Loading...
BRES2016-0247 Title 24Design Concepts _ Drafting $ De5ign Service Phone (760)365-8742 5744529 Palms Hwy., 5uite 304 - fax'(760)365-8743 Yucca Valley, CA 92284 - E -Mail: de5icgn.onhne@verizon.net ,Title 24 Energy Compliance Documentation Wright Project' Contento ; La Quinta,-CA .. - Climate Zone' 15 : 8-25-16 Method of compliance: 'Performance Method'using CBECC-RES 2013-4. This project is in compliance with the 2013 Edition of the California Residential Energy Efficiency Standards when built as documented in this submittal. Space Heating: 10,900 btu @'47 degrees 6,700 btu @,17 degrees. i t Air Conditioning: 2 mini splits -16 '"seem _ Water Heater: N/A„ Glazing: s Type Ufactor SHGC _ French door .32 29RE Sidelite 26 .16 l Q�-OF lAul T A Fixed - ` SA� l� (� XO a 51 -.36 ,±� � p�''f� .1�UINTA - f 66MMY9LOP ENT Wall Insulation: R-21 . Ceiling Insulation: �. R-60:" AUG 2 6.2016 CITY OF LA QUINTA COU 610 TV"'EVELOM10ENT CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 _ Project Name: Wright Calculation Date/Time: 09:46, Wed, Jul 27, 2016 Page 1 of 6 Calculation Description: Wright Input File Name: Wright.ribd GENERAL INFORMATION 01 Project Name Wright 02 Calculation Description _ 03 Project Location 81920 Contento 04 City La Quinta, Ca 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2013-4 (744) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly Constructed (Addition Alone) 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 397 15 Number of Zones 2 16 Slab Area (ft2) 397 17 Number of Stories 1 ` 18 Addition Cond. Floor Area 397 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 397 21 Glazing Percentage (%) 23.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance!-„ 02 This building incorporates features, ,!hat require field testing'and/orVerification;,by a certi bd-AERS rater,under the supervision of a CEC-approved HERS provider. i.._.tk 03 This building incorporates one'or�rnore Special Features shown below IVsr ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 12.41 11.15 1.26 10.2% y !' Space Cwooling ®- 201.45 201.16 0.29 0.1% IAQ _Ventklat6 11.26 11.26 0.00 0.0% Wa!LerW1atin0.00 0.00 0.00 0.0% Photo o t� jl ffset ---- 0.00 0.00 ____ Co`plianc6gyEal 225.12 223.57 1.550.7% rn �M�� o0-0� Registration u ber: 216-NO274992 - 00 00000-0000 Registration Date/Time: 2016-07-27 09:49:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency 5tan ar s - 013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-27 09:47:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wright Calculation Date/Time: 09:46, Wed, Jul 27, 2016 Calculation Description: Wright Input File Name: Wright.ribd REQUIRED SPECIAL FEATURES 'he following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Ceiling has high level of insulation Window overhangs and/or fins CF1 R -PRF -01 , Page 2 of 6 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: • Refrigerant Charge HVAC Distribution System Verifications: --None -- Domestic Hot Water System Verifications: f n --None -- ENERGY DESIGN RATING r This is the sum of the annual TDV energy consumption for energy use components included in the performance_��compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated'by'Title 24, Part 6,(sucF as -domestic appliances,and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. r Reference Erier lyse "! E 9y _ Energy Design Rating � Margin Percent Improvement Total Energy (kTDV/f2-yr)* 12770.12{;; ( 268.57 1.55 0.6% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURESJNEORMA 1 j -nD 02 03 04 05 06 07 fll Zone Floor Area Avg. Ceiling 0310102 03 04, 05 06 07 Piolm -nN e t Named adi Toned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems ight 397 1 2 2 0 0 198.5 9 ZONE INFOR TION Z 1 j -nD 02 03 04 05 06 07 fll Zone Floor Area Avg. Ceiling Zone N me one Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 Zor e 1 Q D onditioned HVAC System 1 198.5 g Zo e 2 -D nditioned HVAC System 2 198.5 9 II I Registration Number: 216-N0279982B-000000000-0000 Registration Date/Time: 2016-07-27 09:49:22 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-27 09:47:14 c CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wright Calculation Date/Time: 09:46, Wed, Jul 27, 2016 Calculation Description: Wright Input File Name: Wright.ribd CF1 R -PRF -01 Page 3 of 6 OPAQUE SURFACES 01 02 *� U5 Name Type 08 .front bedroom 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) z1 front Zone 1 exterior walls 180 Front 112.5 25 90 z1 left Zone 1 exterior walls 270 Left 153 22.5 90 Ceiling (below attic) 1 Zone 1 ceiling 8.0 1 198.5 0.26 0.16 z2 back Zone 2 exterior walls 0 Back 112.5 40 90 z2 left - Zone 2 exterior walls 270 Left 153 4.5 90 Ceiling (below attic) 2 Zone 2 ceiling 198.5 ATTIC 01 02 03 04 05 106 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic 1 Asphalt Shingle Roof Ventilated 4 0.1 0.85 Yes No WINDOWS 01 02 *� U5 Name Type 08 .front bedroom Window �7€ � :e (Orientation -Azimuth) front bath Window � Y ip IMulti li er back bed back bed back bed back b HIC 0= IM It o im(r- U � 4 t� 04 � *� U5 Ofi� ` w 07) 08 09 10 �7€ � :e (Orientation -Azimuth) � � •' Width (ft) Height (ft) � Y ip IMulti li er Area (ftZ) U -factor ' SHGC Exterior Shading z1 front (Front -180) 5.0 5.0 1 25.0 0.51 0.36 Insect Screen (default) z1 left (Left -270) z1 left (Left -270) 3.0 2.0 1.5 3.0 1 3 4.5 18.0 0.51 0.37 0.36 0.38 Insect Screen (default) None z2 back (Back -0) 3.0 8.0 1 24.0 0.32 0.29 None z2 back (Back -0) 2.0 8.0 1 16.0 0.26 0.16 None z2 left (Left -270) 3.0 1.5 1 4.5 0.51 0.36 Insect Screen (default) Registration Number: 216-NO2799828-000000000-0000 Registration Date/Time: 2016-07-27 09:49:22 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 roo{� Window french Wirerow� s sId lite O i t WinM !