13711 (SFD) Title 24TITLE 24 REPORT FOR..:
D&D1606-
LA qUINTA
PROJECT DESIGNER:
OD CONSTRUCTION
61-960 AVENIQA HERRERA
LA QUINTA, CA'
(619) 771-1561
REPORT PREPARED BY:
R.%rown, CEA R92-93 204
'
KROWN MECHANICAL DESIGN
74-170 HWY 111, SUITE 2
PALM DESERT, CA 92260
(619) 773-2623
Job Number- 94049
Date: 6/6/1994
Certitled Energy Analyst
n000�n
,
The COMPLY 24 computer program has been used to perform the calculations
.summarized in this compliance report, This program has roval and is
authorized by the California Energy Commission for use with both the
Residential arid NonresidentialBuilding Energy Efficiency Standards'
This program developedby Gabel Dodd Associates (510) 428-0803,
e
Table Of Contents for Title 24 Report
--------------------------------
CoverPaae........................................................... 1
Table
of Contents ...................................................
2
Form
CF -1R
Certificate of Compliance: Residential ....................
3
Form
MF -1R
Mandatory Measures Checklist: 'Resi.dential ................
5
Form
C -2R
Computer Method Summary ....................................
7
Form
P -2R
Point System Summary .............. U..iK .....................
10
HVAC
Zone
& Space Loads Summary ......... ..'4.......4..4......4......
11
Form.
CF -6R
Installation Certificate: Residential .....................
14
CERTIFICATE OF COMPLIANCE.: Residential (part.I of 2) CF -1R page 3 of 14
Project Name: D & D 1606 ;Date: 6,/6/1994
Address: '
LA QUINTA ;Building Permit No
Designer: DD CONSTRUCTION ;Checked by / Date
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
GENERAL INFORMATION
Compliance Method: COMPLY 24 version 4.11
Climate Zone: 15
Conditioned Floor Area: 1606 sqft
Building Type: Single Fam Det
Building Front Orientation: 0 deg (N)
Number of Dwelling Units: 1.
Floor Construction Type: Slab on Grade
BUILDING SHELL INSULATION
Component 'U -Value Location/Comments
R-13 Powerwall(2x6.16) 0.060 WHOLE HOUSE
Hollow Metal Door 0.581 WHOLE HOUSE
R=13 Part.(W.13.2x.4.16) 0.085 WHOLE HOUSE
Built-up/Air/R-38/Gypbd 0.024 WHOLE HOUSE
Slab Perimeter w/R-0.0 0.720 WHOLE HOUSE
Slab Perimeter w/R-0.0 0.900 WHOLE HOUSE
FENESTRATION Shading Devices Frame_
Orient. Area U -Val Type Interior Exterior OH SF Type
Front (N) 25.0 0.87 Double Opaque White R1 Standard Bug Scr N N Metal
Front (NE) 1.0.0 0.72 Double Opaque White R1 Standard Bug Scr, N N Metal.
Left (E) 12.0 0.87 Double Opaque White RI Standard Bug Scr N N Metal
Left (SE) 20.0 0.87 Double Opaque White Rl Standard Bug Scr N N Metal
Back (S) 28..0 0.87 Double Opaque White R1 Standard Bug Scr N N Metal
Back (S) 40.0 0,87 Double Opaque White R1 Standard Bug Scr Y N Metal
Back (SW) 12.0 0.87 Double Opaque White R1 Standard Bug Scr N N Metal
Right (W) 36.0 0.87 Double Opaque White R1 Standard Bug Scr N N Metal.
Right (NW) 10.0 0.72 Double Opaque White R1 Standard Bug Scr N N Metal
THERMAL MASS Area Thick
Type. Covering (sf) (in) Location/Description
Concrete, Heavyweight Covered 1426 3.50 Slab on Grade
Concrete, Heavyweight Exposed 18 3.50 Slab on Grade
CERTIFICATE OF COMPLIANCE: Residential (part 2 of 2) CF -1R page 4 of 14
---------------------------------------------------------------------------
Project Name: DZ D 1606 ;Date: 6/6/1994
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
HVAC SYSTEMS Minimum Distrib Type Duct T-Stat
System Type Efficiency and Location RVal Type Location/Comments
furnace 0.800 AFUE Ducts in Attic 4.2 SetBck FAU/CU/CO:IL 1
PackAirCo.nd 9.800 SEER Ducts in Attic 4.2 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R -Val
Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
Std Gas 50 gal or Less DomesticHW 0.780 40000 -0.040 0.0 0
SPECIAL FEATURES/REMARKS
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title 24, Parts 1 & 6 of the Califor-
nia Code of Regulations, and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
(Per Business & Professions Code).
