12-1467 (SFD) Title 24 (2)0 BUILDING ENERGY ANALYSIS REPORT PROJECT: A Guest House for Mr. & Mrs. Filler 81-150 Elsworth Place La Quinta, CA 92253 Project Designer: Prest Vuksic Architects 44-530 San Pablo Ave. Palm Desert, Ca 92260 (760) 779-5393 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: 8/17/20'JJ 1-D;OF LA QUINTA NG & SAFETY DEPT. A- PPS COVE The EnergyPro computer program has been used to perform the calculations summarized in this�compliance report!lThis prog authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy I This program developed by EnergySoft, LLC — www.energysoft pom. I DATE --- has approval and is iencv Standards. 0 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 Room Load Summary 14 Room Heating Peak Loads 15 Room Cooling Peak Loads 16 - . 1 EnergyPro 5.1 CITY OF LA QUTABTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA 6712 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 Project Address 81-150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 2,111 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 2,095 Radiant Barrier New Wall Wood Framed R-21 1,886 New Slab Unheated Slab -on -Grade None 2,111 Perim = 230' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Skylight 3.2 0.530 0.39 none none None New Skylight 3.2 0.530 0.39 none none None New Skylight 3.2 0.530 0.39 none none None New Skylight 3.2 0.530 0.39 none none None New Skylight 3.2 0.530 0.39 none none None New Front (NM 101.6 0.390 0.23 none none Bug Screen New Front (NM 16.0 0.390 0.23 4.0 none Bug Screen New Front (NtM 75.5 0.390 0.23 6.0 none Bug Screen New Right (StM 64.0 0.390 0.23 none none Bug Screen New Right (SW) 90.9 0.390 0.23 none none Bug Screen New Right (SlM 198.0 0.390 0.23 6.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 6 & 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Mi'n.[&f]t-D'Distribution�' I I Y' Ui- LJA 'L--'U11*4 1 � DEPT. Status 1 Large Gas 75 0.8� A No',Pipe=Insulation t U � New FOR CONSTRUCTION � I � DATE BY- EnergyPro 5.1 by EnerSoft User Number. 6712 RunCodb;.20,13-0847-T-13:16>18-ID: --�---' Page 3 of 19 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 Project Address 81-150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,111 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes O No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes O No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (SE) 74.0 0.390 0.23 none none Bug Screen New Left (NE) 218.4 0.390 0.23 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status t A r° l IINITA WATER HEATING `'' r �'` ` 6-1V� �` — , v f�+'ILD" +�,FETY DEPT. Status Ot . Type Gallons Min. Eff Distribution,,, t-Ul-( l�Viv� i R is d DATE BY EnergyPro 5.1 by Ener Soft User Number: 6712 Run Code 2019=08=19fi13:1'6:1'8"'"--07- Page 4 of 19 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type ® Single Family 0 Addition Alone o Multi Family O Existing+ Addition/Alteration Date 1811712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White M-1-75T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The Roof R-38 Roof(R.38.2x 14.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility'and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier Split Systems includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 & 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 & 7 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 6 & 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. 17-7—1 N II A N IL-All Di-iiini`JG.&sAFE-f-YDEP-T. I Ar'PPFk0 tl EDr r 1 FOR CONN I tiLJU ►nAT' EBY EnergyPno 5.1 by Ene SoR User Number. 6712 RunCode 20 3_08,J.T-13+16sa8�--�"ID: Pa e 5 of 1 g 0 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date A Guest House for Mr. & Mrs. Filler ❑ Multi Family ❑ Existing+ Addition/Alteration 8/17/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftz- r Space Heating 4.26 6.70 -2.44 Space Cooling 63.31 55.21 8.10 Fans 12.58 19.99 -7.41 Domestic Hot Water 15.89 10.60 5.28 Pumps 0.00 0.00 0.00 Totals 96.04 92.50 3.54 Percent Better Than Standard: 3.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (Nvtq 300 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NtM 480 193 Fuel Available at Site: Natural Gas (NE) 912 218 Raised Floor Area: 0 (SE) 528 74 Slab on Grade Area: 2,111 (SM 804 353 Average Ceiling Height: 14.0 Roof 2,111 16 Fenestration Average U -Factor: 0.39 TOTAL: 854 Average SHGC: 0.23 Fenestration/CFA Ratio: 40.5% REMARKS The Madison Club STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate andcompl e. Documentation Author Company Scott Design and Title 24, Inc, dw 8/17/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation qualit .,and -building en` a pe sealing require installer testing field by HE r�a IN A and certification and verification in ap-p ved . �-; i C.,I i a r, �v DEPT. Designer or Owner (per Business & Professions-C.ode-)iNG Company Prest Vuksic Architectsy AstI "T a Address 44-530 San Pablo Ave. Name Vuksirc itts�` T �� �` ZlO Z ✓ rlA Ut City/State/Zip Palm Desert, Ca 92260 Phone (760) 779-5393 igned _ License # Date I DATE �---- t Ene Pro5.1 b Ene Soft User Number: 6712 RunCode: 20.13-0847T13: 6 18 ID: Pa e 6 of 19 0 0 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity7Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 2,095 0.026 R-38 270 20 New 4.2.1-A9 Guest 1 & 2 Wall 287 0.069 R-21 300 90 New 4.3.1-A6 Guest 1 & 2 Wall 80 0.069 R-21 240 90 New 4.3.1-A6 Guest 1 & 2 Wall 371 0.069 R-21 210 90 New 4.3.1-A6 Guest 1 & 2 Wall 454 0.069 R-21 120 90 New 4.3.1-A6 Guest 1 & 2 Wall 694 0.069 R-21 30 90 New 4.3.1-A6 Guest 1 & 2 Slab 1,649 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 Slab 462 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments- 1 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 2 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 3 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 4 Skylight 3.2 0.530 NFRC 0.39 NERC 270 New Double Metal Tinted Skylight Guest 1 & 2 5 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 6 Window 11.0 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 7 Window 33.6 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 8 Window 3.7 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 9 Window 16.0 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 10 Window 24.5 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 11 Window 35.0 0.390 NFRC 0.23 NFRC 360 New Dual Metal Tinted Guest 1 & 2 12 Window 16.0 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 13 Window 27.4 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 14 Window 25.9 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 15 Window 64.0 0.390 NFRC 0.23 NFRC 240 New Dual Metal Tinted Guest 1 & 2 16 Window 11.