BRES2016-0068 Title 24BUILDING ENERGY ANALYSIS
PROJECT:
Jackson Residence
55350 Cherry Hills, PGA West
La Quinta, CA 92253
Project Designer:
Fedderly and Associa
38-747 Nopales Roa
Palm Desert, CA 922
(760) 773-5205
CITY OF LA QUINTA
re
BUILDING & SAFETY DEPT.
d APPROVED
FOR CONSTRUCTION
DATED 63 ,.. BY
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
78818 Velie Way, Suite 8
Palm Desert, CA 92260
(760) 777-0102
Job Number:
Date:
5/23/2016
RECEIVED
MAY 2 7 2016
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
tk a
off
t
+The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
• authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPro 6.7 by EnergySoft User Number: 6712 ID:
i
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Jackson Calculation Daterrime: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Feddedy-16.xmi
CI&RF-01
Page 1 of 13
i
GENERAL INFORMATION
01 Building Complies with Computer Performan` e W"
01
Project Name Jackson
03 This building incorporates one or'more Speciiial Features shown below
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 55350 Chert' Hills, PGA West
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deglCardinal) 20
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 4773
15
Number of Zones 5
16
Slab Area (ft2) 4797
17
Number of Stories 1
18
Addition Cond. Floor Aiea N/A
19
Natural Gas Available Yes
20
Addition Slab Area(ft2) N/A
21
Glazing Percentage (%) 32.9%
COMPLIANCE RESULTS
01 Building Complies with Computer Performan` e W"
02 This buildingincorporates featuresothat require field testin 5 and/orty ficat oin abcertidHERS titer,under the su ervision of a CECa roved HERS provider.
P �.� k qi W4, As r�i ga+r _._ i�ti4 --- M ILi y _ Ji� nw *A 40 *4'�-_ _ P PP
03 This building incorporates one or'more Speciiial Features shown below
05
'K l t" %-00 V tl
3t.." K- F-%
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.49
2.60
-0.11
-4.4%
Space Cooling
104.83
103.71
1.12
1.1%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
5.38
5.99
-0.61
-11.3%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
113.57
113.17
0.40
0.4%
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE@HOD
Project Name: Jackson ulation Date/Time: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis Input File Name: Jackson-Fedderly-16.xm1
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
CF&RF-01
Page 2 of 13
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
•
IAO mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing -
Domestic Hot Water System Verifications: '..
—None —
ENERGY DESIGN RATINGV „ -` --- q
This is the sum of the annual TDV energy consumption for energy use compo nent'sslincluded in the pe f rmance compliance approach for"the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components -not regulatedhl—w, Tt1e=24, Part 6'�(such as domesticl'appliances and ccoonsu erleleciron''i s)'and accounting for the annual TDV energy offset by an
on-site renewable energy system. �.a ' r— P , rz o P fN x / i n sz P
Reference Energy Use " : Energy Design_ Rating.
Margin Percent Improvement
Total Energy (kTDV/f2-yr)' 150.84 150:44':
0.40 0.3%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Jackson
4773
1
5
5
3
1
Registration Number: 216-NO089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Riiilding Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 ReportGenerated at: 2016-05-23 21:09:24
CERTIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE�OD
Project ame: Jackson Calculation Dateffime: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis Input File Name: Jackson-Feddedy-16.xml
CF*RF-01
Page 3 of 13
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg, Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Zone
Conditioned
HVAC 11
992
9
DHW Sys 1
Bedroom 2 & 3 Zone
Conditioned
HVAC 22
794
9
DHW Sys 1
Lounge Zone
Conditioned
HVAC 22
373
9
DHW Sys 1
Living Zone
Conditioned
HVAC 3 & 43
2217
9
DHW Sys 1
Bedroom 4 Zone
Conditioned
HVAC 3 & 43
397
9
DHW Sys 1
�-L TIL
-J h
Iowa* Til. co
J
UWR, In
F,. A low"
HERS PROVIDER,
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Jackson Calculation Datelrime: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Fedderly-16.xml
CF*RF-01
Page 4 of 13
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
20d Wall
Master Zone
R-21 Wall (W.21.2x6.16)
20
Front
70
0
90
110d Wall
Master Zone
R-21 Wall (W.21.2x6.16)
110
Left
180
0
90
200d Wall
Master Zone
R-21 Wall (W.21.2x6.16)
200
Back
336
176.6
90
290d Wall
Master Zone
R-21 Wall (W.21.2x6.16)
290
Right
484
90
90
Roof
Master Zone
R-38 Roof Attic
602
Roof 2
Master Zone
R-38 + R21 Roof Attic
371
20d Wall 2
Bedroom 2 & 3 Zone
R-21 Wall (W.21.2x6.16)
20
Front
360
120
90
110d Wall 2
