Loading...
05-4333 (SFD) Title 24�.w TITLE 24 REPORT Title 24 Report for: Epic Enterprises Cortez Lane La Quinta, CA 92243 Project Designer: Gabriel Lujan & Associates 45-175 Panorama Drive, #A Palm Desert, CA 92260 (760) 578-8545 Report Prepared By CITY OF LA QUINTA Tim Scott BUILDING & SAFETY DEPT. H & H Air Conditioni g APPROVED 74-991 Joni Drive #2 FOR CONST UCTION Palm Desert, CA 92260- 043 (760) 340-3088 I DAT:Sj _ Br Job Number: III FEB 0 2 2006 D Date: 1/4/06 �he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. t This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: User Number: 5533 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1R Mandatory Measures Summary 8 Form WS -5R Residential Kitchen Lighting 10 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 14 Room Heating Peak Loads 17 Room Cooling Peak Loads 20 ' EnergyPro 4.0 by EnergySoft Job Number: User Number: 5533 Certificate Of Compliance': Residential (Part 1 of 3) CF -1 R *j -ct Tif-- pec Enterprises 1/4/06 -Date Cortez Lane La Quinta Project Address Building Permit # H & H Air Conditioning (760) 340-3088 Plan Check/Date -Documentation Author Telephone EnergyPro 15 Field Check/Date ! '� Compliance Mefhod Clirnateons -- Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.56 1.53 0.03 0 Space Cooling 57.97 8.32 54.23 8.15 3.74 0.17 Not Valid for permit Fans Domestic Hot Water 8.80 11.69 -2.89 applications submitted on or Pumps 0.00 0.18 -0.18 after 01/23/06 because Totals 76.65 75.79 0.86 Energy Budget is based on Percent better than Standard: 106 0.069 1.1% SEER 10. Building Type: n Single Family [] Addition Total Conditioned Floor Area: 2,916 ft2 ❑ Multi Family [] Existing + Add/Alt Building Front Orientation: (North) 0 deg Fuel Type: Natural Gas Fenestration: Area: 485 ft 2 Avg. U: 0.53 Ratio: 16.6% Avg. SHGC: 0.59 WILDING ZONE INFORMATION Zone Name Floor Area Volume HVAC -2 HVAC -3 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 2,916 ft2 Average Ceiling Height: 10.0 ft Number of Dwelling Units: 1.00 17 Number of Stories: 1 Wood # of Thermostat Vent Units Zone Type Type Hgt. Area 613 6.130 0.21 Sleeping SleepingStat 2 n/a 1,294 12,940 0.44 LivingLivingStat 2 n/a 1,009 10,090 0.35 Sleeping SleepingStat 2 n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Gains Condition Tilt Y / N Status JA IV Reference Location / Comments Roof Wood 613 0.028 R-38 R-0.0 0 22 Wall Wood 64 0.069 R-21 R-0.0 17 90 Wall Wood 30 0.069 R-21 R-0.0 90 90 Wall Wood 106 0.069 R-21 R-0.0 180 90 Wall Wood 190 0.069 R-21 R-0.0 270 90 Wall Wood 146 0.069 R-21 R-0.0 287 90 Roof Wood 1,294 0.028 R-38 R-0.0 0 22 Wall Wood 170 0.069 R-21 R-0.0 0 90 Door None 48 1.450 None R-0.0 0 90 Wall Wood 39 0.069 R-21 R-0.0 17 90 Door None 21 1.450 None R-0.0 17 90 Wall Wood 40 0.069 R-21 R-0.0 90 90 Wall Wood 227 0.069 R-21 R-0.0 180 90 Wall Wood 40 0.069 R-21 R-0.0 270 90 Wall Wood 60 0.069 R-21 R-0.0 287 90 Roof Wood 1,009 0.028 R-38 R-0.0 0 22 Wall Wood 125 0.069 R-21 R-0.0 0 90 Wall Wood 240 0.069 R-21 R-0.0 75 90 Wall Wood 361 0.069 R-21 R-0.0 90 90 Wall. Wood 205 0.069 R-21 R-0.0 180 90 Wall Wood 227 0.069 R-21 R-0.0 270 90 New New 02-A28 09-A6 _ Master Suite _ Master Suite New New 09-A6 09-A6 Master Suite Master Suite New 09-A6 Master Suite New New 09-A6 02-A28 Master Suite Great/Kitchen/Dining New 09-A6 Great/Kitchen/Dining _ New 28-A1 , Great/Kitchen/Dining New 09-A6 __ Great/Kitchen/Dining T New 28-A1 Great/Kitchen/Dining New 09-A6 _ _ Great/Kitchen/Dining.