12-1467 (SFD) Title 24
T Vis• . BUILDING ENERGY ANALYSIS REPORT i PROJECT: Mr. & Mrs. Filler 81-150 Elsworth Place La Quinta, CA 92253 Project Designer: , Prest Vuksic Architects 44-530 San Pablo Ave. Palm Desert, Ca 92260 (760) 779-5393 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 CITY OF �� (60��0:0�4780 BUlLDIi�lO & SeFETY DEPT. DECEIVED P ONI D FOR CONST CTION r AUG 2 8.2013 DATE 6&.� CITY OF LA QUINTA Job Number: COMMUNITY DEVELOPMENT Date: a 8/19/2013 ;The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is i authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 1 I EnergyPro 5.1 by EnergySoft_ User Number: 6712 RunCode: 2013-08-19708:38:46 ID: a • BUILDING ENERGY ANALYSIS REPORT PROJECT: A Spec House for Mr. & Mrs. Filler 81-150 Elsworth Place La Quinta, CA 92253 Project Designer: Prest Vuksic Architects 44-530 San Pablo Ave. Palm Desert, Ca 92260 (760) 779-5393 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive C� PaIrn-Desert, Ca 92211 BUj UJ �lrti�C (760f,2@0.4 -i '0 DEpr FOR colvsO VED DATE Tion _ BY Job Number: Date: 8/17/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 0.1 1 • • TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads CI i LY O N TA EryING EPr. FOR CCN JrRU r0 1OI V DA B Y I �Energypro 5.1 by EnergySoft Job Number: ID: User Number: 6712 1 2 3 13 16 20 24 28 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1811712013 Date Project Address 81-150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,224 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,195 Radiant Barrier New Wall Wood Framed R-21 3,614 New Slab Unheated Slab -on -Grade None 5,224 Perim = 447' New Door Opaque Door None 47 New FENESTRATION Orientation Area U- Exterior Factor SHGC Overhang Sidefins Shades Status Skylight 3.2 0.530 0.39 none none None New Front (SE) 76.3 390N 1 70:23—non.,e none Bug Screen New Left (SW 354.1 10. 3j0! r 0,234 noneAA ne--� Bug Screen New Skylight 3.2 0.530 10139 &none�C no ANone New Skylight 3.2 -� , r 0.530 `0:39j�:-none p ,,,-� Uy anon None New Skylight 3.2 0.530rUR CO„9\I no q 1 J none None New Right (NE) 198.0 0.390 0.23 5.0 � v-1101Vnone Bug Screen New Front (SE) 268.1 95 0.23 10.0 none Bug Screen New Front (SE) 35.1 0.390 3 non none Bug Screen New Front (SE) 48.4 0.390 0.23 none a Bug Screen New Left (S) 180.6 0.390 0.23 none none Bug Screen New HVAC SYSTEMS (fit . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 No Pipe Insulation New Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Pa e 3 of 34 • 0 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1811712013 Date Project Address 81 -150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,224 Addition n/a # of Stories - 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Left (SW) 23.3 0.390 0.23 none none Bug Screen New Rear (IM 475.8 0.390 0.23 22.0 none Bug Screen New Rear (NM 18.9 0.390 0.23 1 no a none _ Bug Screen New Skylight 3.2 0.530 0.39 o ey } r C) jnone A� None _ New Skylight 3.2 0.530 0.39 none "'-L" NC7 rione n � �- WJ T New n r r� Skylight 3.2 0.530 0.3 non eAtPP none n _ None % New Skylight 3.2 0.530 0.3 non OR C n - ne V LZDNN ne New Skylight 3.2 0.530 0. 9 none noneTl�lji�fe New Rear (N) 3.0 0.720 0 9 Titin none Bug Scree New Right (NE) 98.1 0.390 0.23nonenone Bug Scre New Left (SVV) 127.2 0.390 0.23 none none Scre n New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Pa e 4 of 34 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 Project Address 81-150 Elsworth Place La Quinta California Energy Climate' Zone CA Climate Zone 15 Total Cond. Floor Area 5,224 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST EI Yes []No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. EI Yes O No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Right (NE) 115.2 0.390 0.23 none none Bug Screen New Left (lM 3.0 0.720 0.39 none gone Bug Screen New Y ins1��-.� • vivST - �� Tp V BY HVAC SYSTEMS (fit . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17T16:32:38 ID: Page 5 of 34 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date A Spec House for Mr. & Mrs. Filler 1 ❑ Multi Family ❑ Existing+ Addition/Alteration $/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 418.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 262.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 120.0 ft2 Covered Slab Floor, 3.500" thick at Living Dining HIGH MASS Design -Verify Thermal Mass: 1,880.0 ft2 Exposed Slab Floor, 3.500" thick at Living Dining The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 960.0 ft2 Covered Slab Floor, 3.500" thick at Master bedroom HIGH MASS Design - Verify Thermal Mass: 536.0 ft2 Exposed Slab Floor, 3.500" thick at Master bedroom The HVAC System HVAC 5 must serve only Living Areas. The noh-closable•area between=zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan attktl�awrre� uireme"nt's inReside int al A endix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 846.0 ft2 Covered SIM Floor,,' ,thick at Hall Theaters lA t�� 51 & , sl► �� � HIGH MASS Design - Verify Thermal Mass: 202.0 ft2 Exposed ab Floor , 50Q;thick at Hall Theater LJ6P7- .