BRES2015-0352 Title 241 BUILDING ENERGY ANALYSIS +REPORT 4' PROJECT: Bihari Residence Lot 4 Traditions La Quinta, CA 92253 Project Designer: Helton Deford 17-411 Irvine Blvd. Tustin, CA 92780 (909) 957-4550 Report Prepared by: Tim Scott Scott Design and Title 24 0NNA 77085 Michigan Dri e(;IV & SA�E� pEPT- Palrn Desert, CA 92211gUILD 0VE- _ (760) 200-4780 App �� -TION FOR DATE Job Number: Nov ,:�C��11N� MENS Date: �o 10/28/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for,use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. w This program developed by EnergySoft, LLC —www.energysoft.com. Ene Pro 6.7 6 Ene Soft User Number: 6712 ID: CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE SHOD Project Name: New Residence Calculation Daterrime: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xml CIORF-01 Page 1 of 14 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name New Residence 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location Lot 4 Traditions Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version SEMCmpMgr 20134 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 6292 15 Number of Zones 5 16 Slab Area (ft2) 6292 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 26.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performa`nce"4 /r' " I F-` 02 This building incorporates features that require field-testing and/or venficatiomby a.certifiedliHERS rater under the supervision of a CEC-approved HERS provider. +"� y LZ ,mkk _#5 i! ai_ t __._ ar wi k4 -i .«t rf 14 Y1 %1.' r+ 03 This building incorporates one or,more Specpal R eaturesowbelow r=.. ;raw. Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.75 5.23 -0.48 -10.1% Space Cooling 125.54 119.62 5.92 4.7% IAQ Ventilation 0.71 0.71 0.00 0.0% Water Heating 4.08 4.55 -0.47 -11.5% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 135.08 130.11 4.97 3.7% Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTIOE OF COMPLIANCE -'RESIDENTIAL PERFORMANCE COMPLIANCE *HOD CIORF-01 Project Name: New Residence Calculation Daterrime: 15:23, Wed, Oct 28, 2015 Page 2 of 14 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xmi REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • Nigh Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM " HVAC Distribution System Verifications: f V • Duct Sealing 1•! Domestic Hot Water System Verifications:'. ,?-' - -None— ENERGY DESIGN RATING J This is the sum of the annual TDV energy consumption forlenergy usee om'ponentslincluded in -the performance compliance app Mach fc�-lhe'standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not>regulated by Title 24; PaftF6 (such as dorilestic=appliances`and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. ® ' *_�o V I LW V Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 170.42 165.45, 4.97 2.9% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems New Residence 6292 1 4 5 0 1 Registration Number: 215-1462967018-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD Project ame: New Residence Ca culation Daterrime: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xm1 C*RF-01 Page 3 of 14 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Kit Game room Conditioned HVAC 1 kit gamel 1471 9 DHW Sys 1 great bed 3 Conditioned HVAC 2 great bed 32 1478 9 DHW Sys 1 master Conditioned HVAC 3 mster3 1352 9 DHW Sys 1 media Conditioned HVAC 4media4 884 9 DHW Sys 1 guest Conditioned HVAC 5 guest5 1107 9, DHW Sys 1 t. • F AMCm*RT"p*H -'ERS- Registration Number: 215N6296701B-000000000-0000. Registration Date/Time: 201510-2816:40:37 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-08252015-744 v HERS Provider: CaICERTS inc. Report Generated at: 2015-10-28 15:25:15 CERTIIPE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE COD Project ame: New Residence Ca culation Date/Time: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xml C*RF-01 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall Kit Game room R-21 Wall (W.21.2x6.16) 0 Back 504 120 90 E Wall Kit Game room R-21 Wall (W.21.2x6.16) 90 Right 1100 315 90 S Wall Kit Game room R-21 Wall (W.21.2x6.16) 180 Front 200 90 W Wall Kit Game room R-21 Wall (W.21.2x6.16) 270 Left 1365 35.295 90 Roof Kit Game room R-38 Roof Attic 1471 N Wall 2 great bed 3 R-21 Wall (W.21.2x6.16) 0 Back 1104 260 90 E Wall 2 great bed 3 R-21 Wall (W.21.2x6.16) 90 Right 440 92 90 S Wall 2 great bed 3 R-21 Wall (W.21.2x6.16) 180 Front 1200 208 90 W Wall 2 great bed 3 R-21 Wall (W.21.2x6.16) 270 Left 600 24 90 Roof 2 great bed 3 R-38"Roof Attic 1478 N Wall 3 master R-21 Wall (W.21.2x6.16) 0 Back 875 120.9 90 E Wall 3 master R-21 Wall (W.21.2x6.16) 90 Right 90 78.3 90 S Wall 3 master "^ �. R-�21aWalh(1N21{2x6tY6)'RY80 Front 280 24 90 W Wall 3 master F: 21^Wall (1N21'2x'616)` .f'�'� ;7 1k bt an S� x`270 kt ft 'Left s 400 6 90 Roof 3 master h R=38%Roof Attie f '" D �' t 1352 N Wall 4 media k-,-21Walls(W.21 f2z6.16) (*r 1 BaGi ; 300 48 90 E Wall 4 media R-21 Wall (W.21.2x6.16) 90 Right 700 18 90 S Wall 4 media R-21 Wall (W.21.2x6.16) 180 Front 700 18 90 W Wall 4 media R-21 Wall (W.21.2x6.16) 270 Left 700 144 90 Roof 4 media R-38 Roof Attic 884 N Wall 5 guest R-21 Wall (W.21.2x6.16) 0 Back 800 120 90 E Wall 5 guest R-21 Wall (W.21.2x6.16) 90 Right 1000 30 90 S Wall 5 guest R-21 Wall (W.21.2x6.16) 180 Front 800 33.6 90 W Wall 5 guest R-21 Wall (W.21.2x6.16) 270 1 Left 1000 37.8 90 Roof 5 guest R-38 Roof Attic 1 1107 Registration Number: 215-N62967018-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE &OD Project Name: New Residence Calculation