Loading...
BRES2015-0341 Title 24r. BUILDING ENERGY ANALYSIS REPORT RECEIVE PROJECT: SEP 0 3 2015 Filler & Sandy Investments, LLC CITY OF LA QUINTA Lot 1 B, The Madison Club C®MMUNM DE'vELOPMEN La Quinta, CA 92253 LA Pro' Designer: Project es gner. PAR Development 42-240 Green Way, Suite C Palm Desert, CA 92211 (760) 341-5716 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77085 Michigan Drive Palm Desert, CA 92211 (760) 200-478[DATE ) ®F �� BUILDING S '47 pFj y DEPT. CR CONST UC� Z6 BY Job Number: Date: 8/31/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. EnemvPro 6.7 by EnemvSoft User Number: 6712 ID: r(00000' CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE a OD Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml CRF -01 Page 1 of 17 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Filler/Sandy Inv 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location Lot 1 B, The Madison clubl-a Quinta Compliance Margin Percent Improvement 04 City Indian Wells 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 9974 15 Number of Zones 5 16 Slab Area (ft) 8137 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft) N/A 21 Glazing Percentage (%) 47.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performan6T4 �c { " 'it it e� rr 02 This building incorporates features'tthat require field testing and/or verification by a certifed)HERS rater,underthe supervision of a CEC-approved HERS provider. 1 i...., i t_. i, 3 i r. _4 �. 03 This building incorporates one or�more Special Features shown below � . ^,* hf F ii tr:: f"a -.:.1► �-" � 'e...d` WP fir �,.,�' iG � Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.19 4.27 -1.08 -33.9% Space Cooling 84.76 77.21 7.55 8.9% IAQ Ventilation 0.98 0.98 0.00 0.0% Water Heating 2.57 8.92 -6.35 -247.1% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 91.50 91.38 0.12 0.1% Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Cathedral Ceiling • Window overhangs and/or fins HERS FEATURE SUMMARY C*RF-01 Page 2of17 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • Building Envelope Air Leakage • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified low -leakage ducts entirely in conditioned space Cn,,::4 Domestic Hot Water System Verifications: • —None— � RT", � ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 124.86 124.74 0.12 0.1% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Filler/Sandy Inv 9974 1 15 5 0 2 Registration Number: 215-N6307872A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-08-28 17:03:27 Report Version - CF1R-08252015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-08-28 16:52:00 CERTI'fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1B-PAR-Corner.xml C*RF-01 - Page 3 of 17 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Suite Conditioned HVAC 11 1459 10 DHW Sys 1 Living/Kit/Din/Office Conditioned HVAC 2, 3, 4 & 52 5046 10 DHW Sys 1 Guest 1 Conditioned HVAC 2, 3, 4 & 52 429 10 DHW Sys 1 Guest 2 Conditioned HVAC 2, 3, 4 & 52 742 10 DHW Sys 1 Casita Conditioned HVAC 6 & 73 2298 10 DHW Sys 3 C rt* RTS,, i Cp* d It 0 HERS �„ n i Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTl*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE C*OD Project Name: Filler/Sandy Inv Ca elation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml C -*RF -01 - Page 4 of 17 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ftz) Tilt (deg) 25d Wall Master Suite R-21 Wall (W.21.2x6.16) 25 - specify - 85 90 115d Wall Master Suite R-21 Wall (W.21.2x6.16) 0 Front 156 100.4 90 205d Wall Master Suite R-21 Wall (W.21.2x6.16) 205 - specify - 260 218.8 90 295d Wall Master Suite R-21 Wall (W.21.2x6.16) 295 - specify - 420 180 90 Roof 3 Master Suite R-38 Roof Attic 1443.9 N Wall Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 0 Front 813 551.5 90 25d Wall 2 Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 25 - specify - 156 109.69 90 50d Wall Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 50 - specify - 204.1 204 90 E Wall Living/KiUDin/Office R-21 Wall (W.21.2x6.16) 90 Left 580 105.2 90 115d Wall 2 Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 115 - specify - 612 311.501 90 S Wall Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 180 Back 130 11.4. 90 190d Wall Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 190 - specify - 105 90 205d Wall 2 Living/Kit/Din/Officef"^f R 21 Wall (W.21:2x616) (j-206 specify- 903 690.189 90 230d Wall Living/Kit/Din/Officei ,-.�� R241iWall (W 21:2x6:16) `230 �- 'specify 242 169 90 W Wall Living/Kit/Din/Office `� ` R=21�Wall{W21:2x&i16)3 z "Z276 U tRigFit V 280 181.5 90 295 Wall Living/Kit/Din/Office "' Ra21 Wall,(W.21:2z6.16)( 295 f specify- i 170 18 90 340d Wall Living/Kit/Din/Office R-21 Wall (W.21.2x6.16) 340 - specify - 105 27 90 Roof 4 Living/Kit/Din/Office R-38 Roof Attic 5021.4 230d Wall 2 Guest 1 R-21 Wall (W.21.2x6.16) 230 - specify - 65 40 90 295d Wall 2 Guest 1 R-21 Wall (W.21.2x6.16) 295 - specify - 95 90 90 320 Wall Guest 1 R-21 Wall (W.21.2x6.16) 320 - specify - 59 90 Roof 5 Guest 1 R-38 Roof Attic 429 25d Wall 3 Guest 2 R-21 Wall (W.21.2x6.16) 25 - specify - 220 120 90 115d Wall 3 Guest 2 R-21 Wall (W.21.2x6.16) 115 - specify - 345 58.5 90 205d Wall 3 Guest 2 R-21 Wall (W.21.2x6.16) 205 - specify - 50 90 230d Wall 3 Guest 2 R-21 Wall (W.21.2x6.16) 230 - specify - 155 18 90 295d Wall 3 Guest 2 R-21 Wall (W.21.2x6.16) 295 - specify - 205 104 90 320d Wall Guest 2 R-21 Wall (W.21.2x6.16) 320 - specify - 165 80 90 Roof 6 Guest 2 R-38 Roof Attic 742 10d Wall Casita R-21 Wall (W.21.2x6.16) 10 - specify - 220 89 90 Registration Number: 215•N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI'fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml CFORF-01 - Page 5 of 17 60d Wall Casita R-21 Wall (W.21.2x6.16) 60 - specify - 190 36 90 65d Wall Casita R-21 Wall (W.21.2x6.16) 65 - specify - 156 Zone 90 100d Wall Casita R-21 Wall (W.21.2x6.16) 100 - specify - 550 10 90 155d Wall Casita R-21 Wall (W.21.2x6.16) 155 - specify - 264 203.2 90 170d Wall Casita R-21 Wall (W.21.2x6.16) 170 - specify - 276 221 90 S Wall 2 Casita R-21 Wall (W.21.2x6.16) 180 Back 244 156.9 90 190d Wall 2 Casita R-21 Wall (W.21.2x6.16) 190 - specify - 70 12 90 240d Wall Casita R-21 Wall (W.21.2x6.16) 240 - specify - 150 30 90 W Wall 2 Casita R-21 Wall (W.21.2x6.16) 270 Right 436 210.053 90 280d Wall Casita R-21 Wall (W.21.2x6.16) 280 - specify - 310 111.6 90 330d Wall Casita R-21 Wall (W.21.24.16) 330 - specify - 530 266 90 Roof 7 Casita R-38 Roof Attic 2298 OPAQUE SURFACES - Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio. n N ._.__ A aft) ,r� Skylight -Area (ft2j_ Roof Rise (z in 12) Roof _Pitch1. Roof Tilt (deg) Roof Reflectance Roof Emittance Framing Factor Roof Master Suite \R-38 Roof Attic1 1 Right I; } 15t2'' 15.1-)) N 1121'1 1. ((0.17 9.46 0.65 0.88 0.1 Roof 2 Living/Kit/Din/Office I -N'RQg38 RoofAtticl :::' �, kig�f K 24.7 24:fi L 2-0 17y 9.46 0.65 0.88 0.1 v i a €._ a a. _.e r- & It 6_-.T is a a_0 Z_ I'% ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Suite Attic RoofMaster Suite Unventilated 2 0.65 0.88 No Yes Attic Living/Kit/Din/Office Attic RoofLiving/Kit/Din/Office Unventilated 2 0.65 0.88 No Yes Attic Guest 1 Attic RoofGuest 1 Unventilated 3 0.65 0.88 No Yes Attic Guest 2 Attic RoofGuest 2 Unventilated 3 0.65 0.88 No Yes Attic Casita Attic RoofCasita Unventilated 2 0.65 0.88 No Yes Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. ` CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTIIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1B-PAR-Corner.xml CIORF-01 - Page 6 of 17 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U -factor SHGC Exterior Shading H8 Window 115d Wall (Front -0) 3.8 8.0 1 30.4 0.29 0.19 Insect Screen (default) D10 Window 115d Wall (Front -0) 7.0 10.0 1 70.0 0.34 0.19 Insect Screen (default) H7 Window 205d Wall (- specify -205) 8.5 8.0 1 68.0 0.29 0.19 Insect Screen (default) D09 Window 205d Wall (- specify -205) 7.0 10.0 1 70.0 0.34 0.19 Insect Screen (default) H2 Window 205d Wall (- specify -205) 6.1 8.0 1 48.8 0.29 0.19 Insect Screen (default) H4 Window 205d Wall (- specify -205) 6.0 4.0 1 24.0 0.29 0.19 Insect Screen (default) G2 Window 205d Wall (- specify -205) 2.0 4.0 1 8.0 0.29 0.19 Insect Screen (default) 1-11 Window 295d Wall (- specify -295) 6.5 8.0 1 52.0 0.29 0.19 Insect Screen (default) H3 Window 295d Wall (- specify -295) 6.5 4.0 1 26.0 0.29 0.19 Insect Screen (default) G1 Window 295d Wall (- specify -295) - - 1 102.0 0.29 0.19 Insect Screen (default) Skylight Skylight Roof (Right -270) 1 4.0 0.15 0.10 Skylight 2 Skylight Roof;(Right-270)'") j5^-,_„3 r,= tr �zi f, 1 4.0 0.15 0.10 Skylight 3 Skylight Roof (Right 270)N Y 1�= N: f 11 yti I Z^7.1 0.15 0.10 C1 Window N 1Na�ll-(1 %„nt-0) j� �. �F ,i � 5 8 10.0 1 58 0 0.29 0.19 Insect Screen (default) A2 Window �*.