Bedroom 2 & 3 Zone
R-21 Wall (W.21.2x6.16)
110
Left
200
0
90
200d Wall 2
Bedroom 2 & 3 Zone
R-21 Wall (W.21.2x6.16)
200
Back
195
50
90
290d Wall 2
Bedroom 2 & 3 Zone
R-21 Wall (W.21.2x6.16)
290
Right
350
28
90
Roof 3
Bedroom 2 & 3 Zone
R-38 + R21 Roof Attic
794
20d Wall 3
Lounge Zone
R-21 Wall (W.21.2x6.16)
20
Front
50
0
90
110d Wall 3
Lounge Zone R,°2�VValF(W:21'2x8;16)� fif10
+-� i 14
Left
265
160
90
290d Wall 3
LoungeZone
)*JI R22',`iWall (W 21!2x6)6),
I `2901
14fttitl
90
0
90
Roof 4
Lounge -Zone U i1--W-Roof=Attic1
f ftW
0' U U 'A A 0
373
20d Wall 4
Living Zone
9""
F 21 VVa11 W.21 2x6.16
( )
d rZff
Fro._nt s
348
- 135.797
90
110d Wall 4
Living Zone
R-21 Wall (W.21.2x6.16)
110
Left
732
148
90
200d Wall 3
Living Zone
R-21 Wall (W.21.2x6.16)
200
Back
645
350.8
90
245d Wall
Living Zone
R-21 Wall (W.21.2x6.16)
270
- specify -
192
100
90
290d Wall 4
Living Zone
R-21 Wall (W.21.2x6.16)
290
Right
108
56
90
335d Wall
Living Zone
R-21 Wall (W.21.2x6.16)
335
- specify -
126
65.016
90
Roof 5
Living Zone
R-38 Roof Attic
2217
20d Wall 5
Bedroom 4 Zone
R-21 Wall (W.21.2x6.16)
20
Front
210
0
90
110d Wall 5
Bedroom 4 Zone
R-21 Wall (W.21.2x6.16)
110
Left
160
0
90
200d Wall 4
Bedroom 4 Zone
R-21 Wall (W.21.2x6.16)
200
Back
50
0
90
290d Wall 5
Bedroom 4 Zone
R-21 Wall (W.21.2x6.16)
290
Right
265
88
90
Roof 6
Bedroom 4 Zone
R-38 + R21 Roof Attic
397
Registration Number: 216-N0089085C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-05-23 21:16:32
Report Version - CF1R-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-05-23 21:09:24
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE•HOD
Project Name: Jackson Calculation Date/Time: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis Input File Name: Jackson-Feddedy-16.xml
CIORF-01
Page 5 of 13
SR
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Zone
Attic RoofMaster Zone
Ventilated
3
0.1
0.85
Yes
No
Attic Bedroom 2 & 3 Zone
Attic RoofBedroom 2 & 3
Zone
Ventilated
3
0.1
0.85
Yes
No -
Attic Lounge Zone
Attic Roof -ounge Zone
Ventilated
3
0.1
0.85
Yes
No
Attic Living Zone
Attic RoofLiving Zone
Ventilated
3
0.1
0.85
Yes
No
Attic Bedroom 4 Zone
Attic RoofBedroom 4 Zone
Ventilated
3
0.1
0.85
Yes
No
i,
I LAF
HERS PRO*IDEA
Registration Number:, 216-No089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE C.
Project ame: Jackson Ca culation Date/Time: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Fedderly-16.xm1
C*RF-01 _
Page 6 of 13
WINDOWS
01
02
03
04 05
06
07
08
09
10
Name
Type
Muitipli
Surface (Orientation -Azimuth) Width (ft) Height (ft) er
Area
(ft)
U -factor
SHGC
Exterior Shading
K
Window
200d Wall (Back -200)
- -
1
121.0
0.26
0.23
Insect Screen (default)
L
Window
200d Wall (Back -200)
- -
1
16.0
0.26 1
0.23
Insect Screen (default)
L 2
Window
200d Wall (Back -200)
- -
1
18.0
0.26
0.23
Insect Screen (default)
6
Window
200d Wall (Back -200)
- -
1
21.6
0.29
0.19
Insect Screen (default)
J
Window
290d Wall (Right -290)
- -
1
21.0
0.26
0.23
Insect Screen (default)
J 2
Window
290d Wall (Right -290)
- -
1
21.0
0.26
0.23
Insect Screen (default)
H
Window
290d Wall (Right -290)
- -
1
12.0
0.26
0.23
Insect Screen (default)
G
Window
290d Wall (Right -290)
- -
1
36.0
0.26
0.23
Insect Screen (default)
E
Window
20d Wall 2 (Front -20)
- -
1
56.0
0.26
0.23
Insect Screen (default)
C
Window
20d Wall 2 (Front -20)
- -
1
8.0
0.26
0.23
Insect Screen (default)
D
Window
20d Wall 2 (Front -20)
- -
1
48.0
0.26
0.23
Insect Screen (default)
C 2
Window
20d Wall 2,(Front-20) .,+" �� -
1
8.0
0.26
0.23
Insect Screen (default)
B
Window
200d Wall 2 (Ba6k-2'00) !
y t{
9 1 20.0
0.26
0.23
Insect Screen (default)
B2
Window
200d'`VVall-2 (Back` -200) ,
� � ..
- i
a+ A!
1 I �6.OI
0.26
0.23
Insect Screen (default)
3
Window
'%, 200d Wall -2 (E aLck-20Q)1
*
24.0
0.29
0.19
Insect Screen (default)
F
Window
290d Wall 2 (R6ght-290)
- -
1
-10.0
0.26
0.23
Insect Screen (default)
F 2
Window
290d Wall 2 (Right -290)
- -
1
10.0
0.26
0.23
Insect Screen (default)
C 3
Window
290d Wall 2 (Right -290)
- -
1
8.0
0.26
0.23
Insect Screen (default)
2
Window
110d Wall 3 (Left -110)
- -
1
80.0
0.29
0.19
Insect Screen (default)
22
Window
110d Wall 3 (Left -110)
- -
1
80.0
0.29
0.19
Insect Screen (default)
1.1
Window
20d Wall 4 (Front -20)
- -
1
120.0
0.26
0.23
Insect Screen (default)
AA
Window
20d Wail 4 (Front -20)
10.5 1.5
1.003
15.8
0.26
0.23
Insect Screen (default)
Q
Window
110d Wall 4 (Left -110)
- -
1
64.0
0.26
0.23
Insect Screen (default)
P
Window
110d Wall 4 (Left -110)
- --
1
18.0
1 0.26
0.23
Insect Screen (default)
P 2
Window
110d Wall 4 (Left -110)
- -
1
18.0
0.26
0.23
Insect Screen (default)
N
Window
110d Wall 4 (Left -110)
- -
1
10.0
0.26
0.23
Insect Screen (default)
N 2
Window
110d Wall 4 (Left -110)
- -
1
10.0
