Recirc/Tem : Recirculation loop with temperature control Recirc/Time + Temp: Recirculation loop with a timer and temperature control Recirc/Demand: Recirculation loop with demand control Water Heater Type Information Needed FENESTRATION / GLAZING Rated Input No No No No Yes Yes Fenestration: Energy Factor Recovery Efficiency Standby Loss Storage Gas, Oil or Electric Yes No No Heat Pump Yes No No Instantaneous Gas No Yes No Instantaneous Electric Yes No No Large Storage Gas No Yes Yes Indirect Gas (Boiler) No Yes (AFUE) No FENESTRATION / GLAZING Rated Input No No No No Yes Yes Fenestration: Windows, sliding glass doors, french doors, skylights, garden windows, and any door with more than one square foot of glass Operator Type; Slider, hinged, fixed U -Value: Installed U -Value must be less than or equal to value from CF -1 R OR Installed weighted average LI -Value for the total fenestration area is less than orequal to value from CF -1 R SHGC: Installed SHGC must be less than or equal to value from CF -1 R OR Installed SHGC for the total fenestration area is less than or equal to value from CF -1 R OR An interior shading device, overhang, or exterior shading device is installed consistent with the CF -1 R Shading Device: Include when the building complied using an interior shading device: blinds, opaque roller shades, blinds (do not list draperies), an exterior shading device: woven sunscreen, louvered sunscreen, low sun angle sunscreen, roll -down awning, roll -down blinds or slats (do not list bug screen), or an overhang (include depth in feet) EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:25 of 30 INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R Site Address Permit Number The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3 of 6): TYPE OF CREDIT Refer to Residential Manual Chapters 4 and 5 for more details: Reduced Duct Surface Calculated as the outside area of the duct. Areas must be measured and Area: verified by HERS rater. Improved Duct Location: Supply duct located in other than attic, as verified by location of registers (does not require HERS rater verification). Catastrophic Leakage: Pressure pan test reading must be less than 1.5 Pascal at a house pressure of 25 Pascal. TXV: Access cover required to facilitate verification. Infiltration Reduction: Infiltration is measured without mechanical ventilation operating. Mechanical ventilation is required for very tight house construction when credits for infiltration reduction using diagnostic testing are beng used. for achieving compliance. These very tight houses are defined as those with SLA of less than I.S. The compliance documentation (CF -1 R) will contain the measured CFM target value from a blower door test at 50 Pascal pressure difference that represents this SLA of 1.5. Mechanical ventilation is also required if the builder chooses to design the building to use mechanical ventilation and claims a credit for infiltration below an SLA of 3.0. The compliance documentation(CF-1 R) will contain the measured CFM target value that represents this 3.0 SLA. If the builder claims credit in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and the actual measured SLA is 1.5 or greater, then mechanical ventilation is not required. If the SLA in this case were below 1.5, then mitigation (such as mechanical ventilation) would be required. IEnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:26 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THE YOUNG RESIDENCE 8/5/00 SYSTEM NAME FLOOR AREA - LIVING ZONE 3639 NGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Heating System Output per System 89,000 Total Output (Btuh) 178,000 Output (Btuh/sgft) 48.9 Cooling System Output per System 58,000 Total Output (Btuh) 116,000 Total Output (Tons) 9.7 Total Output (Btuh/sgft) 31.9 Total Output (sgft/Ton) 376.4 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sqft) 1.10 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 3, 76,2134 -2,304 1 1,573 59,017 0 3,814 2,951 0 0 0 0 0 0 0 0 3,814 2,951 83,9121 -2,3041 6491 BDP 395CAV060111 /563CO60 92,776 3,485 178,000 Total Adjusted System Output 776 3,485 178,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 69.3°F 65.30F 105.0°F O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 104.30F 4000 cfm ROOMS 70.0 °F 69.3 °F �% Return Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0/73.30F 78.9/61.7°F 78.9/61.70F 55.0/52.9°F O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 55.9/53.30F 4000 cfm 38.4% R.H. ROOMS 78.9/61.7°F 78.0/61.40F �% Return Air Ducts `{ EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:27 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THE YOUNG RESIDENCE 8/5/00 SYSTEM NAME FLOOR AREA MASTER SUITE 1,634 NGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sgft) 43.5 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 28.8 Total Output (sgft/Ton) 417.2 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 0.98 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel .Latent CFM I Sensible 1,282 31,607 -82 744 27,931 O 0 Outside Air 1,580 1,39 0 0 0 0 0 0 0 0 1,580 1,397 34 768 -82 3072 BDP 395CAV048091/563C046 37,588 1,444 7T,000 Total Adjusted System Output 37588 1444 71 000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m Jan 12 am m tream Teperatures at Time of Heatina Peak) 26.0°F 69.2°F 69.2°F 105.0°F Supply Air Ducts O Outside Air 0 cfm 104.2 OF Supply Fan Heating Coil 1600 cfm ROOMS 70.0 °F 69.2 °F Retum Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of CoolingPeak 115.0/73.3°F 78.9/61.8°F 78.9/61.8°F 55.0/53.0°F 30 ;0O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 55.9/53.30F 1600 cfm ROOMS 38.6% R.H. 78.9/61.8 OF 78.0/61.4°F Return Air Ducts c I EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:28 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THE YOUNG RESIDENCE 8/5/00 SYSTEM NAME FLOOR AREA GUEST BEDROOMS 1 & 2 1,058 Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 33.1 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 33.1 Total Output (sgft/Ton) 362.7 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.13 Airflow (cfm/Ton) 411.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 797 19,643 -402 519 19,472 0 982 974 0 0 0 0 0 0 0 0 0 982 1 -974 BDP 395CAV036045/563C036 27,728 1,367 Total Adjusted System Output 27,7281 1367 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 21419 35,000 36;000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.2 OF 69.2°F 105.00F O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 104.2 of 1200 cfm ROOMS 70.0 of 69.2 °F k Retum Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Tem)eratures at Time of Coolina Peak) I 15.0/73.3OF 78.8/61.8OF 78.8/61.8OF i 55.0/53.0OF Outside Air 0 cfm 78.8/61.8 of Supply Fan Cooling Coil 1200 cfm Air n—f, Supply Air Ducts 55.8/53 . 3of 38.9% R. H. rRQQMS 78.0 / 61.6 of EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:29 of 30 VYAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THE YOUNG RESIDENCE 8/5/00 SYSTEM NAME FLOOR AREA - GUEST 3 457 NGINFFRIN(; CHFCKS SYSTFM I nOn Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible BDP 395CAV024045I563CO24 18,208 1,079 35;000 Total Adjusted System Output 18,208 1,079 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.40F 69.40F 105.0°F O Supply Air Ducts Outside Air b, 0 cfm Supply Fan Heating Coil 104.40F 800 cfm ROOMS 69.4 of 70.0 of I 15.0 / 73.3 of �i Outside Air 0 cfm 78.5/61.8 0 F k Retum Air Ducts `S 78.5/61.8OF 78.5/61.8OF 55.0/53.1OF ---&— #-, I Supply Fan Cooling Coil 800 cfm h Retum Air Ducts '41 Supply Air