�{� N Wall (Front?0) r p o 2co i c 10.0 r 2.5' 556.6 0.29 0.19 Insect Screen (default) D01 Window N Wall (Front -0) 6.0 10.0 1 -60.0 1.19 0.59 Insect Screen (default) A3 Window N Wall (Front -0) 10.5 1.7 10.028 179.0 0.29 0.19 Insect Screen (default) Al Window N Wall (Front -0) 2.3 10.0 1 23.0 0.29 0.19 Insect Screen (default) D29 Window N Wall (Front -0) 12.0 12.0 1 144.0 0.34 0.19 Insect Screen (default) S2 Window N Wall (Front -0) 12.0 1.7 1 20.4 0.29 0.19 Insect Screen (default) P1 Window N Wall (Front -0) - - 1 5.7 0.29 0.19 Insect Screen (default) P2 Window N Wall (Front -0) - - 1 5.7 0.29 0.19 Insect Screen (default) P12 Window N Wall (Front -0) - - 1 5.7 0.29 0.19 Insect Screen (default) L4 Window 25d Wall 2 (- specify -25) - - 1 4.0 0.29 0.19 Insect Screen (default) K4 Window 25d Wall 2 (- specify -25) 8.0 8.0 1 64.0 0.29 0.19 Insect Screen (default) K6 Window 25d Wall 2 (- specify -25) 8.0 4.6 0.978 36.0 0.29 0.19 Insect Screen (default) P11 Window 25d Wall 2 (- specify -25) - - 1 5.7 0.29 0.19 Insect Screen (default) C2 Window 50d Wall (- specify -50) - - 1 1 68.0 0.29 0.19 Insect Screen (default) C3 Window 50d Wall (- specify -50) - - 1 1 68.0 0.29 0.19 Insect Screen (default) Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE qPOD Project Name: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml CFORF-01 Page 7 of 17 C4 Window 50d Wall (- specify -50) - - 1 68.0 0.29 0.19 Insect Screen (default) N1 Window E Wall (Left -90) 5.0 5.5 1 27.5 0.29 0.19 Insect Screen (default) D19 Window E Wall (Left -90) 5.0 10.0 1 50.0 0.34 0.19 Insect Screen (default) M1 Window E Wall (Left -90) - - 1 22.0 0.29 0.19 Insect Screen (default) P10 Window E Wall (Left -90) - - 1 5.7 0.29 0.19 Insect Screen (default) L3 Window 115d Wall 2 (-specify -115) - - 1 60.0 0.29 0.19 Insect Screen (default) D17 Window 115d Wall 2 (- specify -115) 3.0 10.0 1 30.0 0.34 0.21 Insect Screen (default) K3 Window 115d Wall 2 (- specify -115) 6.3 8.0 1 50.4 0.29 0.19 Insect Screen (default) K5 Window 115d Wall 2 (- specify -115) 6.3 4.6 1.001 29.0 0.29 0.19 Insect Screen (default) D16 Window 115d Wall 2 (- specify -115) 9.3 10.0 1 93.0 0.34 0.19 Insect Screen (default) K2 Window 115d Wall 2 (- specify -115) 7.7 4.9 0.999 37.7 0.29 0.19 Insect Screen (default) P9 Window 115d Wall 2 (- specify -115) - - 1 5.7 0.29 0.19 Insect Screen (default) P8 Window 115d Wall 2 (- specify -115) -- - 1 5.7 0.29 0.19 Insect Screen (default) P6 Window S Wall (Back -180) - - 1 5.7 0.29 0.19 Insect Screen (default) P7 Window S Wall (Back -180) - - 1 5.7 0.29 0.19 Insect Screen (default) D15 Window 205d Wall 2-(�specify f 205) c16.5 ,74 10.0 r 1 165.0 0.34 0.19 Insect Screen (default) K1 Window 6205d Will 2 (- specify i 205) 1 11-,! 16.5 ti: ,-, 4.8 r 1)J `"'79.2 0.29 0.19 Insect Screen (default) Window Window 205d Wall,-2_(=,s6ecify'-,205)'- I U U 5.8 4?0 1 11.034 " [ 24.0 0.29 0.19 Insect Screen (default) D12 Window N265d Wall -2-(- s eci "205 22Y0 ` 10.0 1 '"'220.0 0.34 0.19 Insect Screen default J1 Window 205d Wall 2 (- specify -205) -- - 1 102.0 0.29 0.19 Insect Screen (default) 11 Window 205d Wall 2 (- specify -205) 10.0 10.0 1 100.0 0.34 0.19 Insect Screen (default) C6 Window 230d Wall (- specify -230) - - 1 68.0 0.29 0.19 Insect Screen (default) D05 Window 230d Wall (- specify -230) - - 1 33.0 0.34 0.21 Insect Screen (default) C5 Window 230d Wall (- specify -230) - - 1 68.0 0.29 0.19 Insect Screen (default) D28 Window W Wall (Right -270) 12.0 12.0 1 144.0 0.34 0.19 Insect Screen (default) S1 Window W Wall (Right -270) 12.0 1.7 1 20.4 0.29 0.19 Insect Screen (default) P3 Window W Wall (Right -270) - - 1 5.7 0.29 0.19 Insect Screen (default) P4 Window- W Wall (Right -270) - - 1 5.7 0.29 0.19 Insect Screen (default) P5 Window W Wall (Right -270) - - 1 5.7 0.29 0.19 Insect Screen (default) R1 Window 295 Wall (- specify -295) - - 1 18.0 0.29 0.19 Insect Screen (default) 131 Window 340d Wall (- specify -340) - - 1 13.5 0.29 0.19 Insect Screen (default) B2 Window 340d Wall (- specify -340) -- - 1 13.5 0.29 0.19 Insect Screen (default) Skylight 4 Skylight Roof.2 (Right -270) 1 4.0 0.15 0.10 Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD Project Name: Filler/Sandy Inv Calculation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml C*RF-01 - Page 8 of 17 Skylight 5 Skylight Roof 2 (Right -270) 1 4.0 0.15 0.10 Skylight 6 Skylight Roof 2 (Right -270) 1 12.6 0.15 '0.10 Skylight 7 Skylight Roof 2 (Right -270) 1 4.0 0.15 0.10 F1 Window 230d Wall 2 (- specify -230) 4.0 10.0 1 40.0 0.29 0.19 Insect Screen (default) D06 Window 295d Wall 2 (- specify -295) 9.0 10.0 1 90.0 0.34 0.21 1 Insect Screen (default) d02 Window 25d Wall 3 (- specify -25) 4.0 10.0 2 80.0 0.34 0.19 Insect Screen (default) E1 Window 25d Wall 3 (- specify -25) - - 1 40.0 0.29 0.19 Insect Screen (default) D1 Window 115d Wall 3 (- specify -115) - - 1 58.5 0.29 0.19 Insect Screen (default) D2 Window 230d Wall 3 (- specify -230) - - 1 18.0 0.29 0.19 Insect Screen (default) D03 Window 295d Wall 3 (- specify -295) 8.0 10.0 1 80.0 0.34 0.19 Insect Screen (default) E2 Window 295d Wall 3 (- specify -295) - - 1 8.0 0.29 0.19 Insect Screen (default) E2 2 Window 295d Wall 3 (- specify -295) - - 1 16.0 0.29 0.19 Insect Screen (default) D04 Window 320d Wall (- specify -320) 8.0 10.0 1 80.0 0.34 0.21 Insect Screen (default) U7 Window 10d Wall (- specify -10) 5.0 10.0 1 50.0 0.29 0.19 Insect Screen (default) U5 Window 1 O Wall (- specify -10) - - 1 27.0 0.29 0.19 Insect Screen (default) U2 Window 1 Od Wall -(=specify s10) r;=7 r "Nh c"4 4- - 1 12.0 0.29 0.19 Insect Screen (default) W4 Window 60d Wall (- spec-ifyOj( Ir` 2.0 3.0 11 !"-6.0 0.29 0.19 Insect Screen (default) W2 Window "�N 60d Will: (= specify:-, 0)N�;� L,- i U �1 3.0 1-0.0 �YY j S,) 11,1 ` L30 0 0.29 0.19 Insect Screen (default) U1 Window -,�l'OOd WaIL(-specify-Lf00) 4; 1� 10.0 0.29 0.19 Insect Screen (default) T2 Window 155d Wall (- specify -155) 6.0 10.0 1 60.0 0.34 0.21 Insect Screen (default) D60 Window 155d Wall (- specify -155) 6.0 10.0 1 60.0 1.19 0.59 Insect Screen (default) T1 Window 155d Wall (- specify -155) 6.0 10.0 1 60.0 0.29 0.19 Insect Screen (default) Y4 Window 155d Wall (- specify -155) - - 1 23.2 0.29 0.19 Insect Screen (default) T6 Window 170d Wall (- specify -170) 5.5 10.0 1 55.0 0.29 0.19 Insect Screen (default) T5 Window 170d Wall (- specify -170) 5.5 10.0 1 55.0 0.29 0.19 Insect Screen (default) T4 Window 170d Wall (- specify -170) 5.6 10.0 1 56.0 0.29 0.19 Insect Screen (default) T3 Window 170d Wall (- specify --170) 5.5 10.0 1 55.0 0.29 0.19 Insect Screen (default) D68 Window S Wall 2 (Back -180) 12.3 10.0 1 123.0 0.34 0.19 Insect Screen (default) Y3 Window S Wall 2 (Back -180) 11.3 3.0 1 33.9 0.29 0.19 Insect Screen (default) U4 Window 190d Wall 2 (- specify -190) - - 1 12.0 0.29 0.19 Insect Screen (default) V3 Window 240d Wall (- specify -240) 3.0 10.0 1 30.0 0.29 0.19 Insect Screen (default) D67 Window W Wall 2 (Right -270) -- - 1 48.0 0.34 0.19 Insect Screen (default) Y2 Window W Wall 2 (Right -270) 4.3 3.0 0.977 1 12.6 1 