0.26
0.23
Insect Screen (default)
M
Window
110d Wali 4 (Left -110)
-- -
1
14.0
0.26
0.23
Insect Screen (default)
M 2
Window
110d Wall 4 (Left -110)
-- -
1
14.0
0.26
0.23
Insect Screen (default)
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEI HOD
Project ame: Jackson Ca culation Date/Time: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Feddedy-16.xml
C*RF-01 _
Page 7 of 13
K 2
Window
200d Wall 3 (Back -200)
-
-
1
110.0
0.26
0.23
Insect Screen (default)
7
Window
200d Wall 3 (Back -200)
20.5
10.0
1
205.0
0.29
0.19
Insect Screen (default)
BB
Window
200d Wall 3 (Back -200)
8.3
1.5
1.004
12.5
0.26
0.23
Insect Screen (default)
BB 2
Window
200d Wall 3 (Back -200)
8.3
1.5
1.004
12.5
0.26
0.23
Insect Screen (default)
CC
Window
200d Wall 3 (Back -200)
7.2
1.5
1
10.8
0.26
0.23
Insect Screen (default)
8
Window
245d Wall (- specify -270)
10.0
10.0
1
100.0
0.29
0.19
Insect Screen (default)
E 2
Window
290d Wall 4 (Right -290)
7.0
8.0
1
56.0
0.26
0.23
Insect Screen (default)
A
Window
335d Wall (- specify -335)
4.0
6.0
1.042
25.0
0.26
0.23
Insect Screen (default)
1
Window
335d Wall (- specify -335)
4.0
6.0
1.667
40.0
0.29
0.19
Insect Screen (default)
23
Window
290d Wall 5 (Right -290)
-
-
1
80.0
0.29
0.19
Insect Screen (default)
C 4
Window
290d Wall 5 (Right -290)
-
-
1
8.0
0.26
0.23
Insect Screen (default)
OVERHANGS AND FINS
01
02
03 .,
04
05 06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth , Dist Up
Left
Extent
Right t
EztentFIapHt2D th
Top Up
Ds't
Bot Up
Depth
Top Up Dist R
Bot Up
AA
2
W0.1
-"W i f -f 4 A 0 `2 L% --*0V V
d 0 0U 0
U'0 D
0
0
0
0
0
7
23
X0,1
23 F=
R235 F3
0 V
I 0
E OR
0
0
0
0
0
BB
2
0.1
2
2 0
0
0
0
0
0
0
0
0
13132
2
0.1
2
2 0
0
0
0
0
0
0
0
0
CC
2
0.1
2
2 0
0
0
0
0
0
0
0
0
8
18
0.1
18
18 0
0
0
0
0
0
0
0
0
E2
8
0.1
8
8 0
0
0
0
0
0
0
0
0
A
0
0
0
0 0
0
0
0
0
0
0
0
0
1
0
0
0
0 0
0
0
0
0
0
0
0
0
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Jackson Calculation Daterrime: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Fedderly-16.xml
CRF -01
Page 8 of 13
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
02
03
04
05
Total Cavity
Winter Design
Name
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Master Zone
992
93
None
0.8
No
• Cavity/ Frame: no insul. / 2x4 Top Chrd
Bedroom 2 & 3 Zone
794
109
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Living Zone
2217
171
None
0.8
No
• Inside Finish: Gypsum Board
Bedroom 4 Zone
Ceilings (below
68
None
0.8
No
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 + R21 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
-
Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Under Roof Joists: R-8.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
Ceiling
2z4 TopeChordiof;Roof Truss'@:24.
in. O.0
1
R
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof Shingle)
Attic RoofBedroom 2 8 3 Zone
Attic Roofs
Wood Framed
21[
X0:047
(Asphalt
4�
Cavity/ Frame: no insul. / 2x4 Top Chrd
AWood
2x4 Top Ehord of -Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofl-ounge Zone
Attic Roofs.
Framed,Ceiligg-:
P 4C. in. 1971C. R
w one" g
m 0:644
Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofLiving Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-8.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofBedroom 4 Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 21
0.047
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Covered Slab
Master Zone
992
93
None
0.8
No
Covered Slab 2
Bedroom 2 & 3 Zone
794
109
None
0.8
No
Covered Slab 3
Lounge Zone
397
68
None
0.8
No
Covered Slab 4
Living Zone
2217
171
None
0.8
No
Covered Slab 5
Bedroom 4 Zone
397
68
None
0.8
No
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTIIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD
Project ame: Jackson Ca culation Date/Time: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis Input File Name: Jackson-Feddedy-16.xml
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required —
C*RF-01
Page 9 of 13
WATER HEATING SYSTEMS
01
01
02 03 04 05. 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/2
DHW Pipe Insulation, All Lines DHW Heater 1 2 .0%
WATER HEATERS
01
02
03 04
05
06
07
08
Name
Heater Element Type -
Tank Volume
Tank Type' (gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural GasSmall
Storage� � �50 �
� �0 0.66 �
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION'',, ' ' " e� 0
01
02
0
it 0 °0.41 I Q
E 05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1-1/2
—
—
—
—
—
—
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cooling Component 1:1-leating Component 1:Air
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Distribution System 1:HVAC Fan 1:1
System
Cooling Component 2:Heating Component 2:Air
Other Heating and Cooling.