DD CONSTRUCTION
51-960 AVENIDA HERRERA
LA QUINTA CA.
(619) 771-156.1 Lic #: .
Y�W- � eo 4 �,
(signature) d e)
ENFORCEMENT AGENCY
Names
Title:
Agency:
Telephone:
DOCUMENTATION AUTHOR
R.Krown, CEA R92-93 .2.04
KROWN MECHANICAL DESIGN
74-170 HWY 1.11, SUITE 2
PALM, DESERT, CA 92260
(61%) 773-2623
(. ignature) (date)
(signature/stamp) (date)
MANDATORY MEASURES CH-ECKLIST (part 1 of 2) MF -1R page 5 of 14
Project Name: D & D 1606 ;Date.: 6/6/1994
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
--------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to, the Standards must contain
these measures regardless of the compliance approach.used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of' Compliance.. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding, minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE ME'ASUR'ES.
o Sec. 150(a): Minimum R-19 ceiling insulation.
o•Sec. 150(b,): Loose fill insulation manufacturers
labeled R- Va.lue,
o Sec. 150'('c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls). *
o Sec. 150(d): Minimum R-13 raised floor insulation in framed
floors: Minimum R-8 in concrete raised floors. *
o Sec. 150(1); Slab edge insulation - water absorption rate
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec.. 118: Insulation specified or installed meets California
Energy Commission quality standards. Indicate Type & form.
o Sec..
a.
b.
C.
Enforcement
116-1,17: Fenestration Products, Ext Doors & Infil/Exfil Controls
Doors and window's between conditioned and unconditioned
spaces designed to limit air leakage.
Manufactured fenestration products have label w/certified U -Value
Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
o Sec. 150(8): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 150{f): Special infiltration barrier installed to
comply with Sec. 151 meets Commission quality standards.
o Sec. 150(e): Installation of Fireplaces,, Decorative Gas.
Appliances and Gas Logs
1. Masonry and factory -built fireplaces have
a. Closeable metal or glass door
b.,0utside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -IR page 6 of 14
_..
Project.N.ame: D & D 1606 ;Date: 6/6/1994
Documentation. KROWN MECHANICAL DESIGN ;;COMPLY' 24 User 2366
--------------------------------------------------------------------------------------
SPACE CONDITIONING, WATER ,H.EATI'NG AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 11.0-1,3: HVAC equipment,, water heaters, showerheads
and faucets certified by the Commission.
o Sec. 1.50(1): Setback thermostat on all applicable
heating systems.
o Sec. 150(j): Pipe and Tank Insulation
1. Indirect hot.water tanks (eg unfired storage tanks or
backup solar hot water tanks)have insulation blanket
(R-12 or greater) or combined interior/exterio:r i-nsu.l"ation
(R=16 or greate.r)_
2. First 5 feet of pipes closest to water heater tank,,
non -recirculation systems, insulated (R-4 or greater.
3. All buried or exposedpiping insulated 'in recirculation
sections of hot water system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between heating source and, indirect hot
water tank.
o Sec. 150"(m) Ducts and Fans. *
1. Ducts constructed;, installed and sealed to comply with
UMC Sections 10.02 and 1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space -
2. ,Exhaust,systems have backdraf t or automatic dampers.
3. Gravity ventilating systems servi,n,g conditioned space have
either automatic or readily accessible manually operated
dampers.
