BRES2015-0141 Title 24BUILDING ENERGY ANALYSIS REPORT
Will
�..
4
PROJECT.
. Kmsel Residen�
53750 Del Gato, Traditions Golf Club 7/tol -(P
_La Quinta, CA 92253
' Project Designer:
Helton, DeFord & Ass tes
17411 Irvine Blvd. uite O (,/F
..{. .
Tustin, CA 780 CITY OF LA QUANTA r
(909) 957 550
:SUILDING & SAFETY DEPT. •
:APPROVED
FOR CONSTRUCTION;
Report Prepared y;..
10
Tim Scott
:.-
Scott Design and Titl 24, Inc
77085 Michigan DO ,
Palm Desert, CA 92211
(760) 200-4780
RECF
�s. APR 17 ZOLD {+
- tf NTA
Job Number:. CIiY O�'� E `OPMENT
�I; • • COMMUNIT(" DEVE
Date:
4/12/2015 "
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Buildinc Energy Efficiency Standards.
fa 4 This program developed by EnergySoft, LLC — www.energysoft.com. r
EnergyPro 6.5 by EnergySoft User Number: 6712 /D:
CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xmi
CF10F-01
Page 1 of 12
GENERAL INFORMATION
01
Project Name Kinsel Res
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
02
Calculation Description Title 24 Analysis
�x
03
Project Location 53750 Del Gato, Traditions Golf Club
bV ENERGY USE SUMMARY
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version
BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version
EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 160
12
Project Scope Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FTZ) 5349
15 Ate
Number of Zones
4
16
Slab Area (FTZ) 5349
17,�t(
Number of Stories
1
18
Addition Cond. Floor Area N/A
��9'9,
Natural Gas Available
Yes
20
Addition Slab Area (FTZ) N/A
�21
Glazing Percentage (%)
26.8%
&W
COMPLIANCE RESULTS
01 Building Complies with Computer Performance Aft;�
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown%elow
Aw
�x
bV ENERGY USE SUMMARY
04
05���
06
07
08
Energy Use
(kTDV/ft2-yr)
Standard
(Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
W 3.38
4.53
-1.15
-34.0%
Space Cooling
I41bP 89.16
87.72
1.44
1.6%
IAQ Ventilation
�� 1.26
1.26
0.00
0.0%
Water Heating
4.80
4.63
0.17
3.5%
Photovoltaic Offset
,� —
0.00
0.00
—
Compliance Energy Total
V 98.60
98.14
0.46
0.5%
�4
11
Registration Number:
CA Building Energy Efficiency Standa ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-02272015-710
HERS Provider:
Report Generated at: 2015-04-12 17:48:29
CERTIFIO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE CIOD
Project Name: Kinsel Res Ca culation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
CF1*F-01
Page 2of12
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
01
• High Quality Insulation Installation (QII)
03
• IAQ mechanical ventilation
05
Cooling System Verifications:
07
• Minimum Airflow,
Conditioned Floor Af a (ft2)
• Verified EER
Number of Bedrooms
• Verified SEER
Number of Ventilation
Cooling Systems
• Refrigerant Charge
Kinsel Res
• Fan Efficacy Watts/CFM
1
HVAC Distribution System Verifications:
4
• Duct Sealing
Verified in
1
• low -leakage ducts located entirety conditioned space
Domestic Hot Water System Verifications:
-- None —
ENERGY DESIGN RATING °A�
This is the sum of the annual TDV energy consumption for energy use components in�clluded in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part. -6 as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. �
Reference EnergyyUse Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)' 135.26r 134.80 0.46 0.3%
includes calculated Appliances and Miscellaneous Energy Use (AMEpf�
AALF_
BUILDING - FEATURES INFORMATION %50
01
02 v
03
04
05
06
07
Project Name
Conditioned Floor Af a (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Kinsel Res
5349*W
1
12
4
0
1
°!
Registration Number:. Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:29
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF -*F-01
Page 3 of 12
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
HVAC 11
1061
11.5
DHW Sys 1
Window & Door Area (ft2)
Bedrooms 2 & 3
Conditioned
HVAC 22
687
10
DHW Sys 1
310
Living Zone
Conditioned
HVAC 3 & 43
2660
11.3
DHW Sys 1
Front
Casita
Conditioned
HVAC 54
941
9.4
DHW Sys 1
260
1..
OPAQUE SURFACES
A"%
01
02
03
04
05
06
07
08
Name
Zone
Construction ,�ir.� Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
70d Wall
Master Suite
R-21 Wall (W.19.2x6.116)
70
Right
310
90
160d Wall
Master Suite
R-21 Wall (W.19.2x6 16)
160
Front
260
8
90
250d Wall
Master Suite
R-21 Wall (W.119�.2x6.16)
260
- specify -
470
84
90
340d Wall
Master Suite
R-21 Wall (W,49.2x6.16)
340
Back
264
112.2
90
R-38 Roof
Master Suite
R-38 Rooff(R.38.2x14.16)
1061
70d Wall 2
Bedrooms 2 & 3
R -21W all (W.19.2x6.16)
70
Right
390
88
90
160d Wall 2
Bedrooms 2 & 3
R-2:1AWall (W.19.2x6.16)
160
Front
15
90
340d Wall 2
Bedrooms 2 & 3
%-21 Wall (W.19.24.16)
340
Back
15
90
R-38 Roof 2
Bedrooms 2 & 3
a!!�(R-38 Roof(R.38.2x14.16)
687
70d Wall 3
Living Zone
4 R-21 Wall (W. 1 9.2x6.16)
70
Right
710
45.5
90
160d Wall 3
Living Zone
46 R-21 Wall (W19.2x6.16)
160
Front
735
219.6
90
250d Wall 2
Living Zone �, R-21 Wall (W.19.24.16)
260
specify -
960
353
90
340d Wall 3
Living Zone �
R-21 Wall (W.19.24.16)
340
Back
785
310
90
R-38 Roof 3
Living Zone ®`
R-38 Roof(R.38.2x14.16)
2660
70d Wall 4
Casita
R-21 Wall (W.19.24.16)
70
Right
402
72
90
160d Wall 4
Ca a
R-21 Wall (W. 1 9.2x6.16)
160
Front
189
33
90
250d Wall 3^asita
R-21 Wall (W.19.24.16)
260
- specify -
402
52
90
340d Wall 4
R-38 Roof 4
'!�Casita
Casita
R-21 Wall (W.19.2x6.16)
R-38 Roof(R.38.2x14.16)
340
Back
210
941
104
90
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:29
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xmi
CORF-01
Page 4 of 12
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Ventilated
0
0.1
0.85
Yes
No
Attic Bedrooms 2 & 3
Attic RoofBedrooms 2 & 3
Ventilated
0
0.1
0.85
Yes
No
Attic Living Zone
Attic RoofLiving Zone
Ventilated
0
0.1
0.85
Yes
No
Attic Casita
Attic RoofCasita
Ventilated
0
0.1
0.85
Yes
No
• 0
Registration Number: 410
CA
Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 ` Report Generated at: 2015-04-12 17:48:29
CERTIFIS OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista -H DA -1 5.xml
CF10F-01
Page 5of12
WINDOWS
01
02
03
04 05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft) Height (ft)
Multipli
er
Area
(ft)
U -factor
SHGC
Exterior Shading
102
Window
160d Wall (Front -160)
- -
1
8.0
0.45
0.19
Insect Screen (default)
1 E
Window
250d Wall (- specify --260)
- -
1
24.0
0.29
0.21
Insect Screen (default)
103
Window
250d Wall (- specify -260)
- -
1
36.0
0.45
0.19
Insect Screen (default)
104
Window
250d Wall (- specify -260)
- -
1
12.0
0.45
0.19
Insect Screen (default)
105
Window
250d Wall (- specify -260)
- -
1
6.0
0.45
0.19
Insect Screen (default)
106
Window
250d Wall (- specify -260)
- �`� --
1
6.0
0.45
0.19
Insect Screen (default)
1 F
Window
340d Wall (Back -340)
1F2�6> 8.0
1
96.0
0.50
0.21
Insect Screen (default)
107
Window
340d Wall (Back -340)A,=
-
1
16.2
0.45
0.19
Insect Screen (default)
110
Window
70d Wall 2 (Right -70)
mer- -
1
36.0
0.45
0.19
Insect Screen (default)
111
Window
70d Wall 2 (Right -70)
1
8.0
0.45
0.19
Insect Screen (default)
112
Window
70d Wall 2 (Right -70) r
- -
1
8.0
0.45
0.19
Insect Screen (default)
113
Window
70d Wall 2 (Right -70) ��
- -
1
36.0
0.45
0.19
Insect Screen (default)
1J
Window
70d Wall 3 (Right -70)
- -
1
24.0
0.29
0.21
Insect Screen (default)
109
Window
70d Wall 3 (Right -70) ���
-- -
1
8.0
0.45
