04-5731 (AR) Title 240 10 1• 0 t TITLE 24 REPORT I Title 24 Report for: Quilling Remodel 52-130 La Quinta , Ca 92253 Project Designer: McFadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Report Prepared By: Micah Combs C.M. Energy Consulting 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 _ 760 -38�T8 F�L A�QUINTA 3144 BUILDING & SAFETY DEPT. 'OJOAPPROVED JV FOR CONSTRU TION ` �i1a Ins DA ABY a �1O) b 0405.00 Date: 6/16/04 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. Ec�ergyPro 3.1 By EnergySoft Job Number. 0405.00 User Number: 1088 �• gz•r3o C 04DOA/ cr �F�Ekory sta/ toC 0 I Oe r- 1 0 0 0 'Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise,residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures ��— 7 whether they are shown elsewhere in the documents or on this checklist only. F7 ►1. l •u I* DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ®'§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. ®`§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does to not apply exterior mass walls). a' § 150(d):. Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ®§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. XX §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ® §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0405.00 Page:1 of 2 P 2 C-^ 10 I Ou li 'Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise.residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ® '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UI -181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 114 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ® §115: Gas fired central fumaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures FX] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumensfwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ® §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumenstwatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 1086 Job Number. 0405.00 Page:2 of 2 n LJ 0 0 (10 F, l� ZJ r. Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Quilling Remodel 6/16/04 Project title Date 52-130 La Quinta Project Aaaress C.M. Energy Consulting (760) 346-8014 Documentation Autnor Telephone Computer Performance 15 Building ermi PlanCheck-7-Date Field ec a e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: Total Conditioned Slab Area: Building Type: (check one or more) ® Single Family Detached A ❑ Single Family Attached ❑ Multi -Family iso 10 19 U i•u 10 3,096 ft2 Average Ceiling Height: 3,096 ft2 ❑ Addition ❑ Existing Building ® Existing Plus Addition Front Orientation: (Southwest) 225 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING SHELL INSULATION Floor Construction Type: FX -1 Slab Floor ❑ Raised Floor 11.6 ft Component Type Frame Type Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof(R.38.2x12.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade Na 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Left (North) 10.0 1.04 0.76 Bug Screen ❑ X❑ ❑ X❑ Left (North) 40.0 0.51 0.40 Bug Screen ❑ X❑ ❑ XX Rear (East) 66.0 0.51 0.53 Bug Screen 1:1 XD El NRear (East) 30.0 0.52 0.48 Bug Screen ❑X❑ ❑ ❑X Rear (East) 174.0 0.49 0.44 Bug Screen ❑ X❑ ❑ ❑X Right (South) 15.0 0.51 0.53 Bug Screen 1:1 X❑ El x0 Rear (East) 53.0 0.99 0.74 Bug Screen ❑ X❑ ❑ XD Rear (East) 91.0 1.04 0.76 Bug Screen ❑ XD ❑ X❑ Rear (East) 81.5 0.72 0.73 Bug Screen ❑ ® ❑ Right (Southeast) 64.0 0.49 0.44 Bug Screen ❑ X❑ ❑ ❑X Right (South) 70.0 0.72 0.73 Bug Screen ❑ N ❑X Front (West) 53.0 0.99 0.T4 Bug Screen ❑ ® ❑ x❑ Run Initiation Time: 06/16/0410:26:33 Run Code: 1087406793 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0405.00 Page:1 of 4 0 0-0 :j u 0 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Quilling Remodel 6/16/04 Project i e Date 52-130 La Quinta Project Aaaress C.M. Energy Consulting (760) 346-8014 ocumen a ion Author Telephone Computer Performance 15 Building ermi Plan Check / Date Reld UneCKDate Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: Total Conditioned Slab Area: Building Type: (check one or more) ® Single Family Detached- Single etachedSingle Family Attached ❑ Multi -Family 3,096 ft2 'Average Ceiling Height: 11.6 ft 3,096 ft2 ❑ Addition ❑ Existing Building ® Existing Plus Addition Front Orientation: (Southwest) 225 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING SHELL INSULATION Component Type FENESTRATION Floor Construction Type: X❑ Slab Floor ❑ Raised Floor Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Front (West) 91.0 1.04 0.76, Bug Screen ❑ x❑ ❑ K Right (South) 100.0 0.87 0.70 Bug Screen ❑ x❑ ❑ x❑ Front (West) 8.0 0.87 0.70 Bug Screen ❑ x❑ ❑X❑ Front (West) 17.5 0.72 0.73 Bug Screen ❑ x❑ ❑ x❑ 1:1 El 1-1 1:1 1:1 1:1 El F-1 ❑ ❑ ❑. ❑ 1:1 El F1 F1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 06/16/0410:26:33 Run Code: 1087406793 EnergyPro 3.1 By EnergySoR User Number. 1088 Job Number. 0405.00 Pagel of 4 • Certificate of Compliance: Residential (Part 2 of 2) CF -1 R 4.2 Quilling Remodel ZONE 1 Split Air Conditioner 6/16/04 Ducts in Attic Project Iitle Setback ZONE 2 a e 11.0 EER HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. 4.2 Setback Distribution Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Equipment Heating P Minimum Type and Duct or Palm Desert, CA 92260 Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 2 Central Furnace 92% AFUE Ducts in Attic 4.2 Setback ZONE 3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 15.8 SEER Ducts in Attic 4.2 Setback ZONE 1 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback ZONE 2 Large Split Air Conditioner 11.0 EER Ducts in Attic 4.2 Setback ZONE 3 . WATER HEATING SYSTEMS Water Heater Water Heater Distribution System Name Type Type Rated 1 Tank Energy Fact! 1 External # in Input Cap. or Recovery Standby Tank Insul. Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN G52 -50T38 -3N Small Gas RecirclTime+Temp 1 35,000 50 0.60 n/a n/a •� 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS Ll Nil existing information impu a into the report was taRen ftom the previous I itle--24 prepared by Tim Scott dated 12/12/97. Please see attached copy of existing CF -1 R and MF -1 R. COMPLIANCE STATEMENT s This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Micah Combs Title/Firm: McFadden/McIntosh Architects Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Address: 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Palm Desert, CA 92260 Telephone: (760) 346-8014 Telephone: (760) 46 14 Lic. #: L—'w 0"X U (signs (date) (signature) (date) Enforc nt Agenc Name: Title/Firm: Address: Telephone: �J signature stamp ate Run Initiation Time: 06/16/0410:26:33 Run Code: 1087406793 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0405.00 Page:3 of 4 s Certificate of Compliance: Residential (Addendum) CF -1 R Quilling Remodel 1 6/16/04 roiect Title Date The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justitication and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 700 sgft Tile in Mortar Interior Mass, 0.75" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 700 sgft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 711 sgft Covered Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 688 sgft Tile in Mortar Interior Mass, 0.75" thick at Zone 2 HIGH MASS Design(see C -2R) -Verify Thermal Mass: 688 sgft Exposed Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 302 sqft Covered Slab Floor, 4.00" thick at Zone 2 HIGH MASS Design(see C-211) - Verity Thermal Mass: 57 sgft Tile in Mortar Interior Mass, 0.75" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 57 sgft Exposed Slab Floor, 3.50" thick at Zone 3 HIGH MASS Design(see C-211) - Verify Thermal Mass: 638 sgft Covered Slab Floor, 4.00" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Run InitiationTime: un o e: 1087406793 �En._rgyP, 3.1 By EnergySoft User Number. 1086 Job Number: 0405.00 PageA of 4 L C)e ra � p= Q of vo � Q 943 0 0 Computer Method Summary (Part 1 of 3) C -2R Quilling Remodel 6/16/04 rotec Tle Date _ "2-130 La Quinta vroject raaaress • C.M. Energy Consulting (760) 346-8014 o� cumenfa on u orTelep ons e Computer Performance 15 Building Pertnit an Ch-i-clU135te --- '-- -- Held Gheck/uate Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Existing+Addition Budget Adjustment Space Heating 3.32 2.85 0.47 Space Cooling 36.42 81.02 -44.59 Domestic Hot Water 9.21 7.87 1.33 Totals .23 +-48—.4-5-- 97.18 91.74 5._44__ Percent better than Standard: 40 Total Conditioned Floor Area: • is Building Type: Single Fam Detached Building Front Orientation: (Southwest) 225 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name ZONE 1 ZONE 2 ONE 3 OPAQUE SURFACES Act. Floor Area Volume 5.6% Ratio F: 2902 / 3096 = 0.937 Budget Adj: 0.937 X (102.49 - 51.04) = 48.23 The budget shown to the left has been Increased using this Budget Adjustment based upon Existing building Information shown on the C-211 which follows this form. Floor Construction Type: ❑ Raised Floor ® Slab Floor Total Fenestration Area: 31.1 % Total Conditioned Volume: 35,757 ft 3 Total Conditioned Slab Area: 3,096 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area 1,411 16,930 0.46 Conditioned Setback 2 n/a 990 11,878 0.32 Conditioned Setback 2 n/a 695 6,950 0.22 Conditioned Setback 2 n/a ___S0fa Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments K7 Computer Method Summary (Part 2 of 3) C -2R uilling Remodel • # 1 2 3 4 5 • 6 7 8 -i- 10 Ti 12 13 • 14 15 16 17 18 19 20 4021 22 23 24 25 26 rQ INTERIOR AND EXTERIOR SHADING Type Window Rear (East) Window Rear (East) Window Rear (East) Window Rear (East) Area 10.0 40.0 22.0 22.0 22.0 30.0 174.0 50 53.0 19.0 19.0 26.5 26.5 64.0 64.0 40.0 53.0 26.5 26.5 19.0 --19.0 17.5 100.0 30.0 8.0 17.5 # Exterior Shade Type SHGC 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 40 5 Bug Screen 0.76 8 Bug Screen 0.76 7- Bug Screen 0.76 V- Bug Screen �T6 9 Bug Screen 0.76 10 Bug Screen 0.76 Tf ug Screen X76 .TZ ug creen --70.7S T3 Bug Screen 90 Single Clear Default (NM) -R ug creen --W.76- T5 ug creen --V.76- 1-6 Bug creen --0.76- 17 Bug Screen 0.76 T8 ug creen -0:76- 1-9 Bug Screen --O.T6- 36 ug creen ---Y76- 37 ug creen �T6 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 a Ll - Factor 1.040 0.510 0.510 0.510 0.510 0.520 0.490 x.00 0.990 1.040 1.040 1.040 1.040 0.720 0.490 0.720 0.990 1.040 1.040 1.040 0.720 6.870 0.720 0.870 0.720 SHGC 0.76 0.40 0.53 0.53 0.53 0.48 0.44 T3 0.74 0.76 0.76 0.76 0.76 0.73 0.44 0.73 0.74 0.76 0.76 0.76 0.76 0.73 0.70 0.73 0.70 0.73 WTA ITS. WE TV Act. Glazing Type Azm. Tilt 0 90 Single Clear Default (NM) 0 90 Sierra Pacific Mtl. Clad 90 90 Sierra Pacific Mtl. Clad 90 90 Sierra Pacific Mtl. Clad 90 90 Sierra Pacific Mtl. Clad 90 90 Sierra Pacific Mtl. Clad 90 90 Sierra Pacific Mtl. Clad 80 90 Sierra Pacific Mtl. Clad 90 90 Single Clear Default (NM) 90 90 Single Clear Default (NM) 90 90 Single Clear Default (NM) 90 90 Single Clear Default (NM) 90 90 Single Clear Default (NM) 90 90 Double Clear Default (Mtl) 135 90 Sierra Pacific Mtl. Clad 180 90 Double Clear Default (Mtl) 270 90 Single Clear Default (NM) 270 90 Single Clear Default (NM) 270 90 Single Clear Default (NM) 270 90 Single Clear Default (NM) 90 Single Clear e u t 90 90 Double Clear Default (Mtl) 180 90 Double Clear Default (Mtl) 180 90 Double Clear Default (Mtl) 270 90 Double Clear Default (Mtl) 270 90 Double Clear Default (Mtl) Left Fin 6/16/04 Location/ Comments ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY _ ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY _ ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY E 2 ONLY _--_- ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY Fin Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 EnergyPro 3.1 By EnerovSoft User Number. 1086 Job Number. 0405.00 Page:2 of 9 HVAC SYSTEMS Heating Equipment Computer Method Summary Distribution Type (Part 3 of 3) C -2R Efficiency Quilling Remodel pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) Central Furnace 80%AFUE Ducts in Attic 6/16/04 80%AFUE ro e e Central Furnace 92%AFUE Ducts in Attic Date' - THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar 700 0.75 24 0.67 n/a 0 ZONE 1 ONLY / Interior Mass Concrete, Heavyweight 700 3.50 28 0.98 n/a 0 _ ZONE 1 ONLY / Slab on Grade Concrete, Heavyweight 711 4.00 28 0.98 n/a 2 ZONE 1 ONLY / Slab on Grade Tile in Mortar 688 0.75 24 0.67 n/a 0 ZONE 2 ONLY / Interior Mass Concrete, Heavyweight 688 3.50 28 0.98 n/a 0 ZONE 2 ONLY / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 35 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 59 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 32 0.76 0.0 0 ZONE 2 ONLY _ • Slab Perimeter 50 0.76 0.0 0 ZONE 2 ONLY Slab Perimeter 20 0.76 0.0 0 ZONE 3 ONLY _ HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) Central Furnace 80%AFUE Ducts in Attic Central Furnace 80%AFUE Ducts in Attic Central Furnace 92%AFUE Ducts in Attic Oydronic Piping Pipe Pipe Insul. j System Name Length Diameter Thick. Cooling Equipment Type (air conditioner, a heat pump, evap. cooling) Split Air