Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-0603 (RER) Title 24
t 4 BUILDING ENERGY ANALYSIS REPORT PROJECT: Dr. & Mrs. Carl Highgenboten 78-180 Hacienda La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 1�EC�IVE� MAY 3 12012 BY: CITY OF LA QUINTq Job Number: LDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT Q/ l2_ BY Date: 5/16/201212 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the. Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: 0 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary EnergyPro 5.1 by Energysoft Job Number. ID: User Number: 6712 1 2 3 13 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 1511612012 Date Project Address 78-180 Hacienda La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 4,657 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ( Features see Part 2 of 5 Status Roof Wood Framed Attic R-11 4,597 Existing Wall Wood Framed None 3,271 Existing Wall Wood Framed R-13 182 Altered Door Opaque Door None 60 Existing Slab Unheated Slab -on -Grade None 4,657 Perim = 447' Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 4.0 0.710 0.60 none none None Removed Skylight 4.0 0.710 0.60 none none None Removed Skylight 4.0 0.710 0.60 none none None Removed Skylight 6.0 0.710 0.60 none none None Removed Skylight 0.8 0.300 0.30 none none None New Skylight 0.8 0.300 0.30 none none None New Skylight 0.8 0.300 0.30 none none None New Skylight 0.8 0.300 0.30 none none None New Skylight 26.4 0.710 0.60 none none None Existing Skylight 10.8 0.710 0.60 none none None Existing Skylight 19.6 0.710 0.60 none none None Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-05-16T09:51:05 ID: Page 3 of 15 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/16/2012 Project Address 78-180 Hacienda La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,657 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes 0 No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (NE) 13.8 1.040 0.76 none none Bug Screen Existing Rear (E) 302.2 1.040 0.76 none none Bug Screen Existing Rear (E) 48.0 0.460 0.39 none none Bug Screen Altered Rear (E) 6.0 1.040 0.76 none none Bug Screen Removed Right (S) 202.2 1.040 0.76 none none Bug Screen Existing Right (S) 47.2 1.040 0.76 none none Bug Screen Removed Right (S) 32.0 0.530 0.46 none none Bug Screen New Right (S) 40.2 0.530 0.46 none none Bug Screen Altered Front (W 44.9 1.040 0.76 none none Bug Screen Removed Front (lM 186.8 1.040 0.76 none none Bug Screen Existing Front (NtM 13.8 1.040 0.76 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Pa e 4 of 15 0 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration 1511612012 Date Project Address 78-180 Hacienda La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,657 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures — If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features .-- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 77.1 1.040 0.76 none none Bug Screen Removed Left (N) 368.0 1.040 0.76 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Page 5 of 15 t• 0 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 5/16/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 1,200.0 ft' Covered Slab Floor, 3.500" thick at Altered Residence HIGH MASS Design - Verify Thermal Mass: 3,457. 0 ft' Exposed Slab Floor, 3.500" thick at Altered Residence HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. IT-emyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-05-16T09:51:05 ID: Page 6 of 15 • • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Dr. & Mrs. Carl Highgenboten ❑ Multi Family m Existing+ Addition/Alteration 5/16/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 21.80 19.95 1.85 Space Cooling 243.77 244.75 -0.97 Fans 45.08 44.92 0.17 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 310.66 309.61 1.05 Percent Better Than Standard: 0.3% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (IM 250 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (M 1,540 201 Fuel Available at Site: Natural Gas (N) 1,140 382 Raised Floor Area: 0 (E) 966 350 Slab on Grade Area: 4,657 (S) 1,074 274 Average Ceiling Height: 14.0 Roof 4,657 60 Fenestration Average U -Factor: 0.99 TOTAL: 1,267 Average SHGC: 0.73 Fenestration/CFA Ratio: 27.