` - New New 09-A6 09-A6 Great/Kitchen/Dining__ _ Great/Kitchen/Dining New 09-A6 Great/Kitchen/Dining New New 02-A28 09-A6 Master 2/Bdrm 2/Guest Master 2/Bdrm 2/Guest New 09-A6 Master 2/13drm 2/Guest New 09-A6 Master 2/Bdrm 2/Guest New New 09-A6 09-A6 Master 2/13drm 2/Guest Master 2/13drm 2/Guest I Run Initiation Time: 01/04/06 14:13:57 Run Code: 1136412837 1 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:3 of 22 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R plc Enterprises 1/4/06 oject Title -Date FENESTRATION SURFACF-5i True Cond. Location/ { # Type Area LI -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1 Window Rear (South) 64.0 0.530 NFRC 0.59 NFRC 180 90 New Double Metal Tinted Master Suite 2 Window Right (West) 12.5 0.530 NFRC 0.59 NFRC 270 90 New Double Metal Tinted Master Suite 3 Window Right (West) 12.5 0.530 NFRC 0.59 NFRC 270 90 New Double Metal Tinted Master Suite 4 Window Right (West) 30.0 0.530 NFRC 0.59 NFRC 287 90 New Double Metal Tinted Master Suite 5 Window Right (West) 4.0 0.530 NFRC 0.59 NFRC 287 90 New Double Metal Tinted _ Master Suite 6 Window Front (North) 25.0 0.530 NFRC 0.59 NFRC 0 90 New Double Metal Tinted Great/Kitchen/Dining 7 Window Front (North) 2.0 0.720 NFRC 0.39 NFRC 0 90 New Glass Block _ Great/Kitchen/Dining 8 Window Rear (South) 64.0 0.530 NFRC0.59 NFRC 180 90 New Double Metal Tinted Great/Kitchen/ ining 9 Window Rear (South) 64.0 0.530 NFRC 0.59 NFRC 180 90 New Double Metal Tinted Great/Kitchen/Dining 10 Window Rear (South) 20.0 0.530 NFRC 0.59 NFRC 180 90 New Double Metal Tinted Great/Kitchen/Dining 11 Window Front (North) 25.0 0.530 NFRC 0.59 NFRC 0 90 New Double Metal Tinted Master 2/Bdrm 2/Guest 12 Window Left (East) 25.0 0.530 NFRC 0.59 NFRC 90 90 New Double Metal Tinted Master 2/Bdrm 2/Guest 13 Window Left East) 30.0 0.530 NFRC 0.59 NFRC 90 90 New Double Metal Tinted Master 2/Bdrm 2/Guest- 14 Window Left (East) 4.0 0.530 NFRC 0.59 NFRC 90 90 New Double Metal Tinted Master 2/Bdrm 2/Guest 15 Window Rear (South) 30.0 0.530 NFRC 0.59 NFRC 180 90 New Double Metal Tinted Master 2/Bdrm 2/Guest- 16 Window Right (West) 48.0 0.530 NFRC 0.59 NFRC 270 90 New Double Metal Tinted Master 2/Bdrm 2/Guest 17 Window Right (West) 25.0 0.530 NFRC 0.59 NFRC 270 90 New Double Metal Tinted Master 2/Bdrm 2/Guest 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Insulation Overhang Left Fin Right Fin t # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 -Bug Screen 0.76 8-0-8-0 Master Suite 6-0 0-1-6-0 6-0 r 2 Bug Screen 0.76 lab Perimeter 61 one No Insulation 26-A1 New Great/Kitchen/Dining - Bug Screen 0.76 None No Insulation 26-A1 New Great/Kitchen/Dining -- 102 Bug Screen 0.76. New Master 2/Bdrm 2/Guest 5 Bug Screen 0.76 6- Bug Screen 0.76 7 Bug Screen 0.76 -87 Bug Screen 0:76- --8-0 -8.0 -8"0 -0-1 -8-0 -8-0 9 Bug Screen 0.76 8.0 8.0 8.0 0.1 8.0 8.0 10 Bug Screen 0.76 J "IT Bug Screen . 