Loading...
04-5956 (AR) Title 24t 0 TITLE 24 REPORT Title 24 Report for: Novotony Residence (Existi 48-775 Avenida FernT La Quinta , CA 922 Project. Designer: 'tiluo &SAFE D SUIT-DI��B®�E®N FDR GDNSTRU ,By pATE� i TROCHE' DESIGN 45-360 DRIFTWOOD DRIVE PALM DESERT, CA 92260 (760) 568-0841 Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 11/11/2003 Toe EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by'EnergySoft, LLC (415) 883-5900. I EnergvPfo 3.1 By EnergvSoft Job Number. 0028.00 .. User Number. 3665 1 48**775 AIDS it h • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Novotony Residence (Existing+Addition) 11/11/2003 Project Title Date 48-775 Avenida Fernando La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check /Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,393 ft2 Average Ceiling Height: 9.6 ft Total Conditioned Slab Area: 6,393 ft2 Building Type: (check one or more) FRI. Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family Existing Plus Addition Front Orientation: (South) 180 deg- Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION Shading Devices Type Orientation Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-21 Roof (R.21.2x10.16) Wood 0.048 Exterior Roof R-11 Wall (W. 1 1.2x4.16) Wood 0.098 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (North) 22.0 0.87 0.70 Bug Screen x❑ ❑ ❑X❑ Rear (Northeast) 41.2 0.87 0.70 Bug Screen x❑ ❑ ❑ x❑ Right (East) 71.5 0.72 0.73 Bug Screen X❑ ❑ ❑ x❑ Right (East) 129.5 0.87 0.70 Bug ScreenX❑ ❑ ❑ X❑ Right _(East) 12.5 0.57 0.67 Bug Screen x❑ ❑ ❑ x❑ Right (East) 72.0 0.55 0.65 Bug ScreenX❑ ❑ ❑ x❑ Right (Southeast) 41.2 0.87 0:70 Bug Screen X❑ ❑ ❑ x❑ Right (Southeast) 16.5 0.72 0.73 Bug Screen X❑ ❑ ❑ x❑ Front (South) 18.8 0.57 0.67 Bug Screen X❑ ❑ ❑ 0 Front (South) 33.0 0.72 0.73 Bug ScreenX❑ ❑ ❑ x❑ Front (South) 54.0 0.55 0.65 Bug ScreenX❑ ❑ ❑ x❑ Front (South) 64.0 0.85 0.70 Bug Screen X❑ ❑ ❑ x❑ Run Initiation Time: 11/11103 09:00:52 Run Code: 10685 005 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: 0028.00 Pa e:3 of 25 • E Certificate of Compliance: Residential (Part 1 of 2) CF -1R NovotonkResidence (Existing+Addition) 11/11/2003 Project Title Date 48-775 Avenida Fernando La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone , Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,393 fl? Average Ceiling Height: 9.6 ft Total Conditioned Slab Area: 6,393 fe Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi-FamilyX❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Tvoe FENESTRATION Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical,.etc.) Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (South) 13.5 0.87 0.70 Bug Screen X❑ ❑ ❑ x❑ Front (Southwest) 27.5 0.87 0.70 Bug Screen Q ❑ ❑ 0 Left (West) 48.0 0.55 0.65 Bug Screen Q ❑ ❑ Q Left (West) 75.0 0.85 0.70 Bug Screen Q ❑ ❑ Q Rear (North) 250.0 0.80 0.65 Bug Screen x❑ ❑ ❑ X❑ Rear (North) 260.0 0.80 0.65 Bug Screen ❑ 0 ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 11111/0309:00:52 Ru Code: 1068570062 Ener Pro 3.1 _By Ener Soft User Number: 3665 Job Number: 0028.00 Pa e:4 of 25 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Novotony Residence (Existing+Addition) 11/11/2003 • Project Title Date 1] 1] HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments rant al EUrnam- 76% AFUE Ducts in Attic 4.2 Setback Entire Residence Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 10.0 SEER Ducts in Attic 42 Sethark FntirA RPsidpnce WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (°/a) R -Value Standard Gas 100 gal Small Gas Standard Standard Gas 75 gal. Small Gas Standard 1 40-000 2 40.000 100 50 0.53 n/a 0.53 n/a 12 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: TROCHE' DESIGN Address: 45-360 DRIFTWOOD DRIVE PALM DESERT, CA 92260 Telephone: (760) 568-0841 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 I I 11 O (signat (date) IEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Paae:5 of 25 Certificate of Compliance: Residential (Addendum) CF -1 R Novotony Residence (Existing+Addition) 11/11/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oasea on the aaequacy OT the special iusurication ano aocumentation sunmittea. Plan Field The DHW System "Standard Gas 100 gal. " Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The DHW System "Standard Gas 75 gal." Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic. testing of these measures on a form CF -6R. I EnergvPro 3.1 By EnergySoft User Number. 3665 Job Number. 0028.00 Page:6 of 25 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into • the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a'§ 150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturers labeled R -Value. a§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does * not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and forth. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality. standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. a§ 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Page:7 of 25 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into _ the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures it applicable. DESIGNER ENFORCEMENT jed) iections 601, in 3 system eal openings ties shall not I not be is and ials other uilding all not be adhesive ianually ioisture, be suitable r foam fielding resistance ioor pools or or greater for )Ie lighting efficacy of •ement !8.00 Page:8 of 25 Computer Method Summary 6,393 ft Floor Construction Type: ❑ (Part 1 of 3) C-2R _Noyato.n_yJ3eside.ace_(Existing±Addition) Single Fam Detached . 11 /11 /2003 �Project Title �8_ ; &venida-F-e.r_nando—La_Qu.inta (South) 180 deg Total Fenestration Area: Date Project Address 1.00 Total Conditioned Volume: Building Permit # ALR-C-0_N.D-MON (713 1 (760) 346-0855 _RREEZE Documentation Author BUILDING ZONE INFORMATION Telephone Plan Check/Date -Gomputermance Floor Area Volume 15 Field Check/Date Compliance Method (Package or Computer) r,= s1373 Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Existing+Addition Budget Adjustment Space Heating 3.02 4.18 -1.16 Ratio F: 6220 / 6393 = 0.973 Space Cooling 32.17 71.99 -39.82 Budget Adj: 0.973 X 185.54 - 40.75) = 43.58 Domestic Hot Water 4.46 7.05 -2.59 The budget shown to the left has been increased using Totals 43.58+ 39.66 = 83.23 83.23 0,01 this Budget Adjustment based upon Existing building information shown on the C -2R which follows this form. than Standard: 0.0% Total Conditioned Floor Area: - 6,393 ft Floor Construction Type: ❑ Raised Floor 0 Slab Floor Building Type: Single Fam Detached . Building Front Orientation: (South) 180 deg Total Fenestration Area: 19.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 61,373 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 6,393 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area _EnticeBesidence r,= s1373 100 r'nnditinnadRetbask _2 n/ OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Rnof _6.220 3.04$ 340 Wall 48 3_098_ 0 g0 Wall _____13Z _00,98- —40 g0 Mall_ _18A 0"098_ 20 ___90_ Mall— _132 3.098 _130 9Q _WA l_ 689_ 0_o.9B_ X6.0 _9.0 Wall 72 � OQ0 325 00 Wall 1,1513_0$ _270 ____90_ Rnof 23_ 0.04$ —340 0 (all— _230 __DM.8_ 0 9D_ Solar Gains Y / N Form 3 Reference Location / Comments EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0028.00 Pace:9 of 25 1 Computer Method Summary (Part 2 of 3) C -2R Novotony Residence (Existing+Addition) 11/11/2003 1project Title Date "FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments J- Window Bear (Nodh) _22_0_ -0-8Z0_ 070 0 An Default lace Metal Frame Fntire Residence 2 Window Rear (Northeast) 13.8 0.870 0.70 45 90 Default Glass Metal Frame Entire Residence 3 Window Rear (Northeast) 27.5 0.870 0.70 45 90 Default Glass Metal Frame Entire Residence 4 Window Right (East) 33.0 0.720 0.73 90 90 Default Glass Metal Frame Entire Residence 5 Window Right (East) 85.5 0.870 0.70 .90 90 Default Glass Metal Frame Entire Residence 6 Window Right (East)_ 6.2 0.570 0.67 90 90 Default Glass Non Metal Frame Entire Residence L Window Right (East)_ 24.0 0,550 65 90 90 Default Glass Non Metal Frame Entire Residence 8 Window Right (East) 44.0 0.870 0.70 90 90 Default Glass Metal Frame Entire Residence 5 Window Right (East) 24.0 0,550 0.65 90 90 Default Glass Non Metal Frame Entire Residence 1Q Window Right (East) 38.5 0.720 0.73 90 90 Default Glass Metal Frame Entire Residence Window Riqht (East) 6.2 0.570 0.67 90 90 Default Glass Non Metal Frame Entire Residence 12 Window Right (East) 24.0 0.550 0.65 90 90 Default Glass Non Metal Frame Entire Residence 13 Window Riaht (Southeast) 1-3-8- 0,870 0.70 135 90 Default Glass Metal Frame Entire Residence 14 Window Right (Southeast) 16.5 0.720 0.73 135 90 Default Glass Metal Frame Entire Residence 15 Window Right (Southeast) - 13.8 0.870 0.70 135 90 Default Glass Metal Frame Entire Residence 16 Window Right Southeast) 13.8 0.870 0.70 135 90 Default Glass Metal Frame Entire Residence 17 Window Front (South) 6.2 0.570 0.67 180 90 Default Glass Non Metal Frame Entire Residence 18 Window Front (South) 33.0 0.720 0.73 180 90 Default Glass Metal Frame Entire Residence 19 Window Front (South) 54.0 0,550 0.65 180 90 Default Glass Non Metal Frame Entire Residence 20 Window Front (South) 6.2 0.570 0.67 180 90 Default Glass Non Metal Frame Entire Residence Ti Window Front (South) 6.2 0.570 0.67 180 90 Default Glass Non Metal Frame Entire Residence 22 Window Front (South) 64.0 0.850 0.70 180 90 Default Glass Metal Frame Entire Residence 23 Window Front (South) 13.5 0.870 0.70 180 90 Default Glass Metal Frame Entire Residence 24 Window Front (Southwest) 13.8 0.870 0.70 225 90 Default Glass Metal Frame Entire Residence 25 Window Front (Southwest) 13.8 0.870 0.70 225 90 Default Glass Metal Frame Entire Residence 26 Window Left (West) 24.0 0.550 0.65 270 90 Default Glass Non Metal Frame Entire Residence 27 Window Left (West) 64.0 0.850 0.70, 270 90 Default Glass Metal Frame Entire Residence Window Left (West) 24.0 0.550 0.65 270 90 Default Glass Non Metal Frame Entire Residence �P9 Window Left (West) 11.0 0.850 0.70 270 90 Default Glass Metal Frame Entire Residence INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 2 Buq Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 Biu Screen 0.76 0.0 0.0 0.0 - 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 6 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 7 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 8 Bug Screen 0.76 0.0 10.0 0.0 0.0 0.0 0.0 9 Bug Screen -.0.76 0.0 0.0 0.0 0.0 0.0 0.0 10 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 11 Bug Screen 0.76 0.0 0.0 0.0 0.0 - 0.0 0.0 12 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 13 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 14 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 15 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 16 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 17 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 18 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 19 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 20 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 21 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 22 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 23 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 24 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 _ 25 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 26 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 27 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 8 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 _ EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0028.00 Paoe:10 of 25 1 Computer Method Summary (Part 2 of 3) C -2R Novotony Residence (Existing+Addition) 11/11/2003 -Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 3Il Wind ow Rear (North _10.0_0 �8Il0 065 0_ AD Manditory Valuay(AddPd Glacg�L Entire RPcjdpIInp 31 Window Rear (North) 100.0 0.800 0.65 0 90 Manditory Values (Added Glass) Entire Residence 32 Window Rear (North) 160.0 0.800 0.65 0 90 Manditory Values (Added Glass) Entire Residence 33 Window Rear (North) 150.0 0.800 0.65 0 90 Manditory Values (Added Glass) Entire Residence INTERIOR Window Hgt. Wd. 0.0 0.0 0.0 0.0 Overhang Len. Hgt. LExt. RExt. 0.0 0.0 0.0 0.0 Left Fin Dist. Len. Hgt. Dist. Len. I EnergvPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Paae:11 of 25 1 INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 30 Bug