0105-206 (SFD) Title 24TITLE 24
Energy Conservation
Standards Compliance Report
FERRARI CUSTOM RESIDENCE
LOT 41 -LOT 41 CLARET COVE
LA QUINTA
April 20, 2001 o Job Number: 19910A
CITY OF LA QUINTA Prepared Fora
BUILDING &SAFETY DEPT. ALLING & WCALLUM LTD
APPROVED 45-190 CLUB DRIVE
FOR CONSTRUCTION INDIAN WELLS, CA 92210
760-360-0250
DATE IC1>1 gy
Madlin's
enterprises
®®®®®®®
Catherine M. Madlin, Certified Energy Analyst
Post Office Box 1443 • Palm Springs, CA 92263
760-322-5004 / 323-3644 (fax)
E-mail: CMadlin@aol.com
madlin-'s
enterprises
Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 l 323-3644 (fax) ®®. ®®®
Title 24 Energy Conservation Standards
Compliance Report
This proposed project has been reviewed for compliance with the 1998 State of California
Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design
described in this compliance portfolio is in conformance with the standards as outlined in
the attached compliance forms and documentation.
Date: April 20, 2001
Job Number: 19910A
Prepared For: WALLING & McCALLUM LTD
Project Name: FERRARI CUSTOM RESIDENCE
Project Location: LOT 41 - LOT 41 CLARET COVE - LA QUINTA
Method of Compliance: MICROPAS V5.1 CERTIFIED COMPUTER PROGRAM
Orientation Of Entry: EAST
Certified Energy Analyst
Catherine M. Madlin
NR 98.90-544
r'{ R 98-90.144
rr
CADEC e
Caftmlo Association of QulldkV Energy Cants
v Post Office Box 1443 v Palm Springs, Ca 92263 v
Madlin s
en terpfises
Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) v S ®®®®
Job Name FERRARI CUSTOM RESIDENCE
Job No. / File No. 19910A
Method of Compliance Micropas V5.1 Computer Simulation
Total Conditioned Square Footage 4096 Sq. Ft.
Total Glazing % (Floor/Glass Area Ratio) 29.3%
Insulation: Roof / Ceiling R-38
I Insulation: Walls
R-21
Insulation: Floor - Slab on Grade
None Required
Insulation: H.V.A.C. Ducts/Location
R-4.2 / Attic
Glazing U -Value / Type: Fixed
0.50, Dual Pane, Low E, Aluminum Frame
(Fleetwood or Equal)
Glazing U -Value / Type: Patio
0.54, Dual Pane, Low E, Aluminum Frame
(Fleetwood or Equal)
Glazing U -Value / Type: Skylights
0.94, Dual Domed
Glazing U -Value / Type: French Door
0.85, Dual Pane, Aluminum Frame
(CEC Default Value)
Glazing: Solar Heat Gain Coefficient (Uncoated)
Tinted Glazing - 0.54 SHGC
Glazing: Exterior Shading
Overhangs As Shown
Glazing: Interior Shading
Blinds (Light Colored) - Most Windows
See Form C2R for exact locations.
Thermal Mass Square Footage & %
2086 Sq. Ft. minimum
H.V.A.C. System Type
Gas Heating / Electric Cooling
HVAC System Efficiencies (heating/cooling)
78% AFUE / 12.0 SEER
Domestic Hot Water Heater
(2) 75 Gal. Gas WHs
Energy Factor / Eff. / Standby Loss
0.80 or better recovery efficiency - 75 Gal
R12 Blanket on Tank
Yes
Recirculating Pump for DHW
Yes - All units to have time & temperature
controls
• Post Office Box 1443 v Palm Springs, Ca 92263 v
Madlin's
enteypfises
Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) . V . ®®®
Thermal Mass Schedule
Date: April 20, 2001
Job Number: 19910A
Prepared For: WALLING & McCALLUM LTD
Project Name: FERRARI CUSTOM RESIDENCE
The following mass data was included in the attached Tide 24 calculations to assist this project in demonstrating
compliance with the standards.
One Exposed hard surface over 2086 Entry, living room, dining room, kitchen,
heavyweight concrete slab pantry, laundry, powder room, bath 3,
bath 4, hallway, master bathroom,
fireplace hearth(s)
NOTES:
1. Pursuant to the standards, areas under cabinets and closets are not included in the square footage figure
listed above.
2. The hard surface listed in the description column above may be ceramic tile, vinyl tile, marble, or paint
directly applied to the heavyweight concrete slab.
3. All surfaces covered by carpet, cabinets, or walls are included in the attached calculations as covered
mass.
e Post Office Box 1443 v Palm Springs, Ca 92263 0
Madlin-'s
enterprises
Catherine M. Madlin, Certified. Energy Aiicilyst Y 760-322-5004 / 323-3644 (fax)
Title 24, Compliance Forms
'CERTIFICATE OF COMPLIANCE: RESIDENTIAL
---------------=-----------------------------
---------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41
-Project Address........ LOT 41 CLARET COVE
LA QUINTA
Documentation Author... CATHERINE M. MADLIN
Madlin's Enterprises
P.O. Box 1443
Page 1 CF -1R
---------------------------------
---------------------------------
Date..04/20/01 09:07:21
*******
---------------------
*v5. 10*
******* I Building Permit
Plan Check / DatE
.•••• Palm Springs, CA 92262
760-322-5004 Iield Check/ Da e
Climate Zone...... 15 -F ----
Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
--------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Conditioned Floor Area.....