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 5/16/2012 Address 77-085 Michigan Drive Name Jon Scott Cit /State2i Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation q:;iiig installer testing and certification and field verification by an approved Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and DraftingAddress 77-622 Country Club Dr. Suite O Name RobertPitchford / City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed Licens # Date EnerqvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Page 7 of 15 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1511612012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 4,597 0.079 R-11 0 20 Existing 4.2.1-A2 Altered Residence Wall 42 0.356 None 25 90 Existing 4.3.1-A1 Altered Residence Wall 434 0.356 None 70 90 Existing 4.3.1-A1 Altered Residence Wall 182 0.102 R-13 70 90 Altered 4.3.1-A3 E=4.3.1 -A1 Altered Residence Wall 176 0.356 None 70 90 Remove 4.3.1-A1 Altered Residence Wall 739 0.356 None 160 90 Existing 4.3.1-A1 Altered Residence Door 20 0.500 None 160 90 Existing 4.5.1-A4 Altered Residence Door 40 0.500 None 160 90 Existing 4.5.1-A4 Altered Residence Wall 140 0.356 None 160 90 Remove 4.3.1-A1 Altered Residence Wall 1,297 0.356 None 250 90 Existing 4.3.1-A1 Altered Residence Wall 176 0.356 1 None 250 90 Remove 4.3.1-A1 Altered Residence Wall 42 0.356 None 295 90 Existing 4.3.1-A1 Altered Residence Wall 716 0.356 None 340 90 Existing 4.3.1-A1 Altered Residence Wall 140 0.356 None 340 90 Removec 4.3.1-A1 Altered Residence Slab 1,200 0.730 None 0 180 Existing 4.4.7-A1 IAltered Residence Slab 3,457 0.730 None 0 180 Existing 4.4.7-A1 JAltered Residence FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Skylight 4.0 0.710 Default 0.60 Default 0 Removed Skylight Altered Residence 2 Skylight 4.0 0.710 Default 0.60 Default 0 Removed Skylight Altered Residence 3 Skylight 4.0 0.710 Default 0.60 Default 0 Removed Skylight Altered Residence 4 Skylight 6.0 0.710 Default 0.60 Default 0 Removed Skylight Altered Residence 5 Skylight 0.8 0.300 NFRC 0.30 NFRC 0 New Solar Tube Altered Residence 6 Skylight 0.8 0.300 NFRC 0.30 NFRC 0 New Solar Tube Altered Residence 7 Skylight 0.8 0.300 1 NFRC 0.30 NFRC 0 New Solar Tube Altered Residence 8 Skylight 0.8 0.300 NFRC 0.30 NFRC 0 New Solar Tube Altered Residence 9 Skylight 26.4 0.710 Default 0.60 Default 0 Existing Skylight Altered Residence 10 Skylight 10.8 0.710 Default 0.60 Default 0 Existing Skylight Altered Residence 11 Skylight 19.6 0.710 Default 0.60 Default 0 Existing Skylight Altered Residence 12 Window 13.8 1.040 Default 1 0.76 Default 25 Existing single Non Metal Clear Altered Residence 13 Window 18.0 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 14 Window 23.4 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 15 Window 48.0 0.460 NFRC 0.39 NFRC 70 Altered Dual Metal Tint Altered Residence 16 Existing 1.040 Default 0.76 Default single Non Metal Clear pre -altered for above (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 None 1.00 7 None 1.00 8 None 1.00 9 None 1.00 10 None 1.00 11 None 1.00 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2012-05-16709:51:05 ID: Page 8 of 15 L, • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/16/2012 OPAQUE SURFACE DETAILS Surface U Insulation Joint Appendix Type Area Factor CavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 60.0 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 18 Window 6.0 1.040 Default 0.76 Default 70 Removed single Non Metal Clear Altered Residence 19 Window 40.0 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 20 Window 40.2 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 21 Window 40.2 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 22 Window 40.2 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 23 Window 40.2 1.040 Default 0.76 Default 70 Existing single Non Metal Clear Altered Residence 24 Window 16.2 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 25 Window 40.2 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 26 Window 40.2 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 27 Window 40.2 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 28 Window 6.3 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 29 Window 15.0 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 30 Window 15.0 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 31 Window 15.0 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 32 Window 4.8 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Right Fin Len H t . LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 EnerqyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Page 9 of 15 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5CF-1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/16/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 7.0 1.040 Default 0.76 Default 160 