Loading...
07-1486 (RER) Title 24, TITLE 24 REPORT CITY O1= LA QUINTA BUILDING & SAFETY DEPT. APPROVED - FOR CONSTRUCTION DAT1419i gy _0� Title 24 Report for: A.P.N. 604-451-005 79673 Dandelion Dr. La Quinta, CA 92253 Project Designer: Report Prepared By: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Number: Ig051507 Date: 5/17/2007 0 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: Ig051507 User Number: 5732 I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary I 1 2 3 7 9 EnergyPro 4.3 by EnergySoft Job Number: Ig051507 User Number: 5732 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R - -P_X- 6.0�451_Q05 ] Single Family ❑ Addition Total Conditioned Floor Area: 5l_1712_Q07 Project Title 19673_Daadelion Dr I a Quiata Existing Floor Area: Building Front Orientation: Date Project Address Fuel Type: Natural Gas Building Permit # Santiago�o�ezOcampo Documen tion Author (760) 485-8927 Telephone Area: Plan Check/Date �EL1et�r�c0 Compli ce Method Number of Dwelling Units: Ratio: CA Climate Clirf lognil r% Number of Stories: ` Field Check/Date TDV Standard Proposed Compliance Units Zone Type Type _ kBtu/sf-yr) Design Design Margin Space Heating 6.10 1.54 4.56 Space Cooling 137.28 125.57 11.71 Fans 18.43 16.69 1.74 Domestic Hot Water 10.50 10.50 0.00 Pumps 0.00 0.00 0.00 Totals 172.31 154.30 18.01 Percent better than Standard: 10. Building Type: ] Single Family ❑ Addition Total Conditioned Floor Area: Existing_ D -9:A3 ❑ Multi Family, EX -1 Existing + Add/Alt Existing Floor Area: Building Front Orientation: (N) 0 deg Raised Floor Area: Fuel Type: Natural Gas Slab on Grade Area: Fenestration: Average Ceiling Height: Area: 338 ft2 Avg. U: 0.82 Number of Dwelling Units: Ratio: 13.5% Avg. SHGC: 0.66 Number of Stories: ` BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type J±VAC_Systern 2 5,105+10 -2W0 100_ _Conditioned--Setback- OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rool Wood- -2.5].0_ -0-04.9 Rs9_ _R-0._0_ -0_x.8 Wall- Wood_ 32 -0 1DZ X1.3_ -0 0 x.5_ 9.0 Wall_ Wood_ 417 x-102 R-13 R-0 0_ Q 9Q .Dooms Drone- 40 -0-5Il0_ done R_n n x_ 9.0 -Dooms D1one 18 -0_500_--None- _BSD_ 0 9D Wall_ Wood_ 52.6- _0102 R-13 _R-0.0 X090 Wall_ Wood_ 416 _0.102 R_13 -R--Oa 1A0 9 Wall_ Wood- -fi0.8_ _0102 R_13 R-0 0_ 270_ 9.0 2,510 ft2 2,510 ft2 0 ft2 2,510 ft2 10.0 ft 1.00 Vent Hgt. Area -2 -nla Gains Condition Y / N Status JA IV Reference Location / Comments Existing_ 01-A4 Whole -House Existing- _09_A3 Whole_aouse Existing_ D -9:A3 WholeJJ.ouse Existing- 28-A4 Whole -House Existing 28--A4 Existing 09-A3 Existing .0.9=A3 WholeJdouse WholeJiouse WholeJ3o.use Existing- D.9 A3 Whole -House EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig051507 Page:3 of 9 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R A.P.N. 604-451-005 5/17/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 1_ VNindov-Ernnt-(NE) X6_6. 9_38ONERC 0-36 2 Window Front (NE) 16.0 0.870 NFRC 0_70 3 Window Front (N) 16.0 0.870 NFRC 0_70 4 Window Front (N) 9.0 0.870 NFRC 0_70 5 Window Front (N) 5.0 0.870 NFRC 0_70 6 Window Front (N) 5.0 0.870 NFRC 0_70 7 Window Left (E)_ 14.0_ 0.870 NFRC 0.70 8 Window Left (E) 30.0 0.870 NFRC 0.70 9 Window Left (E)_ 48.0 0.870NERC 0.70 10 Window Rear (S)_ 96.0 _0.87 RC0.70 180 Window Rear (S) 10.0 0.870 NFRC 0_70 12 Window Rear (S) 10.0 0.870 NFRC 0_70 13 Window--Rear---(S) 1-6_006550BERC-.48 90 Existin _2001BuildEnergyStdMtl-DefQI. 14 Window Right (W)_ 20.0 0.870 NFRC 0_70 15 Window Right (W) 6.0 0.870 NFRC 0_70 16 Window Right W 20.0 0.870 NFRC 0_70 17 Window Right (W) 6.0 0.870 NFRC 0_70 -NERC 45 90_ New M. asoniteJntemationaLCorporation Whole±1ouse NFRC 45 90 Removed2001 BuildEnergyStdMtl-DefCI. Whole House NFRC 0 90 Existing 2001BuildEnergyStdMtl-DefCI. Left Fin Right Fin Whole House NFRC 0 90 Existing_ 2001 Build EnergyStdMtl-DefQI. Whole House NFRC 0 90 Existin _2001BuildEnergyStdMtl-DefCl. Whole House NFRC 0 90 Existing 2001BuildEnergyStdMtl-DefQI. 0.76 Whole House NFRC 90 90 Existing 2001 BuildEnergyStdMtl-DefCl 3 Bug Screen Whole House NFRC 90 90 Existing_ 2001 BuildEnergyStdMtl-DefC1. Whole House NFRC 90 90 Existing 2001 BuildEnergyStdMtl-DefCI. 60 Whole Fi�use NFRC 180 90 Existing 2001 Build EnergyStdMtl-DefCl. 