016 -- t 1-2 Bug Screen -0:76- 1 13 Bug Screen -- 14 Bug Screen 0.7fi 15 Bug Screen 0.76 -- -" i 1-6 Bug Screen -0:76- 8.0 6.0 6.0 0.1 6.0 6.0 - _ --- 17 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (sf) (in.) Cap. Cond. R -Val. Condition Location/ JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 56 None No Insulation 26-A1 New Master Suite Slab Perimeter 20 None No Insulation 26-A1 New Master Suite lab Perimeter 61 one No Insulation 26-A1 New Great/Kitchen/Dining - lab Perimeter 23 None No Insulation 26-A1 New Great/Kitchen/Dining Slab Perimeter 102 None No Insulation 26-A1 New Master 2/Bdrm 2/Guest Run Initiation Time: 01/04/06 14:13:57 Run Code: 1136412837 tnergyPro 4.0 by Fnergybott User Number: 5533 Job Number: Page:4 of 22 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R 0iFo- pic Enterprises 1/4/06 ject Title Date True Cond. Location/ # Type Area LI -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments r 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC. Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. _Hgt s — t t — THERMAL MASS FOR HIGH MASS DESIGN I Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 29 None No Insulation 26-A1 New Master 21Bdrm 2/Guest Run Initiation Time: 01/04/06 14:13:57 Run Code: 1136412837 -EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:5 of 22 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R plc Enterprises Tank Energy Standbyl Tank Insul. # in Input Cap. 1/4/06 roject Title Syst. (Btu/hr) (gal) Status or RE 1 Date 1 75,000 75 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback 'HVAC=2 C-e-nl�aI-Furnace 866/;AFUE—Split KiiT-Conditioner 1-3.-0 SEER New Setback HVAC -3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -1 Ducted Ducted Attic 4.2 New Yes HVAC -2 Ducted Ducted Attic 4.2 New Yes HVAC -3 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Water Heater System Name Type Distribution A.O. SMITH FPS -75-230 Small Gas Recirc/Time+Tem Multi -Family Central Water Heating Details Hot Water Pump Ratedl Tank Energy Standbyl Tank Insul. # in Input Cap. Condition Factor Loss R -Value Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. 1 75,000 75 New 0.52 n/a n/a Hot Water Piping Length (ft) Add 1/2" n Plenum Outsae urie - Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Gabriel Lujan & Associates Title/Firm: H & H Air Conditioning Address: 45-175 Panorama Drive, #A Address: 74-991 Joni Drive #20 Palm Desert, CA 92260 Palm Desert, CA 92260-2043 } Telephone: (760) 578-8545 Telephone: (7 ) 340-30 Lic. #: 6 (signature) (-date (signature) /(date) i Enforcement Agency Name: Title/Firm: * ddress: Telephone: _ (signature stamp (date) Run Initiation Time: 01/04/06 14:13:57 Run Code: 1136412837 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:6 of 22 r-artifilr_atp Of rmmnlinnlcp - Rpsidp-ntial (AdHAndi lm) CF -1 R /plc tnterprlses I141U0 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the 1 ioequacy OT the special fusurication ano oocumemauon suomiueo. Plan Field Not Valid for permit applications submitted on or after 01/23/06 because Energy Budget is based on SEER 10. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. __ 1 The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R stallation certificate. do uvnc-s.—�ro�., ^FIVAC=1 incnrnnratac NFR'S vorifiad"niirt-Laakane. Ta-leakaae is` calculated and ocd umented or Run Initiation Time: 01/04/06 14:13:57 Run Code: 1136412837 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:7 of 22 1 t The HVAC System "HVAC -1" incorporates a HERS verified—Refrigerant Charge test or a HERS verified Thermostatic Expansion This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Irisulatioi. The HVAC System "HVAC -2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the _ _ Valve T " CFVR. The HVAC System "HVAC -2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansii n Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The