Removed single Non Metal Clear Altered Residence 34 Window 6.3 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 35 Window 40.2 1.040 Default 0.76 Default 160 Removed single Non Metal Clear Altered Residence 36 Window 32.0 0.530 NFRC 0.46 NFRC 160 New Dual Metal Tint Altered Residence 37 Window 40.2 0.530 NFRC 0.46 NFRC 160 Altered Dual Metal Tint Altered Residence 38 Existing 1.040 Default 0.76 Default single Non Metal Clear pre -altered for above 39 Window 3.0 1.040 Default 0.76 Default 160 Existing single Non Metal Clear Altered Residence 40 Window 6.0 1.040 Default 0.76 Default 250 Removed single Non Metal Clear Altered Residence 41 Window 8.0 1.040 Default 0.76 Default 250 Removed single Non Metal Clear Altered Residence 42 Window 22.1 1.040 Default 0.76 Default 250 Removed single Non Metal Clear Altered Residence 43 Window 8.8 1.040 Default 0.76 Default 250 Removed single Non Metal Clear Altered Residence 44 Window 3.2 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 45 Window 10.5 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 46 Window 10.5 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 47 Window 18.0 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 48Window 40.2 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Overhang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Buq Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 JBug Screen 0.76 EnemyPro 5.1 by EnemySoft User Number.' 6712 RunCode: 2012-05-16T09:51:05 ID: Pae 10 of 15 • L -J • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1511612012 OPAQUE SURFACE DETAILS Surface U Type Area Factor Insulation Joint Appendix Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 40.2 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 50 Window 40.2 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 51 Window 24.0 1.040 Default 0.76 Default 250 Existing single Non Metal Clear Altered Residence 52 Window 13.8 1.040 Default 0.76 Default 295 Existing single Non Metal Clear Altered Residence 53 Window 20.1 1.040 Default 0.76 Default 340 Removed single Non Metal Clear Altered Residence 54 Window 40.2 1.040 Default 0.76 Default 340 Removed single Non Metal Clear Altered Residence 55 Window 16.8 1.040 Default 0.76 Default 340 Removed single Non Metal Clear Altered Residence 56 Window 24.8 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence 57 Window 48.0 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence 58 Window 48.0 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence 59 Window 48.0 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence 60 Window 88.2 1.040 Default 0.76 Default 340 Existing I single Non Metal Clear Altered Residence 61 Window 54.6 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence 62 Window 16.2 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence 63 Window 40.2 1.040 Default 0.76 Default 340 Existing single Non Metal Clear Altered Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Buq Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Buq Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bua Screen 0.76 63 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Pae 11 of 15 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Dr. & Mrs. Carl Highgenboten Building Type ©Single Family ❑Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 1511612012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Existing HVAC Altered Residence 4,657 65,198 1960 Totals 1 01 4,6571 01 0 HVAC SYSTEMS System Name Oty, Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ New ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft N a System Name Pipe Len th Pipe Diameter Insul. Thick. Oty. HP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number.- 6712 Run Code: 2012-05-16T09:51:05 ID: Pae 12 of 15 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Dr. & Mrs. Carl Highgenboten Date 5/16/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of §107111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when's ecified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 15O(e)1A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-05-16709:51:05 ID: Page 13 of 15 • C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Dr. & Mrs. Carl Highgenboten 1511612012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support plafforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Page 14 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Dr. & Mrs. Carl Highgenboten 1511612012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-05-16709:51:05 ID: Page 15 of 15