CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation DatelTime: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis Input File Name: 64386 Bradshaw Remodel.ribdl6x
CF1R-PRF-01 ,
Page 1 of 10
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Bradshaw Remodel
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ftZ-yr)
03
Project Location
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2017
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2016.2.1 (695)
08
Climate Zone CZ15
09
Software Version EnergyPro 7.1
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftZ) 4838
15
Number of Zones 2
16
Slab Area (ftZ) 4838
17
Number of Stories 1
18
Addition Cond. Floor Area 213
19
Natural Gas Available Yes
20
Addition Slab Area (ftZ) 213
21
Glazing Percentage (%) 17.8%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance* _
02 This building incorporates features that require fieldaest ng•'pnd/or7verIficafion by a certifi d.HERSrate7r fieri a supervision of a CEC-approved HERS provider.
03 This building incorporates one o_ r3more Sp c a1 -F at es~shown below Ir 5 a 4"%00
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Window overhangs and/or fins
Registration Number: 217-Po10179848A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.32
3.13
0.19
5.7%
Space Cooling
99.67
96.45
3.22
3.2%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
3.70'
3.70
0.00
0.0%
ehoW11 ltaic Offcot
0.00
0.00
----
Compliance Energy Total
106.69
103.28
3.41
3.2%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Window overhangs and/or fins
Registration Number: 217-Po10179848A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:54, Wed, May 24, 2017
Input File Name: 64386 Bradshaw Remodel.ribdl6x
CFI R -PRF -01
Page 2 of 10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• --None --
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
.02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Bradshaw Remodel
4838
1
5
2
0
1
ZONE INFORMATION 1 i '` l i �t� _ 17 I f`� l `-) 7((7 1 r---,,
01
02 ��
il1\ i lt51 —\
`I
1 1 03 I F_ ;
, 1104 ._
r/�
r1
1 f 165 11
06
07
Zone Name
Zone Typ
�.,.�+� �v i.I ��� 'r. -w. -r w+
HVAC System�Name
3 K' f Y
Zone Floor Areal
!t2) {
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Addition
Conditioned
Split Systeml
213
8
DHW Sys 1
n/a
Existing
Conditioned
Split Systeml
4625
8
DHW Sys 1
n/a
Registration Number: 217-PO10179845A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis
Input File Name: 64386 Bradshaw Remodel.ribdl6x
CF1 R -PRF -01
Page 3 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
01
02
03 04
05
06
07
08
09
10
Name
Zone
Construction Azimuth
Orientation
Window & Door
Gross Area (ft) Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
Exterior Wall E
Addition
R-15 Wall 90
Left
124.2
22
90
New
N/A
Exterior Wall S
Addition
R-15 Wall 180
Back
209
22
90
New
N/A
Exterior Wall W
Addition
R-15 Wall 270
Right
124.2
12
90
New
N/A
Roof
Addition
R-38 Roof Attic
213
New
N/A .
Exterior Wall N
Existing
R-19 Wall 0
Front
1201.7
481.92
90
Existing
No
Exterior Wall E 2
Existing
R-19 Wall 90
Left
124.2
89.5
90
Existing
No
Exterior Wall S 2
Existing
R-19 Wall 180
Back
648
147
90
Existing
No
Exterior Wall W 2
Existing ,
R-19 Wall 270
Right
1186
115.5
90
Existing
No
Interior Surface
Existing —_Garage_
R-19 Wall
445.4
0
Existing
No
Roof 2
Existing
R-30 Roof Attic
4625
Existing
No
Exterior Wall E 3
_Garage_
�_ , R-0 Wall ,�, r- _1 ,.90„ r.� —, .,Left
n 233
21.3
90
New
N/A
Exterior Wall S 3
CR01Nal1f( 4 -, ,180
Backf
X213
144
90
New
N/A
Interior Surface E
_Garage_
Garage -.,,r
`�� R;O Wall1 ��r l ti
! 233 ��, .�
0
New
N/A
Roof 3
Garage �
q_ A R -O Roof.Attic4r- p-% ps
t \ O l4/1
7'1 495 tib
New
N/A
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Garage_
Attic Garage Roof Cons
Ventilated
3
0.1
0.85
No
No
Existing
No
Attic Addition
Attic RoofAddition
Ventilated
3
0.2
0.75
Yes
Yes
New
No
Attic Existing
Attic RoofExisting
Ventilated
1 3
1 0.1
1 0.85
1 Yes
I No
I Existing
I No
Registration Number: 217-PO10179845A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis
Input File Name: 64386 Bradshaw Remodel.ribdl6x
CF1 R -PRF -01
Page 4 of 10
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplier
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
4056 SH
Exterior Wall E (Left -90)
----
----
1
22.0
_ 0.34 _
0.25
Insect Screen (default)
New
N/A
(2) 2056 SH
Exterior Wall S (Back -180)
4.0
5.0
1.1
22.0
0.34
0.25
Insect Screen (default)
New
N/A
2060 SH
Exterior Wall W (Right -270)
----
----
1
12.0
0.34
0.25
Insect Screen (default)
New
N/A
(2) 2060 SH
Exterior Wall N (Front -0)
4.0
6.0
1