0.19
Insect Screen (default)
114
Window
70d Wall 3 (Right -70)
- -
1
13.5
0.45
0.19
Insect Screen (default)
100
Window
160d Wall 3 (Front-16py
2.0 8.0
1
16.0
0.45
0.19
Insect Screen (default)
1A
Window
160d Wall 3 (Fronw-§0)
4.0 8.0
1
32.0
0.95
0.49
Insect Screen (default)
101
Window
160d Wall 3 (Fiont=160)
2.0 8.0
1
16.0
0.45
0.19
Insect Screen (default)
1C
Window
160d Wall:�(Front-160)
- -
1
101.6
0.50
0.21
Insect Screen (default)
200
Window
160d Wa11C,'3;(Front-160)
- -
1
6.0
0.45
0.19
Insect Screen (default)
201
Window
160d(�13 (Front -160)
- -
1
6.0
0.45
0.19
Insect Screen (default)
202
Window
1664 Wall 3 (Front -160)
-- -
1
6.0
0.45
0.19
Insect Screen (default)
203
Window
161A Wall 3 (Front -160)
- -
1
0.0
0.49
u.'19
lht6ct Screen (default)
204
Window1"60d
Wall 3 (Front -160)
- --
1
6.0
0.45
0.19
Insect Screen (default)
1 P
Window
*0250d Wall 2 (- specify -260)
- -
1
72.0
0.50
0.21
Insect Screen (default)
1 Q
WindowNw
250d Wall 2 (- specify -260)
- -
1
72.0
0.50
0.21
Insect Screen (default)
1 R
Window
"1 250d Wall 2 (- specify -260)
-- -
1
75.0
0.50
0.21
Insect Screen (default)
1 B
Window
Q� 250d Wall 2 (- specify -260)
13.0 8.0
1
104.0
0.50
0.21
Insect Screen (default)
108
Window
P 250d Wall 2 (- specify -260)
-- -
1
30.0
0.45
0.19
Insect Screen (default)
Registration Number: ��
CA Building Energy Efficiency Stan�ards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-02272015-710
HERS Provider:
Report Generated at: 2015-04-12 17:48:29
CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE NOOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CFIOF-01
Page 6 of 12
1G
Window
340d Wall 3 (Back -340)
23.0 8.0
1
184.0
0.50
0.21
Insect Screen (default)
11-1
Window
340d Wall 3 (Back -340)
12.0 8.0
1
96.0
0.50
0.21
Insect Screen (default)
205
Window
340d Wall 3 (Back -340)
-- --
1
6.0
0.45
0.19
Insect Screen (default)
206
Window
340d Wall 3 (Back -340)
- -
1
6.0
0.45
0.19
Insect Screen (default)
207
Window
340d Wall 3 (Back -340)
-- -
1
6.0
0.45
0.19
Insect Screen (default)
208
Window
340d Wall 3 (Back -340)
- -
1
6.0
0.45
0.19
Insect Screen (default)
209
Window
340d Wall 3 (Back -340)
- -
1
6.0
0.45
0.19
Insect Screen (default)
is
Window
70d Wall 4 (Right -70)
- -
1
24.0
0.29
0.21
Insect Screen (default)
115
Window
70d Wall 4 (Right -70)
- -
1
48.0
0.45
0.19
Insect Screen (default)
116
Window
160d Wall 4 (Front -160)
A� -
1
30.0
0.45
0.19
Insect Screen (default)
117
Window
160d Wall 4 (Front -160)
-
1
3.0
0.45
0.19
Insect Screen (default)
118
Window
250d Wall 3 (- specify -260)
���"- -
1
8.0
0.45
0.19
Insect Screen (default)
119
Window
250d Wall 3 (- specify -260)
-- -
1
8.0
0.45
0.19
Insect Screen (default)
120
Window
250d Wall 3 (- specify -260)
�� - -
1
36.0
0.45
0.19
Insect Screen (default)
1V
Window
340d Wall 4 (Back -340)`
10.0 8.0
1
80.0
0.50
0.21
Insect Screen (default)
!.1
DOORS
t�
01
•�� 02
03
04
Name
Side of Building
Area (ft)
U -factor
Door
�C% 160d Wall 3
24.0
0.50
Door 2
w �`� 340d Wall 4
24.0
0.50
•$
Registration Number: e� " Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Stank ards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:29
CERTIFI*
OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE M010
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xmi
CF1*F-01
Page of 12
OVERHANGS AND FINS
01
02
03
'4U_4
05
06
07
01
02
03
04
05
06 07
08
09
10
11
12 IT7
14
Ar—@Framing
Overhang
Left Fin
*ei
Right Fin
• Cavity/Frame: no insul. /2x4 Top Chrd
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap HL Depth
Top Up
DistL
Bot Up
Depth
Top Up DistR.
Bot Up
1F
7
0.1
7
7
0 0
0
0
0
0
0 0
0
100
10
0.1
10
10
0 0
0
0
0
0
0 0
0
1A
10
0.1
10
10
0 0
0
0
0
0
0 0
0
101
10
0.1
10
10
0 0#4.1
0
0
0
0
0 0
0
113
14
0.1
14
14
0`
0
0
0
0
0 0
0
1G
14
0.1
14
14
0 ��0
0
0
0
0
0 0
0
1 H
10
0.1
10
10
0 0
0
0
0
0
0 0
0
1 V
8
0.1
8
8
0 SIP0
0 1
0
1 0
0
0 0
0
..may
OPAQUE SURFACE CONSTRUCTIONS 4V
01
02
03
'4U_4
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
R -value
U -value
Assembly Layers
Ar—@Framing
*ei
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofMaster Suite
Attic Roofs
Wood Framed Ceiling
W in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
i�
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2x14.16)
attic)
Wood Framed Ceiliriga>
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
�A
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Fraffie9wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedrooms 2 & 3
Attic Roofs
Woodamed Ceiling
in. O.C.
none
0.644
Roofing. Light Roof (Asphalt Shingle)
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofLiving Zone
Attic Roofs s,
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
�,
Cavity/Frame: no insul. /2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofCasita
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing. Light Roof (Asphalt Shingle)
o
s v,
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Stantla ds - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:29
CERTIF0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JOD
Project Name: Kinsel Res ation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xm1
CF1*F-01
Page 8 of 12
SLAB FLOORS
8*
01
02 03.,E 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/2
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab
Master Suite
1061
127
None
0.8
No
Slab 2
Bedrooms 2 & 3
687
42
None
0.8
No
Stab 3
Living Zone
2660
253
None
0.8
No
Slab 4
Casita
941
138
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required Not Required �� Not Required —
i0l
WATER HEATING SYSTEMS
8*
01
02 03.,E 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/2
DHW Pipe Insulation, All Lines DHW Heater 1 2 .0%
C:7
WATER HEATERS 1*
01
01
02
03 4T
04
05
06
07
08
Recirculation
Central DHW
Name
Tank Exterior
Parallel Piping
Compact Distribution
Point -of Use
Control
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank>Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
.-�
DHW Heater 1
Natural Gas
Small Storage
50
0.72
40000-Btu/hr
0
0
.0
WATER HEATING - HERS VERIFICATION
01
02 w
03
04
05
06
07
��qrr
Recirculation
Central DHW
Name
Pipe Insuli do
Parallel Piping
Compact Distribution
Point -of Use
Control
Distribution
DHW Sys 1 - 1/2
—
—
—
—
—
Registration Number: So
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-02272015-710
HERS Provider:
Report Generated at: 2015-04-12 17:48:29
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 400D
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xmi
CF11OF-01
Page 9 of 12
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cooling Component 1:Heating Component 1:Air
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Distribution System 1:HVAC Fan 1:1
System
.ar
SplitAirCond
13
16
Not Zonal
Cooling Component 2:Heating Component 2:Air
Other Heating and Cooling
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Distribution System 2:HVAC Fan 2:1
System
Cooling Compo
coolnent
Cooling Component 4
q01
SplitAirC I d
A�A
13
Cooling Component 3:Heating Component 3:Air
Other Heating and Cooling
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
Distribution System 3:HVAC Fan 3:1
System
Cooling Component 4:Heating Component 4:Air
Distribution System 4:HVAC Fan 4:1
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
Pz
HVAC - HEATING UNIT TYPES
01
02
01.
