Loading...
BOTH2015-0006 Title 24r BUILDING ENERGY ANALYSIS REPORT PROJECT: Signature PGA - Recreation Bldg - Outdoor Lighting La Quinta, CA Project Designer: RGA Landscape Architects, INC Palm Desert, CA 92260 760-568-3624 Report Prepared by: Fernando A Rodriguez MRC Engineering, INC 34300 Gateway Drive, Suite 120 ._, Palm Desert, CA 92211 760.340.9005 F ITY OF L ,QUINT _UILDING & SAFETY DEPT. i���tl�zk�a APPROVED. ��G,. i�tcy FOR CONSTRUCTION - Job Number: a' oArEll /6 fojG BY 14047.00 Date: 11/6/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. Ener Pro 6.7 by EnergySoft User Number., 5235 ID: 14047.00 I TABLE OF CONTENTS I Cover Page Table of Contents Form LTO -01-E Outdoor Lighting Form LTO -02-E Outdoor Lighting Controls Form LTO -03-E Outdoor Lighting Power Allowances EnergyPro 6.7 by EnergySoft Job Number ID: 14047.00 User Number: 5235 A 1 2 3 7 10 STATE OF CALIFORNIA OUTDOOR LIGHTING Whv CEC-NRCC-LTO-01-E (Revised 05/15) CALI=ORNIA ENERGY COMMISSION -'%W- CERTIFICATE OF COMPLIANCE NRCC-LTO-01-E Outdoor Lighting (Page 1 of 4) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 Project Address: La Quinta, CA Total Illuminated Hardscape Area 15,162 General Information Phase of Construction: D New Construction ❑ Addition ❑ Alteration Outdoor Lighting Zone (OLZ) ❑ OLZ-1 ❑ OLZ-2 ❑ OLZ-3 ❑ OLZ-4 I have confirmed with the AHJ which OLZ applies to this site. For default lighting zone designations, see Title 24 Part 6, §10-114 LIGHTING COMPLIANCE DOCUMENTS (check box for each document included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to he Nonresidential Manual published by the California Energy Commission. m NRCC-LTO-01-E Certificate of Compliance Q NRCC-LTO-02-E Outdoor Lighting Controls Certificate of Compliance 10 NRCC-LTO-03-E Outdoor Lighting Power Allowance Certificate of Compliance Summary of Allowed Outdoor Lighting Power Watts 1. 1 Sum Total ALLOWED Outdoor Lighting Wattage from NRCC-LTO-03-E, page 1 = 2,989 Complies ONLY if Installed <_ Allowed 2. Sum Total INSTALLED Outdoor lighting Wattage from NRCC-LTO-01-E, page 3 846 Declaration of Required Installation Certificates — Declare by checking all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) D NRCI-LTO-01-E - Must be submitted for all buildings ❑ Field Inspector ❑ NRCI-LTO-02-E - Must be submitted for a lighting control system, or for an ❑ Field Inspector Energy Management Control System (EMCS), to be recognized for compliance. Declaration of Required Certificates of Acceptance — Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) m NRCA-LTO-02-A - Must be submitted for outdoor lighting controls. ❑ Field Inspector CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA OUTDOOR LIGHTING RAM -17 ;EC-NRCC-LTO-01-E (Revised 05/15) CALI =ORNIA ENERGY COMMISSION -N%W' CERTIFICATE OF COMPLIANCE NRCC-LTO-01-E Outdoor Lighting (Page 2 of 4) ProiectName: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 Schedule of luminaires exempt from the outdoor lighting power requirements in §140.7 Name or Symbol I Description of exempt luminaire in accordance with the exemptions Schedule of luminaires exempt from the cutoff requirements in §130.2(b) Name or Symbol I Description of exempt luminaire in accordance with the exemptions Schedule of luminaires exempt from the outdoor lighting control requirements in §130.2(c) Name or Symbol I Description of exempt luminaire in accordance with the exemptions CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA OUTDOOR LIGHTING - CEC-NRCC-LTO-01-E(Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTO-01-E Outdoor Lighting (Page 3 of 4) ProlectName: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 A. OUTDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST - Luminaire Schedule Installed Watts Location Cutoff Field Inspector A B C D E F G H I How wattage was determined � o Name or Complete Luminaire Description 3 g' c 3 3 3 a n - " x „ Primary Function area in which o, v ,, D rn w R Item Tag o, o 0 0 these luminaires are installed °; _ ro CL z `M 0 9' ° of m o'a 0000 ^ 0° N a SD 54w LED 54.0 E ❑ 3 162 Automotive Hardscape ❑ ❑ SD 54w LED 54.0 ❑ 3 162 Walkway < 10' wide ❑: ❑ Sc 9w LED 9.0 ❑ 8 72 Non Sales Canopy ❑ ❑ SD 54w LED 54.0 ❑ 8 432 Pedestrian Hardscape ❑ ❑ SC 9w LED 9.0 ❑ ❑ 2 18 Pedestrian Hardscape ❑ ❑ . ❑ ❑ ❑ ❑_ ❑ ❑ ❑ ❑ ❑ ❑ D ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ ❑ ❑ _ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ -. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 01. ❑ INSTALLED WATTS PAGE TOTAL: Enter sum total of all pages (Sum Total 846 INSTALLED Outdoor lighting wattage) into 846 NRCC-LTO-01-E; Page 1 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA OUTDOOR LIGHTING FC111�r� CEC-NRCC-LTO-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION 'woO"' CERTIFICATE OF COMPLIANCE NRCC-LTO-01-E Outdoor Lighting (Page 4 of 4) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Fernando A Rodriguez Documentation Author Signature: Cempanyi MRC Engineering, INC signature Date: 11/6/2015 Address: 34300 Gateway Drive, Suite 120 CEA Certification Identification (if applicable): City/State/Zip: Palm Desert, CA 92211 r��n—e:760.340.9005 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required tobe in d with the documentation the builder provides to the building owner at occupancy. S0201 &.Age!t Responsible Designer Name: Randall V. Moss P.E. Responsible Designer Signature: �� ' Company: MRC Engineering, Inc. Date Signed: 11/6/2015 Address: 34300 Gateway Drive, Suite 120 L1Cen5e: E.1 3453 City/State/Zip: Palm Desert, CA 92211 Phone: 760.340.9005 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS N�� CEC-NRCC-LTO-02-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION -wQW- CERTIFICATE OF COMPLIANCE NRCC-LTO-02-E Outdoor Lighting Controls (Page 1 of 3) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 The NRCC-LTO-02-E shall be used to document all mandatory outdoor lighting controls that are applicable to the project. Mandatory Outdoor Lighting Control Declaration Statements Check all that apply: ❑ Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with §110.9(a). ❑ Lighting shall be controlled by a lighting control system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with §130.4(b). 0 All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with §130.1 ❑ Part -Night Outdoor Lighting Controls, as defined in Section 100.1(b), shall meet the requirements in Section 110.9(b)5 ❑ All outdoor incandescent luminaires rated over 100 watts, determined in accordance with Section 130.0(c), shall be controlled by a motion sensor. ❑ All outdoor luminaires rated for use with lamps greater than 150 lamp watts, determined in accordance with Section 130.0(c), shall comply with Backlight, Uplight, and Glare (collectively referred to as "BUG") in accordance with Section 130.2(b) Z All installed outdoor lighting shall be controlled by a photocontrol or outdoor astronomical time -switch control in accordance with Section 130.2(c)1 0 All installed outdoor lighting shall be circuited and independently controlled from other electrical loads by an automatic scheduling control in accordance with Section 130.2(c)2 ❑ All installed outdoor lighting, where the bottom of the luminaire is mounted 24 feet or less above the ground, shall be controlled with automatic lighting controls in accordance with Section 130.2(c)3 ❑ For Outdoor Sales Frontage, Outdoor Sales Lots, and Outdoor Sales Canopies lighting, an automatic lighting control in accordance with Section 130.2(c)4 ❑ For Building Facade, Ornamental Hardscape and Outdoor Dining lighting, an automatic lighting control in accordance with Section 130.2(c)5 El Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with §130.4.(a). Outdoor lighting controls shall comply with the applicable requirements of Section 130.2(c) and Reference Nonresidential Appendix NA7.8 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 r 0 cn Fail X 0 0 0 ❑' 0 O 0 0° M' aI 0 0 C O 01 Field Inspector O Z N d O L) U N W U Z o Q t J CL O ^ � C U a�O J W U LL�° tow Pass ° ❑. NO O ❑ C rn ❑ d O 1j. ❑ t ❑ ❑ Q J 006 Q J ❑ 00, U LL O E' L W L Z a a F w U) 0 U O ° ' Ln 0 N 2 Fail X 0 0 0 ❑' 0 0 0 O M' O 0 0 0.0 01 Field Inspector O u.. Pass ° ❑. ❑. ❑ ❑ ❑ ❑ ❑. 