0.29 0.19 Insect Screen (default) Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Filler/Sandy Inv Ca cu'ation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml C*RF-01 - Page 9 of 17 Y1 Window W Wall 2 (Right -270) 11.5 12.3 1 141.5 0.29 0.19 Insect Screen (default) W5 Window W Wall 2 (Right -270) 2.0 4.0 1 8.0 0.29 0.19 Insect Screen (default) D64 Window 280d Wall (- specify -280) 3.5 10.0 1 35.0 0.34 0.21 Insect Screen (default) U6 Window 280d Wall (- specify --280) 2.3 10.0 1 23.0 0.29 0.19 Insect Screen (default) U3 Window 280d Wall (- specify -280) - - 1 53.6 0.29 0.19 Insect Screen (default) D66 Window 330d Wall (- specify -330) 7.0 10.0 1 70.0 0.34 0.19 Insect Screen (default) W3 Window 330d Wall (- specify -330) 2.2 10.0 1 22.0 0.29 0.19 Insect Screen (default) W1 Window 330d Wall (- specify -330) 3.8 10.0 1 38.0 0.29 0.19 Insect Screen (default) V4 Window 330d Wall (- specify -330) 3.8 10.0 1 38.0 0.29 0.19 Insect Screen (default) V2 Window 330d Wall (- specify -330) 2.2 10.0 1 22.0 0.29 0.19 Insect Screen (default) D65 Window 330d Wall (- specify -330) 7.0 10.0 1 70.0 0.34 0.19 Insect Screen (default) V1 Window 330d Wall (- specify -330) - -- 1 6.0 0.29 0.19 Insect Screen (default) C(*a"44�,iL4""4ERTS, nc. HEIRS PROVI DER Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI10E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I Project Name: Filler/Sandy Inv CkOD ation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1B-PAR-Corner.xml CF*RF-01 Page 10 of 17 OVERHANGS AND FINS 01 02 03 04 05 06ZO 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht.op Up DistL Bot Up Depth Top Up Dist R Bot Up H8 15 0.1 15 15 0 0 0 0 0 0 0 0 D10 15 0.1 15 15 0 0 0 0 0 0 0 0 0 H7 18 0.1 18 18 0 0 0 0 0 0 0 0 0 D09 12 0.1 12 12 0 0 0 0 0 0 0 0 0 H2 15 0.1 15 15 0 0 0 0 0 0 0 0 0 H4 15 0.1 15 15 0 0 0 0 0 0 0 0 0 G2 8 0.1 8 8 0 0 0 0 0 0 0 0 0 H1 15 0.1 15 15 0 0 0 0 0 0 0 0 0 H3 15 0.1 15 15 0 0 0 0 0 0 0 0 0 C1 6 0.1 6 6 0 0 0 0 0 0 0 0 0 A2 12 0.1 M,11 2 N 1,20ak U0.00,p%` - 0�,M 00 0 0 0 0 0 0 D01 12 '40.1 1231 f #12 I Lm QLAO A 0%*, of I'% 0 0 0 0 0 A3 12 �L_It0.1 lh 2U 1 `11 L0J I 10" 0f I t b" * 0 0 0 0 0 Al 12 '"%0�1 X12 M12C r0 0 0-0 %'j arf 0�-N I= 0rn� 0 0 0 0 0 D29 18 el "18 " ° "18' " 0 "`6 0� .4.- Cr 0 0 0 0 0 S2 18 0.1 18 18 0 0 0 0 0 0 0 0 0 K4 6 0.1 6 6 0 0 0 0 0 0 0 0 0 K6 6 0.1 6 6 0 0 0 0 0 0 0 0 0 N1 18 0.1 18 18 0 0 0 0 0 0 0 0 0 D19 10 0.1 10 10 0 0 0 0 0 0 0 0 0 D17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 K3 6 0.1 6 6 0 0 0 0 0 0 0 0 0 K5 6 0.1 6 6 0 0 0 0 0 0 0 0 0 D16 12 0.1 12 12 0 0 0 0 0 0 0 0 0 K2 12 0.1 12 12 0 0 0 0 0 0 0 0 0 D15 15 0.1 15 15 0 0 0 0 0. 0 0 0 0 K1 15 0.1 15 15 0 0 0 0 0 0 0 0 0 Window 15 0.1 15 15 0 0 0 0 0 0 0 0 0 Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JPOD Project Name: Filler/Sandy Inv culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml C*RF-01 - Page 11 of 17 D12 30 0.1 30 30 0 0 0 0 0 0 0 0 0 11 18 0.1 18 18 0 0 0 0 0 0 0 0 0 D28 18 0.1 18 18 0 0 0 0 0 0 0 0 0 S1 18 0.1 18 18 0 0 0 0 0 0 0 0 0 F1 8 0.1 8 8 0 0 0 0 0 0 0 0 0 D06 10 0.1 10 10 0 0 0 0 0 0 0 0 0 d02 8 0.1 8 8 0 0 0 0 0 0 0 0 0 D03 15 0.1 15 15 0 0 0 0 0 0 0 0 0 D04 8 0.1 8 8 0 0 0 0 0 0 0 0 0 U7 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W4 4 0.1 4 4 0 0 0 0 0 0 0 0 0 ' W2 8 0.1 8 8 0 0 0 0 0 0 0 0 0 T2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 D60 10 0.1 10 10 0 0 0 0 0 0 0 0 0 T1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 T6 8 0.1 �8 n 8l*;� 71=0F'; 0 on 0 0 0 0 0 0 T5 8 r�0.1 8 1118 ir�'=0 11 0 oil IG N 0r 0 0 0 0 0 T4 8 "�_0.1 i 8+, .. U `8 0,} U 0 J 17 0IJ U U 6,� 0 0 0 0 0 T3 8 �1 'H8 F 811; ,P0, ir0 1 0'" OR 0 0 0 0 0 D68 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Y3 18 0.1 18 18 0 0 0 0 0 0 0 0 0 V3 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Y2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Y1 10 0.1 10 10 0- 0 0 0 0 0 0 0 0 W5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 D64 10 0.1 10 10 0 0 0 0 0 0 0 0 0 U6 8 0.1 8 8 0 0 0 0 0 10 0 0 0 D66 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W3 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Wt 12 0.1 12 12 0 0 0 0 0 0 0 0 0 V4 12 0.1 12 12 0 0 0 0 0 0 0 0 0 V2 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D65 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD Project 'PE Filler/Sandy Inv Itculation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml C*RF-01 - Page 12 of 17 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Master Suite 1459 141 None 0.8 No • Cavity/ Frame: no insul. /2x4 Top Chrd Living/Kit/Din/Office 3209 182 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck. Wood Siding/sheathing/decking Attic RoofMaster Suite Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Guest 2 742 107 None 0.8 No • Inside Finish: Gypsum Board Casita Ceilings (below 346 None 0.8 No Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/ Frame: R-38 / 2x4 • Roof Deck. Wood Siding/sheathing/decking R-38 Roof Atticl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.041 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/ Frame: R-21 /2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking Attic RoofLiving/KIt/Dln/Office Attic Roofs W6d Framed Ceiing t S r•� 2x4 Top Chord£of Roof Truss '@ 24 in O.0 � ' none 0 644 Cavdy/Frame: no insul. /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) t Cavity/Frame: no insul. /2x4 Top Chrd Attic RoofGuest 1 Attic Roofs Wood, Ceiling ^ 2z4)Top'.Chord ofRoof Truss -@'24 in. O.C. none 0:644 Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGuest 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing., Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCasita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing. Light Roof (Asphak Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Covered Slab Master Suite 1459 141 None 0.8 No Covered Slab 2 Living/Kit/Din/Office 3209 182 None 0.8 No Covered Slab 3 Guest 1 429 31 None 0.8 No Covered Slab 4 Guest 2 742 107 None 0.8 No Covered Slab 5 Casita 2298 346 None 0.8 No Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE kOD Project Name: Filler/Sandy Inv Calculation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 7314.3 CF*RF-01 Page 13 of 17 WATER HEATING SYSTEMS 01 02 03 04 05 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/2 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% DHW Sys 3 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 3 1 _ .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type ^� ,4 Tank Type Tank Volume �(gaq Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas _ Large Stoiag`e �t 100 0.78 '9 85000 Btu/hr 0 0.03 DHW Heater 3 Natural Gas � Large Sto age fild(A I X0.78 85000-Btu/hr 0 0.03 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 — — — — — — DHW Sys 3 - 1/1 — — — — — — Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE . OD Project 'PE Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml CF�RF-01 - Page 4 of 17 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC 11 Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Cooling Component 1 System 13.1 16.7 Zonally Controlled Single Speed HVAC 2, 3, 4 & 52 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC 6 & 73 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC - HEATING UNIT TYPES 01 02'�� *� 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 97.2 AFUE Heating Component 2 CntdFurnace - Fuel -fired central furnace 97.2 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 97.4 AFUE /� it fC If a mil 14 It " It ._ HVAC - COOLING UNIT TYPES H If It R 01 02'�� *� r. 03 " " *4 '404 %=O' € '05 06 07 Name Verified Airflow Efficiency tj V I t: tt Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1 -hers -cool Cooling Component 2 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1 -hers -cool Cooling Component 3 SplitAirCond 13.5 18 Zonally Controlled Single Speed Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 150 Required Required Required Cooling Component 2 -hers -cool Required 150 Required Required Required Cooling Component 3 -hers -cool Required 150 Required Required Required Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version'- CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 4kOD Project Name: Filler/Sandy Inv Cation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml CF*RF-01 - Page 15 of 17 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 1 -hers -dist Air Distribution System 2 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 2 -hers -dist Air Distribution System 3 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 3 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Buried Design Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 6.0 Required Not Required Not Required Not Required — Air Distribution System 2 -hers -dist Required 6.0 Required Not Required Not RequiredNot Required — Air Distribution System 3 -hers -dist Required 6.01 __Required._ s Noott Required Not Required Not Required — If 0;;__. i! A£ 21 YF lF 3i 1V lF d HVAC -FAN SYSTEMS >� [ .