�, HERS REQUIRED VERIFICATION `''VS�RUCTioly Items in this section require field testing and/or veif pation by a certified HERS Rater. The i spector must receive a completed CF -4R form for each of the measures d betow ter_final tg42 given. The Cooling System Carrier 58CVX070124ACS424 includes credit for a7'EERdenseP: A c ed HERS rt ter must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 58CVX090124ACB648 includes credit for a 12.7 EER Condenser A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 58CVX090124ACB648 includes credit for a 12.7 EER Condenser A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 6 of 34 IF— L-1 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 8/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 14.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. ILDiN QUINTA .", T HERS REQUIRED VERIFICATIO �xJt °'-ITU P Items in this section require field testing and/or erificatloQPyEi Ee,,'rtif ed -HERS dater. Th inspector must receive a completed CF -4R form for each of the measure listed below for fina'(o be 140 The Cooling System Carrier 58CVX090124ACB648 include cMadiMra 12.7 EER Condenser. A certified HERrater must field verify the installation of the correct Condenser. � The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge a 6- is lor-Disp/a� The HVAC System HVAC 5 includes credit for verified adequate airflow A certified HERS rater must diagnos scally measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. ow a Y 7 t.JG BU1LDfnr�^ A _.TA _. . ��rfZ 1 Y DEPT. -APPP 1-UR COBS TR UCTIow DATE h-nemvPro 5.1 by EnerqySoft User Number., 6712 RunCode: 2013-08-17716:32:38 /D: Page 7 of 34 • • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date A Spec House for Mr. & Mrs. Filler ❑ Multi Family ❑ Existing+ Addition/Alteration 1811712013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.96 5.66 -1.70 Space Cooling 57.84 46.88 10.96 Fans 11.46 16.72 -5.26 Domestic Hot Water 6.98 5.01 1.97 Pumps 0.00 0.00 0.00 Totals 80.24 74.27 5.97 Percent Better Than Standard: 7.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE)120 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 871 428 Fuel Available at Site: Natural Gas (SVO 1,722 688 Raised Floor Area: 0 (NV9 1,610 498 Slab on Grade Area: 5,224 (NE) 1,483 411 Average Ceiling Height: 12.6 Roof 5,224 29 Fenestration Average U -Factor: 0.39 TOTAL: 2,054 Average SHGC: 0.23 Fenestration/CFA Ratio: 39.3 REMARKS The Madison Club STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 8/17/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulatYonlnska�rl tion quality, and building envelope sealing require installer testing field verification by an approvediHER-' rater" �-- and certification and ��llti Dil,„, �''- �,��.J61T- Designer or Owner (per Business & Professions Code)-: g un�r---., _ Company Prest Vuksic Architects . k� y� " s r' iE� t . 'V--) Fd r� Address 44-530 San Pablo Ave. Name Pre st VoksiaArc`hite tsi *fit- i ' I 1 City/State/Zip Palm Desert, Ca 92260 Ph UArE(76) 779-5393 IgAd License # Date - Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-08-17T16:32:38� ID: Page 8 of 34 C] • CERTIFICATE OF COMPLIANCE: Residential Part 4 of R Project Name Spec House for Mr. & Mrs. Filler "5C!F-1 Building Type m Single Family ❑ Addition AloneA ❑ Multi Family ❑ Existing+ Addition/A/2013 OPAQUE SURFACE DETAILS Surface Type Area LlInsulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 677 0.026 R-38 270 20 New 4.2.1-A9 Bedroom 2 Wall 253 0.069 R-21 57 90 New 4.3.1-A6 Bedroom 2 Wall 177 0.069 R-21 115 90 New 4.3.1-A6 Bedroom 2 Wall 216 0.069 R-21 205 90 New 4.3.1-A6 Bedroom 2 Wall 297 0-0691R-21 295 90 1 New 4.3.1-A6 Bedroom 2 Slab 418 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Slab 262 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 1,990 0.026 R-38 270 20 New 4.2.1-A9 Living Dining Wall 96 0.069 R-21 37 90 New 4.3.1-A6 Living Dining Wall 51 0.069 R-21 120 90 New 4.3.1-A6 Living Dining Wall 72 0.069 R-21 151 90 New 4.3.1-A6 Living Dining Wall 71 0.069 R-21 185 90 New 4.3.1-A6 Living Dining Wall 317 0.069 R-21 210 90 New 4.3.1-A6 Living Dining Door 24 0.500 None 210 90 New 4.5.1-A4 Living Dining Wall 224 0.069 R-21 288 90 New 4.3.1-A6Livin Dining Wall 149 O.o69 R-21 300 90 New 14.3.1-A6 ILiving Dining FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Bedroom 2 2 Window 28.6 0.390 NFRC 0.23 NFRC 115 New Dual Metal Tinted Bedroom 2 3 Window 47.7 0.390 NFRC 0.23 NFRC 115 New Dual Metal Tinted Bedroom 2 4 Window 27.5 0.390 NFRC 0.23 NFRC 205 New Dual Metal Tinted