1j. ❑ t ❑ ❑ ❑ a ❑ ❑. ❑ 00, ✓ it Acceptance ' Te;t Required — §130.2(c)5 a ai - Y CL E x §130.2(c)4 Yv X . W en W c , nom`, c7 §130.2(c)3 E c O °1 U O a LL §130.2(c)2 -o CL C m M. Ln m LU §130.2(c)1 J — ' u o §130.2(a) Z - O W UC a Z J W y L U. _ O C i L C p C °0 fG U C C Y N L ° 3 — 00 G1 LLJ w40- T a C U) H H J n E U O W OC a v .o v H ♦ O V�1 VI C �_ Z O ba _ CO m o .o ,�. Y O V ,C—, ami o m aci Co C7 L J a E U ~ w z Q Z O J a+ O w _° O N O S-0 O o D O � �U U 0. O O Q O cgs? C C_ U E i Z • m Ln 0 N 2 STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CEC-NRCC-LTO-02-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTO-02-E Outdoor Lighting Controls (Page 3 of 3) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Fernando A Rodriguez Documentation Author Signature: Company: MRC Engineering, INC Signature Date: 11/6/2015 Address: 34300 Gateway Drive, Suite 120 CEA Certification Identification (if applicable): City/state/Zip. Palm Desert, CA 92211 Phone: 760.340.9005 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Ce ' ' to of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Randall V. Moss P.E. Responsible Designer Signature: Company. MRC Engineering, Inc. r Date signed` 11/6/2015 Address. 34300 Gateway Drive, Suite 120 Ucense: EA 3453 City/State/Zip: Palm Desert, CA 92211 Phone: 760.340.9005 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 = OF CALIFORNIA TDOOR LIGHTING POWER ALLOWANCESI I IRCC-LTO-03-E Revised 05/15 CALIFORNIA ENERGY COMMISSION TIFICATE OF COMPLIANCE NRCC-LTO-03-E door Lighting Power Allowances (Pagel of 4) I I Name: Signature PGA - Recreation Bldg - Outdoor Lighting I Date Prepared: 11/6/2015 I OUTDOOR LIGHTING POWER ALLOWANCE SUMMARY Area Wattage Allowance (AWA) eneral Hardscape Lighting Power Allowance (Site Total from Section B of NRCC-LTO-03-E) 1. 2,917 dditional Specific "use it or lose it" Lighting Power Allowances listed in each of these cells shall be identical to total allowed watts A B !rmined in Section C-1 to C-4 of NRCC-LTO-03-E. E PER APPLICATION PER UNIT LENGTH PER HARDSCAPE AREA PER SPECIFIC AREA G from Section C-1 (SALES FRONTAGE) (ORNAMENTAL LIGHTING) from Section C-4. 1 from Section C-2 from Section C-3 AWA Per Square Foot AWA (B x C) 0 + 0 + 0 + 72 = 2. 72 Am Total ALLOWED Outdoor Lighting Wattage (add rows 1 and 2) 3. 2,989 IENERAL HARDSCAPE LIGHTING POWER ALLOWANCE FROM TABLE 140.7-A Area Wattage Allowance (AWA) Linear Wattage Allowance (LWA) Initial Wattage Allowance (IWA) Total General Hardscape Lighting Allowance A B C D E F G H 1 Illuminated Name of area Hardscape Area AWA Per Square Foot AWA (B x C) Perimeter Length of General Hardscape LPA per Linear Foot LWA (E x F) 175 369 IWA (Watts) 770 U 0 TOTAL D+ G + H 'king lkway —2-9T-0.600 0.600 256 -dscape 8,154 0.090 734 615 1,103 2,917 gilding Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CEC-NRCC-LTO-03-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTO-03-E Outdoor Lighting Power Allowances (Page 2 of 4) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 C. ADDITIONAL "USE IT OR LOSE IT" OUTDOOR LIGHTING POWER ALLOWANCES FOR SPECIFIC APPLICATIONS ❑ The additional specific outdoor lighting power allowance shall be the smaller of the allowed lighting power or the actual lighting power used. ❑ Use Outdoor Lighting Zone (OLZ) that is documented on page 1 of NRCC-LTO-01-E to calculate the specific wattage allowances. C-1. WATTAGE ALLOWANCE PER APPLICATION —'I able 14U./-13 ❑ Available only for qualifying locations, which include Building Entrances or Exits; Primary Entrances to Senior Care Facilities, Police Stations, Hospitals, Fire Stations, and Emergency Vehicle Facilities; Drive Up Windows; Vehicle Service Station Uncovered Fuel Dispenser ❑ If more than one luminaire type is used per location, use multiple