BRES2015-0341 Title 24r.
BUILDING ENERGY ANALYSIS REPORT
RECEIVE
PROJECT: SEP 0 3 2015
Filler & Sandy Investments, LLC CITY OF LA QUINTA
Lot 1 B, The Madison Club C®MMUNM DE'vELOPMEN
La Quinta, CA 92253
LA
Pro' Designer:
Project es gner.
PAR Development
42-240 Green Way, Suite C
Palm Desert, CA 92211
(760) 341-5716
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 92211
(760) 200-478[DATE
) ®F ��
BUILDING S '47
pFj y DEPT.
CR CONST UC�
Z6
BY
Job Number:
Date:
8/31/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC —www.energysoft.com.
EnemvPro 6.7 by EnemvSoft User Number: 6712 ID:
r(00000'
CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE a OD
Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1 B-PAR-Corner.xml
CRF -01
Page 1 of 17
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Filler/Sandy Inv
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location Lot 1 B, The Madison clubl-a Quinta
Compliance Margin
Percent Improvement
04
City Indian Wells
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 9974
15
Number of Zones 5
16
Slab Area (ft) 8137
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (ft) N/A
21
Glazing Percentage (%) 47.9%
COMPLIANCE RESULTS
01 Building Complies with Computer Performan6T4
�c { " 'it it e� rr
02 This building incorporates features'tthat require field testing and/or verification by a certifed)HERS rater,underthe supervision of a CEC-approved HERS provider.
1 i...., i t_. i, 3 i r. _4 �.
03 This building incorporates one or�more Special Features shown below � . ^,* hf
F ii tr:: f"a -.:.1► �-" � 'e...d` WP fir �,.,�' iG �
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.19
4.27
-1.08
-33.9%
Space Cooling
84.76
77.21
7.55
8.9%
IAQ Ventilation
0.98
0.98
0.00
0.0%
Water Heating
2.57
8.92
-6.35
-247.1%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
91.50
91.38
0.12
0.1%
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Cathedral Ceiling
• Window overhangs and/or fins
HERS FEATURE SUMMARY
C*RF-01
Page 2of17
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
• Building Envelope Air Leakage
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts entirely in conditioned space
Cn,,::4 Domestic Hot Water System Verifications:
• —None— � RT", �
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 124.86 124.74 0.12 0.1%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Filler/Sandy Inv
9974
1
15
5
0
2
Registration Number: 215-N6307872A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-08-28 17:03:27
Report Version - CF1R-08252015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-08-28 16:52:00
CERTI'fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1B-PAR-Corner.xml
C*RF-01 -
Page 3 of 17
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
HVAC 11
1459
10
DHW Sys 1
Living/Kit/Din/Office
Conditioned
HVAC 2, 3, 4 & 52
5046
10
DHW Sys 1
Guest 1
Conditioned
HVAC 2, 3, 4 & 52
429
10
DHW Sys 1
Guest 2
Conditioned
HVAC 2, 3, 4 & 52
742
10
DHW Sys 1
Casita
Conditioned
HVAC 6 & 73
2298
10
DHW Sys 3
C rt* RTS,, i Cp* d It
0
HERS �„
n i
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTl*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE C*OD
Project Name: Filler/Sandy Inv Ca elation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1 B-PAR-Corner.xml
C -*RF -01 -
Page 4 of 17
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation Gross Area (ft2)
Window & Door Area (ftz)
Tilt (deg)
25d Wall
Master Suite
R-21 Wall (W.21.2x6.16)
25
- specify -
85
90
115d Wall
Master Suite
R-21 Wall (W.21.2x6.16)
0
Front
156
100.4
90
205d Wall
Master Suite
R-21 Wall (W.21.2x6.16)
205
- specify -
260
218.8
90
295d Wall
Master Suite
R-21 Wall (W.21.2x6.16)
295
- specify -
420
180
90
Roof 3
Master Suite
R-38 Roof Attic
1443.9
N Wall
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
0
Front
813
551.5
90
25d Wall 2
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
25
- specify -
156
109.69
90
50d Wall
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
50
- specify -
204.1
204
90
E Wall
Living/KiUDin/Office
R-21 Wall (W.21.2x6.16)
90
Left
580
105.2
90
115d Wall 2
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
115
- specify -
612
311.501
90
S Wall
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
180
Back
130
11.4.
90
190d Wall
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
190
- specify -
105
90
205d Wall 2
Living/Kit/Din/Officef"^f
R 21 Wall (W.21:2x616) (j-206
specify-
903
690.189
90
230d Wall
Living/Kit/Din/Officei
,-.�� R241iWall (W 21:2x6:16)
`230
�- 'specify
242
169
90
W Wall
Living/Kit/Din/Office `� ` R=21�Wall{W21:2x&i16)3
z "Z276
U tRigFit V
280
181.5
90
295 Wall
Living/Kit/Din/Office "'
Ra21 Wall,(W.21:2z6.16)(
295 f
specify- i
170
18
90
340d Wall
Living/Kit/Din/Office
R-21 Wall (W.21.2x6.16)
340
- specify -
105
27
90
Roof 4
Living/Kit/Din/Office
R-38 Roof Attic
5021.4
230d Wall 2
Guest 1
R-21 Wall (W.21.2x6.16)
230
- specify -
65
40
90
295d Wall 2
Guest 1
R-21 Wall (W.21.2x6.16)
295
- specify -
95
90
90
320 Wall
Guest 1
R-21 Wall (W.21.2x6.16)
320
- specify -
59
90
Roof 5
Guest 1
R-38 Roof Attic
429
25d Wall 3
Guest 2
R-21 Wall (W.21.2x6.16)
25
- specify -
220
120
90
115d Wall 3
Guest 2
R-21 Wall (W.21.2x6.16)
115
- specify -
345
58.5
90
205d Wall 3
Guest 2
R-21 Wall (W.21.2x6.16)
205
- specify -
50
90
230d Wall 3
Guest 2
R-21 Wall (W.21.2x6.16)
230
- specify -
155
18
90
295d Wall 3
Guest 2
R-21 Wall (W.21.2x6.16)
295
- specify -
205
104
90
320d Wall
Guest 2
R-21 Wall (W.21.2x6.16)
320
- specify -
165
80
90
Roof 6
Guest 2
R-38 Roof Attic
742
10d Wall
Casita
R-21 Wall (W.21.2x6.16)
10
- specify -
220
89
90
Registration Number: 215•N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI'fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD
Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
CFORF-01 -
Page 5 of 17
60d Wall
Casita
R-21 Wall (W.21.2x6.16)
60
- specify -
190
36
90
65d Wall
Casita
R-21 Wall (W.21.2x6.16)
65
- specify -
156
Zone
90
100d Wall
Casita
R-21 Wall (W.21.2x6.16)
100
- specify -
550
10
90
155d Wall
Casita
R-21 Wall (W.21.2x6.16)
155
- specify -
264
203.2
90
170d Wall
Casita
R-21 Wall (W.21.2x6.16)
170
- specify -
276
221
90
S Wall 2
Casita
R-21 Wall (W.21.2x6.16)
180
Back
244
156.9
90
190d Wall 2
Casita
R-21 Wall (W.21.2x6.16)
190
- specify -
70
12
90
240d Wall
Casita
R-21 Wall (W.21.2x6.16)
240
- specify -
150
30
90
W Wall 2
Casita
R-21 Wall (W.21.2x6.16)
270
Right
436
210.053
90
280d Wall
Casita
R-21 Wall (W.21.2x6.16)
280
- specify -
310
111.6
90
330d Wall
Casita
R-21 Wall (W.21.24.16)
330
- specify -
530
266
90
Roof 7
Casita
R-38 Roof Attic
2298
OPAQUE SURFACES - Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Type
Orientatio.
n N ._.__
A aft)
,r�
Skylight -Area
(ft2j_
Roof Rise
(z in 12)
Roof
_Pitch1.
Roof Tilt
(deg)
Roof
Reflectance
Roof
Emittance
Framing
Factor
Roof
Master Suite
\R-38 Roof Attic1
1 Right I;
} 15t2''
15.1-)) N
1121'1 1.