Conditioner Split Air Conditioner Large Split Air Conditioner WATER HEATING SYSTEMS Water Heater System Name AMERICAN G52 -50T38 -3N Minimum Duct Efficiency Location (SEER) (attic, etc,) 15.8 SEER Ducts in Attic 14.0 SEER Ducts in Attic 11.0 EER Ducts In Attic Duct Thermostat Location / R -Value Type Comments 4.2 Setback ZONE 1 4.2 Setback ZONE 2 4.2 Setback ZONE 3 Duct Thermostat Location / R -Value Type Comments 4.2 Setback ZONE 1 4.2 Setback ZONE 2 4.2 Setback ZONE 3 Ratedl Tank Water Heater Distribution # in Input - Cap. Type Type Syst. (Btu/hr) (gal) Small Gas Recirc/Time+Temp 1 35,000 Energy Fact? or Recovery Efficiency 50 0.60 1 Tank Insul. Standby R -Value Loss (%) Ext. n/a n/a 1 For small gas storage (rated Input c= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For Instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS by Tim Scott dated 12/12/97. Please see attached copy of existing CF -1R and MF -1 R. 19 Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 1 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0405.00 Page:3 of 9 1 101 • Computer Method Summary (Part 3 of 3) C -2R ,,—.Quilling Remodel 6/16/04 lydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS ykit exist ung m m orma ion impute o e repo was taken from a previousTitle-24 repared by Tim Scott dated 12/12/97. Please see attached copy of existing CF -1 R and MF -1 R. Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 I EnergyPro 3.1 By EnergySoft User Number: 1086 Job Number. 0405.00 Page:4 of 9 ~THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 302 4.00 28 0_98 n/a 2 ZONE 2 ONLY / Slab on Grade Tile in Mortar 57 0.75 24 0.67 n/a 0 ZONE 3 ONLY / Interior Mass Concrete, Heavyweight 57 3.50 28 0.98 n/a 0 ZONE 3 ONLY / Slab on Grade Concrete, Heavyweight 638 420 28 0.98 n/a 2 _ ZONE 3 ONLY / Slab on Grade • PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 61 0.76 0.0 0 ZONE 3 ONLY HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / • pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments lydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS ykit exist ung m m orma ion impute o e repo was taken from a previousTitle-24 repared by Tim Scott dated 12/12/97. Please see attached copy of existing CF -1 R and MF -1 R. Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 I EnergyPro 3.1 By EnergySoft User Number: 1086 Job Number. 0405.00 Page:4 of 9 0 r-1 L 0 Computer Method Summary (Addendum) C -2R illing Remodel 6/16/04 Date special i-eatures ana moaeung ASSumpttons The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C-211) - Verify Thermal Mass: 700 sqft Tile in Mortar Interior Mass, 0.75" thick at Zone 1 HIGH MASS Design(see C-211) - Verify Thermal Mass: 700 sgft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 711 sgft Covered Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) -Verify Thermal Mass: 688 sgft Tile in Mortar Interior Mass, 0.75" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 688 sgft Exposed Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 302 sgft Covered Slab Floor, 4.00" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 57 sgft Tile in Mortar Interior Mass, 0.75" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 57 sgft Exposed Slab Floor, 3.50" thick at Zone 3 HIGH MASS Design(see C-211) - Verify Thermal Mass: 638 sgft Covered Slab Floor, 4.00" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Run InitiationTime: un Code: 1087407268 EnergyPro 3.1 By EnergySoft User Number: 1088 Job Number. 0405.00 Page:5 of 9 Is • Computer Method Summary (Part 1 of 3) C -2R 6/1'6/04 -Date • C.M. Energy Consulting (760) 346-8014 ocumen t o Author Te ep one Computer Performance 15 Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin • Space Heating 3.53 2.95 0.58 Space Cooling 37.69 91.14 -53.44 Domestic Hot Water 9.82 8.40 1.42 Totals 54-.0-4- 102.49 --ST-43— Percent better than Standard: Wall 164 0.059 • , Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: txlsting rsmialn 2,902 ft2 Single Fam Detached (Southwest) 225 deg 1.00 1 BUILDING ZONE INFORMATION Zone Name ZONE 1 ZONE 2 CY— ONE 3 • OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume rmatlon Building Permit 9----"—"" I Plan Check/Date Held ec a e J Floor Construction Type: F] Raised Floor ® Slab Floor Total Fenestration Area: 30.9% Total Conditioned Volume: 33,434 ft 3 Total Conditioned Slab Area: 2,902 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area 1,391 16,692 0.48 Conditioned Setback 2 n/a 816 9,792 0.28 Conditioned Setback 2 _ n1a 695 6,950 0.24 Conditioned Setback 2 n/a --- SO1af Gains Y / N Form 3 Reference Roof Wall Wall Wall • Wall 1,391 355 219 145 352 0.028 0.059 0.059 0.059 0.059 0 0 90 180 270 0 90 90 90 90 Door 18 0.387 270 90 Roof 816 0.028 0 0 Wall 158 0.059 90 90 Wall 80 0.059 135 90 Wall 164 0.059 180 90 Wall 28 0.059 225 90 Wall 30 0.059 270 90 Wall 48 0.059 315 90 Roof 695 0.028 0 0 Wall 336 0.059 0 90 Wall 36 0.059 90 90 Wall 224 0.059 180 90 Wall 234 0.059 270 90 r� V I'c I• R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Solid Wood Door R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 11-21 Wall (W.21.2x6.16) Location / Comments ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 I I EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0405.00 Page:6 of 9 I Computer Method Summary (Part 2 of 3) C -2R 6/16/04 Date # Type 0.76 3 Area Factor SHGC Act. Azm. Glazing Type Tilt 1 Window Left (North) 8.0 0.870 0.70 0 90 Double Clear Default (Mtl) 2 Window Left (North) 25.0 0.870 0.70 0 90 Double Clear Default (Mtl) 3 Window Rear (East) 30.0 0.720 0.73 90 90 Double Clear Default (Mtl) 4 Window Rear (East) 64.0 0.870 0.70 90 90 Double Clear Default (Mtl) 6 Window Rear (East) 64.0 0.870 0.70 90 90 Double Clear Default (Mtl) • 6 Window Rear (East) 30.0 0.720 0.73 90 90 Double Clear Default (Mtl) 7 Window Right (South) 15.0 0.720 0.73 180 90 Double Clear Default Mtl 6 Window ear (East) 96.0 0.870 0.70 ---9-T- -190 D-o-ubTe Clear Default (Mtl) 9 Window Rear (East) 42.0 0.870 0.70 90 90 Double Clear Default (Mtl) 10 Window Rear (East) 64.0 0.720 0.73 90 90 Double Clear Default (Mtl) Ti Window Right (Southeast) 64.0 0.870 0.70 135 90 Double Clear Default (Mtl) 12 Window Right (South) 40.0 0.720 0.73 180 90 Double Clear Default (Mtl) 13 Window Front (Southwest) 20.0 0.720 0.73 225 90 Double Clear Default (Mtl) 0 14 Window Front (Southwest) 28.0 0.870 0.70 225 90 Double Clear Default (Mtl) 15 Window Front (Southwest) 20.0 0.720 0.73 225 90 Double Clear Default (MU) 16 Window