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Distribution System 2:HVAC Fan 2:1
System
Cooling Component 3:Heating Component 3:Air
Other Heating and Cooling
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
Distribution System 3:HVAC Fan 3:1
System
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Jackson Calculation Daterrime: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis Input File Name: Jackson-Fedderly-16.xml
CFORF-01
Page 10 of 13
HVAC - HEATING UNIT TYPES
01
02
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
06
Name
Efficiency
A _.V f' W X
Airflow Target
Multi -speed
Verified SEER
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 2
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
2 -hers -cool
Cooling Component 3
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
3
Am
I *am
**ww
X
-hers -cool
AV #011111k Is At 2L___ x "m a IL. -31 UP&
HVAC COOLING -HERS VERIFICATION
01
01
U2 t t"'
Ph, .t-" 03 a 01% 'e
% A 4 ��'•. nE"' ie"
OS
06
Name
t 1
Verified Airflow
A _.V f' W X
Airflow Target
V i '!t* l^° it
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
Cooling Component 2 -hers -cool
- Required
350
Required
Required
Required
Cooling Component 3 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1 -hers -dist
Air Distribution System 2
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
2 -hers -dist
Air Distribution System 3
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
3 -hers -dist
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-23 21:09:24
CERTI0 N
E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD
Project Name: Jackson Calculation Date/Time: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Feddedy-16.xml
C*RF-01
Page 11 of 13
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handier
Air Distribution System 1 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
Air Distribution System 3 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
HVAC -FAN SYSTEMS
01
02
03
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
04
01
06
'U62 0 k�,,
IAQ CFM
03
NameVerified
IAQ Recovery
Effectiveness(%)
Fan Watt Draw11
K Ilki
Required Fan Efficiency (Watts/CFM)
0.25
Default
0
Required
1
HVAC Fan 1 -hers -fan.
t ,, �„
Required„% % .0
#—*. r— ar"s
0.58
HVAC Fan 2 -hers -fan
'� f 9+ tom, �'
Required"" V 1
V_. ti
0.58
HVAC Fan 3 -hers -fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
92.73
0.25
Default
0
Required
COOLING VENTILATION
01
02
03
04
05
Name
Cooling Vent CFM
Cooling Vent Watts/CFM
Total Watts
Number of Fans
WH Fan 1
61
0.52459
32
1
WH Fan 2
61
0.52459
32
1
WH Fan 3
61
0.52459
32
1
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016 -OS -23 21:09:24
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IkOD
Project Name: Jackson Ca culation Date/Time: 21:07, Mon, May 23, 2016
Calculation'Description: Title 24 Analysis Input File Name: Jackson-Feddedy-16.xml
Registration Number: 216-NQ089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
CF*RF-01 _
Page 12 of 13
HERS Provider: CaICERTS inc.
Report Generated at: 2016-05-23 21:09:24
CERTI'VE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project
'VE
Jackson Ca culation DatefTime: 21:07, Mon, May 23, 2016
Calculation Description: Title 24 Analysis
Input File Name: Jackson-Feddedy-16.xm1
CF*RF-01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2016-05-23 21:16:32
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. .". — ,-„„ _ _ J; ` ``, - *—
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plansarid specifications submittedao-the enforcement agency for approvalwiththis,building permit application.
Responsible Designer Name:, -'.
LalLtl''
Oft
Responsible Designer Signature:Tim I
Scott f
Company: S p
r
Date Signed: q �pj
`4_,..� i t i 0 k
Scott Design and Title 24, Inc.
2016-05-23 21:16:32
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-N0089085C-000000000-0000 Registration Date/Time: 2016-05-23 21:16:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-23 21:09:24
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Jackson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/23/2016
Project Address
55350 Cherry Hills, PGA West La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,773
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft)
Special Features Status
Roof Wood Framed Attic
R 38 3,192
New
Roof Wood Framed Attic
R38 1,562
Rigid=R-21.0
New
Wall Wood Framed
R 21 4,768
New
Slab Unheated Slab -on -Grade
- no insulation 4,797
Perim = 509'
New
Demising Wood Framed
- no insulation 1,788
New
FENESTRATION
Orientation Area(ft)
I Total Area: 1,568 Glazin Percentage: 32.9
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor: 0.27
Exterior Shades Status
Rear (S) 291.0
0.260
0.23 none
none
Bug Screen New
Rear (S) 45.6
0.290
0.19 none
none
Bug Screen New
Right (Vtq 126.0
0.260
0.23 none
none
Bug Screen New
Front (N) 240.0
0.260
0.23 none
none
Bug Screen New
Left (E) 160.0
0.290
0.19 none
none
Bug Screen New
Front (N) 15.8
0.260
0.23 2.0
none
Bug Screen New
Left (E) 148.0
0.260
0.23 none
none
Bug Screen New
Rear (S) 205.0
0.290
0.19 23.0
none
Bug Screen New
Rear (S) 35.8
0.260
0.23 2.0
none
Bug Screen New
Right (W) 100.0
0.290
0.19 18.0
none
Bug Screen New
Right (Vtq 56.0
0.260
0.23 8.0
none
Bug Screen New
Right (NVIg 25.0
0.260
0.23 none
none
Bug Screen New
Right (NVtq 40.0
0.290
0.19 none
none
Bug Screen New
Right (V1q 80.0
0.290
0.19 none
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Fumace
80% AFUE
Split Air Conditioner
16.0 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner
16.0 SEER
Setback
New
2 Central Fumace
80% AFUE
Split Air Conditioner
16.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R -Value Status
HVAC 1 Ducted
Ducted Attic
8.0
New
HVAC 2 Ducted
Ducted Attic
8.0
New
HVAC 3 & 4 Ducted
Ducted Attic
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff
Distribution Status
2 Small Storage Gas
50
0.66
All Pipes Ins
New
EnemyPro6.7 by EnemySoft User Number., 6712
Run Code: 2016-05-23721:10:04
ID:
Pae 16 of 41
4
2013 ,Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures fisted, regardless of the
com fiance
approach used. Exceptions may apply, Review the respective code section or more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §I 10.8(1) when the
installation of a cool roof is specified on the CF] R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
§150.0(1):
Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c).
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
§150.06)IA:
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)IB:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
§150.00)2B:
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
,2013 -Low -Rise Residential Mandatory Measures Summary
4
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.06)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§I50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ I50.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
§150.0(o)IA:
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
'2013 ,Low -Rise Residential Mandatory Measures Summary
4
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 1 A(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9: 1
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ I50.0(k)I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)1C:
§130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§I50.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to $110.9, and complies with all other applicable requirements in §150.0(k)2.
§I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
§ I50.0(k)7:
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in '110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
,2013 tow -Rise Residential Mandatory Measures Summary
4
4
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, $140.7 and $141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, $130.0, §130.2, § 130.4, $140.7 and $141.0.
