BRES2016-0209 Title 24Date:
8/12/2016
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 6.7 by EnefgySoft User Number. 8961 ID: 2016-22
- CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Residential Building Calculation Date/Time: 02:59, Fri, Aug 12, 2016 Page 1 of 7
Calculation Description: Title 24 Analysis Input File Name: Podeschi Casita.xml
GENERAL INFORMATION
ENERGY USE SUMMARY -
01
Project Name Residential Building
04
0506.
02
Calculation Description Title 24 Analysis
- 08
Energy Use (kTDV/ft2-yr)
03
Project Location 79020 Calle Brisa
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015 -
06
-Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 225 -
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 817
15
} Number of Zones 1
16
Slab Area (ft2) 817
17
Number of Stories 1 _
18
Addition Cond.- Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (ft2 N/A . :.
21
F Glazing Percentage (%) 15.2% }
COMPLIANCE RESULTS.
V
01 Building Complies wiUi Compute"r'_Performance"""�
02 This building incorporates featuresttthat require field-testing and/orver_ification1by a certified HERS rater uncle* the supervision of a CEC-approved HERS provider.
d i s E 4 +..- - )1 i t. G -. �: 30. _ ; � � 0 a0 — D� i of 4 i :l '•a 3 .. _
03 This building incorporates one or_more Special Features shown below s
.:�� Mme.• ?�-.` � �� , 't.,.�'` � � - .` � • �� -. 1 -
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time.,
2016-08-12 03:13:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- C17111-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08-12 03:02:26
ENERGY USE SUMMARY -
04
0506.
a
07
- 08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.00
1.30
" -0.30.
-30.0%
Space Cooling
134.73
136.10
-1.37
-1.0%
IAQ Ventilation
1.68
1.68
0.00
0.0%
Water Heating
23.04
20.25
2.79
12.1%
Photovoltaic Offset
0.00
0.00
----
Compliance Energy Total
160.45
159.33
1.12
0.7%
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time.,
2016-08-12 03:13:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- C17111-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08-12 03:02:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Residential Building Calculation Date/Time: 02:59, Fri, Aug 12, 2016 Page 2 of 7
Calculation Description: Title 24 Analysis Input file Name: Podeschi Casita.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ceiling has high level of insulation
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation -
Cooling System Verifications:
• Minimum Airflow
• Verified EER `
• Verified SEER
• Refrigerant Charge. _
• Fan Efficacy Watts/CFM ,. '•!
HVAC Distribution System Verifications:
• Duct Sealing l
Domestic Hot Water System Verifications:
--None --
ENERGY DESIGN RATING T' 'k y +1k Y i R.•
This is the sum of the annual.TDV energyp F ` gy3ti " r " 6h 4 ' ` �` "'
consum tion or4ener use�components included ingherperforItan complOan �e apphoa} h for the Standard Design Building (Energy Budget) and the annual
�
TDV energy consumption for lighting and cromponents-not'regulated by Title•24, Part 6 (such assdomestic appliancesand�consumer-electronics),and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use
Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 234.56 .:
233.44 1.12 s 0.5%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
•04
05
06
07
Project Name -
Conditioned Floor Area (f:2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Residential Building
817
1
2
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Zone 1
Conditioned
HVAC Systeml
817
10
DHW Sys 1
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time: 2016-N-1203:13:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version-,CFSR-04072016-744 Report Generated at: 2016-08-12 03:02:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 02:59, Fri, Aug 12, 2016
Calculation Description: Title 24 Analysis Input File Name: Podeschi Casita.xml
CF1 R -PRF -01
Page 3 of 7
OPAQUE SURFACES
01 02 / #\
03 04 05 06 07 08
Name Construction's
Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Zone 1 'Attic_4RoofZone 1`
_Ventilated - 4 0.1 0.85 Yes No
01
02
03
04
06
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (f:2)
Window & Door Area (ft2)
Tilt (deg)
Front Wall
Zone 1
R-21 Wall
225
Front
270
24
90
Left Wall
Zone 1
R-21 Wall
315
Left
383
74.5
90
Rear Wall
Zone 1
R-21 Wall
45
Back
270
12
90
Right Wall
Zone 1
R-21 Wall
135
Right
383
14
90
Roof
Zone 1
R-49 Roof Attic
---- ----
1
817
0.51
0.65
ATTIC f
01 02 / #\
03 04 05 06 07 08
Name Construction's
Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Zone 1 'Attic_4RoofZone 1`
_Ventilated - 4 0.1 0.85 Yes No
WINDOWS
/
.' �`aa 11(
1 J) IL
01
02
1�•-03WA Ii \� 1 04 ta, $05
J 1]06J'a X07)
08
09.