Front (West) 48.0 0.720 0.73 270 90 Double Clear Default (Mtl) 17 Window Front (West) 18.0 0.720 0.73 270 90 Double Clear Default (Mtl) 18 Window Left (Northwest) ' 48.0 0.720 0.73 315 90 Double Clear Default (Mtl) 19 Window Rear (East) 17.5 0.720 0.73 90 90 Double Clear Default (Mtl) 20 Window Right (South) 100.0 0.870 0.70 180 90 Double Clear Default (Mtl) 21 Window g t out) 30.0 0.720 0.73 80 90 Double t ear De au tl • 22 Window Front (West) 8.0 0.870 0.70 270 90 Double Clear Default (Mtl) 23 Window Front (West) 17.5 0.720 0.73 270 90 Double Clear Default (Mtl) OQ INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin # Exterior Shade Type SHGCgid Len. Hgt. LExt. RExt. Dist. Len. FT 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 T- Bug Screen 0.76 7- Bug Screen 0.76 IF ug Screen -076- 9 Bug Screen 0.76 10 Bug Screen 0.76 Tf Bug Screen �T� • T2 Bug Screen -07� ff Bug Screen 1- ug creen T5 ug creen X76 - T6 Bug screen M. 17 Bug Screen 0.76 i$ Bug screen 76 T5 ug screen � 3� ug creen �T� 3T ugcreen 22 Bug Screen 0.76 23 Bug Screen 0.76 0 Location/ Comments ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 2 ONLY - ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY ZONE 2 ONLY _ ZONE 2 ONLY ZONE 3 ONLY _ ZONE 3 ONLY ZONE 3 ONLY ----- - ZONE 3 ONLY ZONE 3 ONLY Fin Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 EnergyPro 3.1 By EneravSoft User Number. 1086 Job Number. 0405.00 Pagel of 9 HVAC SYSTEMS Heating Equipment Computer Method Summary Distribution Type (Part 3 of 3) C -2R Water Heater Water Heater Distribution Quilling Existing Type (furnace, heat Efficiency and Location Duct Thermostat Location / 6/16/04 - (AFUE/HSPF)(ducts/attic, roe a R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic Dae Setback THERMAL MASS FOR HIGH MASS DESIGN Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 2 Area Thick. Heat 4.2 Setback Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar 700 0.75 24 0.67 n/a 0 ZONE 1 ONLY / Interior Mass Concrete, Heavyweight 700 3.50 28 0.98 n/a 0 ZONE 1 ONLY /Slab on Grade Concrete, Heavyweight 691 4.00 28 0.98 n/a 2 ZONE 1 ONLY /Slab on Grade Tile in Mortar 688 0.75 24 0.67 n/a 0 ZONE 2 ONLY / Interior Mass Concrete, Heavyweight 688 3.50 28 0.98 n/a 0 _ ZONE 2 ONLY / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 35 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 59 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 32 0.76 0.0 0 ZONE 2 ONLY Slab Perimeter 50 0.76 0.0 0 ZONE 2 ONLY Slab Perimeter 20 0.76 0.0 0 ZONE 3 ONLY HVAC SYSTEMS Heating Equipment Minimum Distribution Type 1 Tank Insul. Water Heater Water Heater Distribution # in Input Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 2 Central Furnace 92%AFUE Ducts in Attic 4.2 Setback ZONE 3 ,Dydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. �0 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner Split Air Conditioner Large Split Air Conditioner 15.8 SEER Ducts.in Attic 4.2 Setback ZONE 1 14.0 SEER Ducts in Attic 4.2 Setback ZONE 2 11.0 EER Ducts in Attic 4.2 Setback ZONE 3 WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. AMERICAN G52 -50T38 -3N Small Gas Recirc/Time+Temp 1 35,000 50 0.60 n/a n/a •.- 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 EnergyPro 3.1 By Energysoft User Number. 1086 Job Number. 0405.00 Page:8 of 9 • Computer Method Summary (Part 3 of 3) C -2R Qui{ling Existing 6/16/04 THERMAL MASS FOR HIGH MASS DESIGN Minimum Duct Area Thick. Heat Duct Thermostat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 128 4.00 28 0.98 n/a 2 ZONE 2 ONLY / Slab on Grade Tile in Mortar 57 0.75 24 0.67 n/a 0 _ ZONE 3 ONLY / Interior Mass Concrete, Heavyweight 57 3.50 28 0.98 n/a 0 _ ZONE 3 ONLY / Slab on Grade Concrete, Heavyweight 638 4.00 28 0.98 n/a 2 ZONE 3 ONLY / Slab on Grade - • PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 61 0.76 0.0 0 ZONE 3 ONLY E: HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Oydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. � 7 1• •"- Li Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Energy Fact? 1 Tank Insul. WATER HEATING SYSTEMS Ratedl Tank Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated Input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 06/16/0410:34:28 Run Code: 1087407268 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0405.00 Page:9 of 9 Ole 9 0 0 o DI F=02 D=90 cl D=!3 D=00 0 0 0 1-9 , Thermal Performance Data 10 10 19 �.o Iv I* 19 � •o I* PRODUCT LINE DESCRIPTION & Glazing Variations THERMAL PERFORMANCE NTER AftT1%%IZED UNITS SHGC Vt "U" Cog U tot. Res U tot. NRes Res NRes Res NRes CLAD CASEMENT UNITS AA (Res)- 24 x 48 BB (NRes) - 30 x Single Glaze, Simulite, Clear, 1.5" width grid 1.12 1.00 1.02 0.55 0.53 0.54 0.54 Single Glaze, Simulite, Clear, .75" width grid 1.12 1.00 1.02 0.60 0.59 0.60 0.61 Single Glaze, One Lite, Clear 1.12 1.00 1.02 0.65 0.65 0.66 0.69 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.51 0.49 0.45 0.49 0.48 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.51 0.53 0.51 0.54 0.54 3/4" IG, One Lite, Clear 0.49 0.52 0.51 0.58 0.56 0.59 0.61 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.38 0.36 0.28 0.27 0.43 0.43 3/4 IG, Simulite, Low E' .75" width grid 0.30 0.38 0.36 0.30 0.30 0.48 0.48 3/4" IG One Lite, Low E' 0.30 0.38 0.36 0.32 0.33 0.52 0.54 CLAD AWNING UNITS AA (Res) - 48 x 24 BB (NRes) - 40 x 40 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 1.00 1.02 0.54 0.55 0.54 0.58 Single Glaze, Simulite, Clear, .75" width grid 1.12 1.00 1.02 0.59 0.60 0.59 0.63 Single Glaze, One Lite, Clear 1.12 1.00 1.02 0.64 0.65 0.65 0.69 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.51 0.48 0.48 0.48 0.51 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.51 0.53 0.52 0.53 0.56 3/4" IG, One Lite, Clear 0.49 0.52 1 0.51 0.57 1 0.56 1 0.59 0.61 3/4 IG, Simulite, Low E',.1.5" width grid 0.30 0.38 0.36 0.27 0.28 0.43 0.45 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.38 0.36 0.30 1 0.30 1 0.47 0.49 3/4" IG, One Lite, Low E• 0.30 0.38 0.36 0.32 0.33 0.52 0.54 CLAD FIXED UNITS AA (Res)- 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 1.04 1.05 0.59 0.57 0.59 0.60 Single Glaze, Simulite, Clear, .75" width grid 1.12 1.04 1.05 0.65 0.64 0.66 0.67 Single Glaze, One Lite, Clear 1.12 1.04 1.05 0.72 0.70 0.74 0.75 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.51 0.51 0.53 0.49 0.54 0.53 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.51 0.51 0.58 0.55 0.60 0.60 3/4" IG, One Lite, Clear 0.49 0.51 0.51 0.64 0.61 0.67 0.67 