Screen 0.76 31 Buy Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 Window Hgt. Wd. 0.0 0.0 0.0 0.0 Overhang Len. Hgt. LExt. RExt. 0.0 0.0 0.0 0.0 Left Fin Dist. Len. Hgt. Dist. Len. I EnergvPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Paae:11 of 25 1 Computer Method Summary (Part 3 of 3) C -2R Novotony Residence (Existing+Addition) 11/11/2003 AllillikProiact Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 37 0.76 0.0 0 Entire Residence S.Iab-Eerimeter —4$ QZ& --O–Q 0 Entire Residence HVAC SYSTEMS Heating Equipment Minimum Distribution Type ' Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 76°6 AFUE Ducts in Attic 4.2 Setback Entire Residence aydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 10.0 SEE Ducts in Attic 4.2 Setback Entire Residence WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 100 gal. Small Gas Standard 1 40.000 100 0.53 n/a 12 Standard Gas 75 gal. Small Gas Standard 2 40.000 50 0.53 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMA I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Paaa-12 of 25 I • Computer Method Summary (Addendum) 2-2R Novotony Residence (Existing+Addition) 11/11/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justmcation and documentation submitted. Plan Field The DHW System "Standard Gas 100 gal. " Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The DHW System "Standard Gas 75 gal." Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0028.00 Paae:13 of 25 1 Computer Method Summary (Part 1 of 3) C-2R Noyato.ny Be. s.i.de.ace_(Existi.ng) 11 /11 /2QQ3 Project Title 8--7' &venid.a-Fe.mando_La_Q.u.inta Date Project Address Building Permit # BBEEZE-AIL-CO_NDJnQNl (73 (760) 346-0855 Documentation Author Telephone plan Check/Date S�mp� ERerforrrm.anCP 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.18 4.09 -0.90 Space Cooling 32.99 74.21 -41.22 Domestic Hot Water 4.58 7.25 -2.67 Totals 40.75 85.54 -44.79 Percent better than Standard: Existing Building Information Total Conditioned Floor Area: - 6,220 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 18.1% Number of Dwelling Units: 1.00 Total Conditioned Volume: 59,712 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 6,220 ft 2 r� i� BUILDING ZONE INFORMATION Zone Name Floor Area Volume # of Units .Entire-Residen.cP s,22 —59,712 100 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Solar Gains Y / N Form 3 Reference Thermostat Vent Zone Type Type Hgt. Area rnnditinned SPthack 2 n/a Location / Cnmments Computer Method Summary (Part 2 of 3) C -2R Novotony Residence Existing) 11/11/2003 ,Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments -I- Window -Rear (61odb) -38_5_ 02-M 0.73 0 90 Default Glass Metal Frame Entire Rec_idencn 2 Window Rear (North) 155.0 0.850 0.70 0 90 Default Glass Metal Frame Entire Residence 3 Window Rear North 27.5 0.870 0.70 0 90 Default Glass Metal Frame Entire Residence 4 Window Rear (North) 72.0 0.850 0.70 0 90 Default Glass Metal Frame Entire Residence 5 Window Rear (North) 22.0 0.870 0.70 0 90 Default Glass Metal Frame Entire Residence 6 Window Rear (Northeast) 13.8 0.870 0.70 45 90 Default Glass Metal Frame Entire Residence 2 Window Rear ( ort east) 11.0 0.870 0.70 45 90 Default Glass Metal Frame Entire Residence 8 Window Rear (Northeast) 13.8 0.870 0.70 45 90 Default Glass Metal Frame Entire Residence 6 Widow Rear • ( N ort heast) 27.5 0.870 0.70 45 90 Default Glass Metal Frame Entire Residence JD Window Right (Eas_ 21 2 0.550 0.65 90 90 Default Glass Non Metal Frame Entire Residence 11 Window Right (East) 6.0 0.570 0.67 90 90 Default Glass Non Metal Frame Entire Residence 12 Window Right (East 33.0 0.720 0.73 90 90 Default Glass Metal Frame Entire Residence 13 W.ind.Qw_t3ight (.East)_ -&5a 0.870 0.70 90 90 Default Glass Metal Frame Entire Residence 14 Window Right (East) 6.2 0.570 0.67 90 90 Default Glass Non Metal Frame Entire Residence 15 Window Right (East) - 24.0 0.550 0.65 90 90 Default Glass Non Metal Frame Entire Residence 16 Window Right _(Eastj 44.0 0.870 0.70 90 90 Default Glass Metal Frame Entire Residence 17 Window Right (East 24.0 0.550 0.65 90 90 Default Glass Non Metal Frame Entire Residence 