04-8005 (SFD) Revision 2 Title 24TITLE 24 REPORT
Title 24 Report for:
Firestone Residence
53-510 Del Gato Drive
La Quinta, Ca
Project Designer:
Mort Firestone
53-510 Del Gato Drive
La Quinta, Ca
Report Prepared By:
Dennis Hurvitz, P.E.
Desert Mechanical Engineers
75401 Painted Desert Dr.
Indian Wells CA 92210
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
,.APPROVED.
009AZ
(760)56 8-9600 1� ViAi0*15:
Job Number:
Date:
6/15/2006
' 4- J Va'",
5t`f4G ' 3O s• ; 1p�
TX V
nuc 5Zlea kall--
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number: User Number: 5769
TABLE OF CONTENTS
1
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
s
U
EnergyPro 4.1 by Energysoft Job Number: User Number: 5769
Certificate Of Compliance : Residential (Part 1 of 4) CF:1 R
Firestone Residenre
6/15/2006
Project Title
Date
53-510 nel mat rive
I a Qijnta
Project Address
Building Permit #
nPSPrt MPchanical FnainPPrs
(760) 568-9600
Documentation Author
Telephone
Plan Check/Date
FneravPro
CompliWrice Method
15
Climate Zone
Field Check/Date
TDV Ener Use
Standard
Proposed
Compliance
(kBtu/sf-yrf
Design
Design
Margin
Space Heating
1.39
0.75
0.64
Space Cooling
55.81
53.34
2.47
Fans
8.38
7.95
0.44
Domestic Hot Water
5.92
5.87
0.06
Pumps
0.00
0.00
0.00
Totals
nt better than Standard:
71.50 67.90
Building Type: [j] Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
❑ Existing + Add/Alt
(W) 270 deg
Natural Gas
Area: 841 ft2 Avg. U: 0.35
Ratio: 19.4% Avg. SHGC: 0.30
BUILDING ZONE INFORMATION
Zone Name Floor Area Volume
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Wall Wnnd 104 0069 R_21 R_0 n n An
Wall Wond 442 0069 R21 R -n 0 270 go
Wall Wood 314 0 069 R_21 13-0 0 An An
Wall Wnnd Wig n n69 X21 'R -n f1 X8.0_ An
Roof Wood 3 063 n 025. _Q2$_ R-0 0 0
wall I Wood 1 0 069 _B_21 R -Q O_ _0 90
Wall Wnnd 174 n n69 _$_21 R- 0_ 270 An
Wall Wnnd 670 n n69 R_21 R -n 0 18() An
Wall Wood 123 0 069 R'1 R-0 0 —90 A()
Roof Wood 1 263 0 025z R-18 R-0.0 —dam
191:117
Total Conditioned Floor Area
Existing Floor Area:
Raised Floor Area:
Slab on Grade Area:
Average Ceiling Height:
Number of Dwelling Units:
Number of Stories:
# of
Units
Thermostat
Zone Type Type
rnndltioned Setback
Sleeping Sleeo gStaL—
4,333 ft2
n/a ft2
0 ft2
4,333 ft2
12.0 ft
1.00
1
Vent
Hgt. Area
—2
at
_2 _n/e
Gains Condition
Y / N Status JA IV Reference Location / Comments
EnergyPro 4.1 by EnergySoft User Number: 5769 Job Number: Page:3 of 7
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Firestone Residence 6/15/2006
Project Title Date
FENESTRATION SURFACES
True Cond.
Area U -Factor' SHGCZ Azm. Tilt Stat. Glazi
Location/
Comments
NFRC n -90_ New Firestone Residence
Window
Left
(N)
16f) 035 NFRC 0_30
2
Window
Front
(W)
7.5 0.350 NFRC 0_30
3
Window
Front
(W)
50.0 0.350 NFRC 0_30
4
Window
Front
(W)
50.0 0.350 NFRC 0.30
5
Window
Front
(W)
50.0 0.350 NFRC 0.30
6
Window
Front
(W)
50.0 0.350 NFRC 0.30
Z
Window
Rear
(E)
40.0 0.350 NFRC 0_30
8
Window
Rear
(E)
40.0 0.350 NFRC 0.30
3
Window
Rear
(E)
40.0 0.350 NFRC 0.30
1Q
Window
Rear
(E)
40.0 0.350 NERC 0.30
11
Window
Rear
(E)
96.0 0.350 NFRC 0_30
12
Window
Rear
(E)
40.0 0.350 NFRC 0_30
13
Window
Rear
(E)
40.0 0-350 NFRQ JIM
14
Window
Right
(S)
36.0 0.350 NFRC 0_30
15
Window
Right
(S)
24.0 0.350 NFRC 0.30
16
Window
Right
(S)
7.5 0.350 NFRC 0_30
17
Window
Right
(S)
7.5 0.350 NFRC 0_30
18
Window
Right
(S)
7.5 0.350 NFRC 0_30
la
Skylight
Left
(N)
7.1 0.390 NFRC 0_29
Location/
Comments
NFRC n -90_ New Firestone Residence
_Living
Area
NFRC 270 90 New Firestone Residence
Living
Area
NFRC 270 90 New Firestone Residence
Living
Area
NFRC 270 90 New Firestone Residence
Living
Area
NFRC 270 90 New Firestone Residence
Living
Area
NFRC 270 90 New Firestone Residence
Living
Area
NFRC 90 90 New Firestone Residence
Living
Area
NFRC 90 90 New Firestone Residence
Living
Area
NFRC 90 90 New Firestone Residence
Living
Area
NFRC 90 90 New Firestone Residence
Living
Area
NFRC 90 90 New Firestone Residence
Living
Area
NFRC. 90 90 New Firestone Residence
Living
Area
NFRC 90 -Q_ New Firestone Residence
Living
Area
NFRC 180 90 New Firestone Residence
Living
Area
NFRC 180 90 New Firestone Residence
Living
Area
NFRC 180 90 New Firestone Residence
Living
Area
NFRC: 180 90 New Firestone Residence
Living
Area
NFRC 180 90 New Firestone Residence
Living
Area
NFRC 0 0 New Velux Comfort+(74) Lowe2/Arg_
Living
Area
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING
Inside
Cond. R -Val. JA IV Reference
Condition
Status
Window Overhang Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
_
0.76
17
Bug Screen
0.76
18
Bug Screen
0.76
19
None
1.00
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat
Type (sf) (in.) Cap.