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.35 0.34 0.29 0.29 0.47 0.47 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.35 0.34 0.32 0.32 0.53 0.53 3/4" IG, One Lite, Low E' 0.30 0.35 0.34 0.35 0.35 0.59 0.59 CLAD DIRECT GLAZE UNITS AA (Res) - 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5' width grid 1.11 1.12 1.12 0.64 0.61 0.65 0.65 Single Glaze, Simulite, Clear, .75" width grid 1.11 1.12 1.12 0.71 0.68 0.73 0.72 Single Glaze, One Lite, Clear 1.11 1.12 1.12 0.78 0.75 0.80 0.80 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.51 0.57 0.53 0.59 0.57 3/4 IG, Simulite Clear, .75" width grid 0.49 0.52 0.51 0.63 0.58 0.66 0.64 3/4" IG, One Lite, Clear 0.49 0.52 0.51 0.69 0.64 0.73 0.71 3/4 IG, Simulite, Low E', 1.5' width grid 0.30 0.35 0.34 0.31 0.31 0.52 0.51 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.35 0.34, 0.34 0.34 0.58 0.57 3/4" IG, One Lite, Low E' 0.30 0.35 0.34 0.38 0.37 0.64 0.63 CLAD DIRECT GLAZE SASH SET UNITS AA (Res) - 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 1.02 1.04 0.58 0.57 0.59 0.60 Single Glaze, Simulite, Clear, .75" width grid 1.11 1.02 1.04 0.65 0.63 0.66 0.67 Single Glaze, One Lite, Clear 1.11 1.02 1.04 0.72 0.70 0.74 0.75 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.49 0.49 0.64 0.60 0.67 0.67 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.49 0.49 0.64 0.60 0.67 0.67 ou n u 3/4" IG, One Lite, Clear 0.49 0.49 0.49 0.64 0.60 0.67 0.67 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.33 0.32 0.29 0.28 0.47 0.47 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.33 0.32 0.32 0.31 0.53 0.53 3/4" IG, One Lite, Low E' 0.30 0.33 0.32 0.35 0.34 0.59 0.59 CLAD HORIZONAL SLIDER UNITS AA (Res)- 60 x 36 BB (NRes) -72 x 48 Single Glaze, Simulite Clear, 1.5' width grid 1.12 0.97 1.00 0.51 0.53 0.51 0.55 Single Glaze, Simulite, Clear, .75" width gdd 1.12 0.97 1.00 0.57 0.58 0.57 0.61 Single Glaze, One Lite, Clear 1.12 0.97 1.00 0.63 0.64 0.64 0.68 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.51 0.51 0.46 0.46 0.46 0.49 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.51 0.51 0.51 0.50 0.52 0.54 3/4" IG, One Lite, Clear 0.49 0.51 0.51 0.56 0.55 0.58 0.60 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.37 0.36 0.26 0.27 0.40 0.43 3/4 IG, Simulite, Low E', .75' width grid 0.30 0.37 0.36 0.29 0.29 0.46 0.48 3/4" IG, One Lite, Low E• 0.30 0.37 0.36 0.31 0.32 0.51 0.53 CLAD DOUBLE HUNG UNITS AA (Res)- 36 x 60 BB (NRes) -48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 0.95 0.98 0.51 0.53 0.51 0.55 Single Glaze, Simulite, Clear, .75" width grid 1.12 0.95 0.98 0.57 0.58 0.57 0.61 Single Glaze, One Lite, Clear 1.12 0.95 0.98 0.63 0.64 0.64 0.68 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.49 0.50 0.46 0.46 0.46 0.48 3/4 IG, Simulite, Clear, .75' width grid 0.49 0.49 0.50 0.51 0.50 0.52 0.54 3/4" IG, One Lite, Clear 0.49 0.49 0.50 0.56 0.55 0.58 0.60 3/4 IG, Simulite, Low E', 1.5' width grid 0.30 0.36 0.35 0.26 0.27 0.40 0.43 3/4 IG, Simulite, Low E•, .75" width grid 0.30 0.36 0.35 0.29 0.29 0.45 0.48 3/4" IG, One Lite, Low E` 0.30 0.36 0.35 0.31 0.32 0.51 0.53 CLAD DOUBLE HUNG PICTURE UNITS AA (Res)- 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 0.95 0.98 0.59 0.57 0.59 0.60 Single Glaze, Simulite, Clear, .75' width grid 1.12 0.95 0.98 0.65 0.64 0.66 0.67 Single Glaze, One Lite, Clear 1.12 0.95 0.98 0.72 0.70 0.74 0.75 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.49 0.49 0.53 0.49 0.54 0.53 3/4 IG Simulite, Clear, .75" width grid 0.49 0.49 0.49 0.58 0.55 0.60 0.60 3/4" IG, One Lite, Clear 0.49 0.49 0.49 0.64 1 0.61 1 0.67 0.67 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.36 0.35 0.29 0.29 0.47 0.47 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.36 0.35 0.32 1 0.32 1 0.53 0.53 3/4" IG, One Lite, Low E' 0.30 0.36 0.35 0.35 0.35 0.59 0.59 CLAD SLIDING PATIO DOOR UNITS AA (Res) - 72 x 82 BB (NRes) -- 72 x 96 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.91 0.92 0.49 0.48 0.48 0.48 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.91 0.92 0.53 0.52 0.52 0.53 Single Glaze, One Lite, Clear 1.11 0.91 0.92 0.57 0.56 0.57 0.57 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.49 0.50 0.44 0.42 0.43 0.43 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.49 0.50 0.48 0.45 0.47 0.47 3/4" IG, Ohe Lite, Clear 0.49 0.49 0.50 0.51 0.48 1 0.51 0.51 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.37 0.37 0.25 0.25 0.38 0.38 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.37 0.37 0.27 0.27 0.42 0.41 3/4" IG, One Lite, Low E' 0.30 0.37 0.37 0.29 0.28 1 0.45 0.45 CLAD DOOR TRAMSOM UNITS AA (Res)- 16 x 82 BB (NRes) -16 x 82 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.82 0.87 0.26 0.15 0.20 0.09 Single Glaze, Simulite, Clear, .75" width gdd 1.11 0.82 0.87 0.32 0.29 0.28 0.25 Single Glaze, One Lite, Clear 1.11 0.82 0.87 0.39 0.43 0.35 0.42 3/4 IG, Simulite, Clear, 1.5' width grid 0.49 0.53 0.53 0.24 0.14 0.18 0.08 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.53 0.53 0.29 0.26 0.25 0.22 3/4" IG, One Lite, Clear 0.49 1 0.53 0.53 0.35 1 0.38 1 0.32 0.37 3/4 IG, Simulite, Low E', 1.5' width grid 0.30 0.46 0.46 0.16 0.11 0.16 0.07 3/4 IG, Simulite, Low E', .75' width grid 0.30 0.46 0.46 0.18 0.17 1 0.22 0.20 3/4" IG, One Lite, Low E' 0.30 0.46 0.46 0.22 0.23 0.28 0.33 CLAD DOOR SIDELITE UNITS AA (Res) -16 x 82 BB (NRes) -16 x 82 i! (1) i! I! ! 1! iso I! Ni 1 !U Sin le Glaze Simulite, Clear, 1.5" width grid 1.11 0.70 0.21 0.20 1 0.15 0.15 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.70 0.25 0.24 0.19 0.19 Single Glaze, One Lite, Clear 1.11 0.70 0.29 0.28 0.24 0.24 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.50 0.19 0.18 0.14 0.13 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.50 0.23 0.21 0.18 0.17 3/4" IG, One Lite, Clear 0.49 1 0.50 0.26 0.25 0.22 0.21 3/4 IG, Simulite, Low E•, 1.5" width grid 0.30 0.45 1 1 0.13 0.13 0.12 0.12 3/4 IG, Simulite, Low E', .75' width grid 0.30 0.45 0.15 0.15 1 0.16 0.15 3/4" IG, One Lite, Low E" 0.30 0.45 0.17 0.17 0.19 0.19 DOOR CLAD INSWING AND RADIUS TOP INSWING AA (Res)- 38 x 82 BB (NRes) - 38 x 82 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.85 0.44 0.42 0.42 0.42 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.85 0.49 0.46 0.48 0.47 Single Glaze, One Lite, Clear 1.11 0.85 0.54 0.51 0.54 0.53 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.46 0.39 0.36 0.38 0.37 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.46 0.43 0.40 0.43 0.42 3/4" IG, One Lite, Clear 0.49 