Bedroom 2 5 Window 22.6 0.390 NFRC 0.23 NFRC 205 New Dual Metal Tinted Bedroom 2 6 Window 70.0 0.390 NFRC 0.23 NFRC 205 New Dual Metal Tinted Bedroom 2 7 Window 38.0 0.390 NFRC 0.23 NFRC 205 New Dual Metal Tinted Bedroom 2 8 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Living Dining 9 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Living Dining 10 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Living Dining 11 Window 198.0 0.390 NFRC 0.23 NFRC 37 New Dual Metal Tinted Living Dining 12 Window 53.0 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 13 Window 1 55.01 0.390 1 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 14 Window 105.1 0.390 1 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 15 Window 55.01 0.390 1 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 16 Window 18.91 0.390 1 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len I H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 None 1.00 --"� - 9 None 1.00 ] �. ,1 I -` / v� • - �. - 10 None 1.00 ! i� 11 Bug Screen 0.76 10.0 19.8 15.0 -'0. 1 :. 5.0 > 5.0 12 Bug Screen 0.76 10.0 5.3 ,10.0 0:1 • •,10.0 10.0 13 Bug Screen 0.76 10.0 5.5 110.0 ,� 0. l 10.0 - .10.0. 14 Bug Screen 0.76 0.9 18.5 110.0 "041i i C;10'0 , O 10.0 1, - i. 15 Bu Screen 0.76 10.0 5.3 110.0 0.1 10.0 10:'0 1 L I I(1)f ! N 16 JBug Screen 0.761 1 1 rn , - .� BY Er7ergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 -- ilD� 1 Page 9 of 34 C] CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition// Iteration Date 8/17/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit7yExterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Wall 120 0.069 R-21 323 90 New 4.3.1-A6 LivingDining Slab 120 0.730 None 0 180 New 4.4.7-A1 Living Dining Slab 1,880 0.730 None 0 180 New 4.4.7-A1 Living Dining Roof 1,480 0.026 R-38 270 20 New 4.2.1-A9 Master Bedroom Wall 108 0.069 R-21 301 90 1 New 4.3.1-A6 Master Bedroom we// 322 0.069 R-21 338 90 New 4.3.1-A6 Master Bedroom Wall 32 0.069 R-21 12 90 New 4.3.1-A6 Master Bedroom Wall 278 0.069 R-21 43 90 New 4.3.1-A6 Master Bedroom Wall 113 0.069 R-21 233 90 New 4.3.1-A6 Master Bedroom Slab 960 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 536 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,048 0.026 R-38 270 20 New 4.2.1-A9 Hall Theater Wall 305 0.069 R-21 30 90 New 4.3.1-A6 Hall Theater Wall 40 0.069 R-21 115 90 New 4.3.1-A6 Hall Theater Wall 80 0.069 R-21 120 90 New 4.3.1-A6 Hall Theater Door 23 0.500 None 120 90 New 4.5.1-A4 lHall Theater FENESTRATION SURFACE DETAILS ID Type I Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 48.4 0.390 NFRC 0.23 NFRC 151 New Dual Metal Tinted Living Dining 18 Window 30.1 0.390 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 19 Window 30.1 0.390 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 20 Window 30.1 0.390 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 21 Window 30.1 0.390 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 22 Window 30.1 0.390 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 23 Window 30.1 0.390 1 NFRC 0.23 1 NFRC 1851 New Dual Metal Tinted Living Dining 24 Window 23.3 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Living Dining 25 Window 149.0 0.390 NFRC 0.23 NFRC 288 New Dual Metal Tinted Living Dining 26 Window 264.0 0.390 NFRC 0.23 NFRC 288 New Dual Metal Tinted Living Dining 27 Window 62.8 0.390 NFRC 0.23 NFRC 288 New Dual Metal Tinted Living Dining 28 Window 18.9 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Living Dining 29 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom 30 Skylight 3.21 0.530 1 NFRC 0.39 NFRC 1 270 New Double Metal Tinted Skylight Master Bedroom 31 Skylight 3.21 0.530 1 NFRC 0.39 NFRC 1 270 New Double Metal Tinted Skylight Master Bedroom 32 Skylight 3.21 0.530 1 NFRC 0.39 NFRC 1 270 New Double Metal Tinted Skylight Master Bedroom (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat I Wd Ove hang Left Fin Right Fin Len HgL LExt RExt Dist I Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 r 25 Bug Screen 0.76 3.0 48.0 22:0 (r '6:1 '.:22. 0 - 22.0 26 Bug Screen 0.76 10.0 26.0 22.0 .. -0._1 22.0 22.0 f I -T ! 