HVAC System "HVAC -3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "HVAC -3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all I sulatiori. I I I I Run Initiation Time: 01/04/06 14:13:57 Run Code: 1136412837 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:7 of 22 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance • requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 1 �J L' DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. Building Envelope Measures i§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. § 150(b): Loose fill insulation manufacturers labeled R -Value: *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: ENFORCE-, NIA DESIGNER MENT I ❑ 1!1 ❑ CX -J 11 ❑ o ❑ ❑ ❑ a ❑ ❑X ❑ ❑ ' ❑ ❑X ❑ ❑ 1!1 ❑ M ❑ ❑ o ❑ ❑ ❑ n ❑ ❑X ❑ ❑ ' IJ ❑ ❑ ❑ l=J U ❑ FRI ❑ ❑ M ❑ 0 ❑ ❑ ❑ n ❑ ❑ NEl1:1 U ❑ - L' ❑ J Ex] ❑ ❑ n ❑X ❑ a ❑ a ❑ O ❑ N ❑ Page:8 of 22 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent • compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: continued § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ O ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑X ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause a ❑ ❑ reductions in the cross-sectional area of the ducts. a ❑ x❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ x❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. x❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating o ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑x ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast. §.150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section Y19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. L1ows—! a ❑ ❑ 0 ❑ ❑ ❑X ❑ ❑ a ❑ ❑ ❑ a ❑ x❑ ❑ ❑ X § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more x❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:9 of 22 Residential Kitchen Lighting Worksheet WS -5R plc Enterprises 1/4/06 Project Title -Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide 1 the following information for all luminaires to be installed in kitchens. I High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 14w Linear Fluorescent T5 Elec . Yes X No 18.0 x 5 = 90 or ((1) 26w Compact Fluorescent Triple 4 Pin Yes X No 28.0 x 6 = 168 _ or Elec Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or ' Yes No x = or Yes No x = or Yes No x = or • Total A: 258 B: _ 0 1 COMPLIES IF A > B YES FX NO L] x 1 K-1 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page: 10 of 22 l i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY UJtl:l NAMt UAlt ' Epic Enterprises _ 1/4/06 SYSTEM NAME FLOOR AREA HVAC -1 613 26.0 of Outside 0 cfm 68.9 OF 110.0 / 72.5 of Outside 0 cfm 76.7/62.0 °F 68.9 of 68.9 of Supply Fan 800 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 605 11,806 272 238 9,854 0 1,419 910 0 0 0 0 0 0 0 0 0 910 1,419 14,643 272 Carrier 38TRA02432 18,435 1,249 35,000 Total Adjusted System Output 18,435 7 1,241 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Heating Coil �, Return Air Ducts t4 Supply Air Ducts 109.0 of ROOMS 70.0 of 76.7./ 62.0 of 76.7 / 62.0 of . 