0.46 0.48 1 0.44 1 0.48 0.47 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.35 0.23 0.22 0.34 0.33 3/4 IG, Simulite, Low E•, .75" width grid 0.30 0.35 0.25 0.24 0.38 0.37 3/4" IG, One Lite, Low E• 0.30 0.35 0.27 0.26 0.43 0.41 CLAD INSWING SIDELITE UNITS AA (Res) - 16 x 82 BB (NRes) -16 x 82 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.64 0.20 0.19 0.15 0.15 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.64 0.24 0.23 0.19 0.19 Single Glaze, One Lite, Clear 1.11 0.64 0.28 0.27 0.24 0.23 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.43 0.18 0.17 0.14 0.13 3/4 IG, Simulite, Clear, .75' width grid 0.49 0.43 0.21 0.20 0.17 0.17 3/4" IG, One Lite, Clear 0.49 0.43 0.25 0.23 0.22 0.21 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.38 0.12 0.12 0.12 0.12 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.38 0.14 0.14 0.15 0.15 3/4" IG, One Lite, Low E" 0.30 0.38 0:16 0.15 0.19 0.18 CLAD OUTSWING DOOR UNITS AA (Res)- 38 x 82 BB (NRes) - 38 x 82 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.90 0.45 0.43 0.43 0.42 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.90 0.50 0.48 0.48 0.47 Single Glaze, One Lite, Clear 1.11 0.90 0.55 0.52 0.54 0.53 3/4 IG, Simulite Clear, 1.5" width grid 0.49 0.51 0.40 0.37 0.39 0.37 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.51 0.45 0.41 0.44 0.42 3/4" IG, One Lite, Clear 0.49 0.51 0.49 0.46 0.49 0.47 3/4 IG, Simulite, Low E", 1.5' width grid 0.30 0.40 0.24 0.23 0.34 0.33 3/4 IG, Simulite, Low E", .75' width grid 0.30 0.40 0.26 0.25 0.39 0.37 3/4" IG, One Lite, Low E' 0.30 0.40 0.28 0.27 0.43 0.42 CLAD OUTSWING SIDELITE UNITS AA (Res) -16 x 82 BB (NRes) -16 x 82 Sin le Glaze, Simulite, Clear, 1.5" width grid 1.11 0.73 0.22 0.21 0.16 0.16 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.73 0.26 0.25 0.20 0.20 Single Glaze, One Lite, Clear 1.11 0.73 0.30 0.29 0.25 0.25 3/4 IG, Simulite Clear, 1.5" width grid 0.49 0.52 0.20 0.19 0.14 0.14 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.24 0.22 0.18 0.18 3/4" IG, One Lite, Clear 0.49 0.52 0.27 0.26 0.23 0.22 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.47 0.14 0.14 0.13 0.12 3/4 IG, Simulite, Low E', .75'.width grid 0.30 0.47 0.16 0.15 0.16 0.16 3/4" IG, One Lite, Low E' 0.30 0.47 0.18 0.17 0.20 0.19 CLAD SWING DOOR TRANSOM AA (Res)- 38 x 14 BB (NRes) - 74 x 14 Single Glaze, Simulite, Clear, 1.5" width. grid 1.11 0.84 0.89 0.36 0.40 0.31 0.37 Single Glaze, Simulite, Clear, .75' width grid 1.11 0.84 0.89 0.38 0.42 0.33 0.39 Single Glaze, One Lite, Clear 1.11 0.84 0.89 0.40 0.43 0.35 0.41 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.56 0.56 0.33 0.35 0.28 0.33 3/4 IG, Simulite, Clear, .75" width grid 1 0.49 0.56 0.56 0.34 0.37 0.30 0.35 3/4" IG, One Lite, Clear 1 0.49 0.56 1 0.56 1 0.36 1 0.38 0.32 0.37 0 i - Table 1-D Default Fenestration Product U -Factors • • ' Metal includes any field -fabricated product with metal cladding. Non-metal framed fenestration products with metal cladding must add 0.04 to the listed U -factor. Non -Metal frame types can include metal fasteners, hardware, and door thresholds. Thermal break product design characteristics are: a. The material used as the thermal break must have a thermal conductivity of not more than 3.6 Btulnch/hr/ft2/'F, b. The thermal break must produce a gap of not less than 0.210", and c. All metal members of the fenestration product exposed to interior and exterior air must incorporate a ,thermal break meeting the criteria in (a) and (b) above. In addition, the fenestration product must be clearly labeled by the manufacturer that it qualifies as a thermally broken product in accordance with this standard. 2 For all dual glazed fenestration products, adjust the listed U -factors as follows: a. Subtract 0.05 for spacers of 7/16" or wider. . b. Subtract 0.05 for products certified by the manufacturer as low -E glazing. c. Add 0.05 for products with dividers between panes if spacer is less than 7/16" wide. d. Add 0.05 to any product with true divided lite (dividers through the panes). s 1 INDI �[�S �EATLI�) 11'(ILIZ�l7 WITNl�1�NIs LoM pN� GALGULP"j"ION 'v 0 r� U 1• I• 1• � 00 1• 1• Table 1-E Default Solar Heat Gain Coefficient SHGC = Solar Heat Gain Coefficient ti. � ► INlca ES,EP�TURCS) llTILlz.�p W111�iN TRIS GoM�LIh GE GALGJLNTIoN !'o I• y. t ..4; f 9 U- t .7 t T !,n S " q r' gg `A iY • Y i E7. 7ww► . •iv 00 !y 40 io Ift • r .O%,r !r: i(.•a:rY r.t' - .:� •:r,Y, s r t .. •-f_ i N: - d'Y�r'+.: r. . 'h+ ^cv .t � ._t•'' !�� •. :-S, is "'I-' J F S rP r.( y i V� "L .9i. x iL' '•�9 . , ��R ,J Y �,•,'] Jr��Y y aA' n 7 .: �•: t 1- , r. a} s' :5 • 4 -C �5S :e r S J JT. yc Y >Sh r.5 n z` .:F F :c- it y' .5` ?n - w;. yt`l•.- s ��i:r-�:lilllc"• - - i` l -1. r ..v .y 1 v r 1. - I: a. .-r k - �!• .rt a, l_ li n NA ;s s� ?'lv: �,: ,,!! ..i �-•: ,y;,_ r� s's5=;�'%%-. v rte:.; • , •S • •C' i 6y= �v lam'^ :.r J. 'max'•. - �L' _;3:,, ,,x..y:: 1. 4E�a _..�..' vt�J' yt d.'. .r -R: ��.,., �•.� :,*. K` f• >rr J: 4� . L. -ri! ,i f ' .A ^tr . _ '�- i ,� F. J s. •c 4. �..t: g.. i. _ S'� • Vit.. •:rv' t> t' i��• : r. ryt. 5� {" '- n i71 ' i CERTIFI ATE OF COMPLIANCE - Residential ( part 1 of 2) CF -1R page 3 of 42 --------------------------------------------------------------------------- F'eojoct Na' : Gardner C-esidence ;Date= 12/12/1997 Address: Lot 89, --act 28470. Traditions ; La Quints. Ca ;Building Permit No Designer: Robert S. R _ =='�eY . Architect ; Checked by / Date Documentation: BREEZE CONDITIONING ;COMPLY 24 User 3665 GENERAL INFORMATION Compliance Method: COMPLY 24 version 5.10 CZi:mate 15 .Zone: CO- ditioned Floor = =- 3475 sgft BuType: Newilding Occupancy Type: Single Fam Det Bu'jiding Front OTIS- ---- on: 270 deg (W) r Number of Dwelling -'=== 1 Floor Construction - -= slab on Grade BUILDING SHELL INSUL= Component U -value Location/Comments R- 2i Wald (W.21 2x6 O .059 Master Suite R-21.;Wall (W .21 -2x6 . =- 0.059 Kit/Morn/Din/Entry R -2.1 -Wall (W .21 .2x6..= 0.059 Great/Media/Workout Solid wood Door 0.387 Great/Media/Workout R-21 .Wal.l (W .21 .2x6.:- 0.059 Guest Suite R-3$�-Roof(R.38.2x14..