o. Sec. 114 -Pool and S,pa,Heating Systems and Equipment
1_ System is certifi.ed'.w1th 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At .least 36" pipe between filter a7nd heater for future
solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 115: Gas-fired central furnace, pool heater., spa heater
or household cooking appliance have no continuously
burning pilot light. (Excepti,o:n: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec. 150(k): Lighting 40 lumens/watt o:r greater for
general lighting :in kitchens and rooms with water closets;
and recessed ceiling fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY C -2R page 7 of 14
----------------------------------------------------------------------------------
Project Name: D & D 1606 ;Date: 6/6/1994
i
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
POINT SYSTEM COMPLIANCE SUMMARY
Proposed Design Point Score
Budget Compliance Point Goal
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
BUILDING ZONE INFORMATION
Floor
Zone Name Area
FAU/CU/COIL 1 1606
OPAQUE SURFACES Act
Type Area U -Val Azm Tilt
ZONE NAME = FAU/CU/COIL 1
Wall
138
0.060
0
90
Door
2
0.581
0
90
Wall
15
0.060
45
90
Wall
458
0.060
90
90
Wall
16
0.060
135
90
Wall
255
0.060
180
90
Wall
28
0.060
225
90
Wall
350
0.060
270
90
Wall
15
0.060
315
90
Wall
170
0.085
0
90
Door
2
0.581
0
90
Roof
1606
0.0.24
0
0
2:Points *BUILDING COMPLIES*
0 Points
COMPLY 24
15
1606 sqf t
Single Fam
0 deg
1
1
version 4.11
Det
(N)
Slab on Grade
14454 cuf t
1444 sqf t
1444 sqf t
# of
Volume Units Zone Type
14454 1.00 Conditioned
Vent
TStat Type Hgt Area
Setback 2 n/a
Solar
Gains Form 3 Reference Location/Comments
Yes R-13 Powerwall('2x6.16) WHOLE HOUSE
Yes Hollow Metal Door WHOLE HOUSE
Yes R-13 Powerwall(2x6.16) WHOLE HOUSE
Yes R-13 Powerwal.l(2x6.16) WHOLE HOUSE
Yes R-13 Powerwall(2x6.16) WHOLE HOUSE
Yes R-1.3 Powerwall(2x6.16) WHOLE HOUSE
Yes R-13 Powerwall(2x6.16) WHOLE HOUSE.
Yes R-13 Powerwall(2x6.16) WHOLE HOUSE
Yes R-13 Powerwall(2x6.16) WHOLE HOUSE
Yes R-13 Part.(W.13.2x4.16) WHOLE HOUSE
Yes Hollow Metal Door WHOLE HOUSE
Yes Built-up/A:ir/R-38/Gypbd WHOLE HOUSE
COMPUTER METHOD
------------------------------------------------------------------------------
SUMMARY
C -2R
page 8 of 14
Project Name: D
& D 1.606
;Date:
6/6/1994
Documentation:
KROWN MECHANICAL DESIGN
;COMPLY
24 User 2366
PERIMETER
LOSSES
F2
Type
Length
Factor
ZONE NAME
= FAU/CU/COIL
1.
Covered
165.0
0.72
Exposed
16.5
0.90
FENIESTRATI.ON SURFACES
Insulation
R -Val. Depth
# Type Area Frame Div U -Val
ZONE NAME = FAU/CU/COIL 1
Location/Comments
-------------------------
O in WHOLE HOUSE
0 in WHOLE HOUSE
SC
Act Glass
Azm Tilt Only Location/Comments
1
Wdw
Front (N)
25.0
Metal No
0.87
0 90
0.88
WHOLE
HOUSE
2
Wdw
Front (NE)
10.0
Metal No
0.7.2
45 90
0.88
WHOLE
HOUSE
3
Wdw
Left (E)
12.0
Metal No
0.87
90 90
0.88
WHOLE
HOUSE
4
Wdw
Left (SE)
20.0
Metal No
0.87
135 90
0.88
WHOLE
HOUSE
5
Wdw
Back (S)
1.2.0
Metal No
0.87
180 90
0.88
WHOLE
HOUSE
6
Wdw
Back ( S )
40.0
Metal No
0.87
1.80 90
0.88
WHOLE
HOUSE
7
Wdw
Back (S)
16.0
Metal No
0.87
180 90
0.88
WHOLE
HOUSE
8
Wdw
Back (SW)
12.0
Metal No
0.87
225 90
0.88
WHOLE
HOUSE
9
Wdw
Right (W)
4.0
Metal No
0.87
270 90
0.88
WHOLE
HOUSE
10
Wdw
Right (W)
32.0
Metal No
0.87
270 90
0.88
WHOLE
HOUSE
1.1
Wdw
Right (NW)
10.0
Metal No
0.7.2
315 90
0.88
WHOLE
HOUSE
INTERIOR & EXTERIOR
SHADING
#
Type
Interior
Shade
Type _ ... .
