BRES2016-0184 Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Filler Residence Addition
81150,Elsworth Pi., Lot 11A. Madison Club
La 'Quinta, CA 92253
Project Designer:
PAR Development
42-240 Green Way;` Suite ;C
Palm Desert, CA 92211
(760) 341-5716
Report Prepared.by:.,
• +•, Tim Scott
Scott Design and Title 24, Inc, ,
74-818 Velie Way, Suite 8
Palm Desert, CA 92260
.(760) 200-47,80 `
- � ,. • 134d�o►b• ol�� •
Date:
8/24/2016'
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
• authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPro.6.7 by EnergySoft User Number: 6712 ID:
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Filler Residence Ca culation Date/Time: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 1 1A -PAR -Garcia -1 6.xml
C* RF -01
Page 1 of 8
GENERAL INFORMATION
01
01
Project Name Filler Residence
02
This building incorporates feature's -that require field testing*and/or.verificatioh by a�certified HERS rater un6hthe supervision ofa CEC-approved HERS provider.
02
Calculation Description Title 24 Analysis
J
.w,,. .-•.y
Energy Use (kTDV/ft2-yr)
03
Project Location 81150 Efsworth Pl., Lot 11A. Madison Club
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 295
12
Project Scope Newly Constructed (Addition Alone)
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 1363
15
Number of Zones 1
16
Slab Area (ft) 1363
17
Number of Stories 1
18
Addition Cond. Floor Area 1363
19
Natural Gas Available Yes
20
Addition Slab Area (ft) 1363
21
Glazing Percentage (%) 36.3%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance•-t�
02
This building incorporates feature's -that require field testing*and/or.verificatioh by a�certified HERS rater un6hthe supervision ofa CEC-approved HERS provider.
03
This building incorporates one'oremore Special Features shown below '-
,moi ,c .w,;, Y 7a. . %
J
.w,,. .-•.y
Energy Use (kTDV/ft2-yr)
If
Proposed Design
Registration Number: 216-N0246008D-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency.Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-24 12:20:26
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.24
4.48
-0.24
-5.7%
Space Cooling
77.78
84.15
-6.37
-8.2%
IAQ Ventilation
0.94
0.94
0.00
0.0%
Water Heating
15.45
7.59
7.86
50.9%
Photovoltaic Offset
--
0.00
0.00
Compliance Energy Total
98.41
97.16
1.25
1.3%
Registration Number: 216-N0246008D-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency.Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-24 12:20:26
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Filler Residence Calculation Date/Time: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis - Input File Name: Filler Addn Madison 11A-PAR-Garcia-16.xm1
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Window overhangs and/or fins
CORF-01
Page 2 of 8 -
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications: '
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation ✓
Cooling System Verifications: s
• Minimum Airflow
• Verified EER
• Verified SEER,
Refrigerant Charge
• fan Efficacy Watts/CFM ' • "
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
—None
- - .. �i 'lk t� it - �. 4z..,..•f is !`+.. �[ r -r -'tet rF-:.:_
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption forenergy use ,compo nents included in the performance -compliance approach for the;Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24; Par66 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
_ Reference Energy Use Energy Design Rating Margin
Percent Improvement
Total Energy (kTDV/f2-yr)* 118.28 117.03 1.25
1.1%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Filler Residence
1363
1
1
1
0
1
Registration Number: 216-N0246008D-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08-24 12:20:26
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Filler Residence Calculation Date/Time: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 11A-PAR-Garcia-16.xm1
CF*RF-01
Page 3 of 8
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Addition Zone
Conditioned
HVAC 11
1363,
10
DHW Sys 1
Window & Door Area (ft2)
OPAQUE SURFACES
01
'
03
04
05
06
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
30d Wall
Addition Zone
R-21 Wall (W.21.2x6.16)
30
- specify -
104
8
90
55d Wall
Addition Zone
R-21 Wall (W.21.2x6.16)
55
- specify -
490
242.5
90
145d Wall
Addition Zone
R-21 Wall (W.21.2x6.16)
145
- specify -
374
185.195
90
210d Wall
Addition Zone
R-21 Wall (W.21.2x6.16)
210
- specify -
121.
