Loading...
14-0686 (ELEC) Title 24I BUILDING ENERGY ANALYSIS REPORT I PROJECT: + _ Reserve at the Citrus Lot 9 La Quinta, CA Project Designer: Bassenian Lagoni Architects 2031 Orchard Drive Newport Beach, CA 92660 949.553.9100 Report Prepared by: Gangyi Zhou GMEP Engineers u 4400 Campus Drive Newport Beach, CA 92660 949-752-1612 Job Number: 63090 CITY OF LA QUINTA BUILDING & SAFETY DEPT. Date: APPR < VED 11/21/2013 FOR CONS UCTION DATE Y The EnergyPro computer program has been used to perform the calculations summarized in this compliance rep This p g a 'has-ap-roval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 B Idi gEnergy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-11-21715:55:24 /D: 63090 I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary LA OU PT - �' ��a e° C3 SAFES DE lam �,;�ti•1ST�UCT40 EnergyPro 5.1 by EnergySoft Job Number: ID: 63090 User Number: 8165 1 2 3 11 t d 1 t i 1 1 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Reserve at the Citrus Lot 9 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11/25/2013 Date Project Address La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,61 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity(ft) Features see Part 2 of 5 Status . Wall Wood Framed R-13 2,234 New Roof Wood Framed Attic R-30 3,618 Radiant Barrier New FENESTRATION U- Exterior Orientation Area(fe) . Factor SHGC OverhangSidefins Shades Status Front (N) 259.5 0.310 0.28 none none Bug Screen New Front (N) 96.0 0.310.:r x._,0.28.—.none..., —none —Bug Screen—_--,, New Left (E) 111.0 0.310 f 0.28 none. none Bug Screen New Left (E){ , 24.0 Ir 0.310 0.28 none �--n'one � Bug Screen f, New Rear (S) ,�� 77.5 ,' ; 0.310 0.28 none ; none jr Bug Screen r New 1 Rear (S) _e�lfll 7 rJ48.0' ` t'0.310--- ' •-0.28 none none , - , Bug Screen • l '; New Right (W) 186.5 0.310 0.28 none none Bug Screen New Right (W) 24.0 0.310 0.28 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status 5 T Ducted Ducted Attic, Ceiling Ins, vented _ ,__—�-8.0'77- �w W1*4 "' " F t � x f Fn -r nI�t�a & SAV'E I WATER HEATING L:— ✓ ov t =�' Ot . Type Gallons Min. Eff Distribution ONSTRUCTION Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New, BY rr_ EnergyPro 5.1 b En erg Soft User Number. 8165 Run Code: 2013-11-21715:55:24 ID: 63090 Page 1 of 8 Reg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc 1 1 0 i Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 AN PERFORM CE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Reserve at the Citrus Lot 9 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 11112512013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. 77—r r. HERS REQUIRED VERIFICATION ' Items in this section require field testing and/or verification by a certified HERS Rater The'inspe torfmust receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System 5 T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 5 T incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. CITY Or .,���r- EPT' SAFETY D FOR CON -6I Ener Pro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-11-21T15:55:24 ID: 63090 Page 2 of 8 IReg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc IReg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 'Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 t f r 11 1 k-1 s ' Reg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone I Date Reserve at the Citrus Lot 9 ❑ Multi Family ❑ Existing+ Addition/Alteration 111/25/201 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating 4.14 5.15 -1.01 4.49 -0.35 4.05 0.09 4.55 -0.41 Space Cooling 52.16 48.41 3.74 49.29 2.87 50.94 1.21 51.11 1.04 Fans 10.40 10.78 -0.38 10.94 -0.54 11.26 -0.86 11.30 -0.90 Domestic Hot Water 10.08 7.18 2.90 7.18 2.90 7.18 2.90 7.18 2.90 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 76.78 71.53 5.25 71.89 4.88 73.43 3.35 74.14 2.64 Percent Better Than Standard: 6.8% 6.4% 4.4% 3.4 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 802 356 Fuel Available at Site: Natural Gas (E) 828 135 Raised Floor Area: 0 (S) 398 126 Slab on Grade Area: 0 (vv) 1,033 211 Average Ceiling Height: 10.0 Roof 3,618 0 Fenestration Average U -Factor: 0.31 TOTAL: 827 Average SHGC: 0.28 Fenestration/CFA Ratio: 22.8% REMARKS 6 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Xxl�' Company GMEP Engineers L�-;�V 11/25/2013 Address 4400 Campus Drive NameGan9iZhou City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 949-752-1612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the -specifications, and with any other calculations submitted with this permit application, and recognizes.that-compl`gnceusing,duct design, duct sealing, verification of refrigerant charge, insulation instal lation=quality`„and building`env '10, installer testing and certification and field verification by an approved HERS rater'.; �,C aljng require Sp,FE Designer or Owner (per Business & Professions Code) gU1LD1N� =�0 �U�tj�ON �►�� Company BassenianLagoniArchitects FOFJCONSTR Address 