Date/Time: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xmi C*RF-01 Page 5 of 14 - ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Kit Game room Attic RoofKit Game room Ventilated 3 0.1 0.85 No No Attic great bed 3 Attic Roofgreat bed 3 Ventilated 3 0.1 0.85 No No Attic master Attic Roofmaster Ventilated 3 0.1 0.85 No No Attic media Attic Roofinedia Ventilated 3 0.1 0.85 No No Attic guest Attic Roofguest Ventilated 3 0.1 0.85 No No f `O'l C E RTS, -,I,. n r ` HERS PROVIDEM Registration Number: 215-N62967018-000000000-0000 Registration Date/Time: 201510-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IkOD Project Name: New Residence Ca culation Daterrime: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xmi C*RF-01 Page 6 of 14 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U -factor SHGC Exterior Shading 1K o Window N Wall (Back -0) 12.0 10.0 1 120.0 0.46 0.36 Insect Screen (default) 1 L o Window E Wall (Right -90) 9.0 10.0 1 90.0 0.46 1 0.36 Insect Screen (default) 1C o Window E Wall (Right -90) 22.5 10.0 1 225.0 0.46 0.36 Insect Screen (default) 106 f Window W Wall (Left -270) 3.0 2.0 1 6.0 0.39 0.24 Insect Screen (default) 107 f Window W Wall (Left -270) 3.0 2.0 1 6.0 0.39 0.24 Insect Screen (default) 108 f Window W Wall (Left -270) 2.5 4.5 1.004 11.3 0.39 0.24 Insect Screen (default) 109 f Window W Wall (Left -270) 3.0 2.0 1 6.0 0.39 0.24 Insect Screen (default) 110 f Window W Wall (Left -270) 3.0 2.0 1 j 6.0 0.39 0.24 Insect Screen (default) 1 M o Window N Wall 2 (Back -0) 20.0 10.0 1 200.0 0.46 0.36 Insect Screen (default) 1N o Window N Wall 2 (Back -0) 6.0 10.0 1 60.0 0.46 0.36 Insect Screen (default) 1 DD o Window E Wall 2 (Right -90) 2.5 8.0 1 20.0 0.46 0.36 Insect Screen (default) 1 D o Window E Wall 2 (Right -9 1 . t 9:0 f, 8.0 1 72.0 0.46 0.36 Insect Screen (default) 1A o Window S Wall 2 (Fr ntt-180) €« 4':0 L 9.0 1 J f1j) %'`36.0 0.46 0.36 Insect Screen (default) 1 B o Window �N S 1Nallr2-(Frontx,180) ` . 13.0 P k40-0 Ll U 1 U X130 0 0.46 0.36 Insect Screen (default) 105 f Window S Wall 22 (Front 180)> < 4:0'1 t ` 4�,-5 n g: X18.0 0.39 0.24 Insect Screen (default) 111 f Window N Wall 3 (Back -0) - - 1 2.3 0.39 0.24 Insect Screen (default) 112 f Window N Wall 3 (Back -0) - - 1 2.3 0.39 0.24 Insect Screen (default) 113f Window N Wall 3 (Back -0) - -- 1 2.3 0.39 0.24 Insect Screen (default) 1P o Window N Wall 3 (Back -0) - - 1 72.0 0.46 0.36 Insect Screen (default) 115f Window N Wall 3 (Back -0) - - 1 12.0 0.39 0.24 Insect Screen (default) 116f Window N Wall 3 (Back -0) -- - 1 18.0 0.39 0.24 Insect Screen (default) 117f Window N Wall 3 (Back -0) -- - 1 12.0 0.39 0.24 Insect Screen (default) 118f Window E Wall 3 (Right -90) - - 1 2.3 0.39 0.24 Insect Screen (default) 1Q o Window E Wall 3 (Right -90) - - 1 20.0 0.46 0.36 Insect Screen (default) 119f Window E Wall 3 (Right -90) -- - 1 12.0 0.39 0.24 Insect Screen (default) 120 f Window E Wall 3 (Right -90) - -- 1 12.0 0.39 0.24 Insect Screen (default) 121 f Window E Wall 3 (Right -90) - - 1 12.0 0.39 0.24 Insect Screen (default) 1 R o Window E Wall 3 (Right -90) - - 1 20.0 0.46 0.36 Insect Screen (default) 129 f Window S Wall 3 (Front -180) - -- 1 24.0 0.39 0.24 Insect Screen (default) Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 201510-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD Project ame: New Residence a , ation DatelTime: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xm1 C*RF-01 Page 7 of 14 114 f Window W Wall 3 (Left -270) - - 1 6.0 0.39 0.24 Insect Screen (default) 1T o Window N Wall 4 (Back -0) 6.0 8.0 1 48.0 0.32 0.24 Insect Screen (default) 123 f Window E Wall 4 (Right -90) 2.0 3.0 1 6.0 0.24 0.18 Insect Screen (default) 124 f Window E Wall 4 (Right -90) 2.0 3.0 1 6.0 0.24 0.18 Insect Screen (default) 125 f Window E Wall 4 (Right -90) 2.0 3.0 1 1 6.0 0.24 0.18 Insect Screen (default) 126 f Window S Wall 4 (Front -180) 2.0 3.0 1 6.0 0.24 0.18 Insect Screen (default) 127 f Window S Wall 4 (Front -180) 2.0 3.0 1 6.0 0.24 0.18 Insect Screen (default) 128 f Window S Wall 4 (Front -180) 2.0 3.0 1 6.0 0.24 0.18 Insect Screen (default) 11.10 Window W Wall 4 (Left -270) 18.0 8.0 1 144.0 0.32 0.24 Insect Screen (default) 1TT o Window N Wall 5 (Back -0) - - 1 20.0 0.46 0.36 Insect Screen (default) 1 W o Window N Wall 5 (Back -0) - - 1 64.0 0.46 0.36 Insect Screen (default) 130 f Window N Wall 5 (Back -0) - - 1 36.0 0.39 0.24 Insect Screen (default) 131 f Window E Wall 5 (Right -90) - - 1 6.0 0.39 0.24 Insect Screen (default) 1X o Window E Wall 5 (Right -90) - - 1 24.0 0.46 0.36 Insect Screen (default) 132 f Window S Wall 5 (Front -180) - - 1 6.0 0.39 0.24 Insect Screen (default) 133 f Window . " S V%11-5'(Front-180) /:,-M t: ar I� - 1 13.8 0.39 0.24 Insect Screen (default) 134 f Window S Wall 5 (Front X80) t r -- ?-11) -f3.8 0.39 0.24 Insect Screen (default) 1 V o Window W 1Nell 5;(Left-'270)°jam-L, U 1 t t X24"0 0.46 0.36 Insect Screen (default) 133 f 2- Window W WAS1,51(-4K2707.4 ? -^ 1 z 1" 1 13.8 0.39 0.24 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft2) U -factor 1AA S Wall 2 24.0 0.50 1EE W Wall 2 24.0 0.50 Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD Project Name: New Residence Calculation Date/Time: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xml CRF -01 Page 8 of 14 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 1Ko 10 0.1 10 10 0 0 0 0 0 0 0 0 0 11-o 10 0.1 10 10 0 0 0 0 0 0 0 0 0 1co 10 0.1 10 10 0 0 0 0 0 0 0 0 0 106f 8 0.1 8 8 0 0 0 0 0 0 0 0 0 107f 8 0.1 8 8 0 0 0 0 0 0 0 0 0 108f 8 0.1 8 8 0 0 0 0 0 0 0 0 0 109f 8 0:1 8 8 0 0 0 0 0 0 0 0 0 110f 8, 0.1 8 8 0 0 0 0 0 0 0 0 0 1M o 18 ' 0.1 18 18 0 0 0 0 0 0 0 0 0 1N o 7-18 0.1 18 _ 18 0 0 0 0 0 0 0 0 0 1DDo 118 0.1 j8 n 18,E 00--1'�� r' 0p 0 0 0 0 0 0 1D o 18 0.1 18p 1�8 0d 111 0 Oil Oft 0 0 0 0 0 1A o r18 g \#0.1 i ,�8t►-a� {1 i l� `1'8�i 1�.