0
90
235d Wall
Addition Zone
R-21 Wall (W.21.2x6.16)
235
- specify -
66
30
90
300d Wall
Addition Zone
R-21 Wall (W.21.2x6.16)
300
- specify -
81
0
90
325d Wall
Metal Roof
Addition Zone
Additiori:Zone
" '10h R-21'tWall (W 21.2x6:16) 1.
s, ;F `)I r4Ru38 Mtl. Roof Attic'-` f
T (;325-
r r
specify
f t,
143
954
25
90
R-38 Flat Roof 2
Additiorl2one
. .. R-38 Roof Attic
405
- I-# €-. r N — T-- 1 A %.W V t L- l%
OPAQUE SURFACES – Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
Al
Name
Zone
Type
Orientatio
n
Area (ft2)
Skylight Area
(ft2) ..
Roof Rise
(x in 12)
Roof
Pitch
Roof Tilt
(deg)
Roof
Reflectance
Roof
Emittance
Framing
Factor
R-38 Flat Roof
Addition Zone
R-38 Roof Attic1
- specify -
4.1 •
4
1
0.08
4.76
0.66
0.74
0.1
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Addition Zone Attic RoofAddition Zone Ventilated 1.69993 0.583008 0.802993 Yes Yes
Registration Number: 216-N0246008D-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08-24 12:20:26
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Filler Residence Calculation Date/Time: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 11A-PAR-Garcia-16.xml
CORF-01
Page 4 of 8
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft) Height (ft)
Multipli
er
Area
(ft2)
U -factor
SHGC
Exterior Shading
1
Window
30d Wall (- specify -30)
-
-
1
4.0
0.35
0.20
Insect Screen (default)
12
Window
30d Wall (- specify --30)
--
-
1
4.0
0.35
0.20
Insect Screen (default)
2
Window
55d Wall (- specify --55)
--
--
1
80.0
0.40
0.21
Insect Screen (default)
3
Window
55d Wall (- specify -55)
---
-
1
80.0
0.40
0.21
Insect Screen (default)
4
Window
55d Wall (- specify -55)
7.5
11.0
1
82.5
0.35
0.20
Insect Screen (default)
11
Window
145d Wall (- specify -145)
1.8
8.0
1.333
19.2
0.35
0.20
Insect Screen (default)
5
Window
145d Wall (- specify --145)
10.0
11.0
1
110.0
0.35
0.20
Insect Screen (default)
6
Window
145d Wall (- specify --145)
6.0
8.0
0.5
24.0
0.34
0.19
Insect Screen (default)
62
Window
145d Wall (- specify -145)
3.0
2.0
1
6.0
0.35
0.20
Insect Screen (default)
7
Window
145d Wall (- specify -145)
1.3
10.0
1
13.0
0.35
0.20
Insect Screen (default)
8
Window
145d Wall (- specify --145)
1.3
10.0
1
13.0
0.35
0.20
Insect Screen (default)
9
Window
235d Wall (- specify -235),,- , 3.0 �, -.7;r 10.0 y
1
30.0
0.35
0.20
Insect Screen (default)
10
Window
exi 325d Wall (-specify - 325)G- SE !` 5:0
10.0.0.5
0
^ " 25.0
0.35
0.20
Insect Screen (default)
Skylight
Skylight
R-38 Flat Roof (- specify, -270) , Pw
3
r
1
4.0
0.15
0.10
0
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
4
3
0.1
3
3
0
0
0
0
0
0
0 0
0
11
3
0.1
3
3
0
0
0
0
0
0
0 0
0
5
3
0.1
3
3
0
0
0
0
0
0
0 0
0
6
3
0.1
3
3
0
0
0
0
0
0
0 0
0
62
3
0.1
3
3
0
0
0
0
0
0
0 0
0
7
3
0.1
3
3
0
0
0
0
0
0
0 0
0
8
3
0.1
3
3
0
0
0
0
0
0
0 0
0
9
3
0.1
3
3
0
0
0
0
0
0
0 0
0
10
3
0.1
3
3
0
0
0
0
0
0
0 0
0
Registration Number: 216-NO2460080-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-24 12:20:26
° CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Filler Residence Calculation DatelTime: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 11A-PAR-Garcia-16.xm1
CF*RF-01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofAddition Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity / Frame: R-9.1 / 2x4
R-38 Mtl. Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R -9.1/2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
•. Inside Finish: Gypsum Board
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 Roof Atticl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.041
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
'Exterior
r s t::� QcTl
Cavity / Frame: R-21 / 2x6
Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in
R 21
0.066
Siding/sheathing/decking
" �.. S � �. -,, �.r aa..wi. F.. �..�-.� c...� rav. x. w:...r rc a ., ss "�.� •r
SLAB FLOORS
1 n R f; PR t; '+t0-V1QFR
01 02
03 04 05 06 07 i.
