BSOL2015-0233 Revision 3 Solar Plans4 AHJ NOTES PLAN SET LEGEND ABBREVIATIONS PROJECT INFORMATION E EXTERIOR MSP MAIN SERVICE PANEL 74 X 327 W SUNPOWER SPR-327-NE-WHT-D (0 e ALL CONDUIT TO RUN ON (E) EXISTING _01111111b'-0,' E m OF HOUSE UNLESS OTHERWISE NOTED .:,,, ROOF MOUNTED SOLAR o o ° ; �d SUB SUB SERVICE PANEL (N) NEW PHOTOVOLTAIC MODULES OCCUPANCY: R-3 ..:. EXT EXTERIOR 2 X 5000 W SMA America SB5000TL-US-22 Lu',° y 0) n �' CONSTRUCTION TYPE: VB AC AC DISCONNECT (240V) z ¢ aw UNSPRINKLERED INT INTERIOR 2 X 6000 SMA America SB6000TL-US-22 ' DC DC DISCONNECT (240V) SLC SOLAR LOAD CENTER EMT. ELECTRICAL METALLIC TUBING SYSTEM SIZE: 24.198 kW DC STC � a o U RMT RIGID METALLIC TUBING ARRAY AREA: 1302 SF N 8 MONITORING METER IJJ VOC VOLTAGE OPEN CIRCUITS 0) INV INVERTER POWER AHJ: CITY OF LA QUINTA E J VMP VOLTAGE AT MAX. APN: 658-300-001 JB JUNCTION BOX ISC SHORT CIRCUIT CURRENT Z JEANNE THERESE m.: 0 CB COMBINER BOX IMP CURRENT AT MAX. POWER 48775 AVENIDA FERNANDO > to rq FLEXIBLE METALLIC NTS NOT TO SCALE LA QUINTA, CA 92253it a FMC CONDUIT 7Z APPLICABLE CODE—)p � VICINITY MAP Q ALL WORK TO COMPLY WITH p tS�aN THE FOLLOWING CODES: f BUILDING CODE UINTA F 013 CA RESIDENTIAL CODE 013 CA MECHANICAL CODE W E W013 '�IG & SAEEN D P CA ELECTRICAL CODE' 013 CA GREEN CODE "� o = QAR-PROVED w N FOR CONSTRUCTIOA - - LL ` ' 013 CA PLUMBING CODE o o ¢ a BY 013 CA ENERGY CODE - Z w a _-- _ SITE .---�� 013 CA FIRE CODE o Z w Q Z o (g � 48775AvenveFePnpmdo -SHEET INDEX fir• Q �- ]. "'! 6i N ... _� ... PV -1 PROJECT INFORMATION o a y£ • !;- e� %dna-0f o: i • - .. STmace4 t - - f PV -1A SITE PLAN, HOUSE PHOTO PV -2 ROOF PLAN a ' uPalm Spm+ga lours ,4S .ti 'i - �0 PV -2A ATTACHMENT DETAILS PV -26 OTHER DETAILS O a o PV -3 ELECTRICAL LINE DIAGRAM & /� o ELECTRICAL CALCULATIONS �.. o F PV -3A ELECTRICAL NOTES, LOAD CALCSj ww PV -4 REQUIRED SIGNAGE U a O PV -1 r�� RO AN MSP SIZE IS AN (E) 400 A ATTACHMENT POINTS: 48" O.C. MAX ARRAY 7 8 SOLAR MODULES 16 ATTACHMENTS @ 48" O.C. MAX. �� ARRAY 6 \ 12 SOLAR MODULES 32 ATTACHMENTS \ @ 48" O.C. MAX. INTERIOR TRUSS DIAGONAL, TYP. 3/4" PVC CONDUIT, TO RUN IN ATTIC AND UNDER EAVES ARRAY 3 6 SOLAR MODULES 12 ATTACHMENTS @ 48" O.C. MAX. 1 1/4" PVC CONDUIT, TO RUN IN ATTIC AND UNDER EAVES B FIRE ARRAY 8 10 SOLAR MODULES 0 18 ATTACHMENTS 48" O.C. MAX. `\ o co ^ 3 ����\ �\ �� ��\ • FIRE ACCESS POINT R5 4'-2' '�-ARRAY 5 16 SOLAR MODULES 42 ATTACHMENTS ^ @ 48" O.C. MAX. o� ARRAY 4 4 SOLAR MODULES 16 ATTACHMENTS @ 48" O.C. MAX. .'