SC
Exterior
Shade
Type
SC
1
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
2
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
3
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
4
Wdw
Opaque
White
Rl-r Shade
0.40
Standard
Bug
Screen
0.87
5
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug.
Screen
0.87
6
Wdw
Opaque
White
Rlr Shade
0.4.0
Standard
Bug
Screen
0.8.7
7
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
8
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
9
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
10
Wdw
Opaque
White.
Rlr Shade
0.40
Standard
Bug
Screen
0.87
11
Wdw
Opaque
White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
COMPUTER METHOD SUMMARY C -'2R page 9 of 14
-------------------------------------------------------------------------------------
Project Name: D & D 1606 ;Date: 6/6/1994
i
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
OVERHANGS/SIDE FINS
--Window-.-
# Type Ht Wd
6 Wdw 6..7 5.0
-- Overhang
Len Ht LExt RExt
----
8..5 0.1 8.5 8,.'5
---Left Fin- ---Right Fin --
Dist Len Ht Dist Len Ht
THERMAL MASS Area Thick. Heat Inside Location
Type (sf) (in) Cap Cond Form 3 Reference R -Val. Comments
ZONE NAME = FAU/CU/COIL 1
Covered Slab 1426 3.50 28 0.98 n/a 2
Exposed Slab 18 3.50 28 0.98 n/a O
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVa.1 TYpe Location/Comments
Furnace 0.800 AFUE Ducts in Attic 4.2 SetBck FAU/CU/COIL 1
PackAirCo.nd 9.800 SEER Ducts in Attic 4.2 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R -Val
Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
Std Gas 50 gal or Less -DomesticHW 0.780 40000 0.04.0 0.0 0
SPECIAL FEATURES/REMARKS
,
POINT SYSTEM SUMMARY 9-2R page lO of 14
---------------------------------------
Name: D & D 16O6 :Date: 6/6/1994
/
Documentation: KROWN MECHANICAL DESIGN /COMPLY 24 User 2366
------------- ------------ ---------------------------------------- _-__-____-_-
BUILDING DATA
Conditioned Floor Area 1606 sqft
Number of
Stories
1
Occupancy Type Single
Fam Det
SCORE CARD
Measure
Points -
---------------
1.
------
Roof Insulation
--------
0"0238
(U -Value)
1
2'
Wall Insulation
0'063O
(U -Value)
-2
3.
Raised Floor Insulation
O'OOUO
(U -Value)
—/
Ja.
Controlled Vent CrawI,spaoe
0.0
(R -Value)
|-)
C>
4'
Blab Edge Insulation.
0'7364
(f2 factor)—'
5.
Infiltration
Standard
O
6°
Glass Heat Loss
0"85
12^0%
O
Sum l-6
-1
7'
Fenestration Heat Gain
SC
Orientation Area % Glass
_______
Open
Eff %
SER
___________ _____
North S!S.O 2'2
____
w 0.77 =
1'7
0.44
2
East 32'0 2.0
x 0.77 =
1.5
0'44
2
South 80.0 5'0
x 0'55
2^7
0.44
O
West 46,0 249
x 0'77
2.2
0'44
2,
Skylight Q.O 0'()
x 0'00
0.0
0.00
O
S.
Interior Thermal Maes
1-65
-2
9.
Exterior Wall Mass
0'00,
O
Sum 7-9
4
10'
HeatingSystem
O
Zonal Control: No
11^
Cooling System
-1
12.