((0.17
9.46
0.65
0.88
0.1
Roof 2
Living/Kit/Din/Office
I -N'RQg38 RoofAtticl :::'
�, kig�f K
24.7
24:fi L
2-0
17y
9.46
0.65
0.88
0.1
v i a €._ a a. _.e r- & It 6_-.T is a a_0 Z_ I'%
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Unventilated
2
0.65
0.88
No
Yes
Attic Living/Kit/Din/Office
Attic RoofLiving/Kit/Din/Office
Unventilated
2
0.65
0.88
No
Yes
Attic Guest 1
Attic RoofGuest 1
Unventilated
3
0.65
0.88
No
Yes
Attic Guest 2
Attic RoofGuest 2
Unventilated
3
0.65
0.88
No
Yes
Attic Casita
Attic RoofCasita
Unventilated
2
0.65
0.88
No
Yes
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
` CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTIIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1B-PAR-Corner.xml
CIORF-01 -
Page 6 of 17
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth) Width (ft) Height (ft)
Multipli
er
Area
(ft)
U -factor
SHGC
Exterior Shading
H8
Window
115d Wall (Front -0)
3.8
8.0
1
30.4
0.29
0.19
Insect Screen (default)
D10
Window
115d Wall (Front -0)
7.0
10.0
1
70.0
0.34
0.19
Insect Screen (default)
H7
Window
205d Wall (- specify -205)
8.5
8.0
1
68.0
0.29
0.19
Insect Screen (default)
D09
Window
205d Wall (- specify -205)
7.0
10.0
1
70.0
0.34
0.19
Insect Screen (default)
H2
Window
205d Wall (- specify -205)
6.1
8.0
1
48.8
0.29
0.19
Insect Screen (default)
H4
Window
205d Wall (- specify -205)
6.0
4.0
1
24.0
0.29
0.19
Insect Screen (default)
G2
Window
205d Wall (- specify -205)
2.0
4.0
1
8.0
0.29
0.19
Insect Screen (default)
1-11
Window
295d Wall (- specify -295)
6.5
8.0
1
52.0
0.29
0.19
Insect Screen (default)
H3
Window
295d Wall (- specify -295)
6.5
4.0
1
26.0
0.29
0.19
Insect Screen (default)
G1
Window
295d Wall (- specify -295)
-
-
1
102.0
0.29
0.19
Insect Screen (default)
Skylight
Skylight
Roof (Right -270)
1
4.0
0.15
0.10
Skylight 2
Skylight
Roof;(Right-270)'") j5^-,_„3 r,= tr �zi f,
1
4.0
0.15
0.10
Skylight 3
Skylight
Roof (Right 270)N Y 1�= N: f
11
yti I
Z^7.1
0.15
0.10
C1
Window
N 1Na�ll-(1 %„nt-0) j� �. �F ,i �
5 8
10.0
1 58 0
0.29
0.19
Insect Screen (default)
A2
Window
�*.�{� N Wall (Front?0) r p o
2co i
c 10.0 r 2.5'
556.6
0.29
0.19
Insect Screen (default)
D01
Window
N Wall (Front -0)
6.0
10.0
1
-60.0
1.19
0.59
Insect Screen (default)
A3
Window
N Wall (Front -0)
10.5
1.7
10.028
179.0
0.29
0.19
Insect Screen (default)
Al
Window
N Wall (Front -0)
2.3
10.0
1
23.0
0.29
0.19
Insect Screen (default)
D29
Window
N Wall (Front -0)
12.0
12.0
1
144.0
0.34
0.19
Insect Screen (default)
S2
Window
N Wall (Front -0)
12.0
1.7
1
20.4
0.29
0.19
Insect Screen (default)
P1
Window
N Wall (Front -0)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
P2
Window
N Wall (Front -0)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
P12
Window
N Wall (Front -0)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
L4
Window
25d Wall 2 (- specify -25)
-
-
1
4.0
0.29
0.19
Insect Screen (default)
K4
Window
25d Wall 2 (- specify -25)
8.0
8.0
1
64.0
0.29
0.19
Insect Screen (default)
K6
Window
25d Wall 2 (- specify -25)
8.0
4.6
0.978
36.0
0.29
0.19
Insect Screen (default)
P11
Window
25d Wall 2 (- specify -25)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
C2
Window
50d Wall (- specify -50)
-
-
1
1 68.0
0.29
0.19
Insect Screen (default)
C3
Window
50d Wall (- specify -50)
-
-
1
1 68.0
0.29
0.19
Insect Screen (default)
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE qPOD
Project Name: Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1 B-PAR-Corner.xml
CFORF-01
Page 7 of 17
C4
Window
50d Wall (- specify -50)
-
-
1
68.0
0.29
0.19
Insect Screen (default)
N1
Window
E Wall (Left -90)
5.0
5.5
1
27.5
0.29
0.19
Insect Screen (default)
D19
Window
E Wall (Left -90)
5.0
10.0
1
50.0
0.34
0.19
Insect Screen (default)
M1
Window
E Wall (Left -90)
-
-
1
22.0
0.29
0.19
Insect Screen (default)
P10
Window
E Wall (Left -90)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
L3
Window
115d Wall 2 (-specify -115)
-
-
1
60.0
0.29
0.19
Insect Screen (default)
D17
Window
115d Wall 2 (- specify -115)
3.0
10.0
1
30.0
0.34
0.21
Insect Screen (default)
K3
Window
115d Wall 2 (- specify -115)
6.3
8.0
1
50.4
0.29
0.19
Insect Screen (default)
K5
Window
115d Wall 2 (- specify -115)
6.3
4.6
1.001
29.0
0.29
0.19
Insect Screen (default)
D16
Window
115d Wall 2 (- specify -115)
9.3
10.0
1
93.0
0.34
0.19
Insect Screen (default)
K2
Window
115d Wall 2 (- specify -115)
7.7
4.9
0.999
37.7
0.29
0.19
Insect Screen (default)
P9
Window
115d Wall 2 (- specify -115)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
P8
Window
115d Wall 2 (- specify -115)
--
-
1
5.7
0.29
0.19
Insect Screen (default)
P6
Window
S Wall (Back -180)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
P7
Window
S Wall (Back -180)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
D15
Window
205d Wall 2-(�specify f 205) c16.5 ,74 10.0
r 1
165.0
0.34
0.19
Insect Screen (default)
K1
Window
6205d Will 2 (- specify i 205)
1 11-,! 16.5
ti: ,-, 4.8
r 1)J `"'79.2
0.29
0.19
Insect Screen (default)
Window
Window
205d Wall,-2_(=,s6ecify'-,205)'- I U U 5.8
4?0
1 11.034 " [ 24.0
0.29
0.19
Insect Screen (default)
D12
Window
N265d Wall -2-(- s eci "205
22Y0
` 10.0 1
'"'220.0
0.34
0.19
Insect Screen default
J1
Window
205d Wall 2 (- specify -205)
--
-
1
102.0
0.29
0.19
Insect Screen (default)
11
Window
205d Wall 2 (- specify -205)
10.0
10.0
1
100.0
0.34
0.19
Insect Screen (default)
C6
Window
230d Wall (- specify -230)
-
-
1
68.0
0.29
0.19
Insect Screen (default)
D05
Window
230d Wall (- specify -230)
-
-
1
33.0
0.34
0.21
Insect Screen (default)
C5
Window
230d Wall (- specify -230)
-
-
1
68.0
0.29
0.19
Insect Screen (default)
D28
Window
W Wall (Right -270)
12.0
12.0
1
144.0
0.34
0.19
Insect Screen (default)
S1
Window
W Wall (Right -270)
12.0
1.7
1
20.4
0.29
0.19
Insect Screen (default)
P3
Window
W Wall (Right -270)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
P4
Window-
W Wall (Right -270)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
P5
Window
W Wall (Right -270)
-
-
1
5.7
0.29
0.19
Insect Screen (default)
R1
Window
295 Wall (- specify -295)
-
-
1
18.0
0.29
0.19
Insect Screen (default)
131
Window
340d Wall (- specify -340)
-
-
1
13.5
0.29
0.19
Insect Screen (default)
B2
Window
340d Wall (- specify -340)
--
-
1
13.5
0.29
0.19
Insect Screen (default)
Skylight 4
Skylight
Roof.2 (Right -270)
1
4.0
0.15
0.10
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD
Project Name: Filler/Sandy Inv Calculation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1 B-PAR-Corner.xml
C*RF-01 -
Page 8 of 17
Skylight 5
Skylight
Roof 2 (Right -270)
1
4.0
0.15
0.10
Skylight 6
Skylight
Roof 2 (Right -270)
1
12.6
0.15
'0.10
Skylight 7
Skylight
Roof 2 (Right -270)
1
4.0
0.15
0.10
F1
Window
230d Wall 2 (- specify -230)
4.0
10.0
1
40.0
0.29
0.19
Insect Screen (default)
D06
Window
295d Wall 2 (- specify -295)
9.0
10.0
1
90.0
0.34
0.21
1 Insect Screen (default)
d02
Window
25d Wall 3 (- specify -25)
4.0
10.0
2
80.0
0.34
0.19
Insect Screen (default)
E1
Window
25d Wall 3 (- specify -25)
-
-
1
40.0
0.29
0.19
Insect Screen (default)
D1
Window
115d Wall 3 (- specify -115)
-
-
1
58.5
0.29
0.19
Insect Screen (default)
D2
Window
230d Wall 3 (- specify -230)
-
-
1
18.0
0.29
0.19
Insect Screen (default)
D03
Window
295d Wall 3 (- specify -295)
8.0
10.0
1
80.0
0.34
0.19
Insect Screen (default)
E2
Window
295d Wall 3 (- specify -295)
-
-
1
8.0
0.29
0.19
Insect Screen (default)
E2 2
Window
295d Wall 3 (- specify -295)
-
-
1
16.0
0.29
0.19
Insect Screen (default)
D04
Window
320d Wall (- specify -320)
8.0
10.0
1
80.0
0.34
0.21
Insect Screen (default)
U7
Window
10d Wall (- specify -10)
5.0
10.0
1
50.0
0.29
0.19
Insect Screen (default)
U5
Window
1 O Wall (- specify -10)
-
-
1
27.0
0.29
0.19
Insect Screen (default)
U2
Window
1 Od Wall -(=specify s10) r;=7 r "Nh c"4 4- -
1
12.0
0.29
0.19
Insect Screen (default)
W4
Window
60d Wall (- spec-ifyOj( Ir`
2.0
3.0
11
!"-6.0
0.29
0.19
Insect Screen (default)
W2
Window
"�N 60d Will: (= specify:-, 0)N�;� L,- i U �1
3.0
1-0.0
�YY
j S,) 11,1 ` L30 0
0.29
0.19
Insect Screen (default)
U1
Window
-,�l'OOd WaIL(-specify-Lf00) 4;
1�
10.0
0.29
0.19
Insect Screen (default)
T2
Window
155d Wall (- specify -155)
6.0
10.0
1
60.0
0.34
0.21
Insect Screen (default)
D60
Window
155d Wall (- specify -155)
6.0
10.0
1
60.0
1.19
0.59
Insect Screen (default)
T1
Window
155d Wall (- specify -155)
6.0
10.0
1
60.0
0.29
0.19
Insect Screen (default)
Y4
Window
155d Wall (- specify -155)
-
-
1
23.2
0.29
0.19
Insect Screen (default)
T6
Window
170d Wall (- specify -170)
5.5
10.0
1
55.0
0.29
0.19
Insect Screen (default)
T5
Window
170d Wall (- specify -170)
5.5
10.0
1
55.0
0.29
0.19
Insect Screen (default)
T4
Window
170d Wall (- specify -170)
5.6
10.0
1
56.0
0.29
0.19
Insect Screen (default)
T3
Window
170d Wall (- specify --170)
5.5
10.0
1
55.0
0.29
0.19
Insect Screen (default)
D68
Window
S Wall 2 (Back -180)
12.3
10.0
1
123.0
0.34
0.19
Insect Screen (default)
Y3
Window
S Wall 2 (Back -180)
11.3
3.0
1
33.9
0.29
0.19
Insect Screen (default)
U4
Window
190d Wall 2 (- specify -190)
-
-
1
12.0
0.29
0.19
Insect Screen (default)
V3
Window
240d Wall (- specify -240)
3.0
10.0
1
30.0
0.29
0.19
Insect Screen (default)
D67
Window
W Wall 2 (Right -270)
--
-
1
48.0
0.34
0.19
Insect Screen (default)
Y2
Window
W Wall 2 (Right -270)
4.3
3.0
0.977 1
12.6 1
0.29
0.19
Insect Screen (default)
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Filler/Sandy Inv Ca cu'ation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
C*RF-01 -
Page 9 of 17
Y1
Window
W Wall 2 (Right -270)
11.5
12.3
1
141.5
0.29
0.19
Insect Screen (default)
W5
Window
W Wall 2 (Right -270)
2.0
4.0
1
8.0
0.29
0.19
Insect Screen (default)
D64
Window
280d Wall (- specify -280)
3.5
10.0
1
35.0
0.34
0.21
Insect Screen (default)
U6
Window
280d Wall (- specify --280)
2.3
10.0
1
23.0
0.29
0.19
Insect Screen (default)
U3
Window
280d Wall (- specify -280)
-
-
1
53.6
0.29
0.19
Insect Screen (default)
D66
Window
330d Wall (- specify -330)
7.0
10.0
1
70.0
0.34
0.19
Insect Screen (default)
W3
Window
330d Wall (- specify -330)
2.2
10.0
1
22.0
0.29
0.19
Insect Screen (default)
W1
Window
330d Wall (- specify -330)
3.8
10.0
1
38.0
0.29
0.19
Insect Screen (default)
V4
Window
330d Wall (- specify -330)
3.8
10.0
1
38.0
0.29
0.19
Insect Screen (default)
V2
Window
330d Wall (- specify -330)
2.2
10.0
1
22.0
0.29
0.19
Insect Screen (default)
D65
Window
330d Wall (- specify -330)
7.0
10.0
1
70.0
0.34
0.19
Insect Screen (default)
V1
Window
330d Wall (- specify -330)
-
--
1
6.0
0.29
0.19
Insect Screen (default)
C(*a"44�,iL4""4ERTS, nc.