Name Zone
Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction - Heated '-
Slab on Grade Addition Zone
1363 130 None 0.8 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW-Sys 1 - 1/1
DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
Registration Number: 2 i6-N0246008D-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Repdr Generated at: 2016-08-24 12:20:26
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Filler Residence Calculation Date/Time: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 11A-PAR-Garcia-16.xm1
CF*RF-01
Page 6 of 8
WATER HEATERS
---- 01_ _ .._
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0
0.95
199000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION _
01
02
03
04
05
06 "
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
--
Compressor
—.
—
--
—
SPACE CONDITIONING SYSTEMS -
01
02 03 04
05 06
SC Sys Name
System Type Heating Unit Name. Cooling Unit Name
Fan Name Distribution Name
Cooling Component 1:Heating Component 1:Air
Distribution System 1: HVAC Fan -1:1
Other Heating and Cooling i if '"
0-C �Heating Component 1 , Cooling Component 1
'System 1 ? S:' l,•a� ;fi t
HVAC Fan 1 Air Distribution System 1,
R V. %1% 1&- _ - 4l 4 d if S,:A_ . It -_..._ U Yi w- -- —J, st. R 34 r} !T6..,...�..
HVAC - HEATING UNIT TYPES
01 02 03
Name , Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 97.2 AFUE
HVAC -COOLING UNIT TYPES
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAii�Cond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1 -hers -cool
t
Registration Number: 216-NO2460080-000000000-0000 Registration Date/Time: - 2016-08-24 12:25:19
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08-24 12:20:26
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Filler Residence Calculation'Date/Time: 12:19, Wed, Aug 24, 2016
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 11A-PAR-Garcia-16.xml ` _
CORF-01
Page 7 of 8
HVAC COOLING - HERS VERIFICATION
- - 01.
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
-Verified-Refrigerant.
Charge
Cooling Component 1 -hers -cool
Required
150
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03 04
05 06 07
Name
Type
Duct Leakage Insulation R -value
Duct Location Bypass Duct HERS Verification
Air Distribution System 1
DucisAttic
Sealed and tested 8
Attic None Air Distribution System
1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03-
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0 i
�-Not Required, ,
xa,,Not Required
Not Required
Not Required
—
J t W -k" rr #F 1,.-- #r -if, f'f 4L%-. YF F:+ x fir^'=•
HVAC -FAN SYSTEMS.....+sF
01
01 F f: ii '" tp2 f""s t�
f -- Y. N ' 't f r" . X03 04
Name Type """ " '
"` `Fan'Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan
0.58 HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required 0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
28.63
0.25
Default
0
Required
f
Registration Number: 216-N0246008D-000000000-0000 - Registration Date/Time: 2016-08-24 12:25:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-24 12:20:26
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 01OD C*RF-01
Project Name: Filler Residence Calculation Date/Time: 12:19, Wed, Aug 24, 2016 Page 8 of 8
Calculation Description: Title 24 Analysis Input File Name: Filler Addn Madison 11 A -PAR -Garcia -1 6.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2016-08-24 12:25:19
Address:
CEA/HERS Certification Identification (if applicable):
77085 Michigan Drive '
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of .
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted tothe enforcement agency for approval,with,this_building permit application.
Responsible Designer Name: `
;t
Responsible Designer Signature:- C
Tim Scott
Company: ,�
Scott Design Title _ ' "�
Date,Signed-
and 24, Inc.