27 Bug Screen 0.76 10.0 6.2 22.0 --'u0 1..,22.0 R. 22.0 f 28 Bug Screen 0.76 J , 29 None 1.00 1 f- -, : 30 None 1.00 31 INone 1.00 �r X111 32 None 1.00 ii N ABY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 IDS- Pae 10 of 34 • 0 L CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1811712013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavitj Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 227 0.069 R-21 250 90 New 4.3.1-A6 Hall Theater Wall 34 0.069 R-21 205 90 New 4.3.1-A6 Hall Theater Wall 32 0.069 0-21 210 90 New 4.3.1-A6 Hall Theater Slab 846 0.730 None 0 180 New 4.4.7-A1 Hall Theater Slab 202 0.730 None 0 180 New 4.4.7-A1 Hall Theater FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom 34 Window 1.0 0.720 NFRC 0.39 NFRC 338 New Glass Block Master Bedroom 35 Window 1.0 0.720 NFRC 0.39 NFRC 338 New Glass Block Master Bedroom 36 Window 1.0 0.720 NFRC 0.39 NFRC 338 New Glass Block Master Bedroom 37 Window 98.1 0.390 NFRC 0.23 NFRC 43 New Dual Metal Tinted Master Bedroom 38 Window 127.2 0.390 NFRC 0.23 NFRC 233 New Dual Metal Tinted Master Bedroom 39 Window 81.0 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Hall Theater 40 Window 34.2 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Hall Theater 41 Window 16.2 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Hall Theater 42 Window 1.0 0.720 NFRC 0.39 NFRC 250 New Glass Block Hall Theater 43 Window 1.0 0.720 NFRC 0.39 NFRC 250 New Glass Block Hall Theater 44 Window 1.0 0.720 NFRC 0.39 NFRC 250 New Glass Block Hall Theater 45 Window 196.0 0.390 NFRC 0.23 NFRC 205 New Dual Metal Tinted Hall Theater (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len Hc1t LExt RExt Dist Len H t Dist Len H t 33 None 1.00 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 1 ki R 1 r 44 Bug Screen 0.76 I ' ` 6. f'° v' -r 45 Bug Screen 0.76 1 A r , DqT� EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013 -08 -17716:33:38 --.-ID: 1 Pae 11 of 34 s • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Bedroom 2 680 7,480 HVAC 2 & 3 Living Dining 2,000 28,000 HVAC 4 Master bedroom 1,496 17,952 HVAC 5 Hall Theater 1,048 12,576 Totals 5,224 0 01 01 1 HVAC SYSTEMS System Name HeatingType Min. Eff. CoolingType Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC 2 & 3 Central Furnace Rrn 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 4 Central Fuace 80% AFUE S lit Air Conditioner 16.0 SEER Setback New HVAC 5 Central Furnace 80% AFUE S lit Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 d New HVAC 5 Ducted Ducted IAttic, Ceiling Ins, vented 1 a0l El lNew WATER HEATING SYSTEMS S stem Name at . TVDe Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M -1-100T6 1 Large Gas No Pipe Insulation 85,000 100 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length dos a�= ,CSF LP, Qu, v� c�S stem Nam.e,���_Lenb Pipe th Pipe Diameter Insul. Thick. Qty. HP Plenum Bll Outside Buned M 0,2 „�.. �--' V C I-) 0 HUCTinwL- 0 DATE ❑ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17T16:32:38-+i'-'fD: Pae 12 of 34 • 0 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name Date A Spec House for Mr. & Mrs. Filler 1811712013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§ 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fiffing tight—fittingdamper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, -meets the -require nts of Standards Table 123 A. � 150(j)3A: Insulation is protected from damage, including that due to sunii ht, moisture a ui ment'maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suctjon lines includes a vapor, retardant' oris ehclosed entirely in conditioned space. i7 '^ s' • J f-' ; 1� ,— 7) 150 4: Solar water -heating systems and/or collectors are certified b the SolarRatin rand G'itifica ion Corporation. DATE y EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode 2013=08-f7T46:32:38-,, __ ID: ji Page 13 of 34 C. MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date A Spec House for Mr. & Mrs. Filler 8/17/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square -feet, and.utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts_ of power per linear foot of illuminated cabinet. FCti CU; 4S1 RUCTIr EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 26W084.7 -T-16-32:38 Ry ID: Page 14 of 34 • • • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date A Spec House for Mr. & Mrs. Filler 1811712013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not. having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l 5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CSF LA QUIP,1TA IN ING u SAFETY DEPT. P�� ROV ED E R CONSTRUCTION �_ BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 15 of 34 Ah • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name A Spec House for Mr. & Mrs. Filler Date 8/17/2013 System Name HVAC 1 Floor Area 680 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 542 9,769 Return Vented Lighting 0 Return Air Ducts 564 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 564 TOTAL SYSTEM LOAD 1 10,897 COIL HTG. Latent CFM 1,069 213 01 0 1,069 1 PEAK Heating System Sensible Output perSystem 51,000 13,239 Total Output Btuh 51,000 Output Btuh/s ft 75.0 651 Cooling System 0 Output perSystem 23,000 0 Total Output Btuh 23,000 0 Total Output ons 1.9 651 Total Output Btuh/s ft 33.8 Total Output s ft/Ton 354.8 14,541 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 58CVX070/24ACB424 15,557 3,092 51,000 Airflow cfm/s ft 1.18 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 15,557 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,092 51,000 AZTR PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 131 OF 131 OF Heating Coil Supply Fan 800 cfm 130 OF ROOM M 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71 / 59 OF 71 /59°F 52/51 °F 52/51 OF MEf G Cooling Coil Supply Fan 800 cfm 52.0% 53 / 52 OF .............