Building Type ..............
Construction Type ...
Building Front Orientation.
Number of Dwelling Units...
Number of Stories.. .......
Floor Construction Type....
Glazing Percentage.........
Average Glazing U -value....
Average Glazing SHGC.......
Average Ceiling Height.....
4096 sf
Single Family Detached
New
Front Facing 90 deg (E)
1
1
Slab On Grade
29.3 % of floor area
0.54 Btu/hr-sf-F
0.54
11.4 ft
BUILDING SHELL INSULATION
Component
Frame
-------------------------
Cavity
Sheathing Total Assembly
Type
Type
-------
R -value
--------
R -value R -value U -value
----------------------
Location/Comments
------------------------
------------
Wall
Wood
R-21
R-0
R-21 0.059
Door
None
R-0
R-0
R-0 0.330
Roof
Wood
R-11
R-27
R-38 0.025
SlabEdge
None
R-0
R-0
F2=0.760
SlabEdge
None
R-0
R-0
F2=0.510
FENESTRATION
------------
Over-
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
Value
SHGC Shading
Shading
Fins
--------------------
Door
Back (W)
-----
81.0
------
0.540
---------------------
0.540 Blind
--------------
Standard
-----
None
Window
Left (S)
49.5
0.500
0.540 Blind
Standard
Yes
Window
Back (W)
2.5
0.500
0.540 Standard
Standard
None
Window
Back (W)
5.5
0.500
0.540 Standard
Standard
None
Window
Back (W)
2.5
0.500
0.540 Standard
Standard
None
Door
Back (W)
269.5
0.540
0.540 Blind
Standard
Yes
Door
Left (S)
110.0
0.540
0.540 Blind
Standard
None
Door
Back (W)
145.0
0.540
0.540 Blind
Standard
Yes
Window
Right (N)
10.0
0.500
0.540 Standard
Standard
None
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
---------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
-------------------------------------------------------------------------------
Orientation
--------------------
Window Right (N)
Window Right (N)
Window Right (N)
Door Right (N)
Window Right (N)
Window Right (N)
Window Front (SE)
Door Left ( S )
Window Left (SW)
Door Left (S)
Window Left ( S )
Window Left (S)
Door Front E)
Window Right (NE)
Door Front (E)
Window Front (SE)
Window Left (S)
Window Left (S
Window Left (S)
Skylight Horz
Skylight Horz
Skylight Horz
Skylight Horz
Skylight Horz
FENESTRATION
Over -
Area
U-
------------
Area Thickness
Interior
Exterior
hang/
(sf)
Value
SHGC
Shading
Shading
Fins
-----
3.0
------
0.500
------
0.540
---------------
Standard
--------------
Standard
-----
None
3.0
0.500
0.540
Standard
Standard
None
3.0
0.500
0.540
Standard
Standard
None
64.0
0.540
0.540
Blind
Standard
None
1.5
0.500
0.540
Standard
Standard
None
1.5
0.500
0.540
Standard
Standard
None
17.4
0.500
0.540
Blind
Standard
Yes
68.0
0.540
0.540
Blind
Standard
Yes
17.4
0.500
0.540
Blind
Standard
Yes
24.0
0.850
0.540
Blind
Standard
Yes
44.0
0.500
0.540
Blind
Standard
None
44.0
0.500
0.540
Blind
Standard
None
10.0
0.540
0.540
Blind
Standard
None
32.0
0.500
0.540
Blind
Standard
None
64.0
0.540
0.540
Blind
Standard
None
32.0
0.500
0.540
Blind
Standard
None
45.5
0.500
0.54.0
Blind
Standard
Yes
3.8
0.500
0.540
Standard
Standard
None
18.0
0.500
0.540
Blind
Standard
None
4.0
0.940
0.450
None
None
None
8.0
0.940
0.450
None
None
None
8.0
0.940
0.450
None
None
None
4.0
0.940
0.450
None
None
None
4.0
0.940
0.450
None
None
None
Type Exposed
SlabOnGrade
S1abOnGrade
InteriorHorz
Equipment Type
----------------
Yes
No
Yes
Minimum
Efficiency
------------
THERMAL
MASS
------------
Area Thickness
(sf)
(in)
2086
3.5
2010
3.5
250
1.0
HVAC SYSTEMS
------------
Duct
Duct
Location
R -value
Location/Comments
---------------------
Exposed
Covered
Horiz.Tile
Tested Duct ACCA Thermostat
Leakage Manual D Type
Furnace 0.780 AFUE Attic R-4.2 No No Setback
ACSplit 12.00 SEER Attic R-4.2 No No Setback
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
------------------------------------------=-------------------------------------
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM CF -1R
User#¢-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
Tank Type
------------
Large
System
------------
Large
WATER HEATING SYSTEMS
---------------------
Number
Tank
External
in
Energy Size
Insulation
Heater Type Distribution
Type System
Factor (gal)
R -value
Gas Recirc/TimeTemp 2
n/a 75
R-12
WATER HEATING
SYSTEMS DETAIL
-----------=----------------
Standby
Internal Tank
Recovery Rated
Loss
Insulation
Pilot
Efficiency Input
Fraction
R -value
Light
0.80 n/a
0.025
R-n/a
0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-------- --------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
-This building incorporates a High Mass Design.