� �� 1� 0t+�r �# Oil I I E 0" t 0 0 0 0 0 113o rr'18 `N 0;1 &18C r.18C r in f'0, 6"1 0 On 0 0 0 0 0 105 f 18 O.1. "18 � X18' � 0 � ' `6 V d'" V.— e ` 0 0 0 0 0 1To 10 0.1 10 10 0 0 0 0 0 0 0 0 0 123f 6 0.1 6 6 0 0 0 0 0 0 0 0 0 124f 6 0.1 6 6 0 0 0 .0 0 0 0 0 0 125f 6 0.1 6 6 0 0 0 0 0 0 0 0 0 126f 6 0.1 6 6 0 0 0 0 0 0 0 0 0 127f 6 0.1 6 6 0 0 0 0 0 0 0 0 0 128f 6 0.1 6 6 0 0 0 0 0 0 0 0 0 1uo 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE.HOD Project Name: New Residence Calculation DatefTime: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xm1 CORF-01 Page 9 of 1.4 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Kit Game room 1471 125 None 0.8 No • Cavity/ Frame: no insul. /2x4 Top Chrd great bed 3 1478 200 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic RoofKit Game room Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) media 884 106 None 0.8 No • Inside Finish: Gypsum Board guest Ceilings (below 144 None 0.8 No Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgreat bed 3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) - Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed;Ceiling fm�O.C, � f none • 0.644 Roofing: Light Roof (Asphalt Shingle) tCavity 2x4 Top Chord of Roof Truss @ 24 )flnoJ / Frame: no insul. / 2x4 Top Chrd Roof Deck. Wood Siding/sheathing/decking Attic Roofinedia Attic Roofs 4 Wood Fra med-CeiIi g in O.0 U It 0:644 Roofing: Light Roof (Asphalt Shingle) t K► e K U V I U 1= ff. Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofguest Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Covered Slab Kit Game room 1471 125 None 0.8 No Covered Slab 2 great bed 3 1478 200 None 0.8 No Covered Slab 3 master 1352 110 None 0.8 No Covered Slab 4 media 884 106 None 0.8 No Covered Slab 5 guest 1107 144 None 0.8 No Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 2015-10-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD Project ame: New Residence ation Date/Time: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 ` Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required — C*RF-01 Page 10 of 14 WATER HEATING SYSTEMS 01 02,E 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/2 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS ..1� 01 02,E 03 04 05 06 07 08 F r Z 4-..o v 5 I- Ix Recirculation Tank Exterior Name Pipe Insulation `� Tank Volume Energy Factor or Distribution Insulation Standby Loss Name Heater Element Type Tank Type (gal) Efficiency Input Rating R -value (Fraction) DHW Heater 1 Natural. Gas ' – Small Storage 50 0.66 40000-Btu/hr 0 0 rip* if It WATER HEATING - HERS VERIFICATION,, • / 1�'' �» 01 �02� 'V 6 `03" `04 YID Mi/ -w •#+ ellc fey � .fM. t A 'R f4�. M `05 tAd /Ftir 06 07 F r Z 4-..o v 5 I- Ix Recirculation Central DHW Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Control Distribution DHW Sys 1-1/2 — — — — — — r Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 2015-10-2816:40:37 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-10-28 15:25:15 CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtIOD Project ame: New Residence Caation Date/Time: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xmi CI.RF-01 Page 11 of 14 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name. Fan Name Distribution Name :Heat Pump System 1:Air Distribution System Heat Pump Heating and Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 1:HVAC Fan 1:2 Cooling System Verification Heat Pump System 1 _ d #I 9 :Heat Pump System 2:Air Distribution System Heat Pump Heating and Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 2:HVAC Fan 2:2 Cooling System 1 r :Heat Pump System 3:Air Distribution System Heat Pump Heating and Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 3:HVAC Fan 3:2 Cooling System 1 'r► Cpl' t � C 12.5' :Heat Pump System 4:Air Distribution System Heat Pump Heating and Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 4:HVAC Fan 4:2 Cooling System 16 :Heat Pump System 5:Air Distribution System Heat Pump Heating and Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 5:HVAC Fan 5:2 Cooling System No No Heat Pump System 3 -hers -cool Heat Pump System 4 HVAC - HEAT PUMPS 01 '` �-� '02 ,, 03 04 05 06 07 08 09 10 Heating j 'W Cooling Zonally Multispeed HERS Name q .Type}}{{HS}aPF/51 -,COP,, p 4C7pplS)EER EERY Controlled Compressor Verification Heat Pump System 1 i r %-SplitHeatPump d #I 9 58000 0 56000 �' 16 � � M2.5. ' No No Heat Pump tem 1 r � 1 -hers -cool ✓ ;;oll 1 'r► Cpl' t � C 12.5' Yes No Heat Pump System Heat Pump System 2 SplitHeatPump 9 58000 56000 16 2 -hers -cool Heat Pump System 3 SplitHeatPump 9 58000 56000 16 12.5 No No Heat Pump System 3 -hers -cool Heat Pump System 4 SplitHeatPump 9.5 36400 36400 17 13.3 No No Heat Pump System 4 -hers -cool Heat Pump System 5 SplitHeatPump 9 58000 56000 16 12.5 No No Heat Pump System 5 -hers -cool Registration Number: 215-N62967016-000000000-0000 Registration Date/Time: 2015-10-2816:40:37 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-10-28 15:25:15 CERTI#E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: New Residence Calculation Date/Time: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xml CF•RF-01 Page 12 of 14 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1 -hers -cool Required 350 