\Q; �N rn rn ARRAY 9 ARRAY 2 o 1 SOLAR MODULES 8 SOLAR MODULES 4 ATTACHMENTS 18 ATTACHMENTS 2-S" Cal 48" O.C. MAX. @ 48" O.C. MAX. Plane 1 Type: CONC S TILE Framing: 2x8 RAFTERS @ 24" o.c Azimuth (deg): 155 Slope (deg): 15 Area (so: 326 Azimuth (deg): 155 Tilt (deg): 15 Area (so: 158.4 iverage of Roof 1 48.6% 155 2 CONC S TILE 2X8 RAFTERS @ 24" O.0 245 15 507 245 15 158.4 31.2% Roof Plane 3 4 Roof Type: CONC S TILE CONC S TILE Roof Framing: 2X8 RAFTERS @ 24" O.0 2X8 RAFTERS @ 24" O.0 Roof Azimuth (deg): 155 155 Roof Slope (deg): 15 15 Roof Area (so: 497 275 Array Azimuth (deg): 155 155 Array Tilt (deg): 15 15 Array Area (so: 158.4 70.4 Coverage of Roof 31.9% 25.6% Plane Type: Framing: Azimuth (deg): Slope (deg): Area (so: Azimuth (deg): Tilt (deg): Area (so: veraae of Roof 5 6 CONC S TILE CONC S TILE 2X8 RAFTERS @ 24" O.0 2X8 RAFTERS @ 24" O.0 155 245 15 V 15 713 907 155 245 15 15 140.8 299.2 19.7% 33.0% 7 8 CONC S TILE ROLLED COMP 2x8 RAFTERS @ 24" o.c 2x8 RAFTERS @ 24" o.c 335 0 15 0 438.75 729 335 0 15 0 140.8 176.6 32.1% 24.1% 9 CONC S TILE 2x8 RAFTERS @ 24" o.c U� QUINTA 155 "� i�� 15 �1`I & SAFETY DEPT. 120 g 1LDII�G®\1�� 155 ORCONSTRUCTIO F 17.6 14.7 W W o W Z Q W w LO _ U_ rn W 9 o Z w Q 9 Z Q z LO aLO W n c7 0 g (0 t2 o co 0 N N r i o N � r o a Z 0 0 w PV -2 Roof Plane Roof Type: Roof Framing: (E) ROOF Roof Azimuth (deg): FRAMING, SEE ROOF INFO' Roof Slope (deg): Roof Area (so: Array Azimuth (deg): Array Tilt (deg): Array Area (so: -o % Coverage of Roof 6' Roof Plane Roof Type: o 0, `o, Roof Framing: 1 c' Roof Azimuth (deg): Roof Slope (deg): Roof Area (so: EXT. WALL Array Azimuth (deg): —ARRAY 1 Array Tilt (deg): 9 SOLAR MODULES Array Area (so: 20 ATTACHMENTS % Coverage of Roof a 48" O.C. MAX. 5 6 CONC S TILE CONC S TILE 2X8 RAFTERS @ 24" O.0 2X8 RAFTERS @ 24" O.0 155 245 15 V 15 713 907 155 245 15 15 140.8 299.2 19.7% 33.0% 7 8 CONC S TILE ROLLED COMP 2x8 RAFTERS @ 24" o.c 2x8 RAFTERS @ 24" o.c 335 0 15 0 438.75 729 335 0 15 0 140.8 176.6 32.1% 24.1% 9 CONC S TILE 2x8 RAFTERS @ 24" o.c U� QUINTA 155 "� i�� 15 �1`I & SAFETY DEPT. 120 g 1LDII�G®\1�� 155 ORCONSTRUCTIO F 17.6 14.7 W W o W Z Q W w LO _ U_ rn W 9 o Z w Q 9 Z Q z LO aLO W n c7 0 g (0 t2 o co 0 N N r i o N � r o a Z 0 0 w PV -2 PV MODULES MATCH (E) ROOF SLOPE 2 1/2" ALUMINUM RAIL BY INVISIMOUNT MINI CURB W/ M-1 STRUCTURAL SEALANT TOTAL WEIGHT OF PV MODULES & RAILS: 3297.44 LB TOTAL NUMBER OF ATTACHMENT POINTS: 182 MODULE TYPE, DIMENSIONS & WEIGHT ATTACHMENT DETAIL ROOFS 1-7 & 9 SCALE: 1/2" _ 1'-0" 48.00 INCH TOTAL SURFACE AREA OF PV MODULES: 1302.40 SF DIST. WEIGHT OF PV MODULE ON ROOF (bft 2.53 �1 d E o CSO u�'-� A%y� 6i N Q " dm FASTJACK ATTACHMENTS PANELTYPE: SPR-327-NE-WHT-D a N `" PANEL WEIGHT: 41 LB End Clamp Solar Module o M y 5/16" STAINLESS STEEL LAG BOLT MIN. 2.5" PANEL DIMENSIONS: 61.39 X 41.18 Prosola, �= € TileTrac Attachment,{Lu� INVISIMOUNT . 