2016-0824 2:2:19
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-N0246008D-000000000-0000 Registration Date/Time: 2016-08-24 12:25:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-24 12:20:26
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Filler Residence Addition
Building Type
m Single Family m Addition Alone
❑ Multi Family O Existing+ Addition/Alteration
Date
8/24/2016
Project Address
81150 Elsworth Pl., Lot 11A. Madison Club
California Energy Climate Zone
CA Climate Zone 15 1
Total Cond. Floor Area
1,363
Addition
1,363
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Roof Wood Framed Attic
R38
954 Cool Roof
New
Roof Wood Framed Attic
R38
405 Cool Roof
New
Wall Wood Framed
R 21
888
New
Slab Unheated Slab -on -Grade
no insulation
1,363 Perim = 130'
New
FENESTRATION
Orientation Area(ft)
Total Area: 495FGla,,ng Percentage: 36.3 %
U -Fac SHGC Overhang Sidefins
New/Altered Average U Factor: 0.36
Exterior Shades Status
Skylight 4.0
0.150 0.10 none
none
None New
Left (NE) 8.0
0.350 0.20 none
none
Bug Screen New
Left (NE) 160.0
0.400 0.21 none
none
Bug Screen New
Left (NE) 82.5
0.350 0.20 3.0
none
Bug Screen New
Rear (SE) 161.2
0.350 0.20 3.0
none
Bug Screen New
Rear (SE) 24.0
0.340 0.19 3.0
none
Bug Screen New
Right (SW) 30.0
0.350 0.20 3.0
none
Bug Screen New
Front (NKq 25.0
0.350 0.20 3.0
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling
Min. Eff
Thermostat Status
1 Central Furnace
97% AFUE Split Air Conditioner 16.7 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating Cooling
Duct Location
Duct
R -Value Status
HVAC 1 Ducted
Ducted
Attic
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
1 Small Instantaneous Gas
0 0.95
All Pipes Ins
New
EnerqvPro 6.7 by EnerqySoft User Number: 6712 Run Code: 2016-08-24T12:20:47
ID:
Pae 11 of 20
4
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 1 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
'
Coefficient SHGC , and infiltration that meets the requirements of 10-11 1 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
10.8(i):
1 10.8i
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(1) when the
installation of a cool roof is specified on the CFI R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame Floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class 1 or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class 1 or Class Il vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab Floor meets the requirements of § 110.8
1 50.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§I50.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e) I B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Nater Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA using design conditions specified
in §150.0(h)2.
§ I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 1 10.2(c).
§150.00)1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§I50.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2 B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
4
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.0Q)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.0Q)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category 111 or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l :
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 1 10.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§I50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/< inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdrafl or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)1 1:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. "file
§I50.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy _< 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CPM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 1 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
110.4(6)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 1 10.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§ I50.0(k)I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ I50.0(k)I B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of $150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§I50.0(k)IC:
§I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k) I D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kl-lz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)I F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ I50,0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§ I50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ I50.0(k)2Hi
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of §130.5; and all other requirements in '150.0(k)2.
§ I50.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to ' 110.9, and complies with all other applicable requirements in §I50.0(k)2.
§ I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ I50.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
4
r
2013 Low -Rise Residential Mandatory Measures Summary
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with tile applicable requirements in § 1 10.9, § 130.0, $130.2, § 130.4, § 140.7 and 21141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with tile applicable requirements in § 110:9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 1 10.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§I50.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ I50.0(k) I l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
' ' ' ' '
nonresidential garages in 110.9, 130.0, 130. 1, 21130.4, 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ I50.0(k)126:
i. Comply with the applicable requirements in §110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§I 10.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of 211 10.10(b) through 211 10.10(e).
§I 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §1 10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§1 10.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 1 10.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(6) through § 110.10(c)
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 1 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and ermanently'marked as "For Future Solar Electric'.
0
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
iller Residence Addition
Date
8/24/2016
System Name
HVAC 1
Floor Area
1,363
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts .
TOTAL SYSTEM LOAD
COIL
CFM
1,114
227
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 78,000
19,013
1,539 617
20,055
Total Output Btuh 78,000
0
Output Btuh/s ft 57.2
1,098
986
Cooling System
0
0
Output perSystem 58,000
8,579
2,871 227
11,009
Total Output Btuh 58,000
0
4,410
0
Total Output Tons 4.8
1,098
986
Total Output Btuh/s ft 42.6
Total Output s ft/Ton 282.0
1 29,787
1 33,035
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24AN8160-59MN7A80-20
44,911 7,634
78,000
Airflow cfm/s ft 1.47
Airflow cfm/Ton
413.8
Outside Air (%)
11.4%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1 44,911 7,634
Aug 3 PM
78,000
Outside Air cfm/s ft 0.17
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 66 OF
Outside Air -4r
227 cfm Supply Fan
2,000 cfm
72 OF
66 OF 103 OF
FJ
Heating Coil
103 OF
I ROOM
tt�
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78°F 81/66°F 81/66°F 59/58°F
Outside Air
227 cfm Supply Fan Cooling Coil
2,000 cfm
77 / 64 OF
60 / 58 OF
53.3% ` ROOM'
I l:.