10
Name
Type
f*
;
Surface (Orientation -Azimuth)
1 Mulltioli
Width (ft) Height (ft), er%
Area
-12
(ft)
U -factor
SHGC
Exterior Shading
Window
Window
Front Wall (Front -225)
---- ----
1
12.0
0.32
0.25
Insect Screen (default)
Window 2
Window
Front Wall (Front -225)
---- ----
1
12.0
0.32
0.25
Insect Screen (default)
GS1
Window
Left Wall (Left -315)
---- ----
1
10.5
0.32
0.25
Insect Screen (default)
GSBath
Window
Left Wall (Left -315)
---- ----
1
4.0
0.51
0.65
Insect Screen (default)
GSBath 2
Window
Left Wall (Left -315)
---- ----
1
4.0
0.51
0.65
Insect Screen (default)
Sitting _
Window
Left Wall (Left -315)
---- ----
1
4.0
0.32
0.25
Insect Screen (default)
Sitting 2
Window
Left Wall (Left -315)
-- ----
1
4.0
0.32
0.25
Insect Screen (default)
GS1 FRN
Window
Left Wall (Left -315)
---- ----
1
24.0
0.32
0.25
Insect Screen (default)
GS2 FRN
Window
Left Wall (Left -315)
---- ----
1
24.0
0.32
0.25
Insect Screen (default)
Sitting 3
Window
Rear Wall (Back -45)
---- ----
1
12.0
0.32
0.25
Insect Screen (default)
GBath2
Window
Right Wall (Right -135)
----
1
6.0
0.32
0.25
Insect Screen (default)
GBed2
Window
Right Wall (Right -135)
---- ----
1
4.0
0.32
0.25
Insect Screen (default)
GBed2 2
Window
Right Wall (Right -135)
---- ----
1
4.0
0.32
0.25
Insect Screen (default)
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time: 2016-08-12 03:13:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-08-12 03:02:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Residential Building Calculation Date/Time: 02:59, Fri, Aug 12, 2016 Page 4 of 7
Calculation Description: Title 24 Analysis Input File Name: Podeschi Casita.xml
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04 .
05
06
07
Building Envelope Air Leakage CFM50
Not Required
'Not Required
Not Required
Total Cavity
Winter Design
Input Rating
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers -
40000-Btu/hr
0
0
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofZone 1
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
"
Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
' `
• Exterior Finish: Wood
R-21 Wall
Exterior Walls -
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21-
0.066
Siding/sheathing/decking -
Inside Finish: Gypsum Board
Ceilings below
9 (
�.-
Cavi /Frame: R-9.1 /2x4
R-49 Roof Attic
attic) .4 .1
Wood Framed Ceiling
2x4 @ 24 in. O.C. -
R 49
0.020
Over Floor Joists: R-39.9 insul.