&0/2
03
Name
',0 Type
Efficiency
Heating Component 1
CntrlFurn�ace` Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFu nr ace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntP Furnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
dn. &urnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES 4SP
01
02
^ �`� 03 04
05
06
07
Name
System Type
®� Efficiency
EER SEER
Zonally Controlled
Multi -speed
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
if �
�v 13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 2
.ar
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Gaoling CoioNuiient 3
SpIIWIlL:0Ma COv
ts
13
16
Not Zonal
Single Speed
Cooling Compo
coolnent
Cooling Component 4
q01
SplitAirC I d
A�A
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
to
Registration Number: 4�® Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:29
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CFIRF-01
Page 10 of 12
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
Cooling Component 2 -hers -cool
Required
350
Required
Required
Required
Cooling Component 3 -hers -cool
Required
350
Required
Required
Required
Cooling Component 4 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS ..
01
02
03
04iW
05
06
07
08
Name
Duct Leakage
Verification,Wrget
DuceLeakage
(%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Name
Type
Duct Leakage
Insula,_'t`ion R -value
Duct Location
Bypass Duct
HERS Verification
Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required
6.0
Air Distribution System
Air Distribution System 1
DuctslnAll
Sealed and tested
8
Attic
None
1 -hers -dist
Required
Not Required
Not Required
V
—
Air Distribution System 4 -hers -dist
Air Distribution System
Air Distribution System 2
DuctslnAll
Sealed and tested
2� 8
Attic
None
2 -hers -dist
Air Distribution System 3
DuctslnAll
Sealed and tested�
8
Attic
None
Air Distribution System
3 -hers -dist
Air Distribution System 4
DuctslnAll
Sealed and .tested
.V
8
Attic
None
Air Distribution System
4 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION �I
01
02
A X03
04
05
06
07
08
Name
Duct Leakage
Verification,Wrget
DuceLeakage
(%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
�� 6.0
Required
Not, Required
Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Air Distribution System 3 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Air Distribution System 4 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
#0
Registration Number: `, Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Stan�dards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:29
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF*F-01
Page CF*
of 12
HVAC -FAN SYSTEMS
%,
02
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
%,
02
01
02 �`�
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
�y
IAQ Recovery
HVAC Fan 1 -hers -fan
Requi^ed
0.58
HVAC Fan 2 -hers -fan
RW"eQquired
0.58
HVAC Fan 3 -hers -fan
Cequired
0.58
HVAC Fan 4 -hers -fan
'0* Required
0.58
Required
oliiv
IAQ (Indoor Air Quality) FANS
01
02
.^y 03
04
05
06
�y
IAQ Recovery
Dwelling Unit
IAQ CFM
AVID IAQ Watts/CFM
IAQ Fan Type
Effectiveness(%)
HERS Verification
SFam.IAQVentRpt
150.99
�0.25
Default
0
Required
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-02272015-710
HERS Provider:
Report Generated at: 2015-04-12 17:48:29
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF*F-01
Page 12 of 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
4/12/2015
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State ip:
Palm Desert, CA 92211
Phone: �►
(J60) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT6�I
I certify the following under penalty of perjury, under the laws of the State of California: ���
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility fo�th�e building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this CertificateoCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Comp it ance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency- fog approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Jim Deford
Company: v
Date Signed:
Helton, DeFord & Associates
Address: ��
License:
17411 Irvine Blvd., Suite O
City/State/Zip:
Phone:
Tustin, CA 92780 ��
(909) 957-4550
.42 1
Registration Number: ���® Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standaar'ds - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:29
•
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Kinsel Residence
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
4/12/2015
Project Address
53750 Del Gato, Traditions Golf Club La 1
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,349
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Roof Wood Framed Attic
R 38
5,349
New
Wall Wood Framed
R 21
4,636
New
Slab Unheated Slab -on -Grade
- no insulation
5,349 Perim = 560'
New
Demising Wood Framed
- no insulation
1,320
New
Door Opaque Door
- no insulation
48
New
FENESTRATION
Orientation Area ft2
Total Area: 1.433 Glainq Percentage: 26.8%1New/Altered
U -Fac SHGC Overhang Sidefins
Average U -Factor: 0.48
Exterior Shades Status
Front (S) 71.0
0.450
0.19 none
none
Bug Screen New
Left (IM 24.0
0.290
0.21 none
none
Bug Screen New
Left (IM 142.0
0.450
0.19 none
none
Bug Screen New
Rear (N) 96.0
0.500
0.21 7.0
none
Bug Screen New
Rear (N) 46.2
0.450
0.19 none
none
Bug Screen New
Right (E) 157.5
0.450
0.19 none
none
Bug Screen New
Right (E) 48.0
0.290
0.21 none
none
Bug Screen New
Front (S) 32.0
0.450
0.19 10.0
none
Bug Screen New
Front (S) 32.0
0.950
0.49 10.0
none
Bug Screen New
Front (S) 101.6
0.500
0.21 none
none
Bug Screen New
Left (tM 219.0
0.500
0.21 none
none
Bug Screen New
Left (IM 104.0
0.500
0.21 14.0
none
Bug Screen New
Rear (N) 184.0
0.500
0.21 14.0
none
Bug Screen New
Rear (N) 96.0
0.500
0.21 10.0
none
Bug Screen New
HVAC SYSTEMS
Qtv. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
2 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
HVAC 1 Ducted
Ducted
Conditioned
8.0
New
HVAC 2 Ducted
Ducted
Conditioned
8J0
New
HVAC 3 & 4 Ducted
Ducted
Conditioned
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
2 Small Storage Gas
50
0.72
All Pipes Ins
New
EnerqvPro 6.5 by EnerqySoft User Number: 6712
Run Code: 2015-04-12T18:13:43
/D:
Pae 15 of 38
C
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Kinsel Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Additicn/Alteration
Date
411212015
Project Address
53750 Del Gato, Traditions Golf Club La
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area Addition
5,349 n1a
# of its
1
INSULATION
Construction Type
Area
Cavity ffz Special Features Status
FENESTRATION I Total Area: 1.433 Glazing Percentage: 26.8 % New/Altered Aver a U -Factor: 0.48
Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status
Rear (N) 80.0 0.500
0.21 8.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 5 Ducted
Ducted Conditioned 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ene Pro 6.5 by Ene Soft User Number: 6712
RunCode: 2015-04-12718:13:43 ID:
Pae 16 of 38
4
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply, Review the respective code section or more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air I:akage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealec.
§110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(1) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is- specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
§150.0(g)1:
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space si& of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
§ I50.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class li
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§ I50.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoars shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)1 A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening Df the firebox.
§I50.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certifi:d to the Energy Commission.
§I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 B--.u/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in§150.Oh2.
§ I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least fire feet from the outlet of any
dryer vent.
§150.0(1):
Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c).
§150.00)1A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exteric r of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, pipsg buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the regeirements of TABLE 120.3-
A.
§ I50.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for Steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the re uirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitabL for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insu. ation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that de ra&s the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditicned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120'✓ electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the:outside termination and the
§ I50.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher t]ian the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a ca-)acity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Cerification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (o- higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181,1JL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings g -eater than %a inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms 'or air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shaLl not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in caliities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesi,.e duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, masti;s, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building most have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment macitenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above cr painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)l0:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in Ength and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that deet the requirements of
§150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space stall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPF) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling opacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and -diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CrM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissble methods of providing the
Whole Building Ventilation.