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Ri ht Fin Len Hot I LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Buq Screen 0.76 10.0 1.9 4.0 0.1 4.0 4.0 10 Bug Screen 0.76 2.2 11.0 6.0 ---0.1 -6.0 -6.0 11 Bug Screen 0.76 10.0 3.5 6.0 (-0.1 •-' 6.0 6.0 I 12 Bug Screen 0.76 10.0 1.9 6.0 --0.-1 6.0 - 6.0 i 13 Bug Screen 0.76 1 b U i L- I 14 Bug Screen 0.76 15 Bug Screen 0.76 ' 16 Bu Screen 0.76 t ) iv.� E ivv v� Ene Pro 5.1 b Ene Soft User Number: 6712 RunCotle: 013-08-17713:16:18 ID: _ _J Pae 7 of 19 C7 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 29.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 18 Window 25.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 19 Window 42.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 20 Window 111.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 21 Window 45.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 22 Window 25.9 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 23 Window 50.0 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Guest 1 & 2 24 Window 24.0 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Guest 1 & 2 25 Window 11.0 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 26 Window 70.0 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 27 Window 34.3 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 28 Window 35.0 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 29 Window 47.4 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 30 Window 20.7 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hot Wd Overhanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len Hot 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 2.2 19.0 6.0 0.1 6.0 6.0 20 Bug Screen 0.76 10.0 14.0 6.0 0.1 6.0 6.0 21 Bug Screen 0.76 10.0 5.0 6.0 0.1 6.0 6.0 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bu Screen 0.76 _ 27 Bu Screen 0.76 26 Bug Screen 0.76 M i `" 1 t' i P l ( L.; 1: 1 r t -A { 29 Bug Screen 0.76 :PT 1 30 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17713:16:18_ _ BYD:_ -- ( Page 8 of 19 • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 6 & 7 Guest 1 & 2 2,111 29,554 Totals 2,1111 01 01 0 HVAC SYSTEMS System Name Qty. Heatinq Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 6 & 7 2 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 6 & 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 0 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M-1-75T6B 1 Large Gas No Pipe Insulation 85,000 75 0.82 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)c _ o m a a — System Name Pipe Length Pipe Diameter Insul. Thick. Oty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 9 of 19 L_J r_1 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name A Guest House for Mr. & Mrs. Filler Date 8/17/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -IR Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water 'tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table §1500)2: Cooling system piping (suction, chilled water, or brine lines),,and piping,insulated betweibri'>he'atin'g!' i t _._.• source"and indirect hot water tank shall be insulated to Table 150-B and Eq uation 150-A. i C i t U L--' , r -%r- a -r §150(j)2: Pipe insulation for steam hydronic heating systems or hot water, systems'A 5 p'si,:meets=the requir"em'6nt§ of Standards Table 123-A. • - . t •--. �� 1 �" that due sunli htmoisture a ui`mentvmai t Hance afhd wind. 150(j)3A: Insulation is protected from damage, includingto §150(j)3A: Insulation for chilled water piping and refrigerant suction li hes inclUdesm vaporretard'd6f or is enclosed entirely in conditioned space. §150(j)4: Solar water -heating systems and/or collectors are certified Oy the Solar Rating and Gegification_Cor oration. I UA t c ------- — EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 10 of 19 r� L i 0 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date A Guest House for Mr. & Mrs. Filler 811712013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. .§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable contro1.system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square-feet,`And otilitytrooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use•no more than n 20 watts of_poWer per linear foot of illuminated cabinet. FoFl CONS TRUC FICIN -- Y _ - - - EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2013=08 -17713:16:18 ---ID:---- Page 11 of 19 17J • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date A Guest House for Mr. & Mrs. Filler 8/17/2013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - "on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. LA QUINITA SAFETY DEPT. N ROUCI�O�f'I-- F Ii BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2b13.084i7-TJ3-1W_1_8 ID: Page 12 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name A Guest House for Mr. & Mrs. Filler Date 8/17/2013 System Name HVAC 6 & 7 Floor Area 2,111 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,595 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG, PEAK Heating System Sensible Latent CFM Sensible Output perSystem 70,000 32,970 3,4981 762 37,119 Total Output Btuh 140,000 0 Output Btuh/s ft 66.3 1,903 1,824 Cooling System 0 0 Output perSystem 42,000 0 0 0 0 Total Output Btuh 84,000 0 3,498 0 Total Output ons 7.0 1,903 1,824 Total Output Btuh/s ft 39.8 Total Output s ft/Ton 301.6 1 36,777 40,767 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 2,800 Carrier Split Systems 61,693 5,063 140,000 Airflow cfm/s ft 1.33 Airflow cfm/Ton 400.0 Total Adjusted System Output 1 61,693 5,063 1 140,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK r Aug 3P ml F Jan 1 AM Outside Air°/, 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 118 °F 118 °F Heating Coil Supply Fan 1180F 2,800 cfm ROOM 51 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71 / 58 of 71 /58°F 50/49°F 50/49°F t, J! 1 i y t" 1 { SAFETY ptr'T. Cooling Coil Supply, Fan < r' i`� u� S� t `- 51 149 OF 2,800 cfm �"'� / _............. y 3O ` 47 FOR „pt�ISTRUC -i-�,�J ROOM 'Efl 70158 OF fl -----� ) EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 13 of 19 C • A ROOM LOAD SUMMARY Project Name Date A Guest House for Mr. & Mrs. Filler 8/17/2013 System Name Floor Area HVAC6&7 2,111 ROOM LOAD SUMMARY Guest 1 & 2 Guest 1 & 2 Total includes ventilation load for zonal EnergyPro 5.1 by Ener Soft User Ni ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ult. CFM I Sensible Latent CFM I Sensible I Latent CFM I Sensible 1 1 1,5951 32,9701 3, 498 1,5951 32,9701 3,4981 7621 37,119 �{l R I� Y�Jv i . 