- 0.029 Master Suite *Q R-38. Roof (R .38 .2x 14 . =' 0.029 Kit/Morn/Din/Entry 1--38.Robf(R .38 .2x1s . - O .029 Great/Media/Workout R-38' Roof(R .38 .2X14 . -_ 0.029 Guest Suite SlabPerimeter w./R-: 0-900 Master Suite Slab Perimeter w%R-= = 0.720 Master Suite Slab Perimeter w/R-: = 0.900 Kit/Morn/Din/Entry Slab Perimeter w/R__ = 0.720 Kit/Morn/Din/Entry Slab perimeter w/R-: = 0.900 Great/Media/Workout Slab'Perimeter w/R--: = 0.720 Great/Media/Workout Slab Perimeter w/R--- 0.900 Guest Suite Slab -Perimeter w/R-: = 0.720 Guest Suite FENESTRATION Shading Devices Frame Orient. Area _- -- -ze Interior Exterior OH SF Type Left. (N) 11.0 -= :°=,-ole Std Drape none Y N Metal Left. (N) 8.0 = : Ie Std Drape Standard Bug Scr N N Metal Left (N) 25.0 := __ ale Std Drape Standard Bug Scr Y N Metal • Back (E) 30.0 =- - =-ale Std Drape none N N Metal Ba.c'k (E) 145.3 _= -:,-:Die Std Drape none Y N Metal Back (E) 304-0 1e Std Drape Standard Bug Scr Y N Metal Back i SE) 64 .O =- = =�=1e Std Drape Standard Bug Scr Y N Metal Right (5) 15.0 _= -=��1e Std Drape none N N Metal Right (S) 8-0 : _- = =1e Std Drape none Y N Metal Right (5) .128.0 1e Std Drape Standard Bug Scr Y N Metal 0 Right (5) 8.0 _- = =•_ale Std Drape none Y N Metal, 'zlight (5) 40.0 1e Std Drape Standard Bug Scr Y N Metal Right (S) 30.0 -- - ��le none none Y N None Right ( 5W) 16'. 0 _- - -,-=1e Std Drape none Y N Metal Right ( SW) 28-0 := - =�= le none none Y N Metal front ( w) 8..0 _- - =-ale Std Drape none N N Metal Front (u) 90.0 - 1e Std. Drape none Y N Metal :=_ale Std Drape none ' + Q Y N Metal CERTIFICATE OF COMPLIANCE - Residential ( part 1 of 2) CF -1R page 3 of 42 PrQ1ei:1t Name= Gardner Residence ;Date= 12/12/1997 `Address= Lot 89, Tract 28470. Traditions La Quinta, Ca ;Building Permit No Designer: Robert S. fRitchey, , Architect 'Checked -by / Date Documentation: BREEZE AIR CONDITIONING ;COMPLY' --------------------------------------------------- --------------- 24 User 3665 ------GENERAL INFORMATION • Compliance Methods COMPLY 24 version 5.10 Quinate Lone= 15 d6tid.it'ioned Floor Areas 3475 sqft B.Uiid-ing Types New Occupamcy Type= Single Fam Det Bull.ng Front Orientations 270 deg (W) Nurser of Dwelling Units: 1 F:16o-e Construction Type= Slab on Grade BUILPI:NG SHELL INSULATION Compane:nt U -value Location/Comments • R -2T 44a) 1 (W.21 .2X6.16) O .059 Master Suite R -21. -Wall (W .21 .2x6 . i6-) 0.059 Kit/Morn/Din/Entry R-21 -Wall (W .21 .2x6 .16) 0.059 Great/Media/Workout Solid'Wood Door 0.387 Great/Media/Workout R•-21 Wa11 (W ."21 .2x6.16) 0.059 Guest Suite R -3e- Roof(R .38 .2x14 .16) 0.029 Master Suite *0 R-38 'Roof (R .38 .2x 14.16) 0.029. Kit/Morn/Din/Entry .Z -38..:R -of ( R .38 .2xi4 .16) 0.029 Great/Media/Workout R -38 -Roof (R . 38 .2 x 14...16) 0.029 Guest Suite Slab Perimeter w/R-0.0 0.900 Master Suite Slab Perimeter w/R-0.0 0.720 Master Suite Slab Perimeter w/R-0.0 0.900 Kit/Morn/Din/Entry Slab Perimeter w/R-0.0 0.720 Kit/Morn/Din/Entry Slab Perimeter w/R-0.0 0.900 Great/Media/Workout Slab'Perimeter w/Rl0.0 0.720 Great/Media/Workout Slab Perimeter w/R-O.O 0.900 Guest Suite Slab: Per i.meter w/R-0.0 0.720 Guest Suite FENESTRATION Shading Devices Frame Orient. Area U -Val Type Interior Exterior OH SF Type Left:. (N) 11.0 0.55 Double Std Drape none Y N Metal Left (N) 8.0 0.69 Double Std Drape Standard Bug Scr N N Metal Left' (N) 25.0 0.69 Double Std Drape Standard Bug Scr Y N Metai • Back (E) 30.0 0.55 Double Std Drape none N N Meta` Back (E.) 145.3 0.55 Double Std Drape none Y N Metal Back (E) 304.0 0.65 Double Std Drape Standard Bug Scr Y N Meta •, Back (SE) 64.0 0.65 Double Std Drape Standard Bug Scr Y N Metal Right (S) 15 .O 0.55 Double Std Drape none N N Meta Right �(5 ), 8.0 0.55 Double Std Drape none Y N Meta Right (S) .128.0 0.65 Double Std Drape Standard Bug Scr Y N Meta'. Right (5) 8.0 0.69 Double Std Drape none Y N Metai "Right (5) 40.0 0.69 Double Std Drape _Standard Bug Scr Y N Meta:. Right .(.S) 30.0 0.72 -Double none none Y N None Right (SW) 16.0 0.55 Double Std Drape none Y N Meta.. Right (5W) 28.0 0.65 Double none none Y N Meta- eta_Front Front(W) 8_0 0.55 Double ' Std Drape none N N Meta-. Front (W) 90.0 0.55 Double Std Drape none Y N Meta _ Vir-'nnt (.-NW ) 48.-0 0-55 D011M P_ Std Or aoe none r �;; i Y N Meta 1 • ciao rer ia+er-er (part 2 of 0.900 Master Suite Slab Perimeter w/R-0.0 0.720 Master Suite • Slab Perimeter w/R-0.0 0.900 Kit/Morn/Din/Entry --------- Slab Perimeter w/R-O.O 0.720 Kit/Morn/Din/Entry slab,P,e•rimeter w/R-O.O ,Date: 12/12/1997 0.900 Great/Media/Workout Documentation: BREEZE AIR CONDITIONING Slab• -Perimeter w/R-0.0 0.720 Great/Media/workout Slab Perimeter w/R-0.0 0.900 Guest Suite :COMPLY ;COMPLY 24 User 36 ------------------ Slab Perimeter w/R-0.0 HVAC SYSTEMS Minimum 0.720 Guest Suite Duct TStat FENESTRATION �,J -, Shading Devices F Rval Orient. Area U -Val Type Interior Exterior OH SF 'r _ ___ Attic Lef t. ( N ) 11.0 0.55 Double Std Drape none Y N M Ducts in Ducts in Left (N) 8.0 0.69 Double. Std Drape Standard Bug Scr N N M SpItAItCond14.000 SEER Left (N) 25.0 0.69 Double Std Drape Standard Bug Scr Y N M= • Bac:k (E) 30.0 0.55 Double Std Drape none N N M<. Great/Media Zone Bac-R JE) 145.3 0.55 Double Std Drape none Y N Mt SetBck �..-.--- Back (E) 304.0 0.65 Double Std Drape Standard Bug Scr Y N M> 'd Back (SE) 64.0 0.65 Double Std Drape Standard Bug Scr Y N.M- .Right ( S) 15.0 0.55 Double Std Drape none N N Mi Right X S ) 8-0 0.55 Double Std Drape none Y N M- Right (S) 128.0 0.65 Double Std Drape Standard Bug Scr Y N MF Right' (5) 8.0 0.69 Double Std Drape none Y N ME '.Right (5) 40.0 0.69 Double Std Drape Standard Bug Scr Y N Mt Right .(.S ) 30.0 O .72 . Double none none Y N NC Right (SW) 16.0 0.55 Double Std Drape none Y N ME Right ( SW ) 28:.0 0.65 Double none none Y N ME. front_ (W) 8i.0 0.55 Double Std Drape none N N ME Front ( W ) 90".0 0.55 Double Std Drape none Y N Me Front (NW ) 48;_0 0..55 Double Std Drape none Y N M% Skyli:g.ht 4.0 0.80 Double none none N N M 460 THERMAL MASS Area Thick Type Covering -------- (sf) (in) ----- ----- Location/Description --------------------------- --------------------- Cone r Heavyweight Exposed 57 3.50 Slab on Grade Concrete, Heavyweight Covered 638 3-50 Slab on Grade Concrete, Heavyweight Exposed 688 3.50 Slab on Grade �oncrete, Heavyweight Covered 128 3.50 Slab on Grade Concrete, Heavyweight Exposed 700 3.50 Slab on Grade .Concrete, Heavyweight Covered 691 3.50 Slab on Grade Concrete, Heavyweight Exposed 17 3.50 Slab on Grade Concrete, Heavyweight Covered 556 3.50 Slab on Grade 1 • CERTIFICATE OF COMPLIANCE - Residential (part 2 of 2) -------------------------- CF -1R page 4 of Project Name= Gardner Residence --------- ,Date: 12/12/1997 Documentation: BREEZE AIR CONDITIONING -------------------------------------------------- :COMPLY ;COMPLY 24 User 36 ------------------ HVAC SYSTEMS Minimum Oistrib Type Duct TStat �,J -, System Type Efficiency ------------ ----- and Location Rval Type Location/Comments Furnace 0.800 AFUE SpltAirCond15.750 SEER Ducts in _ ___ Attic _ 4..2 _ _ SetBck Master Suite Zone- Furnace 0.800 AFUE Ducts in Ducts in Attic Attic 4.2 SetBck SpItAItCond14.000 SEER Ducts in Attic 4.2 SetBck Kit/Morn/Din Zone Furnace 0.800 AFUE SpltAirCond14.000 SEER Ducts in Attic 4.2 4.2 SetBck SetBck Great/Media Zone Furnace 0.800 AFUE Ducts in Ducts in Attic Attic 4.2 SetBck �..