` § 150.0(o)lA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with tYe Appliance Efficiency
§ 110.4(a):
Regulations; an on-offswitch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electoc resistance heating.
17-
2013 Low -Rise Residential Mandatory Measures Summary
§1 10.4( :
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will a_low all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.C(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans sl6all be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(.:,). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be mam:211y switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply Wath § I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§I50.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirementE of §130.5; and all other
requirements in '150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor regL irements of § 150.0(k) if. it
§I50.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §=30.4; the EMCS requirements
of §130.5; and all other requirements in §150.0(k)2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements. in §150.0(k)2.
§I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ I50.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dini ig and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lightin; installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high :fficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (1C) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and ,
§I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing Tinction and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimcm provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, § 130.2, §130.4, §140.7 and §=41.0.
§150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated -:)y §I50.0(k)9B or 150.0(k)9D
'110.9,
shall comply with the applicable requirements in §130.0, '130.2, 130.4 140.7 and 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, $130.2, $130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 w -.Us of power as determined
according to § 130.0(c).
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
' '
nonresidential garages in 110.9 130.0, ' 130.1 § 130.4 ' 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single builc.ing equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single built ing equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)1213:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of $110.10 b through §1 10.10 e .
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10 b through §110.10 d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in .my requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less titan 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roofor overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered pErking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§I 10.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zon.: shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point ofthe obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§I 10.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roo= live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zcne to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § i 10.10(b) through § 110.10(c)
shall be provided to the occupant.
§110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§I 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
0
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
insel Residence
Date
4/12/2015
System Name
HVAC 1
Floor Area
1,061
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 615 13,405
Return Vented Lighting 0
Return Air Ducts 194
Return Fan 0
Ventilation o 0
Supply Fan 0
Supply Air Ducts 1 1941
TOTAL SYSTEM LOAD 13,793
COIL HTG.
Latent CFM
1,337 358
0 0
1,337
PEAK
Heating System
Sensible
Output per System 71,000
15,793
Total Output Btuh 71,000
Output Btuh/s ft 66.9
188
Cooling System
0
Output per System 47,000
0
Total Output Btuh 47,000
0
Total Output Tons 3.9
188
Total Output Btuh/s ft 44.3
Total Output s ft/Ton 270.9
16,168
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ANB648/58CVX090 35,280
4,157
71,000
Airflow cfm/s ft
1.51
71,000
I Jan 1 AM
Airflow cfm/Ton 408.5
Outside Air % 0.0%
Total Adjusted System Output 35,280
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
4,157
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Outside Air
0 cfm Supply Fan
1,600 cfm
72 °F
72 OF 114 OF
01
Heating Coil
113 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/61°F
Outside Air
0 cfm
75 / 61• OF
75/61°F 54/53°F
o'
c
Supply Fan Cooling Coil
1,600 cfm
46.0 °i°
_
55 / 53 OF
---~-- --
ROOM
75 / 61 OF
EnergyPro 6.5 by Energ Soft User Number: 6712 Run Code: 2015-04-12T18:13:43 ID:
Page 21 of 38
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Kinsel Residence
Date
4/12/2015
System Name
HVAC 2
Floor Area
687
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 323
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 51,000
7,887
866 106
6,724
Total Output Btuh 51,000
0
Output Btuh/s ft 74.2
114
80
Cooling System
0
0
Output perSystem 24,000
0
0 0
0
Total Output Btuh 24,000
0
114
8,115 866
0
Total Output Tons 2.0
80
Total Output Btuh/s ft 34.9
Total Output s ft/Ton 343.5
6,884
Air System
CFM perSystem
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Carrier 24ANB624/58CVX070 19,762
0
51,000
Airflow cfm/s ft
1.16
51,000
Jan 1 AM
Airflow cfmfron 400.0
Outside Air % 0.0%
Total Adjusted System Output 19,762
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Arg 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Q'
Outside Air
0 cfm Supply Fan
800 cfm
72 OF
-d 91119
72 OF 132 OF
Heating Coil
132 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/60°F 75/60°F 52/51°F
O c
Outside Air c
0 cfm Supply Fan Cooling Coil 52 / 51 OF
800 cfm - - - - - -
41.9 % ROOM
75/60°F 75/60°F
Energ Pro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-0412718:13:43 ID:
Page 22 of 38
4
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
insel Residence
Date
4/12/2015
System Name
HVAC 3 & 4
Floor Area
2,660
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,960
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 71,000
42,196
3,352 1,058
46,564
Total Output Btuh 142,000
0
Output Btuh/s ft 53.4
611
554
Cooling System
0
0
Output per System 47,000
0
0 0
0
Total Output Btuh 94,000
0
611
1 43,417
3,352
0
Total Output Tons 7.8
554
Total Output Btuh/s ft 35.3
Total Output s ft/Ton 339.6
47,672
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
3,200
Carrier 24ANB648/58CVX090 70,095
9,035
142,000
Airflow cfm/s ft 1.20
Airflow cfmfTon i
408.5
Outside Air %
0.0%
Total Adjusted System Output 70,095
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
9,035 142,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Qi
Outside Air
0 cfm Supply Fan
3,200 cfm
72 OF
72 OF 114 OF
Heating Coil
113 ,F
ROOM 11
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/62°F 75/62°F 55/54°F
O c ,
Outside Air Ar
0 cfm Supply Fan Cooling Coil 55 / 54 OF
3,200 cfm ----
46.6 % ROOM
75 / 62 OF 75 / 62 OF
EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015.04-12T18:13:43 ID:
Page 23 of 38
4
.4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
insel Residence
Date
4/12/2015
System Name
HVAC 5
Floor Area
941
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems.
1
COIL
CFM
Total Room Loads 608
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 51,000
13,395
1,186 390
16,429
Total Output Btuh 51,000
0
Output Btuh/s ft 54.2
194
195
Cooling System
0
0
Output perSystem 35,500
0
0 0
0
Total Output Btuh 35,500
0
1,186
0
Total Output Tons 3.0
194
195
Total Output Btuh/s ft 37.7
Total Output s ft/Ton 318.1
1 13,783
16,820
Air System
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Carrier 24ANB736/58CVX070 26,835
2,919
51,000
Airflow cfm/s ft 1.28
Airflow cfm/Ton 405.6
Outside Air %
0.0%
Total Adjusted System Output 26,835
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
2,919
Arg 3 PM
51,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Outside Air O
0 cfm Supply Fan
1,200 cfm
72 OF
72 OF 112 OF
Heating Coil
112 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/61
Outside Air
0 cfm
75 / 61 OF
OF 75/61 OF 54/53°F
c
Supply Fan Cooling Coil 54 / 53 OF
1,200 cfm —
45.7 % ROOM
75 / 61 OF
EnergyPro 6.5 by Energ Soft User Number: 6712 RunCode: 2015-04-12718:13:43 10:
Page 24 of 38
•
:7
•
ROOM LOAD SUMMARY
Project Name Date
Kinsel Residence 4/12/2015
System Name Floor Area
HVAC 1 1,061
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible
Master Suite Master Suite 1 1 1 6151 13,4051 1,337 6151 13,4051 1,3371 3581 15,793
PAGE TOTAL
TOTAL*
615
13,405
1,337
358
15,793
615
13,405
1,337
358
15,793
* Total includes ventilation load for zonal systems.
EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-04-12T18:13:43 ID: PaTe 25 of 38
•
•
•
ROOM LOAD SUMMARY
Project Name Date
Kinse/ Residence 411212015
System Name Floor Area
HVAC 2 687
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible I LatentCFMI Sensible I Latent CFMI Sensible
Bedrooms 2 & 3 Bedrooms 2 & 3 1 1 3231 7,887 866 3231 7,8871 866 1061 6,724,
PAGE TOTAL
TOTAL '
323
7,887
866
106
6,724
323
7,887
866
106
6,724
' Total includes ventilation load for zonal systems.
