0003-052 (SFD) Title 24FROM Christensen/T-24/CABEC
I
FAX NO. : 909 763 0522
Mar. 27 2000 01:20PM P2
Carole Christensen, Certified Energy Analyst
Title -24 Energy Calculations March 27, 2000
ENERGY CALCULATIONS FOR: Lucas Coronel
Coronel Construction
P.O. Box 389 '
La Quinta, CA 92253-0389
PROJECT: The Bireeze
4
Table of Contents ,
CF -IR
MF -IR
C -2R
3R
HVAC
47-S961ekc Canyon Dfi vc, Aguanga, CA 92536
1-800-735-8152
CABFC Certified Encrgy Analyst - Calilornin A ctociation of*Building Energy Consullams
LaQninta, CA 92253
Standard
Proposed
Compliance
North
63.98
61.81
+2.17
East
63.98
63.19
+0.79
South
63.98
59.66
+4.32
East
63.98
62.97
+1-01
CTZ 15
1492 sq.ft.,12.8% fenestration
Dual Aluminum fenestration, Default
Walls R-13+1"Falcon, Roof R-38, Duct R-4.2
AFUE 78%, SEER 10.0
One 40 gal gas water heater, EF.58
Table of Contents ,
CF -IR
MF -IR
C -2R
3R
HVAC
47-S961ekc Canyon Dfi vc, Aguanga, CA 92536
1-800-735-8152
CABFC Certified Encrgy Analyst - Calilornin A ctociation of*Building Energy Consullams
FROM : ChriStenSen/T-24/CABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:20PM P3
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... The Breeze Date..03/27/00 13=07:50
Project Address........ *******
La Quanta, CA *v5.00*
Documentation Author... Carole Christensen ******* Building Permit
Carole Christensen
47-596 Lake Canyon Drive Plan Check Date
Aguanga, CA 92536
800-735-8152 Field check/ Date
Climate Zone........... 15
Compliance Method...... MICROPASS v5.00 for 1999 Standards by Enercomp, Inc.
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
GENERAL INFORMATION
Conditioned Floor Area..... 1.492 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 12.8 % of floor area
Average Glazing U -value.... 0.77 Btu/hr-sf-F
Average Glazing SHGC....... 0.69
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing Total Assembly
Type
Type
R -value
R -value R -value U -value
Location/Comments
Wall
Wood
R-13
R-4.61
R-17.61 0.060
front, corner, back.
right
wall
wood
R-13
R-0
R-13 0.086
to garage
Roof
Wood
R-11
R-27
R-38 0.025
Attic
Door
n/a
R-0
R-n/a
R-0 0.330
solid wood
SlabEdge
n/a
R-0
R-n/a
F2=0.900
to outside
SlabEdge
n/a
R-0
R-n/a
F2=0.720
to outside
SlabEdge
n/a
R-0
R-n/a
F2=0.550
to garage
SlabEdge
n/a
R-0
R-n/a
F2=0.500
to garage
FENESTRATION
Over -
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
Value
SHGC Shading
Shading
Fins
Window
Front (N)
16.0
0.720
0.670 Standard
Standard
None
Window
Front (NE)
5.3
0.630
0.720 Standard
Standard
None
Window
Right (NW)
5.3
0.630
0.720 Standard
Standard
None
Window
Left (E)
24.0
0.720
0.670 Standard
Standard
Yes
Window
Left (E)
12.0
0.720.0.670
Standard
Standard
Yes
Window
Left (E)
4.0
0.720
0.670 Standard
Standard
Yes
Window
Left (E)
4.0
0.720
0.670 Standard
Standard
Yes
Door
Back (S)
40.0
0.850
0.700 Standard
Standard
None
Door
Back (S)
40.0
0.850
0.700 Standard
Standard
None
Window
Back (S)
16.0
0.720
0.670 Standard
Standard
None
Window
Right (w)
4.0
0.720
0.670 Standard
Standard
Yes
Window
Right (W)
4.0
0.720
0.670 Standard
Standard
Yes
FROM : Christensen/T-24/CABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:20PM P4
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
Orientation
Window Right (W)
Equipment Type
Furnace
ACSplit
FENESTRATION
Area U- Interior
(sf) Value SHGC Shading
16.0 0.720 0.670 Standard
SLAB SURFACES
Area
Slab Type (sf)
Standard Slab 1492
HVAC SYSTEMS
Over -
Exterior hang/
Shading Fins
standard Yes
Minimum
Duct
Duct
Tested Duct
ACCA
Thermostat
Efficiency
Location
R -value
Leakage
Manual
D Type
0.800 AFUE
Attic
R-4.2
No
No
Setback
10.00 SEER
Attic
R-4.2
No
No
Setback
WATER HEATING
SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
Storage Gas Standard 1 0.58 40 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
REMARKS
Philips fenestration or better
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Mar. 27 2000 01:21PM P5
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of comVliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name....