§150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 13 0.0 c .
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10 e .
§I 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§I 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
0
1
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ackson Residence
Date
5/23/2016
System Name
HVAC 1
Floor Area
992
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 554
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 149
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
11,763
1,054 295
11,837
Total Output Btuh 71,000
0
Output Btuh/s ft 71.6
679
582
Cooling System
01
0
Output per System 49,000
5,638
2,932 149
7,230
Total Output Btuh 49,000
1,489
3,986
-1,489
Total Output Tons 4.1
679
582
Total Output Btuh/s ft 49.4
Total Output s ftfTon 242.9
1 20,248
18,742
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24APA748/58PH"090 42,437 543
71,000
Airflow cfm/s ft
1.61
Airflow cfm/Ton
391.8
Outside Air %
9.3%
Total Adjusted System Output 42,437 543 71,000
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.15
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 67 OF
Outside Air
149 cfm Supply Fan
1,600 cfm
72 OF
68 OF 110 OF
Heating Coil 110 OF
ROOM t
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/64°F 81/64°F 56/54°F
Outside Air
149 cfm Supply Fan Cooling Coil 56 / 54 OF
1,600 cfm� ,:.
45.8% I'ROOM
76/62°F 76/62°F
EnergyPfo 6.7 by EnergySoff User Number. 6712 RunCode: 2016-05-23721:10:04 ID: Page 21 of 41
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ackson Residence
Date
5/23/2016
System Name
HVAC 2
Floor Area
1,167
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 784
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 175
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 89,000
15,378
1,240 428
17,477
Total Output Btuh 89,000
0
Output Btuh/s ft 76.3
888
859
Cooling System
0
0
Output perS sM58,000
6,629
3,015 175
8,494
Total Output B58,000
2,943
4,256
-2,943
Total Out ut T 4.8
8000011859
Total Output B49.7
Total Out ut s 241.4
1 26,726
24,746
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24APA760/58PH"110 50,595 911
89,000
Airflow cfm/s ft 1.71
Airflow cfm/Ton
413.8
89,000
Jan 1 AM
Outside Air % 8.8%
Total Adjusted System Output 50,595 911
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
Outside Air cfm/s ft 0.15
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 OF
0
Outside Air
175 cfm Supply Fan
2,000 cfm
72 OF
69 OF 111 OF
�1'
Heating Coil 110 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/64°F 81/65°F 57/56°F
&Outside Air —► �— —�
175 cfm Supply Fan Cooling Coil 58 / 56 OF
2,000 cfm
48.4% ROOM
76/63°F 76/63°F
EnergyPro 6.7 by EnergySoff User Number: 6712 Run Code: 2016-05-23721:10:04 ID: Page 22 of 41
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ackson Residence
Date
5/23/2016
System Name
HVAC 3 & 4
Floor Area
2,614
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,751
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 392
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
34,279
2,778 886
33,972
Total Output Btuh 142,000
0
Output Btuh/s ft 54.3
1,979
1,670
Cooling System
0
0
Output perSystem 49,000
14,780
6,768 392
18,990
Total Output Btuh 98,000
2978
9,5461
-2,978
Total Output Tons 8.2
1,9791
1,670
Total Output Btuhls ft 37.5
Total Output s ft/Ton 320.1
55,9941
53,323
Air System
CFM perSstem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
3,200
Carrier 24APA748/58PH"090 84,370 3,293
142,000
Airflow cfm/s ft
1.22
Airflow cfm/Ton
391.8
Outside Air %
12.3%
Total Adjusted System Output 84,370 3,293
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
142,000
Outside Air cfm/s ft 0.15
Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 66 OF
Outside Air
392 cfm Supply Fan
3,200 cfm
72 OF
67 OF 109 OF
Heating Coil 108 OF
ROOM
72 OF
U171�
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81/65°F 82/65°F 57/56°F
Outside Air
392 cfm Supply Fan Cooling Coil 58 / 56 OF
3,200 cfm
48.4% ROOM
77/63°F 76/63°F
EnergyPro 6.7 by EnergySoR User Number: 6712 Run Code: 2016-05-23721:10:04 ID: Page 23 of 41
0 0 0
ZONE •AD SUMMARY
ProjectDate
'Jackson Residence
• .
Name
HVAC 1
FloorSystem
..