This building incorporates non-standard Water Heating System
REMARKS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materials without additional compliance calculations.
The installing hvac contractor shall provide the required CF -6R
with the installed hvac equipment model numbers.
A night setback thermostat is required to be installed with the
HVAC systema
The installed plumber shall provide the required CF -6R listing
the water heater model number(s) and certified plumbing
fixtures:
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF -1R
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07.21
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM CF -1R
User#k-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied -is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
Name.... JOHN WALLING
Company. WALLING & McCALLUM
Address. 45190 R.
IND WELL C
Phone... 76 -360-0
License.
Signed..
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
a e
DOCUMENTATION AUTHOR
Name.... CATHERINE M. MADLIN
Company. Madlin's Enterprises
Address.-P.O. Box 1443
Palm Springs, CA 92262
Phone... 760-322-5004
Signed..
W". - 10 m MX,
.. -
Certified Energy Analyst
Catherine M. Madlin
NR 98-90-544
r
rr R 98-90-144
r
C A B E C
California Association of Building Energy Consultants
MANDATORY MEASURES CHECKLIST: RESIDENTIAL(Page >I of 2) MF -1R
Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents
or on this checklist only.
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Building Envelope Measures:
* §150(a): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
* §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal flame walls
(does not apply to exterior mass walls).
* §150(d): Minimum R-13 raised floor insulation in framed Doors.
§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate
no greater than 2.0 er-n/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
✓
§ 116 -IT Fenestration Products, Exterior Doors, and Intiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
/
2. Fenestration products (except field-fabricated)have label with certified U -value, certified Solar Heat
Gain Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped, all joints and penetrations caulked and sealed
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§I50(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards.
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
Y
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilot lights allowed.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
✓
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
✓
§150(i): Setback thermostaton all applicable heating and/or cooling systems.
✓
§1500): Pipe and tank insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feel of pipes closest to water heater tank, non -recirculating systerns, insulated (R-4 or greater)
✓
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12
external insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55° F insulated-
nsulated6.
6.Piping insulated between heating source and indirect hot water tank.
July 1, 1999
MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page2 of 2) MF -IR
Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all pasties as
minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents
or on this checklist only.
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
* §I50(m): Ducts and Fans
1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBG
1997 UMC sections 601 and 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed
entirely within conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant or other
dud closure system that meets the applicable requiremetns of UL181, UL181 A, or UL181B and other
applicable specified tests for longevity given in §150(m)..
2. Exbaust fan systems have back draft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
manually operated dampers.
§114: Pool and Spa Heating Systems and Equipment.
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating
instructions, no electric resistance heating and no pilot light
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
/
continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
Lighting Measures:
§150(k)l.: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40
lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a
switch on a readily accessible lighting control panel at an entrance to the kitchen.
§ I50(k)2.: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an
efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to
this requirement allowed in §150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approve&
July 1, 1999
'COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09.07:21
-Project Address........ LOT 41 CLARET COVE ******* ---------------------
LA QUINTA *v5.10*
Documentation Author... CATHERINE M. MADLIN Buliding Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check / -Date
Palm Springs, CA 92262
760-322-5004 Field Check/Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPASS v5.10 for 1998 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
----------------------------
----------------------------
MICROPAS5 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
----------
Design
----------
Margin =
---------- _
= Space Heating..........
3.93
2.57
1.36 =
= Space Cooling..........
39.65
41.94
-2.29 =
= Water Heating..........
6.96
5.73
1.23 =
_
= Total
--------
50.54
--------
50.24
-------- _
0,.30 =
Building complies
----------------------------------------------------------------
-----------------------------------------------------------------
with Computer
Performance
GENERAL INFORMATION
Conditioned Floor Ar.ea.....
4096 sf
Building Type..............
Single Family Detached
Construction Type .........
New
Building Front Orientation.
Front Facing 90 deg (E)
Number of Dwelling Units...
1
Number of Building Stories.
1
Weather Data Type..........
FullYear
Floor Construction Type....
Slab On Grade
Number of Building Zones...
1
Conditioned Volume.........
46864 cf
Slab -On -Grade Area.........
4096 sf
Glazing Percentage.........
29.3 % of floor area
Average Glazing U -value....
0.54 Btu/hr-sf-F
Average Glazing SHGC.......
0.54
Average Ceiling Height.....
