BRES2016-0293 Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:.
Podeschi House+Cond. Garage
79020 Calle- Brisa
La Quinta, ca 92253.* ,
Project Designer.:
Jorge Garcia Design Associates
45175 PanoramaDr. Suite E '
Palm Desert, CA 92260.
760-272-9222. `
S Report Prepared by:,
Jorge Garcia
'Garcia Design Associates
45175 Panorama Drive Suite E
Palm Desert, CA 92260
760.272.9222
r RE
""EIVED
Job Number:
CITY F LA QUINTA 2016-22G APR 2 2011
BUILDING & SAFETY DEPT.
APPROVED CITY of L,A QuINTA
r
y COMMUNITY DEVELOPMENT
FOR CONSTRUCTION Date:
DA _BY 4/19/2017 '
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed byEnergySoft, LLC—www.energysoft.com.I&&
EnergyPro 6.7 b EnergySoft User Number.' 8961 ID: 2016-22G
rY F71
TABLE OF CONTENTS
Cover Page 1
Table of Contents '_ '' 2
Form CF -1 R -PRF -01-E Certificate' of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
Zone Load Summary' ' . 18
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Input File Name: Podeschi Conditioned Garage 2.xml
CF1R-PRF-01
Pagel of 8
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Residential Building
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 79020 Calle Brisa
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 4423
15
Number of Zones 2
16
Slab Area (ft2) 4423
17
Number of Stories 1
18
Addition Cond. Floor Area 1346
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 1346
21
Glazing Percentage (%) 13.7%
COMPLIANCE RESULTS ` ,= "`• " "
01 Building Complies with Computer Performance" -
02 This building incorporates featuriVhat require field1esting and/orverificatiomby a certified HERS rater under the supervision of a CEC-approved HERS provider.
/ q . st * ow ate. tt it. ,vim
This complian a analysis is valid*only for permit applications through=Deceimber'�39; 2016
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2017-04-19 16:23:56
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.92
1.62
0.30
15.6%
Space Cooling
128.74
127.02
1.72
1.3%
IAQ Ventilation
0.67
0.67
0.00
0.0%
Water Heating
0.00
0.00
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
131.33
129.31
2.02
1.5%
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD - CF1R-PRF-01
Project Name: Residential Building Calculation Date/Time: 16:19, Wed, Apr 19, 2017 Page 2 of 8
Calculation Description: Title 24 Analysis Input File Name: Podeschi Conditioned Garage 2.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• -- None —
HVAC Distribution System Verifications:
• -- None —
Domestic Hot Water System Verifications: F�
• -- None —
ENERGY DESIGN RATING / x
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not by"Title 24, Part 6 (such_ as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. t y
f' •' «' ereRefnce Energy Used Energy Design Rating ; Margin Percent Improvement
v.
Total Energy (kTDV/f2-yr)*169.21 " 167.19 2.02 1.2%
�e M zlik M. ki V I
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Residential Building
4423
1
6
2
0
0
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing House
Conditioned
HVAC Systeml
3077
10
DHW Sys 1
Conditioned Garage
Conditioned
Fujitsu MiniSpliQ
1346
10
1DHW Sys 1
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Input File Name: Podeschi Conditioned Garage 2.xml
CF1R-PRF-01
Page 3 of 8
OPAQUE SURFACES
01
02t'"' .a
03
04
g ;05
07
08
09
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
Front Wall
Existing House
R-13 Wall w/1 EPS
135
Front
600
51.6
90
Existing
No
Left Wall
Existing House
R-13 Wall w/1 EPS
225
Left
600
98.5
90
j Existing
No
Rear Wall
Existing House
R-13 Wall w/1 EPS
315
Back
600
358.3
90
Existing
No
Right Wall
Existing House
R-13 Wall w/1 EPS
45
Right
600
73
90
Existing
No
Roof _
Existing House
R-30 Roof Attic
3077
Existing
No
Garage Front Wall
Conditioned Garage
R-15 Wall w/1 EPS
135
Front
310
90
Altered
N/A
Garage Left Wall
Conditioned Garage
R-15 Wall w/1 EPS
225
Left
390
90
Altered
N/A
Garage Left Wall 2
Conditioned'Garage
R-15 Wall w/1 EPS
45
Right
390
25
90
Altered
N/A
Roof 2
Conditioned Garage
R-38 Roof Attic
1346
New
N/A
ATTIC:�•
01
02t'"' .a
03
04
g ;05
07
08
09
10
Name
r!Gonstruction
T' a
.: YP,
Roof -Rise
IRoof Reflectance
Roof Emittarice
.