ZONE LOAD SUMMARY
COOLING PEAK
A
MasterZone—
.LOAD)
ZONE LOAD SUMMARY
Project Name
Jackson Residence
Date
5/23/2016
System Name
HVAC 2
Floor Area
1,167
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK
HEATING PEAK
ZONE NAME SYSTEM NAME
Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM
Sensible
Latent
CFM 'Sensible
Bedroom 2 & 3 Zone
1.0 119 Aug 3 PM 467
13,721
2,719
272 16,937
Lounge Zone
1.0 56 Aug 3 PM 317
8,364
1,277
156 9,110
TOTALS 0 0 0 175 Aug 3 PM
22,085
3,996
26,046
BLOCK LOAD
EnergyPro 6.7 by EnergySoR User Number: 6712
Run Code: 2016-05-23721:10:04 ID:
Page 25 of 41
ZONE LOAD SUMMARY
Project Name
Jackson Residence
Date
5/23/2016
System Name
HVAC 3&4
Floor Area
2,614
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK
HEATING PEAK
ZONE NAME SYSTEM NAME
Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM
Sensible
Latent
CFM Sensible
Living Zone
1.0 333 Aug 3 PM 1,493
41,967
7,592
719 43,827
Bedroom 4 Zone
1.0 60 Aug 3 PM 258
7,334
1,359
168 9,339
TOTALS 0 0 0 392 Aug 3 PM
49,301
8,951
53,167
(BLOCK LOAD
EnergyPro 6.7 by EnergySoft User Number: 6712
Run Code: 2016-05-23721:10:04 /D:
Page 26 of 41
r1
L - -A
C J
•
ROOM HEATING PEAK LOADS
Project Name
Jackson Residence
Date
5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Floor Area 992.0 ftZ
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
AT °F
Btu/hr
c 720
= 287
= 2,550
= 2,930
= 288
= 3,123
= 0
c
=
=
=
=
=
—
=
=
9,898
46 = 1,939
R-38 Roof Attic
602.0
X
X
0.0260
X
X
46
R-38 + R21 Roof Attic
371.0
0.0168
46
R-21 Wall (W.21.2x6.16)
803.4
X
0.0690
X
X
X
X
X
X
X
X
46
Dual Tinted .26/.23
245.0
X
X
X
X
X
X
X
X
X
X
X
X
0.2606
46
Dual Tinted .29/.19
21.6
0.2900
46
Slab -On -Grade
perim = 93.0
0.7300
46
'R-0 Interior Wall
714.0
0.3560
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page Total
/60]' X
AT
X
to another room
9.00 X 0.266
Ceiling Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 992 X
Area
TOTAL HOURLY HEAT LOSS FOR ROOM 11,837
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-05-23721:10:04 ID: Page 30 of 41
•
ROOM HEATING PEAK LOADS
Project Name
Jackson Residence
Date
5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2 & 3
Floor Area 794.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 of
Conduction
Area U -Value
794.0 X 0.0168
907.0 X 0.0690
174.0 X 0.2600
24.0 X 0.2900
perim = 109.0 X 0.7300
310.0 X 0.3560
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to another room
X 794 X 9.00 X 0.266
Area Ceiling Height ACH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
c
=
_
=
=
=
=
=
=
=
46
Btu/hr
R-38 + R21 Roof Attic
46
614
R-21 Wall (W.21.2x6.16)
46
2,879
Dual Tinted. 261.23
46
2,081
Dual Tinted .29/.19
46
320
Slab -On -Grade
46
3,660
'R-0 Interior Wall
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
Page Total
/60] X
AT
9,554
= 1,552
TOTAL HOURLY HEAT LOSS FOR ROOM 11,106
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-05-23721:10:04 /D: Page 31 of 41
•
•
•
ROOM HEATING PEAK LOADS
Project Name
Jackson Residence
Date
5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Lounge
Floor Area 373.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 6F
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
Btu/hr
= 1446
c 778
= 2,134
= 2,283
= 0
-
=
=
=
=
=
=
=
=
=
_
_
_
5,642
46 = 729
R-38 Roof Attic
373.0
0.0260
46
R-21 Wall (W.21.2x6.16)
245.0
0.0690
46
Dual Tinted .29/.19
160.0
0.2900
46
Slab -On -Grade
perm = 68.0
0.7300
46
-R-21 Wall (W.21.2x6.16)
650.0
0.0690
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 373 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/60] X
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 6,371
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016.05-23721:10:04 /D: Page 32 of 11
Now
1�
ROOM HEATING PEAK LOADS
Project Name
Jackson Residence
Date
5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living
Floor Area 2,217.0 f'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
AT °F Btu/hr
X 46 = 2,652
X 46 = 4,112
X 46 = 6,107
X 46 _ 4,602
X 46 = 5,742
X 0 = 0
X =
X =
X =
X =
X
X =
X
X
X =
X =
X
X
X
X =
X _
X
X =
X =
X
X _
X =
X =
X =
X -
X
Page Total 23,214
/ 60 ] X 46 = 4,333
AT
R-38 Roof Attic
2,2170
0.0260
R-21 Wall (W.21.2x6.16)
1,295.4
0.0690
Dual Tinted .26/.23
510.6
0.2600
Dual Tinted. 29/.19
345.0
0.2900
Slab -On -Grade
peri. 171.0
0.7300
"R-0 Interior Wall
764.0
0.3560
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 2,217 X
Area
another room
9.00 X 0.266
Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 27,547
EnergyPro6.7 by EnergySoR. User Number: 6712 Run Code: 2016-05-23721:10:04 ID: Page 33 of 41
C
C
ROOM HEATING PEAK LOADS
Project Name
Jackson Residence
Date
5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 4
Floor Area 397.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value AT °F
X 0.0168 X 46 =
X 0.0690 X 46 =
X 0.2900 X 46 =
X 0.2600 X 46 =
X 0.7300 X 46 =
X 0.0690 X 0 =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X
X X
X X =
X X =
X X =
X X
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X c
to another room Page Total
9.00 X 0.266 /60] X 46
Ceiling Height ACH AT
Btu/hr
R-38 + R21 Roof Attic
397.0
307
R-21 Wall (W.21.2x6.16)
597.0
1,895
Dual Tinted .29/.19
80.0
1,067
Dual Tinted .26/.23
8.0
96
Slab -On -Grade
perim = 68.0
2,283
-R-21 Wall (W.21.2x6.16)
270.0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 397 X
Area
5,648
= 776
TOTAL HOURLY HEAT LOSS FOR ROOM 6,424
EnergyPro 6.7 by EnergySott User Number: 6712 Run Code: 2016-05-23721:10:04 /D: Page 34 of 41
r�
U
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jackson Residence
1 5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area
992.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range*
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
602.0 X 0.0260
X
56.0 =
877
R-38 + R21 Roof Attic
W 371.0 X 0.0168
X
56.0 =
349
R-21 Wall (W.21.2x6.16)
(N) 70.0 X 0.0690
X
25.7 =
124
R-21 Wall (W.21.2x6.16)
(E) 180.0 X 0.0690
X
32.1 =
399
R-21 Wall (W.21.2x6.16)
(S) 159.4 X 0.0690
X
28.2 =
310
R-21 Wall (W.21.2x6.16)
(lm 394.0 X 0.0690
X
31.8 =
864
"R-0 Interior Wall
714.0 X 0.3560
X
0.0 =
0
X
X
=
X
X I=
Page Total
2.923
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
K
(S) 0.0 X 13.7 +
121.0 X
16.1 =
1,950
L
(S) 0.0 X 13.7 +
16.0 X
16.1 =
258
L
(S) 0.0 X 13.7 +
18.0 x
16.1 =
290
6
(S) 0.0 X 12.9 +
21.6 X
14.8 =
320
J
I'm 0.0 X 13.7 +
21.0 X
24.6 =
517
J
W 0.0 X 13.7 +
21.0 X
24.6 =
517
H
W 0.0 X 13.7 +
12.0 X
24.6 =
295
G
W 0.0 X 13.7 +
36.0 X
24.6 =
886
X +1
X
=
Page Total
5,033
Internal Gain
Btulhr
Occupants
3.0 Occupants X 245
Btuh/occ.