Lucas Coronel
Name....
Carole Christensen
Company.
Coronel Construction
Company.
Carole Christensen
Address.
P.O. Box 389
Address.
47-596 Lake Canyon Drive
La Quinta, CA 92253
Aguanga, CA 92536
Phone...
Phone...
800-735-8152
License.
4981
Signed..
signed.
ate
!
ate
ENFORCEMENT AGENCY
Certified Energy Analyst,
Name....
Title...
Carole Christensen, CEPE
Agency..
r r R 98-99-239
r r
Phone...C
A a E C
Signed..
Cotfomlb ,Awcforion of Duilding Energy Consultanrs'
date
FRDM : ChriStensen/T-24i1ZABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:21PM P6
MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page i of 2) WAR
Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all paries
as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the
documents or on this checklist only,
Instructions: Check or initial applicable boxes when -completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Building Envelope Measures:
• § 150(x): Minimum R. 19 ceiling insulation,
1
§ 15o(b): Loose fill insulation manufacturer's labeled R•Valuc.
V Gam/
• § 150(c): Minimum R• 13 wall insulation in wood framed walls or equivalent U•value in metal frame walls
(does riot apply to exterior mass walls).
• § 150(4): Minimum R•13 raised floor insulation in framed floors.
�.
150(') : Slab edge insulation - water absorption rote no greater than 0,3%, water vapor transmission rate no
/
greater than 2.0 arrrVinch,
§ 1 l8: Insulation specified or installed mocts insulation quality standards. Indicate type and form.
§116-17: Fenestration Products, Exterior Doors, and Inftltration/L•x6ltration Controls
I Doors and windows bcnvacn conditioned and unconditioned spaces designed to limit air leakage..
2. fenestration products (except field•fabricated)have label with cenified U•valuc, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
t 3. Exterior doors iitd windows weatherstripped; all joints and penetrations caulked and scaled.
150(g): Vapor barriers mandatory in Climate Zones to and 16 only.
§ 1$00fl; Special infiltration barrier installed to comply with § 151 meets Commission quality standards.
§I50(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
t. Masonry and factory.buili fircptaccs have:
1 a. Closeable metal or glass door
t
b. Outside air intake with damper and control
c. Flue damper and control
I
! 2. No continuous burning gas pilot lights allowed,
Space Conditioning, Water Heating and Plumbing System Measures:
§ 1 10.41 13; HVAC equipment, water heaters, showcrheads and faucets ccrlificd by the Commission.
! §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE. SMACNA or ACCA.
§150(1): Setback thermostat on all applicable heating and/or cooling systems.