1,595 32,970 3,498r 762 37,119 1,595 32,970 3,498; 762 37,119 E TOVAC' TOTAL* +D;1TE — --- B 1J 'Y52651 • C] • ROOM HEATING PEAK LOADS Project Name A Guest House for Mr. & Mrs. Filler Date 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Floor Area 2,111-Oft' Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area Z095.0 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr = Z50 = 390 = 5,985 = 15,041 = 7,72 = = = = = = 31,645 46 R-38 Roof(R. 38.2x 14.16) 0.0260 46 Double Metal Tinted Skylight 16.0 X 0.5300 46 R-21 Wall (W.21.2x6.16) 1,885.6 X X X X X 0.0690 46 Dual Metal Tinted 838.4 0.3900 46 Slab -On -Grade perim = 230.0 0.7300 46 X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction X through an interior surface to C X 2,111X t;U)i"���yY� Area Ceiling,Height�• yanother•room QU 8'Y u rF.IY 14.00, Xv «f 0:227 r-,jACH'ii FORCONSTRUCTI i NTPagejTotal DEPT. , /-60-] X � �T TOTAL HOURLY HEAT LOSS FOR ROOM 37,119 DATE ---- B —J EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013=08=f7T13:16:18 ID: Page 15 of 19 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Guest House for Mr. & Mrs. Filler 1 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Outdoor Dry Bulb Temperature 112 °F Floor Area 2,111.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature .70 OF Outdoor Daily Ranqe: 34 OF ODaaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W. 21.2x6.16) R-21 Wall (W. 21.2x6.16) Orientation (SIM (SIM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = Z095.0 0.0260 56.0 286.9 0.0690 31.2 80.0 0.0690 31.7 371.1 0.0690 29.3 454.0 0.0690 31.7 693.6 0.0690 27.0 = = (W) 0.0 3.2 78.3 (IM 0.0 3.2 L= 78.3 = = = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fana_stratinn GSK1 GSK2 GSK3 GSK4 GSK5 G19 G8 G9 G1 Btu/hr 617 175 751 992 1,292 1 6,8771 Orientation Shaded Area X X X X X X X X X GLF 25.5 + 25.5 + 25.5 + 25.5 + 25.5 + 16.3 + 16.3 + 16.3 + 1 16.3 +1 Unshaded Area GLF (IM 0.0 3.2 X 78.3 = (W) 0.0 3.2 X 78.3 = (W) 0.0 3.2 X X 78.3 = = (W) 0.0 3.2 78.3 (IM 0.0 3.2 X X X 78.3 = = = (NIM 0.0 11.0 25.8 (NW) 0.0 33.6 25.8 (MM 0.0 3.7 X 25.8 = (MM 1.5 14.5 X 25.8 = Page Total Btu/hr 251 251 251 251 251 284 867 96 398 Z8,991 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 115.51 X 42 = 4,829 Air Sensible CFM EIA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,970 CITY ()I= LA CSUiN Btu/hr- Latent Gain �. CTY DEPT. Occupants 4•� Occupants X BUiLDINU 6 ` ?00 Btuh/occ. = 800 0:00523''QNSTPUCTIO�v Infiltration: 4,771 X 0.94 X 115.51 X 2,698 Air Sensible CFM ELA ' � I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 nA fE -- ` -® 3.4981 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Guest House for Mr. & Mrs. Filler 1 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 2,111.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranoe: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration G2 GA G3 G22 G20 G23 G11 G10 G7 Shaded Area X X X X X X X X X1 GLF + + + + + + + + +1 Unshaded Area GLF X 25.8 X 25.8 X 25.8 X 25.8 X 25.8 X 22.2 X 19.9 X 19.9 X1 19.9 Page Total = = = = = = = = = 16.7 16.3 7.8 5.2 16.3 29.8 2.4 16.3 13.6 0.0 16.3 27.4 0.0 16.3 25.9 0.0 16.3 64.0 0.0 16.3 11.0 0.0 16.3 29.0 0.0 16.3 25.0 r Btu/hr 474 854 390 707 669 1,422 219 577 497 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 115.51 X 42 = 4,829 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM_ 32,970 s 0 F: LA d��p4 1 Btu/hr Latent GainFC-, Occupants 4.0 Occupants X BUILU1l1'200 Btuh/occ.ED = 800 Infiltration: 4,771 X 0.94 X 115.51 X 0.00523 :v CONSTRUCTION 2,698 Air Sensible CFM ELA 4W I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I DATE - - 3.4981 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name A Guest House for Mr. & Mrs. Filler 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 2,111.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fa_nectratinn G6 G5 G4 G21 G14 G12 G18 G17 GC Gain Orientation Shaded Area GLF X 16.3 X 16.3 X 16.3 X 16.3 X 16.3 X 16.3 X 16.3 X 16.3 X 16.3 Unshaded Area + 0.0 + 0.0 + 0.0 GLF X 19.9 X 19.9 X 19.9 X 19.9 X 22.2 X 22.2 X 21.3 X 21.3 X 21.3 L::: Page Total = = = = = = = = = 42.0 111.0 45.0 0.0 + 25.9 0.0 + + + 50.0 0.0 24.0 0.0 11.0 0.0 + + 70.0 0.0 34.3 4.0 Occupants X 2301 Btuh/occ. _ 1.0 Dwelling Unit X 1,6001 Btu = Infiltration: 1.064 X 0.94 X 115.51 X 42 = Air Sensible CFM ELA AT AL FOR ROOM Latent Gain -Occupants 4.0 Occupants X C Infiltration: 4,771 X 0.94 X 115.51 X Air Sensible CFM ELA TOTAL HOURLY LATENT HEAT GAIN FOR ROOM OF LA QUINTA NG & SAFETY DEPT. :)PROVED DATE by Btu/hr G Btu/hr 686 1,813 735 515 1,111 533 234 1,489 729 7,8451 Btu/hr 920 1,600 4,829 32,970 Btu/hr 800 2,698 w CJ RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date A Guest House for Mr. & Mrs. Filler 1 8/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 2,111.0 R2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X J X I= Page Total 1 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr G16 (NE) 0.0 X 16.3 + 35.0 X 21.3 = 744 G15 (NE) 0.0 X 16.3 + 47.4 X 21.3 = 1,008 G13 (NE) 0.0 X 16.3 + 20.7 X 21.3 = 440 X + X = X + X = X + X - X + X = X + X - X + X = Page Total 2,193 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ.= 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 115.51 X 42 = 4,829 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,970 Latent Gain Btu/hr 1 p 9B A Occupants 4.0 Occupants X �_� � iTy 200 [Btuh/occ.0 1 N 9tr A = 1 800 0" "". DING & SAFETY DEPT. Infiltration: 4,771 X 0.94 X 115.51 X 0.00523 F—�y�"°�,�Q �.�fli"...d V ED 2,698 Air Sensible CFM ELA AW FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,498 EnerPro 5.1 b Ene S R User Number. 6712 RunCode: 2013 -08 -17 -ti f6 1 ID: Pae 19 of 19 Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA. 92543 (951) 766-8777 Fax (951) 766-8778 December 11, 2012 Project No. 544-12197 12-12-327 Prest Vuksic Architects CITY OF LA QUINTABUILDING &SAFETY DEPT. 44-530 San Pablo Avenue, Suite 200 p Palm Desert, California 92260 APP6-'It DIM FOR CONSTFUCTION Subject: Geotechnical Update DATE �aS D E` `�, O O 1 Z Project: Proposed Custom Residente 81150 Ellsworth Place — Lot 11A BY: j The Madison Club La Quinta, California Ref: Geotechnical Investigation Report prepared by Sladden Engineering dated January 28, 2005; Project No: 544-4810, Report No. 05-01-101 Report of Testing and Observation During Rough Grading prepared by Sladden Engineering dated March 2, 2006; Project No. 522-4810; Report No. 06-02-120 As requested, we have reviewed the "above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence to be to be constructed on Lot 11A within the Madison Club development in the City of La Quinta, California. It is our understanding that the proposed residential structure will be of relatively lightweight wood - frame construction and will be supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the initial rough grading of the Madison Club project site and recently regraded. The rough grading included recompaction of the native surface soil along with the placement of engineered fill material to construct the building pad. The site grading is summarized in the referenced Report of Testing and Observation During Rough Grading along with the compaction test results. Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building area that falls within the previously assumed building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction prior to fill placement. The previously removed soil and any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. December 11, 2012 -2- Project No. 544-12197 12-12-327 The referenced reports include recommendations pertaining to the construction of residential structure foundations. The previous reports also address the potential for liquefaction, subsidence and differential settlement. Based upon our review of the referenced reports, it is our opinion that the structural values included in these reports remain applicable for the design and construction of the proposed residential structure foundations. The allowable bearing pressures recommended in the Geotechnical Investigation report remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized, if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.48 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is generally non -expansive and falls within the "very low" expansion category in accordance with the 2010 (CBC) classification criteria. Pertinent 2010 CBC Seismic Design parameters are summarized on the following page. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is SD, generally described as stiff soil. The site is located within UBC Seismic Zone 4. The additional coefficients and factors relevant to seismic mitigation for new construction in accordance with the 2010 California Building Code (CBC) are provided in this report. The seismic design category for a structure may be determined in accordance with Section 1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized on the following page. Sladden Engineering December 11, 2012 -3- Project No. 544-12197 12-12-327 Occupancy Category (Table 1604.5): II Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1):1.500g S1 (Figure 1613.5.1): 0.6009 Fa (Table 1613.5.3(1)): 1.0 Fv (Table 1613.5.3(2)):1.5 Sms (Equation 16-36 (Fa X Ss)): 1.500g Sm1 (Equation 16-37 (Fv X S1)): 1.900g SDS (Equation 16-38 (2/3 X Sms)):1.000g SM (Equation 16-39 (2/3 X Sm1}): 0.600g Seismic Design Category: D We appreciate the opportunity to provide service to you on this project, if you have any questions regarding this letter or the referenced reports please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING BRETT L. Brett L. Anderson EXp. 9/30/v 1144 Principal Engineer CIVIL ENGINEERING SER/gvm F 0 �� Q Copies: 4/ Prest Vuksic Architects Sladden Engineering Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 8/19/2013 'Electronically Sinned at CalCERTS.com by Humberto Bautista (PAR Develonment) 8/19/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name R' DEVELOPMENT Shades Building Type m Single Family ❑ Addition Alone Date A Guest House for Mr. & Mrs. Filler 0.39 none O Multi Family ❑ Existing+ Addition/Alteration 8/17/2013 Project Address Skylight ,,.. 3.2 California Energy Climate Zone Total Cond. Floor Area Addition # of Stories 81-150 Elsworth Place La Quinta •none° CA Climate Zone 15 2,111 n/a 1 FIELD INSPECTION ENERGY CHECKLIST o'n`one' I) Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. none ,._.,ll(None INSULATION Area Special none, Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 2,095 Radiant Barrier New Wall Wood Framed R-21 1,886 New Slab Unheated Slab -on -Grade None 2,111 Perim = 230' /r r.p(ew FENESTRATION Orientation Area U- Factor SHGC OverhangSidefins "'JE R' DEVELOPMENT Shades tatus Skylight 3.2 0.530 0.39 none none None New Skylight ,,.. 3.2 0.53Q 0.39—none., none ,- None _� New Skylight%' 3.2 ,0.530 V0.3' noneV •none° None, New Skylighi�'3.22 j f0.530 0.39 none o'n`one' None. New Skylight _ + 3.2 \ 0.530 0.39 none_ �. none ,._.,ll(None rNew (NM 101.6 r_ r .r x 0.3900.23_nonyes-_f none, Bug, cre NewFront 'eny ' a111!x(! Front (NM 16.0 0.390 0.23 4.0 _ none Bug Screen New Front (NIM. 75.5 0.390 0.23 6.0 none Bug Screen New Right (SW) 64.0 0.390 0.23 none none Bug Screen New Right (SW) 90.9 ; 0.390 0.23 none none Bug Screen New Right (SW) 198.0 0.390 0.23 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 6 & 7 Ducted Ducted �-,, r.—r Attic,,Ceiling lns,,ave ,_ , yy_ � .0 New .. I{ V I 0, Ot-kt-t_ I Y" UE T. WATER HEATING'"'�i'i�.,� Qty. Type Gallons IMin. Eff-i CD-is'tiifj io.n ION Status 1 Large Gas 75 10.82 Pipe Ins lation New I D/XTE 1- BY F—EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 1 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone 0 Multi Family ❑ Existing+ Addition/Alteration 1811712013 Date Project Address 81-150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,111 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ECJ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION '" U- Exterior Orientation Area , Factor SHGC Overhang Sidefins Shades Status Rear (SE) 74.0 0.390 0.23 none none Bug Screen New Left (NE)218.4 0.390,,*-*tz�0.23--..:none,-1 . ,none t=,. Bug Screen, New 7 1 HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status C1TV nT a w WATER HEATING BUILD) `-�� Q1111V�-,q Ot . Type Gallons Min.,Eff a �.,DistrrbutionDEp Status r tl+h by nn �01146 VRUCT10 rq BY Ener Pro 5.1 by Ener Sok User Number: 6712 Run Code: 2013=08 19fi13s�i8 _ ID: Page 2 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type ® Single Family 0 Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date $/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White M-1-75T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Ap endix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier Split Systems includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 & 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 & 7 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 6 & 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic iesting is required to verify that duct leakage meets the specified criteria. 1�LPT. FOR CONSTRUG1JOt t DATE BY EnerqvPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 3 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Develooment) 8/19/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family O Addition Alone Date A Guest House for Mr. & Mrs. Filler O Multi Family 0 Existing+ Addition/Alteration 1811712013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space�Heating 4.26 6.70 -2.44 Space Cooling 63.31 55.21 8.10 Fans 12.58 19.99 -7.41 Domestic Hot Water 15.89 10.60 5.28 Pumps 0.00 0.00 0.00 Totals 96.04 92.50 3.54 Percent Better Than Standard: 3.