11.4 ft
Y 4
COMPUTER METHOD SUMMARY Page 2 C -2R
--------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
-------------------------------------------------------------------------------
Zone Type
--------------
HOUSE
Residence
Surface
HOUSE
1
Wall
2
Wall
3
Wall
4
Wall
5
Wall
6
Wall
7
Wall
8
Wall
9
Door
10
Roof
BUILDING ZONE INFORMATION
-------------------------
Floor # of Vent Vent Air
Area Volume Dwell Cond- Thermostat Height Area Leakage
(sf) ( cf ) Units itioned Type (ft) ( sf ) Credit
4096
46864
1.00
Yes
Setback 2.0
Standard No
(W)
2
OPAQUE
Left
SURFACES
3
Window
Area
U-
---------------
Insul
Act
Back
Solar
Form 3
Location/
(sf)
------
value
-----
R-val
-----
Azm
---
Tilt
----
Gains
-----
Reference
------------
Comments
----------------
322
0.059
21
90
90
Yes
W.21.2X6.16
Window
726
0.059
21
180
90
Yes
W.21.2X6.16
0.540
409
0.059
21
270
90
Yes
W.21.2X6.16
270
996
0.059
21
0
90
Yes
W.21.2X6.16
90
387
0.059
21
90
90
No
W.21.2X6.16
36
0.059
21
135
90
No
W.21.2X6.16
10
0.059
21
225
90
No
W.21.2X6.16
27
0.059
21
45
90
No
W.21.2X6.16
48
0.330
0
90
90
Yes
None
4068
0.025
38
n/a
0
Yes
R.38.2X4.24
Surface
------------
HOUSE
11 SlabEdge
12 SlabEdge
orientation
PERIMETER LOSSES
----------------
Length F2 Insul Solar
(ft) Factor R-val Gains Location/Comments
--------------------- ----- ----------------------
313 0.760 R-0 No
43 0.510 R-0 No
HOUSE
0.540
0.540
1
Door
Back
(W)
2
Window
Left
(S)
3
Window
Back
W
4
Window
Back
(W)
5
Window
Back
(W)
6
Door
Back
(W)
7
Door
Left
(S
8
Door
Back
(W)
9
Window
Right
(N)
FENESTRATION SURFACES
---------------------
Area U- Act Exterior Shade Interior Shade
(sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC
----- ----- ----- --- ---- -------------- --------------
81.0
0.540
0.540
270
90
Standard/0.76
Blind/0.47
49.5
0.500
0.540
180
90
Standard/0.76
Blind/0.47
2.5
0.500
0.540
270
90
Standard/0.76
Standard/0.68
5.5
0.500
0.540
270
90
Standard/0.76
Standard/0.68
2.5
0.500
0.540
270
90
Standard/0.76
Standard/0.68
269.5
0.540
0.540
270
90
Standard/0.76
Blind/0.47
110.0
0.540
0.540
180
90
Standard/0.76
Blind/0.47
145.0
0.540
0.540
270
90
Standard/0.76
Blind/0.47
10.0
0.500
0.540
0
90
Standard/0.76
Standard/0.68
COMPUTER METHOD SUMMARY Page 3 C -2R
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPASS v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
FENESTRATION SURFACES
OVERHANGS AND SIDE FINS
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area
Area
U-
Act
Rght
Exterior Shade
Interior Shade
Orientation
(sf)
Value
SHGC
Azm
Tilt
Type/SHGC
Type/SHGC
----------------------
10
Window
Right
(N)
-----
3.0
-----
0.500
-----
0.540
---
0
----
90
--------------
Standard/0.76
--------------
Standard/0.68
11
Window
Right
(N
3.0
0.500
0.540
0
90
Standard/0.76
Standard/0.68
12
Window
Right
(N�
3.0
0.500
0.540
0
90
Standard/0.76
Standard/0.68
13
Door
Right
(N)
64.0
0.540
0.540
0
90
Standard/0.76
Blind/0.47
14
Window
Right
(N)
1.5
0.500
0.540
0
90
Standard/0.76
Standard/0.68
15
Window
Right
(N)
1.5
0.500
0.540
0
90
Standard/0.76
Standard/0.68
16
Window
Front
(SE)
17.4
0.500
0.540
135
90
Standard/0.76
Blind/0.47
17
Door
Left
(S)
68.0
0.540
0.540
180
90
Standard/0.76
Blind/0.47
18
Window
Left
(SW)
17.4
0.500
0.540
225
90
Standard/0.76
Blind/0.47
19
Door
Left
(S)
24.0
0.850
0.540
180
90
Standard/0.76
Blind/0.47
20
Window
Left
(S)
44.0
0.500
0.540
180
90
Standard/0.76
Blind/0.47
21
Window
Left
(S)
44.0
0.500
0.540
180
90
Standard/0.76
Blind/0.47
22
Door
Front
(E)
10.0
0.540
0.540
90
90
Standard/0.76
Blind/0.47
23
Window
Right
(NE)
32.0
0.500
0.540
45
90
Standard/0.76
Blind/0.47
24
Door
Front
(E)
64.0
0.540
0.540
90
90
Standard/0.76
Blind/0.47
25
Window
Front
(SE)
32.0
0.500
0.540
135
90
Standard/0.76
Blind/0.47
26
Window
Left
(S)
45.5
0.500
0.540
180
90
Standard/0.76
Blind/0.47
'27
Window
Left
(S)
3.8
0.500
0.540
180
90
Standard/0.76
Standard/0.68
28
Window
Left
(S
18.0
0.500
0.540
180
90
Standard/0.76
Blind/0.47
29
Skylight
Horz
4.0
0.940
0.450
90
0
None/1.