SLAB FLOORS, k -
01 wv.r��02 _y r. 03 04 05 06 07
Name Zone,�'Area (ftz)1 P_enmeter (ft) EdgeJnsul. R -value 8 Depth Carpeted Fraction Heated
. tY + .�
Slab 81Z6�.30kF 11 None 0.8 No
BUILDING ENVELOPE -HERS VERIFICATION
p' ��-y �{� �y
4 49,.9 +ll-;� iS" R
p, .
lk
03
04
05
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage CFM50
Not Required
'Not Required
Not Required
WATER HEATING SYSTEMS
01 02 03 04 05 06:
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/1 DHW Standard DHW Heater 1 1 •0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
40
0.65
40000-Btu/hr
0
0
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time: 2016-08-12 03:13:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-08-12 03:02:26
r
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 02:59, Fri, Aug 12, 2016
Calculation Description: Title 24 Analysis Input File Name: Podeschi Casita.xml
CF1 R -PRF -01
Page 5of7
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
Cooling Component 1
-HVAC Fan 1 -
Air Distribution System�i
Name
r
System Type
;
EER g- SEER
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type , .
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cooling Component 1:Heating Component 1:Air
Distribution System 1:HVAC Fan 1:1•
Other Heating and Cooling
'System -
Heating Component 1"
Cooling Component 1
-HVAC Fan 1 -
Air Distribution System�i
HVAC - HEATING .UNIT TYPES -
011. 02' 03
Name _J r.=f Type _ Efficiency
.-
Heating Compo 4,11 Cn!ffurnace =fuel -fired central furnace 80 AFUE ,
t, _.rte .,.�� :ua� i`$ ..�'..
tf ` qgg1 y
HVAC -COOLING UNIT TYPES _451 11
01
02
03 04
05
06
07 -.
Name
VerifiedAirflow '' _
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
_ • r
it . ' �,...., . � Effic encyM'.' �
Required
Required
'x
Name
r
System Type
;
EER g- SEER
Zonally Controlled .
- , Multi -speed
Compressor
HERS Verification
7
Cooling. Component 1
�, % ' SplitAirCond -
�
; = 12.2.
16 , _
Not Zonal
~Sin • Speed to
Cooling Componentgle
�
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
VerifiedAirflow '' _
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required -
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1 -hers -dist
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time: 2016-08-12 03:13:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-04072016-744 Report Generated at: 2016-08-12 03:02:26
CERTIFICATE OF COMPLIANCE —RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 02:59, Fri, Aug 12, 2016
Calculation Description: Title 24 Analysis Input File Name: Podeschi Casita.xml
CF1 R -PRF -01
Page 6 of 7
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried ,
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
r0_
HVAC -FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan. 0.58 HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 f t1 02 03,
" Name ;...... ,, J Verified Fan Watt Draw ` Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-66rs-_fan __ �,, - �=' �"°� Required0.58
s- - — t
IAQ (Indoor Air Quality) FANS
01
lt02 �V
' U 0031 '
0'4' va s
05
06
Dwelling Unit
IAQ CF
IAQ Watts/CFM '
�' .
IAQ`Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
30.67
0.25
Default
r0_
Required- -, '
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation DatefTime: 02:59, Fri, Aug 12, 2016
Calculation Description: Title 24 Analysis Input File Name: Podeschi Casita.xml
CF1 R -PRF -01
Page 7 of 7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
JORGE GARCIA
Company:
Signature Date:
JORGE GARCIA DESIGN ASSOCIATES _;
2016-08-12 03:13:57
Address:
CEA/HERS Certification Identification (If applicable):
45175 PANORAMA DRIVE SUITE E
City/State/Zip:
Phone: -
Palm Desert, CA 92260
760-272-.9222
RESPONSIBLE PERSON'S DECLARATION STATEMENT -
I certify the following under penalty of perjury,. under the laws of the State of California:
1. I am eligible under Division 3 of the Business`and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 4Z• "
2. 1 certify that the energy features and perfor'rnance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations:,..
3. The building design features or system design features identified on`this Certificate of Compliance are consistent with the information provided on other applicable. compliance documents,
worksheets, calculations, plans and specifications submittedd 6 -the enforcement.agenc y for approval with this.building permit application.