76 ! 64 OF
EnergyPro 6.7 by EnergySoR User Number: 6712 Run Code: 2016-08-24T12:20:47
/D: Page 16 of 20
•
F-1
L --A
ROOM HEATING PEAK LOADS
Project Name
Filler Residence Addition
Date
8/24/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Addition
Floor Area 1,363.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
_
_
_
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Mt 1. Roof Attic
954.0
0.0260
46
1,141
R-38 Roof Attic
405.0
0.0260
46
484
Skylight
4.0
0.1500
46
28
R-21 Wall (W.21.2x6.16)
888.3
0.0690
46
2,819
Fixed Window -250T
306.7
0.3500
46
4,938
Patio Door -3300T
160.0
0.4000
46
2,944
Door -3070
24.0
0.3400
46
375
Slab -On -Grade
perim = 130.0
0.7300
46
4,365
c
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,363 X
Area
another room
10.00 X 0.266
Height ACH
Page Total
/60] X
AT
17,095
_ 2,960
TOTAL HOURLY HEAT LOSS FOR ROOM 20,055
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-08-24T12:20:47 /D: Page 18 of 20
1�
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Filler Residence Addition
ROOM INFORMATION DESIGN CONDITIONS
8/24/2016
Room Name
Addition
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,363.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temoerature
76 OF I
Outdoor Dailv Ranae:
34 OF
ODaaue Surfaces
R-38 Mtl. Roof Attic
R-38 Roof Attic
R-21 Wall (W.21.2x.6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
Orientation
(IM
(NE)
(NE)
(SE)
(SW)
(SW)
(NW)
(NW)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
954.0
0.0260
56.0
405.0
0.0260
56.0
96.0
0.0690
27.0
247.5
0.0690
29.9
188.8
0.0690
29.9
121.0
0.0690
29.3
36.0
0.0690
31.4
81.0
0.0690
31.2
118.0
0.0690
29.6
14.4
4.1
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Skylight
1
1
2
3
4
11
5
6
nripntatinn
(M
(NE)
(NE)
(NE)
(NE)
(NE)
(SE)
(SE)
(SE)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
6.8
4.0
20.4
0.0
14.4
4.0
18.7
0.0
14.4
4.0
18.7
0.0
15.8
80.0
23.8
0.0
15.8
80.0
23.8
3.2
14.4
79.3
22.1
15.1
14.4
4.1
18.0
62.8
14.4
47.2
18.0
18.81
1 13.9
1 5.2
Page Total
4.1 Occupants X 245 Btuh/occ.
1,363 Floor Area X 0.50 w/sqft
Infiltration: 1.064 X 0.88 X 62.46 X 36 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
4.1 Occupants X 1 Btuh/occ.
Infiltration: 4,771 X 0.88 X 62.46 X 0.00344
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Run Code: 2 01 6-08-24 71 2:20:47
Btu/hr
1, 389
179
510
389
174
241
3,
tmumr
81
75
75
1,905
1,905
1,795
292
1,756
8,23!
Btu/hr
1,002
2,326
2,115
19,013
Btuthr
634
905
634
0
C
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7812412016
ate
Filler Residence Addition
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Addition
Outdoor Dry Bulb Temperature
, 112 OF
Floor Area
1,363.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OFI
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD�.
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X -
X
=
Page Total
o
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF Btu/hr
6
(SE) 6.0 X 14.4 +
0.0
X
18.0 = 87
7
(SE) 8.2 X 14.4 +
4.8
X
18.0 = 205
8
(SE) 8.2 X 14.4 +
4.8
X
18.0 = 205
9
(SlM • 11.9 X 14.4 +
18.1
X
19.4 = 522
10
(NM 0.0 X 14.4 +
25.0
X
20.9 = 521
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total 1,540
Internal Gain
Btulhr
Occupants
41 Occupants X 245
Btuh/occ.
= 1,002
Equipment
1,363 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.88 X 62.46 X 36 . =
2,115
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
19,013
Latent Gain
Btu/hr
Occupants
41 Occupants X 155
Btuh/OCC.
= 634
Infiltration: 4.771
X 0.88 X Y 62.46 X 0.00344 —
905
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
634
EnenqyPro 6.7 by EneMySoft
User Number.' 6712 RunCode: 2016-08-24712:20:47 /D:
Page 20 of 20