Required Required Required Heat Pump System 2 -hers -cool Required 350 Required Required Required Heat Pump System 3 -hers -cool Required 350 Required Required Required Heat Pump System 4 -hers -cool Required 350 Required Required Required Heat Pump System 55 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 DuctsAttic Sealed. and tested 8 Attic None Air Distribution System 2 -hers -dist Not Required Not Required I1 r—,—,� — it Required 6.0 Air Distribution System 3 DuctsAttJ/Sealed #( #;r 4L_ and tested i,� t 8Attic Air Distribution System 4 -hers -dist �' None Air Distribution System Not Required Not Required Not Required g� Air Distribution System 5 -hers -dist Required 6.0 Not Required 3 -hers -dist Not Required Not Required — Af "' Attic. None Air Distribution System Air Distribution S stem 4 y DuctsAttic Sealed and tested +� 8 �' � � 4 -hers -dist � Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 2 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 3 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 4 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 5 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required — Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 201510-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE�OD Project 'PE New Residence Ca culation Daterrime: 15:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Deford-15.xml C*RF-01 Page 13 of 14 HVAC -FAN SYSTEMS 01 02 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 01 02 03 Name " Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan 1 Required 0.58 HVAC Fan 3 -hers -fan - - - _ Required 0.58 HVAC Fan 4-hers-fanRe�quirgd 11111111110 000 A 0.58 HVAC Fan 5 -hers -fan: - Required'"' 0.58 IAQ (Indoor Air Quality) FANS 01 02 '� 03 a. �"'" 'd"*04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 100.42 0.25 Default 0 Required PROJECT NOTES Traditions Country Club Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 201510-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-28 15:25:15 CERTI#E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE POD Project ame: New Residence ation Date/Time: 1.5:23, Wed, Oct 28, 2015 Calculation Description: Title 24 Analysis Input File Name: Bihari Residence-Helton-Def6rd-15.xml CRF -01 Pa e14of14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc.. 2015-10-28 16:40:37 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Businks and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.% ' building design features system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, 3. The or worksheets, calculations, plans and specifications_ submitted tto�the enforcement a-gency�for approval -with this _building perkmit application. Responsible Designer Name: f gg'Re'sponsible Tim Scott 1 /fi'! LL Designer Signature: C# T� Company: i rIt: %j Date Signed: �, .i! V 16.40:37 Scott Design and Title 24, Inc. 2015-10-28 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the ' information. Registration Number: 215-N6296701B-000000000-0000 Registration Date/Time: 201510-28 16:40:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 C Report Generated at: 2015-10-28 15:25:15 1� C RESIDENTIAL MEASURES SUMMARY' RMS -1 Project Name Bihari Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11012812015 Date Project Address Lot 4 Traditions La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floorddition Area 6,292 A n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R38 6,292 New Wall Wood Framed R 21 12,425 New Slab Unheated Slab -on -Grade - no insulation 6,292 Perim = 685' New Demising Wood Framed R 13 2,730 New Door Opaque Door - no insulation 48 New FENESTRATION Orientation Area ft I Total Area: 1,685 Glazing Percentage: 26.8%1New/Altered U -Fac SHGC Overhang Sidefins Average U -Factor: 0.43 Exterior Shades Status Rear(N) 120.0 0.460 0.36 10.0 none Bug Screen New Right (E) 315.0 0.460 0.36 10.0 none Bug Screen New Left (1M 35.3 0.390 0.24 8.0 none Bug Screen New Rear (N) 260.0 0.460 0.36 18.0 none Bug Screen New Right (E) 92.0 0.460 0.36 18.0 none Bug Screen New Front (S) 166.0 0.460 0.36 18.0 none Bug Screen New Front (S) 18.0 0.390 0.24 18.0 none Bug Screen New Rear (N) 84.9 0.390 0.24 none none Bug Screen New Rear (N) 156.0 0.460 0.36 none none Bug Screen New Right (E) 44.3 0.390 0.24 none none Bug Screen New Right (E) 64.0 0.460 0.36 none none Bug Screen New Front (S) 57.6 0.390 0.24 none none Bug Screen New Left (tM 19.8 0.390 0.24 none none Bug Screen New Rear (N) 48.0 0.320 0.24 10.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.00 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.00 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.00 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 1 kit game Ducted Ducted Attic 8.0 New HVAC 2 great bed 3 Ducted Ducted Attic 8.0 New HVAC 3 mster Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Storage Gas 50 0.66 All Pipes Ins New EnemyPro 6.7 by Ene Soft User Number: 6712 Run Code: 2015-10-28715:25:53 ID: Pae 17 of 44 C • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Bihafi Residence Building Type 12 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 6,292 n/a Date 11012812015 # of Units 1 Project Address Lot 4 Traditions La Quinta INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Orientation Area(ft) I Total Area: 1,685 Glazing Percentage: 26.8 New/Altered Average U -Factor: U -Fac SHGC Overhang Sidefins Exterior Shades 0.43 Status Right (E) 18.0 0.240 0.18 6.0 none Bug Screen New Front (S) 18.0 0.240 0.18 6.0 none Bug Screen New Left (IM 144.0 0.320 0.24 10.0 none Bug Screen New Left (Vtoq 24.0 0.460 0.36 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 17.0 SEER Setback New 1 Split Heat Pump 9.00 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 4 media Ducted Ducted Attic 8.0 New HVAC 5 guest Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnemyPro6.7 by EnemySoft User Number., 6712 RunCode: 2015-10-28T15:25:53 /D: Pae 18 of 44 4 2013 .,ow -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may aDDly. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 a . § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §I 10.8(1) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of .§ I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150:0 d . § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device. § 150.0(e)I C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. § I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)]A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R -I6 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § I50.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § I50.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0(m) 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary §I 10.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(6)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13, as applicable. § 150.0(k)I B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §1 50.0(k)]C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §I50.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §I50.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § I50.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § ] 50.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to 110.9, and complies with all other applicable requirements in §150.0(k)2. § I50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § ] 50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 4 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, 140.7 and §141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in $110.9 § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, $130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 13 0.0 c . §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § 110.10 e . §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10 b through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 0 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ihari Residence Date 10/28/2015 System Name HVAC 1 kit game Floor Area 1,471 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 2,087 221 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,000 25,869 2,101 2,322 27,235 Total Output Btuh 58,000 0 Output Btuh/s ft 39.4 1,493 1,041 Cooling System 0 0 Output per System 56,500 9,698 3,225 221 10,687 Total Output Btuh 56,500 0 5,326 0 Total Output Tons 4.7 1,493 1,041 Total Output Btuh/s ft 38.4 Total Output s ft/Ton 312.4 1 38,554 40,005 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 25HCB660-FV4CNB006 37,478 11,883 36,225 Airflow cfmis ft 1.36 Airflow cfm/Ton 424.8 Outside Air % 11.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 37,478 11,883 36,225 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF. Outside Air 221 cfm Supply Fan 2,000 cfm 72 OF d 66 OF 84 OF Heating Coil , A .. A. 83 OF ROOM )" 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/64°F 75/64°F 58/57°F Outside Air Ar 221 cfm Supply Fan Cooling Coil 2,000 cfm 71/62°F 58 / 57 OF 62.7% ROOM 70/62°F EnergyPro 6.7 by EnergySoR User Number: 6712 Run Code: 2015-10-28T15:25:53 ID: Page 23 of 44 r 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ihari Residence Date 10/28/2015 System Name HVAC 2 great bed 3 Floor Area 1,478 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,122 Return Vented Lighting Return Air Ducts Return Fan Ventilation 222 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,000 26,226 2,111 2,825 32,520 Total Output Btuh 58,000 0 Output Btuh/s ft 39.2 1,514 1,243 Cooling System 0 0 Output per System 56,500 9,742 3,230 222 10,715 Total Output Btuh 56,500 0 1,514 1 38,995 5,341 0 Total Output Tons 4.7 1,243 Total Output Btuh/s ft 38.2 Total Output s ft/Ton 313.9 45,722 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 25HCB660-FV4CNB006 37,485 11,896 36,225 Airflow cfm/s ft 1.35 Airflow cfm/Ton 424.8 Outside Air % 11.1 % Total Adjusted System Output 37,485 11,896 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 36,225 Outside Air cfm/s ft 0.15 -Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF Outside Air C+ 222 cfm Supply Fan 2,000 cfm 71 OF 66 OF 83 OF Heating Coil 83 OF ROOM ffi 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/64°F 75/64°F 58/57°F Outside Air 222 cfm Supply Fan Cooling Coil 58 / 57 OF 2,000 cfm 62.7% ROOM 71/62°F 70/62°F EnergyPro 6.7 by EnergySoff User Number: 6712 Run Code: 2015-10-28715:25:53 ID: Page 24 of 44 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ihari Residence Date 10/28/2015 System Name HVAC 3 mster Floor Area 1,352 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,221 Return Vented Lighting Return Air Ducts Return Fan Ventilation 203 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,000 16,152 1,931 1,350 16,919 Total Output Btuh 58,000 0 Output(Bt uh/s ft 42.9 932 647 Cooling System 0 0 Output per System 56,500 8,970 3,159 203 9,862 Total Output Btuh 56,500 0 932 26,987 5,090 0 Total Output Tons 4.7 647 Total Output Btuh/s ft 41.8 Total Output s ft/Ton 287.2 28,075 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 25HCB660-FV4CN8006 37,296 11,667 36,225 