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic Existing House
Attic RoofExistinghHouse
V tilated
4
0.1
065
No
No
En9ti
No
Attic Conditioned Garage
Attic RoofConditioned Garage
Ventilated
4
0.1
0.85
No
No
New
No
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Calculation Description: Title 24 Analysis
Input File Name: Podeschi Conditioned Garage 2.xml
CF1 R -PRF -01
Page 4of8
WINDOWS
01
02 03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth) Width(ft)
Multiplie
Height (ft) r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Front Wall (Front -135) ----
----
1
39.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 2
Front Wall (Front -135) ----
1
6.3
0.40
0.36
Insect Screen (default)
Existing
No
Window 3
Front Wall (Front -135) ----
----
1
6.3
0.40
0.36
Insect Screen (default)
Existing
No
Window 4
Left Wall (Left -225) ----
----
1
12.5
0.40
0.36
Insect Screen (default)
Existing
No
Window 5
Left Wall (Left -225) ----
----
1
15.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 6
Left Wall (Left -225) ----
----
1
6.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 7
Left Wall (Left -225) ----
----
1
30.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 8
Left Wall (Left -225) ----
----
1
8.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 9
Left Wall'(Left-225) ----
----
1
15.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 10
Left WaIIJ Left 225 ... ----
----
1
12.0
0.40
0.36 1
Insect Screen (default)
Existing
No
Window 11
Rear Wall Back 315 -
1
6.3
0.40
0.36
Insect Screen (default)
Existing
No
Window 12
Rear Wall .(Back -315)t
80:0
0.40
.,
0.36.
Insect Screen (default)
Existing
No
Window 13
Rear VVafl Back -315
( )
""
1 1
11 0
�0
,<
040 10'.36
Insect Screen (default)
Existing
No
Window 14
'ta."
� Rear Wall (Back -315) -� ---� - T 1
29N0�
-`0 40 ' � 036A'� '
Insect Screen (default)
Existing
No
Window 15
Rear Wall (Back=315) -moo
----• 1 `
10.0 4
t0?40 C
06
Insect Screen (default)
Existing
No
Window 16
Rear Wall (Back -315)
1
10.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 17
Rear Wall (Back -315) ----
----
1
48.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 18
Rear Wall (Back -315) ----
1
25.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 19
Right Wall (Right -45) ----
----
1
33.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 20
Right Wall (Right -45) ----
----
1
15.0
0.40
0.36
Insect Screen (default)
Existing
No
Window 21
Right Wall (Right -45) ----
----
1
12.5
0.40
0.36
Insect Screen (default)
Existing
No
Window 22
Right Wall (Right -45) ----
----
1
12.5
0.40
0.36
Insect Screen (default)
Existing
No
Window 23
Garage Left Wall 2 (Right -45) ----
1
25.0
0.40
0.36
Insect Screen (default)
Existing
No
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Input File Name: Podeschi Conditioned Garage 2.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
240
None
0.8
No
Existing
No
• Cavity/ Frame: no insul. / 2x4 Top Chrd
Conditioned Garage
1346
0.1
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting House
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
R-13 Wall w/1 EPS
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.069
Exterior Finish: R4 Synthetic Stucco
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Floor Joists: R-20.9 insul.
• Cavity / Frame: no insul. 12x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofConditioned Garage
Attic Roofsj4 i
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
R-15 Wall w/1 EPS
Ei(tenor Walls
Wood. Framed Walf
2.4 @ 16 in. O.C.
R 15
0.065
Exterior Finish: R4 Synthetic Stucco
Ceilings (below`
��
�.
Inside Finish: Gypsum Board
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
Wood Framed,
d
2x4@ 24 O.C.
R 38
I,
0.:025
Over Floor Joists: R-28.9 insul.
attic)
Ceiling
m= 3 �
..
,
W
SLAB FLOORS NA M.
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab
Existing House
3077
240
None
0.8
No
Existing
No
Slab -on -Grade
Conditioned Garage
1346
0.1
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Calculation Description: Title 24 Analysis
Input File Name: Podeschi Conditioned Garage 2.xml
CF1R-PRF-01
Page 6 of 8
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
t �7ype
HSPFF//COP Cap 47 Gap ?