18 Window Right (East) 38.5 0.720 0.73 90 90 Default Glass Metal Frame Entire Residence 19 Window Right (EaSU) 6.2 0.570 0.67 90 90 Default Glass Non Metal Frame Entire Residence 20 Window Right (East) 24.0 0.550 0.65 90 90 Default Glass Non Metal Frame Entire Residence 21 Window Right (Southeast) 13.8 0.870 0.70 135 90 Default Glass Metal Frame Entire Residence 22 Window Right (Southeast) 16.5 0.720 0.73 135 90 Default Glass Metal Frame Entire Residence 23 Window Right (Southeast) 13.8 0.870 0.70 135 90 Default Glass Metal Frame Entire Residence 24 Window Right (Southeast) 13.8' 0.870 0.70 135 90 Default Glass Metal Frame Entire Residence 25 Window Front (South) 6.2 0.570 0.67 180 90 Default Glass Non Metal Frame Entire Residence 26 Window Front (South) 33.0 0.720 0.73 180 90 Default Glass Metal Frame Entire Residence 27 Window Front (South) 54.0 0.550 0.65 180 90 Default Glass Non Metal Frame Entire Residence 8 Window Front (South) 6.2 0.570 0.67 180 90 Default Glass Non Metal Frame Entire Residence Window Front (South) 6.2 0.570 0.67 180 90 Default Glass Non Metal Frame Entire Residence INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 2 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 6 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 7 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 8 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 9 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 10 Bug Screen 0.76 0.0 0.0 0.0- 0.0 0.0 0.0 11 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 12 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 13 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 14 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 15 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 16 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 17 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 18 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 19 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 20 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 21 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 22 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 23 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 24 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 25 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 26 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 27 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 ' 0.0 0.0 0.0 0.0 W2928 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paae:15 of 25 1 Computer Method Summary (Part 2 of 3) C -2R Novotonv Residence (Existing) 11/11/2003 Wroject Title Date FENESTRATION SURFACES # Type IQ 31 VYjariQW_ELQf.It_(SO.LLth) Window Front (South) 32 Window Front (Southwest) 33 Window Front (Southwest) 34 Window Left (West) 35 Window Left _(West) 36 Window Left ---(West) 37 Window Left (West) -aft Window Leftorthwest) Entire Residence M Window Left (_orthwest) 90 Default Glass Metal Frame Entire Residence 24.0 0.550 0.65 270 90 Default Glass Non Metal Frame Entire Residence 11.0 0.850 0.70 270 90 Default Glass Metal Frame Entire Residence 13.8 0.870 0.70 315 90 Default Glass Metal Frame Entire Residence 27.5 0.870 0.70 315 90 Default Glass Metal Frame Entire Residence Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 36 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 39 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 U_ Act. Glazing Type Location/ Area Factor SHGC Azm. Tilt Comments ___6_4_D_ _0.850 n_70 180 qQ Default ,lass Metal Frame Entire Residence 13.5 0.870 0.70 180 90 Default Glass Metal Frame Entire Residence 13.8 0.870 0.70 225 90 Default Glass Metal Frame Entire Residence 13.8 0.870 0.70 225 90 Default Glass Metal Frame Entire Residence 24.0 0.550 0.65 270 90 Default Glass Non Metal Frame Entire Residence 64.0 0.850 0.70 270 90 Default Glass Metal Frame Entire Residence 24.0 0.550 0.65 270 90 Default Glass Non Metal Frame Entire Residence 11.0 0.850 0.70 270 90 Default Glass Metal Frame Entire Residence 13.8 0.870 0.70 315 90 Default Glass Metal Frame Entire Residence 27.5 0.870 0.70 315 90 Default Glass Metal Frame