� _ _ i , It �. I 02 01 i a d►^ �? +�^r rix *—,* *_.03 04 Name ` a"' Type `� i a ° '� *Fan Power(Watt /CFM) HERS Verification HVAC Fan 1 Required Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 HVAC Fan 3 -hers -fan Required 0.58 Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-08252015-744 Report Generated at: 2015-08-28 16:52:00 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D Project ame: Filler/Sandy Inv Clacu'O ation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1B-PAR-Corner.xml C*RF-01 Page 16 of 17 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 219.74 0.25 Default 0 Required "t1h1C'RTS, I nc HERS PROVIDER Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-08-28 16:52:00 CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD Project Name: Filler/Sandy Inv ation Date/Time: 16:49, Fri, Aug 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml CF.ORF-01 Page 7 of 17 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: 7&W15C'4z Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2015-08-28 17:03:27 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to -the enforcement,agency,for approval,with;this,building permit application. Responsible Designer Name:R r esponsible Designer Sig a tures %urv.�caZ�i C Tim ScottL ! ? �f Company: Date Signed: A � 2015 08 2817:0�3:27'i Scott Design and Title 24, Inc. Address: License: 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00 • r1 L - -J C RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Filler & Sandy Investments, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/28/2015 Project Address Lot 18, The Madison clubLa Quinta India California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,974 Addition n/a # of Units 1 INSULATION Construction Type Cavi(ft) Area Special Features Status Roof Wood Framed Attic R38 9,934 Cool Roof New Wall Wood Framed R 21 5,602 New Slab Unheated Slab -on -Grade - no insulation 8,137 Perim = 807' New Demising Wood Framed R 13 2,445 New FENESTRATION Orientation Area f 2 I Total Area: 4.774 Glazing Percentage: 47.9 U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.33 Exterior Shades Status Skylight 4.0 0.150 0.10 none none None New Skylight 4.0 0.150 0.10 none none None New Skylight 7.1 0.150 0.10 none none None New Front (N) 30.4 0.290 0.19 15.0 none Bug Screen New Front (N) 70.0 0.340 0.19 15.0 none Bug Screen New Rear (SVIO 68.0 0.290 0.19 18.0 none Bug Screen New Rear (SM 70.0 0.340 0.19 12.0 none Bug Screen New Rear (SVIO 176.0 0.290 0.19 15.0 none Bug Screen New Rear (SM 8.0 0.290 0.19 8.0 none Bug Screen New Right (NIM 78.0 0.290 0.19 15.0 none Bug Screen New Right (NiM 144.0 0.290 0.19 none none Bug Screen New Skylight 4.0 0.150 0.10 none none None New Skylight 4.0 0.150 0.10 none none None New Skylight 12.6 0.150 0.10 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 97% AFUE Split Air Conditioner 16.7 SEER Setback New 4 Central Furnace 97% AFUE Split Air Conditioner 16.7 SEER Setback New 2 Central Fumace 97% AFUE Split Air Conditioner 18.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 1 Ducted Ducted Conditioned 8.0 New HVAC 2, 3,4 & 5 Ducted Ducted Conditioned 8.0 New HVAC 6 & 7 Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 large Storage Gas 100 0.78 All Pipes Ins New 1 Large Storage Gas 100 0.78 All Pipes Ins New EnergyPro 6.7 by EnerqySoft User Number: 6712 Run Code: 2015-08-28716:53.47 /D: Page 20 of 54 • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Filler & Sandy Investments, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/28/2015 Project Address Lot 18, The Madison clubLa Quinta India California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,974 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status FENESTRATION Orientation Area(ft) I Total Area: 4,774 Glazing Percentage: 47.9%1New/Altered U -Fac SHGC Overhang Sidefins Average U -Factor: 0.33 Exterior Shades Status Skylight 4.0 0.150 0.10 none none None New Front (N) 58.0 0.290 0.19 6.0 none Bug Screen New Front (N) 252.0 0.290 0.19 12.0 none Bug Screen New Front (N) 60.0 1.190 0.59 12.0 none Bug Screen New Front (N) 144.0 0.340 0.19 18.0 none Bug Screen New Front (N) 20.4 0.290 0.19 18.0 none Bug Screen New Front (N) 17.1 0.290 0.19 none none Bug Screen New Front (NE) 49.7 0.290 0.19 none none Bug Screen New Front (NE) 100.0 0.290 0.19 6.0 none Bug Screen New Left (NE) 204.0 0.290 0.19 none none Bug Screen New Left (E) 27.5 0.290 0.19 18.0 none Bug Screen New Left (E) 50.0 0.340 0.19 10.0 none Bug Screen New Left (E) 27.7 0.290 0.19 none none Bug Screen New Left (SE) 129.9 0.290 0.19 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnemyPro6.7 by EnemySoft User Number: 6712 Run Code: 2015-08-28T16:53:47 ID: Page 21 of 54 • C n RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Filler & Sandy Investments, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/28/2015 Project Address Lot 18, The Madison clubLa Quinta India California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,974 Addition n/a # of Units 1 INSULATION Construction Type Cavi(ft) Area Special Features Status FENESTRATION Orientation Area(ft) I Total Area: 4,774 Glazin Percentage: 47.9 - New/Altered Average U -Factor: 0.33 U -Fac SHGC Overhang Sidefins Exterior Shades Status Left (SE) 30.0 0.340 0.21 6.0 none Bug Screen New Left (SE) 79.4 0.290 0.19 6.0 none Bug Screen New Left (SE) 93.0 0.340 0.19 12.0 none Bug Screen New Left (SE) 37.7 0.290 0.19 12.0 none Bug Screen New Rear (S) 11.4 0.290 0.19 none none Bug Screen New Rear (SVV) 165.0 0.340 0.19 15.0 none Bug Screen New Rear (SVtq 220.0 0.340 0.19 30.0 none Bug Screen New Rear (SVIq 102.0 0.290 0.19 30.0 none Bug Screen New Rear (SVV) 100.0 0.340 0.19 18.0 none Bug Screen New Right (SVt9 154.0 0.290 0.19 none none Bug Screen New Right (SVI9 33.0 0.340 0.21 none none Bug Screen New Right (Kq 144.0 0.340 0.19 18.0 none Bug Screen New Right (W) 20.4 0.290 0.19 18.0 none Bug Screen New Right (WJ 17.1 0.290 0.19 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqvPro6.7 by EnerqySoft User Number: 6712 Run Code: 2015-08-28T16:53:47 ID: Page 22 of 54 0 L' • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Filler & Sandy Investments, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/28/2015 Project Address Lot 18, The Madison clubLa Quinta India California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,974 Addition n/a # of Units 1 INSULATION Construction Type Cavi(ft) Area Special Features Status FENESTRATION Orientation Area(ft) I Total Area: 4774 Glazing Percentage: 47.9%1New/Altered U -Fac SHGC Overhang Sidefins Average U -Factor: 0.33 Exterior Shades Status Front (N) 27.0 0.290 0.19 none none Bug Screen New Right (SM 40.0 0.290 0.19 8.0 none Bug Screen New Right (NKK 90.0 0.340 0.21 10.0 none Bug Screen New Front (NE) 80.0 0.340 0.19 8.0 none Bug Screen New Right (NM 80.0 0.340 0.19 15.0 none Bug Screen New Front (NKK 80.0 0.340 0.21 8.0 none Bug Screen New Front (N) 50.0 0.290 0.19 4.0 none Bug Screen New Front (N) 39.0 0.290 0.19 none none Bug Screen New Left (NE) 6.0 0.290 0.19 4.0 none Bug Screen New Left (NE) 30.0 0.290 0.19 8.0 none Bug Screen New Left (E) 10.0 0.290 0.19 none none Bug Screen New Rear (SE) 60.0 0.340 0.21 10.0 none Bug Screen New Rear (SE) 60.0 1.190 0.59 10.0 none Bug Screen New Rear (SE) 60.0 0.290 0.19 10.