__....................... ROOM 70 / 59 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 /D: Page 16 of 34 0 • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name A Spec House for Mr. & Mrs. Filler Date 8/17/2013 System Name HVAC 2 & 3 Floor Area 2,000 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING CFM Sensible Total Room Loads 1,711 34,892 Return Vented Lighting 0 Return Air Ducts 2,014 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,014 TOTAL SYSTEM LOAD 38,920 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 71,000 2,956 895 38,647 Total Output Btuh 142,000 Output Btuh/s ft 71.0 1,899 Cooling System 0 perSystem 47,500 0 0 0 -Output Total Output Btuh 95,000 2,956 0 Total Output ons 7.9 1,899 Total Output Btuh/s ft 47.5 Total Output s ft/Ton 252.6 42,446 "Air S stem CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 58CVX090/24ACB648 69,270 6,247 142,000 Airflow cfm/s ft 1.60 Airflow cfin/Ton 404.2 Outside Air°i° 0.0 % Total Adjusted System Output 69,270 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 6,247 142,000 AZTR PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 113 OF 113 OF 10 f Heating Coil Supply Fan 3,200 cfm 113 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0cfm 71 / 58 OF 71/58°F 50/49°F 50/49°F �r Ir( OF�•-t Q,�i�� � � Supply Fan 51150 OF Cooling Coil 3200cfm1NG.i Q, SAFETY DEPT. x,47.2 % ROOM f.-OF3 CON'S T RUCTION 70 ! 58 OF LAX::: BY EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-08-17T16:32:38 ID: Page 17 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name A Spec House for Mr. & Mrs. Filler Date 8/17/2013 System Name HVAC 4 Floor Area 1,496 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 1,013 20,155 Return Vented Lighting 0 Return Air Ducts 1,164 Return Fan 0 Ventilation 1 0 0 Supply Fan 0 Supply Air Ducts 1,164 TOTAL SYSTEM LOAD 1 22,483 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 71,000 2,112 378 16,379 Total Output Btuh 71,000 Output Btuh/s ft 47.5 805 Cooling System 0 Output per System 47,500 0 0 0 Total Output Btuh 47,500 2,112 0 Total Output ons 4.0 805 Total Output Btuh/s tt 31.8 Total Output s ft/Ton 377.9 1 17,989 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 58CVX090/24ACB648 34,158 3,814 71,000 Airflow cfm/s ft 1.07 Total Adjusted System Output 1 34,158 3,814 1 71,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Airflow cfm/Ton 404.2 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 113 OF G Heating Coil Supply Fan 1,600 cfm 113 OF ROOM 72 OF � I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 10 Outside Air 0 cfm 71 / 58 OF 71 /58°F 51150 OF 51 /50°F AR r©� �T" ' �— L.J'-`I 'hd iy 104 Cooling Coil Supply Fan o 1Loo cfm �. fC �Af ElY SEPT. ......................_51 / 50 F P � VE 0448.5 % ROOM FOR CONSTRUCTION 70 / 58 OF ,T,_ — BY EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 18 o"4 F-9 • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name A Spec House for Mr. & Mrs. Filler Date 8/17/2013 System Name HVAC 5 Floor Area 1,048 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 602 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 12,504 1,339 373 16,187 Total Output Btuh 71,000 0 Output Btuh/s ft 67.7 722 796 Cooling System 0 0 Output perSystem 47,500 0 0 0 0 Total Output Btuh 47,500 0 722 13,947 1,339 0 Total Output ons 4.0 796 Total Output Btuh/s ft 45.3 Total Output s ft/Ton 264.8 17,778 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Alrf low cfm 1,600 Carrier 58CVX090/24AC8648 34,690 2,961 71,000 Airflow cfm/s ft 1.53 Airflow cfm/Ton 404.2 71,000 Jan 1 AM Outside Alr % 0.0% Total Adjusted System Output 34,690 2,961 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 11311F Heating Coil Supply Fan 113 OF 1,600 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 70 / 58 OF 70158 OF 50 / 49 OF 50 / 49 OF tHN I:)! Iikt y I i -; ,_t, r SupplyF 'NG & SAF ETY DEPT. Cooling Coil 50 / 49 OF 1,600 cfm _.° `................................