None/1
30
Skylight
Horz
8.0
0.940
0.450
90
0
None/1
None/1
31
Skylight
Horz
8.0
0.940
0.450
90
0
None/1
None/1
32
Skylight
Horz
4.0
0.940
0.450
90
0
None/1
None/1
33
Skylight
Horz
4.0
0.940
0.450
90
0
None/1
None/1
OVERHANGS AND SIDE FINS
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area
Left
Rght
Surface
(sf)
-----
Wdth
-----
Hgth
-----
Dpth
Hght
Ext
Ext
Ext
Dpth
Hght
Ext
Dpth
Hght
-----------
HOUSE
----
----
----
----
----
----
----
----
----
----
2
Window
49.5
4.5
11
4.5
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
6
Door
269.5
24.5
11
6
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
8
Door
145.0
14.5
10
7
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
16
Window
17.4
2.17
8
3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
17
Door
68.0
8.5
8
1.5
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
18
Window
17.4
2.17
8
3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
19
Door
24.0
3
8
3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
26
Window
45.5
7
6.5
1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
.COMPUTER METHOD SUMMARY Page 4 C -2R
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
----------------------------------------------------------------
-I MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
Mass Type
---------------
HOUSE
1 S1ab0nGrade
2 SlabOnGrade
3 InteriorHorz
System Type
-----------------
HOUSE
Furnace
ACSplit
Tank Type
------------
1 Large
System
------------
1 Large
THERMAL MASS
------------
Area Thick Heat Conduct- Surface
(sf) (in) Cap ivity UIMC R -value Location/Comments
2086 3.5 28.0 0.98 4.60 R-0.0 Exposed
2010 3.5 28.0 0.98 1.80 R-2.0 Covered
250 1.0 24.0 0.67 1.70 R-0.0 Horiz.Tile
HVAC SYSTEMS
------------
Minimum Duct Duct Tested Duct ACCA Duct
Efficiency Location R -value Leakage Manual D Eff
---------------------------------------------------------
0.780 AFUE Attic R-4.2 No
12.00 SEER Attic R-4.2 No
WATER HEATING SYSTEMS
---------------------
Number
in Energy
Heater Type Distribution Type System Factor
Gas Recirc/TimeTemp 2 n/a
No
No
Tank
Size
(gal)
75
WATER HEATING SYSTEMS DETAIL
----------------------------
Standby Internal Tank
Recovery Rated Loss Insulation
Efficiency Input Fraction R -value
0.80 n/a 0.025 R-n/a
0.743
0.596
External
Insulation
R -value
R-12
Pilot
Light
0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a High Mass Design.
This building incorporates non-standard Water Heating System
COMPUTER METHOD SUMMARY Page 5 C -2R
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
REMARKS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materials without additional compliance calculations.
The installing hvac contractor shall provide the required CF -6R
with the installed hvac equipment model numbers.
A night setback thermostat is required to be installed with the
HVAC system.
The installed plumber shall provide the required CF -6R listing
the water heater model number(s) and certified plumbing
fixtures.
Madlin -s
enterprises
Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) ® If ® ® 17
H. V.A. C. Load Calculation
'HVAC SIZING Page 1 HVAC
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
-Project Address........ LOT 41 CLARET COVE ******* ---------------------
LA QUINTA *v5..10*
Documentation Author... CATHERINE M. MADLIN Buliding ermi
Madlin's Enterprises
P.O. Box 1443 Plan Check / Date
Palm Springs, CA 92262
760-322-5004 Fieid Check/ a e
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File-19910A3 Wth-CTZ15S92 Program-HVAC SIZING
User#-MP0207 User-Madlin's Enterprises Run-PERMIT CALCULATION
-------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area ................. 4096 sf
Volume.. .. ............ 46864 cf
Front Orientation.......... Front Facing 90 deg (E)
Sizing Location............ PALM DESERT
Latitude. .... ........ 33.7 degrees
Winter Outside Design...... 32 F
Winter Inside Design....... 70 F
Summer outside Desi.gn...... 112 F
Summer Inside Design....... 78 F
Summer Range. ... .. ..... 34 F
Interior Shading Used...... No
Exterior Shading Used...... No
Overhang Shading Used...... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
Heating
Cooling
Description
--------------------------------------------
(Btuh)
(Btuh)
-----------
Opaque Conduction and Solar......
20844
11227
Glazing Conduction ...............
24809
22197
Glazing Solar ....................
n/a
42410
Infiltration .....................
24746
16377
Internal Gain ....................
n/a
3750
Ducts ............................
7040
9596
Sensible Load ....................
77440
105557
Latent Load ......................
n/a
21111
-----------
Minimum Total Load
77440
-----------
126669
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
HVAC SIZING Page 2 HVAC
--------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
---------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
factors when selecting the HVAC equipment.