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ene Pro6.7 by EnerqySoft User Number: 6712 RunCode: 2015-08-28716:53:47 ID: Pa a 23 of 54 C 1� RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Filler & Sandy Investments, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/28/2015 Project Address Lot 18, The Madison clubLa Quinta India California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,974 Addition n/a # of Units 1 INSULATION Construction Type Cavi Area (ft) Special Features Status FENESTRATION Orientation Area ft2 I Total Area: 4774 Glazing Percentage: 47.9 yo New/Altered Average U -Factor: 0.33 U -Fac SHGC Overhang Sidefins Exterior Shades Status Rear (SE) 23.2 0.290 0.19 none none Bug Screen New Rear (S) 221.0 0.290 0.19 8.0 none Bug Screen New Rear (S) 123.0 0.340 0.19 18.0 none Bug Screen New Rear (S) 33.9 0.290 0.19 18.0 none Bug Screen New Rear (S) 12.0 0.290 0.19 none none Bug Screen New Right (S1M 30.0 0.290 0.19 8.0 none Bug Screen New Right (Vtq 48.0 0.340 0.19 10.0 none Bug Screen New Right (Vtq 154.1 0.290 0.19 10.0 none Bug Screen New Right (VV) 8.0 0.290 0.19 2.0 none Bug Screen New Right (Ko 35.0 0.340 0.21 10.0 none Bug Screen New Right (Kq 23.0 0.290 0.19 8.0 none Bug Screen New Right (1" 53.6 0.290 0.19 none none Bug Screen New Front (NVt9 140.0 0.340 0.19 4.0 none Bug Screen New Front (NVtq 44.0 0.290 0.19 4.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro6.7 by EnemySoft User Number: 6712 Run Code: 2015-08-28716:53:47 ID: Page 24 of 54 • 1� RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Filler & Sandy Investments, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/28/2015 Project Address Lot 1B, The Madison clubLa Quinta India California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,974 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION I Total Area: 4,774 Glazing Percentage: 47.9 New/Altered Average U -Factor: 0.33 Orientation Area ft U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (NlAq 76.0 0.290 0.19 12.0 none Bug Screen New Front (NKK 6.0 0.290 0.19 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro6.7 by EnerqvSoft User Number: 6712 RunCode: 2015-08-28716:53:47 ID: Page 25 of 54 1. 2013' Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of § 10-11l(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF 1 R. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § I50.0(e)I C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013- Low -Rise Residential Mandatory Measures Summary §150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § I50.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013. Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § I50.0(k)IC: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § I50.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k) I F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to $110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 1� 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § I50.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, §130.0, §130.2, §130.4, §140.7 and 141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, $140.7 and §141.0. § I50.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in §110.9, § 130.0, § 130.2, § 130.4 § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0, § 130.1 § 130.4 § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I50.0(k)I2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § I 50.0(k) I 2B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §I 10.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of $110.10 b through § 110.10(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice §I 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §1 10.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 0 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name I.Filler & Sandy Investments, LLC Date 8/28/2015 System Name HVAC 1 Floor Area 1,459 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,183 Return Vented Lighting Return Air Ducts Return Fan Ventilation 243 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 78,000 20,877 1,647 546 18,054 Total Output Btuh 78,000 0 Output Btuhls ft 53.5 0 0 Cooling System 0 0 Output perSystem 58,000 9,316 3,058 243 11,904 Total Output Btuh 58,000 0 4,705 0 Total Output Tons 4.8 0 0 Total Output Btuh/s ft 39.8 Total Output s ft/Ton 301.9 1 30,193 29,958 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB160-59MN7A80-20 44,597 7,943 78,000 Airflow cfmis ft 1.37 Airflow cfmlTon 413.8 Outside Air % 12.2 % Total Adjusted System Output 44,597 7,943 78,000 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 243 cfm 72 OF 66 OF 103 OF 103 OF Heating Coil Supply Fan 2,000 cfm 103 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/66°F 80/66°F 59/58°F Outside Air 0 243 cfm Supply Fan Cooling Coil 59 / 58 OF 2,000 cfm 53.4% I'ROOM 76/64°F 76/64°F EnergyPro 6.7 by EnergySoff User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Page 30 of 54 SYSTEM HEATING AND COOLING LOADS SUMMARY e Fandy Investments, LLC Date 8/28/2015 System Name HVAC 2, 3, 4 & 5 Floor Area 6,217 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 4 COIL CFM Total Room Loads 5,024 Return Vented Lighting Return Air Ducts Return Fan Ventilation 1,036 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 78,000 87,192 7,020 2,592 84,654 Total Output Btuh 312,000 0 Output Btuh/s ft 50.2 0 0 Cooling System 0 0 Output perSystem 58,000 39,697 12,471 1,036 50,725 Total Output Btuh 232,000 0 0 126,890 19,491 0 Total Output Tons 19.3 0 Total Output Btuh/s ft 37.3 Total Output s ft/Ton 321.6 135,378 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 8,000 Carrier 24ANB160-59MN7A80-20 178,541 32,499 312,000 Total Adjusted System Output 178,541 32,499 312,000 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Airflow cfm/s ft 1.29 Airflow cfm/Ton 413.8 Outside Air % 13.0% Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF 103 OF 103 OF MOM 10 00. Outside Air Ar Pi ' �-I d 1,036 cfm Heating Coil Supply Fan 8,000 cfm 103 o F ROOM 72 OF 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 81/66°F 81/66°F 60/59°F Outside Air Ar V 1,036 cfm Supply Fan Cooling Coil 60 / 59 OF 8,000 cfm 53.9% [ROOM 76/64°F 76/64°F EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Page 31 of 54 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name filler & Sandy Investments, LLC Date 8/28/2015 System Name HVAC 6 & 7 Floor Area 2,298 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,210 Return Vented Lighting Return Air Ducts Return Fan Ventilation 383 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 78,000 40,718 2,595 1,101 47,236 Total Output Btuh 156,000 0 Output Btuhls ft 67.9 0 0 Cooling System 0 0 Output per System 47,200 14,673 5,363 383 18,749 Total Output Btuh 94,400 0 0 55,391 7,958 0 Total Output Tons 7.9 0 Total Output Btuhls ft 41.1 Total Output s ft/Ton 292.1 65,985 Air System CFM perSstem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 24ANB148-59MN7A080-20 73,642 11,315 156,000 Airflow cfm/s ft 1.39 Airflow cfm/Ton 406.8 Outside Air % 12.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 73,642 11,315 Aug 3 M1 156,000 F Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 383 cfm . 