HEIRS PROVI DER
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI10E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I
Project Name: Filler/Sandy Inv CkOD ation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1B-PAR-Corner.xml
CF*RF-01
Page 10 of 17
OVERHANGS AND FINS
01
02
03
04
05
06ZO
08 09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.op
Up DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
H8
15
0.1
15
15
0
0 0
0
0
0
0
0
D10
15
0.1
15
15
0
0
0 0
0
0
0
0
0
H7
18
0.1
18
18
0
0
0 0
0
0
0
0
0
D09
12
0.1
12
12
0
0
0 0
0
0
0
0
0
H2
15
0.1
15
15
0
0
0 0
0
0
0
0
0
H4
15
0.1
15
15
0
0
0 0
0
0
0
0
0
G2
8
0.1
8
8
0
0
0 0
0
0
0
0
0
H1
15
0.1
15
15
0
0
0 0
0
0
0
0
0
H3
15
0.1
15
15
0
0
0 0
0
0
0
0
0
C1
6
0.1
6
6
0
0
0 0
0
0
0
0
0
A2
12
0.1
M,11 2
N 1,20ak
U0.00,p%` - 0�,M
00 0
0
0
0
0
0
D01
12
'40.1
1231
f #12
I Lm QLAO
A 0%*,
of I'%
0
0
0
0
0
A3
12
�L_It0.1
lh 2U
1 `11
L0J I
10"
0f I t b" *
0
0
0
0
0
Al
12
'"%0�1
X12
M12C
r0 0
0-0 %'j arf
0�-N I= 0rn�
0
0
0
0
0
D29
18
el
"18 "
° "18'
" 0
"`6
0� .4.- Cr
0
0
0
0
0
S2
18
0.1
18
18
0
0
0 0
0
0
0
0
0
K4
6
0.1
6
6
0
0
0 0
0
0
0
0
0
K6
6
0.1
6
6
0
0
0 0
0
0
0
0
0
N1
18
0.1
18
18
0
0
0 0
0
0
0
0
0
D19
10
0.1
10
10
0
0
0 0
0
0
0
0
0
D17
6
0.1
6
6
0
0
0 0
0
0
0
0
0
K3
6
0.1
6
6
0
0
0 0
0
0
0
0
0
K5
6
0.1
6
6
0
0
0 0
0
0
0
0
0
D16
12
0.1
12
12
0
0
0 0
0
0
0
0
0
K2
12
0.1
12
12
0
0
0 0
0
0
0
0
0
D15
15
0.1
15
15
0
0
0 0
0.
0
0
0
0
K1
15
0.1
15
15
0
0
0 0
0
0
0
0
0
Window
15
0.1
15
15
0
0
0 0
0
0
0
0
0
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JPOD
Project Name: Filler/Sandy Inv culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1 B-PAR-Corner.xml
C*RF-01 -
Page 11 of 17
D12
30
0.1
30
30 0
0
0
0
0
0
0
0
0
11
18
0.1
18
18 0
0
0
0
0
0
0
0
0
D28
18
0.1
18
18 0
0
0
0
0
0
0
0
0
S1
18
0.1
18
18 0
0
0
0
0
0
0
0
0
F1
8
0.1
8
8 0
0
0
0
0
0
0
0
0
D06
10
0.1
10
10 0
0
0
0
0
0
0
0
0
d02
8
0.1
8
8 0
0
0
0
0
0
0
0
0
D03
15
0.1
15
15 0
0
0
0
0
0
0
0
0
D04
8
0.1
8
8 0
0
0
0
0
0
0
0
0
U7
4
0.1
4
4 0
0
0
0
0
0
0
0
0
W4
4
0.1
4
4 0
0
0
0
0
0
0
0
0
' W2
8
0.1
8
8 0
0
0
0
0
0
0
0
0
T2
10
0.1
10
10 0
0
0
0
0
0
0
0
0
D60
10
0.1
10
10 0
0
0
0
0
0
0
0
0
T1
10
0.1
10
10 0
0
0
0
0
0
0
0
0
T6
8
0.1
�8
n 8l*;� 71=0F'; 0
on
0
0
0
0
0
0
T5
8
r�0.1
8
1118 ir�'=0
11 0
oil
IG N 0r
0
0
0
0
0
T4
8
"�_0.1
i 8+, ..
U `8 0,}
U 0 J 17
0IJ
U U 6,�
0
0
0
0
0
T3
8
�1
'H8 F
811; ,P0,
ir0 1
0'" OR
0
0
0
0
0
D68
18
0.1
18
18 0
0
0
0
0
0
0
0
0
Y3
18
0.1
18
18 0
0
0
0
0
0
0
0
0
V3
8
0.1
8
8 0
0
0
0
0
0
0
0
0
Y2
10
0.1
10
10 0
0
0
0
0
0
0
0
0
Y1
10
0.1
10
10 0-
0
0
0
0
0
0
0
0
W5
2
0.1
2
2 0
0
0
0
0
0
0
0
0
D64
10
0.1
10
10 0
0
0
0
0
0
0
0
0
U6
8
0.1
8
8 0
0
0
0
0
10
0
0
0
D66
4
0.1
4
4 0
0
0
0
0
0
0
0
0
W3
4
0.1
4
4 0
0
0
0
0
0
0
0
0
Wt
12
0.1
12
12 0
0
0
0
0
0
0
0
0
V4
12
0.1
12
12 0
0
0
0
0
0
0
0
0
V2
4
0.1
4
4 0
0
0
0
0
0
0
0
0
D65
4
0.1
4
4 0
0
0
0
0
0
0
0
0
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD
Project
'PE
Filler/Sandy Inv Itculation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: Madison lot 1 B-PAR-Corner.xml
C*RF-01 -
Page 12 of 17
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
02
03
04
05
Total Cavity
Winter Design
Name
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Master Suite
1459
141
None
0.8
No
• Cavity/ Frame: no insul. /2x4 Top Chrd
Living/Kit/Din/Office
3209
182
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck. Wood Siding/sheathing/decking
Attic RoofMaster Suite
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Guest 2
742
107
None
0.8
No
• Inside Finish: Gypsum Board
Casita
Ceilings (below
346
None
0.8
No
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/ Frame: R-38 / 2x4
• Roof Deck. Wood Siding/sheathing/decking
R-38 Roof Atticl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.041
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/ Frame: R-21 /2x6
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
Attic RoofLiving/KIt/Dln/Office
Attic Roofs
W6d Framed Ceiing t
S r•�
2x4 Top Chord£of Roof Truss '@ 24
in O.0 � '
none
0 644
Cavdy/Frame: no insul. /2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
t
Cavity/Frame: no insul. /2x4 Top Chrd
Attic RoofGuest 1
Attic Roofs
Wood, Ceiling ^
2z4)Top'.Chord ofRoof Truss -@'24
in. O.C.