_...........,.. ` f P Pk `0 J E ROOM FOR CONSTRUCTIOiv 7 °° in 70 / 58 OF _ o i I DA,1E — EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 19 of 34 • ROOM LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 8/17/2013 System Name Floor Area HVAC 1 680 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mu CFM Sensible Latent CFM Sensible Latent CFM Sensible raedroom 2 Bedroom 2 1 5421 42 9,7691 1, 069 5421 9,7691 1,0691 2131 13,239 i t7PAGE TOTAL E Y 542 —9,7_69-1-1 1,069 213 13,239 • TOTAr " —542 9, 769` 1, 069 213 13,239 s • • ROOM LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 8/17/2013 System Name Floor Area HVAC 2 & 3 2,000 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name L Room Name Mult. I CFM ESensible I Latent CFMSensible Latent CFM Sensible Living Dining Living Dining 1 1,711 34,892 2,956 1,711 344,8921 2,956 8951 38,647 i AGE TOTAL DA TOTAL * 1,711 34,892 2,956 895 38,647 _ 1-3Y`1_1]_34,892-1-2, 956 895 38,6471 * Total includes ventilation load for zonal systems. Ener Pro 5.1 by EnerqySoft User Number: 6712 Run Code: 2013-08-17T16:32:38 ID: Page 21 of 34 s ROOM LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 8/17/2013 System Name Floor Area HVAC 4 1,496 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name I Room Name I Mult.P1,0131 FM Sensible Latent CFM Sensible Latent CFM Sensible Master Bedroom Master bedroom 1 20,1551 2,112 1,013 20,1551 2,1121 3781 16,379 BUII_CNNG &ISAFEITY D FOR CO to a t�c.t PAGE TOTAL TOTAL' DATE 1 1 1,I 013 20,1155 2,1112 378 16,379 1,013 20,155 2,1112 378 16,379 I ' Total includes ventilation load for zonal EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17T16:32:38 ID: Page 22 of 34 • r: ROOM LOAD SUMMARY Project Name A Spec House for Mr. & Mrs. Filler Date 8/17/2013 System Name HVAC 5 Floor Area ' 1,048 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Hall Theater Hall Theater 1 602 12,504 1,339 602 12,504 1,339 373 16,187 DUI L 01t54%.:� c . )/At- _ I Y Urzi ' I , Total includes ventilation load for zonal systems. RAGE FOR CONSTRUCTION B TOTAL 1 602 12,504 1,339 DAT,IZ-T L 1 kQ02 12,504 1,339 373 16,187 373 16,187 — i EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 23 of 34 • • • ROOM HEATING PEAK LOADS Project Name78/17/2013 ate A Spec House for Mr. & Mrs. Filler ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Time of Peak Jan 1 AM Floor Area 680.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT *F Btu/hr R-38 Roof(R.38.2x14.16) 676.8 X 0.0260 X 46 = 809 Double Metal Tinted Skylight 3.2 X 0.5300 X 46 = 78 R-21 Wall (W.21.2x6.16) 942.6 X 0.0690 X 46 = 2,992 Dual Metal Tinted 234.4 X 0.3900 X 46 = 4,205 Slab -On -Grade perim = 101.0 X 0.7300 X 46 = 3,392 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an int r orsurface to another room Page Total 11,476 CITY C: F Lie Q U I N?A Infiltration:[ 1.00 X 1.064 X 680 -X _L,l� )1) :1k00.%j(� �0289y)F60]• X 46 = 1,763 Schedule Air Sensible Area Height AC AT OV Fraction -Ceiling t.. �'" FOR CONSTRUCTION TOTAL HOURLY HEAT LOSS FOR ROOM 8 1 13,239 DATE BY Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode 201'3=08-17T1'6:32'r3 Page 24 of 34 0 0 ROOM HEATING PEAK LOADS Project Name7811712013 A Spec House for Mr. & Mrs. Filler ate ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Floor Area 2,000.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value R-38 Roof(R.38.2x 14.16) 1,990.4 X 0.0260 Double Metal Tinted Skylight 9.6 X 0.5300 R-21 Wall (W.21.2x6.16) 1,100.0 X 0.0690 Dual Metal Tinted 1,232.0 X 0.3900 Wood Door 24.0 X 0.5000 Slab -On -Grade perim = 140.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X ��� A �. Items shown with an asterisk (') denote conduction through an interior, surface to another room I BUILDING & SAFETY N Il,,_ H "._.. � �Po Infiltration:[ 1.00 X 1.064 X 2,000 X A y 14�.�t b lX� -0.2N2p7h. Schedule Air Sensible Area CeilCng:He 4J )Nb I AGOU Fraction I X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr = 2,381. = 234 = 3,491 = 22,102 = 552 = 4,701 = = = = = = = = = = = = = = = = = = = = = = = = 33,461 46 = 5,186 46 46 46 46 46 46 �K1t�r,��� �aC v Page Total DEPT. M �--- =/-60 ] X I lUl'J AT TOTAL HOURLY HEAT LOSS FOR ROOM DATE -- --- BY 38,647 Energ Pro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-08-17T16:32:38 ID: Page 25 of 34 • 0 • ROOM HEATING PEAK LOADS 'Project Name78/17/2013 A Spec House for Mr. & Mrs. Filler ate ROOM INFORMATION DESIGN CONDITIONS Room Name Master bedroom Floor Area 1,496.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X _X_ L TIO`J AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof(R. 38.2x 14.16) 1,480.0 46 1,770 Double Metal Tinted Skylight 16.0 X X X 0.5300 46 390 R-21 Wall (W.21.2x6.16) 852.7 0.0690 46 2, 706 Glass Block 3.0 0.7200 46 99 Dual Metal Tinted 225.3 X 0.3900 46 4,042 Slab -On -Grade perim = 104.0 X 0.7300 46 3,492 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk ' denote conduction O Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction g I' through an interior surface BiJI(_QING X 1, 96 X Area —X— --- --- � I'�I � 1A Page Total EFT. M DEPT- r"11 j�60 ] X r�T t t" y to another room �i & SAFETY �% T. -J p12!0,,0 X �j OT265 i igCC) S RUG 12,500 TOTAL HOURLY HEAT LOSS FOR ROOM nv _, 16,379 EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-08-17716:32:38 ID.' Page 26 of 34 • • • ROOM HEATING PEAK LOADS Project Name7811712013 A Spec House for Mr. & Mrs. Filler ate ROOM INFORMATION DESIGN CONDITIONS Room Name Hall Theater Floor Area 1,048.