55.0 / 53.8 of Supply Air Ducts 56.7 / 54.5 of 46.3% R.H. ROOMS 75.0 / 61.4 OF Supply Fan Cooling Coil 800 cfm Return Air Ducts I EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: -- age:11 of 22^ j HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY OJECT NAME DATE Epic Enterprises 1/4/06 YSTEM NAME FLOOR AREA HVAC -2 1,294 ' ENGINEERING CHECKS ISYSTEM LOAD Sensible Number of Systems CFM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sgft) 54.9 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 37.1 Total Output (sgft/Ton) 323.5 Air System HVAC EQUIPMENT SELE CFM per System 1 600 Airflow (cfm) F400.00.0 00 Airflow (cfm/sgft) .24 •Airflow (cfm/Ton) Outside Air (%) 0.0 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 731 16,503 331 454 19,124 0 0 0 0 1,983 I 1,7651 0� 0 0 1,765 0 0 0 1,983 20,469-1 331 N Carrier 38TRA04834 40,106 39 Total Adjusted System Output� (Adjusted for Peak Design Conditions) 40,106 39 22,654 71,000 1 71,000 Outside Air (cfm/sgft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions HEATING SYSTEUT13MMMETirs ream empera ures 26.0 OF 69.0 OF 69.0 OF 110.7 OF Outside Air 0 cfm Supply Fan Heating Coil 1600 cfm 69.0 OF 110.0 / 72.5 OF • Outside A 0 cfm 76.2 160.5 °F �, Return Air Ducts q 76.2 / 60.5 OF 76.2 / 60.6 OF 52.6 / 51.3 OF 0 Supply Fan Cooling Coil 1600 cfm t �, Return Air Ducts 4 Supply Air Ducts 109.6 OF ROOMS 70.0 OF Supply Air Ducts t i 53.8 / 51.8 of j 41.9% R.H. ROOMS 75.0/60.1°F EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page: 12 of 22 x- VAC SYSTEM HEATING AND COOLING LOADS SUMMARY IFPROJE NAME Epic Enterprises YSTEM NAME t HVAC -3 ENGINEERING CHECKS SY Number of Systems 1 Heating System f ( f I Output per System 55,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Total Output (Btuh) 55,000 Output (Btuh/sgft) 54.5 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 I Total Output (Btuh/sgft) 34.7 Total Output (sgft/Ton) 345.9 0 _ Air System HVAC EQUIPMENT SELE CFM S t 1200 DATE 1/4/06 _ FLOOR AREA 1,009 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 771 18,878 247 450 16,766 29,901 0 — 1 55,000. 2,268 1,548 0 0 0 0 0 0 0 0 0 2,268 1,548 23,415 247 19,862, 1 J.J Outside Air Q 0 cfm Supply Fan Heating Coil 1200 cfm 68.8 OF 1� 1110.0 / 72.5 of Outside Aii 0 cfm _1 79.8162.8 of 6, Return Air Ducts Y 79.8 ! 62.8 of 79.8 / 62.8 of 55.0 / 53.6 of 0 Supply Fan Cooling Coil 1200 cfm Return Air Ducts Pp Y 103.8 of ROOMS 70.0 OF Supply Air Ducts 56.8 / 54.10F 41.1% R.H. ROOMS 78.0 / 62.2 of EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:13 of 22 y _I F., Y. em Carrier 38TRA03633 29,901 440 — 1 55,000. Airflow (cfm) 1,200 I Airflow (cfm/sqft) 1.19 Airflow (cfm/Ton) 411.4 Total Adjusted System Output 28,901 440 55,000 • outside Air o.o (%) (Adjusted for Peak Design Conditions) Outside Air (cfm/sqft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions (Airstream Temperatures at I ime of Heating ea 26.0 OF 68.8 of 68.8 of 105.0 of Su 1 Air Ducts Outside Air Q 0 cfm Supply Fan Heating Coil 1200 cfm 68.8 OF 1� 1110.0 / 72.5 of Outside Aii 0 cfm _1 79.8162.8 of 6, Return Air Ducts Y 79.8 ! 62.8 of 79.8 / 62.8 of 55.0 / 53.6 of 0 Supply Fan Cooling Coil 1200 cfm Return Air Ducts Pp Y 103.8 of ROOMS 70.0 OF Supply Air Ducts 56.8 / 54.10F 41.1% R.H. ROOMS 78.0 / 62.2 of EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:13 of 22 y _I ROOM LOAD SUMMARY ROJECT NAME Epic Enterprises DATE 1/4/06 'YSTEM NAME HVAC -1 FLOOR AREA 613 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite as er suite 1 605 11,806 272 605 11,806 272 238 9,854 PAGE TOTAL TOTAL 605 11,806 272 238 9,854 605 11,806 F 272 238 9,854 EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 22 ROOM LOAD SUMMARY ROJECT NAME Epic Enterprises DATE 1/4/06 YSTEMNAME