none
0:644
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofGuest 2
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing., Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofCasita
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing. Light Roof (Asphak Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Covered Slab
Master Suite
1459
141
None
0.8
No
Covered Slab 2
Living/Kit/Din/Office
3209
182
None
0.8
No
Covered Slab 3
Guest 1
429
31
None
0.8
No
Covered Slab 4
Guest 2
742
107
None
0.8
No
Covered Slab 5
Casita
2298
346
None
0.8
No
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE kOD
Project Name: Filler/Sandy Inv Calculation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 7314.3
CF*RF-01
Page 13 of 17
WATER HEATING SYSTEMS
01
02
03
04
05
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/2
DHW
Pipe Insulation, All Lines
DHW Heater 1
2
.0%
DHW Sys 3 - 1/1
DHW
Pipe Insulation, All Lines
DHW Heater 3
1 _
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
^� ,4 Tank Type
Tank Volume
�(gaq
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas _
Large Stoiag`e
�t 100
0.78 '9
85000 Btu/hr
0
0.03
DHW Heater 3
Natural Gas �
Large Sto age
fild(A I
X0.78
85000-Btu/hr
0
0.03
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/2
—
—
—
—
—
—
DHW Sys 3 - 1/1
—
—
—
—
—
—
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE . OD
Project
'PE
Filler/Sandy Inv Ca culation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
CF�RF-01 -
Page 4 of 17
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 11
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Cooling Component 1
System
13.1
16.7
Zonally Controlled
Single Speed
HVAC 2, 3, 4 & 52
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC 6 & 73
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC - HEATING UNIT TYPES
01
02'�� *�
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
97.2 AFUE
Heating Component 2
CntdFurnace - Fuel -fired central furnace
97.2 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
97.4 AFUE
/� it fC If a mil 14 It " It ._
HVAC - COOLING UNIT TYPES H If It R
01
02'�� *�
r. 03 " " *4 '404 %=O'
€ '05
06
07
Name
Verified Airflow
Efficiency tj V I
t: tt
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 2
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 3
SplitAirCond
13.5
18
Zonally Controlled
Single Speed
Cooling Component
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
150
Required
Required
Required
Cooling Component 2 -hers -cool
Required
150
Required
Required
Required
Cooling Component 3 -hers -cool
Required
150
Required
Required
Required
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version'- CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 4kOD
Project Name: Filler/Sandy Inv Cation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
CF*RF-01 -
Page 15 of 17
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
Lowl-lCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
1 -hers -dist
Air Distribution System 2
Lowl-lCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
2 -hers -dist
Air Distribution System 3
Lowl-lCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
3 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct Buried
Design Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0
Required
Not Required Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required
6.0
Required
Not Required Not RequiredNot
Required
—
Air Distribution System 3 -hers -dist
Required
6.01
__Required._
s Noott Required Not Required
Not Required
—
If 0;;__. i! A£ 21 YF lF 3i 1V lF d
HVAC -FAN SYSTEMS
>� [ .� _ _ i ,
It �. I
02
01
i
a d►^ �? +�^r
rix *—,* *_.03
04
Name
`
a"' Type `� i a
° '� *Fan Power(Watt /CFM)
HERS Verification
HVAC Fan 1
Required
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
HVAC Fan 3 -hers -fan
Required
0.58
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-08252015-744 Report Generated at: 2015-08-28 16:52:00
CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D
Project ame: Filler/Sandy Inv Clacu'O
ation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1B-PAR-Corner.xml
C*RF-01
Page 16 of 17
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
219.74
0.25
Default
0
Required
"t1h1C'RTS, I nc
HERS PROVIDER
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-08-28 16:52:00
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD
Project Name: Filler/Sandy Inv ation Date/Time: 16:49, Fri, Aug 28, 2015
Calculation Description: Title 24 Analysis Input File Name: Madison lot 1 B-PAR-Corner.xml
CF.ORF-01
Page 7 of 17
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
7&W15C'4z
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-08-28 17:03:27
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to -the enforcement,agency,for approval,with;this,building permit application.
Responsible Designer Name:R
r
esponsible Designer Sig a tures
%urv.�caZ�i
C
Tim ScottL
!
? �f
Company:
Date Signed: A �
2015 08 2817:0�3:27'i
Scott Design and Title 24, Inc.
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N6307872A-000000000-0000 Registration Date/Time: 2015-08-28 17:03:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-08-28 16:52:00
•
r1
L - -J
C
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler & Sandy Investments, LLC
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/28/2015
Project Address
Lot 18, The Madison clubLa Quinta India
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,974
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavi(ft)
Area
Special Features Status
Roof Wood Framed Attic
R38
9,934 Cool Roof
New
Wall Wood Framed
R 21
5,602
New
Slab Unheated Slab -on -Grade
- no insulation
8,137 Perim = 807'
New
Demising Wood Framed
R 13
2,445
New
FENESTRATION
Orientation Area f 2
I Total Area: 4.774 Glazing Percentage: 47.9
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor: 0.33
Exterior Shades Status
Skylight 4.0
0.150
0.10 none
none
None New
Skylight 4.0
0.150
0.10 none
none
None New
Skylight 7.1
0.150
0.10 none
none
None New
Front (N) 30.4
0.290
0.19 15.0
none
Bug Screen New
Front (N) 70.0
0.340
0.19 15.0
none
Bug Screen New
Rear (SVIO 68.0
0.290
0.19 18.0
none
Bug Screen New
Rear (SM 70.0
0.340
0.19 12.0
none
Bug Screen New
Rear (SVIO 176.0
0.290
0.19 15.0
none
Bug Screen New
Rear (SM 8.0
0.290
0.19 8.0
none
Bug Screen New
Right (NIM 78.0
0.290
0.19 15.0
none
Bug Screen New
Right (NiM 144.0
0.290
0.19 none
none
Bug Screen New
Skylight 4.0
0.150
0.10 none
none
None New
Skylight 4.0
0.150
0.10 none
none
None New
Skylight 12.6
0.150
0.10 none
none
None New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
97% AFUE
Split Air Conditioner 16.7 SEER
Setback
New
4 Central Furnace
97% AFUE
Split Air Conditioner 16.7 SEER
Setback
New
2 Central Fumace
97% AFUE
Split Air Conditioner 18.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
HVAC 1 Ducted
Ducted
Conditioned
8.0
New
HVAC 2, 3,4 & 5 Ducted
Ducted
Conditioned
8.0
New
HVAC 6 & 7 Ducted
Ducted
Conditioned
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
2 large Storage Gas
100
0.78
All Pipes Ins
New
1 Large Storage Gas
100
0.78
All Pipes Ins
New
EnergyPro 6.7 by EnerqySoft User Number: 6712
Run Code: 2015-08-28716:53.47
/D:
Page 20 of 54
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler & Sandy Investments, LLC
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/28/2015
Project Address
Lot 18, The Madison clubLa Quinta India
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,974
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
FENESTRATION
Orientation Area(ft)
I Total Area: 4,774 Glazing Percentage: 47.9%1New/Altered
U -Fac SHGC Overhang Sidefins
Average U -Factor: 0.33
Exterior Shades Status
Skylight 4.0
0.150
0.10 none
none
None New
Front (N) 58.0
0.290
0.19 6.0
none
Bug Screen New
Front (N) 252.0
0.290
0.19 12.0
none
Bug Screen New
Front (N) 60.0
1.190
0.59 12.0
none
Bug Screen New
Front (N) 144.0
0.340
0.19 18.0
none
Bug Screen New
Front (N) 20.4
0.290
0.19 18.0
none
Bug Screen New
Front (N) 17.1
0.290
0.19 none
none
Bug Screen New
Front (NE) 49.7
0.290
0.19 none
none
Bug Screen New
Front (NE) 100.0
0.290
0.19 6.0
none
Bug Screen New
Left (NE) 204.0
0.290
0.19 none
none
Bug Screen New
Left (E) 27.5
0.290
0.19 18.0
none
Bug Screen New
Left (E) 50.0
0.340
0.19 10.0
none
Bug Screen New
Left (E) 27.7
0.290
0.19 none
none
Bug Screen New
Left (SE) 129.9
0.290
0.19 none
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnemyPro6.7 by EnemySoft User Number: 6712
Run Code: 2015-08-28T16:53:47
ID:
Page 21 of 54
•
C
n
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler & Sandy Investments, LLC
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/28/2015
Project Address
Lot 18, The Madison clubLa Quinta India
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,974
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavi(ft)
Area
Special Features Status
FENESTRATION
Orientation Area(ft)
I Total Area: 4,774 Glazin Percentage: 47.9 - New/Altered Average U -Factor: 0.33
U -Fac SHGC Overhang Sidefins Exterior Shades Status
Left (SE) 30.0
0.340
0.21 6.0
none Bug Screen New
Left (SE) 79.4
0.290
0.19 6.0
none Bug Screen New
Left (SE) 93.0
0.340
0.19 12.0
none Bug Screen New
Left (SE) 37.7
0.290
0.19 12.0
none Bug Screen New
Rear (S) 11.4
0.290
0.19 none
none Bug Screen New
Rear (SVV) 165.0
0.340
0.19 15.0
none Bug Screen New
Rear (SVtq 220.0
0.340
0.19 30.0
none Bug Screen New
Rear (SVIq 102.0
0.290
0.19 30.0
none Bug Screen New
Rear (SVV) 100.0
0.340
0.19 18.0
none Bug Screen New
Right (SVt9 154.0
0.290
0.19 none
none Bug Screen
New
Right (SVI9 33.0
0.340
0.21 none
none Bug Screen
New
Right (Kq 144.0
0.340
0.19 18.0
none Bug Screen New
Right (W) 20.4
0.290
0.19 18.0
none Bug Screen New
Right (WJ 17.1
0.290
0.19 none
none Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R -Value Status
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnerqvPro6.7 by EnerqySoft User Number: 6712
Run Code: 2015-08-28T16:53:47 ID:
Page 22 of 54
0
L'
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler & Sandy Investments, LLC