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to !�""., FVilimH�hty�jl��LAC�iIION U -Value X x X X x X X X X X X X X X X X x X X X X X X X X X X X X X AT °F Btu/hr = 1,253 = 2,280 = 5,874 = 538 = 99 = 3,425 = = = - = = = = = = = = = = = = = = = = = = = = 13,469 46 R-38 Roof(R. 38.2x 14,16) 1,048.0 0.0260 46 R-21 Wall (W.21.2x6.16) 718.2 0.0690 46 Dual Metal Tinted 327.4 0.3900 46 Wood Door 23.4 0.5000 46 Glass Block 3.0 0.7200 46 Slab -On -Grade perim = 102.0 0.7300 46 _ another roomPage �p���ETY ' `�-1-2AW fix,, �r0i 65P/ DEPT. Total 60 X AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interior suHce BUIUr,-,N x 1048 x Area TOTAL HOURLY HEAT LOSS FOR ROOM �T� BY 16,187 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 27 of 34 • • 17J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name - A Spec House for Mr. & Mrs. Filler 78/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 680.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 14.16) W 676.8 X 0.0260 X 56.0 = 985 R-21 Wall (W.21.2x6.16) (NE) 253.0 X 0.0690 X 30.1 = 525 R-21 Wall (W.21.2x6.16) (SE) 176.7 X 0.0690 X 31.9 = 389 R-21 Wall (W.21.2x6.16) (SW) 215.9 X 0.0690 X 28.8 = 429 R-21 Wall (W.21.2x6.16) (NKq 297.0 X 0.0690 X 31.51 = 645 X X = X X = X X = X X = Page Total 2,973 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr SK9 (tM 0.0 X 25.5 + 3.2 X 78.3 = 251 10 (SE) 0.0 X 16.3 + 28.6 X 22.4 = 641 11 (SE) 0.0 X 16.3 + 47.7 X 22.4 = 1,069 9 (SlA9 0.0 X 16.3 + 27.5 X 19.3 = 531 8 (SK9 0.0 X 16.3 + 22.6 X 19.3 = 436 7 (SW) 0.0 X 16.3 + 70.0 X 19.3 = 1,351 6 (SW) 0.0 X 16.3 + 38.0 X 19.3 = 733 X + X - X + X - Page Total 5,012 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 37.21 X 42 = 1,555 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM (_^ IV-V C) r I A QLIN I A 1 9,769 BUILEPIN aSAFE�'��--DEPT. Latent Gain Btu/hr Occupants 1.0 Occupants X �'� X200 Btuh/occ. = 200 FOR CONS i i- uu 1 lulq Infiltration: 4,771 X 0.94 X 37.21 X 0.00523 = 869 Air Sensible CFM ELA AW 8Y DATE - TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Z�_ 1,069 Ener Pro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2013-08-17716:32:38 ID: Page 28 of 34 • RESIDENTIAL ROOM COOLING LOAD SUMMARY A Spec House for Mr. & Mrs. Filler 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,000.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF I Onaaue Surfaces R-38 Roof(R. 38.2x 14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (W) (NE) (SE) (SE) (S) (SIM (SIM W (NtM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,990.4 0.0260 56.0 96.0 0.0690 27.9 51.0 0.0690 31.7 71.6 0.0690 29.2 71.41 0.0690 26.6 316.7 0.0690 29.3 24.0 0.5000 29.3 224.2 0.0690 31.9 149.1 0.06901 31.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FanPctratinn Sk1 SK2 SK3 28 1 A 2 3 31 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 25.5 3.2 78.3 0.0 25.5 3.2 78.3 0.0 25.5 3.2 78.3 0.0 16.3 198.0 22.4 53.0 16.3 0.0 22.2 55.0 16.3 0.0 22.2 105.1 16.3 0.0 22.2 55.0 16.3 0.0 22.2 0.01 16.3 18.9 22.2 Page Total 2,898 185 111 144 131 641 352 493 321 Btu/hr 251 251 251 4,438 866 898 1,717 898 420 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X O.9a X 1o9.a4 X a2 = C Air Sensible CFM EIA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM-.- --• 34,8921 Latent Gain Occupants _77712.0 Occupants Infiltration: x,771 X 0.9a X I '� Air Sensible CFM ELA (C;' I' tV;�- I_12� UU1iV 1 /-\ �, :,,�. l-c-ry nEPT. 200; =Btuh/occ 44 - J �� r0!00323 -X I U CTI O N AW - Btu/hr 400 Z5561 • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM'j "'"' _ ._.._J 2,9561 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2, 000.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (W.21.2x6.16) (NIM 120.0 X 0.0690 X 29.7 = 246 X X = X X = X X = X X = X X X X = X X = X X Page Total 246 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 29 (SE) 0.0 X 16.3 + 48.4 X 19.8 = 957 22 (S) 0.0 X 16.3 + 30.1 X 17.0 = 511 23 (S) 0.0 X 16.3 + 30.1 X 17.0 = 511 24 (S) 0.0 X 16.3 + 30.1 X 17.0 = 511 25 (S) 0.0 X 16.3 + 30.1 X 17.0 = 511 26 (S) 0.0 X 16.3 + 30.1 X 17.0 = 511 27 (S) 0.0 X 16.3 + 30.1 X 17.0 = 511 30 (SW 0.0 X 16.3 + 23.3 X 19.9 = 463 20 (IM 149.0 X 16.3 + 0.0 X 27.5 = 2,434 Page Total 6,919 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 109.44 X 42 = 4,575 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM t----�---'"� '""-y�`-' a � � � A 1 "Ir- 34,892 gg q{pew, .R. I ( �.I s� �/ • vi U 11'4 1 .s% Latent Gain f w nixll^ ,R,. : =A,EETY DEPT. Btu/hr Occupants 2.0 Occupants X P"3 #`ti E ? f -"?00%'' 8tuh/Occ. = 400 Infiltration: 4,771 X 0.94 X 109.44 X �Uo'.00�23 �!v T RUCTIOt� 2,556 Air Sensible CFM ELA OW nn BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,956! EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Pace 30 of 34 • I� • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate A Spec House for Mr. & Mrs. Filler 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,000.