2031 Orchard Drive Name City/State/Zip Newport Beach, CA 92660 Phone 949.553.9100 BY License* #� Date DATE -Signed- Ener Pro 5.1 b Ener Soft User Number: 8165 RunCode: 2013-11-21T15:55:24 ID: 63090 Pa e 3 of 8 Electrqnically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 'Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 t 1 w 1 1 C! CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Reserve at the Citrus Lot 9 Building Type m Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 11112512013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 447 0.102 R-13 0 90 New 4.3.1-A3 First Floor Wall 693 0.102 R-13 90 90 New 4.3.1-A3 First Floor Wall 272 0.102 R-13 180 90 New 4.3.1-A3 First Floor Wall 822 0.102 R-13 2701 90 New 4.3.1-A3 First Floor Roof 3,6181 0.031 R-30 1 0 0 New 4.2.1-A20 First Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 44.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 2 Window 18.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 3 Window 18.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 4 Window 18.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 5 Window _ 18.0 0.310 NFRC 0.28 NFRC 0 New Low E_ l __ First Floor 6 Window' 18.0 0.310 NFRC.,, ". ' 0.28 NFRC + 0 New Low,E " First Floor 7 Window 18.01 0.310 NFRC 0.28 NFRC 0 New . Low E , ` First Floor 8 Window 16.5 '.'0.310 NFRC 0.28 NFRC -7 0 New 'r Low E I First Floor 9 Window 7.0 0.310 NFRC 0.28 NFRC 0 New Low E / First Floor , 10 Window ,7 /36.0 , 0.310 NFRC 0.28 NFRC 4 0 New Low E ' First Floor, 11 Window < 6.0 0.310 NFRC -0.28 NFRC 0 New 1LowE First Floor 12 Window 6.0 0.310 1 NFRC 0.28 NFRC 0 New Low E First Floor 13 Window 6.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 14 Window 6.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 15 Window 6.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 16 Window 6.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Len H t LExt RExt Left Fin Ri ht in Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76�� -r,-r 11 Bug Screen 0.76 r✓ ` , ... S M E 1 y L' f-' ` " I 12 Bug Screen 0.76 1 ;;Ulut Ir71 1 13 Bug Screen 0.76 t-�'�l V r -'.t . 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 1 DATE Ener Pro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-11-21715:55:24 ID: 63090 Page 4 of 8 IReg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc 1 i' 1 n i Electrqnically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Reserve at the Citrus Lot 9 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11112512013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 6.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 18 Window 6.0 0.310 NFRC 0.28 NFRC 0 New Low E First Floor 19 Window 24.0 0.310 NFRC 0.28 NFRC 0 New Low E FR DR First Floor 20 Window 24.0 0.310 NFRC 0.28 NFRC 0 New Low E FR DR First Floor 21 Window y 24.0 0.310 NFRC 0.28 NFRC 0 New ------ Low E FR DR First Floor 22 Window 24.0 0.310 NFRC 0.28 NFRC 0 New Low.E FR DR' r First Floor 23 Window ` 15. 01 0.310 NFRC 1 0.28 NFRC 1 90 New Low E c First Floor 24 Window 16.5 :,'O. 310 NFRC 0.28 NFRC �7 90 New Low E j First Floor 25 Window 16.5 0.310 NFRC 0.28 NFRC 90 New Low E f First Floor . 26 Window ,1 116.5 0.310 NFRC 0.28 NFRC 90 New Low E First Floor 27 Window •' ' 13.5 0.310 NFRC 0.28 NFRC 90 New Low E ? First Floor 28 Window 16.5 0.310 NFRC 0.28 NFRC 90 New Low E First Floor 29 Window 16.5 0.310 1 NFRC 0.28 NFRC 90 New Low E First Floor 30 Window 24.0 0.310 NFRC 0.28 NFRC 90 New Low E FR DR First Floor 31 Window 7.0 0.310 NFRC 0.28 NFRC 180 New Low E First Floor 32 Window 16.5 0.310 NFRC 0.28 NFRC 1801 New Low E First Floor (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hot Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 _Bug Screen 0.76 26 Bug Screen 0.76 l_ J r- L -t-1` " r , pT I 27 Bug Screen 0.76 28 Bug Screen 0.76 K ISU►�-�"' _ e III. 29 Bug Screen 0.76 1 IN, �J k- n � �, ��� ��t M 30 Bug Screen 0.76 NS IF -- ' 31 Bug Screen 0.76 32 JBug Screen 0.76 DATE-� Ener Pro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-11-21T15:55:24 /D: 63090 Pa e 5 of 8 Reg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 'Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 1 1 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Reserve at the Citrus Lot 9 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/25/2013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 18.0 0.310 NFRC 0.28 NFRC 180 New Low E First Floor 34 Window 18.0 0.310 NFRC 0.28 NFRC 180 New Low E First Floor 35 Window 6.0 0.310 NFRC 0.28 NFRC 180 New Low E First Floor 36 Window 6.0 0.310 NFRC 0.28 NFRC 180 New Low E First Floor 37 Window _ 24.0 0.310 NFRC 0.28 NFRC 1 180 New Low E FR DR _ _ First Floor 38 Window' 24.0 0.310 NFRC 0.28 NFRC 180 New Low_E FR DR. ' ' First Floor 39 Window 6.0 0.310 NFRC 0.28 NFRC 180 New Low EFirst Floor 40 Window 8.0 . 0.310 NFRC 0.28 NFRC !`270 New Low E Ij 1 First Floor 41 Window .8.0 0.310 NFRC 0.28 NFRC 270 New Low E ;+ First Floor - 42 Window ,r 116.5. 