HVAC SIZING Page 3 HVAC
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09.07.21
---------------------
MICROPASS v5.10 File -19910A3 Wth-CTZ15S92 Program -HVAC SIZING
--------User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------
HEATING LOAD CALCULATIONS
-------------------------
DESIGN CONDITIONS FOR ZONE 'HOUSE':
WINTER DESIGN TEMPERATURES:
InsideTemperature ................................ 70.0 F
Outside Temperature ............................... 32.0 F
DESIGN TEMPERATURE DIFFERENCES
Standard.......................................... 38.0 F
CONDUCTIVE HEAT LOSS:
Description
Wall
Wall
Wall
Wall
Shaded Wall
Shaded Wall
Shaded Wall
Shaded Wall
Door
Root
SlabEdge
SlabEdge
orientation
East
South
West
North
n/a
n/a
n/a
n/a
East
Horizontal
n/a
n/a
CONDUCTIVE TOTALS FOR OPAQUE SURFACES 20844
Double
U -value
West
81.0
Heat
Area
x
(Btu/hr-
1662
TD
Loss
(sf)
------
49.5
sf-F)
-------
-------
(F)
(Btuh)
--------
322.0
X
0.0592
x
38.0
= 724
726.0
X
0.0592
X
38.0
= 1633
409.0
x
0.0592
x
38.0
= 920
996.0
x
0.0592
x
38.0
= 2241
387.0
x
0.0592
x
38.0
= 871
36.0
x
0.0592
x
38.0
= 81
10.0
x
0.0592
x
38.0
= 22
27.0
x
0.0592
x
38.0
= 61
48.0
x
0.3300
x
38.0
= 602
4068.0
x
0.0247
x
38.0
= 3816
313.0
x
0.7600
x
38.0
= 9039
43.0
x
0.5100
x
38.0
= 833
CONDUCTIVE TOTALS FOR OPAQUE SURFACES 20844
Double
Door
West
81.0
x
0.5400
x
38.0 =
1662
Double
Window
South
49.5
x
0.5000
x
38.0 =
941
Double
Window
West
2.5
x
0.5000
x
38.0 =
47
Double
Window
West
5.5
x
0.5000
x
38.0 =
105
Double
Window
West
2.5
x
0.5000
x
38.0 =
47
Double
Door
West
269.5
x
0.5400
x
38.0 =
5530
Double
Door
South
110.0
x
0.5400
x
38.0 =
2257
Double
Door
West
145.0
x
0.5400
x
38.0 =
2975
Double
Window
North
10.0
x
0.5000
x
38.0 =
190
Double
Window
North
3.0
x
0.5000
x
38.0 =
57
Double
Window
North
3.0
x
0.5000
x
38.0 =
57
Double
Window
North
3.0
x
0.5000
x
38.0 =
57
Double
Door
North
64.0
x
0.5400
x
38.0 =
1313
Double
Window
North
1.5
x
0.5000
x
38.0 =
29
Double
Window
North
1.5
x
0.5000
x
38.0 =
29
Double
Window
Southeast
17.4
x
0.5000
x
38.0 =
330
Double
Door
South
68.0
x
0.5400
x
38.0 =
1395
Double
Window
Southwest
17.4
x
0.5000
x
38.0 =
330
HVAC SIZING
Page
4
HVAC
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41
Date..04/20/01
09:07:21
-------------------------------------------------------------------------------
MICROPAS5 v5.10
File -19910A3 Wth-CTZ15S92
Program -HVAC
SIZING
User#-MP0207
User-Madlin's Enterprises
Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
Double
Door
South
24.0
x
0.8500
x
38.0 =
775
Double
Window
South
44.0
x
0.5000
x
38.0 =
836
Double
Window
South
44.0
x
0.5000
x
38.0 =
836
Double
Door
East
10.0
x
0.5400
x
38.0 =
205
Double
Window
Northeast
32.0
x
0.5000
x
38.0 =
608
Double
Door
East
64.0
x
0.5400
x
38.0 =
1313
Double
Window
Southeast
32.0
x
0.5000
x
38.0 =
608
Double
Window
South
45.5
x
0.5000
x
38.0 =
865
Double
Window
South
3.8
x
0.5000
x
38.0 =
71
Double
Window
South
18.0
x
0.5000
x
38.0 =
342
Double
Skylight
Horizontal
4.0
x
0.9400
x
38.0 =
143
Double
Skylight
Horizontal
8.0
x
0.9400
x
38.0 =
286
Double
Skylight
Horizontal
8.0
x
0.9400
x
38.0 =
286
Double
Skylight
Horizontal
4.0
x
0.9400
x
38.0 =
143
Double
Skylight
Horizontal
4.0
x
0.9400
x
38.0 =
143
CONDUCTIVE TOTALS FOR GLAZING SURFACES 24809
.INFILTRATION: (Type: Medium)
46864 cuft x 0.77 ac/hr x 0.018 Btu/cuft-F x 38.0 = 24746
SUBTOTAL 70400
DUCT HEAT LOSS: Duct Location; Attic 0.10 x 70400 = 7040
TOTAL HEATING LOAD: 77440
COOLING LOAD CALCULATIONS
-------------------------
DESIGN CONDITIONS FOR ZONE 'HOUSE':
SUMMER DESIGN CONDITIONS:
InsideTemperature ................................ 78.0 F
Outside Temperature...............................112.0 F
TemperatureRange ................................. 34.0 F
DESIGN EQUIVALENT TEMPERATURE DIFFERENCES
Standard. ....•.................................. 34.0 F
Frame Walls and Doors ... ......................... 32.6 F
Ceiling Under Vented Attic ........................ 53.0 F