I� § 1506): Pipe and tank insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
l
` insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feel of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3 Backup tanks for solar system, unfired storage ranks, or other indirect hot water tanks have R-12 external
s insulation or R. 16 combined internat/external insulation.
i
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55° F insulated.
t
6. Piping ins6lated between heating source and indirect hot water tank.
Y. ... . . -
FROM : Christensen/T-24/CABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:22PM 'P7
MANDATORY MEASURES CHECKLIST: RESIDENTIAL(Page 2 of 2) MF -1R
Note: Lowrisc residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
hems marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all panics
as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the
documents or on this checklist only.
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Space Couditioning, Water Heating and Plumbing System Measures: (continued)
§ 150tm) Ducts and fans
1. All ducts and plenums constructed, installed, insulated, fastened, and scaled to comply with the ICBO 1997
UMC sections 60 t and 603; ducts insulated to a minimum installed R-4,2 or ducts enclosed entirely within
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant or other duct closure system
that rnects the applicable requircmetns of ULI81, ULISIA, or UL ISIS and other applicable specified
tests for longevity given in § 150(m)..
'. Exhaust fan systems have back drag or automatic dampers.
/
1. Gravity ventilating systems serving conditioned space have either automatic or readily accessibic, manually
operated dampers.
114. Pool and Spa Heating Systems and Equipment.
I System is certified with 78% thermal efficiency, on-ofiswitch, weatherproof opera ling
instructions, no electric resistance heating and no pilot light.
2 System is installed with:
a. A( least 16" of pipe between filter and heater for futurt solar heating.
b. Cover for outdoor pools or outdoor spas.
l Pool system has directional inlets and a circulation pump time switch.
§ 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously buming pilot li ht. (Exception: Non -electrical cooking appliances with pilot < 150 BtwAr
Lightin Measures;
150(k)I.: Luminaires for general lighting in kitchens shall have lamps with an efficacy of40 lumens/watt or
greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily
accessible lighting control ncl at an entrance to the kitchen.
§ 150(k)2.: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy
of 40 lumens/wan or greater switched at the entrance to the room or one of the altcmatives to this requirernoni
allowed it, ' t 50 k 2. and recessed ceiling fixtures are IC insulation cover approved.
4
FROM : Christensen/T-24/CRBEC
FAX NO. : 909 763 0522
Mar. 27 2000 01:22PM P8
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... The Breeze Date..03/27/00 13:07:50
Pro'ect Add *******
� ress........
La Quanta, CA *v5.00*
Documentation Author... Carole Christensen ******* Building Permit
-79
Carole Christensen
47-596 Lake Canyon Drive Plan Check Date
Aguanga, CA 92536
800-735-8152 Field Check/ Date
Climate Zone.. ........ 15
Compliance Method...... MICROPAS5 v5.0b for 1999 Standards by Enercomp, Inc.
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM C --2R
User#-MP1017 User -Carole Christensen Run-Drp80.lORl3+PW38.4 40
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
1492 sf
Single Family Detached
New
Cardinal - N,E,S,W
1
1
ReducedYear
Slab On Grade
1
MICROPAS5
ENERGY USE
SUMMARY
Energy
Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space
Heating..........
3.48
2.25
1.23
Space
Cooling..........
44.68
45.35
-0.67
Water
Heating..........
15.82
14.21
1.61
North Total
63.98
61.81
2.17
Space
Heating..........
3.48
2.94
0.54
Space
Cooling..........
44.68
46.04
-1.36
Water
Heating..........
15.82
14.21
1.61
East Total
63.98
63.19
0.79
Space
Heating..........
3.48
3.76
-0.28
Space
Cooling..........
44.68
41.69
2.99
Water
Heating..........
15.82
14.21
1.61
South Total
63.98
59.66
4.32
Space
Heating..........
3.48
3.10
0.38
Space
Cooling..........
44.68
45.66
-0.98
Water
Heating..........