Heating System
Cooling System
DuctlessHeatPum Ductless
p
,�>minksplit heat pump �"q
�
8 5
JHeat
60�f
A 21600 ,
.20
13.3
-
1113
Type
Distribution
Fan
Floor Area
Location
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC Systems
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3077
Existing
No
Cooling System
Component 1
Component 1
System 1
1
Fujitsu MiniSplit2
Heat Pump Heating
Heat Pump
No
Heat Pump
No
none -
1346
New
No
and Cooling System
System 2
System 2
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 x CntrlFurnace - Fuel -fired central furnace 78 AFUE
HVAC - HEATING SYSTEMS: Heat Pumps zk*
01
02
04 05
06 07
06
07
Heating..
f—
Cooling
Name
t �7ype
HSPFF//COP Cap 47 Gap ?
SEER EER
Pump System 2
DuctlessHeatPum Ductless
p
,�>minksplit heat pump �"q
�
8 5
JHeat
60�f
A 21600 ,
.20
13.3
HVAC - COOLING SYSTEMS -
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
1113
Type
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
6.0
Attic
Attic
None
Existing
No
N/A
System 1
'specified)
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Calculation Description: Title 24 Analysis Input File Name: Podeschi Conditioned Garage 2.xml
CF1 R -PRF -01
Page 7 of 8
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 1 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
---
--
--- ---
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 66 Default 0 Required
-nc.
aICE ..... .....
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2017-04-19 16:23:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:19, Wed, Apr 19, 2017
Input File Name: Podeschi Conditioned Garage 2.xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
JORGE GARCIA
Company:
Signature bate:
JORGE GARCIA DESIGN ASSOCIATES
2017-04-19 17:54:07
Address:
CEA/HERS Certification Identification (If applicable):
45175 PANORAMA DRIVE SUITE E
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-272-9222
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business'and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. ° x
3. The building design features or system design features identified on this"'Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to,the enforcemennt,,agen�cyfor approvaliwith thFs,building permit application.
Responsible Designer Name: �' '- ```
LIa
Responsible Designer Signature
JORGE GARCIA ,sr
t
,.t
Company: t
Da Sign
2017=04-19 17.54.07
JORGE GARCIA DESIGN ASSOCIATES
Address:
License:
45175 PANORAMA DRIVE SUITE E
N/A
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-272-9222
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-AO11649OB-000000000-0000 Registration Date/Time: 2017-04-19 17:54:07
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
a. a
0
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-04-19 16:23:56
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Podeschi House+Coed. Garage
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
4/19/2017
Project Address
79020 Calle Brisa La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,423
Addition
1,346
# of Units
1
INSULATION
Construction Type
Area
Cavi(ft) Special Features Status
Wall Wood Framed R 13 1,819 Rigid=R-4.0 Existing
Roof Wood Framed Attic R 30 3,077 Existing
Slab Unheated Slab -on -Grade - no insulation 3,077 Perim = 240' Existing
Demising Wood Framed R 13 620 Existing
Wall Wood Framed R 15 1,065 Rigid=R-4.0 Altered
Slab Unheated Slab -on -Grade
no insulation 1,346 Perim = 0' New
Roof Wood Framed Attic R 38 1,346 New
FENESTRATION I Total Area: 606 Glazing Percentage: 13-7%1New/Altered Average U -Factor: 0.00
Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status
Front (SE) 51.6 0.400
0.36 none none Bug Screen Existing
Left (SW) 98.5 0.400
0.36 none none Bug Screen
Existing
Rear (NW) 358.3 0.400
0.36 none none Bug Screen
Existing
Right (NE) 98.0 0.400
0.36 none none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
2 Central Furnace 78% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 20.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic 6.0
Existing
Fujitsu MiniSplit Ductless/with Fan
Ductless n/a n/a
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnerqyPro6.7 by Ene Soft User Number: 8961
Run Code: 2017-04-19T17:53:44 /D: 2016-22G
Pae 11 of 19
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 1 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
§I 10.6(a)5:
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 1 10.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 1 10.8(1) when the
installation of a cool roof is specified on the CFI R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose till insulation shall conform with manuf'acturer's installed design labeled R -value.