Entire Residence INTERIOR AND EXTERIOR SHADING Window # Exterior Shade Twe SHGC Hgt. Wd. 31 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 32 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 33 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 34 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 35 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 __U 36 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 37 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 36 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 39 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 16 of 25 1 Computer Method Summary (Part 3 of 3) C -2R Novotony Residence (Existing) 11/11/2003 A1111111110roject Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 40 0_76 0.0 0 Entire Residence SJab2umeter X52 -0_7_6 0.0 0 Entire Residence HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 76°a AFUE Ducts in Attic 4.2 Setback Entire Residence f *ydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type VComments Split Air Conditioner 10.0 SEER Ducts in Attic 4.2 Setback Entire Residence WATER HEATING SYSTEMS Rated' Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery 1 Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 100 gal. Small Gas Standard 1 40.000 100 0.53 , n/a 12 Standard Gas 75 gal. Small Gas Standard 2 40.000 50 0.53 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. RKS 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Novotorly Residence(Existing +Addition 11/11/2003 SYSTEM NAME FLOOR AREA Entire Residence 6,393 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 4 Heating System Output per System 80,000 Total Output (Btuh) I 320,000 Output (Btuh/sgft) I 50.1 Cooling System Output per System 60,000 Total Output (Btuh) 240,000 Total Output (Tons) - 20:0 Total Output (Btuh/sgft) 37.5 Total Output (sgftrron) 319.6 Air System CFM per System 2,000 Airflow (cfm) 8,000 Airflow (cfm/sqft) 1.25 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 13,446 159,671 25,752 3,862 145,933 0 7,984 7,297 0 0 0 0 0 0 0 0 0 7,984 7,297 175,6378[773;:;2 160 526 Existing Heat/Cool System (5 Ton) 138,462 92,901 320,000 Total Adjusted System Output 188,462 92,901 320,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 69.2 of 105.0 of 105.0 of 07 Supply Air Ducts Outside Air e 0 cfm Heating Coil Supply Fan 104.2 of 8000 cfm ROOMS 70.0 of 69.2 OF i 14.1 / 80.3 of Outside �� 0 cfm 78.9/70.6 of 1% Return Air Ducts ; 78.9/70.60F = 67.0/66.10F Cooling Coil Supply Fan 8000 cfm 67.0 / 66.1 of Supply Air Ducts 67.9 / 66.4 of 68.7% R.H. ROOMS 78.0 / 70.3 of Return Air Ducts `S L EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Page: 18 of 25 ROOM LOAD SUMMARY EnergyPro 31 By Energysoft User Number. 3665 Job Number. 0028.00 Page: 19 of 25 PROJECT NAME NovotoIiy Residence Existin +Addition DATE 11/11/2003 YSTEM NAME Entire Residence FLOOR AREA 6,393 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Entire Residence Entire Residence (Existing) 1 11,473 136,242 25,055 11,473 136,242 25,055 3,292 124,375 (Addition) 1 1,973 23,429 697 1,973 23,429 697 571 21,558 A PAGE TOTAL 1 13,446 159,671 25,752 .3,862 145,933 TOTAL 1 13,446 159,671 25,752 3,862 145,933 EnergyPro 31 By Energysoft User Number. 3665 Job Number. 0028.00 Page: 19 of 25 ROOM HEATING PEAK LOADS oject Title nvntnnv RasirlPnr.P (FXictinn+Adrlitinnl Date 11 /11 /gnn3 Room Information Design Conditions Room Name Entire Residence (E)dsting) Time of Peak Jan 12 am Floor Area 6,2201 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction Area x x x X X X x x x X x X X X x x x x X X X X X x x X x x x X x X x x x X x x x U -Value X x X X X X x x X x X X x X X X X x X X X X X x X X X X x x X X x X x x X x X AT OF. = = = = = = = = = = = = Btu/hr 6,220.0 0.0478 46.0 13,679 3,008.8 0.0978 46.0 13,537 275.0 0.8700 46.0 11,006 121.0 0.7200 46.0 4,008 31.2 0.5700 46.0 819 174.0 0.5500 46.0 4,402 139.0 0.8500 46.0 5,435 perimeter = 485.0 45.5 22,068 Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: I 74,9531 Infiltration: 1.0o x 1.oao x s zzo x s.so x 1.00 / 601 x as = as a22 Schedule Air Sensible, Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 