24.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 2016 FX
Exterior Wall N (Front -0)
4.0
6.0
0.25
6.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 6016 FX
Exterior Wall N (Front -0)
4.0
6.0
0.75
18.0
0.35
0.25
Insect Screen (default)
Existing
No
6060 FX
Exterior Wall N (Front -0)
4.0
6.0
0.25
6.0
0.35
0.25
Insect Screen (default)
Existing
No
6060 SL
Exterior Wall N (Front -0)
6.0
6.0
1
36.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 12010 SLD
Exterior Wall N (Front -0)
24.0
10.0
1
240.0
0.35
0.25
Insect Screen (default)
Existing
No
16080 SLD
Exterior Wall N (Front -0)
24.0
10.0
0.533
127.9
0.35
0.25
Insect Screen (default)
Existing
No
3080 FR DR
Exterior Wall N (Front -0) -,
----
. _ --_ ..
_ 1, , X24.0
1 X0.35
0.25
Insect Screen (default)
Existing
No
3080 FR DR 2
Exterior Wall E 2 (Left -90)!
C--_3.0
I 8.0 � -
-)1 1
24.0
0.35=� ;
0.251
Insect Screen (default)
Existing
No
3016 FX
Exterior Wall -E 2 (Left-90)�-_ (�3:o'
�.._1.5L _
f i 1 i
4.5 ,
, 0.35 `0:251 ,
Insect Screen (default)
Existing
No
3050 SH
Exterior Wall E2 (Left -90)
s_, ---�-� �---- p • -1 �,
X15,0-
•-0.35 --
0.25
Insect Screen (default)
Existing
No
(2) 3060 SH
Exterior Wall E 2 (Left -90) "
``"--- ----
` 1' ""
36.0
`0.35 `'
0.25
Insect Screen (default)
Existing
No
2050 SH
Exterior Wall E 2 (Left -90)
----
----
1
10.0
0.35
0.25
Insect Screen (default)
Existing
No
6080 SLD
Exterior Wall S 2 (Back -180)
----
----
1
48.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 2060 FX
Exterior Wall S 2 (Back -180)
4.0
6.0
1
24.0
0.35
0.25
Insect Screen (default)
Existing
No
2040 SH
Exterior Wall S 2 (Back -180)
----
----
1
8.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 3056 SH
Exterior Wall S 2 (Back -180)
----
----
1
33.0
0.35
0.25
Insect Screen (default)
Existing
No
1640 FX
Exterior Wall S 2 (Back -180)
----
----
1
6.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 3060 SH 2
Exterior Wall W 2 (Right -270)
----
----
1
36.0
0.35
0.25
Insect Screen (default)
Existing
No
(3) 2060 SH
Eidorior. Wall W 2 (flight -270)
----
__--
1
38.0
0.35
u.25
Insect Screen (ae6ult)
Existing
No
5050 SL
Exterior Wall W 2 (Right -270)
----
----
1
25.0
0.35
0.25
Insect Screen (default)
Existing
No
2040 SH 2
Exterior Wall W 2 (Right -270)
----
----
1
8.0
0.35
0.25
Insect Screen (default)
Existing
No
(2) 2016 FX 2
Exterior Wall W 2 (Right -270)
1
6.0
0.35
0.25
Insect Screen (default)
Existing
No
3016 FX 2
Exterior Wall W 2 (Right -270)
1
4.5
0.35 1
0.25
Insect Screen (default)
Existing
No
Registration Number: 217-P010179845A-000-000-0000000-0000 Registration DatelTime: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis
Input File Name: 64386 Bradshaw Remodel.ribdl6x
CF1 R -PRF -01
Page 5 of 10
OPAQUE DOORS
01
02
03 04
05
06
Name
Side of Building
Area (ft2) U -factor
Status
Verified Existing Condition
3680 SC Door
Exterior Wall S 2
28.0 0.50
Existing
No
OVERHANGS AND FINS
01
02 03
04
05
06
07
08 09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up DistL
Bot Up
Depth
Top Up Dist R
Bot Up
(2) 2056 SH
2 0.1
2
2
0
0
0 0
0
0
0
0
0
(2) 2060 SH
8 0.1
8
8
0
0
0 0
0
0
0
0
0
(2) 2016 FX
8{ 0.1
8
8
0
0
0 0
0
0
0
0
0
(2) 6016 FX
8` ,7 ', 0.1
8
8
0
0
0 0
0
0
0
0
0
6060 FX
8 0.1
8
8
0
0
0 0
0
0
0
0
0
6060 SL
`. 10 2
10
10
0
0
0 0
0
0
0
0
0
(2) 12010 SLD
10 ---'2
A 10�
X10
[ 0 *
0
01 { r 0�
0
0
0
0
0
16080 SLD
j 10 i � \\ 2
� � 10`0
11 110,_ ,
L-0 FA\1
11 0")
Oil 1: l
0
0
0
0
0
3080 FR DR 2
10 2
00
�0
0 f
�� 0� �,. 0
0
0
0
0
0
3016 FX
10 2
10
if -*10"'x'
t0 f--1
'fro V
# 0"�" 01�
0
0
0
0
0
(2) 2060 FX
2 0.1
2
2
0
0
0 0
0
+ 0
0
0
0
Registration Number: 217-Po10179845A-000-000-0000000-0000 Registration Daterrime: 2017-06-01 11:32:20 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis
Input File Name: 64386 Bradshaw Remodel.ribd16x
CFI R -PRF -01
Page 6 of 10
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/ Frame: no insul. / 2x4
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofAddition
Attic Roofs r'
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
i
Inside Finish: Gypsum Board
\
Cavity / Frame: R-15 / 2x4
• Sheathing / Insulation: R6 Sheathing
R-15 Wall
Exterior Walls
Wood Framed Wall
2x4 @-16 in. O,C. 1
R 16
0.056
Exterior Finish: 3 Coat Stucco
Ceilings (below l
(�
(�
Inside Finish: Gypsum Board
Cavity/ Frame: R-9.1 / 2x4
R-38 Roof Attic
C
Framed
attic) !
• Wood Ceiling
2x4,@-24,
m; O:C.
T R 38rq_oz5
Over Ceiling Joists: R-28.9 insul.
f
y
Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top -Chord of Roof Truss @'24
v
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-19 / 2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
0.072