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/28/2015
Project Address
Lot 18, The Madison clubLa Quinta India
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,974
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavi(ft)
Area
Special Features Status
FENESTRATION
Orientation Area(ft)
I Total Area: 4774 Glazing Percentage: 47.9%1New/Altered
U -Fac SHGC Overhang Sidefins
Average U -Factor: 0.33
Exterior Shades Status
Front (N) 27.0
0.290
0.19 none
none
Bug Screen New
Right (SM 40.0
0.290
0.19 8.0
none
Bug Screen New
Right (NKK 90.0
0.340
0.21 10.0
none
Bug Screen New
Front (NE) 80.0
0.340
0.19 8.0
none
Bug Screen New
Right (NM 80.0
0.340
0.19 15.0
none
Bug Screen New
Front (NKK 80.0
0.340
0.21 8.0
none
Bug Screen New
Front (N) 50.0
0.290
0.19 4.0
none
Bug Screen New
Front (N) 39.0
0.290
0.19 none
none
Bug Screen New
Left (NE) 6.0
0.290
0.19 4.0
none
Bug Screen New
Left (NE) 30.0
0.290
0.19 8.0
none
Bug Screen New
Left (E) 10.0
0.290
0.19 none
none
Bug Screen New
Rear (SE) 60.0
0.340
0.21 10.0
none
Bug Screen New
Rear (SE) 60.0
1.190
0.59 10.0
none
Bug Screen New
Rear (SE) 60.0
0.290
0.19 10.0
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
Ene Pro6.7 by EnerqySoft User Number: 6712
RunCode: 2015-08-28716:53:47
ID:
Pa a 23 of 54
C
1�
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler & Sandy Investments, LLC
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/28/2015
Project Address
Lot 18, The Madison clubLa Quinta India
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,974
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavi
Area
(ft) Special Features Status
FENESTRATION
Orientation Area ft2
I Total Area: 4774 Glazing Percentage: 47.9 yo New/Altered Average U -Factor: 0.33
U -Fac SHGC Overhang Sidefins Exterior Shades Status
Rear (SE) 23.2
0.290
0.19 none
none Bug Screen New
Rear (S) 221.0
0.290
0.19 8.0
none Bug Screen New
Rear (S) 123.0
0.340
0.19 18.0
none Bug Screen New
Rear (S) 33.9
0.290
0.19 18.0
none Bug Screen New
Rear (S) 12.0
0.290
0.19 none
none Bug Screen New
Right (S1M 30.0
0.290
0.19 8.0
none Bug Screen New
Right (Vtq 48.0
0.340
0.19 10.0
none Bug Screen New
Right (Vtq 154.1
0.290
0.19 10.0
none Bug Screen New
Right (VV) 8.0
0.290
0.19 2.0
none Bug Screen
New
Right (Ko 35.0
0.340
0.21 10.0
none Bug Screen
New
Right (Kq 23.0
0.290
0.19 8.0
none Bug Screen
New
Right (1" 53.6
0.290
0.19 none
none Bug Screen New
Front (NVt9 140.0
0.340
0.19 4.0
none Bug Screen New
Front (NVtq 44.0
0.290
0.19 4.0
none Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R -Value Status
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro6.7 by EnemySoft User Number: 6712
Run Code: 2015-08-28716:53:47 ID:
Page 24 of 54
•
1�
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler & Sandy Investments, LLC
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/28/2015
Project Address
Lot 1B, The Madison clubLa Quinta India
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,974
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
FENESTRATION I Total Area: 4,774 Glazing Percentage: 47.9 New/Altered Average U -Factor: 0.33
Orientation Area ft U -Fac SHGC Overhang Sidefins Exterior Shades Status
Front (NlAq 76.0 0.290
0.19 12.0 none Bug Screen New
Front (NKK 6.0 0.290
0.19 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro6.7 by EnerqvSoft User Number: 6712
RunCode: 2015-08-28716:53:47 ID:
Page 25 of 54
1. 2013' Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of § 10-11l(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF 1 R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ I50.0(e)I C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)1A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013- Low -Rise Residential Mandatory Measures Summary
§150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ I50.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10: Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13: space conditioning system must also demonstrate airflow_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013. Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§I50.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I50.0(k)IC:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ I50.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ I50.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k) I F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to $110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
1�
2013 Low -Rise Residential Mandatory Measures Summary
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, §130.0, §130.2, §130.4, §140.7 and 141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, $140.7 and §141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in §110.9, § 130.0, § 130.2, § 130.4 § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I50.0(k)I2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ I 50.0(k) I 2B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§I 10.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of $110.10 b through § 110.10(e).
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§I 10.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
0
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
I.Filler & Sandy Investments, LLC
Date
8/28/2015
System Name
HVAC 1
Floor Area
1,459
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,183
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 243
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem
78,000
20,877
1,647 546
18,054
Total Output Btuh
78,000
0
Output Btuhls ft
53.5
0
0
Cooling System
0
0
Output perSystem
58,000
9,316
3,058 243
11,904
Total Output Btuh
58,000
0
4,705
0
Total Output Tons
4.8
0
0
Total Output Btuh/s ft
39.8
Total Output s ft/Ton
301.9
1 30,193
29,958
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ANB160-59MN7A80-20 44,597 7,943
78,000
Airflow cfmis ft
1.37
Airflow cfmlTon
413.8
Outside Air %
12.2 %
Total Adjusted System Output 44,597 7,943 78,000
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.17
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
243 cfm
72 OF
66 OF 103 OF 103 OF
Heating Coil Supply Fan
2,000 cfm 103 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/66°F 80/66°F 59/58°F
Outside Air 0
243 cfm Supply Fan Cooling Coil 59 / 58 OF
2,000 cfm
53.4% I'ROOM
76/64°F 76/64°F
EnergyPro 6.7 by EnergySoff
User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Page 30 of 54
SYSTEM HEATING AND COOLING LOADS SUMMARY
e
Fandy Investments, LLC
Date
8/28/2015
System Name
HVAC 2, 3, 4 & 5
Floor Area
6,217
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 4
COIL
CFM
Total Room Loads 5,024
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 1,036
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 78,000
87,192
7,020 2,592
84,654
Total Output Btuh 312,000
0
Output Btuh/s ft 50.2
0
0
Cooling System
0
0
Output perSystem 58,000
39,697
12,471 1,036
50,725
Total Output Btuh 232,000
0
0
126,890 19,491
0
Total Output Tons 19.3
0
Total Output Btuh/s ft 37.3
Total Output s ft/Ton 321.6
135,378
Air System
CFM perSystem 2,000
HVAC EQUIPMENT SELECTION
Airflow cfm 8,000
Carrier 24ANB160-59MN7A80-20 178,541 32,499 312,000
Total Adjusted System Output 178,541 32,499 312,000
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Airflow cfm/s ft 1.29
Airflow cfm/Ton 413.8
Outside Air % 13.0%
Outside Air cfm/s ft 0.17
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 66 OF 103 OF 103 OF
MOM
10 00.
Outside Air Ar Pi ' �-I d
1,036 cfm Heating Coil Supply Fan
8,000 cfm 103 o F
ROOM
72 OF 72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81/66°F 81/66°F 60/59°F
Outside Air Ar V
1,036 cfm Supply Fan Cooling Coil 60 / 59 OF
8,000 cfm
53.9% [ROOM
76/64°F 76/64°F
EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Page 31 of 54
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
filler & Sandy Investments, LLC
Date
8/28/2015
System Name
HVAC 6 & 7
Floor Area
2,298
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 2,210
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 383
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 78,000
40,718
2,595 1,101
47,236
Total Output Btuh 156,000
0
Output Btuhls ft 67.9
0
0
Cooling System
0
0
Output per System 47,200
14,673
5,363 383
18,749
Total Output Btuh 94,400
0
0
55,391
7,958
0
Total Output Tons 7.9
0
Total Output Btuhls ft 41.1
Total Output s ft/Ton 292.1
65,985
Air System
CFM perSstem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
3,200
Carrier 24ANB148-59MN7A080-20
73,642
11,315
156,000
Airflow cfm/s ft
1.39
Airflow cfm/Ton
406.8
Outside Air %
12.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
73,642
11,315
Aug 3 M1
156,000
F Jan 1 AM
Outside Air cfm/s ft 0.17
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
383 cfm .
72 OF
66 OF 112 OF 112 OF
► ���
Heating Coil Supply Fan
3,200 cfm
112 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78°F 80/66°F 80/66°F 59/58°F
Outside Air
383 cfm Supply Fan Cooling Coil
3,200 cfm
76/64°F
59 / 58 OF
51.9% ROOM
76/64°F
EnergyPro 6.7 by EnergySoR
User Number: 6712 Run Code: 2015-08-28716:53:47
ID:
Page 32 of 54
A&
•
ROOM LOAD SUMMARY
Project Name Date
Filler & Sandy Investments, LLC 8/28/2015
System Name Floor Area
HVAC 1 1,459
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name. Room Name Mult. CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible
Master Suite I Master Ste Zone I 1 1 1,1831 20,8771 1,647 1,1831 20,8771 1,647 5461 54
PAGE TOTAL
TOTAL '
1,183 20,8771
1,6471
546
18,054
1,1831 20,8771
1,6471
546
18.054
Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnemySoft User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Page 33 of 54
•
•
ROOM LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
Date
8/28/2015
System Name
HVAC 2, 3, 4 & 5
Floor Area
6,217
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM
Sensible Latent
CFM Sensible
Livingh<&Din/Office Living Zone
1 4,011 69,615 5,698
4,011
69,615
5,698
2,015 65,814
Guest 1 Guest 1
1 282 4,899 484
282
4,899
484
144 4,709
Guest 2 Guest 2
1 731 12,679 838
731
12,679
838
433 14,130
' Total includes ventilation load for zonal systems.