Airflow cfmis ft 1.48 Airflow cfm/Ton 424.8 Outside Air % 10.1 % Total Adjusted System Output 37,296 11,667 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 36,225 Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 10-0= Outside Air 203 cfm Supply Fan 2,000 cfm 72 OF 67 OF 84 OF LE Heating Coil 84 OF ROOM 72 OF J = COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/63°F 75/63°F 57/56°F Outside Air Ar 203 cfm Supply Fan Cooling Coil 58 / 56 OF 2,000 cfm 61.4% ROOM 70 / 61 OF 70 / 61 OF EnergyPro 6.7 by EnergySoff User Number: 6712 RunCode: 2015-10-28715:25:53 ID: Page 25 of 44 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ihari Residence Date 10/28/2015 System Name HVAC 4 media Floor Area 884 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan ( Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 415 133 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 36,400 12,789 1,263 1,312 16,462 Total Output Btuh 36,400 0 Output Btuh/s ft 41.2 738 629 Cooling System 0 0 Output perSystem 56,500 5,845 5,060 133 6,422 Total Output Btuh 56,500 0 6,323 0 Total Output Tons 4.7 738 629 Total Output Btuh/s ft 63.9 Total Output s ft/Ton 187.8 20,111 24,143 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 25HNB636-FV4CNB006 44,280 0 22,734 Airflow cfm/s ft 1.36 Airflow cfmfTon 254.9 Outside Air % 11.1 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 44,280 0 22,734 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF Outside Air Ar - 133 cfm Supply Fan 1,200 cfm 72 OF 66 OF 84 OF Heating Coil 84 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/57°F 75/57°F 40/39°F Outside Air 133 cfm Supply Fan Cooling Coil 1,200 cfm 71 /54°F 41 / 39 OF 31.8% ROOM 70/53°F EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-10-28715:25:53 ID: Page 26 of 44 r 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ihari Residence Date 10/28/2015 System Name HVAC 5 guest Floor Area 1,107 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,353 Return Vented Lighting Return Air Ducts Return Fan Ventilation 166 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output er System 58,000 18,858 1,581 1,778 23,444 Total Output Btuh 58,000 0 ' Output Btuh/s ft 52.4 1,089 896 Cooling System 0 0 Output per System 56,500 7,332 2,827 166 8,054 Total Output Btuh 56,500 0 1 1,089 1 28,367 4,408 1 0 Total Output Tons 4.7 896 Total Output Btuh/s ft 51.0 Total Output s ft/Ton 235.1 133,291 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 25HCB660-FV4CNB006 37,394 10,995 36,225 Airflow cfm/s ft 1.81 Airflow cfm/Ton 424.8 Outside Air % 8.3% Total Adjusted System Output 37,394 10,995 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 36,225 Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 166 cfm Supply Fan 2,000 cfm 72 OF 68 OF 85 OF Heating Coil 84 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 74/63°F 74/63°F 56/56°F 0' Outside Air ..� 166 cfm Supply Fan Cooling Coil 57 / 56 OF ' 2,000 cfm 59.5% ROOM 71/61°F 70/61°F EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-10-28715:25:53 ID: Page 27 of 44 • ROOM HEATING PEAK LOADS Project Name Bihari Residence Date 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen and Game Room Floor Area 1,471.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value OT'F 0.0260 X 46 = 0.0690 X 46 = 0.4600 X 46 c 0.3900 X 46 = 0.7300 X 46 = 0.1020 X 0 c X = X X = X X = X X c X = X = X X = X = X X = X = X = X X c X X X X X X = X = another room Page Total 9.00 X 0.266 /60] X 46 Height ACH AT Btu/hr R-38 Roof Attic 1,471.0 1,759 R-21 Wall (W.21.2x6.16) 2,698.7 8,566 Low-E.46.36o 435.0 9,205 Low -E.39.24 f 35.3 633 Slab -On -Grade perim = 125.0 4,198 'R-13 Wall 516.0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,471 X Area 24,360 _ 2,875 TOTAL HOURLY HEAT LOSS FOR ROOM 27,235 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-10-28T15:25:53 ID: Page 33 of 44 ROOM HEATING PEAK LOADS. Project Name Bihari Residence Date 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great room and Bedroom 3 Floor Area 1,478.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X 0.4600 X 0.5000 X 0.3900 X 0.7300 X 0.1020 x x x x x x x x x x x x x x x x x x x x x x x x to another room 9.00 X 0.266 Ceiling Height ACH AT *F X 46 X 46 X 46 X 46 X 46 X 46 X 0 x x x x x x x x x x x x x x x x x x x x x x x x Page Total /60] X AT Btu/hr = 1,768 c 8,760 = 10,961 0 1,104 _ 323 = 6,716 = 0 = = = = = = = = = = = = = = _ = = = = = = 29,632 46 = 2,889 R-38 Roof Attic 1,478.0 R-21 Wall (W.21.2x6.16) 2,760.0 Low -E.46.36 o 518.0 Wood Door 48.0 Low -E.39.24 f 18.0 Slab -On -Grade perim = 200.0 "R-13 Wall 711.0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,478 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 32,520 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-10-28715:25:53 fD: Page 34 of 44 r1 ROOM HEATING PEAK LOADS Project Name Bihari Residence Date 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,352.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 1,352.0 X 0.0260 X 1,415.8 X 0.0690 X 117.2 X 0.3900 X 112.0 X 0.4600 X Perim = 110.0 X 0.7300 X 612.0 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 1,352 X 9.00 X 0.266 Area Ceiling Height ACH OT'F Btu/hr 46 = 1,617 46 = 4,494 46 _ 2,103 46 c 2,370 46 = 3,694 0 c 0 = = = = = = = = = = = = = = = = c = = = = = = Page Total 14,277 /60] X 46 = 2,642 AT R-38 Roof Attic R-21 Wall (W.21.2x6.16) Low -E.39.24 f Low-E.46.36o Slab -On -Grade 'R-13 Wall Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,919 EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-10-28715:25:53 /D: Page 35 of 44 r1 U 17J C ROOM HEATING PEAK LOADS Project Name Bihad Residence Date 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Media Room Floor Area 884.