Inside
Cond. R -Val. JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Type Length R -Val.
Insulation
Location JA IV Reference
Condition
Status
Location/
Comments
Run Initiation Time: 06/13/06 16:26:55 Run Code: 1150241215
EnergyPro 4.1 by EnergySoft User Number: 5769 Job Number: Page:4 of 7
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Firestone Residence 6/15/2006
Project Title Date
FENESTRATION SURFACES
# Type Area
U-Factorl SHGCZ
True
Azm. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
2Q
Window
Left
(N)
_ 270 035 NERC __Q M NFRC 0 _.Q New Firectnn . R .cid -n .-
Master Bedrnom
21
Window
Left
(N)
27.0
0.350 NFRC 0.30 NFRC
0 90 New
Firestone Residence
Master Bedroom
22
Window
Left
(N)
15.0
0.350 NFRC 0.30 NFRC
0 90 New
Firestone Residence
Master Bedroom
23
Window
Front
(W)
36.0
0.350 NFRC 0.30 NFRC
270 90 New
Firestone Residence
Master Bedroom
24
Window
Rear
(E)
40.0
0.350 NFRC 0_30 NFRC
90 90 New
Firestone Residence
Master Bedroom
25
Window
Rear
(E)
27.0
0.350 NFRC 0.30 NFRC
90 90 New
Firestone Residence
Master Bedroom
1. Indicate source either from NFRC or Table 116A.
2. Indicate source either from NFRC or Table 1166.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt.
20 Bug Screen 0.76
21 Bug Screen 0.76
22 Bug Screen 0.76
23 Bug Screen 0.76
24 Bug Screen 0.76
25 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Type
Area Thick. Heat Inside
(sq (in.) Cap. Cond. R -Val. JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Type
Insulation
Length R -Val. Location JA IV Reference
Condition
Status
Location/
Comments
EnergyPro 4.1 by EnergySoft User Number: 5769 Job Number: Page:5 of 7
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
Firestone Residence
Duct Condition
Ducts
Location Heating Cooling Location
R -Value Status
6/15/2006
Project Title
4.2 New
Yes
Master Bedroom Ducted Ducted Outdoors
Date
Yes
HVAC SYSTEMS
71 •
New 0.80
2.44% 0.0
Heating
Minimum
Cooling
Minimum
Condition Thermostat
Location
Type
Eff
Type
Eff
Status Type
Living Area
Central Furnace
93% AFUE
Split Air Conditioner
12.0 SEER
New Setback
Master Bedroom
Central Furnace
93% AFUE
Split Air Conditioner
12.0 SEER
New Setback
HVAC DISTRIBUTION
Duct
Duct Condition
Ducts
Location Heating Cooling Location
R -Value Status
Tested?
Living Area Ducted Ducted Outdoors
4.2 New
Yes
Master Bedroom Ducted Ducted Outdoors
4.2 New
Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated l
Tank
Energy
Standbyl Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Loss R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE 1
(%) Ext.
A O Smith Water Products FCG 75 Large Gas All Pipes Ins 1 75,100
71 •
New 0.80
2.44% 0.0
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Documentation Author
Title/Firm: Mort Firestone
Address: 53-510 Del Gato Drive
La Quinta Ca
Telephone:
�. Lic. #:
-- •J��IS-Ol
(ignature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
User Number: 5769
Name: Dennis Hurvitz. P.E.
Title/Firm: Desert Mechanical Engineers
Address: 75401 Painted Desert Dr.
(signature/stamp) (date)
Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R
Firestone Residence 6/15/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
adequacy of the special justification and documentation submitted. IPlan Field
The DHW System "A O Smith Water Products FCG 75 (Q) (L)" is a Large Gas water heater with Pilot Loss = 0 btuh.
IThe HVAC System "Master Bedroom" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approvea MtKS proviaer using utu approvea testing anwor venncation metnoos ana must oe reportea on ine W-411
installation certificate.
Plan
Field
The HVAC System "Living Area" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -
4R.
The HVAC System "Living Area" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The HVAC System "Master Bedroom" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the
CF -4R.
The HVAC System "Master Bedroom" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
I EnerovPro 4.1 by EneravSoft User Number: 5769 Job Number: Paoe:7 of 7 1