PAGE TOTAL
TOTAL 1
5,024
5,024
87,192
87,192
7,020
7,020
2,592 84,654
2,592 84,654
EnergyPro 6.7 by EnergySoft User Number: 6712
Run Code: 2015-08-28716:53:47
/D:
Page 34 of 54
r�
01
•
ROOM LOAD SUMMARY
Project Name Date
Filler & Sandy Investments, LLC 8/28/2015
System Name Floor Area
HVAC 6 & 7 Z298
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Casita Casita 1 2210 40,718 2,595 2,210 40,718 2,595 1,1011 47,236
' Total includes
PAGE TOTAL
TOTAL*
2,2101
40,7181
2,5951
1,101
47,236
2,210
40,718
2,595
1,101
47,236
•
n
U
ROOM HEATING PEAK LOADS
Project Name
Filler & Sandy Investments, LLC
Date
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Ste Zone
Floor Area 1,459.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X 0.0260
X 0.1500
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
Btu/hr
R-38 Roof Attic
1,443.9
46
=
c
1,727
Skylight
15.1
46
104
R-21 Wall (W.21.2x6.16)
421.8
X
0.0690
46
c
c
c
1,339
530 Fixed
359.2
X
X
X
0.2900
46
4,792
3070 Door
140.0
0.3400
46
2,190
Slab -On -Grade
perim = 141.0
0.7300
46
_
4,735
'R-13 Wall
475.0
X
X
X
X
0.1020
0
_
o
=
=
0
X
X
=
=
X
X
=
=
X
X
=
X
X
=
X
=
X
=
=
=
=
X
X
X
X
X
X
=
=
=
=
X
X
X
X
=
=
=
Page Total
/60] X 46
AT
X
to another room
10.00 X 0.266
Ceiling Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,459 X
Area
14,886
= 3,168
TOTAL HOURLY HEAT LOSS FOR ROOM 18,054
EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-28716:53.47 /D: Page 36 of 54
•
•
•
ROOM HEATING PEAK LOADS
Project Name
Filler & Sandy Investments, LLC
Date
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living Zone
Floor Area 5,046.0 ft'
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
Btu/hr
= 6,006
= 170
= 6,097
= 17,876
= 3,284
= 14,326
= 985
c 6,112
_ 0
=
=
=
=
=
=
=
=
=
=
=
c
=
c
=
=
=
=
=
=
=
54,856
46 = 10,958
R-38 Roof Attic
5,021.4
X
X
X
0.0260
46
Skylight
24.6
0.1500
46
R-21 Wall (W.21.2x6.16)
1,921.0
0.0690
46
530 Fixed
1,340.0
X
X
X
X
0.2900
46
Custom Entry Door
60.0
1.1900
46
3070 Door
916.0
0.3400
46
3500 Door
63.0
0.3400
46
Slab -On -Grade
perim = 182.0
X
X
X
X
0.7300
46
'R-13 Wall
945.0
0.1020
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 5,046 X
Area
to another room
10.00 X 0.266
Ceiling Height ACH
Page Total
/60] X
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 65,814
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-28T16:53:47 /D: Page 37 of 54
/ 1
U
F-7
LJ
ROOM HEATING PEAK LOADS
Project Name
Filler & Sandy Investments, LLC
Date
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest 1
Floor Area 429.0 It'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
AT *F
X 46
X 46
X 46
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof Attic
429.0
0.0260
513
R-21 Wall (W.21.2x6.16)
89.0
0.0690
282
530 Fixed
40.0
0.2900
534
3033 Door
90.0
0.3400
X
46
1,408
Slab -On -Grade
perim = 31.0
0.7300
X
X
X
46
1,041
"R-13 Wall
455.0
0.1020
0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration: 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 429 X
Area
another room
10.00 X 0.266
Height ACH
Page Total
/60] X
AT
3,778
= 932
TOTAL HOURLY HEAT LOSS FOR ROOM 4,709
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Page 38 of 54
•
•
•
ROOM HEATING PEAK LOADS
Project Name
Date
Filler & Sandy Investments, LLC
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Guest 2
Time of Peak
Jan 1 AM
Floor Area
742.0 ft2
Outdoor Dry Bulb
Temperature
26 OF
Indoor Dry Bulb Temperature
72 OF,
Conduction
Area
U -Value
AT
°F
Btu/hr
R-38 Roof Attic
742.0
X
0.0260
X
46 =
887
R-21 Wall (W.21.2x6.16)
759.5
X
0.0690
X
46 =
2,411
3070 Door
160.0
X
0.3400
X
46 =
2,502
530 Fixed
140.5
X
0.2900
X
46 =
1,874
3033 Door
80.0
X
0.3400
X
46 _
1,251
Slab -On -Grade
Perim = 107.0
X
0.7300
X
46 =
3,593
"R-13 Wall
285.0
X
0.1020
X
0 _
0
X
X
=
X
X
=
X
X
X
X
o
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
-
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Items shown with an asterisk (') denote conduction through an interior surface
to another room
Page Total
12,519
Infiltration:[ 1.00 X 1.064 X 742 X
10.00
X 0.266
/60]
X 46
= 1,611
Schedule Air Sensible
Area
Ceiling Height
ACH
AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
14,130
EnergyPro 6.7 by EnergySoft User Number: 6712
Run Code: 2015-08-28716:53:47
/D:
Page 39 of 54
•
C
C
ROOM HEATING PEAK LOADS
Project Name
Filler & Sandy Investments, LLC
Date
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 2298.0 It2
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
0.0260 X
0.0690 X
0.2900 X
0.3400 X
1.1900 X
0.3400 X
0.7300 X
0.1020 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
another room
10.00 X 0.266
Height ACH
AT *F Btu/hr
46 = 2,748
46 = 6,507
46 _ 11,737
46 = 1,486
46 = 3,284
46 = 4,864
46 = 11,619
0 = 0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 42,245
/60] X 46 = 4,990
AT
R-38 Roof Attic
2,298.0
X
R-21 Wall (W.21.2x6.16)
2,050.2
X
530 Fixed
879.8
X
X
3500 Door
95.0
Custom Entry Door
60.0
X
X
X
X
3070 Door
311.0
Slab -On -Grade
perim = 346.0
'R-13 Wall
285.0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface to
X 2,298 X
Area Ceiling
TOTAL HOURLY HEAT LOSS FOR ROOM 47,236
EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-28716:53:47 /D: Page 40 of 54
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
Room Name Master Ste Zone Outdoor Dry Bulb Temperature
Floor Area 1,459.0 ft-- Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Rancie:
Oaaaue Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W 21.2x6.16)
R-21 Wall (W.21.2x6.16)
'R-13 Wall
Orientation
(VL9
(NE)
(N)
(StM
(NW)
8/28/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,443.9
0.0260
77.0
85.0
0.0690
32.7
55.6
0.0690
31.0
41.2
0.0690
45.8
240.0
0.0690
51.2
475.0
0.1020
0.0
0.0
16.2
70.0
16.2
68.0
15.2
0.0
33.2
70.0
16.2
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPnPQtrAtinn
Skylight
Skylight
Skylight
H8
D10
H7
D09
H2
H4
Orientation
(IM
(IM
(tM
(N)
(N)
(SM
(SM
(SlM
(SIM
Shaded Unshaded
112 OF
78 OF
34 OF
Btulhr
2,891
192
119
130
01
1 4,1781
Area
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+0.0
Area
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
8.1
4.0
31.9
0.0
8.1
4.0
31.9
0.0
8.1
7.1
31.9
0.0
15.2
30.4
15.2
0.0
16.2
70.0
16.2
68.0
15.2
0.0
33.2
70.0
16.2
0.0
34.2
48.8X
15.2+
0.0X
33.2=
24.0
15.2
33.2
Page Total
Btu/hr
127
127
226
462
1,134
1,034
1,134
742
365
Internal Gain Btulhr
Occupants 4.4 Occupants X 245 Btuh/occ. = 1,t
Equipment 1,459 Floor Area X 0.50 w/sqft =
Infiltration: 1.064 X 0.88 X 66.86 X 36 =
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20.8771
Latent Gain Btu/hr
Occupants 4 4 Occupants X 155 Btuh/occ. = 678
Infiltration: 4.771 X 0.88 X 66.86 X 0.00344 = 969
Air Sensible CFM ELA AW
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Page 41 of 54 1
i
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Filler & Sandy Investments, LLC
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Ste Zone
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,459.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btulhr
G2 (SIM 8.0 X 15.2 +
0.0 X 33.2 =
122
H1 (NM 34.0 X 15.2 +
18.0 X 37.4 =
1,190
H3 (NIM 26.0 X 15.2 +
0.0 X 37.4 =
395
G1 (NIM 0.0 X 15.2 +
102.0 X 37.4 =
3,814
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
5,521
Internal Gain
Btu/hr
Occupants 4 4 Occupants X 245
Btuh/occ. =
1,072
Equipment 1,459 Floor Area X 0.50
w/sgft
Infiltration: 1.064 X 0.88 X 66.86 X 36 =
2,264
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
20,877
Latent Gain
Btu/hr
Occupants 4 4 Occupants X 155
Btuh/occ. =
678
Infiltration: 4,771 x 0.88 x 66.86 x 0.00344 —
969
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
678
EneMyPro 6.7 by EnemySoft User Number- 6712 RunCode: 2015-08-28716:53:47 ID:
Page 42 of 54
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Zone Outdoor Dry Bulb Temperature
Floor Area 5,046.0 ft' Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranae:
Onanue Surfarps
R-38 Roof Affic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W..21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
Orientation
(►M
(N)
(NE)
(E)
(SE)
(S)
(S)
(SM
(S -K9
Date
8/28/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
c
=
=
=
=
=
5,021.4
0.0260
56.0
261.5
0.0690
23.0
46.3
0.0690
26.3
474.8
0.0690
33.0
300.5
0.0690
31.9
118.6
0.0690
26.0
105.0
0.0690
27.1
212.8
0.0690
28.8
73.0
0.06901
1 31.2