HVAC -2 FLOOR AREA 1,294 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Great/Kitchen/Dining rea i c en ening 1 731 16,503 331 731 16,503 331 454 19,124 PAGE TOTAL 731 16,503 331 454 19,124 TOTAL 1 731 16,503 331 454 19,124 EnergyPro By EnergySoft User Number: User Job Number: Page: 15 of 22 ROOM LOAD SUMMARY EnergyPro By EnergySoft User Number: User Job Number: Page:16 of 22 ROJECT NAME Epic Enterprises DATE 1/4/06 STEM NAME HVAC -3 FLOOR AREA 1,009 IROOM I= SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ! ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master 2/Bdrm 2/Guest as er rm ues 1 771 18,878 247 771 18,878 247 450 16,766 PAGE TOTAL TOTAL 771 18,878 247 450 16,766 1 771 18,878 247 450 16,766 EnergyPro By EnergySoft User Number: User Job Number: Page:16 of 22 ROOM HEATING PEAK LOADS oject Title DIC Enterprises I Room Information t Room Name } r Floor Area Indoor Dry Bulb Temperature Conduction. uesign conamons Mastersuite Time of Peak 613 Outdoor Dry Bulb Temperature 70 of 1/4/06 AT OF Jan 12 am 26 of Btu/hr i r' i ,• I [ ' ' R-38 Roof(R.30.2x12.16) 613.0 X x x x x x x x x x x x x x X X x X X X X X x x x X x X X X x x X X x X X x x x eight 0.0280 X x x X X x X x X x x x x x X x x x X X X X x X x X X x x X x x X x X X X x x x 44 = = = = = = = = = = = = = = = — = = = = = = — = = = = = = = = = = = = = 755 R-21 Wall (W.19.2x6.16) 64.0 0.0690 44 194 R-21Wall (W.19.2x6.16) 30.0 0.0690 44 91 R-21 Wall (W.19.2x6.16) 106.0 0.0690 44 322 Double Metal Tinted 64.0 0.5300 44 1,492 R-21Wall (W.19.2x6.16) 190.0 0.0690 44 577 Double Metal Tinted 12.5 0.5300 44 291 Double Metal Tinted 12.5 0.5300 44 291 R-21 Wall (W.19.2x6.16) 146.0 0.0690 44 443 Double Metal Tinted 30.0 0.5300 700 Double Metal Tinted 4.0 0.5300 44 93 Slab -On -Grade perimeter = 56.0 0.7300 44 1,799 Slab -On -Grade perimeter = 20.0 0.7300 44 642 - Items shown with an asterisk ('f) denote conduction through an interior Infiltration: I 1.00 x[-1.064 x Schedule Air Sensible Fraction surface to another room. 613 xF 10.00 Areaening LO.452 / 60 AC Page Total: pT 7,692 ' TOTAL HOURLY HEAT LOSS FOR ROOM 10,084 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page: 17 of 22 ROOM HEATING PEAK LOADS �ofect Title Date pic Enterprises 1/4/06 i Room Information Design Conditions Room Name Great/Kitchen/Dining Time of Peak Floor Area 1,294 Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Jan 12 am 26 of Btu/hr • { R-38 Roof(R.30.2x12.16) surface 1,294.0 X X x x x x x x x X x x X X x X x X X X X X X x X X X x X x X x X x X x x x X X eight 0.02801 X X x x X X x x X x X x x x x X x X X X x x X x X X x X X x x X x X x X x X X X 44 = = = = = = = = = = = = = = = = = = = - = = = = = = = = = 1,594 R-21Wall (W.19.2x6.16) 170.0 0.0690 44 516 Solid Wood Door 48.0 1.4500 44 3,062 Double Metal Tinted 25.0 0.5300 44 583 Glass Block 2.0 0.7200 44 63 R-21Wall (W.19.2x6.16) 38.7 0.0690 44 1171 Solid Wood Door 21.3 1.4500 44 _ _ 1211 6891 R-21Wall (W.19.2x6.16) 40.0 0.0690 44 R-21Wall (W.19.2x6.16) 227.0 0.0690 44 Double Metal Tinted 64.0 0.5300 _1,4_92 466 Double Metal Tinted 64.0 0.5300 44 Double Metal Tinted 20.0 0.5300 44 R-21 Wall (W.19.2x6.16) 40.0 0.0690 44 121 R-21Wall (W.19.2x6.16) 60.0 0.0690 44 182 Slab -On -Grade perimeter = 61.0 0.7300 44 1,959 Slab -On -Grade perimeter = 23.0 0.7300 44 739 _ � .. I j `I - Items shown with an asterisk (') denote conduction through an interior Infiltration: [ 1.00 X 1.064 X 1 