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NKK 300 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NVI9 480 193 Fuel Available at Site: Natural Gas (NE) 912 218 Raised Floor Area: 0 (SE) 528 74 Slab on Grade Area: 2,111 (SW 804 353 Average Ceiling Height: 14.0 Roof 2,111 16 Fenestration Average U -Factor: 0.39 TOTAL: 854 Average SHGC: 0.23 Fenestration/CFA Ratio: 40.5% REMARKS'' - The Madison Club y. Try STATEMENT OF COMPLIANCE This certificate of compliance' lists the building features and specifications needed to comply with Title 24, Parts,'�1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation'author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 8/17/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance-forms=and worksheets, with the specifications, and with any other calculations submitted with this permit Reco n p thata compliance using duct design, duct sealing, verification of refrigerant charge, insulati�n[nstallation quality, and bulldrng�envelope sealing require vIL-Git,iit- A ' A!r-.�� t� installer testing and certification and field verification , y an approved-HER'S,rat&TY DEPT. Owner Business Professions D Designer or (per & FCod� �6'--10V CONSTRUCTION Company Prest Vuksic Architects Address 44-530 San Pablo Ave. Na rest Vuksic Architects "� DATE City/State/Zip Palm Desert, Ca 92260 Phorae_/760 77�93� BY�gianev License # Date Ener Pro 5.1 bV Ener Soft User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 4 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1811712013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 2,095 0.026 R-38 270 20 New 4.2.1-A9 Guest 1 & 2 Wall 287 6.069 R-21 300 90 New 4.3.1-A6 Guest 1 & 2 Wail 80 0.069 R-21 240 90 New 4.3.1-A6 Guest 1 & 2 Wall 371 0.069 R-21 210 90 New 4.3.1-A6 Guest 1 & 2 Wall 454 6.069 R-21 120 90 New 4.3.1-A6 Guest 1 & 2 Wall 694 0.069 R-21 30 90 New 4.3.1-A6 Guest 1 & 2 Slab 1,649 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 Slab 462 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 2 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 3 Sk yli2ht 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted S li ht Guest 1 & 2 4 Skylight 3.2 0.536 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 5 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Guest 1 & 2 6 Window 11.0 0.390 NFRC -' 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 7 Window '33.6 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 8 Window 3.7 6.390 NFRC 6.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 9 Window 16.0 0.396 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 10 Window 24.5 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 11 Wridow 35.0 0.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 12 Window 16.0 6.390 NFRC 0.23 NFRC 300 New Dual Metal Tinted Guest 1 & 2 13 Window 27.41 0.390 NFRC 0.23 NFRC 300UNew Dual Metal Tinted Guest 1 & 2 14 Window 25.9 0.390 NFRC 0.23 NFRC 300Dual Metal Tinted Guest 1 8 2 15 Window 64.0 0.390 NFRC 0.23 NFRC 240Dual Metal Tinted Guest 1 & 2 16 Window 11.0 0.390 NFRC 0.23 NFRC 210Dual Metal Tinted Guest 1 & 2 (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 Bug Screen 0.76 i t 1! 7 Bug Screen 0.76 -41 ..I . • i _ - ` ' 8 Bug Screen 0.76 - ` ' ` �- 1 r 9 Bug Screen 0.76 10.0 1.9 P.0 011 1-- 4.0 14.0 rl 10 Bug Screen 0.76 2.2 11.0 16.0 E04% 6,0; ; , f a 6.0- 11 Bug Screen 0.76 10.0 3.5 6.0 0-f '& 1 �' `' 6.10'1 V t I 12 Bug Screen 6.76 10.0 1.9 6.0 0.1 6.0 6.0 13 Bu Screen 0.76 14 Bu Screen 0.76 15 Bu Screen 0.76 16 JBug Screen 1 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2013-08-17713:16:18 ID: Pa e 5 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1811712013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 29.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 18 _ Window 25.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted Guest 1 & 2 19 Window 42.0 0.390 NFRC 0.23 NFRC 210 New Dual Metal Tinted --al Guest 1 & 2 20 Window 111.0 0.390 NFRC 0.23 NFRC 210 New Tu Meta! Tinted Guest 1 & 2 21 . Window.45.0 0.390 NFRC _ _-013 NFRC___ ._ 210 New._,.,,,_,..,,. Dual Metal_Tinted- . , _. Guest 1 & 2 22 Window- 25.9 0.390 NFRC .A 0.23 ;NFRC 210 New k� DuafMetal Tinted V /i+ j Guest 1 & 2 23 Window '50.0 0..390 NFRC J 0.23 NFRC 120 New Dual Metal Tinted i .: " Guest 1 & 2 24 Window 24.0 70.390 NFRC 0.23 NFRC 120 New. r Dual Metal Tinted k Guest 1 & 2 25 Window 1.4YO i 0.390 NFRC 0.23 NFRC V 30 New Dual Metal Tinted ?, L. Guest,l,& 2. 26 Window j �76.o- ] 0.390 NFRC 6.23 NFRC, 430 New; -.3 Dual Metal Tinted 1( 1 GuestA& 2'f 27 Windowod 7 L34.3 -0.390 NFRC --,,0.23 NFRC : t=,r 30 New Dual Metal Tinted GuestJ & 2' k'I O 28 Window 35.0 0.390 NFRC 0.23 NFRC -30 New Dual Metal Tinted Guest 1 & 2 29 Window _- 47.4 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 30- Window 20.7 0.390 NFRC 0.23 NFRC 30 New Dual Metal Tinted Guest 1 & 2 (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hat Wd Overhanq Left Fin Len Hat LExt RExt Dist Len Ri ht Fin H t Dist Len Hat 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 2.2 19.0 6.0 0.1 6.0 6.0 20 Bug Screen 0.76 10.0 14.0 6.0 0.1 6.0 6.0 21 Bug Screen 0.76 10.0 5.0 r-64,0:.-0-1. B.0 6.0 22 Bug Screen 0.76 r"t 9' rN,4r r'N r sw A A A A -A- 23 Bug Screen 0.76 Oil J I 24 Bug Screen 0.76 LLltt.-LA ;IC -i & :;AF-?- F 7 25 Bug Screen 0.76 A.- 26 Bug Screen 0.76 27 Bug Screen 0.76 FOR : > T I 28 Bug Screen 0.76 29 Bug Screen 0.76 30 30RY Bu Screen 0.76 DATr- Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2013-08-17713:16:18 ID: Page 6 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name A Guest House for Mr. & Mrs. Filler Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date $/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered I Removed Volume Year Built HVAC 6 & 7 Guest 1 & 2 2,111 29,554 Totals 2,111 0 ol 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. C601inq Type Min. Eff. Thermostat Type Status HVAC 6 & 7 2 , Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New -77- T zeh HVAC DISTRIBUTION d e` ! i1 _.. / :: s,b 1 A I ;i i I,/ -its System Name ` + Heating -m4Duc,04. 'V Ducts7L Cooling� Duct Location R -Value Tested? Status HVAC 6 & 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New ❑ WATER HEATING SYSTEMS S stem Name Qt . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M-1-75T6B 1 Large Gas No Pipe Insulation 85,000 75 0.82 0.00 "/o n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Pi ing�er�gt r' z I.� U I NT� E i is1". SAFETY DEPT.