0.310 NFRC 0.28 NFRC 270 New Low E First Floor, 43 Window -!:! 16.5 0.310 NFRC .0.28 NFRC 270 New 1LowE First Floor 44 Window 16.5 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 45 Window 18.0 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 46 Window 18.0 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 47 Window 16.5 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 48 Window 16.5 0.310 NFRC 0.28 1 NFRC 270 New Low E First Floor (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS. _ ID Exterior Shade Type SHGC Window H t 7 Wd Ove hang Left Fin Right Fin Len H t LEA REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Screen 0.76 43 -Bug Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-11-21T15:55:24 ID: 63090 Page 6 of 8 Reg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc Electrgnically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 'Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 1 fL t U L 77 IJ 1 J 1 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Reserve at the Citrus Lot 9 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11112512013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 49 Window 16.5 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 50 Window 8.0 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 51 Window 27.5 0.310 NFRC 0.28 NFRC 270 New Low E First Floor 52 Window 24.0 0.310 NFRC 0.28 NFRC 270 New Low E FR DR First Floor s (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 77,-, — (1t {IV IJ I I C A �� I v, � ncPrT I a•n 1� :OR BY Ener Pro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-11 '21 -15.55.-24 _ ID:=63090---- - -l- Pae 7 of 8 Reg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc 1 L L 1 J 1 F. t Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 11/25/2013 Electronically Signed at CalCERTS.com by Michael Rafferty (Hearthside Communities LLC) 11/25/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Reserve at the Citrus Lot 9 Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/25/201 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built 5 T 1st FLR 3,618 36,180 Totals 3,6181 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Type Min. Eff. Thermostat Type Status 5 T 1 Central Furnace --Cooling — 80% AFUE Split Air Conditioner 13.0 SEER Setback New y j � HVAC DISTRIBUTION System Name Heating 'Duct Ducts Cooling Duct Location R -Value Tested? Status 5 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Takagi T -K2 1 Instant Gas Kitchen Pipe Ins 199,000 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o Q c G�' 0F� ,, „S stem_Name_Length Pipe,P j - Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑t ❑ 1 ,r-,' :- TRIS — Iviv M Ener Pro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-11-21715:55:24 ID: 63090 Pa e 8 of 8 IReg: 213-N0088594A-000000000-0000 Registration Date/Time: 2013/11/25 13:21:18 HERS Provider: CalCERTS, Inc 1 1 1 1 u t 1 C 1 1 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Reserve at the Citrus Lot 9 Date 11112112013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating=source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. , , �, r-�R m\I ,p §1500)2: Pipe insulation for steam hydronic heating systems or hot water sy'stems:515tipsi, meet" -tiie rbe direments-of Standards Table 123-A. �� .��,. �r, R, SAFE. t ULr 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, a ul - merit maintena cn e; and win, d. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retarda�o�s`enclgsedlentirely in conditioned space. 1 FnR COQ 1 150(j)4: Solar water -heating systems and/or collectors are certified by the Soflar Rating and Certification Corporation. DATE EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-11-21715:55:24 /D: 63090 Page 11 of 13 L 1 r t 1 u 1 1 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Reserve at the Citrus Lot 9 11112112013 § r50(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support plafforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system;. and.all,permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility -rooms are;tiigh efficacy and'confrolled by a manual -on occupant sensor. UA §lu 0(kated erman installed lighting that is internal to cabinets shall use nomoor than 20�watts'-of.power per,iineat foot of .ntly icn FOR CONST RUCTION BY nATF_ .�--� - EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-11-21 T15. -55:24 ------ID 63090 Page 12 of 13 1 1 i 11 1 L i L 1 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Reserve at the Citrus Lot 9 11112112013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for, private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor juminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable re uirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. C► r 1( G LA Q J 9 MITA BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION LS DATE BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-11-21715:55:24 ID: 63090 Page 13 of 13