6.0 0.1 6.0 Whole Quse NFRC 180 90 Existing 2001 BuildEneravStdMtl-DefQI. 5.0 1.0 Whole House NFRC 180 90 Existin _2001BuildEnergyS1dMt1-DefQI. 0.76 Whole House -NFRC NFRC 180_ 270 90 Existing_ IL- L0-CLC_Sx8x4-Nhole_House 90 Existing_2001BuildEnergyStdMt1-DefQI. Whole House NFRC 270 90 Existing 20016uildEnergyStdMtl-DefCl. Whole House NFRC 270 90 Existin _2001BuildEnergyStdMtl-DefQI. 0.76 Whole House NFRC 270 90 Existing_2001BuildEnergyStdMtl-DefCl. 10 Bug Screen Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 1.5 6.0 6.0 01 6. 60 5 Bug Screen 0.76 5.0 1.0 6.0 0.1 6.0 6.0 6 Bug Screen 0.76 5.0 1.0 6.0 01 _ 6.0 6.0 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 _ 16 Bug Screen 0.76 17 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 2,510 3.50 28 0.98 0 26-A1 Existing_ Whole House / Slab on Grade PERIMETER LOSSES Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 05/17/07 10:20:03 Run Code: 1179422403 EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig051507 Page:4 of 9 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R A.P.N. 604-451-005 5/17/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 4.2 Existing No Hydronic Piping . Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing_ 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft_ Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by thb individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name Title/Firm: Address: Telephone: Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: SLO Title/Firm: Santiago Lopez-Ocampo Address: P.O. Box 1018 La Quinta, CA 92247 Telephone: 760 485-8927 7-C? 7 (signature) (date) 'i EneravPro 4.3 by EneravSoft User Number: 5732 Job Number Ia051507 Paoe:5 of 9 I Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R A.P.N. 604-451-005 5/17/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist.' These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies, iaseu on the auequacy or cne sperwi jusnrication ano aocumentaaon suomm:ea. Plan Field HIGH MASS Design - Verify Thermal Mass: 2510 sqft Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field I EnerayPro 4.3 by EneMySoft User Number: 5732 Job Number: la051507 Paae:6 of 9 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ' ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El 11 ❑ ❑ CF -6R Form: Page:7 of 9 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Q ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1, First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic.heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig051507. Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. always on option." § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig051507 Page:8 of 9 § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms by dimmer OR ❑ ❑ ❑ shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled a switch are controlled by an occupant sensor that complies with Section fl 9(d) that does not turn on automatically or have an always on option." § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig051507 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE A.P.N. 604-451-005 5/17/2007 SYSTEM NAME FLOOR AREA HVAC System 2,510 Number of Systems 2 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuhlsgft) 0.0 Cooling System Output per System 1 Total Output (Btuh) 2 Total Output (Tons) 0.0 Total Output (Btuh/sgft) 0.0 Total Output (sgftlron) 15,060,000.0 0 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfmisgft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF — 0 Outside Air 0 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,784 43,673 3,385 881 37,488 0 8,778 5,370 0 0 0 0 0 0 0 0 0 8,778 5,370 61,230 3,385 48 229 Default FAU/AC 1992 - 2005 2 0 0 Total Adjusted System Output 2 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 70.0°F . 110.0°F Heating Coil >% Return Air Ducts 4 Supply Air Ducts 110.0 OF ROOMS 70.0 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F 78.0/62.3°F 55.0/53.7°F Supply Air Ducts Outside Air 0 cfm Cooling Coil 55.0 / 53.7 OF 41.2% R.H. FROOMS 78.0/62.2 °F 78.0 / 62.2 OF k Return Air Ducts "I EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig051507 Page:9 of 9 1