-.91q0;� Plenum Ou side rigid — S stem' Name Pipe Len th Pipe Diameter Insul. Thick. Qt . HP � 1 HUCTInr o a Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17713:16:18 ID: Page 7 of 7 Reg: 213-N0063814A-000000000-0000 Registration Date/Time: 2013/08/19 14:00:21 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS-com by Humberto Bautista (PAR Development) 8/19/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 Project Address 81-150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,224 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special CavitX (ftp Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,195 Radiant Barrier New Wall Wood Framed R-21 3,614 D New Slab Unheated Slab -on -Grade None 5,224 Perim - 4 New Door Opaque Door None 47 New AU6 2S.2013"' CITY OMMUN .. . FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 3.2 0.530 0.39 none none None New Front (SE) . r �- 76.3 0.390.x..0.23—none-, ,---,-nope ,f►-•---Bug,SpreenpwAtz:.„ New Left (SiMl /r f 354.1 0.590 Ilr 0. 23none' none Bug Screen I V New Skylight A<2 � , � 0.530 0.39 none � none � None X '. �g New t Skylight 3.2 ;r 0.530 0.'!39 none, ! none - -None] `' �` f ,New ' ne; _ None,`-0.530.09`noe lnoSkyligh.�''New Right (NE) 198.0 0.390 0.23 5.0 none _ Bug Screen New Front (SE) 268.1 0.390 0.23 10.0 none Bug Screen New Front (SE) 35.1 0.390 0.23 none none Bug Screen New Front (SE) 48.4 0.390 0.23 none none Bug Screen New Left (S) 180.6 0.390 0.23 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted'—" ----Attic, Ceiling_Ins, vented 8.0 New HVAC 4 Ducted Ducted C, I l-Attic,rCeo,h-g lns,Tver�ted r 8.0 New WATER HEATING E LIELD,',VC &c. /A Ot . Type Gallons Min. Eff .- rDistrib ion DEPT. Status 1 Large Gas 1000.80 ' No Pi a Msulat of New t �( t)� r��v na TG •— - BY Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17716:32:38 Pagel of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 Project Address 81-150 Elsworth Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,224 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area ',Factor Exterior SHGC Overhang Sidefins Shades Status Left (SIM 23.3 0.390 0.23 none none Bug Screen New Rear (W) 475.8 0.3$Q 0.23- 22;0 .none _ Bug;Screen� New Rear (N yo 18.9 0.390 0 23 none j none - :Bug Screeh New Skylight l 3.2., 0:530 0:,39, . ,-no a M; none :; None New - Skylight 1'17, ,f 3.2 P.: t 0.530 0]39 none tr rr f. S li ht 3.2 0.5300 39 nonehone, None New kl' 9 � � a� : - 1 'j 1 ` . Skylight 3.2 ) 0.530 0.39 none none None New Skylight. _ 3.2 0.530 0.39 none none None New Rear (N) 3.0 0.720 0.39 none none Bug Screen New Right (NE) 98.1 0.390 0.23 none none Bug Screen New Left (SIM 127.2 0.390 0.23 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING fid OF LA QUINT Ot Type Gallons Min.It"HI .ODistribution.� _ A Status 1 Afft-+t -✓ �� C�N F�'1,LA a,r`— V "Liu I IUN j !BATF Ener Pro 5.1 by Ener Soft User Number: 6712 RunC6de:_2013-08-17716:32:38 —0 Page 2 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 RERS--Ar..Jder: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 8/19/2013 Electronically Signed at Ca10ERTS.com by Humberto Bautista (PAR Development) 8/19/2013 :, L PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name A Spec Mouse for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1811712013 Date Project Address 81-150 Elsworth Place La Quinta California Energy Cliimate Zone CA Climate Zone 15 Total Cond.' Floor Area 5,224 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (NE) 115.2 0.390 0.23 none none Bug Screen New Leff (W ,r, ;; �„ r 3.0 �, 0.72Q 0.39— none i „per none ; 6ug-Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Li'l- g e i.t9 K 1 LA QUIfNT 1 WATER HEATING `�U"' 0 -- SAF DEPT. Ot . Type Gallons Min. Eff` D stri;b Ajoncr-, Status FOR CONST I TI DATE Rv Ener Pro 5.1 by Ener Soft User Number: 6712 Runcode: 2013-08-17716:32:38 ID: Page 3 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.Com by Humberto Bautista (PAR Development) 8/19/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date A Spec House for Mr. & Mrs. Filler Q Multi Family 13 Existing+ Addition/Alteration 8/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this Checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System'Bradford-White M-1400T68N is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC Sys em HVAC 1 must serve only Sleeping Areas. Theri6n c osa le area between zones cannot excde 40'sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 418. ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 262.0 ft' Exposed Slab Floor, 3.500" thick at Bedroom 2 - The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a arete thermostat. In addition the air flow requirements and fan watt draw re uirements in Residential A endix RA3.3 must be met. FIIGH MASS Design - Verify Thermal Mass: 120.0 ft' Covered Slab Floor, 3.500" thick at Living Dining Z=S HIGH MASS Design'- Verify Therinal Mass: • 1;880.0 ft2 Exposed Slab Floor,' 3.500" thick at Living Dining The HVAC System HVAC 4 must serve only Sleeping Areas. The non-closable'area between zones cannot exceed 40 sf and each'zone must have a crate thermostat. In addition the air flow re uirements and fan watt draw =21;;,,n Residential A endix RA3.3 must be met. as HIGH MASS Design - Verify'Theimal Mass: 960.0 ft2 Covered Slab Floor, 3.abedroom N=S HIGH MASS Design - Verify Thermal Mass: 536.0 ft2 Exposed Slab Floor,*1500"•thick at Mastdi bedroom The HVAC System HVAC 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each'zone must have a se crate thermostat. In addition the air flow re uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS -Design-- Verify Thermal Mass. 846:0 ftz CoveredSlab Floor 3.500 thick at Hall,Theater. HIGH MASS Design - Verify .Thermal Mass: 202.0 ft2 Exposed Slab Floor, 3.5y00"' thick at Hall Theater, HERS�REQUIRED VERIFICATION $-~ . Items in this section require field testing and/or verrfication�by a certifled'HERS,Rater. The inspectormust receive a corn leted CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 56CVX070124ACB424 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. . y? The HVAC System HVAC 1 includes credit for verified adequate airflow. 'A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 58CVX090124AC8648 includes credit for a 12.1 EER Condenser. A certified HERS rater must field verify'the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 includes credit for verified adequate airflow. A'certified HERS'rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 58C VX090124A C8648 includes credit for a 12.7 -EER Cdiidenser.,-A=certified=HERS.r-must field verify the installation - of the correct Condenser. CITY O F I A. n i i�� t r A- The HVAC System HVAC 4 incorporates HERS Verified Refrigerant C arge or,a Charge lndica`o�Display.' DEPT. The HVAC System HVAC 4 includes credit for verified adequate airflow. A certified HERSzrater m FIdiagnostically meas re airflow of the HVAC k System. f=s'1't nN1Q-rn1 sr. The'HVAC System HVAC 4 incorporates HERS verified Duct Leakage,'. HERS field vera icatibn an'd'diagn6stic•tes ing is re iiiied to verify that duct leakage meets the specified criteria. 