15.82
14.21
1.61
West Total
63.98
62.97
1.01
*** Building complies
with Computer Performance ***
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
1492 sf
Single Family Detached
New
Cardinal - N,E,S,W
1
1
ReducedYear
Slab On Grade
1
FROM : Christensen/T-24/CABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:23PM P9
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.,,....... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-Drp80.l0R13+PW38.4 40
I Zone Type
I HOUSE
Residence
Surface
Conditioned Volume......... 13040 cf
Slab -On -Grade Area......... 1492 sf
Glazing Percentage......... 12.8 � of floor area
Average Glazing U -value.... 0.77 Btu/hr-sf-F
Average Glazing SHGC....... 0.69
Average Ceiling Height..... 8.7 ft
BUILDING ZONE INFORMATION
Floor # of
Area Volume Dwell Cond- Thermostat
(sf) (cf) Units itioned Type
1492 13040 1.00 Yes Setback
OPAQUE SURFACES
Area U- Insul Act Solar
(s£) value R-val Azm Tilt Gains
Vent
Vent
Aix'
Height
Area
Leakage
(ft)
(sf)
CrE°dit
2.0 Standard No
Form 3 Location/
Reference Comments
HOUSE
12
SlabEdge
9
0.900
R-0
No
1
Wall
93
0.060
17.61
0
90
Yes
W13.2X4.16FA
front
2
Wall
45
0.060
17.61
0
90
No
W13.2X4.16FA
R-0
3
Wall
412
0.060
17.61
90
90
Yes
W13.2X4.16FA
0.500
4
Wall
12
0.060
17.61
45
90
Yes
W13.2X4.16FA
corner
5
Wall
12
0.060
17.61
315
90
Yes
W13.2X4.16FA
corner
6
Wall
282
0.060
17.61
180
90
Yes
W13.2X4.16FA
back
7
Wall
276
0.060
17.61
270
90
Yes
W13.2X4.16FA
right
8
Wall
292
0.086
13
0
90
No
GARWALLRI3
to garage
9
Roof
1492
0.025
38
n/a
0
Yes
R,38.2X4.24F
Attic
10
Door
20
0.330
0
0
90
No
None
solid wood
11
Door
17
0.330
0
0
90
No
None
solid wood
Left
(E)
24.0
0.720
PERIMETER
LOSSES
90
Standard/0.76
Standard/0.68
5
Length
F2
Insul
12.0
Solar
0.670
90.
90
Surface
Standard/0.68
(ft)
Factor
R-val
Gains
Location/Comments
HOUSE
12
SlabEdge
9
0.900
R-0
No
to outside
13
SlabEdge
146
0.720
R-0
No
to outside
14
SlabEdge
6
0.550
R-0
No
to garage
15
SlabEdge
31
0.500
R-0
No
to garage
FENESTRATION
SURFACES
Area
U-
Act
Exterior Shade
Interior Shade
Orientation
(sf)
Value
SHGC
Azm
Tilt
Type/SHGC
Type/SHGC
HOUSE
1
Window
Front
(N)
16.0
0.720
0.670
0
90
Standard/0.76
Standard/0.68
2
Window
Front
(NE)
5.3
0.630
0.720
45
90
Standard/0.76
Standard/0.68
3
Window.
Right
(NW)
5.3
0.630
0.720
315
90
Standard/0.76
Standard/0.68
4
Window
Left
(E)
24.0
0.720
0.670
90
90
Standard/0.76
Standard/0.68
5
Window
Left
(E)
12.0
0,720
0.670
90.