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 19 NO 264.0 X 16.3 + 0.0 X 27.5 = 4,312 18 (lam 62.8 X 16.3 + 0.0 X 27.5 = 1,026 32 (NIM 0.0 X 16.3 + 18.9 X 25.8 = 488 X + X - X + X - X + X - X + X - X + X - X + I X = Page Total 5,826 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 109.44 X 42 = 4,575 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM _ 34,892 Ul I Y Ui- LJA UU91N I /A Latent Gain Pi III i mIrl, A CA' FT1r' DEPT. Btu/hr Occupants 2.0 Occupants X w -i a . r N9PQ 13Whiocc. = 400 Infiltration: 4,771 X 0.94 X 109.4 X rub-oo5-2V TRUCTIOf� 2,556 Air Sensible CFM ELA AW TF --BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2 556 EnerovPro 5.1 bv EneravSoft User Number.- 6712 RunCode: 2013-08-17716:32:38 ID: Page 31 of 34 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 1 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,496.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor 30.5 CLT_ D' R-38 Roof(R. 38.2x 14.16) X X X X X X X X X (tM = = = = = = = = = 1,480.0 X 3.2 0.0260 X 77.0 = R-21 Wall (W.21.2x6.16) 123.2 (NE) 30.5 108.0 X (lM (N) (N) 0.0690 X 33.0 = R-21 Wall (W.21.2x6.16) 33.7 (N) 69.4 322.0 X 1.0 0.0690 X 45.0 = R-21 Wall (W.21.2x6.16) 69.4 (N) 19.2 32.0 X 0.0690 X 31.8 = R-21 Wall (W.21.2x6.16) (NE) 277.9 X 0.0690 X 33.9 = R-21 Wall (W.21.2x6.16) (SW) 112.8 X 0.0690 X 52.5 = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF SK4 SK5 SK6 SK7 SK8 15A 15B 15C 17 Internal Gain (W) (lA� 0.0 X X X X X X X X X 30.5 + + + + + + + + + 3.2 X X X X X X X X X 123.2 = = = = = = = = = 0.0 30.5 3.2 123.2 (W) (K9 0.0 30.5 3.2 123.2 0.0 30.5 3.2 123.2 (lM (N) (N) 0.0 30.5 3.2 123.2 0.0 33.7 1.0 69.4 0.0 33.7 1.0 69.4 (N) (NE) 0.0 33.7 1.0 69.4 0.0 19.2 98.1 27.31 L1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,200 Btu Infiltration: 1.064 X 0.94 X 81.86 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR R Latent Gain Occupants 10 Occupants Infiltration: 4.771 X 0.94 X Air Sensible CFM rTOTAL HOURLY LATENT HEAT GAIN iBUILDUNIG & SAFETY DEPT. x r -:o PR 0� 1200. Dh/occ. I FrnNIsTRUCTION 81.!86 X 0.00523 = 4 AW DATE_ BY Page Total 2,963 246 1.000 4091 Btu/hr 394 394 394 394 394 69 69 69 4,860 Btu/hr 230 0 3,422 20,155 Btu/hr 200 1,912 2.112 • LJ RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 1 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,496.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 16 (SIM 0.0 X 19.2 + 127.2 X 49.6 = 6,306 X + X - X + X - X + X - X + X - X + X = X + X - X + X - X I + I X = Page Total 6,306 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.94 X 81.86 X 42 = 3,422 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM A A A—. A A A k A -C" A! i 20,155 I I If �-) r- LL-f`N U r t V 1 r1% Latent Gain BUILDING & SAFETY DEFT. Btu/hr Occupants 1.0 Occupants X r, C2Oo,,ljfftuhTo-qc. = 200 Infiltration: 4,771 X 0:94 X 81.86x `�.—, ONSTRUCTION 1 0.00523 = 1,912 Air Sensible CFM ELA AW DATE BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ° 2,112 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Page 33 of 34 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Spec House for Mr. & Mrs. Filler 1 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Hall Theater Outdoor Dry Bulb Temperature 112 OF Floor Area 1,048.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 14.16) (W) 1,048.0 X 0.0260 X 56.0 = 1,526 R-21 Wall (W.21.2x6.16) (NE) 304.8 X 0.0690 X 27.0 = 568 R-21 Wall (W.21.2x6.16) (SE) 40.0 X 0.0690 X 31.9 = 88 R-21 Wall (W.21.2x6.16) (SE) 80.4 X 0.0690 X 31.7 = 176 Wood Door (SE) 23.4 X 0.5000 X 31.7 = 371 R-21 Wall (W.21.2x6.16) (W) 227.0 X 0.0690 X 32.1 = 503 R-21 Wall (W.21.2x6.16) (SlM 34.0 X 0.0690 X 28.8 = 68 R-21 Wall (W.21.2x6.16) (SW) 32.0 X 0.0690 X 29.3 = 65 X J X = Page Total 3,363 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 14 (NE) 0.0 X 16.3 + 81.0 X 21.3 = 1,723 13 (NE) 0.0 X 16.3 + 34.2 X 21.3 = 727 12 (SE) 0.0 X 16.3 + 16.2 X 22.2 = 360 5D (W) 0.0 X 28.9 + 1.0 X 50.3 = 50 5E (W) 0.0 X 28.9 + 1.0 X 50.3 = 50 5F (W) 0.0 X 28.9 + 1.0 X 50.3 = 50 4 (SW) 0.0 X 16.3 + 196.0 X 19.3 = 3,783 X + X = X + X = Page Total 6,743 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 57.35 X 42 = 2,397 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM_ _ _ 12,504 CITY OF L CSU I MTA Latent Gain Btu/hr Occupants o Occupants X _�i;v� � �H�=DIY . 200=Btuh/occ.�FPT _ 0 �� Infiltration: 4.771 D X 0.94 X 57.35 D SDLISTR X F�9op�?3-SSTRUCTlOiJ 1,339 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ~ 1,339 Ener Pro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2013-08-17716:32:38 ID: Page 34 of 34