Schedu a Air Sensible Fraction to another room. 1,294 X 10.00 Area ceiling -1 0.452 / 6] AE J Page Total: pT 14,559 TOTAL HOURLY HEAT LOSS FOR ROOM 24,658 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page. 18 of 22_ r ROOM HEATING PEAK LOADS Tsect Title ic Enterprises Room Information ' Room Name Floor Area Indoor Dry Bulb Temperature Conduction Design Conditions Master2/Bdrm Time of Peak 'i,` W Outdoor Dry Bulb Temperature 70 of Date 1/4/06 AT OF Jan 12 am 26 of Btu/hr R-38 Roof (R.30.2x12.16) 1,009.0 X X X X x x X x x X X x x x X x x x x x x x x x x x x x x x x x x x x x x X eight 0.0280 x x x X x X x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x X 44 = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = = = = = = = -1,243 R-21 Wall (W.19.2x6.16) 125.0 0.0690 441 380 Double Metal Tinted 25.0 0.5300 44 583 R-21 Wall (W.19.2x6.16) 240.0 0.0690 44 729 R-21Wall (W.19.2x6.16) 361.0 0.0690 44 1,096 Double Metal Tinted 25.0 0.5300 44 583 Double Metal Tinted 30.0 0.5300 44 700 Double Metal Tinted 4.0 0.5300 44 93 R-21 Wall (W.19.2x6.16) 205.0 0.0690 44 622 Double Metal Tinted 30.0 0.5300 700 R-21 Wall (W.19.2x6.16) 227.0 0.0690 44 689 Double Metal Tinted 48.0 0.5300 44 1,119 Double Metal Tinted 25.0 0.5300 44 583 I Slab -On -Grade perimeter= 102.0 0.7300 44 3,276 Slab -On -Grade perimeter 29.0 0.7300 44 931 �_ t - ! , Items shown with an asterisk (') denote conduction through an interior Infiltration: [ _ 1.00 X 1.0641 X Schedule Air Sensible Fraction surface to another room. 1,009 X 10.00 Area eil,ng 0.437 / 60] AC Page Total: 0 AT 13,327, 3,439 TOTAL HOURLY HEAT LOSS FOR ROOM 13,327 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page: 19 of 22 T 7 RESIDENTIAL ROOM COOLING LOAD SUMMARY IRoject I me Pic Enterprises Room Information Room Name:. Floor Area: Indoor Dry Bulb Temperature: Opaque Surfaces R-38 Roof(R.30.2x12.16) R-21 Wall (W.19.2x6.16) R-21Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) Date 1/4/06 Design Conditions r Suite Outdoor Dry Bulb Temperature: 613 sf Outdoor Web Bulb Temperature: 75 of Outdoor Daily Range: Orientation Area X x X X x X X x x x x x U -Factor X x X X x X x x x x x x CLTD 1 = = = = = = = = = = = = (North) 613.0 0.0280 56.0 (North) 64.0 0.0690 25.3 (East) 30.0 0.0690 33.0 (South) 106.0 0.0690 26.0 (West) 190.0 0.0690 33.0 (West) 146.0 0.0690 32.0 = 2,097 (West) 0.0 x 32.8 + 12.5 x 67.8 = 847 (West) 0.0 X 32.8 + 12.5 x 67.8 = 847 +- Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • 8 H H G F rayc +Uia+ 75-F 111OF 340F Btu/hr Page Total 5,891 Internal Gain Btu/hr Shaded F __ _4601 Equipment x Dwelling Units x 1,600 Watts/sqft = 1,600 Unshaded 1,769 AiF Sensible CFM E A pl� Orientation 11,606 Area Btu/hr GLF 400 Area 128 GLF Btu/hr (South) 64.0 x 32.8 + 0.0 x 32.9 = 2,097 (West) 0.0 x 32.8 + 12.5 x 67.8 = 847 (West) 0.0 X 32.8 + 12.5 x 67.8 = 847 (West) 0.0 x 32.8 + 30.0 x 61.7 = 1,852 (West) 0.0 x 32.8 + 4.0 x 61.7 = 247 x + x = x + x = x + x X + x = x + x Page Total 5,891 Internal Gain Btu/hr Occupants 2 x Occupants X 230 Btuh/occ. F __ _4601 Equipment x Dwelling Units x 1,600 Watts/sqft = 1,600 Infiltration: l 1.064 x 1.19 x 38.84 x = 36 = 1,769 AiF Sensible CFM E A pl� TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,606 Latent Gain Btu/hr Occupants 2]x Occupants x 200 Btuh/occ. = 11 400 Infiltration: x 1.19 x 38.84 x -0.00058 = 128 __4,771 Air Laten CFM ECA �,W FOR ROOM TOTAL HOURLY LATENT HEAT GAIN 272 