90
Standard/0.76
Standard/0.68
FROM : Christensen/T-24/CABEC
FAX NO. : 909 763 0522 Mar. 27 2000 01:23PM P10
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
FENESTRATION SURFACES
System Type
HOUSE
Furnace
ACSplit
SLAB SURFACES
Area
Slab Type (sf)
HOUSE
Standard Slab 1492
HVAC SYSTEMS
Minimum Duct Duct Tested Duct ACCA Duct
Efficiency Location R -value Leakage Manual D Eff
0.800 AFUE Attic R-4.2 No
10.00 SEER Attic R-4.2 No
WATER HEATING SYSTEMS
Number
in
Tank Type Heater Type Distribution Type System
1 Storage Gas Standard I
Energy
Factor
0.58
No 0.743
No 0.596
Tank External
Size Insulation
(gal) R -value
40 R- n/a
Area
U-
Act
Exterior Shade
Interior Shade
Orientation
(sf)
Value
SHGC
Azm
Tilt
Type/SHGC
Type/SHGC
6
Window
Lett
(E)
4.0
0.720
0.670
90
90
Standard/0.76
Standard/0.68
7
Window
Left
(E)
4.0
0.720
0.670
90
90
Standard/0.76
Standard/0.68
8
Door
Back
(S)
40.0
0.850
0.700
180
90
Standard/0.76
Standard/0.68
9
Door
Back
(S)
40.0
0.850
0.700
180
90
Standard/0.76
Standard/0.68
10
Window
Back
(S)
i6.0
0.720
0.670
180
90
Standard/0.76
Standard/0.68
11
Window
Right
(W)
4.0
0.720
0.670
270
90
Standard/0.76
Standard/0.68
12
Window
Right
(W)
4.0
0.720
0.670
270
90
Standard/0.76
Standard/0.68
13
Window
Right
(W)
16.0
0.720
0.670
270
90
Standard/0.76
Standard/0.68
OVERHANGS AND SIDE FINS
Window-
Overhang
Left Fin
Right Fin -
Area
Left
Rght
Surface
(sf)
Wdth
Hgth
Dpth
Hght
Ext
Ext
Ext Dpth Hght
Ext Dpth Hght
HOUSE
4
window
24.0
4.0
4.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
5
Window
12.0
4.0
3.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
6
Window
4.0
4.0
1.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
7
Window
4.0
2.0
2.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
11
Window
4.0
4.0
1.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
12
Window
4.0
2.0
2.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
13
Window
16.0
4.0
4.0
2.0
0.5
n/a
n/a
n/a n/a n/a
n/a n/a n/a
System Type
HOUSE
Furnace
ACSplit
SLAB SURFACES
Area
Slab Type (sf)
HOUSE
Standard Slab 1492
HVAC SYSTEMS
Minimum Duct Duct Tested Duct ACCA Duct
Efficiency Location R -value Leakage Manual D Eff
0.800 AFUE Attic R-4.2 No
10.00 SEER Attic R-4.2 No
WATER HEATING SYSTEMS
Number
in
Tank Type Heater Type Distribution Type System
1 Storage Gas Standard I
Energy
Factor
0.58
No 0.743
No 0.596
Tank External
Size Insulation
(gal) R -value
40 R- n/a
FROM : Christensen/T-24/CABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:23PM P11
COMPUTER
METHOD SUMMARY
Page 4
C -2R
Project
Title.......... The Breeze
Date..03/27/00
13:07:50
MICROPASS v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, **'*
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing,North.
REMARKS
Philips fenestration or better
FROM : Christensen/T-24/CABEC
FAX NO. 909 763 0522 Mar. 27 2800 01:24PM P12
CONSTRUCTION ASSEMBLY Page 1 3R
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPASS v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
Parallel Path Method
Reference Name . W13.2X4.16FA
Descziption .... Wal1R-13 2x4 16oclinFalc
Type ........... Wall
R -Value ........ 17.61 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type wood
Description .. 2x4 fir
Spacing ...... 16 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST
OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
STUCCO.0.88
0.875 in stucco
0.17
0.17
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
R 4.61 RIGID
R-4.61 Insulated Sheathing
4.61
4.61
4c.
SATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
--
4f.