Responsible Designer Name: r
JORGE GARCIA��
Responsible besigner Signature: -
Company:
GARCIA,DESIGN ASSOCIATES
Date Signed,
'
JORGE
2016-08-12 03.13:57 r
Address:
License: ti
45175 PANORAMA DRIVE SUITE E
n/a "
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-272-9222. ,
L
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information. -
Registration Number: 216-N0270444B-000000000-0000 Registration Date/Time: 2016-08-12 03:13:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-08-12 03:02:26
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Podeschi Casita
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/12/2016
Project Address
79020 Calle Brisa La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
817
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavi (ft) Special Features
Status
Wall Wood Framed R 21 1,182
New
Roof Wood Framed Attic R 49 817
New
Slab Unheated Slab-on-Grade - no insulation 817 Perim = 130'
New
FENESTRATION fTotal Area: 125 Glazing Percentage: 15-2%New/Altered Average U-Factor.
Orientation Area(ff2) U-Fac SHGC Overhang Sidefins Exterior Shades
0.33
Status
Front (StM 24.0 0.320
0.25 none none Bug Screen
New
Left (NKK 66.5 0.320 0.25 none none Bug Screen
New
Left (NIM 8.0 0.510 0.65 none none Bug Screen
New
Rear (NE) 12.0 0.320 0.25 none none Bug Screen
New
Right (SE) 14.0 0.320 0.25 none none Bug Screen
New
HVAC SYSTEMS
City. Heatin Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value
Status
HVAC System Ducted
Ducted Attic 8.0
New
WATER HEATING
-Qty. Type Gallons Min. Eff Distribution
Status
1 Small Storage Gas 40
0.65 Standard
New
EnerqYPro 6.7 by EnerqvSoft User Number. 8961
RunCode: 2016-08-12703:15:14 ID: 2016-22
Pae 10 of 16
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
rmmnliance annrnarh used. Frrentionc may annly. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the C172R.
§ 110 8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF] R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class It vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)I:
walls, vented attics and unvented attics with air -permeable insulation.
§ 150.0(8)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § I10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)I -
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)]A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)28:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
§150.00)2C:
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)]:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have -a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
§ 110.4(b)1:
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
§ 110.4(b)3:
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)1C:
§130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20.kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ I50.0(k)2A:
high efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if- it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ I50.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
' 200 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, §130.0, § 130.2, § 130.4, § 140.7 and §141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in §110.9, §130.0, §130.2, 130.4, 140.7 and 141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable re uirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, §130.0, §130.1, § 130.4, §140.6, and § 141.0.
in a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §110.10 b through §110.10(c).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Podeschi Casita
Date
8/12/2016
System Name
HVAC System
Floor Area
817
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 491
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 88,000
9,773
979
299
11,364
Total Output (Btuh) 88,000
0
Output Btuh/s ft 107.7
564
558
Cooling System
0
0
Output per System 48,000
0
0 0
0
Total Output (Btuh) 48,000
0
979
0
Total Output (Tons) 4.0
564
558
Total Output Btuh/sgft) 58.8
Total Output s ft/Ton 204.3
1 10,901
12,481
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow (cfm)
0
Lennox XC16-048 w/SL280UH090V60 38,938 2,125
88,000
Airflow (cfm/sgft)
0.00
Airflow (cfm/Ton)
0.0
Outside Air (%)
1 0-0%
Total Adjusted System Output 38,938 2,125
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
88,000
Outside Air (cfm/sgft 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfrn
67 OF
67 OF 105 OF
0. ���
Heating Coil 104 OF
ROOM
68 OF
—T—n fl 4.
COOLING
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
76/63°F
76/63°F 55/54°F
Cooling Coil 56 / 54 OF
48.8% ROOM
75/62°F
EnergyPro 6.7 by EnergySoft User Number.- 8961 RunCode: 2016-08-12703:15:14 ID: 2016-22 Page 15 of 16
ZONE •AD SUMMARY
Project Name
Podeschi Casita
Date
811212016
Name
HVAC System
FloorSystem
817
ZONE LOAD SUMMARY
ZONAL..NG
PEAK
•
®®���®Sensible
LOAD)