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 884.0 X 2,172.0 X U -Value X X X X X X X X X X X X X x x x x x x x x x x x x x x x x x x AT *F Btu/hr = 1,057 = 6,894 = 2,826 c 397 = 3,559 c 0 = = = = = = = = = = = = = = = = = = = = = = 14,734 46 c 1,728 R-38 Roof Attic 0.0260 46 R-21 Wall (W.21.2x6.16) 0.0690 46 MEDIA Low -E..32.24 o 192.0 X 0.3200 46 MEDIA Low -E..24.18 f 36.0 X X X X 0.2400 46 Slab -On -Grade perim = 106.0 0.7300 46 'R-13 Wall 416.0 0.1020 0 X X X X X X x x x x x x x x x x x x x x x x x x Items shown with an asterisk(') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 884 X Area Ceiling another room 9.00 x 0.266 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 16,462 EnergyPro 6.7 by EnergySoft User Number., 6712 RunCode: 2015-10-28715:25:53 ID: Page 36 of 44 • 1� ROOM HEATING PEAK LOADS Project Name Bihari Residence Date 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Rooms Floor Area 1,107.0 ft- Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F 46 c Btu/hr R-38 Roof Attic 1,107.0 0.0260 1,324 R-21 Wall (W.21.2x6.16) 3,378.6 0.0690 46 = = 10,724 Low -E.46.36 o 132.0 0.4600 46 2,793 Low -E.39.24 f 89.4 0.3900 46 = c = = 1,604 Slab -On -Grade perim = 144.0 0.7300 46 4,836 'R-13 Wall 475.0 0.1020 0 0 = = = = = = = = = = = = = o = = = = = = Page Total /60] X 46 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,107 X Area another room 9.00 X 0.266 Height ACH 21,280 = 2,164 TOTAL HOURLY HEAT LOSS FOR ROOM 23,444 EnergyPro 6.7 by EnergySoft User Number., 6712 Run Code: 2015-10-28715:25:53 /D: Page 37 of 44 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name ' Bihari Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen and Game Room Outdoor Dry Bulb Temperature Floor Area 1,471.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: C ODaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation (IM (N) (E) (S) (Vtq 10/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,471.0 0.0260 56.0 384.0 0.0690 23.0 785.0 0.0690 33.0 200.0 0.0690 26.0 1,329.7 0.0690 33.0 516.01 0.1020 0.0 6.0 16.7 + 0.0 31.0 11.3 16.7 + 0.0 31.0 6.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration lK o 1Lo 1Co 106 f 107 f 108 f 109 f 110f Internal Gain Orientation Shaded Area X X X X X X X X X GLF Unshaded Area X X X X X X X X X GLF = = = = = = = = = 0.0 22.6 + + + + 120.0 22.6 71.1 22.6 18.9 43.9 177.7 22.6 47.3 43.9 6.0 16.7 0.0 31.0 6.0 16.7 + 0.0 31.0 11.3 16.7 + 0.0 31.0 6.0 16.7 + 0.0 31.0 6.0 16.7 + 0.0 31.0 + Page Total 112 OF 78 OF 34 OF Btu/hr 2,142 609 1,787 359 3,028 7, Btulhr 2,707 2,434 6,086 100 100 189 100 100 1 11,8171 4.4 Occupants X 245 Btuh/occ. 1,0 1,471 Floor Area X 0.50 w/sgft = 2,5 Infiltration: 1.064 X 0.94 X 60.67 X 42 = 2,536 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,869 Latent Gain Btu/hr Occupants 4 4 Occupants X 1551 Btuh/occ. = 684 Infiltration: 4.771 X 0.94 X 60.67 X 0.00523 = 1,417 Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 684 I EnerovPro 6.7 by EnerovSoft User Number: 6712 Run Code: 2015-10-28715:25:53 ID: Paae 38 of 44 1 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bihari Residence 1 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great room and Bedroom 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,478.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (W) 1,478.0 X 0.0260 X 56.0 = 2,152 R-21 Wall (W.21.2x6.16) (N) 844.0 X 0.0690 X 23.0 = 1,339 R-21 Wall (W.21.2x6.16) (E) 348.0 X 0.0690 X 33.0 = 792 R-21 Wall (W.21.2x6.16) (S) 992.0 X 0.0690 X 26.0 = 1,780 Wood Door (S) 24.0 X 0.5000 X 26.0 = 312 R-21 Wall (W.21.2x6.16) (149 576.0 X 0.0690 X 33.0 = 1,312 Wood Door (tM 24.0 X 0.5000 X 33.0 = 396 'R-13 Wall 711.0 X 0.1020 X 0.0 = 0 X J X I= Page Total 8,083 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1 M o (N) 0.0 X 22.6 + 200.0 X 22.6 = 4,512 1No (N) 0.0 X 22.6 + 60.0 X 22.6 = 1,354 IDD o (E) 20.0 X 22.6 + 0.0 X 43.9 = 451 i 1 D o (E) 72.0 X 22.6 + 0.0 X 43.9 = 1,624 lA o (S) 36.0 X 22.6 + 0.0 X 22.6 = 812 1B 0 (S) 136.0 X 22.6 + 0.0 X 22.6 = 2,933 105 f (S) 18.0 X 16.7 + 0.0 X 16.8 = 301 X + X = X + I X = Page Total 11,986 Internal Gain Btulhr Occupants 4 4 Occupants X 245 Btuh/occ. = 1,086 Equipment 1,478 Floor Area X 0.50 w/sgft = 2,522 Infiltration: 1.064 X 0.94 X 60.96 X 42 = 2,548 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26,226 Latent Gain Btu/hr Occupants 4 4 Occupants X 155 Btuh/occ. = 687 Infiltration: 4.771 X 0.94 X 60.96 X 0.00523 = 1,424 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 687 EnerqyPro 6.7 by Ene Soft User Number: 6712 RunCode: 2015-10-28715:25:53 ID: Page 39 of 44 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Bihad Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature Floor Area 1,352.