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Skylight
Skylight
Skylight
Skylight
C1
A2
D01
A3
Al
Oriantatinn
(1/109
W
(►M
(W)
(N)
(N)
(N)
(N)
(N)
Page Total
Shaded Unshaded
112 OF
78 OF
34 OF
Btu/hr
7,311
415
84
1,081
661
213
196
423
1 10,5421
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
-
=
c
=
=
=
-
0.0
6.8
4.0
20.4
0.0
6.8
4.0
20.4
0.0
6.8
12.6
20.4
0.0
6.8
4.0
20.4
0.0
12.9
58.0
12.9
0.0
12.9
50.0
12.9
0.0
45.7
60.0
45.7
0.0
12.9
179.0
12.9
0.0
12.9
23.0
12.9
Page Total
Btu/hr
81
81
257
81
745
643
2,742
2,300
296
7.226
Internal Gain Btu/hr
Occupants 15.1 Occupants X 245 Btuh/occ. = 3,709
Equipment 5,046 Floor Area X 0.50 W/sgft = 8,611
Infiltration: 1.064 X 0.88 X 231.25 X 36 = 7,829
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,6151
Latent Gain Btu/hr
Occupants 15.1 Occupants X 155 Btuh/occ. = 2,34E
Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.3461
6.7
s
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Filler & Sandy Investments, LLC 8/28/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Zone Outdoor Dry Bulb Temperature 112 OF
Floor Area 5,046.0 ft' Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF
Opaque Surfaces
R-21 Wall (W..21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
'R-13 Wall
Orientation
(►M
(NW)
(N)
Area
X
X
X
X
X-
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
98.5
0.0690
33.0
152.0
0.0690
31.5
78.0
0.0690
29.0
945.0
0.1020
0.0
5.7
12.9
0.0
12.9
5.7
12.9
0.0
12.9
5.7
12.9
0.0
12.9
4.0
16.2
0.0
12.9
64.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
D29
S2
P1
P2
P12
L4
K4
K6
P11
Internal Gain
Orientation
(N)
(N)
(N)
(N)
(N)
(NE)
(NE)
(NE)
(NE)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
13.9
144.0
13.9
0.0
12.9
20.4
12.9
0.0
12.9
5.7
12.9
0.0
12.9
5.7
12.9
0.0
12.9
5.7
12.9
0.0
12.9
4.0
16.2
0.0
12.9
64.0
16.2
0.0
12.9
36.0
16.2
0.0
12.9
5.7
16.2
Page Total
01
1,994
262
73
73
585
93
15.1 Occupants X 245 Btuh/occ. - 3,709
5,046 Floor Area X 0.50 w/sqn = 8,611
Infiltration: 1.064 X 0.88 X 231.25 X 36 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,6151
Latent Gain Btu/hr
Occupants 15.1 Occupants X 155 Btuh/occ. = 2,346
Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351
Air Sensible CFM ELA AW
W1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Zone Outdoor Dry Bulb Temperature
Floor Area 5,046.0 ft2 Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranae:
ue Surfaces
Orientation
Date
8/28/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
-
0.0
12.9
68.0
19.5
0.0
12.9
68.0
19.5
0.0
12.9
68.0
19.5
27.5
12.9
0.0
24.1
39.5
13.9
10.5
25.1
0.0
12.9
22.0
24.1
0.0
12.9
5.7
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FwnPctratinn
C2
C3
C4
N1
D19
M1
P10
L3
D17
Orientation
(NE)
(NE)
(NE)
(E)
(E)
(E)
(E)
(SE)
(SE)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X1
X
GLF
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
12.9
68.0
19.5
0.0
12.9
68.0
19.5
0.0
12.9
68.0
19.5
27.5
12.9
0.0
24.1
39.5
13.9
10.5
25.1
0.0
12.9
22.0
24.1
0.0
12.9
5.7
24.1
0.0
12.9
60.0
17.9
21.2
14.61+
8.8
20.1
Page Total
112 OF
78 OF
34 OF
Btu/hr
0
Btu/hr
1,328
1,328
1,328
353
811
531
138
1,072
7
Internal Gain Btu/hr
Occupants 15.1 Occupants X 245 Btuh/occ. 3,709
Equipment 5,046 Floor Area X 0.50 w/sgft = 8,611
Infiltration: 1.064 X 0.88 X 231.25 X 36 = C
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,61
Latent Gain Btu/hr
Occupants 15.1 Occupants X 155 Btuh/occ. = 2,34E
Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351
Air Sensible CFM ELA OW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.3461
EneravPro 6.7 by EnerovSoR User Number: 6712 Run Code: 2015-08-28716:53:47 /D: Paae 45 of 54 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Zone Outdoor Dry Bulb Temperature
Floor Area 5,046.Oft' Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Range:
Surfaces
Orientation
Date
8/28/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
c
44.5X
12.9+
5.9
17.9=
29.0
12.9
0.0
17.9
93.0X
13.9+
0.0X
18.9=
37.7
12.9
0.0
17.9
0.0
12.9
5.7
17.9
0.0
12.9
5.7
17.9
0.0
12.9
5.7
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fpnpstratinn
K3
K5
D16
K2
P9
P8
P6
P7
D15
Orientation
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(S)
(S)
(SW)
Shaded Unshaded
Area
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
i
X
GLF
=
=
=
=
=
=
c
44.5X
12.9+
5.9
17.9=
29.0
12.9
0.0
17.9
93.0X
13.9+
0.0X
18.9=
37.7
12.9
0.0
17.9
0.0
12.9
5.7
17.9
0.0
12.9
5.7
17.9
0.0
12.9
5.7
12.9
0.0
12.9
5.7
12.9
165.0
13.9
0.0
16.3
Page Total
112 OF
78 OF
34 OF
Btulhr
677
373
1,288
484
102
102
74
74
2,285
Internal Gain Btu/hr
Occupants 15.1 Occupants X 245 Btuh/occ. = 3,709
Equipment 5,046 Floor Area X 0.50 w/sgft = 8,611
Infiltration: 1.064 X 0.88 X 231.25 X 36 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,615
Latent Gain Btu/hr
Occupants 15.1 Occupants X 155 Btuh/occ. = 2,34E
Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 = 3,351
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.3461
EnerovPro6.7 by EnerovSoft User Number: 6712 RunCode: 2015-08-28T16:53:47 ID: Paae 46 of 54 1
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Room Name
Floor Area
Indoor Dry Bulb 1
Opaque Surfaces
V DESIGN CONDITIONS
Living Zone Outdoor Dry Bulb Temperature
5,046.0 ft2 Outdoor Wet Bulb Temperature
rature 76 OF Outdoor Dailv Ranae:
Orientation
Date
8/28/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
=
79.2
12.9
0.0
15.3
24.0
12.9
0.0
15.3
220.0
13.9
0.0
16.3
0.0
12.9
102.0
15.3
100.0
13.9
0.0
16.3
0.0
12.9
68.0
17.4
0.0
14.6
33.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
K1
Window
D12
J1
11
C6
D05
C5
D28
Internal Gain
Oripntatinn
(SIM
(SIM
(SIM
(S K9
(SIM
(SIM
(SIM
(SIM
t'►M
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
79.2
12.9
0.0
15.3
24.0
12.9
0.0
15.3
220.0
13.9
0.0
16.3
0.0
12.9
102.0
15.3
100.0
13.9
0.0
16.3
0.0
12.9
68.0
17.4
0.0
14.6
33.0
19.6
0.0
12.9
68.0
17.41
144.0
13.9
1 0.0
25.1
Page Total
15.1 Occupants X 245 Btuh/occ.
5,046 Floor Area X 0.50 W/sgft
Infiltration: 1.064 X 0.88 X 231.25 X 36 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
15.1 Occupants X 1 155 Btuh/occ.
Infiltration: 4,771 X 0.88 X 231.25 X 0.00344 =
Air Sensible CFM ELA AW
•I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
112 OF
78 OF
34 OF
Btu/hr
tnumr
1,018
308
3,047
1,561
1,385
1,182
647
1,182
1,9941
Btu/hr
3,709
8,611
7,829
69,615
Btu/hr
2,346
3,351
2.346
C
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Filler & Sandy Investments, LLC
8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living Zone
Outdoor Dry Bulb Temperature
112 OF
Floor Area 5,046.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btulhr
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
_
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btu/hr
S1 (IM 20.4 X 12.9 +
0.0 X
24.1 =
262
P3 (IM 0.0 X 12.9 +
5.7 X
24.1 =
138
P4 (IM 0.0 X 12.9 +
5.7 X
24.1 =
138
P5 (IM 0.0 X 12.9 +
5.7 X
24.1 =
138
R1 (NIM 0.0 X 12.9 +
18.0 X
21.3 =
383
81 (N) 0.0 X 12.9 +
13.5 X
19.0 =
256
B2 (N) 0.0 X 12.9 +
13.5 X
19.0 c
256
X +
X
=
X 1+1
X
=
Page Total
1,569
Internal Gain
Btu/hr
Occupants 15.1 Occupants X 245
Btuh/occ.
=
3,709
Equipment 5Floor Area X 0.50
w/sgft
=
8,611
Infiltration: 1.064 X 0.88 X 231.25 X 36 =
7,829
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
69,615
Latent Gain
Btu/hr
Occupants 15.1 Occupants X 155
Btuh/occ.
Infiltration: 4.771 X 0.88 X 231.25 X 0.00344 =
3,351
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2,346
EnemyPro 6.7 by EnemySoft User Number., 6712 RunCode: 2015-08-28716:53:47 ID:
Page 48 of 54
C:
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Filler & Sandy Investments, LLC
1 8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest 1
Outdoor Dry Bulb Temperature
112 OF
Floor Area 429.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic (W) 429.0 X 0.0260
X
56.0 =
625
R-21 Wall (W.21.2x6.16) (SIM 25.0 X 0.0690
X
31.2 =
54
R-21 Wall (W.21.2x6.16) (NW) 5.0 X 0.0690
X
31.5 =
11
R-21 Wall (W.21.2x6.16) (NIM 59.0 X 0.0690
X
29.9 =
122
`R-13 Wall 455.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
811
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btulhr
Ff (SW) 40.0 X 12.9 +
0.0
X 17.4 =
514
D06 (NW) 31.1 X 14.6 +
58.9
X 23.9 =
1,861
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
2.37
Internal Gain
Btu/hr
Occupants 1.3 Occupants X 245
Btuh/occ.