Frame Partitions .................................. 24.0 F
CONDUCTIVE HEAT GAIN: U -value Heat
Area (Btu/hr- TDeq Gain
Description Orientation (sf) sf-F) (F) (Btuh)
------------------------------------- ----------------------------
HVAC SIZING
Door
West
81.0
Page 5
HVAC
Project Title.......... WALLING.FERRARI.LOT41
34.0 =
Date..04/20/01
09:07:21
MICROPAS5 v5.10
File -19910A3
Wth-CTZ15S92
x
Program -HVAC SIZING
x
User#-MP0207
-------------------------------------------------------------------------------
User-Madlin's
Enterprises
Run -PERMIT CALCULATION
West
Wall
East
322.0
x
0.0592 x 32.6 =
622
Wall
South
726.0
x
0.0592 x 32.6 =
1401
Wall
West
409.0
x
0.0592 x 32.6 =
789
Wall
North
996.0
x
0.0592 x 32.6 =
1922
Shaded Wall
n/a
387.0
x
0.0592 x 24.0 =
550
Shaded Wall
n/a
36.0
x
0.0592 x 24.0 =
51
Shaded Wall
n/a
10.0
x
0.0592 x 24.0 =
14
Shaded Wall
n/a
27.0
x
0.0592 x 24.0 =
38
Door
East
48.0
x
0.3300 x 32.6 =
516
Roof
Horizontal 4068.0
x
0.0247 x 53.0 =
5322
CONDUCTIVE TOTALS FOR OPAQUE SURFACES 11227
Double
Door
West
81.0
x
0.5400
x
34.0 =
1487
Double
Window
South
49.5
x
0.5000
x
34.0 =
842
Double
Window
West
2.5
x
0.5000
x
34.0 =
42
Double
Window
West
5.5
x
0.5000
x
34.0 =
94
Double
Window
West
2.5
x
0.5000
x
34.0 =
42
Double
Door
West
269.5
x
0.5400
x
34.0 =
4948
Double
Door
South
110.0
x
0.5400
x
34.0 =
2020
Double
Door
West
145.0
x
0.5400
x
34.0 =
2662
Double
Window
North
10.0
x
0.5000
x
34.0 =
170
Double
Window
North
3.0
x
0.5000
x
34.0 =
51
Double
Window
North
3.0
x
0.5000
x
34.0 =
51
Double
Window
North
3.0
x
0.5000
x
34.0 =
51
Double
Door
North
64.0
x
0.5400
x
34.0 =
1175
Double
Window
North
1.5
x
0.5000
x
34.0 =
26
Double
Window
North
1.5
x
0.5000
x
34.0 =
26
Double
Window
Southeast
17.4
x
0.5000
x
34.0 =
295
Double
Door
South
68.0
x
0.5400
x
34.0 =
1248
Double
Window
Southwest
17.4
x
0.5000
x
34.0 =
295
Double
Door
South
24.0
x
0.8500
x
34.0 =
694
Double
Window
South
44.0
x
0.5000
x
34.0 =
748
Double
Window
South
44.0
x
0.5000
x
34.0 =
748
Double
Door
East
10.0
x
0.5400
x
34.0 =
184
Double
Window
Northeast
32.0
x
0.5000
x
34.0 =
544
Double
Door
East
64.0
x
0.5400
x
34.0 =
1175
Double
Window
Southeast
32.0
x
0.5000
x
34.0 =
544
Double
Window
South
45.5
x
0.5000
x
34.0 =
774
Double
Window
South
3.8
x
0.5000
x
34.0 =
64
Double
Window
South
18.0
x
0.5000
x
34.0 =
306
Double
Skylight
Horizontal
4.0
x
0.9400
x
34.0 =
128
Double
Skylight
Horizontal
8.0
x
0.9400
x
34.0 =
256
Double
Skylight
Horizontal
8.0
x
0.9400
x
34.0 =
256
Double
Skylight
Horizontal
4.0
x
0.9400
x
34.0 =
128
Double
Skylight
Horizontal
4.0
x
0.9400
x
34.0 =
128
CONDUCTIVE
TOTAL FOR
GLAZING
SURFACES
22197
HVAC SIZING Page 6 HVAC
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -HVAC SIZING
User#k-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION
-------------------------------------------------------------------------------
SOLAR HEAT GAIN: Note: SCapprox = SHGC /
Description
Double Door
Double Window
Double Window
Double Window
Double Window
Double Door
Double Door
Double Door
Double Window
Double Window
Double Window
Double Window
Double Door
Double Window
Double Window
Double Window
Double Door
Double Window
Double Door
Double Window
Double Window
Double Door
Double Window -
Double Door
Double Window
Double Window
Double Window
Double Window
Double Skylight
Double Skylight
Double Skylight
Double Skylight
Double Skylight
0.87
Area
Orientation (sf) SHGF
West
81.0
x
73
South
49.5
x
32
West
2.5
x
73
West
5.5
x
73
West
2.5
x
73
West
269.5
x
73
South
110.0
x
32
West
145.0
x
73
North
10.0
x
15
North
3.0
x
15
North
3.0
x
15
North
3. 0-
x
15
North
64.0
x
15
North
1.5
x
15
North
1.5
x
15
Southeast
17.4
x
62
South
68.0
x
32
Southwest
17.4
x
62
South
24.0
x
32
South
44.0
x
32
South
44.0
x
32
East
10.0
x
73
Northeast
32.0
x
48
East
64.0
x
73
Southeast
32.0
x
62
South
45.5
x
32
South
3.8
x
32
South
18.0
x
32
Horizontal
4.0
x
152
Horizontal
8.0
x
152
Horizontal
8.0
x
152
Horizontal
4.0
x
152
Horizontal
4.0
x
152
Shading
Coeff.