=
729
Equipment
992 Floor Area X 0.50
w/sgft
=
1,693
Infiltration: 1.064
X 0.88 X 40.92 X 36 =
1,385
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
11,763
Latent Gain
Btu/hr
Occupants
3 0 Occupants X 155
Btuh/occ.
=
461
Infiltration: 4,771
X 0.88 X 40.92 x 0.00344 =
593
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
461
EneMyPro 6.7 bV EnerqVSoft
User Number., 6712 RunCode: 2016-05-23721:10:04 ID:
Page 35 of 41
11
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Jackson Residence
ROOM INFORMATION DESIGN CONDITIONS
Date
5/23/2016
Room Name
Bedroom 2 & 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
794.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
76 OF
Outdoor Daily Ranqe:
34 OF
Opaaue Surfaces
R-38 + R21 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W..21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
-R-0 Interior Wall
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
794.0
0.0168
56.0
240.0
0.0690
25.7
200.0
0.0690
32.1
145.0
0.0690
28.2
322.0
0.0690
31.8
310.0
0.3560
0.0
0.0
13.7
20.0
16.1
0.0
13.7
6.0
16.1
0.0
12.9
24.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FanPstratinn
E
c
D
C
B
B
3
F
F
Orientation
Shaded Unshaded
Btu/hr
1 2,6041
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
0.0
13.7
56.0
17.0
0.0
13.7
8.0
17.0
0.0
13.7
48.0
17.0
0.0
13.7
8.0
17.0
0.0
13.7
20.0
16.1
0.0
13.7
6.0
16.1
0.0
12.9
24.0
14.8
0.0
13.7
1 10.0
24.6
0.0
13.7
10.0
1 24.6
Page Total
Btulhr
953
136
817
136
322
97
356
246
246
3, 310
Internal Gain Btu/hr
Occupants 2.4 Occupants X 245 Btuh/occ. 584
Equipment 794 Floor Area X 0.50 w/sgft = 1,355
Infiltration: 1.064 X 0.88 X 32.75 X 36 = 1,109
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,1581
Latent Gain Btu/hr
Occupants 2.4 Occupants X 155 Btuh/occ. = 369
Infiltration: _ 4.771 X 0.88 X 32.75 X 0.00344 = 475
Air Sensible CFM ELA AW
i, TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Number: 6712
•
L✓J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jackson Residence
1 5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 2 & 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
794.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X I J
X
=
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
C
0.0 X 13.7 +
8.0
X 24.6 c
197
X +
X =
X +
X —
X +
X =
X +
X =
X +.
X =
X +
X =
X +
X =
X +1
XI
Page Total
19
Internal Gain
Btu/hr
Occupants
2 4 Occupants X 245
Btuh/occ.
=
584
Equipment
794 Floor Area X 0.50
w/sgft
=
1,355
Infiltration: 1.064
X 0.88 X 32.75 X 36 =
1,109
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
9,158
Latent Gain
Btu/hr
Occupants
2 4 Occupants X 155
Btuh/occ.
=
369
Infiltration: 4,771
X 0.88 X 32.75 X 0.00344 =
475
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
369
EnemyPro 6.7 by EnemySoft
User Number: 6712 RunCode: 2016-05-23721:10:04 ID:
Page 37 of 41
•
•
C]
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jackson Residence
5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Lounge
Outdoor Dry Bulb Temperature
112 OF
Floor Area
373.0 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
(W) 373.0 X 0.0260
X
56.0 =
543
R-21 Wall (W.21.2x6.16)
(N) 50.0 X 0.0690
X
25.7 =
89
R-21 Wall (W.21.2x6.16)
(E) 105.0 X 0.0690
X
32.1 =
233
R-21 Wall (W.21.2x6.16)
(W) 90.0 X 0.0690
X
31.8 =
197
-R-21 Wall (W.21.2x6.16)
650.0 X 0.0690
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1,062
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded,
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
2
(E) 0.0 X 12.9 +
80.0
X 23.3 =
1,864
2
(E) 0.0 X 12.9 +
80.0
X 23.3 =
1,864
X +
X =
X +
X =
X +
X =
X +
X =
X +
X -
X +
X _
X +
X =
Page Total
3,72
Internal Gain
Btu/hr
Occupants
1.1 Occupants X 245
Btuh/occ.
=
274
Equipment
373 Floor Area X 0.50
w/sq ft
=
637
Infiltration: 1.064
X 0.88 X 15.38 X 36 =
521
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
6,220
Latent Gain
Btu/hr
Occupants
11 Occupants X 155
Btuh/occ.
=
173
Infiltration: 4,771
X 0.88 X 15.38 X 0.00344 =
223
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
173
EnemyPro 6.7 by EnemySoft
User Number: 6712 Run Code: 201605-23721:10:04 ID:
Page 38 of 41
I1
u
.