=
315
Equipment 429 Floor Area X 0.50
w/sgft
=
732
Infiltration: 1.064 X 0.88 X 19.66 X 36 =
666
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
4,899
Latent Gain
Btu/hr
Occupants 13 Occupants X 155
Btuh/occ.
=
199
Infiltration: 4,771 X 0.88 X 19.66 X 0.00344 =
285
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
199
EnerqyPro6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-28T16:53.47 /D:
Page 49 of 54
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
Room Name Guest 2 Outdoor Dry Bulb Temperature
Floor Area 742.0 ft2 Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF I Outdoor Dailv Ranae:
ODaaue Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
'R-13 Wall
Orientation
(M
(NE)
(SE)
(S K9
(SVtq
(NKK
(NW)
Date
8/28/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
742.0
0.0260
56.0
100.0
0.0690
26.3
286.5
0.0690
31.9
50.0
0.0690
28.8
137.0
0.0690
31.2
101.0
0.0690
31.5
85.0
0.0690
29.9
285.0
0.1020
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
d02
E1
D1
D2
D03
E2
E2
D04
(NE)
(NE)
(SE)
(SK9
(NW)
(NKK
(NW)
(NW)
112 OF
78 OF
34 OF
Btu/hr
1,080
182
630
99
295
219
175
0
1 2,6821
Shaded
Area
0.0X
0.0 X
0.0 X
0.0 X
Unshaded
GLF Area
13.9+ 80.0X
12.9 + 40.0
12.9 + 58.5
12.9 + 18.0
13.9 + 38.1
12.9 + 8.0
12.9 + 16.0
14.6 + 80.0
+1
X
X
X
X
X
X
X
X
GLF
17.2=
16.2
c
17.9
=
17.4 =
22.3 =
21.3 =
21.3 =
21.3
=
Page Total
41.9
X
0.0
X
0.0
X
0.0
X
X
Btu/hr
1,380
650
1,045
313
1,429
170
340
1,708
7
Internal Gain Btulhr
Occupants 2.2 Occupants X 245 Btuh/occ. = 545
Equipment 742 Floor Area X 0.50 w/sgft = 1,266
Infiltration: 1.064 X 0.88 X 34.00 X 36 = 1,151
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,6791
Latent Gain Btu/hr
Occupants 2.2 Occupants X 155 Btuh/occ. = 345
Infiltration: 4,771 X 0.88 X 34.00 X 0.00344 = 493
Air Sensible CFM ELA AW
I EnemyPro 6.7 by EnergySoft User Number., 6712 RunCode: 201 5-08-2 8 77 6:53:47 ID: Page 50 of 54 I
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
' Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
8/28/2015
mName
Casita
Outdoor Dry Bulb Temperature
112 °F
rtoorArea
2,298.0 f1Z
Outdoor Wet Bulb Temperature
78 °F
or Dry Bulb Temperature
76 OF
Outdoor Daily Range:
34 OF
Ooaaue Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W..21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (1N.21.2x6.16)
R-21 Wall (W 21.2x6.16)
R-21 Wall (W 21.2x6.16)
R-21 Wall (W.21.24.
Orientation
(1/10
(N)
(NE)
(NE)
(E)
(SE)
(S)
(S)
(S)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
2,298.01
0.0260
56.0
131.0
0.0690
24.3
154.0
0.0690
30.3
156.0
0.0690
30.8
540.0
0.0690
32.6
60.8
0.0690
28.8
55.0
0.0690
27.1
87.1
0.0690
12.9
58.0
0.0690
27.1
Page Total L
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration OriPntatinn Area GLF Area GLF
U7
U5
U2
W4
W2
U1
T2
D60
T1
Internal Gain
(N)
(N)
(N)
(NE)
(NE)
(E)
(SE)
(SE)
(SE)
0.0
X
X
X
X
X
X
X
X
X
12.9
+
+
+
+
+
+
+
+
+
50.0
X 14.2
X 14.2
X 14.2
X 20.7
X 20.7
X 23.7
X 17.3
X 53.3
X 15.3
Page Total
c
=
=
c
=
=
=
=
-
0.0
12.9
27.0
0.0
12.9
12.0
1.9
12.9
4.1
6.1
12.9
23.9
0.0
12.9
10.0
60.0
14.6
0.0
60.0
45.7
0.0
60.0
12.9
0.0
6 9 Occupants X 245 Btuh/occ. _
2,298 Floor Area X 0.50 w/sgft =
Infiltration: 1.064 X 0.88 X 105.31 X 36 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
6 9 Occupants X 1 155 Btuh/occ. _
'Infiltration: 4,771 X 0.88 X 105.31 X 0.00344 =
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR RO
Btu/hr
3,346
220
322
331
1,213
121
103
156
108
5,921
710
384
170
109
573
237
876
2,742
771
Btu/hr
1,689
3,922
3,566
40,718
Btu/hr
1,069
1,526
1.069
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC '
ROOM INFORMATION DESIGN CONDITIONS
Date
8/28/2015
Name
Casita
Outdoor Dry Bulb Temperature
112Area
r
2,298.0ft2
Outdoor Wet Bulb Temperature
78 °F
r Dry Bulb Temperature
76 OF
Outdoor Daily Ranqe:
34 OF
ODaaue Surfaces
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
'R-13 Wall
Orientation
(SW)
(tM
(W)
(NW)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
_
=
=
=
=
=
=
=
=
120.0
0.0690
31.7
225.9
0.0690
33.0
198.4
0.0690
32.4
264.0
0.0690
29.3
285.0
0.1020
0.0
12.9
0.0
13.9
55.0
12.9
0.0
13.9
123.0
13.9
0.0
13.9
33.9
12.9
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fanactratinn
Y4
T6
T5
T4
T3
D68
Y3
U4
V3
Orientation
(SE)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(SM
Shaded Unshaded
Area
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
GLF
=
=
=
=
=
-
0.0
12.9
23.2
15.3
55.0X
12.9+
0.0X
13.9=
55.0X
12.9+
0.0X
13.9=
56.0
12.9
0.0
13.9
55.0
12.9
0.0
13.9
123.0
13.9
0.0
13.9
33.9
12.9
0.0
12.9
0.0
12.9
12.0
13.9
30.0
12.9
0.0
17.7
Page Total
514
443
534
0
1,754
Btulhr
355
707
707
720
707
1,704
436
166
386
5,886
Internal Gain Btu/hr
Occupants fi.9 Occupants X 245 Btuh/occ. = 1,689
Equipment 2,298 Floor Area X 0.50 w/sgft = 3,922
Infiltration: 1.064 X 0.88 X 105.31 X 36 = 3,566
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40.718
Latent Gain Btu/hr
Occupants 6 9 Occupants X 155 Btuh/occ. = 1,069
Infiltration: 4,771 X 0.88 X 105.31 X 0.00344 = 1,526
Air Sensible CFM ELA AW
0 1
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1
It ,
0
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler & Sandy Investments, LLC
ROOM INFORMATION DESIGN CONDITIONS
Room Name Casita Outdoor Dry Bulb Temperature
Floor Area 2,298.0 ft' Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranoe:
Opaque Surfaces Orientation
Date
8/28/2015
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
D67
Y2
Y1
W5
D64
U6
U3
D66
W3
AriPntatinn
(►M
(tM
ftM
NO
(tM
NO
(NVIO
(NI/19
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
13.9
48.0
25.1
12.6
12.9
0.0
24.1
90.9
12.9
50.6
24.1
3.0
12.9
5.0
24.1
21.4
14.6
13.6
25.8
11.2
12.9
11.8
23.0
0.0
12.9
53.6
23.0
0.0
13.9
70.0
20.0
0.0
12.9
22.0
1 19.0
Page Total
112 °F
78 °F
34 OF
0
tstumr
1,206
162
2,389
159
663
415
1,232
1,397
417
8,041
Internal Gain Btu/hr
Occupants . 6 9 Occupants X 245 Btuh/occ. = 1,669
Equipment 2,298 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.88 X 105.31 X 36 = 3,566
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,71E
Latent Gain
Btu/hr
Occupants
6 9 Occupants
X 155 Btuh/occ.
= 1,069
Infiltration: 4,771
Air Sensible
X 0.88
CFM
X 105.31 X 0.00344 =
ELA AW
1,526
1
EnemyPro 6.7 by EnemySoft User Number., 6712 Run Code: 2015-08-28716:53:47 /D: Page 53 of 54 1
L`
0
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Filler & Sandy Investments, LLC
1 8/28/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 2,298.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area GLF
Btu/hr
W1 (NVt9 0.01 X 12.9 +
38.0 X
19.0 =
721
V4 (NVtq 0.0 X 12.9 +
38.0 X
19.0 =
721
V2 (NVt9 0.0 X 12.9 +
22.0 X
19.0 =
417
D65 (NIA9 0.0 X 13.9 +
70.0 X
20.0 =
1,397
Vl (NVt9 0.0 X 12.9 +
6.0 X
19.0 =
114
X +
X
=
X +
X
=
X +
X
=
X +1
X
=
Page Total
3,369
Internal Gain
Btu/hr
Occupants 6.9 Occupants X 245
Btuh/occ.
=
1,689
Equipment 2,298 Floor Area X 0.50
w/sgft
=
3,922
Infiltration: 1.064 X 0.88 X 105.31 X 36 =
3,566
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
40,716
Latent Gain
Btu/hr
Occupants 6 9 Occupants X 155
Btuh/occ.
=
1,069
Infiltration: 4,771 X 0.88 X 105.31 X 0.00344 =
1,526
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,069
Ene Pro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-28716:53:47 /D:
Page 54 of 54