FIR.2X4
2x4 fir
--
3.46
S.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R --Values
19.15
9.61
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing
Total
U -Value: (1 / 19.15
x 0.85) + (1 / 9.61 x 0.15)
= 0.060 Btu/hr-sf-F
Total R -Value: 1 / 0.060 = 16,.66 hr-sf-F/Btu
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Mar. 27 2000 01:24PM P13
CONSTRUCTION ASSEMBLY Page 2 3R
Fxoject Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
Parallel Path Method
Reference Name . GARWALLRI3
Description .... Wall R-11 2x4 16oc
Type ........... Wall
R -Value ........ 1.3 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type ......... Wood
Description .. 2x4 fir
Spacing ...... 1.6 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value R
-Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3c.
BATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
--
3f.
FIR.2X4
2x4 fir
--
3.46
4.
GYP.0.50
0.50 in gypsum or pilaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R --Values
14.81
5.27
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing
Total
U -Value:
(1 / 14.81
x 0.85) + (1 / 5.27 x 0.15)
= 0.086 Btu/hr-sf-F
Total
R -Value:
1 / 0.086 =
11.65 hr-sf-F/Btu
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Mar. 27 2000 01:25PM P14
CONSTRUCTION ASSEMBLY Page 3 3R
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
Parallel Path Method
Reference Name . R.38.2X4.24F
Description .... Roof R-38 2x4 2400
Type ........... Roof
R -Value 38 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type Wood
Description'.. 2x4 fir
Spacing ...... 24 inches on center
Framing Frac.. '0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
BUILTUP.0.38
0.375 in built-up roofing
0.33
0.33
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY.0.50
O.SO in plywood
0.62
0.62
4,
AIR.RF.3.50
3.5 in & greater air space: heat flow up
0.80
0.80
5.
BATT.R27.0
R-27 batt insulation
27.00
27.00
6c.
BATT.RII.0
R-11 batt insul (cavity > 3.5 in)
11.00
--
6f.
FIR.2X4
2x4 fir
--
3.46
7.
GYP.0.63
0.625 in gypsum or plaster board
0.56
0.56
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.61
0.61
Total Unadjusted R -Values
41.15
33.62
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing Total
U -value:
(1 / 41.15
x 0.93) + (1 / 33.62 x 0.07) = 0.025
Btu/hr-sf-F
Total
R -Value:
1 / 0.025 = 40.51
hr-sf-F/Btu
FROM : Christensen/T-24/CABEC FAX N0. : 909 763 0522 Mar. 27 2000 01:25PM P15
HVAC SIZING Page 1 HVAC
Project Title.......... The Breeze Date..03/27/00 13:07:50
Project Address........ *******
La Quinta, CA *v5.00*
Documentation Author... Carole Christensen *******
Carole Christensen
47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
Climate Zone........... 15
Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc.
MICROPAS5 v5.00 File-CORNSIC Wth-CTZ1SS92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
GENERAL INFORMATION
Floor Area .................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude ...................
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design .......
Summer Range ...............
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
1492 sf
13040 Cf
Front Facing
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34'F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
Description (Btuh)
0 deg (N)
Cooling
(Btuh)
Opaque Conduction and Solar......
10415
Building
Permit
Plan
check Date
Field
Check/ Date
Climate Zone........... 15
Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc.
MICROPAS5 v5.00 File-CORNSIC Wth-CTZ1SS92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
GENERAL INFORMATION
Floor Area .................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude ...................
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design .......
Summer Range ...............
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
1492 sf
13040 Cf
Front Facing
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34'F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
Description (Btuh)
0 deg (N)
Cooling
(Btuh)
Opaque Conduction and Solar......
10415
5038
Glazing Conduction ...............
5575
4988
Glazing Solar ....................
n/a
7143
Infiltration .....................
6886
4557
Internal Gain ....................
n/a
2550
Ducts ............................
2288
2428
Sensible Load .................... 25163 26705
Latent Load ...................... n/a 5341
Minimum Total Load 25163 32045
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. it is
the HVAC designers responsibility to consider all factors when selecting
the HVAC equipment.
