12-0341 (AR) Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: HANSEN RESIDENCE'S ADDITION 80-370 CAMARILLO WAY LA QUI NTA, CA 92253 Project Designer: GLS Architecture Group Inc. 74491 Joni Dr. Suite # 9 Palm Desert, Ca 92260 760 340.35.28 Report Prepared by: Armando Chavez GLS Architecture Group 74491 Joni Dr. suite # 9 Palm Desert, Ca 92260 760 278.1840 RECEIVED APR 2 7 2012 WN Job Number: 2012 -GLS -005 Date: 4/26/2012 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE " 13y-&- The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by Energ Soft User Number 5553 RunCode: 2012-04-26T17:32:54 ID: 2012 -GLS -005 S ` ' f TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary EnergyPro 5.1 by EnergySoft Job Number: ID: 2012 -GLS -005 User Number: 5553 1 2 3 9 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name HANSEN RESIDENCE'S ADDITION Building Type © Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/26/2012 Project Address 80-370 CAMARILLO WAY LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,64l! Addition 111 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes © No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ftp) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-36 111 Altered Slab Unheated Slab -on -Grade None 111 Perim = 0' New Wall Wood Framed R-19 145 New Roof Wood Framed Attic R-19 2,535 Existing Slab Unheated Slab -on -Grade None 2,535 Perim = 0' Existing Wall Wood Framed R-13 546 Existing FENESTRATION U- Exterior Orientation Area(fF) Factor SHGC Overhang Sidefins Shades Status Rear (NOV) 30.0 0.400 0.35 none none Bug Screen New Right (NE) 197.4 0.710 0.73 none none Bug Screen Existing Front (SE) 85.0 0.710 0.73 none none Bug Screen Existing Rear (NIM 28.0 0.710 0.73 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 79% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HA VC Ducted Ducted Attic, Ceiling+Roof Ins 6.0 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by EnergySoft User Number- 5553 Run Code: 2012-04-26T17:32:54 ID: 2012 -GLS -005 Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name HANSEN RESIDENCE'S ADDITION Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 4/26/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Roof 111 has a U -Factor greater than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by EnerqySoft User Number: 5553 RunCode: 2012-04-26T17:32:54 ID: 2012 -GLS -005 Page 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type 0 Single Family ❑ Addition Alone Date HANSEN RESIDENCE'S ADDITION ❑ Multi Family 2 Existing+ Addition/Alteration 1412612012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 2.23 2.16 0.07 Space Cooling 119.82 117.25 2.57 Fans 20.90 20.44 0.46 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 142.95 139.85 3.10 Percent Better Than Standard: 2.2 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 299 85 Fuel Available at Site: Natural Gas (Svv) 219 0 Raised Floor Area: 0 (NIM 316 58 Slab on Grade Area: 2,646 (NE) 197 197 Average Ceiling Height: 8.0 Roof 2,646 0 Fenestration Average U -Factor: 0.68 TOTAL: 340 Average SHGC: 0.70 Fenestration/CFA Ratio: 12.9% REMARKS ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANYALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the • Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GLS Architecture Group 4/26/2012 Address 74491 Joni Dr. suite # 9 Name Armando Chavez City/State/ZipCity/State/Zip Palm Desert, Ca 92260 Phone 760 278.1840 Sited Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set' of construction documents is consistent with the other compliance forms and worksheets, with the specifications and with any other calculations submitted with this permit application, and recognizes that compliance usi gTouc -ef "'gn, duct sealing, verification of refrigerant charge, insulation installation quality, and building env_elopels ealing Ire installer testing and certification and field verification by an approved HERS rater Rner or Owner (per Business & Professions Code) ypanGLS Architecture Group Inc. Address 74491Joni Dr. Suite # 9 Name Name City/State/Zip Palm Desert, Ca 92260 Phone 760 340.35.28 Signed License # Date Ener Pro 5.1 by Ener Soft User Number 5553 RunCode: 2012-04-26717:32:54 ID: 2012 -GLS -005 Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name HANSEN RESIDENCE'S ADDITION Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family G3 Existing+ Addition/Alteration Date 4/26/2012 OPAQUE SURFACE DETAILS Surface - rype Area U- Insulation Joint Appendix I Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1111 0.025 R-38 0 0 Altered 4.2.1-A21 (E=4.2. 1-A 1) Slab 1111 0.730 None 0 180 New 4.4.7-A1 Wall 811 0.074 R-19 225 90 New 4.3.1-A5 Wall 64 0.074 R-19 315 90 1 New 4.3.1-A5 Roof 2,535 0.049 R-19 0 0 Existing 14.2.1-A4 Slab Z535 0.730 None 0 180 Existing 4.4.7 -Al Wall 0 0.102 R-13 45 90 Existing 4.3.1-A3 Wall 214 0.102 R-13 135 90 Existing 4.3.1-A3 Wall 138 0.102 R-13 225 90 Existing 4.3.1-A3 Wall 1941 0.102 R-13 315 90 Existing 4.3.1-A3 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 30.0 a400 NFRC 0.35 NFRC 315 New 2008PRESCR. WDWZ-15 2 window 8.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear 3 Window 36.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear 4 Window 10.7 0.710 Default 0.73 Default 45 Existing Double Metal Clear 5 Window 64.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear 6 Window 4.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear 7 Window 10.7 0.710 Default 0.73 Default 45 Existing Double Metal Clear 8 Window 64.0 0.710 1 Default 0.73 1 Default 45 Existing Double Metal Clear 9 Window 10.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 10 Window 1.8 0.710 Default 0.73 Default 135 Existing Double Metal Clear 11 Window 1.8 0.710 Default 0.73 Default 135 Existing Double Metal Clear 12 Window 1.8 0.710 Default 0.73 Default 135 Existing Double Metal Clear 13 Window 1.8 0.710 Default 0.73 Default 135 Existing Double Metal Clear 14 Window 15.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 15 Window 15.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 16 Window 4.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Wit Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 lBug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number: 5553 RunCode: 2012-04-26717:32:54 ID: 2012 -GLS -005 Pa e 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name HANSEN RESIDENCE'S ADDITION Building Type ® Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 1412612012 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame I Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 30.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 18 Window 3.8 0.710 Default 0.73 Default 135 Existing Double Metal Clear 19 Window 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 20 Window 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 21 Window 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 22 Window 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 23 Window 1 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 24 Window 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 25 Window 4.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2012-04-26717:32:54 ID: 2012 -GLS -005 Pae 7 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name HANSEN RESIDENCE'S ADDITION Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date 1412612012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area f New Existing Altered Removed Volume Year Built HA VC 111 111 888 2535 2,535 20,280 2004 Totals 111 2,535 0 01 i HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status— tatusHAVC HA VC1 Central Furnace 79 % AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HA VC Ducted Ducted Attic, Ceiling+Roof Ins 6.0 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff � 0 i� 0 N a c System Name Pipe Length Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried 11 Energ Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2012-04-26717:32:54 ID: 2012 -GLS -005 Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name HANSEN RESIDENCE'S ADDITION Date 4/26/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150(a): Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§150(d): Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no olreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling. a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 1506)18: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2012-04-26T17:32:54 ID: 2012-GLS-005 Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date HANSEN RESIDENCE'S ADDITION 4/26/2012 §150(m)1 : All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and. support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1 : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number., 5553 RunCode: 2012-04-26717:32:54 ID: 2012 -GLS -005 Page 10 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date HANSEN RESIDENCE'S ADDITION 4/26/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled,by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 byEnergySoft User Number 5553 RunCode: 2012-04-26T17:32:54 ID: 2012 -GLS -005 Page 11 of 11