Ducts 55.5/53.30F 39.2% R. H. ROOMS 78.0 / 61.6 of I EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00048 Page:30 of 30 1 REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 _ Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED O REINFORCED CONCRETE UCT. STEEL ASSEMBLY ❑ ❑ POST TENSIONED CONCRETE ❑ ASPHALT��OTHER ^ ❑ REINFORCED MASONRY ❑ FIRE PROOFING 1 'f""�_ Q•'�L•J JOB LOCATION �` l (� C(-- L-A / O ` REPORT SEQUENCE N0. TVefp T,�IjCT UR e- nj,•1 PERMIIN1.00v n DATE �- h ,J DAY OF WEEK MATERIAL DESCRIPTION �jl / ,/� ARCHITECT / - w,s••V Lu\ASSISTANTS IN HRS. CHARGED !Z =C AL.c.J -INSP ENGINEE tr Re S HRS. CHARGED DATE `� 2ECTION CONTRAGENECTOR QJ jot CONTRACTOR WEOe-Aw5.5 eLv3(0 P(V CL. > ITI Co -LS i Wy 3 pQ LCA --(-7 o'v\ a 1AX {iU P ec�-e2s S- IA LL) I t-' COPY SENT TO CLIENT O C NUED ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS, AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. SIGN A URE OF REGISTE D INSPECTOR 13 6 C _U:k� a DATE OF REPORT REGISTER NUMBFR REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE ❑ STRUCT. STEEL ASSEMBLY ❑ POST TENSIONED CONCRETE ❑ ASPHALT ❑ REINFORCED MASONRY ❑ FIRE PROOFING ❑ ❑ OTHER JOB LOCATION ��� I �� �� �0� li�J' REPORT SEQUENCE N0. TYPE UfcjURE ® � PERMIT ryp.a DATE � O DAV OF WEEK MATERIAL DESCRIPTION ARCHITECT � INSPECTnR� T HRS. CHARGED ENGINEER ASSISTANTS HRS. CHARGED INSPECTION DATE GENERAL SUB CONTRACTOR �— CONTRACTOR ST � AMA If Au C4 p COPY SENT TO CLIENT O CON UED ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. SIGN URE OF REGISTERE NSPECTO DATE OF REPORT REGISTER NUMRFR 't-& 7-4 a� I Job Name:42-U� S EYId Date: 4 2cif! Job No. Fab. Shop SA- ( a c64a "Materials and weldments conform to plans and specifications and RISC, and AWS D1.1 Shipping Mark 905 SHEL Special Depucy Insp. JA t .P. SAI M.P. Al Full PM M No IIIIMEWEMMIMI�M� WHIMMER Em IMI�M� mi�� MUNIMEN EmMIEMME1 FAEMWIMI�= 1110MEMEMmiii�i� MENIOMEMEM 11MMENEM 121110MENEM MEMMEMEM MEMMEENMMIMI�M�MHUMEMEM MEMMNEEMMIMI�m "Materials and weldments conform to plans and specifications and RISC, and AWS D1.1 Shipping Mark 905 SHEL Special Depucy Insp. REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED O REINFORCED CONCRETE O STRUCT. STEEL ASSEMBLY ❑ POST TENSIONED CONCRETE ❑ ASPHALT ❑ REINFORCED MASONRY ❑ FIRE PROOFING ❑b OTHER C-�►' JOB LOCATIONrl d1,a A l Cau4� 9 .D v t kTA REPORT SEQUENCE NO. TYPE OF STRUCTURE .o 0-v �s • PERT NO. b� - n(8/0 I DAV OF WEEK MATERIAL DESCRIPTION ARFhyTECT l(�� \ ,,� INTI/ -VI HRS. CHARGED ENGINEER &-Irif-55S ASSISTANTS HRS. CHARGED INSPECTION DATE O GENERAL �-� SUB CONTRACTOR �I.I C�YK ^ t/ �'v� CONTRACTORS � COPY SENT TO CLIENT ❑ CONT != ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT 1 HAVE INSPECTED TO THE BEST OF MN KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. GN UREOF REGISTER SPD,ECT w -r6V l/�l DATE OF REPORT REGISTER NUMBFR i iT 4Y _'�, STRUCTURAL AND CIVIL ENGINEERING DENISE R. POELTLER; INC,. 73.661 Highway 111 • Suite G • Palm Desert, California.92260 2 May 2001. Mr. Tom Hartung, Building Official . CITY OF LA QUINTA 7.8495 Calle Tampico La:Quinta, CA 92253 . -Subject: Structural Observation Project: YOUNG RESIDENCE Address: 78=2.80 Birkdale.Court; The Tradition Dear Mr. Hartung: I-have observed the structural elements and lateral load path for the structure referenced above and .found it to be in conformancewith the structural documents prepared by my firm. In addition,. I observed the placement of steel base plates "and anchor bolts for the steel frames located .on top of the pool. bond beam. . Respectfully, submitted, QROF ES S/n �p 9� Lui No: 33446 9 Denise- R.:Poeltler Exp. 6-30-02. R.C.E. 33446 *��q CIV1- • PF �F CAS\FAQ W.O. 00-172 cc: Jody Jones, ANDREW- PIERCE CORPORATION structlq.wpd (760) 779-0405 .- • FAX (7.60) 779-1317