-.--- 'd - SpltAirCond14.000 SEER Ducts in Attic Furnace 0.800 AFUE Ducts in Attic SpltAirCond14.000 SEER Ducts in Attic Furnace 0.800 AFUE Ducts in Attic Splt4irCohd13.000 SEER Ducts in Attic T.� ac�,ocR mit/Morn/Din Zone 4.2 SetBck 4.2 SetBck Great/Media Zone 4.2 SetBck 4.2 SetBck Guest Suite Zone 4.2 SetBck u SPECIAL FEATURES/REMARKS COMPLIANCE S T A T EMEN T This Certificate of Compliance lists the Building features and performance 41 specifications needed to comply with Title 24, Parts 1 & 6 of the.Califor- nia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. when this certificate of compliance is submitted for a single Buiiding plan to be built in multiple orientations, any shading •feature that is varied is indicated in the Special Features/Remarks section DE5IGNER or OWNER (Per Business & Professions Code) Robert S. Ritchey, Architect 42-575 Melanie Place palm Desert, Ca 92211 ( 760 ) 341-699Z L i c = (signature) ENFORCEMENT AGENCY Name: ritle Agency= Telephone - 00 0 ( date ) DOCUMENTATION AUTHOR Tim Scott BREEZE AIR CONDITIONING 75-145 ST CHARLES PLACE PALM DESERT, CA 92260 ( 619) 346-08 5 V (signature) (date ) (signature/stamp) ( date ) Water No. Tank Ext. WATER HEArjroi S'fsrEMS Heater in Energy Size Insui w System Name Distribution Type Type Sys Factor (gal) R-Vai American G52-50T383N Recirc-Time&Temp StorGas 2 0.60 50.0 12.0 American G52 -30r33 -3N Recirc-Time&Temp StorGas 1 0.61 30.0 12.0 AFUE WATER HEATER EUULPMENT OErAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light American G52-b0T383N DomesticHW 0.780 38000 0.003 16.0 0 american G52 -30x33 -3N DomesticHW 0.780 33000 0.003 16.0 O u SPECIAL FEATURES/REMARKS COMPLIANCE S T A T EMEN T This Certificate of Compliance lists the Building features and performance 41 specifications needed to comply with Title 24, Parts 1 & 6 of the.Califor- nia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. when this certificate of compliance is submitted for a single Buiiding plan to be built in multiple orientations, any shading •feature that is varied is indicated in the Special Features/Remarks section DE5IGNER or OWNER (Per Business & Professions Code) Robert S. Ritchey, Architect 42-575 Melanie Place palm Desert, Ca 92211 ( 760 ) 341-699Z L i c = (signature) ENFORCEMENT AGENCY Name: ritle Agency= Telephone - 00 0 ( date ) DOCUMENTATION AUTHOR Tim Scott BREEZE AIR CONDITIONING 75-145 ST CHARLES PLACE PALM DESERT, CA 92260 ( 619) 346-08 5 V (signature) (date ) (signature/stamp) ( date ) 0 • 0 • 0 Sec. 150(d).: Minimum R-13 ra.is.ed f loor-` Insu-hatian � n fr-timed`' floors; Minimum. R-8 in. cd cr4Ae raised. loons. Sec.. 150( 1 )s .S.1ab edge ..insulation wer.absorpt:id:n rate -no greater than. 0.3"c, water vapor tr:an$m .ssi n rate :no :greater than 2,.0 perm/Inch. Sec. 118: insulation specified or installed meets eaii.fornia . .Energy Commission. quality standar'�ds.-% i.nd-icate Type .� .foram Sec. 116-117: Fenestratio. Products;; ext, Daoirs &L:nf%l/EXi-Y`'iCoTttrQ.ls a:: Doors and windows hetwee-n. condi:tianed a.nd u:ncottd: ;tioited.:.: . spaces.: designed to 1 mit, air 1eak2t e. b. Manufacture:fit fen est.ra.tion produ6t:6 nave `babel : icer.rf.iid ` jvalue.: c. Exterior doors and. windows weatheirstrippecfi; and penetrations. caulked and sea:led... �. 159(p)` vapor bare iere mandat.or..y in Climate Zones .7 4 and ib only. o Sec. 150( f )c . Special infiltrationba:rrieir instaifed .to comply with Seic.. , 1b1 meets Commission..gwal :ty..'s:tandards. o Sec. 150(e): installation of Fireplaces, Decorative Gas Appliances and GOLS Logs.. 1. Masonry and factory -built fireplaces have: • a. Closeable metal or .:glass .door b. Outside ai-r. intake with damper. anal control. c. Flue damper and -control 2. No continuous burning gas pilots aILowed :. LI 0 MANDATORY MEASURES CHECKLIST (part 2 of 2) Mf -2R page 6 .0 f, '----------------------------------------- -- -- - ---- __ Project Name: Gardner Residence 0, g ats=. .12%12'91997 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 'User 36 SPACE CONDI iIONING WATER HEAPING AND-OLUMBING. SYSTEM:A.SUO`t5y Enfo'r-ce � m e 0 Sec 110-13: HVAC equ:xpme.nt, water heaters, showerheads and faucets certified: by the Commistian... o sec. 150(i): Setback thermostat on all applicable heating systems. 0 sec. 150(1)- Pipe and Tank Insulation 1. Indirect ho,t water tanks (.eq unfired storage.,.ta'ns or. backup solar hot water tanks) have . insulation blanket (R-1.2 or greater.') or combined interior/exterior inswla.t=ian: (R-16 or greater). 2. First 5 feet of pipes closest to water heater :.tank, non-recirculation systems, insulae-ed;.(R-4 orgrea.ts:r.- 3. All buried or exposed piping insGla.ted in recdreul:at:on sections of hot water system. 4. Cooling system piping below 55 F insulated. 5. Piping insulated between heating. source and indir.-ec:t hot- water tank. o Sec. 150(m) Ducts and Fans.. 1 . Ducts constructed, installed and sealed to comply with UMC Sections 1002• and 1004; ducts: 'i n:'O'uhated to- a i i.n intim` R-4.2 or ducts .enclosed entirely w'*•hi,•n Gond" t..io:ned• space .. - 2. Exhaust systems have backdrart, or su:tQmatic damp -e-6.3. Gravity ventilating systems serving `eo•nd.itioned SPAPe.,.haue either automatic of readily acc:es.s ble ma.nua:lly :oP@rated" dampers. o Sec. 114:Pool and Spa Heating Systems.and Egwipme:nt * 1. system is certified with 78% thermal effici.e.ncy pn-:off, switch, weatherproof' operating instructions, no- ele'c•tr1c;. resistance heating and no pilot light. 2. System is installed with: a'. At least 36" pipe between filter anal heater for future solar heating. 0 b--Cover fo'r eu'tdoor pools or outdoor spas . 3. Pooi system has directional, inlets arid' a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater. spa heater.. or household cooking appliance have no continuously, 0, burning pilot light. (Exception: Non-electrical cooking appliance with pilot <, 150 stuh) LIGHTING MEASURES o sec. iSo( k): Lighting 40 lumens/watt or greater : fo.r general lighting in kitche=ns a:nd rooms with water -closets; and recessed ceiling fixtures IC (.insulation -cover.). approved.