72 OF 66 OF 112 OF 112 OF ► ��� Heating Coil Supply Fan 3,200 cfm 112 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/66°F 80/66°F 59/58°F Outside Air 383 cfm Supply Fan Cooling Coil 3,200 cfm 76/64°F 59 / 58 OF 51.9% ROOM 76/64°F EnergyPro 6.7 by EnergySoR User Number: 6712 Run Code: 2015-08-28716:53:47 ID: Page 32 of 54 A& • ROOM LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 8/28/2015 System Name Floor Area HVAC 1 1,459 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name. Room Name Mult. CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible Master Suite I Master Ste Zone I 1 1 1,1831 20,8771 1,647 1,1831 20,8771 1,647 5461 54 PAGE TOTAL TOTAL ' 1,183 20,8771 1,6471 546 18,054 1,1831 20,8771 1,6471 546 18.054 Total includes ventilation load for zonal systems. EnergyPro 6.7 by EnemySoft User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Page 33 of 54 • • ROOM LOAD SUMMARY Project Name Filler & Sandy Investments, LLC Date 8/28/2015 System Name HVAC 2, 3, 4 & 5 Floor Area 6,217 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Livingh<&Din/Office Living Zone 1 4,011 69,615 5,698 4,011 69,615 5,698 2,015 65,814 Guest 1 Guest 1 1 282 4,899 484 282 4,899 484 144 4,709 Guest 2 Guest 2 1 731 12,679 838 731 12,679 838 433 14,130 ' Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL 1 5,024 5,024 87,192 87,192 7,020 7,020 2,592 84,654 2,592 84,654 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Page 34 of 54 r� 01 • ROOM LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 8/28/2015 System Name Floor Area HVAC 6 & 7 Z298 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Casita Casita 1 2210 40,718 2,595 2,210 40,718 2,595 1,1011 47,236 ' Total includes PAGE TOTAL TOTAL* 2,2101 40,7181 2,5951 1,101 47,236 2,210 40,718 2,595 1,101 47,236 • n U ROOM HEATING PEAK LOADS Project Name Filler & Sandy Investments, LLC Date 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Ste Zone Floor Area 1,459.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.1500 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F Btu/hr R-38 Roof Attic 1,443.9 46 = c 1,727 Skylight 15.1 46 104 R-21 Wall (W.21.2x6.16) 421.8 X 0.0690 46 c c c 1,339 530 Fixed 359.2 X X X 0.2900 46 4,792 3070 Door 140.0 0.3400 46 2,190 Slab -On -Grade perim = 141.0 0.7300 46 _ 4,735 'R-13 Wall 475.0 X X X X 0.1020 0 _ o = = 0 X X = = X X = = X X = X X = X = X = = = = X X X X X X = = = = X X X X = = = Page Total /60] X 46 AT X to another room 10.00 X 0.266 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,459 X Area 14,886 = 3,168 TOTAL HOURLY HEAT LOSS FOR ROOM 18,054 EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-28716:53.47 /D: Page 36 of 54 • • • ROOM HEATING PEAK LOADS Project Name Filler & Sandy Investments, LLC Date 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Zone Floor Area 5,046.0 ft' Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr = 6,006 = 170 = 6,097 = 17,876 = 3,284 = 14,326 = 985 c 6,112 _ 0 = = = = = = = = = = = c = c = = = = = = = 54,856 46 = 10,958 R-38 Roof Attic 5,021.4 X X X 0.0260 46 Skylight 24.6 0.1500 46 R-21 Wall (W.21.2x6.16) 1,921.0 0.0690 46 530 Fixed 1,340.0 X X X X 0.2900 46 Custom Entry Door 60.0 1.1900 46 3070 Door 916.0 0.3400 46 3500 Door 63.0 0.3400 46 Slab -On -Grade perim = 182.0 X X X X 0.7300 46 'R-13 Wall 945.0 0.1020 0 X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 5,046 X Area to another room 10.00 X 0.266 Ceiling Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 65,814 EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-28T16:53:47 /D: Page 37 of 54 / 1 U F-7 LJ ROOM HEATING PEAK LOADS Project Name Filler & Sandy Investments, LLC Date 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 Floor Area 429.0 It' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT *F X 46 X 46 X 46 = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof Attic 429.0 0.0260 513 R-21 Wall (W.21.2x6.16) 89.0 0.0690 282 530 Fixed 40.0 0.2900 534 3033 Door 90.0 0.3400 X 46 1,408 Slab -On -Grade perim = 31.0 0.7300 X X X 46 1,041 "R-13 Wall 455.0 0.1020 0 0 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 429 X Area another room 10.00 X 0.266 Height ACH Page Total /60] X AT 3,778 = 932 TOTAL HOURLY HEAT LOSS FOR ROOM 4,709 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Page 38 of 54 • • • ROOM HEATING PEAK LOADS Project Name Date Filler & Sandy Investments, LLC 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 2 Time of Peak Jan 1 AM Floor Area 742.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF, Conduction Area U -Value AT °F Btu/hr R-38 Roof Attic 742.0 X 0.0260 X 46 = 887 R-21 Wall (W.21.2x6.16) 759.5 X 0.0690 X 46 = 2,411 3070 Door 160.0 X 0.3400 X 46 = 2,502 530 Fixed 140.5 X 0.2900 X 46 = 1,874 3033 Door 80.0 X 0.3400 X 46 _ 1,251 Slab -On -Grade Perim = 107.0 X 0.7300 X 46 = 3,593 "R-13 Wall 285.0 X 0.1020 X 0 _ 0 X X = X X = X X X X o X X = X X = X X = X X = X X = X X = X X X X = X X - X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 12,519 Infiltration:[ 1.00 X 1.064 X 742 X 10.00 X 0.266 /60] X 46 = 1,611 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,130 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Page 39 of 54 • C C ROOM HEATING PEAK LOADS Project Name Filler & Sandy Investments, LLC Date 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 2298.0 It2 Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 0.0260 X 0.0690 X 0.2900 X 0.3400 X 1.1900 X 0.3400 X 0.7300 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X another room 10.00 X 0.266 Height ACH AT *F Btu/hr 46 = 2,748 46 = 6,507 46 _ 11,737 46 = 1,486 46 = 3,284 46 = 4,864 46 = 11,619 0 = 0 = = = = = = = = = = = = = = = Page Total 42,245 /60] X 46 = 4,990 AT R-38 Roof Attic 2,298.0 X R-21 Wall (W.21.2x6.16) 2,050.2 X 530 Fixed 879.8 X X 3500 Door 95.0 Custom Entry Door 60.0 X X X X 3070 Door 311.0 Slab -On -Grade perim = 346.0 'R-13 Wall 285.0 X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 2,298 X Area Ceiling TOTAL HOURLY HEAT LOSS FOR ROOM 47,236 EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-28716:53:47 /D: Page 40 of 54 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS Room Name Master Ste Zone Outdoor Dry Bulb Temperature Floor Area 1,459.0 ft-- Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Rancie: Oaaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation (VL9 (NE) (N) (StM (NW) 8/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,443.9 0.0260 77.0 85.0 0.0690 32.7 55.6 0.0690 31.0 41.2 0.0690 45.8 240.0 0.0690 51.2 475.0 0.1020 0.0 0.0 16.2 70.0 16.2 68.0 15.2 0.0 33.2 70.0 16.2 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnPQtrAtinn Skylight Skylight Skylight H8 D10 H7 D09 H2 H4 Orientation (IM (IM (tM (N) (N) (SM (SM (SlM (SIM Shaded Unshaded 112 OF 78 OF 34 OF Btulhr 2,891 192 119 130 01 1 4,1781 Area X X X X X X X X GLF + + + + + + + +0.0 Area X X X X X X X GLF = = = = = = = = 0.0 8.1 4.0 31.9 0.0 8.1 4.0 31.9 0.0 8.1 7.1 31.9 0.0 15.2 30.4 15.2 0.0 16.2 70.0 16.2 68.0 15.2 0.0 33.2 70.0 16.2 0.0 34.2 48.8X 15.2+ 0.0X 33.2= 24.0 15.2 33.2 Page Total Btu/hr 127 127 226 462 1,134 1,034 1,134 742 365 Internal Gain Btulhr Occupants 4.4 Occupants X 245 Btuh/occ. = 1,t Equipment 1,459 Floor Area X 0.50 w/sqft = Infiltration: 1.064 X 0.88 X 66.86 X 36 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20.8771 Latent Gain Btu/hr Occupants 4 4 Occupants X 155 Btuh/occ. = 678 Infiltration: 4.771 X 0.88 X 66.86 X 0.00344 = 969 Air Sensible CFM ELA AW EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Page 41 of 54 1 i • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Ste Zone Outdoor Dry Bulb Temperature 112 OF Floor Area 1,459.