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: Ooaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W..21.2x6.16) 'R-13 Wall Orientation I'm (N) (E) (S) (M 10/28/2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,352.0 0.0260 56.0 754.1 0.0690 23.0 11.7 0.0690 33.0 256.0 0.0690 26.0 394.0 0.0690 33.0 612.0 0.1020 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 111 f 112 f 113 f 1Po 115 f 116 f 117f 118 f 1Qo Orientation (N) (N) (N) (N) (N) (N) (N) (E) (E) 112 OF 78 OF 34 OF Btu/hr 1,969 1,197 27 459 897 0 1 4,5481 Shaded Area GLF X 16.7 X 16.7 X 16.7 X 22.6 X 16.7 X 16.7 X 16.7 X 16.7 X 22.6 + + + + + + + + +1 Unshaded Area GLF X 16.7 X 16.7 X 16.7 X 22.6 X 16.7 X 16.7 X 16.7 X 31.0 X 43.9 Page Total = = = = = = = = = 0.0 2.3 0.0 2.3 0.0 2.3 0.0 72.0 0.0 12.0 0.0 18.0 0.0 12.0 0.0 2.3 0.0 20.0 Btu/hr 38 38 38 1,624 200 301 200 71 1 3,3911 Internal Gain Btu/hr Occupants 41 Occupants X 245 Btuh/occ. 994 Equipment 1,352 Floor Area X 0.50 w/sgft = 2,307 Infiltration: 1.064 X 0.94 X 55.76 X 42 = 2,331 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,152 Latent Gain Btu/hr Occupants 41 Occupants X 155 Btuh/occ. = 629 Infiltration: 4,771 X 0.94 X 55.76 X 0.00523 = 1,302 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I EnerovPro 6.7 by EneravSoft User Number. 6712 RunCode: 2015-10-28T15:25:53 ID: Paae 40 of 44 1 r� U RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bihari Residence 1 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,352.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X L X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 119f (E) 0.0X 16.7+ 12.0X 31.0= 371 120 f (E) 0.0 X 16.7 + 12.0 X 31.0 = 371 121f (E) 0.0 X 16.7 + 12.0 X 31.0 = 371 1 R o (E) 0.0 X 22.6 + 20.0 X 43.9 = 879 129 f (S) 0.0 X 16.7 + 24.0 X 16.8 c 402 114 f (VV) 0.0 X 16.7 + 6.0 X 31.0 = 186 X + X = X + X = X +1 X = Page Total 2,581 Internal Gain Btu/hr Occupants 41 Occupants X 2451 Btuh/occ. = 994 Equipment 1,352 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.94 X 55.76 X 42 = 2,331 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,152 Latent Gain Btu/hr Occupants 41 Occupants X 155 Btuh/occ. = 629 Infiltration: 4,771 X 0.94 X 55.76 X 0.00523 = 1,302 Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 629 Energypro 6.7 by Ene Soft User Number., 6712 Run Code: 2015-10-28715:25:53 ID: Page 41 of 44 fl An qP RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bihari Residence 1 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Media Room Outdoor Dry Bulb Temperature 112 °F Floor Area 884.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Ooaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W..21.2x6.16) R-21 Wall (W..21.2x6.16) R-21 Wall (W..21.2x6.16) -R-13 Wall Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 884.01 0.0260 56.0 252.0 0.0690 23.0 682.0 0.0690 33.0 682.0 0.0690 26.0 556.0 0.0690 33.0 416.0 0.1020 0.0 Page Total Items shown with an asterisk (') denote conduction,through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area 1To 123 f 124 f 125 f 126 f 127 f 128 f 1Uo Internal Gain 0.0 X X X X X X X X X 15.3 + + + + + + + + + 48.0 6.0 6.0 6.0 6.0 6.0 6.0 11.5 0.0 11.5 0.0 11.5 0.0 11.5 0.0 11.5 0.0 11.5 0.0 142.2 15.3 1.8 GLF Btu/hr 1,287 400 1,553 1,224 1,2661 0 1 5,7291 X 15.3 = X 22.2 = X 22.2 = X 22.2 = X 11.5 = X 11.5 = X 11.5 c X 29.6 c X = Page Total Btu/hr 735 69 69 69 69 69 69 Z230 Occupants 2.7 Occupants X 245 Btuh/occ. = 650 Equipment 884 Floor Area X 0.50 W/sgft = 1,509 Infiltration: 1.064 X 0.94 X 36.46 X 42 = 1,524 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,786 Latent Gain Occupants 2 7 Occupants X 155 Btuh/occ. Infiltration: 4,771 X 0.94 X 36.46 X 0.00523 = Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Btu/hr = 411 852 411 C • 171 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bihari Residence 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Rooms Outdoor Dry Bulb Temperature 112 OF Floor Area 1,107.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Ooaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) -R-13 Wall Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,107.0 0.0260 56.0 680.0 0.0690 23.0 970.0 0.0690 33.0 766.4 0.0690 26.0 962.2 0.0690 33.0 475.0 0.1020 0.0 16.8 0.0 13.8 X 16.8 0.0 13.8 X 24.0 X I 0.0 43.9 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fpnpstratinn 1 TT o 1Wo 130 f 131 f 1X o 132 f 133 f 134 f 1Vo Oripntatinn (N) (N) (N) (E) (E) (S) (S) (S) W Btu/hr 1,612 1,079 2,209 1,375 2,191 1 8,4651 Shaded Area X X X X X X X X GLF 22.6 + 22.6 + 16.7+ 16.7 + 22.6 + 16.7 + 16.7 + 16.7 + 22.6 + Unshaded Area 20.0 X 64.0 X GLF = = = = = = = = 0.0 22.6 0.0 22.6 0.0x 36.0X 16.7= 0.0 6.0 X X 31.0 0.0 24.0 43.9 0.0 6.0 X 16.8 0.0 13.8 X 16.8 0.0 13.8 X 24.0 X 16.8 0.0 43.9 Page Total 1 Gain its 3.3 Occupants !nt 1,107 Floor Area X 245 Btuh/occ. X 0.50 w/sqft I Infiltration: 1.064 X 0.94 X 45.66 X 42 = Air Sensible CFM ELA AT Btu/hr 451 1,444 601 186 1,054 101 231 231 1,054 Btu/hr- 814 = 1,8891,889 I 1.909 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,8581 Latent Gain Occupants 3 3 Occupants X 155 Btuh/occ. Infiltration: 4,771 x 0.94 x 45.66 x 0.00523 = Air Sensible CFM ELA OW )URLY LATENT HEAT GAIN FOR ROOM 7 by EnergySott User Number: 6712 Run Btu/hr = 515 1,066 515 Am r,1 L-A RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bihari Residence 1 10/28/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Rooms Outdoor Dry Bulb Temperature 112 OF Floor Area 1,107.0 ft-- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 133 f 0.0 X 16.7 + 13.8 X 31.0 = 427 X + X = X + X = X + X = Ix + X = X + X = X + X = X + X = X1 +1 X = Page Total 42 Internal Gain Btu/hr Occupants 33 Occupants X 245 Btuh/occ. = 814 Equipment 1,107 Floor Area X 0.50 w/ggft = 1,889 Infiltration: 1.064 X 0.94 X 45.66 X 42 = 1,909 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,858 Latent Gain Btu/hr Occupants 3 3 Occupants X 155 Btuh/occ. = 515 Infiltration: 4,771 X 0.94 X 45.66 X 0.00523 — 11066 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 515 6 EneMyPro 6.7 by EnemySoft User Number. 6712 RunCode: 2015-10-28715:25:53 ID: Page 44 of 44