§I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(8)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8(g).
150.0 (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e) I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e) I C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§1 10.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
§I50.0(h)1:
in§I50.Oh2.
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
§ 150.0(1):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
§150.OQ)lA:
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
§ 150.0Q)2B:
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ I50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§I50.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§I50.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 1 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§1 10.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, Flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§I50.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§ 150.0(k) I B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k) I C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ I50.0(k) I D:
Ballasts for Fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)I E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)I F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manuf'acturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in ' I50.0(k)2.
§I50.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ I50.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen I ighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §1 10.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
'110.9, '140.7
shall comply with the applicable requirements in § 130.0, § 130.2, §130.4, and ¢141.0.
I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, $130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ I50.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
' ' ' '
nonresidential garages in § 110.9, 130.0, 130. 1, § 130.4, 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the Floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)1213:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 1 10.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January I, 2014,
shall comply with the requirements of § l 10.10 b through § 110.10 e .
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§1 10.10(b)l :
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 1 10.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§I 10.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 1 10.10(c)
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Podeschi House+Cond.
Garage
Date
4/19/2017
System Name
HVAC System
Floor Area
3,077
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 2,076
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
,
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 0
40,459
3,688 853
32,560
Total Output Btuh 0
0
Output Btuhls ft 0.0
2,761
1,878
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btuh 2
0
2,761
1 45,981
3,688
0
Total Output Tons 0.0
1,878
Total Output Btuhls ft 0.0
Total Output s ft/Ton 18,462,000.0
36,316
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Furnace - A/C 2
0
0
Airflow cfmis ft
0.00
Airflow cfm/Ton
0.0
Outside Air %
0-0%
Total Adjusted System Output 2
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
0
Jan 1 AM
Outside Air cfmis ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 OF 105 OF
�-
Heating Coil
104 OF
koom
imp
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
77163 OF
77/63°F 55/54°F
-
Cooling Coil 57 / 55 OF
48.8% Rn. -M Illi
75 / 62 OF
EnergyPro 6.7 by EnergySoft
User Number: 8961 RunCode: 2017-04-19T17:53:44 : ID: 2016-22G Page 16 of 19
6 ,4 .,
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Podeschi House+Cond.
Garage
Date
4/19/2017
System Name
Fujitsu MiniSplit
Floor Area
1,346
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 573
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem
21,600
12,192
1,613 190
7,491
Total Output Btuh
21,600
0
Output Btuhls ft
16.0
0
0
Cooling System
0
0
Output perSystem
18,000
0
0 0
0
Total Output Btuh
18,000
0
1,613
0
Total Output Tons
1.5
01
0
Total Output Btuh/s ft
13.4
Total Output s ft/Ton
897.3
1 12,192
7,491
Air System
CFM perSystem
559
HVAC EQUIPMENT SELECTION
Airflow cfm
559
AOUI8RLXFW/ASUI8RLF18RCLX 15,353 0
13,491
Airflow cfmis ft
0.42
1.8 kW Supplemental Electric
5,973
Airflow cfm/Ton
372.7
Outside Air %
0.0%
Total Adjusted System Output 15,353 0 19,464
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air=
0 cfm
68 OF
68 OF 105 IF 105 OF 105 OF
`_' "` G
L J
Heating Coil Aux. Heat Coil Supply Fan
105 OF
559 cfm
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
75/62°F
75/62°F 55/54°F 55/54°F
Cooling Coil Supply Fan - 55 / 54 OF
559 cfm j
- 49.7% 1 . R0:0M
1 75!62°F
EnergyPro 6.7 by EnergySorf
User Number.- 8961 Run Code: 2017-0419717:53:44 /D: 2016-22G Page 17 of 19
ZONE• , SUMMARY
Project Name
Podeschi. . .Garage
Date
System Name
H VA C System
Floor Area
3,077
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK
Existing House
,. . ,
: of 19
ZONE •AD SUMMARY
Project Name
Podeschi House+Cond. Garage
Date
411912017
—Hoor
System Name
Fujitsu MiniSplit
Area
1,346
ZONE LOAD SUMMARY
COOLINGZONAL SYSTEM
SYSTEM NAME
Conditioned Garage
. ...
EnergyPro 6.7 by EnergySoft User Number: 8961
RunCode: ,. ..
of 19