FROM : Christensen/T-24/CABEC FRX NO. : 909 763 0522 Mar. 27 2000 01:25PM P16
HVAC SIZING Page 2 HVAC
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC. Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
GENERAL INFORMATION
Floor Area .................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude...........'........
Winter Outside Design....'..
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range ...............
Interior Shading Used......
Exterior Shading Used......
overhang Shading Used......
Latent Load Fraction.......
Description
1492 A
13040 cf
Front Facing 90 deg (E)
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34 p
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
(stuh)
Cooling
(Btuh)
Opaque Conduction and Solar......
10415
5038
Glazing Conduction ...............
5575
4988
Glazing Solar ....................
n/a
8658
Infiltration .....................
6886
4557
Internal Gain ....................
n/a
2550
Ducti .... 1 .......................
2288
2579
Sensible Load .................... 251.63 28370
Latent Load ...................... n/a 5674
Minimum Total Load 25163 34044
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability 'of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Mar. 27 2000 01:26PM P17
HVAC SIZING Page 3 HVAC
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPASS v5.00 File-CORNBIC Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
GENERAL INFORMATION
Floor Area .................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude... ..............
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range ...............
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
1492 sf
13040 cf
Front Facing
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
Description (Btuh)
180 deg (S)
Cooling
(Btuh)
Opaque Conduction and Solar......
10415
5038
Glazing Conduction ...............
5575
4988
Glazing Solar ....................
n/a
6136
Infiltration .....................
6886
4557
Internal Gain ....................
n/a
2550
Ducts ............................
2288
2327
Sensible Load .................... 25163 25597
Latent Load ...................... n/a 5119
Minimum Total Load 25163 30716
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
FROM : Christensen/T-24/CRBEC FRX NO. : 909 763 0522 Mar. 27 2000 01:26PM P18
xVAC SIZING Page 4 HVAC
Project Title.......... The Breeze Date..03/27/00 13:07:50
MICROPAS5 v5.00 File-CORNBIC Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40
GENERAL INFORMATION
Floor Area .................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude..........:. .....
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range., .............
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
1492 sf
13040 cf
Front Facing
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
Description (Btuh)
27o deg (W)
Cooling
(Stuh)
Opaque Conduction and Solar...... 10415 5038
Glazing Conduction ............... 5575 4988
Glazing Solar .................... n/a 8386
Infiltration ..................... 6886 4557
Internal Gain .................... n/a 2550
Ducts ............................ 2288 2552
Sensible Load .................... 25163 28071
Latent Load ...................... n/a 5614
Minimum Total Load 25163 33685
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
Ff20M Christensen/T-24/CABEC FRX N0. 909 763 0522
0 6.1.03.`88 14A? F.A1 219F880018 `lark6L1A6SuD➢ort
1:1 PHtPgO¢U�
Mar. 27 2000 01:26PM P19
zoo?
M9" Szli.�? "glut
240 H$ lgorizwal Slider Clexr/AJr/C1car 172
Clear/Argon/Cleu .70
Clear/LowVaear .1.57
Clr/LowE/Arg/Clr' 53
240SH
Single Hung
Clear/Air/Clear .72
ClegLr/Argon/Clear ,70
ClenrlowE/Clear .57
Clr/LowE/Arg/Clr .53
Z40F Picture W[ndow Clear/Adr/Clestr .63
Clear/Argoa/Clw 60
CICArfUwE/Clear .45
Clr/LowE Arg/Clr .41
Philips Produce's uses Spectrally Selective Low.F CuaiiHgs-
7-99
IEEI.�
.67
w/ Grids .61
.67
w/ Grids, .61
,3S
w/ Grids .35
.3n
w/ Grids .35
,6
w/ Grids ,61
,6'/
W/ Grids, .61
.38
w/ Grids ,35
.38
'n/ Grids .3f,
?2
wl Gri.ds .66
72
W/ Grids .66
.40
W/ Grids.37
.40
w/ Grids .3'