EnergyPro, 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12718:13:43 ID: Page 26 of 38
•
•
0
ROOM LOAD SUMMARY
Kinsel Residence 4/12/2015
System Name Floor Area
HVAC 3 & 4 2,660
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Living Zone Living/KitchenMall/Lau 1 1,960 42,196 3,352 1,960 42,1961 3,3521 1,0581 46,564
PAGE TOTAL
TOTAL'
1,9601
42,196
3,3521
1,0581
46,5
1,9601
42,196
3,3521
1,0581
46, 564
Total includes ventilation load for zonal systems.
EnergyPro 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12T18:13:43 ID: Page 27 of 38
s
•
•
ROOM LOAD SUMMARY
Project Name Date
Kinsel Residence 4/12/2015
.System Name Floor Area
HVAC 5 941
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name I Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFMSensible
Casita I Casita 1 1 6081 13,3951 1,186 6081 13,3951 1,186 390 16,429
PAGE TOTAL
TOTAL*
11 608
13,395
1,186
390
16,429
608
13,395
1,186
390
16,429
* Total includes ventilation load for zonal systems.
EnergyPro 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12718:13:43 /D: Page 28 of 38
:7
•
•
ROOM HEATING PEAK LOADS
Project Name
Kinsel Residence
Date
4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Floor Area 1,061.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
AT *F Btu/hr
46 = 1,269
46 c 3,491
46 c 1,743
46 c 320
46 c 2,208
46 = 4,265
0 = 0
=
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 13,295
/60] X 46 = 2,497
AT
R-38 Roof(R.38.2x14.16)
1,061.0
X
X
X
0.0260
X
X
X
R-21 Wall (W. 19.2x6.16)
1,099.8
0.0690
Double Metal Tinted -Window
84.2
0.4500
Clad French Door
24.0
X
X
X
0.2900
X
X
X
Double Metal Titned-Patio Door
96.0
0.5000
Slab -On -Grade
perim = 127.0
0.7300
'R-0 Interior Wall
210.0
X
X
X
X
0.3560
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X L X
to another room
11.50 X 0.251
Ceiling Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,061 X
Area
TOTAL HOURLY HEAT LOSS FOR ROOM 15,793
EnergyPro 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12T18:13:43 ID: Page 29 of 38
1J1
CJ
ROOM HEATING PEAK LOADS
Project Name
Kinsel Residence
Date
4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedrooms 2 & 3
Floor Area 687.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
687.0 X
332.0 X
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F Btu/hr
46 = 822
46 = 1,054
46 = 1,822
46 = 1,410
0 = 0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
-
=
=
=
=
=
=
=
=
Fage Total 5,107
/60] X 46 =1,617
AT
R-38 Roof(R.38.2x14.16)
0.0260
R-21 Wall (W 19.2x6.16)
0.0690
Double Metal Tinted -Window
88.0
X
0.4500
Slab -On -Grade
perim = 42.0
X
X
X
0.7300
"R-0 Interior Wall
390.0
0.3560
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to
X 687 X
Area Ceiling
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
another room
10.00 X 0.288
Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 6, 724
EnergyPro 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12718:13:43 ID: Page.30 of 38
0
i
C
ROOM HEATING PEAK LOADS
Project Name
Kinsel Residence
Date
4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living/Kitchen/HalULau
Floor Area 2, 660.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 OF
Conduction
Area U -Value
2,660.0 X 0.0260 X
2,261.9 X 0.0690 X
24.0 X 0.2900 X
143.5 X 0.4500 X
32.0 X 0.9500 X
704.6 X 0.5000 X
24.0 X 0.5000 X
pen .m = 253.0 X 0.7300 X
600.0 X 0.3560 X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X L X
through an interior surface to another room
X 2,660 X 11.30 X 0.255
Area Ceiling Height ACH
AT
/60]
'F
46 =
46 =
46 =
46 c
46 c
46 c
46 =
46 =
0 =
=
=
=
=
=
=
=
=
o
=
c
=
=
=
c
=
=
=
=
=
Page Total
X' 46
AT
Btu/hr
3,181
7,179
320
2,970
1,398
16,206
552
8,496
0
40,303
c6,261
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
Clad French Door
Double Metal Tinted -Window
Entry Door
Double Metal Titned-Patio Door
Wood Door
Slab -On -Grade
"R-0 Interior Wall
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
46,564
EnergyPro 6.5 by EnergySoft User Number: 6712
RunCode: 2015-04-12T18:13:43
ID:
Page 31 of 38
•
•
ROOM HEATING PEAK LOADS
Project Name
Kinsel Residence
Date
4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 941.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
AT *F
=
=
=
c
=
=
_
=
=
=
=
=
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
941.0
X
X
X
0.0260
X
X
X
46
1,125
R-21 Wall (W.19.2x6.16)
942.0
0.0690
46
2,990
Clad French Door
24.0
0.2900
46
320
Double Metal Tinted -Window
133.0
X
0.4500
X
46
2,753
Double Metal Titned-Patio Door
80.0
X
X
0.5000
X
X
46
1,840
Wood Door
24.0
0.5000
46
552
Slab -On -Grade
perim = 138.0
X
X
X
0.7300
X
X
X
46
4,634
'R-0 Interior Wall
120.0
0.3560
0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 941 X
Area
to another room
9.40 X 0.307
Ceiling Height ACH
Page Total
/60] X
AT
14,215
= 2,215
TOTAL HOURLY HEAT LOSS FOR ROOM 16,429
EnergyPro 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12718:13:43 /D: Page 32 of 38
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Kinsel Residence 4/12/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,061.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF
Oaaaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W..19.2x6.16)
R-21 Wall (W. 19.2x6.16)
-R-0 Interior Wall
Orientation
W
(E)
(S)
(tM
(N)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,061.01
0.0260
56.0
310.0
0.0690
31.2
252.0
0.0690
28.2
386.0
0.0690
32.6
151.8
0.0690
29.0
210.0
0.3560
0.0
0.0
16.1
6.0
26.9
0.0
16.1
6.0
26.9
0.0
17.8
96.0
Page Total
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fanpstratinn
102
lE
103
104
105
106
1F
107
Orientation
Shaded Unshaded
Btu/hr .
1,545
1 4911
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
.X
.X
p(
X
A
{
;{
_{
GLF
=
=
=
=
=
=
=
c
_
0.0
16.1
8.0
18.0
0.0
13.6
24.0
25.6
0.0
16.1
36.0
26.9
0.0
16.1
12.0
26.9
0.0
16.1
6.0
26.9
0.0
16.1
6.0
26.9
0.0
17.8
96.0
24.5
16.1
16.2
22.2
10.0
Page Total
In614
969
323
161
161
2,356
359
Internal Gain Btu/hr
Occupants 3 2 Occupants X 245 Btuh/occ. = 780
Equipment 1,081 Floor Area X 0.50 w/sgft = 1.811
Infiltration: 1.064 X 0.89 X 52.70 X 37 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13.405
Latent Gain Btu/hr
Occupants 3 2 Occupants X 155 Btuh/occ. = 493
Infiltration: 4,771 X 0.89 X 52.70 X 0.00376 = 844
Air Sensible CFM ELA AW
4
I EnergyPro 6.5 by EnergySoft User Number: 6712 RunCode: 2015-04-12718:13:43 ID: Page 33 of 38
CJ
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Kinsel Residence
1 4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedrooms 2 & 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
687.0 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
687.01 X 0.0260
X
77.0 =
1,375
R-21 Wall (W. 19.2x6.16)
(E) 302.0 X 0.0690
X
39.6 =
824
R-21 Wall (W..19.2x6.16)
(S) 15.0 X 0.0690
X
40.2 =
42
R-21 Wall (W. 19.2x6.16)
(N) 15.0 X 0.0690
X
45.0 =
47
'R-0 Interior Wall
390.0 X 0.3560
X
0.0 =
0
X
X
X
X
=
X
X
=
X
X
=
Page Total
2,288
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
110
(E) 0.0 X 18.4 +
36.0
X 30.9 =
1,114
111
(E) 0.0 X 18.4 +
8.0
X 30.9 =
247
112
(E) 0.0 X 18.4 +
8.0
;K 30.9 =
247
113
(E) 0.0 X 18.4 +
36.0
_K 30.9 =
1,114
X +
K =
X +
K =
X +
x =
X +
{ _
X +
X =
Page Total
2.722
Internal Gain
Btu/hr
Occupants
21 Occupants X 245
Btuh/occ.