1 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0028.00 Page: 20 of 25 ROOM HEATING PEAK LOADS '10,P Ft Title Date otonv Residence -(Ex istin +Addition) 111/11/2003 Room Information Design Conditions Room Name (Addition) Time of Peak Jan 12 am Floor Area 173 Outdoor Dry Bulb Temperature 24 OF Indoor. Dry Bulb Temperature 70°F Conduction Area 11_valuP AT oG R*ii/hr 173.0 X x X X X X X x x X x X x X X x X X X x X X x x X X X X x x X x X x X X X X X 0.0478 x X X X X X X X X X X X x X x X X X x X X x X X x x X X X X X X X X X X X X X 46.0 = = = 380 230.0 0.0978 46.0 1,035 510.0 0.8000 46.0 18,768 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 20 183 Infiltration: �cnedu e0 X Air Sensible x Area173 x Ceiling Height ACH 00 s] X OT 46 = 1 375 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21 EnergyPro 3.1 By EnergySoR User Number. 3665 Job Number. 0028.00 Page: 217,f:275 • Cl u RESIDENTIAL ROOM COOLING LOAD SUMMARY Novotony Residence -( +Addition) 11/11/2003 Project Title Date Room Name Entire Residence (Existing) Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 0F Design Temperature Difference: 370 F Conduction IR -21 Roof (R.21.2x10.16) Area U -Value X X X X X X X X 0. X X X X X X X DETD 1 = = = = = = = Btu/hr 56.0 16,653 35.6 10,477 37.0 8,852 37.0 3,223 37.0 659 37.0 3 541 37.0 1 4.372 X X 1. Design Equivalent Temperature Difference (DETD) Page Total 47,777 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr O erMtCsmnt (J) (North) perNltCsmnt (E) (Northeast) O erMtCsmnt K (Northeast) FxMetal Z (East) (2) OperMtCsmnt (BB) (East) FxNonMetal B (East) FrnchDr 21 (East) O erMtCsmnt C (East) FrnchDr 41 (East) FxMetal F East ( 0.0 X1 x x X x X X X X X + + + + + + + + + + 22.0 X x X X x X X X X x 15 ) X X x X x 0.779 = = = = = = = = __ = 257 ( 0.0 1 13.8 48)x 0.779 514 ( 0.0 1 27.5 48) 0.779 1,029 ( 0.0 1 33.0 73) 0.813 1,958 ( 0.0 1 85.5 73)X* 0.779 4,864 ( 0.0 1 6.2 73)X 0.746 340 ( 0.0 1 24.0 73) 0.724 1,268 ( 0.0 1 44.0 73)X 0.779 2,503 ( 0.0 1 24.0 73)X 0.724 1,268 ( 0.0 1 38.5 73) 0.813 2,284 Sched. Page Total 1 16,284 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 6,220 x 0.500 Watts/sgft x 3.41 Btuh/Watt = 10,614 Occupants 1.00 X 6,220 x 255 Btuh/OCC. / 333 sgft/occ. = 4,763 Receptacle 1.00 X 6,220 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 X 6,220 x 0.000 Watts/sqft X 3.41 BtuhlWatt = 0 Infiltration:, E:Ii�o X 1.080 x s,22o x x / 60] 0 = Schedule Air Sensible Area Ceiling Height ACH L\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 136242 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 6 220 X 225 Btuh/OCC. I 333 sgft/OCc. = 4 203 Receptacle 1.00 x 6 220 x 0.000 Watts/sqft x 3.41 BtuhfWatt = o Process 1.00 X 6 22o x 0.000 Watts/sqft X 3.41 Btuh/Watt = o Infiltration: [1.00 X 4 840 X 6 22 x 9.60 X 1.00 /601 1 0.00433 = 20 853 Schedule Air Latent Area Ceiling Height ACH Z�W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 25,055 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Page: 22 of 25 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Novotony Residence (Existing+Addition) 11/11/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X. X X X X X X X X Entire Residence (Existing) 78DF 115DF 37DF DETD 1 X X X X X X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 01 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation ' Area SGF Area SGF SC Btu/hr FxNonMetal (East) chDt(AS (East) O erMtCsmnt DD Southeast FxMetal D (Southeast) OperMtCsmnt (G) (Southeast) O erMtCsmnt L (Southeast) FxNonMetal CC (South) FxMetal EE (South) FrnchDr I (South) FxNonMetal A South ( 0.0 X1 X X X x X X1 X X x + + + + + + + + + 4:1 6.2 X x X x x X X X X x 73 ) X )x )x x X X x 0.746 = = = = = = = = = = 340 ( 0.0 1 24.0 73 0.724 1,268 ( 0.0 1 13.8 62)x 0.779 664 ( 0.0 1 16.5 62 0.813 831 ( 0.0 1 13.8 62) 0.779 664 ( 0.0 1 13.8 62) 0.779 664 ( 0.0 6.2 32)'X 0.746 149 ( 0.0 1 33.0 32) 0.813 858 ( 0.0 1 54.0 32)X 0.724 1,250 ( 0.0 1 6.2 I 32) 0.746 149 Sched. Page Total 1 6.8391 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 6,220 x 0.500 Watts/sgft x 3.41 Btuh/Waft = 10,614 Occupants 1.00 x 6,220 x 255 Btuh/occ. / 333 sgft/occ. = 4,763 Receptacle 1.00 X 6,220 X 0.000 Watts/sgft X 3.413 Btuh/Waft = 0 Process 1.00 x 6,220 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0 Infiltration: � 1.0o x L�0_8 X s,22o x x / 60] 0 =1. 