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr G2 (SIM 8.0 X 15.2 + 0.0 X 33.2 = 122 H1 (NM 34.0 X 15.2 + 18.0 X 37.4 = 1,190 H3 (NIM 26.0 X 15.2 + 0.0 X 37.4 = 395 G1 (NIM 0.0 X 15.2 + 102.0 X 37.4 = 3,814 X + X = X + X = X + X = X + X = X + X = Page Total 5,521 Internal Gain Btu/hr Occupants 4 4 Occupants X 245 Btuh/occ. = 1,072 Equipment 1,459 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.88 X 66.86 X 36 = 2,264 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,877 Latent Gain Btu/hr Occupants 4 4 Occupants X 155 Btuh/occ. = 678 Infiltration: 4,771 x 0.88 x 66.86 x 0.00344 — 969 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 678 EneMyPro 6.7 by EnemySoft User Number- 6712 RunCode: 2015-08-28716:53:47 ID: Page 42 of 54 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS Room Name Living Zone Outdoor Dry Bulb Temperature Floor Area 5,046.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranae: Onanue Surfarps R-38 Roof Affic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (►M (N) (NE) (E) (SE) (S) (S) (SM (S -K9 Date 8/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = c = = = = = 5,021.4 0.0260 56.0 261.5 0.0690 23.0 46.3 0.0690 26.3 474.8 0.0690 33.0 300.5 0.0690 31.9 118.6 0.0690 26.0 105.0 0.0690 27.1 212.8 0.0690 28.8 73.0 0.06901 1 31.2 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Skylight Skylight Skylight Skylight C1 A2 D01 A3 Al Oriantatinn (1/109 W (►M (W) (N) (N) (N) (N) (N) Page Total Shaded Unshaded 112 OF 78 OF 34 OF Btu/hr 7,311 415 84 1,081 661 213 196 423 1 10,5421 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = - = c = = = - 0.0 6.8 4.0 20.4 0.0 6.8 4.0 20.4 0.0 6.8 12.6 20.4 0.0 6.8 4.0 20.4 0.0 12.9 58.0 12.9 0.0 12.9 50.0 12.9 0.0 45.7 60.0 45.7 0.0 12.9 179.0 12.9 0.0 12.9 23.0 12.9 Page Total Btu/hr 81 81 257 81 745 643 2,742 2,300 296 7.226 Internal Gain Btu/hr Occupants 15.1 Occupants X 245 Btuh/occ. = 3,709 Equipment 5,046 Floor Area X 0.50 W/sgft = 8,611 Infiltration: 1.064 X 0.88 X 231.25 X 36 = 7,829 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,6151 Latent Gain Btu/hr Occupants 15.1 Occupants X 155 Btuh/occ. = 2,34E Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.3461 6.7 s • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Zone Outdoor Dry Bulb Temperature 112 OF Floor Area 5,046.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-21 Wall (W..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation (►M (NW) (N) Area X X X X X- X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 98.5 0.0690 33.0 152.0 0.0690 31.5 78.0 0.0690 29.0 945.0 0.1020 0.0 5.7 12.9 0.0 12.9 5.7 12.9 0.0 12.9 5.7 12.9 0.0 12.9 4.0 16.2 0.0 12.9 64.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration D29 S2 P1 P2 P12 L4 K4 K6 P11 Internal Gain Orientation (N) (N) (N) (N) (N) (NE) (NE) (NE) (NE) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 13.9 144.0 13.9 0.0 12.9 20.4 12.9 0.0 12.9 5.7 12.9 0.0 12.9 5.7 12.9 0.0 12.9 5.7 12.9 0.0 12.9 4.0 16.2 0.0 12.9 64.0 16.2 0.0 12.9 36.0 16.2 0.0 12.9 5.7 16.2 Page Total 01 1,994 262 73 73 585 93 15.1 Occupants X 245 Btuh/occ. - 3,709 5,046 Floor Area X 0.50 w/sqn = 8,611 Infiltration: 1.064 X 0.88 X 231.25 X 36 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,6151 Latent Gain Btu/hr Occupants 15.1 Occupants X 155 Btuh/occ. = 2,346 Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351 Air Sensible CFM ELA AW W1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS Room Name Living Zone Outdoor Dry Bulb Temperature Floor Area 5,046.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranae: ue Surfaces Orientation Date 8/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = - 0.0 12.9 68.0 19.5 0.0 12.9 68.0 19.5 0.0 12.9 68.0 19.5 27.5 12.9 0.0 24.1 39.5 13.9 10.5 25.1 0.0 12.9 22.0 24.1 0.0 12.9 5.7 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FwnPctratinn C2 C3 C4 N1 D19 M1 P10 L3 D17 Orientation (NE) (NE) (NE) (E) (E) (E) (E) (SE) (SE) Shaded Unshaded Area X X X X X X X X1 X GLF + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 0.0 12.9 68.0 19.5 0.0 12.9 68.0 19.5 0.0 12.9 68.0 19.5 27.5 12.9 0.0 24.1 39.5 13.9 10.5 25.1 0.0 12.9 22.0 24.1 0.0 12.9 5.7 24.1 0.0 12.9 60.0 17.9 21.2 14.61+ 8.8 20.1 Page Total 112 OF 78 OF 34 OF Btu/hr 0 Btu/hr 1,328 1,328 1,328 353 811 531 138 1,072 7 Internal Gain Btu/hr Occupants 15.1 Occupants X 245 Btuh/occ. 3,709 Equipment 5,046 Floor Area X 0.50 w/sgft = 8,611 Infiltration: 1.064 X 0.88 X 231.25 X 36 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,61 Latent Gain Btu/hr Occupants 15.1 Occupants X 155 Btuh/occ. = 2,34E Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351 Air Sensible CFM ELA OW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.3461 EneravPro 6.7 by EnerovSoR User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Paae 45 of 54 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS Room Name Living Zone Outdoor Dry Bulb Temperature Floor Area 5,046.Oft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Range: Surfaces Orientation Date 8/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = c 44.5X 12.9+ 5.9 17.9= 29.0 12.9 0.0 17.9 93.0X 13.9+ 0.0X 18.9= 37.7 12.9 0.0 17.9 0.0 12.9 5.7 17.9 0.0 12.9 5.7 17.9 0.0 12.9 5.7 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fpnpstratinn K3 K5 D16 K2 P9 P8 P6 P7 D15 Orientation (SE) (SE) (SE) (SE) (SE) (SE) (S) (S) (SW) Shaded Unshaded Area X X X X X X X GLF + + + + + + + Area X X X X X X X i X GLF = = = = = = c 44.5X 12.9+ 5.9 17.9= 29.0 12.9 0.0 17.9 93.0X 13.9+ 0.0X 18.9= 37.7 12.9 0.0 17.9 0.0 12.9 5.7 17.9 0.0 12.9 5.7 17.9 0.0 12.9 5.7 12.9 0.0 12.9 5.7 12.9 165.0 13.9 0.0 16.3 Page Total 112 OF 78 OF 34 OF Btulhr 677 373 1,288 484 102 102 74 74 2,285 Internal Gain Btu/hr Occupants 15.1 Occupants X 245 Btuh/occ. = 3,709 Equipment 5,046 Floor Area X 0.50 w/sgft = 8,611 Infiltration: 1.064 X 0.88 X 231.25 X 36 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,615 Latent Gain Btu/hr Occupants 15.1 Occupants X 155 Btuh/occ. = 2,34E Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.3461 EnerovPro6.7 by EnerovSoft User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Paae 46 of 54 1 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Room Name Floor Area Indoor Dry Bulb 1 Opaque Surfaces V DESIGN CONDITIONS Living Zone Outdoor Dry Bulb Temperature 5,046.0 ft2 Outdoor Wet Bulb Temperature rature 76 OF Outdoor Dailv Ranae: Orientation Date 8/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 79.2 12.9 0.0 15.3 24.0 12.9 0.0 15.3 220.0 13.9 0.0 16.3 0.0 12.9 102.0 15.3 100.0 13.9 0.0 16.3 0.0 12.9 68.0 17.4 0.0 14.6 33.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration K1 Window D12 J1 11 C6 D05 C5 D28 Internal Gain Oripntatinn (SIM (SIM (SIM (S K9 (SIM (SIM (SIM (SIM t'►M Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 79.2 12.9 0.0 15.3 24.0 12.9 0.0 15.3 220.0 13.9 0.0 16.3 0.0 12.9 102.0 15.3 100.0 13.9 0.0 16.3 0.0 12.9 68.0 17.4 0.0 14.6 33.0 19.6 0.0 12.9 68.0 17.41 144.0 13.9 1 0.0 25.1 Page Total 15.1 Occupants X 245 Btuh/occ. 5,046 Floor Area X 0.50 W/sgft Infiltration: 1.064 X 0.88 X 231.25 X 36 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 15.1 Occupants X 1 155 Btuh/occ. Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = Air Sensible CFM ELA AW •I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 112 OF 78 OF 34 OF Btu/hr tnumr 1,018 308 3,047 1,561 1,385 1,182 647 1,182 1,9941 Btu/hr 3,709 8,611 7,829 69,615 Btu/hr 2,346 3,351 2.346 C • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Zone Outdoor Dry Bulb Temperature 112 OF Floor Area 5,046.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btulhr X X = X X X X = X X = X X = X X = X X = X X = X X _ Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr S1 (IM 20.4 X 12.9 + 0.0 X 24.1 = 262 P3 (IM 0.0 X 12.9 + 5.7 X 24.1 = 138 P4 (IM 0.0 X 12.9 + 5.7 X 24.1 = 138 P5 (IM 0.0 X 12.9 + 5.7 X 24.1 = 138 R1 (NIM 0.0 X 12.9 + 18.0 X 21.3 = 383 81 (N) 0.0 X 12.9 + 13.5 X 19.0 = 256 B2 (N) 0.0 X 12.9 + 13.5 X 19.0 c 256 X + X = X 1+1 X = Page Total 1,569 Internal Gain Btu/hr Occupants 15.1 Occupants X 245 Btuh/occ. = 3,709 Equipment 5Floor Area X 0.50 w/sgft = 8,611 Infiltration: 1.064 X 0.88 X 231.25 X 36 = 7,829 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,615 Latent Gain Btu/hr Occupants 15.1 Occupants X 155 Btuh/occ. Infiltration: 4.771 X 0.88 X 231.25 X 0.00344 = 3,351 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,346 EnemyPro 6.7 by EnemySoft User Number., 6712 RunCode: 2015-08-28716:53:47 ID: Page 48 of 54 C: • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 1 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 429.