Water Heati.ng
0
---
Point
Total:
2
HVAC ZONE HEATING & COOLI:NG LOAD SUMMARY
--------------------------------------------------------------------------
page 11
of 14
Project Name: D & D 1606
;Date: 6/6/1994
Documentation: KROWN MECHANICAL DESIGN
i
;COMPLY 24 User
2366
HVAC ZONE DESCRIPTION
HVAC Zone Name:
FAU/CU/COIL 1
Heating System Name:
DAY&NIGHT SSOCEV048074.A
Cooling System Name:
System Multipl..i.er:
1
Fan Schedule:
24 Hr Fans STD
Peak Load Method`:
COINCIDENT
Relative Humidity:
50 0
COOLING
SPACES IN THIS ZONE PEAK
HEATING
PEAK SENSIBLE LATENT
WHOLE HOUSE (Jan 1.2am)
26161
(Aug 2pm) 22540
-394
TOTAL SPACE LOAD
26161
'22540
-394
Duct Gains & Losses:
2616
2254
Ventilation: ( 0 CFM)
0
0
0
Return Air Lighting Gain
0
TOTAL SYSTEM LOAD
28777
24794
-394
SYSTEM OUTPUT AT DESIGN CONDITIONS
59200
32592
1.1936
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool, this zone during the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable margin to account for variati.ons in weather
conditions and the pick-up capacity required to bring the zone: to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection shoU.ld note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
^
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 12 of 14
----------------------------------------- ----------------------------------
Project Name: D,& D 1606 :Date: 6/6/1994
Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366
---------------- I
Name:
WHOLE HOUSE
Design Indoor Dry Bulb Temperature: 70 F
Design Outdoor Winter Qry8uIb Temperature: 32 F
Design Temperature Difference: 38 F _
Conduction
Area
U -Value
TD
Btu/hr
--------------------------
R-13 Powerwall(2x6.16)
------
1275'0
w
--------
0.0801
---_
x 38~0
------
2918
R-13 part.(W.13'2x4.16)
170'0
m
0'0848
x 38.0
548
HoIlmW Metal Door
4'0
x
0.5814
w 38'0
88
Double Clear Default(R)
25'0
x
8.8700
x 38.0
827
Double Clear Default(R)
10'0
x
0.7200
x 38.0
274
Double Clear Default(R)
12.0
x
0'8700
x 38.0
397
Double Clear Default(R)
20'0
w
0.8700
x 38'0
661
Double Clear Default(R)
28'0
m
0.8700
x 38.0
926
Double ClearDefault(R)
40.0
x
0^8700
x 38'0
1322
Double Clear Default(R)
12'0
x
0'8700
x 88'0
397
Double Clear Default(R)
36.0
w
0.8700
m 38'0
1,190
Double Clear Default(R)
10'0
w
0'7200
x 38'0
274
Built-up/Air/R-38yGypbd
1606,0
x
0'0238
x 38.0
1452
Slab on Grade
Perim =
165-0
x
42
6848
Slab on Grade
Perim =
16.5
x
42
685
Infiltration: 1'00 x 0.018
x 1806 sf
x 9'0
ft
x 0'75 #C
x 38'0
7361
TOTAL
HOURLY
HEAT
LOSS FOR
SPACE
------
28161
Heating AirFlow: 26161
Btu/hr /
[1'07 x
35
F QeltaT)]
= 697
ofm
-
'
' RESIDENTIAL SPACE COOLING LOAD SUMMARY page 13 of 14
-_--__-____-_----__--_--__------_________----__---___-_-_-__-_------_----_-
Projeob Name: Q & D 1606 /Date: 6/6/1994
/
Documentation- KROWN MECHANICAL DESIGN /COMPLY 24 User 2388
---------------------------------------------------------------------------
Space Name: WHOLE HOUSE
Design Indoor
DryBulb
Temperature:
78 F
Design Outdoor
Summer Dry
Bulb Temperature:
112 F
Design Temperature
Difference-
34 F
~
Conduction
Area
W-ValUe
DETD
Btu/hr
--------------------
R-13 Powerwall(2x6.16)
--_---
1275'0
x
-------
0.0601
w
-__-
27'6
------
21.18
R-13 Part.(W,13.2x4.18)
170'0
w
0.0848
x
27'6
398
Hollow Metal
Door
4.0
w
0.5814
x
27.6
64
Double Clear
beftauIt(R)
25.0
w
0~8700
x
34'0
740
Double Clear
Default(R)
10.0
x
0.7200
x
34'0
245
Double Clear
Default(R)
12.0
m
0.8700
x
34.0 z
355
Double Clear
Default(R)
20-.0
x
0,8700
x
34'0
592
Double Clear
Default(R)
2B^0
x
0.8700
x
34.0
828
Double ClearDefault(R)
40-0
x
0.8700
x
34'0
11B3
Double Clear
Default(R)
12'0
x
0'8700
x
34'0
355
Double Clear
Default[Rl
86-0
x
0.8700
x
34'0
1085
Double Clear
Default(R)
10.0
x
0'7200
x
34'0
245
Built-Vp/Air/R-38/Qypbd
1608'0
x
0'0238
x
48'0
1834
Infiltratioo:�
1'00 x 0.018
w 1606
sf m 9'0 ft
x 0'75 #C
x
34.0
6586
Shaded
Unshaded
Solar Gain
Orient.