19 DATE -----_ By .. . EnerqyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17716:32:38 I Page 4 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Develonment) 8/19/2nll N PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project NameType A Spec House for Mr. & Mrs. Filler Building ® Single Family ❑ Addition Alone ❑ Multi Family O Existing+ Addition/Alteration Date 1811712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the -special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. N -7 c2i'll pR HER S: REQUIRED UERIoFICATI0N x' ..� a ; Items iri this section r::equ re Held testing and0 yenticatlon.by a certified HERSwRater The inspector must receive a coni leted CF; -.4R form"for each of the;measuces.listed below for final to be iverr: The Cooling, System'.Carrier 58CVX090124ACB648 includes credit for a 12.7 EER Condenser. A certified HERS rater must field verify the installation of:the correct Condenser., The HVACiSystem HVAC 5jncorpotes HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC t System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. CITY O f SUI► DING & S'AFETY DEPT P. UATE �_ By- EnerqyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17716:32:38 fD. Page 5 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 .Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family El Addition Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc Alone Date A Spec House for Mr. & Mrs. Filler ❑ Multi Family ❑ Existing+ Addition/Alteration 8/17/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.96 5.66 -1.70 Space Cooling 57.84 46.88 10.96 Fans 11.46 16.72 -5.26 Domestic Hot Water 6.98 5.01 1.97 Pumps 0.00 0.00 0.00 Totals 80.24 74.27 5.97 Percent Better Than Standard: 7.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 120 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 871 428 Fuel Available at Site: Natural Gas (StM 1,722 688 Raised Floor Area: 0 (NM 1,610 498 Slab on Grade Area: 5,224 (NE) 1,483 411 Average Ceiling Height:.°:'' `';;: 12.6 Roof 5,224 29 Fenestration Average U -Factor: 0.39 TOTAL: 2,054 _...:.._ _ Avera a SHGC`,'. 0.23 Fenestration/CFA Ratio: 39.3% REMARKS < -:y' The, -.Madison Club jml , . .• - '1 a ..... STATEMENT'OF COMPLIANCE Y, Thlscertiflcate ofcomplianceaists'the building features and specifications needed to comply with Title 24 Partst'i the Administrative, Regulations and Part 6 the Efficiency Standards of ft` California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 8/17/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance-forms-and_worksheets, with the specifications, and with any other calculations submitted with this permit application and recognizes that compliance using duct design, and�buildinp � duct sealing,verification of refrigerant charge, insulation Installationquality, envelo a sealing require 9 9 i Duil I )f.V • ,T -9 q n r installer installer testing and certification and field verification by an approved HERS rater:ETY DEPT, IAA ��OVED ' Designer or Owner (per Business & Professi Code) Ins FUR CONSTRUCTION Prest Vuksic Architects Company Address 44-530 San Pablo Ave. Name P,rest Vuksic Architects I DATE 8Y City/State/Zip Palm Desert, Ca 92260 Phone (1760) 779-5393-- Sig,,d_, License # Date Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2013-08-17716:32:38 ID: Page 6 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS-com by Humberto Bautista (PAR Development) 8/19/2013 N CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1811712013 OPAQUES URFACE DETAILS Surface U- Insulation Joint Appendix Tyke Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 677 0.026 R-38 270 20 New 4.2.1-A9 Bedroom 2 Wall 253 0.069 R-21 57 90 New 4.3.1-A6 Bedroom 2' Wall 177 0.069 R-21 115 90 New 4.3.1-A6 Bedroom 2 Wall 216 0.069 R-21 265 90 New 4.3.1-A6 Bedroom 2 (Nall 297 0.069 R-21 295 90 1 New 4.3.1-A6 Bedroom 2 Slab 418 0.730 None 6 180 1 New 4.4.7-A1 Bedroom 2 Slab 262 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 1,990 0.026 R-38 270 20 New 4.2.1-A9 Livin Dinin Wall 96 0.069 0-21 37 90 New 4.3.1-A6 Living Dinin Wall 51 0.069 R-21 120 90 New 4.3.1-A6 Li vin Dining Wall 72 0.069 R-21 151 90 New, 4.3.1-A6 Living Dining Wall 71 0.069 R-21 185 90 New 4.3.1-A6 Livina Dinin Wall 317 0.669 R-21 210 90 New 4.3.1-A6 Livin Dinin Door 24 0.500 None 210 90 New 4.5.1-A4 Livin'q Dining will 224 0.069 R-21 288 90 New 4.3.1-A6 Living Dining Will 149 0.069 R-21 300 90 New 4.3.1-A6 Living Dining FENESTRATION SURFACE DETAILS ID Type Area U Factor SHGC AzmKNGlazing Type Location/Comments 1 Skylight 3.2 0.530 NFRC 0.39 NFRC 270Double Metal Tinted Skylight Bedroom 2 Window 26.6 0.390 NFRC, 0.23 NFRC 115Dual Metal Tinted Bedroom 2 -2- 3 Window ' -147.7 6.390 NFRC 0.23 NFRC 115Dual Metal Tinted Bedroom 2 4, Window 27.5 0.390 NFRC 0.23 NFRC 205Dual Metal Tinted Bedroom 2 5 ,Window .. ,, , 22.6 0.390 NFRC _,0.23 NFRC__ __205Dual Metal Tinted_ .,,,,� Bedroom 2 6 Window' 170.0 0.390 NFRC,d i 0.23 NFRC 205 DualMetal,Tinted if ,+`t k, Bedroom 2 7 lMndow `38.0 0,390NFRC1 '. 0.23 NFRC 205 Dual Metal Tinted, Bedroom 2 8 Skylight 3.2, :0.530 NFRC 0.39 NFRC 270 New.', o;,* Double Metal Tinted Skylight, Living Dining 9 Skylight 312 1.0.530 NFRC = 0.39 NFRC , it 270 New'^, Double Metal Tinted Skylight Living,Dining 10 Skylight $, 13.2; 1 0.530 NFRC i 0.39 NFRC 1 ,270 New. 4 ` Double Metal Tinted Skylight t. Living,Dining if 11 : Window,re a 098.0 ,.0.390 NFRC, X0.23 NFRC ',� x137 New. N-,, Dual Metal Tinted *. i:. Living Diningk--jo, 12 Window 53.0 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 13 Window 55.0 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 14 - Window 105.1 0.396 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining 15 Window 55.0 ' 0.390 NFRC 0.23 NFRC 120 New Dual Petal Tinted Living Dining 16 Window 18.9 0.390 NFRC 0.23 NFRC 120 New Dual Metal Tinted Living Dining (1) ' U -Factor Type: 116-A =Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGCH Window t Wd Ove hang Left Fin Len H t LE ' RExt Dist Len Right Fin H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 None 1.00 ' -�---� 9 None 1.00 10 None 1.00 111 r. , 4 ""° � t INi ,r14 N 11 Bug Screen 0.76 10.0 19.8 5.0 1 0.1 '`5."0114':5ff' SAF r -7-u 12 Bug Screen 0.76 10.0 5.3 10.0 1 6.1 ;0.'0. 13 Bug Screen 0.76 10.0 5.5 10.0 1 0.1 40.,0: 14 Bug Screen 0.76 0.9 18.5 10.0 1 0.1 15 JBug Screen 0.76 10.0 5.3' 10.0 0.1 10.0 10.0 ' 16 IBugg Screen 0.76 ---'.BY . Ener Pro 5.1 by Ener Soft User Number.' 