rows for that location A B C D E F G H I J Name of Location for which allowance is claimed ALLOTTED WATTS DESIGN WATTS Number of qualifying locations Wattage Allowance per qualifying location Allotted Watts (B x C) Luminaire Code or Symbol Luminaire Description Luminaire Quantity Watts per luminaire Design Watts (G x H) Allowed Watts (smaller of D or 1) Sum total allowance per application on this site: 0 C-2. WATTAGE ALLOWANCE PER UNIT LENGTH (Sales Frontage) from Table 140.7-13 ❑ If more than one luminaire type is used per location, use multiple rows for that location A B I C D E F G. H I J Name of Location for which allowance is claimed ALLOTTED WATTS DESIGN WATTS Linear feet of Sales Frontage Wattage Allowance per linear foot Allotted Watts (B x C) Luminaire Code or Symbol Luminaire Description Luminaire Quantity Watts per luminaire Design Watts (G x H) Allowed Watts (smaller of D or 1) Sum total allowance for sales frontage on the site:. 0 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CEC-NRCC-LTO-03-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION -qWW- CERTIFICATE OF COMPLIANCE NRCC-LTO-03-E Outdoor Lighting Power Allowances (Page 3 of 4) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 C-3. WATTAGE ALLOWANCE PER SQUARE FOOT OF HARDSCAPE AREA (Ornamental Lighting) — Table 140.7-13 ❑ Allowance for the total site illuminated hardscape area. Luminaires qualifying for this allowance shall be rated for 100 watts or less as determined in accordance with Section 130.0(c), and shall be post -top luminaires, lanterns, pendant luminaires, or chandeliers. ❑ If more than one luminaire type is used per location, use multiple rows for that location A B I C D E F G H I J Name of area for which ornamental allowance is claimed ALLOTTED WATTS DESIGN WATTS Wattage Allotted Square feet of Allowance per Watts Hardscape square foot (B x C) Luminaire Code or Symbol Luminaire Description Luminaire Quantity Watts per luminaire Design Watts (G x H) Allowed Watts (smaller of D or 1) Sum total allowance for ornamental lighting on the site:. 0 C-4. WATTAGE ALLOWANCE PER SQUARE FOOT OF SPECIFIC AREA- Table 140.7-13 ❑ Allowances for Building Facades; Outdoor Sales Lots; Vehicle Service Station Hardscape; Vehicle Service Station Canopies; Sales Canopies; Non -sales Canopies; Guard Stations; Student Pick-up/Drop-off zone: Outdoor Dining; Special Security Lighting for Retail Parking and Pedestrian Hardscape. ❑ If more than one luminaire type is used per location, use multiple rows for that location A B I C D E F G H I J Name of Location for which allowance is claimed ALLOTTED WATTS DESIGN WATTS Illuminated Area of Application Wattage Allowance per square foot Allotted Watts (B x C) Luminaire Code or Symbol Luminaire Description Luminaire Quantity Watts per luminaire Design Watts (G x H) Allowed Watts (smaller of D or 1) Outdoor Patio 403 0.408 164 SC 9w LED 8 9.0 72 72 Sum total allowance for specific area on the site: 72 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CEC-NRCC-LTO-03-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE - NRCC-LTO-03-E Outdoor Lighting Power Allowances (Page 4 of 4) Project Name: Signature PGA - Recreation Bldg - Outdoor Lighting Date Prepared: 11/6/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Fernando A Rodriguez Documentation Author Signature: Company: MRC Engineering, INC signature Date: 11/6/2015 Address: 34300 Gateway Drive, Suite 120 CEA Certification Identification (if applicable): City/State/Zip: Palm Desert, CA 92211 Phone: 760.340.9005 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on. this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Complia required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Randall V. Moss P.E. Responsible Designer Signature: Company: MRC Engineering, Inc. Date signed: 11/6/2105 Address` 34300 Gateway Drive, Suite 120 License: E. 13453 City/state/zip: Palm Desert, CA 92211 Phone: 760.340.9005 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 NdIRIC UI -E V-1 -