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (W) 429.0 X 0.0260 X 56.0 = 625 R-21 Wall (W.21.2x6.16) (SIM 25.0 X 0.0690 X 31.2 = 54 R-21 Wall (W.21.2x6.16) (NW) 5.0 X 0.0690 X 31.5 = 11 R-21 Wall (W.21.2x6.16) (NIM 59.0 X 0.0690 X 29.9 = 122 `R-13 Wall 455.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 811 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr Ff (SW) 40.0 X 12.9 + 0.0 X 17.4 = 514 D06 (NW) 31.1 X 14.6 + 58.9 X 23.9 = 1,861 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 2.37 Internal Gain Btu/hr Occupants 1.3 Occupants X 245 Btuh/occ. = 315 Equipment 429 Floor Area X 0.50 w/sgft = 732 Infiltration: 1.064 X 0.88 X 19.66 X 36 = 666 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,899 Latent Gain Btu/hr Occupants 13 Occupants X 155 Btuh/occ. = 199 Infiltration: 4,771 X 0.88 X 19.66 X 0.00344 = 285 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 199 EnerqyPro6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-28T16:53.47 /D: Page 49 of 54 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 2 Outdoor Dry Bulb Temperature Floor Area 742.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF I Outdoor Dailv Ranae: ODaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation (M (NE) (SE) (S K9 (SVtq (NKK (NW) Date 8/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = 742.0 0.0260 56.0 100.0 0.0690 26.3 286.5 0.0690 31.9 50.0 0.0690 28.8 137.0 0.0690 31.2 101.0 0.0690 31.5 85.0 0.0690 29.9 285.0 0.1020 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration d02 E1 D1 D2 D03 E2 E2 D04 (NE) (NE) (SE) (SK9 (NW) (NKK (NW) (NW) 112 OF 78 OF 34 OF Btu/hr 1,080 182 630 99 295 219 175 0 1 2,6821 Shaded Area 0.0X 0.0 X 0.0 X 0.0 X Unshaded GLF Area 13.9+ 80.0X 12.9 + 40.0 12.9 + 58.5 12.9 + 18.0 13.9 + 38.1 12.9 + 8.0 12.9 + 16.0 14.6 + 80.0 +1 X X X X X X X X GLF 17.2= 16.2 c 17.9 = 17.4 = 22.3 = 21.3 = 21.3 = 21.3 = Page Total 41.9 X 0.0 X 0.0 X 0.0 X X Btu/hr 1,380 650 1,045 313 1,429 170 340 1,708 7 Internal Gain Btulhr Occupants 2.2 Occupants X 245 Btuh/occ. = 545 Equipment 742 Floor Area X 0.50 w/sgft = 1,266 Infiltration: 1.064 X 0.88 X 34.00 X 36 = 1,151 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,6791 Latent Gain Btu/hr Occupants 2.2 Occupants X 155 Btuh/occ. = 345 Infiltration: 4,771 X 0.88 X 34.00 X 0.00344 = 493 Air Sensible CFM ELA AW I EnemyPro 6.7 by EnergySoft User Number., 6712 RunCode: 201 5-08-2 8 77 6:53:47 ID: Page 50 of 54 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name ' Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS 8/28/2015 mName Casita Outdoor Dry Bulb Temperature 112 °F rtoorArea 2,298.0 f1Z Outdoor Wet Bulb Temperature 78 °F or Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Ooaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (1N.21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W.21.24. Orientation (1/10 (N) (NE) (NE) (E) (SE) (S) (S) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = 2,298.01 0.0260 56.0 131.0 0.0690 24.3 154.0 0.0690 30.3 156.0 0.0690 30.8 540.0 0.0690 32.6 60.8 0.0690 28.8 55.0 0.0690 27.1 87.1 0.0690 12.9 58.0 0.0690 27.1 Page Total L Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration OriPntatinn Area GLF Area GLF U7 U5 U2 W4 W2 U1 T2 D60 T1 Internal Gain (N) (N) (N) (NE) (NE) (E) (SE) (SE) (SE) 0.0 X X X X X X X X X 12.9 + + + + + + + + + 50.0 X 14.2 X 14.2 X 14.2 X 20.7 X 20.7 X 23.7 X 17.3 X 53.3 X 15.3 Page Total c = = c = = = = - 0.0 12.9 27.0 0.0 12.9 12.0 1.9 12.9 4.1 6.1 12.9 23.9 0.0 12.9 10.0 60.0 14.6 0.0 60.0 45.7 0.0 60.0 12.9 0.0 6 9 Occupants X 245 Btuh/occ. _ 2,298 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 0.88 X 105.31 X 36 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 6 9 Occupants X 1 155 Btuh/occ. _ 'Infiltration: 4,771 X 0.88 X 105.31 X 0.00344 = Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR RO Btu/hr 3,346 220 322 331 1,213 121 103 156 108 5,921 710 384 170 109 573 237 876 2,742 771 Btu/hr 1,689 3,922 3,566 40,718 Btu/hr 1,069 1,526 1.069 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ' ROOM INFORMATION DESIGN CONDITIONS Date 8/28/2015 Name Casita Outdoor Dry Bulb Temperature 112Area r 2,298.0ft2 Outdoor Wet Bulb Temperature 78 °F r Dry Bulb Temperature 76 OF Outdoor Daily Ranqe: 34 OF ODaaue Surfaces R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation (SW) (tM (W) (NW) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' _ = = = = = = = = 120.0 0.0690 31.7 225.9 0.0690 33.0 198.4 0.0690 32.4 264.0 0.0690 29.3 285.0 0.1020 0.0 12.9 0.0 13.9 55.0 12.9 0.0 13.9 123.0 13.9 0.0 13.9 33.9 12.9 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fanactratinn Y4 T6 T5 T4 T3 D68 Y3 U4 V3 Orientation (SE) (S) (S) (S) (S) (S) (S) (S) (SM Shaded Unshaded Area X X X X X X X GLF + + + + + + + Area X X X X X X X GLF = = = = = - 0.0 12.9 23.2 15.3 55.0X 12.9+ 0.0X 13.9= 55.0X 12.9+ 0.0X 13.9= 56.0 12.9 0.0 13.9 55.0 12.9 0.0 13.9 123.0 13.9 0.0 13.9 33.9 12.9 0.0 12.9 0.0 12.9 12.0 13.9 30.0 12.9 0.0 17.7 Page Total 514 443 534 0 1,754 Btulhr 355 707 707 720 707 1,704 436 166 386 5,886 Internal Gain Btu/hr Occupants fi.9 Occupants X 245 Btuh/occ. = 1,689 Equipment 2,298 Floor Area X 0.50 w/sgft = 3,922 Infiltration: 1.064 X 0.88 X 105.31 X 36 = 3,566 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40.718 Latent Gain Btu/hr Occupants 6 9 Occupants X 155 Btuh/occ. = 1,069 Infiltration: 4,771 X 0.88 X 105.31 X 0.00344 = 1,526 Air Sensible CFM ELA AW 0 1 I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 It , 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Filler & Sandy Investments, LLC ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature Floor Area 2,298.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranoe: Opaque Surfaces Orientation Date 8/28/2015 Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration D67 Y2 Y1 W5 D64 U6 U3 D66 W3 AriPntatinn (►M (tM ftM NO (tM NO (NVIO (NI/19 Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 13.9 48.0 25.1 12.6 12.9 0.0 24.1 90.9 12.9 50.6 24.1 3.0 12.9 5.0 24.1 21.4 14.6 13.6 25.8 11.2 12.9 11.8 23.0 0.0 12.9 53.6 23.0 0.0 13.9 70.0 20.0 0.0 12.9 22.0 1 19.0 Page Total 112 °F 78 °F 34 OF 0 tstumr 1,206 162 2,389 159 663 415 1,232 1,397 417 8,041 Internal Gain Btu/hr Occupants . 6 9 Occupants X 245 Btuh/occ. = 1,669 Equipment 2,298 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.88 X 105.31 X 36 = 3,566 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,71E Latent Gain Btu/hr Occupants 6 9 Occupants X 155 Btuh/occ. = 1,069 Infiltration: 4,771 Air Sensible X 0.88 CFM X 105.31 X 0.00344 = ELA AW 1,526 1 EnemyPro 6.7 by EnemySoft User Number., 6712 Run Code: 2015-08-28716:53:47 /D: Page 53 of 54 1 L` 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Filler & Sandy Investments, LLC 1 8/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 2,298.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr W1 (NVt9 0.01 X 12.9 + 38.0 X 19.0 = 721 V4 (NVtq 0.0 X 12.9 + 38.0 X 19.0 = 721 V2 (NVt9 0.0 X 12.9 + 22.0 X 19.0 = 417 D65 (NIA9 0.0 X 13.9 + 70.0 X 20.0 = 1,397 Vl (NVt9 0.0 X 12.9 + 6.0 X 19.0 = 114 X + X = X + X = X + X = X +1 X = Page Total 3,369 Internal Gain Btu/hr Occupants 6.9 Occupants X 245 Btuh/occ. = 1,689 Equipment 2,298 Floor Area X 0.50 w/sgft = 3,922 Infiltration: 1.064 X 0.88 X 105.31 X 36 = 3,566 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,716 Latent Gain Btu/hr Occupants 6 9 Occupants X 155 Btuh/occ. = 1,069 Infiltration: 4,771 X 0.88 X 105.31 X 0.00344 = 1,526 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,069 Ene Pro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-28716:53:47 /D: Page 54 of 54