6712 RunCode: 2013-08-17716:32:38 ID: Pae 7 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.com by Humberto Bautista (PAR Development) 8/19/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type O Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8117/2013 OPAQUE SURFACE DETAILS Surface Type Area V Insulation Joint Appendix Factor Cavity Exterior Frame I Interior Frame Azm Tilt Status 4 Location/Comments Wall 120 0.069 R-21 323 90 New 4.3.1-A6 Livin Dinin Slab 120 - 0.730 None 0 180 New 4.4.7-A1 Livin Dinin Slab 1,880 0.730 None 0 180 New 4.4.7-A1 Livin Dinin Roof 1,480 0.026 R-38 270 20 New 4.2.1-A9 Master Bedroom Wall 108 0.069 R-21 30 90 1 New 4.3.1-A6 Master Bedroom Wall 322 0.069 R-21 338 90 1 New 4.3.1-A6 Master Bedroom Wall 32 0.069 R-21 12 90 New 4.3.1-A6 Master Bedroom Wall 278 0.069 R-21 43 90 New 4.3.1-A6 Master Bedroom Wall 113 0.069 R-21 233 90 New 4.3.1-A6 Master Bedroom Slab 960 0.730 1 None 0 180 New 4.4.7-A 1 Master Bedroom Slab 536 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,048 0.026 R-38 270 20 New 4.2.1-A9 Hall Theater Wall 305 0.069 R-21 30 90 New 4.3.1-A6 Hall Theater Wall 40 0.069 R-21 115 90 New 4.3.1-A6 Hall Theater Wall 80 0.069 R-21 120 90 New 4.3.1-A6 Hall Theater Door 23 0.500 None 120 90 New 4.5.1-A4 JHall Theater FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 48.4 0.390 1 NFRC 0.23 NFRC 151 New Dual Metal Tinted Living Dining 18. Window 30.1 0.390 1 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 19 Window' --130.1 0, 3901 NFRC 0.23 NFRC 185 New Dual Metal Tinted Livin q Dinin 20 Window 30.1 0.390 NFRC 0.23 NFRC 185 New Dual Metal Tinted Living Dining 21', Window_ �__ , 30.1 0.390 NFRC . ; _,80:23. NFRC _...,. _ w_ W,,,,,n ._...185 Ne_,. Dual Metal, Tinted,_. ,� Living Dining 22 Window' 'N 30.1 0.390 °NFRC �i .,r�: 0.23' ;NFRC '1 85 New .t� '�, DuaPMetal.4Tinted V:., �' �' �.; Living Dining 23 Window. X30.1 0,390 ,NFRC 1 0.23 NFRC . 185 'New: 1 d Dual Metal Tinted '.L Living Dining 24 Window 23.3-, X0.390,, NFRC 0.23 NFRC '216 New;• m%" Dual Metal Tinted. ' Living Dining 25 window I 149;!0 X0.390 .NFRC e' 0.23 NFRC :,: 7T288 ,,"New: ap " "Dual MetalTinted _ Living,Dining, 26 Window #.264.0;) 0.390 NFRC 0.23' NF,RC.^ 288'New,'-4 °D-ual'Metal;Tinted )t. )I Lipmg;Dlhingti 27 . Windows ► X62.8 0.390 NFRC: ;-' v613 NFRC X288 New . Dual°Meial'Tinted 4-,.,,"` ?11 'iving.DinirigL b 28 Window 18.9 0.390 NFRC'' 0.23 NFRC '300 New" : Dual Metal Tinted Living Dining 29 Skylight` 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom 30, Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom 31 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom 32 ISkylight 1 3.2 • 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom (1) U -Factor Type: 11,6-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len Hot LExt I REM Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0. 76' 24 Bug Screen 0.76 25 Bug Screen 0.76 3.0 48.0 22.0 014-X22.0 22.0 26 Bug Screen 0.76 10.0 26.0 22.0 1 ,r'r22:0• y22.-0• 27 Bug Screen 0.76 10.0 6.2 22.0 b.1 ``''320 j'` 28 Bug Screen 0.76 29 None 1.00 e '`" �i �LS1_r,. 30 None 1.00 /4, __�) U -,.t ` r r J.F,F] M 31 None 1.00 .: f �_ Fr =1 32 Norte 1.00 V UN L 7-p ; ,� - -N, -UN DArE Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2-T3=08-t16:32:38--IjD Page 8 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13,59:17 HERS Provide Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 8/19/2013 Electronically Signed at CalCERTS.COm by Humberto Bautista (PAR Development) 8/19/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1811712013 OPAQUE SURFACE DETAILS Surface V Insulation Joint Appendix Type Area Factor I Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 227 0.069 R-21 250 90 New 4.3.1-A6 Halt Theater Wall 34 0.069 R-21 205 90 New 4.3.1-A6 Hall Theater wall 32 0.069 R-21 210 90 New 4.3.1-A6 Hall Theater Slab 846 0.730 None 0 180 New 4.4.7-A1 Hall Theater Slab 2021 0.730 None 0 180 New 4.4.7-A1 Hall Theater FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Skylight 3.2 0.530 NFRC 0.39 NFRC 270 New Double Metal Tinted Skylight Master Bedroom 34- Window 1.0 0.720 NFRC 0.39 NFRC 338 New Glass Block Master Bedroom 35 Window - 1.0 0.720 NFRC 0.39 NFRC 338 'New Glass Block Master Bedroom 36 Window 1,0 0.720 NFRC 0.39 NFRC 338 New Glass Block Master Bedroom 37,: Window,,,,, 98.1 0.390 NFRC . 0.23 NFRC. 43 New_ Dual Metal_Pnted_W., �,,..,;_ Master Bedroom _V/ 38 Window" ''127.2 0.390 `NFRC ,/ r"- 0.23 NFRC 233 New ) 'Dual Meta1•Tinted f i Master Bedroom 39 Window 08i.0 0;,390 NFRC / 0.23 NFRC 30 New ! Dual Metal Tinted 1 ` _ "Halt Theater 40 Window 34.2_;:0.390'1 NFRC 0.23 NFRC �,4 30 New,'4�o;r Dual Metal Tinted V Hall,Theater' 41 Window 1612 10.390 NFRC 0.23 NFRC V 120 New °' Dual Metal Tinted - Ha11,Theater, 42 Window ,I I,1.0; 0.720 NFRC 0.39 NF,RC_;r ;250 New__ Glass Block It I Hall.Theater !1 43 . WindowA%_1:0 _,0.720 NFRC X0.39 NFRC ` C'.'250 New L. GlassBlockr , Hall'Theater>--jOrb 44 Window' 1.0 0.720 NFRC 0.39 NFRC 250 New Glass Block Hall Theater 45 Window ..196.0 0.390 NFRC 0.23 NFRC 205 New Dual Metal Tinted Hall Theater 4 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LEA RExt Dist Len H t Dist Len H t 33 None 1.00 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76- 39 Bug Screen 0.76 V 1 Y 1 iz I 40 Bug Screen 0.76 N Rt tai r A T 41 Bu Screen 0.76 _ r `-''"' �' �/ ;)=i -T V flr.ra-- I 42 i3bq Screen 0.76 0:31 TF -1 43 Bug Screen 0.76 ( -, ; y I'1,_ Y V ,r - # 44 Bug Screen 0.76 n l.i lV5 (1 t 45 Bug Screen 0.76 ilATr .. 8 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17T16:32:38 ID: Page 9 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, Inc P-lectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 8/19/2013 Electronically Signed at CalCERTS.Com by Humberto Bautista (PAR Development) 8/19/2013 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name A Spec House for Mr. & Mrs. Filler Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Bedroom 2 680 7,480 HVAC 2 & 3 Living Dining 2,000 28,'000 HVAC 4 Master bedroom 1, 496 17, 952 HVAC 5 Hall Theater 1,048 12,576 Totals 1 5,2241 01 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type I Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 •, Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC4 1 Central.Fuihice- 80%-AFUE Split AirConditioner;= °16°0'SEER Setback New HVAC 5y t' 1 Central Furnace V 80%AFtUE S lit'Air Conditioner 16.0 SEERy Setback New jJ y HVAC DISTRIBUTION ill, , � ,��"` 1 ,�i`._ .! System Name Heating 'Ductic—'V Ducts�cL Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 5 DuctedDucted Attic, Ced ing Ins, vented 8.01 0 New WATER HEATING SYSTEMS S stem Name Qt . Type Distribution Rated Tank Input Cap. Btuh) Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M -1-100T6 1 Large Gas No Pipe In _LqalL 85,000 100 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS64, "- ^" `HYDRONIC HE-ATING-$YSTEM PIPING Control Hot Water Piping Length I k. 1— LA UU i I V I A 001 _r IR�o_ & SAFETY DEPT. is t ROVED Plenum Outsi e Burmai Pipe Length Pipe Diameter Insul. Thick. 7QtyHP o BY Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-17716:32:38 ID: Pae 10 of 10 Reg: 213-N0063812A-000000000-0000 Registration Date/Time: 2013/08/19 13:59:17 HERS Provider: CalCERTS, inc