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Jackson Residence
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temper
Opaque Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
"R-0 Interior Wall
Orientation
DESIGN CONDITIONS
Living Outdoor Dry Bulb Temperature
2,217.0 ft2 Outdoor Wet Bulb Temperature
76 OF Outdoor Daily Range:
Date
5/23/2016
112 °F
78 OF
34 OF
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
2,217.0
0.0260
56.0
212.2
0.0690
25.7
584.0
0.0690
32.1
294.2
0.0690
28.2
92.0
0.0690
33.0
52.0
0.0690
31.8
61.0
0.0690
29.0
764.0
0.3560
0.0
10.0
26.4
0.0
13.7
10.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fanantratinn
1.1
AA
Q
P
P
N
N
M
M
Internal Gain
Orientation
(N)
(N)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
13.7
120.0
17.0
0.0
13.7
15.8
17.0
0.0
13.7
64.0
26.4
0.0
13.7
18.0
26.4
0.0
13.7
18.0
26.4
0.0
13.7
10.0
26.4
0.0
13.7
10.0
26.4
0.0
13.7
14.0
26.4
0.0
13.7
14.0
26.4
Page Total
6.7 Occupants X 245 Btuh/occ.
2,217 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.88 X 91.44 X 36 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
6.7 Occupants X 77_155 Btuh/occ.
Infiltration: 4,771 X 0.88 X 91.44 X 0.00344 =
Air Sensible CFM ELA OW
Btu/hr
1
1
1
Btu/hr
2,043
269
1,688
475
475
264
264
369
6,;
Btu/hr
1,1
3,!
Btu/hr
1.031
1 1,3251
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,0311
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Jackson Residence
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temaer
Opaque Surfaces Orientation
5/23/2016
DESIGN CONDITIONS
Living Outdoor Dry Bulb Temperature
2,217.0 ft' Outdoor Wet Bulb Temperature
76 OF Outdoor Daily Range:
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
=
0.01
13.7
110.0
16.1
205.0
12.9
0.0
14.8
12.5
13.7
0.0
16.1
12.5
13.7
0.0
16.1
10.8
13.7
0.0
16.1
100.0
12.9
0.0
24.1
24.2
13.7
31.8
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPnP_Rtrntinn
K
7
BB
BB
CC
8
E
A
1
Internal Gain
Orientation
(S)
(S)
(S)
(S)
(S)
(tM
(►M
(NIA
(NIA9
Shaded Unshaded
Area
x
x
x
x
x
x
x
x
x
GLF
+
+
+
+
+
+
+
+
+
Area
x
x
x
x
x
x
x
x
x
GLF
=
=
=
=
=
=
=
=
=
0.01
13.7
110.0
16.1
205.0
12.9
0.0
14.8
12.5
13.7
0.0
16.1
12.5
13.7
0.0
16.1
10.8
13.7
0.0
16.1
100.0
12.9
0.0
24.1
24.2
13.7
31.8
24.6
0.0
13.7
25.0
21.1
0.01
1 12.9
40.0
19.0
Page Total
112 OF
78 OF
34 OF
Btu/hr
Btu/hr
1,773
2,634
172
172
148
1,285
1,115
528
758
8,5861
6.7 Occupants x 245 Btuh/occ. 1
2,217 Floor Area x 0.50 W/sgft = 3,
Infiltration: 1.064 x 0.88 x 91.44 x 36 =
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,2261
Latent Gain Btu/hr
Occupants 6 7 Occupants x 155 Btuh/occ. = ,
Infiltration: 4,771 x 0.88 x 91.44 x 0.00344 = 3
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,0311
I EnemyPro 6.7 by EnemySoft User Number: 6712 Run Code: 2016-05-23721:10:04 ID: Page 40 of 411
4.
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jackson Residence
1 5/23/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
397.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF I
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 + R21 Roof Affic
(IA/) 397.0 X 0.0168
X
56.0 =
374
R-21 Wall (W.21.2x6.16)
(N) 210.0 X 0.0690
X
25.7 =
372
R-21 Wall (W.21.2x6.16)
(E) 160.0 X 0.0690
X
32.1 =
355
R-21 Wall (W.21.2x6.16)
(S) 50.0 X 0.0690
X
28.2 =
97
R-21 Wall (W.21.2x6.16)
(149 177.0 X 0.0690
X
31.8 =
388
-R-21 Wall (W.21.2x6.16)
270.0 X 0.0690
X
0.0 . =
0
X
X
=
X
X
=
X
X
=
Page Total
1,586
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
2
(119 0.0 X 12.9 +
80.0
X 21.8 =
1,747
C
0.0X 13.7+
8.0X
24.6=
197
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
• X +1
X =
Page Total
1.944
Internal Gain
Btu/hr
Occupants
1.2 Occupants X 245
Btuh/occ.
=
292
Equipment
397 Floor Area X 0.50
w/sgft
=
677
Infiltration: 1.064
X 0.88 X 16.37 X 36 =
554
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
5,053
Latent Gain
Btu/hr
Occupants
12 Occupants X 1 155
Btuh/occ.
=
185
Infiltration: 4,771
X 0.88 X 16.37 X 0.00344 =
237
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
185
EnemyPro 6.7 by EnemySoft
User Number: 6712 RunCode: 2016-05-23721:10:04 ID:
Page 41 of 41
MINIMUM —
2 X B STUDS
It
3.750
1 -
SURFACE
VIEW
INSTALLATION TYPES
SUB -FLOOR 5/8• DRYWALL CAP
MINIMUM
OPENING
FIXTURE WHIP w/ CONNECTORS
CONNECTION MADE AT JUNCTION BOX
JUNCTION BOX ON TOP OR SIDE
— .500
HOLES HEATER FLUSH
w/ FINISHED CEILING
DECORATIVE TRIM
ALLY COVERING FLANGE
EXPOSED FLANGE
4'00
WARNINGS:
This frame is ONLY to be used on
a Flat non -sloped ceiling.
• Heater must face straight down.
• Frame and Heater cannot be Installed
on a pitched angle.
NOTES:
• Heater suspends (Gravity) by resting on
adjustable tabs in flush mount fixture.
• Mounting holes on Surface Flange to be
determined and drilled by Contractor/Installer.
• Supplied with Hi -Temp Fixture Whip
'
and Hi -Temp Wire Nuts.
• Coil excess flex into heater cavity.
• Use Licensed Electrician ONLY
EXPOSED FLANGE