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page: 20 of 22 RESIDENTIAL ROOM COOLING LOAD SUMMARY ofectTitle Date piC Enterprises 1/4/06 Room Information Design Conditions Room Name: Great/Kitchen/Dining Outdoor Dry. Bulb Temperature: 75 F Floor Area: 1,294 sf Outdoor Web Bulb Temperature: ill 0F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-38 Roof(R.30.2x12.16) R-21 Wall (W.19.2x6.16) Solid Wood Door R-21Wall (W.19.2x6.16) Solid Wood Door R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) (North) 1,294.0 X x X X x X X X X x x x 0.0280 X x X x x X x X x x x x 56.0 (North) 170.0 0.0690 23.0 (North) 48.0 1.4500 23.0 (North) 38.7 0.0690 25.3 (North) 21.3 1.4500 25.3 (East) 40.0 0.0690 33.0 (South) 227.0 0.0690 26.0 (West) 40.0 0.0690 33.0 (West) 60.0 0.0690 32.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration D C 8 8 J rdyc i Uidi 5,469 Shaded Unshaded Orientation Area GLF Area GLF Btulhr (North) 0.0 x 32.8 + 25.0 X 32.8 = 819 (North) 0.0 x 28.7 + 2.0 X 28.7 = 57 (South) 64.0 x 32.8 + 0.0 x 32.9 = 2,0971 (South) 64.0 x 32.8 + 0.0 X 32.9 = 2,097 (South) 0.0 x 32.8 + 20.0 x 32.9 = 658 x + x = x + x x + x - x + x -- x + x = x + x = Page Total 5,729 Internal Gain Btu/hr Occupants 31 x Occupants X 230 Btuh/occ. = 690 Equipment 0 x Dwelling Units x 1,600 Watts/sgft = 0 Infiltration: 1 1.064 X 1.19 x 81.99 x �36t Air Sensible CFM ply TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,503 Latent Gain Btu/hr Occupants �3 x Occupants x 200 Btuh/occ. _ 0 Infiltration: 4,771 x 1.19 x 81.99 x -0.00058 = L- _2691 Air Latent CFm- ELA & TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 331 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page:21 of 22 1-IRESIDENTIAL ROOM COOLING LOAD SUMMARY epic Enterprises F Room Information Room Name: t Floor Area: Indoor Dry Bulb Temperature: t Opaque Surfaces R-38 Roof(R.30.2x12.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) 11/4/06 Design Conditions Master 21Bdrm 2/Guest Outdoor Dry Bulb Temperature: 787 1,009 sf Outdoor Web Bulb Temperature: 111OF 78 of Outdoor Daily Range: 340F Orientation Area X X X X X X x x x x x x U -Factor X X X X x X x x x x x x CLTD 1 = = = = = = = = = = = = Btu/hr (North) 1,009.0 0.0280 56.0 1,5 (North) 125.0 0.0690 23.0 1' (East) 240.0 0.0690 31.7 S (East) 361.0 0.0690 33.0 8. (South) 205.0 0.0690 26.0 3 (West) 227.0 0.0690 33.0 5 32.8 25.0 67.8 _ Total Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) / Shaded Unshaded Fenestration Orientation Area GLF Area GLF 1 Btulhr 819 1,695 2,034 271 987 2,266 1,695 9,767 Internal Gain (North) Btu/hr 0.0 X x X X x x x X x x X 32.8 + + + + + + + + + + + 25.0 X X x x x x x X x X X Page 32.8 = = = = = = = = (East) 0.0 32.8 25.0 67.8 (East) 0.0 32.8 30.0 67.8 (East) 0.0 32.8 4.0 67.8 (South) 0.0 32.8 30.0 32.9 (West) 28.2 32.8 19.8 67.8 (West) 0.0 32.8 25.0 67.8 Total Btulhr 819 1,695 2,034 271 987 2,266 1,695 9,767 Internal Gain Btu/hr Occupants X 230 Btuh/occ. = 920 BX X Dwelling Units x 1,600 Watts/sgft Infiltration: 1.064 x 1.15 X 63.93 x ' Air Sensib a CFM ECA 33 = p � 2,579 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,878 Latent Gain Btu/hr Occupants 0 X Occupants x C 200 Btuh/occ. = 800 I Infiltration: _ 4,771 x 1.15 x 63.93 x Air Latent CFM ELA -0.00158 = MVV 553 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 247 EnergyPro 4.0 by EnergySoft User Number: 5533 Job Number: Page: 22 of 22 Occupants 4 Equipment 1