=L
505
Equipment
687 Floor Area X 0.50
w/sgft
=
1,172
Infiltration: 1.064
X 0.89 X 34.12 X 37 =
1,199
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,887
Latent Gain
Btu/hr
Occupants
21 Occupants X 155
Btuh/occ.
=
319
Infiltration: 4.771
X 0.89 X 34.12 X 0.00376 =
546
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
319
EnergyPro 6.5 by EnerqySoft
User Number: 6712 Run Code: 2015-0412718:13:43 ID:
Page 34 of 38
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Namee
Dat
Kinsel Residence 4/12/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Living/Kitchen/Hall/Lau
Outdoor Dry Bulb Temperature
112 OF
Floor Area
2,660.0 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
75 °F
Outdoor Daily Ranqe:
34 OF
Opaque Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W.19.2x6.16)
Wood Door
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
'R-0 Interior Wall
Orientation
W
(E)
(S)
(S)
(N)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
0
=
=
2,660.0
0.0260
56.0
664.5
0.0690
31.2
515.4
0.0690
28.2
24.0
0.5000
28.2
607.0
0.0690
32.6
475.0
0.0690
29.0
600.0
0.3560
0.0
42.3
16.0
16.1
0.0
18.0
0.0
17.8
101.6
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
1J
109
114
100
1A
101
1c
200
201
Orientation
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(S)
(S)
Shaded Unshaded
Btu/hr
3,873
1,432
1,004
1
1 8,9611
Area
X
X
X
X
X
X
X
X
X1
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
c
=
=
=
=
=
=
=
-
0.0
13.6
24.0
23.5
0.0
16.1
8.0
25.0
0.0
16.1
13.5
25.0
16.0
16.1
0.0
18.0
32.0
37.2
0.0
42.3
16.0
16.1
0.0
18.0
0.0
17.8
101.6
20.0
0.0
16.1
6.0
18.0
0.0
16.1
6.0
18.0
Page Total
Btu/hr
564
200
338
257
1,190
257
2,029
108
5,
Btulhr
8.0 Occupants X 245 Btuh/occ. = 1.•`
2,660 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.89 X 132.12 X 37 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,196
Latent Gain Btu/hr
Occupants 8 0 Occupants X 155 Btuh/occ. = 1.237
Infiltration: 4,771 X 0.89 X 132.12 X 0.00376 = 2,115
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,237
2015-04-12T18:1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
• Kinse/ Residence 4/12/2015
•
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living/Kitchen/HalULau Outdoor Dry Bulb Temperature 112 OF
Floor Area 2,660. 0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF
Opaque Surfaces
Orientation
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
202
203
204
1P
1Q
1R .
18
108
1G
Oriantatinn
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
16.1
6.0
18.0
0.0
16.1
6.0
18.0
0.0
16.1
6.0
18.0
0.0
17.8
72.0
29.8
0.0
17.8
72.0
29.8
0.0
17.8
75.0
29.8
104.0
17.8
0.0
29.8
0.0
16.1
30.0
26.9
0.0
17.8
184.0
Page Total
Btu/hr
Btulhr
108
108
108
2,146
2,146
2,235
1,850
807
4, 516
14, 025
Internal Gain Btu/hr
Occupants 8.0 Occupants X 245 Btuh/occ. = 1.•
Equipment 2,660 Floor Area X 0.50 W/sgft =
Infiltration: 1.064 X 0.89 X 132.12 X 37 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR,ROOM 42,196
Latent Gain Btu/hr
Occupants 8 0 Occupants X 155 Btuh/occ. = 1,237
Infiltration: 4,771 X 0.89 X 132.12 X 0.00376 = 2,115
Air Sensible CFM ELA AW
RLY LATENT HEAT GAIN FOR ROOM 1,23
I EnemyPro 6.5 by EnemySoft User Number: 6712 Run Code: 2015-04-12T18:13:43 ID: Page 36 of 38
•
C �
J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Kinsel Residence
1 4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living/Kitchen/HalULau
Outdoor Dry Bulb Temperature
112 OF
Floor Area
2,660.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area GLF
Btulhr
1H
(N) 0.0 X 17.8 +
96.0 X
24.5 =
2,356
205
(N) 0.0 X 16.1 +
6.0 X
22.2 =
133
206
(N) 0.0 X 16.1 +
6.0 X
22.2 =
133
207
(N) 0.0 X 16.1 +
6.0 X
22.2 =
133
208
(N) 0.0 X 16.1 +
6.0 X
22.2 =
133
209
(N) 0.0 X 16.1 +
6.0 X
22.2 =
133
X +
X
-
X +
X
=
X +
IXI=
Page Total
3,021
Internal Gain
Btu/hr
Occupants
8 0 Occupants X 245
Btuh/occ_
=
1,955
Equipment
2,660 Floor Area X 0.50
w/sgft
=
4,539
Infiltration: 1.064
X 0.89 X 132.12 X 37 =
4,643
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
42,196
Latent Gain
Btulhr
Occupants
8 0 Occupants X 155
Btuh/occ.
=
1,237
Infiltration: 4,771
X 0.89 X 132.12 X 0.00376 =
2,115
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,237
EneMyPro 6.5 by Ene Soft
User Number: 6712 Run Code: 2015-04-12T18:13:43 ID:
Page 37 of 38
F- -I
L .A
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Kinsel Residence
1 4/12/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area
941.0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(VL9 941.0 X 0.0260
X
56.0 =
1,370
R-21 Wall (W.19.2x6.16)
(E) 330.0 X 0.0690
X
31.2 =
711
R-21 Wall (W.19.2x6.16)
(S) 156.0 X 0.0690
X
28.2 =
304
R-21 Wall (W. 19.2x6.16)
350.0 X 0.0690
X
32.6 =
786
R-21 Wall (W. 19.2x6.16)
(N) 106.0 X 0.0690
X
29.0 =
212
Wood Door
(N) 24.0 X 0.5000
X
29.0 =
348
"R-0 Interior Wall
120.0 X 0.3560
X
0.0 =
0
X
X
=
X J
X I=
Page Total
3,731
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
is
(E) 0.0 X 13.6 +
24.0 X
23.5 =
564
115
(E) 0.0 X 16.1 +
48.0 ° X
25.0 =
1,202
116
(S) 0.0 X 16.1 +
30.0: X
18.0 =
541
117
(S) 0.0 X 16.1 +
3.0 X
18.0 =
54
118
(lM 0.01 X 16.1 +
8.0 X
26.9 c
215
119
(W) 0.0 X 16.1 +
8.Oi X
26.9 =
215
120
0.0 X 16.1 +
36.0; X
26.9 =
969
iv
(N) 0.0 X 17.8 +
80.0; X
24.5 =
1,964
X +
X
=
Page Total
5,724
Internal Gain
Btu/hr
Occupants
2 8 Occupants X 245
Btuh/occ.
=
692
Equipment
941 Floor Area X 0.50
w/sgft
=
1,606
Infiltration: 1.064
X 0.89 X 46.74 X 37 =
1,643
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,395
Latent Gain
Btu/hr
Occupants
2 8 Occupants X 155
Btuh/occ
=
438
Infiltration: 4,771
X 0.89 X 46.74 X 0.00376 =
748
Air Sensible
CFM ELA AIN
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
438
EnerqvPro 6.5 by EnemySoft
User Number: 6712 Run Code: 2015-04-12T18:13.43 /D:
Pa a 38 of 38
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 4*OD
Project Name: Kinsel Res - Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF'&F-01
Page 1 of 12
GENERAL INFORMATION
01
Project Name Kinsel Res
02 This building incorporates features,that require field-testing and/or`venfication;by a certified, HERS rater• under the supervision of a CECapproved HERS provider.