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Ceiling Joists: R-20.9 insul.
• Inside Finish: Gypsum Board
• Cavity / F/ame: R-19 / 2x6
R-19 Walll
Interior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
f: 19
0.067
Other Side Finish: Gypsum Board
Registration Number: 217-Po10179645A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date(Time: 2017-06-01 11:32:20
Report Version - CF1 R-05092017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis
Input File Name: 64386 Bradshaw Remodel.ribd16x
CFI R -PRF -01
Page 7 of 10
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Addition
213
45.75
None
0.8
No
New
No
Slab -on -Grade 2
Existing
4625
356.45
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (Qll) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
t FQ9
10
11
Heating System
Cooling System
Solar
Tank
Energy
•`
Tank Insulation
System Type
Number of
Fraction
Name
Verified Existing
Name
System Type
I Distribution Typed-� ��
y
-.��WatprHeater
Heaters
(%)
Status
Condition
DHW Sys 1
DHW ' -`
�� Standard } �-
�� 1DHW,Heater 1 1 f �
l � 1
Annual
Existing
No
WATER HEATERS '%\er..1 U '11� A U 1,.): U C=/ I/ U U U "' U
01
02
�` 03
04
O5_"
0;6}
� bt C
3 V 08 �,,,�
t FQ9
10
11
Heating System
Cooling System
Distribution
System
Tank
Energy
Tank Insulation
System Type
Name
Tank Location or
Name
Heater
Fan
System
Number
Volume
Factor or
Input
R -value
Standby Loss /
Yes
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(InUExt)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small
Instantaneous
1
0.2
0.82 EF
199900 Btu/hr
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
System
Name
System Type
Name
Ducted
Name
Ducted
Fan
System
Floor Area
Served
Status
Verified Existing
Condition
Split Systeml
Other Heating and
Cooling System
Heating
Component 1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan
1
4838
New
No
Registration Number: 217-Po10179845A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis
Input File Name: 64386 Bradshaw Remodel.ribd16x
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
CF1 R -PRF -01
Page 8 of 10
HVAC - COOLING UNIT TYPES
01
02
03
04 05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
2
12.2
14
Zonally Controlled
Single Speed
Cooling Component
1 -hers -cool
HVAC COOLING - HERS VERIFICATIONx
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
\ Required
350
Required
Not Required
Required
HVAC COOLING - HERS VERIFICATION -x (( ��
01
1 �',: 02 ��..i
`�i r U
U t03 U' 1.1
#i"(
U
n 04J U
aQ 05
06
Name
H 1�
Verified Airflow f i 1G
R c► t} C)
tl 1 Airflow Targe a
�► - F'"% T- F
4r Ver ed -EE Y
s Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
System 1
(Ventilated and
specified)
6.0
Attic
Attic
None
Existing
No
N/A
Unventilated)
HVAC - FAN SYSTEMS & HERS VERIFICATION
01
02 03 04
Name
Type Fan Power (Watts/CFM) HERS Verification
HVAC. Fan 1
Single Speed PSC Furnace Fan 0.58 Required
Registration Number: 217-Po10179845A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2017-06-01 11:32:20
Report Version - CF1 R-05092017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation Date/Time: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis Input File Name: 64386 Bradshaw Remodel.ribdl6x
CFI R -PRF -01
Page 9 of 10
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%a) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: 217-Po10179845A-000-000-0000000-0000 Registration Datelrime: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF 1 R-0509201 7-695 Report Generated at: 2017-05-24 14:55:26
`�
li} ��)
Registration Number: 217-Po10179845A-000-000-0000000-0000 Registration Datelrime: 2017-06-01 11:32:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF 1 R-0509201 7-695 Report Generated at: 2017-05-24 14:55:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Bradshaw Remodel Calculation DatefTime: 14:54, Wed, May 24, 2017
Calculation Description: Title 24 Analysis Input File Name: 64386 Bradshaw Remodel.ribdl6x
CFI R -PRF -01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Roham Naderi
Company:
Signature Date:
Gouvis Engineering Consulting Group
2017-05-31 15:46:24
Address:
CEA/HERS Certification Identification (If applicable):
4400 Campus Dr
City/State/Zip:
Phone:
Newport Beach, CA 92660
949-752-1612
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications
identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. ,
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted
to,the enforcement agency, for approval.with this building permit application.
Responsible Designer Name:
',
L Po)
1 L I � !
Responsi
rlIble besigner Signatu
�Ce r h.10
Kell Bradshaw . "�
? i f r7