Area SGF
Area SGF
Sc
-------------------
Double Clear
Default(R)
__--_-_-_
North [
0.0 w 15
+
25.0 x
161
x 0~34
= 127
Double Clear
Default(R)
Northeast [
0.0 w 15
f
10.0 x
481
w 0'34
= 162
Double Clear
Default(R
East
O'O w 15
+
12'0 x
731
uO.34
= 296
Double Clear
Default(R
Southeast
0.0 x 1�5,
+
20'0 x
621
x 0.34
= 419
Double Clear
Default(R)
South
O'O x 15
+
12.0 x
323
x 0'34
= 130
Double Clear
DefauIt(R)
Sou-th [
40'0 x 15
+
8'0 w
321
x 0'34
= 203
QoubIe Clear
Default(R)
South [
0'0 x 15
+
16.0 x
32]
x 0'34
= 173
Double Clear
Default(R)
Southwest
0'0 x 15
+
12'0 w
621
w 0.34
= 251
Double Clear
Default(R)
West
O'O x 15
+
4'6 x
73]
x 0'34
= 99
Double Clear
Default(R)
West
D'O x 16
f
32.0 x
731
x 0.84
= 789
Double Clear
Default(R)
Northwest [
0'0 m 15
+
10.0 x
481
x 0°34
z 162
Internal Gain
Op Frao'
Area
Heat
Gain
Cpnw'
------------------------
Lightiog
--------
1,00
------
x 1606'0
-____-__-
x
0'200
x
3'413
1098
Equipment
1'00
w 1606.0
u
0.1.00
x
3.413
548
Occupants
1'00
x 1606.0
x
225
/
333
1085
------
TOTAL HOURLY
SENSIBLE HEAT
GAIN FOR
SPACE
22540
Latent Gain
---------------
Op Frac.
--------
Area
Heat
Gain
Conv'
_-__-
Btu/hr
____--
___----__
Equipment
1'{)0
------
x 1806.0
x
--------
0.000
x
3.413 =
#
Occupants
1.00
x 1606,0
x
225
/
333 =
1085
Infiltration:
1.00 m 0'018
x 1806
af w 9'0 ft
x 0.75 AC
x
-7.6 =
-1.357
Cooling #irFlmw:
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE -394
22540 Btu/hr / (1_0.7 /t 23 F QeltaT)] �
914 tfm
INSTALLATION CERTI.FI,.CATE CF -6R page .14 of 14
Project Name: D & D 1606 ;Date: 6/6/1994
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2,366
I, the undersigned, verify that the equipme.n°t .listed in the category above
my signature is the actual equipment installed and that the equipment
meets or exceeds the requirements of the Appliance Efficiency Standards.
In addition., I. :have verified :that the equipment is,equivalent to or more
efficient than the equipment specified on the Certificate of Compliance
submitted to demonstrate compliance with the Energy ;Efficiency Standards
for residential buildings.
HVAC 'SYSTEMS
Heat. Equip
CEC Certified Manuf.
Actual Distrib Type
Duct Heat
Heat
System Type
Make & Model Number
Eff, and Location
RVal Load
Output
Furnace
DAY&NIGHT SSOCEV048074A 0.800 'Ducts in Attic
4.2 28777
59200
Cool. Equip
CEC Certified Manuf.
Actual Distri,b
Type
Duct
System Type
Make & Model. Number
Efficiency and Loca-ti,on
RVal
PackAirCo.nd
9.800 SEER Ducts in,Atti.c
4.2
Signature
Date Name
Water- No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
CEC Cert. Make & Model Distribution Type. Type Sys Factor (,gal) R -Val
Std Gas 50 gal: or Less S.ta�ndard StorGas 1 0.53 .50.0 12.0
A'FU E
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input. Loss R -Val Light
Std Gas 5.0 gal or Less Domesti.cHW 0.180 40000 0.040 0,0 0
FAUCETS & SHOWER,H'EADS:
A11 faucets and showerheads are listed .in the Commissions Directory Of
Certified Faucets And Showe'rheads,.-u,rsu`ant to Title 24, Part 6,
Subc'hapte'r 2, Section 1.11.
Signature Date Name