02
Calculation Description Title 24 Analysis
-
V4 o f-, V
03
Project Location 53750 Del Gato, Traditions Golf Club
ENERGY USE SUMMARY
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 160
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1 I
14
Total Cond. Floor Area (FT2)5349
15
Number of Zones 4 L
16
Slab Area (FT2)5349
17
Number of Stories 1
18
Addition Cond. Floor Area NIA
19
Natural Gas Available Yes
20
Addition Slab Area (FTZ) N/A
21
Glazing Percentage (%) 26.8% r --- ---------------- --�
) c:- - 1
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features,that require field-testing and/or`venfication;by a certified, HERS rater• under the supervision of a CECapproved HERS provider.
03 This building incorporates one ormore Special Features show below4 �l�
-
V4 o f-, V
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
3.38
4.53
-1.15
-34.0%
Space Cooling
89.16
87.72
1.44
1.6%
IAQ Ventilation
1.26
1.26
0.00
0.0%
Water Heating
4.80
4.63
0.17
3.5%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
98.60
98.14
0.46
0.5%
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD CF*F-01
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015 Page 2 of 12
Calculation Description: Title 24 Analysis Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xmi
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts located entirety in conditioned space
Domestic Hot Water System Verifications:
• —None —f-ti�1F
ENERGY DESIGN RATING " [ 17
This is the sum of the annual TDV energy consumption for,eAergy use componentswin.cluded in the performance -compliance approach foi, the'Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24; Part'6 (such as domestic `appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)" 1135.26 134.80 0.46 0.3%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05 06 07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Ventilation Number of Water
Number of Zones Cooling Systems Heating Systems
Kinsel Res
5349
1
12
4 0 1
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CFOF-01
Page 3of12
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
HVAC 11
1061
11.5
DHW Sys 1
Gross Area (ft2)
Bedrooms 2 & 3
Conditioned
HVAC 22
687
10
DHW Sys 1
Right
Living Zone
Conditioned
HVAC 3 & 43
2660
11.3
DHW Sys 1
160
Casita
Conditioned
HVAC 54
941
9.4
DHW Sys 1
R-21 Wall (W.19.2x6.16)
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
70d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
70
Right
310
90
160d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
160
Front
260
8
90
250d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
260
- specify -
470
84
90
340d Wall
Master Suite"
i , RY21'Wall (W 19 2x616)
f (03340
)f iBack .4 14, 264
112.2
90
R-38 Roof
Master'Suite
E I R :38 Roof(R'46 2x y4:16
1061
70d Wall 2
Bedrooms'24 3
t R-21 Wall (V11.1 9.2x6.16)}
_ X70 $ �
Rigtif
- R 390
88
90
160d Wall 2
Bedrooms 3
1 1 1:-.. R=2'1 Walf (W.19 2x6.16)N
' 1'60 f
L.-' Front Ifry
15
90
340d Wall 2
Bedrooms 2 & 3
R-21 Wall (W.19.2x6.16)
340
Back
15
90
R-38 Roof 2
Bedrooms 2& 3
R-38 Roof(R.38.2x14.16)
687
70d Wall 3
Living Zone
R-21 Wall (W.19.2x6.16)
70
Right
710
45.5
90
160d Wall 3
Living Zone
R-21 Wall (W.19.24.16)
160
Front
735
219.6
90
250d Wall 2
Living Zone
R-21 Wall (W.19.24.16)
260
- specify -
960
353
90
340d Wall 3
Living Zone
R-21 Wall (W.19.2x6.16)
340
Back
785
310
90
R-38 Roof 3
Living Zone
R-38 Roof(R.38.2x14.16)
2660
70d Wall 4
Casita
R-21 Wall (W.19.24.16)
70
Right
402
72
90
160d Wall 4
Casita
R-21 Wall (W.19.24.16)
160
Front
189
33
90
250d Wall 3
Casita
R-21 Wall (W.19.24.16)
260
- specify -
402
52
90
340d Wall 4
Casita
R-21 Wall (W.19.24.16)
340
Back
210
104
90
R-38 Roof 4
Casita
R-38 Roof(R.38.2x14.16)
941
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE M*D
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF1OF-01
Page 4 of 12
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Ventilated
0
0.1
0.85
Yes
No
Attic Bedrooms 2 & 3
Attic RoofBedrooms 2 & 3
Ventilated
0
0.1
0.85
Yes
No
Attic Living Zone
Attic RoofLiving Zone
Ventilated
0
0.1
0.85
Yes
No
Attic Casita
Attic RoofCasita
Ventilated
0
0.1
0.85
Yes
No
C.00% -�3
01 CLPRTS, nc.,
HEERS PROVIDER
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CFF -01
Page 5 of 12
WINDOWS
01
02
03
04 05
06
07
08
09
10
Name
Type
Multipli
Surface (Orientation -Azimuth) Width (ft) Height (ft) er
Area
(ft)
U -factor
SHGC
Exterior Shading
102
Window
160d Wall (Front -160)
- -
1
8.0
0.45
0.19
Insect Screen (default)
1 E
Window
250d Wall (- specify -260)
- -
1
24.0
0.29
0.21
Insect Screen (default)
103
Window
250d Wall (- specify -260)
- -
1
36.0
0.45
0.19
Insect Screen (default)
104
Window
250d Wall (- specify -260)
- -
1
12.0
0.45
0.19
Insect Screen (default)
105
Window
250d Wall (- specify -260)
- -
1
6.0
0.45
0.19
Insect Screen (default)
.106
Window
250d Wall (- specify -260)
- --
1
6.0
0.45
0.19
Insect Screen (default)
1 F
Window
340d Wall (Back -340)
12.0 8.0
1
96.0
0.50
0.21
Insect Screen (default)
107
Window
340d Wall (Back -340)
- -
1
16.2
0.45
0.19
Insect Screen (default)
110
Window
70d Wall 2 (Right -70)
-- -
1
36.0
0.45
0.19
Insect Screen (default)
111
Window
70d Wall 2 (Right -70)
- -
1
8.0
0.45
0.19
Insect Screen (default)
112
Window
70d Wall 2 (Right -70)
- -
1
8.0
0.45
0.19
Insect Screen (default)
113
Window
70d aall.2.(Rig ht -7.,0) .pow Sam 0 %k ", ,,M I rR -
1
36.0
0.45
0.19
Insect Screen (default)
1J
Window
A 70d.LWall 3 (Right -70) ,
a 44 4, -
Y1VA j 1- 4.0
0.29
0.21
Insect Screen (default)
109
Window
70d'VVall 3 (Right -70) ,L I
� #V
1 t
tw§-O
0.45
0.19
Insect Screen (default)
114
Window
70d Wall 3 (Right -70)) + (
e -i f 7f
r 1"
13.5
0.45
0.19
Insect Screen (default)
100
Window
160d Wall 3 (Front -160)
2.0 8.0
1
16.0
0.45
0.19
Insect Screen (default)
1A
Window
160d Wall 3 (Front -160)
4.0 8.0
1
32.0
0.95
0.49
Insect Screen (default)
101
Window
160d Wall 3 (Front -160)
2.0 8.0
1
16.0
0.45
0.19
Insect Screen (default)
1 C
Window
160d Wall 3 (Front -160)
- --
1
101.6
0.50
0.21
Insect Screen (default)
200
Window
160d Wall 3 (Front -160)
- -
1
6.0
0.45
0.19
Insect Screen (default)
201
Window
160d Wall 3 (Front -160)
- -
1
6.0
0.45
0.19
Insect Screen (default)
202
Window
160d Wall 3 (Front -160)
- -
1
6.0
0.45
0.19
Insect Screen (default)
302
Window
160d Wall 3 (Front -160)
1
6.0
0.45
0.19
Insect Screen (default)
204
Window
160d Wall 3 (Front -160)
- -
1
6.0
0.45
0.19
Insect Screen (default)
1 P
Window
250d Wall 2 (- specify -260)
- -
1
72.0
0.50
0.21
Insect Screen (default)
1Q
Window
250d Wall 2 (- specify -260)
- -
1
72.0
0.50
0.21
Insect Screen (default)
1 R
Window
250d Wali 2 (- specify -260)
- -
1
75.0
0.50
0.21
Insect Screen (default)
1 B
Window
250d Wall 2 (- specify -260)
13.0 8.0
1
104.0
0.50
0.21
Insect Screen (default)
108
Window
250d Wall 2 (- specify -260)
- --
1
30.0
0.45
0.19
Insect Screen (default)
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF1*F-01
Page 6of12
1G
Window
340d Wall 3 (Back -340)
23.0 8.0 1
184.0
0.50
0.21
Insect Screen (default)
1 H
Window
340d Wall 3 (Back -340)
12.0 8.0 1
96.0
0.50
0.21
Insect Screen (default)
205
Window
340d Wall 3 (Back -340)
-- -- 1
6.0
0.45
0.19
Insect Screen (default)
206
Window
340d Wall 3 (Back -340)