I I ,
Company: !
p
Date. Signed: A'
Bradshaw Construction Inc
2017-06-01 11:32:20
Address:
License:
46248 Roudel Lane
n/a
City/State/Zip:
Phone:
La Quinta, CA 92253
760-347-4246
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-Po10179845A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 11:32:20
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695
❑ ❑
HERS Provider: CaICERTS inc.
Report Generated at: 2017-05-24.14:55:26
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply.
fOriainal 08/20161
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-13 for compliance and must be caulked and/or weatherstried.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043.
Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or LI -factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.'
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(8)1:
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U -factor of 0.58; or the weighted averse LI -factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
F§1 .0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at lea3t 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.06)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the extarior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from --he storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water )ipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade rust be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 11-0.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, ecuipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor servfte. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units mLst include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 1113(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by tha Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California' Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Met3l and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or hither if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. 0.)enings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the Toss -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requiremp.nts for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements fx: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moistur--, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminim, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inne _ core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification -and diagnostic testing, in
accordance with § 150.0 m 11and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 f3et in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the cesign, installation, efficiency,
pressure drop, and labeling requirements of § 150.0 m 12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal ccoling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zine for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(0):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)tA:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of :he following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; arrl must not use electric
resistance heating.'
§ 110.4(b)l:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter End the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must -neet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(:), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor anc do not contain a luminaire or
§ 150.0(k)l B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a di nmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8 ?016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must hava an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fan! must be rated to consume no
§ 150.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lyhts do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacterer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings anc must contain lamps that comply
§ 150.0(k)l G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as spe:ified in Reference Joint Appendix
JA8.'
§ 150.0(k)l H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply wth NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § '50.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(f); and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.*
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a totai of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
ower as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential grages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
re uirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".