� M®D C: M MCC Z HERS Provider: CaICERTS inc. Report Generated at: 2016-07-27 09:47:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wright Calculation Date/Time: 09:46, Wed, Jul 27, 2016 Calculation Description: Wright Input File Name: Wright.ribd CF1 R -PRF -01 Page 4 of 6 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up front bedroom 2 1 4 20 0 0 0 0 0 0 0 0 0 front bath 0 0 0 0 0 0 0 0 0 0- 0 0 0 back bedroom 0 0 0 0 0 0 0 0 0 0 0 0 0 back bed french 2 1 3 6 0 0 0 0 0 0 0 0 0 back bed sidelite 2 1 6 4 0 0 0 0 0 0 0 0 0 back bath 0 0 0 0 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 03 04 05 Total Cavity Winter Design ame 5u T1 Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Zone 1 198.5 59 i >i " No Cavity/ Frame: no insul. / 2x4 Top Chrd Asphalt Shingle Roof p g Attic Roofs Wo Fr Wood Framed Ceiling 2x4/opChord of,Roof Truss 24. f @ O.C: 0.8 0.616 Roof Deck: Wood Sidin /sheathin /deckin 9' 9 9 Roofing: e* . • h m_ h _ , none 10 PSF (RoofTile) Ceilings (below H E , -i s �+- z Inside Finish: Gypsum Board Cavity/Frame: R-9.1 /2x4 ceiling attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 60 0.016 Over Floor Joists: R-50.9 insul. ,✓� � C, e Inside Finish: Gypsum Board i O- Cavity / Frame: R-21 / 2x6 rii -n Sheathing/ Insulation: Wood i L� 4xt Siding/sheathing/decking ext rior wall rior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.065 1 Exterior Finish: 3 Coat Stucco SLAB FLO S Q t Im 01 U? °' U7 LC02 03 04 05 06 07 ame 5u T1 Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated SI On Grana Zone 1 198.5 59 None 0.8 No SI b On Gra O FR- Zone 2 198.5 59 None 0.8 No Registration Number: 216-N0279982B-000000000-0000 Registration Date/Time: 2016-07-27 09:49:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-07-27 09:47:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 _ Project Name: Wright Calculation bate/Time: 09:46, Wed, Jul 27, 2016 Page 5 of 6 Calculation Description: Wright Input File Name: Wright.ribd BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name :Heat Pum System 1:::2 P y Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 None None :Heat Pum System 2:::2 P Y Heat Pump Heating and Cooling Systeme Heat Pump System 2 Heat Pump System 2 None None HVAC - HEAT, PUMPS 01 02— 03 1 04 05 06 1 07 08 09 10 Name ` 5 Type f Heating Cooling Verified Refrigerant Charge Zonally Multispeed HERS Not Required Not Required 'HSPF/COP Cap 470 Ca� r r pc 1�7 * SEER EERY , r k Controlled /`f Compressor p Verification Heat Pump System 1 ,J ! DuctlessH atPump 8!2 LL 10900 6700 � 16 y� 13 , No No Heat Pump System 1 -hers -cool Heat Pump -System 2 Ductless Pump '-- 2 10 0 i `'� 67100' 16� 13�' No No Heat Pump System 7i -' L 2 -hers -cool nvNt, t.UULIN - KtKST VEKIFIGjATdQf;V ® 02 03 04 OS 06 me fn rr Z Q° Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump s 1-he4I 5 Not Required ---- Not Required Not Required Required Heat Pump S em 2 -his- 1 Not Required Not Required Not Required Required I I R 0002 Z�-� Registration Number: 216-N0279982B-000000000-0000 Registration Date/Time: 2016-07-27 09:49:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-27 09:47:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wright Calculation Date/Time: 09:46, Wed, Jul 27, 2016 Calculation Description: Wright Input File Name: Wright.ribd CF1 R -PRF -01 _ Page 6 of 6 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete: Documentation Author Name: Documentation Author Signature: Brian Diebolt Company: Signature Date: Design Concepts 2016-07-27 09:49:22 Address: CEA/HERS Certification Identification (If applicable):.: 57445 29 Palms Hwy, Ste 304 City/State/Zip: Phone: Yucca Valley, CA 92284 760-365-8742 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the. State of California: +. - 1. 1 am eligible under Division 3 of the Business and Professions Code to accept•responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. _- 3. The building.design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted t the enforcement.agency,for approval,with,thi -building permit application. Responsible Designer Name: flot iRe�spon'sible Designer Signaure: t . Brian Diebolt ' ,��r � {-• iR'� >�� �' .� � Company: Design Conte^ E,R. S Date. Signed: � E R!� 2016-07 27 09.4922 Address::f4 G -- 4M License: 57445 29 Hwyat' 000 ' City/State/Zip: Z ® Yucca Valley, A 9225 T Z —� Phone: p -- 760-365-8742 Digitally signed by information. i�vi CT� C:M�C: C) z Z M� 1 ERTS. This diaita/ sionatui is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the Registration Number: 216-N0279982B-000000000-0000 Registration Date/Time: 2016-a7-2709:49:22 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-27 09:47:14 n