-- - 1
6.0
0.45
0.19
Insect Screen (default)
207
Window
340d Wall 3 (Back -340)
- - 1
6.0
0.45
0.19
Insect Screen (default)
208
Window
340d Wall 3 (Back -340)
--- -- 1
6.0
0.45
.0.19
Insect Screen (default)
209
Window
340d Wall 3 (Back -340)
- - 1
6.0
0.45
0.19
Insect Screen (default)
1S
Window
70d Wall 4 (Right -70)
- - 1
24.0
0.29
0.21
Insect Screen (default)
115
Window
70d Wall 4 (Right -70)
--- - 1
48.0
0.45
0.19
Insect Screen (default)
116
Window
160d Wall 4 (Front -160)
-- - 1
30.0
0.45
0.19
Insect Screen (default)
117
Window
160d Wall 4 (Front -160)
- - 1
3.0
0.45
0.19
Insect Screen (default)
118
Window
250d Wall 3 (- specify -260)
-- - 1
8.0
0.45
0.19
Insect Screen (default)
119
Window
250d Wall 3 (- specify -260)
- - 1
8.0
0.45
0.19
Insect Screen (default)
120
Window
250d Wall 3 (- specify -260)
- - 1
36.0
0.45
0.19
Insect Screen (default)
iv
Window
340d Wall 4 (Back -340)
10.0 8.0 1
80.0
0.50
0.21
Insect Screen (default)
--t=s n .. i .0=* s�
DOORS ✓4 ft 11 ff N I I����3
01 w� ,, U L U 021 U
a � yl
FF
b U'�- 39 03 04
Name 1-4 � � Side`,of Building
V N I
P Area (ft2) U -factor
Door 160d Wall 3�
24.0 0.50
Door 2 340d Wall 4
24.0 0.50
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xm1
CF*F-01
Page 7 of 12
OVERHANGS AND FINS
01
02
03
04
05
06
07
_
01
02
03
04
05
06
07
08
09
10
11
12 13
14
"='
;4 Nz'o V
Cavity/Frame: no insul. /2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Overhang
O.C.
Left Fin
P0:644
Roofing: Light Roof Shingle)
Attic RoofMaster Suite
Right Fin
Woo ,Framed Ceiling—
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
1F
7
0.1
7
7
0
0
0
0
0
0
0 0
0
100
10
0.1
10
10
0
0
0
0
0
0
0 0
0
1A
10
0.1
10
10
0
0
0
0
0
0
0 0
0
101
10
0.1
10
10
0
0
0
0
0
0
0 0
0
1B
14
0.1
14
14
0
0
0
0
0
0
0 0
0
1G
14
0.1
14
14
0
0
0
0
0
0
0 0
0
1H
10
0.1
10
10
0
0
0
0
0
0
0 0
0
1V
8
0.1
8
8
0
0
0
0
0
0
0 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
_
Construction Name
Surface Type
,/f
Constru t( n TypFrami
;N'"-
t
Total Cavity
R -value
Winter Design
U -value
Assembly Layers
-
2x4jop;
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CFOF-01
Page 8 of 12
SLAB FLOORS
01
02 °k
x t X-03 i
it 04'4 -i—
r it b5 k..« x..
r s 06
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab
Master Suite
1061
127
None
0.8
No
Slab 2
Bedrooms 2 & 3
687
42
None
0.8
No
Slab 3
Living Zone
2660
253
None
0.8
No
Slab 4
Casita
941
138
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required Not Required Not Required --
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution,tType t:zt�. x z= Water.Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/2 DHW iFipe Insulation; All Lines I q DHW Heafenl� 2 .0%
'^— i t 'k4 If it 1! X1_ It J1 i% It iJ — IF It it i[
WATER HEATERS t._ _t r- ^ r^r. 0.10 4*1%� *4 .f 0t r-,% V— ,r- . ,_.
01
02 °k
x t X-03 i
it 04'4 -i—
r it b5 k..« x..
r s 06
07
08
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
Tank Exterior
—
—
—
—
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.72
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1-1/2
—
—
—
—
—
—
Registration Number: 215•N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 41oD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF10F-01
Page 9of12
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cooling Component 1:Heating Component 1:Air
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Distribution System 1:HVAC Fan 1:1
System
13
16
Not Zonal
Single Speed
Cooling Component 2:Heating Component 2:Air
Other Heating and Cooling
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Distribution System 2:HVAC Fan 2:1
System
Cooling Component 3
SplitAirCond
13
16
Cooling Component 3:Heating Component 3:Air
Other Heating and Cooling
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
Distribution System 3:HVAC Fan 3:1
System
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 4:Heating Component 4:Air
Other Heating and Cooling
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
Distribution System 4:HVAC Fan 4:1
System
HVAC - HEATING UNIT TYPES
01
02
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
f r _ /CnthFTrnace Fuel -fired central furnace _ _
80 AFUE
Heating Component 3
11 iicntrlFtimace Fuel -fired central;furnace If if 11
80 AFUE
Heating Component 4
`CntrlFumace `-}Fu6f-firid central furnace U V V 1
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 2
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 3
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 4
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Kinsel Res Calculation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xm1
CFISF-01
Page 10 of 12
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
Cooling Component 2 -hers -cool
Required
350
Required
Required
Required
Cooling Component 3 -hers -cool
Required
350
Required
Required
Required
Cooling Component 4 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctSInAlI
Sealed and tested
8
Attic
None
Air Distribution System
1 -hers -dist
Air Distribution System 2
DuctSInAlI
Sealed and tested
8
Attic
None
Air Distribution System
2 -hers -dist
Air Distribution System 3
DuctSInAlI
Sealed and Tested -"'
-f.i
8
Attic
None
Air Distribution System
3 -hers -dist
Air Distribution System 4
DuctslnAll
��
t �) x
Sealed andt, ested�
!
j8 Tg
fE t1
Attic
None
Air Distribution System
4 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION v - --
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Air Distribution System 3 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Air Distribution System 4 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-0412 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD
Project Name: Kinsel Res Ca culation Date/Time: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF&F-01
Page 11 of 12
HVAC -FAN SYSTEMS
01
X02 i�
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
X02 i�
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
HVAC Fan 3 -hers -fan
Required
0.58
HVAC Fan 4 -hers -fan
Required
0.58
ti! .-.,.r ...-+.. r...m .+ .. r
IAQ (Indoor Air Quality) FANS 10 ff 11 ff i" IU 11 k�,
01
X02 i�
03 k 11
sr 1 04: a
S OS
06
Dwelling Unit
IAQ C �""
,IAQ Wa Ills CFMOV
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
150.99
0.25
Default
0
Required
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:36
CERTIFW OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 0 O
Project Name: Kinsel Res Calculation DatefTime: 17:46, Sun, Apr 12, 2015
Calculation Description: Title 24 Analysis Input File Name: Kinsel Res -Traditions -Sun Vista-HDA-15.xml
CF*F-01
Page 12 of 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Ti. c zr
Tim Scott
-5'
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-04-12 18:18:53
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to -the enforcement agency for approval;with,this_building permit application.
Responsible Designer Name: # s Responsible Designer Signature;
I.' L
Tim Scott'�.1tL
Company: +e~
Date Signed: r
2015-04 8:18:53
Scott Design and Title 24, Inc.
1 12
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N0095099A-000000000-0000 Registration Date/Time: 2015-04-12 18:18:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-12 17:48:36