SCapprox
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644.
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.644
x 0:644
x 0.644
x 0.644
x 0.644
x 0.644
x 0.537
x 0.537
x 0.537
x 0.537
x 0.537
Heat
Gain
(Btuh)
3808
1020
115
259
115
12669
2267
6816
97
29
29
29
618
14
14
693
1401
693
495
907
907
470
989
3009
1278
938
77
371
326
653
653
326
326
EXTERIOR SOLAR TOTAL (Sext) 42410
INFILTRATION: (Type: Medium)
46864 cuft x 0.57 ac/hr x 0.018 Btu/cuft-F x 34.0 = 16377
INTERNAL GAIN (Ig): 1.00 x ( 6 x 225.0 + 2400) = 3750
Dwelling Units People Appliance --------
SUBTOTAL 95961
x
HVAC SIZING Page 7 HVAC
-------------------------------------------------------------------------------
Project Title.......... WALLING.FERRARI.LOT41 Date..04/20/01 09:07:21
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS5 v5.10 File -19910A3 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION '
--------------------------------------------7----------------------------------
DUCT HEAT GAIN: Duct Location: Attic 0.10 x 95961 = 9596
LATENT LOAD:
TOTAL HOURLY SENSIBLE HEAT GAIN 105557
0.20 x 105557 = 21111
TOTAL COOLING LOAD 126669
Madlin's
enterprises
Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 l 323-3644 (fax) JVW IVW IVW T IVW
Manufacturer's Specifications
Catherine M. Madlin, Cede fzed Energy Analyst Y 760-322-5004 / 323-3644 (fax)
Madlin 's
enterprises
VVYVVVV
1998 Title 24 Energy Standards Table Reprint
Table 2-6. Default Fenestration Product U -Values
(this table to be used by manufacturer's to establish a U -value rating
without performance testing)
Single Paneruble Pane
Frame Typed Product Type U -value U-value2
Metal
Operable
1.28
0.87
Metal
Fixed
1.19
0.72
Metal
Greenhouse/Garden window
. 2.26
1.40
Metal
Doorssc
1.25
CM
Metal
SkylightX
1.72
0.94
Metal, Thermal Break
Operable
0.71
Metal, Thermal Break
Fixed
0.60
Metal, Thermal Break
Greenhouse/Garden window
1.12
Metal, Thermal'Break
Doors
0.64
Metal, Thermal Break
Skylight
0.80
Non -Metal
Operable
0.99
0.60
Non -Metal
Fixed
1.04
0.57
Non -Metal
Doors
0.99
0.55
Non -Metal
Greenhouse/Garden windows
1.94
1.06
Non -Metal
Skylight
1.47
0.68
1. Metal includes any field -fabricated product with metal cladding. Non-metal framed
manufactured- fenestration products with metal cladding must add 0.04 to the listed U_
value. Non -Metal frame types can include metal fasteners, hardware, and door thresholds.
Thermal break product design characteristics are:
a. The material used as the thermal break must have a thermal conductivity of not
more than 3.6 Btu-inch/hr/ft2/°F,
b The thermal break must produce a gap of not less than 0.210", and
c All metal members of the fenestration product exposed to interior and exterior air
must incorporate a thermal
break meeting the criteria in (a) and (b) above. In addition, the fenestration product
must be clearly labeled by the manufacturer that it qualifies as a thermally broken
product in accordance with this standard.
2. For all dual glazed fenestration products, adjust the listed U -values as follows:
a. Subtract 0.05 for spacers of 7/16" or wider.
b. Subtract 0.05 for products certified by the manufacturer as low -E glazing.
C. Add 0.05 for products with dividers between panes if spacer is less than 7/16" wide.
d. Add 0.05 to any product with true divided lite (dividers through the panes).
• P.O. Box 1443 v Palm Springs, Ca 92263-1443 v E-mail: Cmadlin@aol.com •
PALMS TO PINES GLASS
U VALUES FOR TITLE 24 CALCULATIONS
FLEETWOOD or EQUAL MFG.
Effective 9/22/99
N -MRM
MiSlidingGlass Doors
Mbperable (250Y
-
■ 1 .
-Fixed
■-
1 1 -