39-7521 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 136,242 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 6 220 x 225 Btuh/occ. / 333 sgft/occ. = 4 203 Receptacle 1.00 X 6 220 X 0.000 Watts/sgft X 3.41 Btuh/Waft = o Process 1.00 X 6 220 X 0.000 Watts/sgft X 3.41 BtuhtM/aft = Infiltration: [ X 4 840 X 6 22 X Height X 60] 0.00433 = 20 853 Schedule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 25,055 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0028.00 Page: 23 of 25 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Novotony Residence (Existing+Addition) 11/11/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Entire Residence (Existing) 78°F 115°F 37°F Conduction Area U -Value , DETD 1 Btulhr X X X X X X X X X X = X - X - X - X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxNonMetal Y) (South) WSWDt(49 (South) 0 erMtCsmnt N (South) 0 erMtCsmnt FF (Southwest) OperMtCsmnt (M) (Southwest) FrnchDr 42 (West) MtSIdDr 13 (West) FrnchDr 20 (West) MtSIdDr P (West) 0.779 337 ( 0.0 X X X X x X1 X X X x 1 + 1 + 1 + 1 + ' 1 + + 1 + 1 + 1 + + 6.2 X X x x X X X X X x 32 ) X )x x X X ) X )x 0.746 = = = = = = = = __ = 149 ( 0.0 64.0 32 0.779 1,596 ( 0.0 13.5 32)x 0.779 337 ( 0.0 13.8 62)x 0.779 664 ( 0.0 13.8 62) 0.779 664 ( 0.0 24.0 73) 0.724 1,268 ( 0.0 64.0 73) 0.779 3,641 ( 0.0 24.0 73)X 0.724 1,268 ( 0.0 11.0 7 0.779 626 ( Sched. Page Total 10 12 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 6,220 X 0.500 Wafts/sqft x 3.41 Btuh/Waft = 10,614 Occupants 1.00 X 6,220 X 255 Btuh/OCC. / 333 sgftlocc. - 4,763 Receptacle 1.00 X 6,220 X 0.000 Wafts/sgft X 3.413 BtuhlWaft = 0 Process 100 x 6,220 x 0.000 Wafts/sqft X 3.412 Btuh/Waft = o Infiltration: 1.00 x 1 1.001 x 27 x x / 60] Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 136242 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 6 220 X 225 Btuh/OCC. I 333 sqft/occ. = 203 Receptacle 1.00 X 6 220 X 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Process 1.00 X 6 220 X 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Infiltration: [ 1.00 x844 0 x 622 x 9.60 x 1.00 / 60] 0.00433 = 20853 Schedule Air Latent Area Ceiling Height ACH �W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 25,055 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0028.00 Page: 24 of 25 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Novotony Residence (Existing+Addition) 11/11/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: (Addition) 780F 115°F 37°F Conduction Area U -Value DETD 1. Btu/hr x 56.0 = 463 x 35.6 = 801 x 37.0 = 15,096 x = x = x = x = x = X = 1. Design Equivalent Temperature Difference (DETD) Page Total 16 360 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr MtSIdDr New (North) ( 0.0 X 1 + 100.0 X 15)X 0.724 = 1,085 tSIML(N )_ (North) ( 0.0 x 1 + 100.0 x 15)X 0.724 = 1,085 MtSIdDr New (North) ( 0.0 x 1 + 160.0 X 15)X 0.724 = 1,737 MtSIdDr New (North) ( 0.0 x 1 + 150.0 X 15)x 0.724 = 1,628 ( X + X )x ( X + X )x ( x + X )x ( X + X )x ( X + X )x Sched. Page Total 1 5,535 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 173 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 295 Occupants 1.00 X 173 X 255 Btuh/OCC. / 333 sgft/occ. = 132 Receptacle 1.00 x 173 x 0.000 Watts/sqft x 3.413 Btuh/Waft = 0 Process 1.00 x 173 x 0.000 Watts/sgft x 3-412 Btuh/Waft = 0 Infiltration: oo1 x x 0 x x / 60] 0= Schedule Air Sensible Area Ceiling Height ACH z�T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,429 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 173 x 225 Btuh/OCC. I 333 sgft/occ. = 17 Receptacle 1.00 x 173 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Process 1.00 x 173 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: 1 ool x 4 840 x 17 x 9.60 x 1.00 / 60] 0.00433 = 580 Schedule Air Latent Area Ceiling Height ACH Z -\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 697 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0028.00 Page: 25 of 25