'r CFVIL o PANEL AREA: 17.60 SF w/ 6 Threaded Stud Railing �,�,/ ' Q a W UNIT WEIGHT OF PANELS: 41/17.6 = 2.33 PSF w o L -Foot '.��`.' INVERTER &RACKING: 0.23 PSF° z = Q - AREA PER ATTACHMENT: 4'X2.76 = 11.04 SF = Concrete Tile/S-Tile ti3 T WEIGHT PER ATTACHMENT: 11.04X2.7 = 29.80 LB Q Roofing Typical o QQ W a PV -2A i� U . Typ. Truss @ 24" O.C. (1)5/16" x 3-1/2" ' SS Lag Bolt w/ 2.5" Min. Penetration ATTACHMENT DETAIL ROOF 8 MOUNTING SYSTEM w PV MODULES MATCH (E) ROOF SLOPE 2 1/2" ALUMINUM RAIL BY INVISIMOUNT MINI CURB W/ M-1 STRUCTURAL SEALANT TOTAL WEIGHT OF PV MODULES & RAILS: 3297.44 LB TOTAL NUMBER OF ATTACHMENT POINTS: 182 WEIGHT PER ATTACHMENT POINT (b/c): 14.57 >, U) O MAX. SPACING BETWEEN ATTACHMENT POINTS: 48.00 INCH TOTAL SURFACE AREA OF PV MODULES: 1302.40 SF DIST. WEIGHT OF PV MODULE ON ROOF (bft 2.53 PSF 2 w W r- o g >, U) O Tw T z zL0 W N ALUMINUM BRACKET x.44 of 'o d ) H w Z u- 0 w Q °' v Q z o CSO u�'-� A%y� 6i N Q FASTJACK ATTACHMENTS W U /�� �+W1W63 N fry QAgOF'E.Qs— W r- o g "L" ALUMINUM BRACKET x.44 of ,n co (E) ROOF FRAMING, SEE ROOF INFO u�'-� A%y� 6i N �O FASTJACK ATTACHMENTS W U /�� �+W1W63 N fry a N `" EXP 5/16" STAINLESS STEEL LAG BOLT MIN. 2.5" PENETRATION SEALED W/ M1 SEALANT 'r CFVIL CAL=M`" w a w o w o z = Q - 0 = Q w Q 0 QQ PV -2A 24.198kW SOLAR ARRAY 74 SUNPOWER 327W MODULES TOTAL STRINGS CONNECTED IN PARALLEL MSP IS SINGLE 400A BUS TO UTILITY GRID BI-DIRECTIONAL UTILITY METER (E) 400 A MAIN SERVICE PANEL 1 PH, 120/240V, 3W LOW MEAN TEMP PER ASHRAE HANDBOOK ROOF -5 WALL -5 (N) MAIN SERVICE DISCONNECT 240V, 350A DERATED 2 -POLE PV BREAKER 240 V, 35 A 2 -POLE PV BREAKER 240 V, 35 A 2 -POLE PV BREAKER 240 V, 30 A 2 -POLE PV BREAKER 240 V, 30 ACD a NOT CENTER 2 -POLE 125A PV BREAKER, c En FED L— � BACKFED BOND TO - ------ GROUNDING CLAMP EXISTING LIFER i ` 6' MIN. -> NEW %"O 81 GROUNDING ELECTRODE U FR VOLTAGE TEMP VOLTAGE LOW TE COEFFICIENT (oC) CORR. (oC) -0.38 1.11 I I I I I I II - II. , II II II II II II II II �I J L HIGH AMBIENT TEMP (oC) CONDUIT HEIGHT R (in) 51 0.5-3.5 51 N/A 6.867kW SOLAR ARRAY (STRINGS 6,7&10) 8 MODULES CONNECTED IN 2 SERIES, 5 MODULES CONNECTED IN 1 SERIES, 1 STRINGS CONNECTED IN PARALLEL @ INVERTER STRING 6 8 MODULES IN SERIES TILT: 15° AZIMUTH: 15 ECDULES IN SERIES STRING 7 TILT: 15° AZIMUTH: 155 DULES IN SERIES STRING 10 TILT: O° AZIMUTH: 0° al i JB S E: N.T.S 5" V 2 ❑ ` ° m 3 OOF TOP ADDED TEMP PER T P JB PEAK POWER TRACKING VOLTAGE: 175-480V @ 4OV Table 310.15(B)(3)@ (oC) CORRE TION 1`'' I 22 73 .50 JB AC NOMINAL VOLTAGE/RANGE: 211-264V @240V SMA America SB6000TL-US-22 (240V) INVERTER I L — € 2 ❑ r I DC VOLTAGE INPUT RANGE: 175-480V @240V '. a E JB STRINGS CONNECTED IN PARALLEL — t4� L MAX AC OUTPUT CURRENT: 25A + O m CEC WEIGHTED EFFICIENCY: 97% . L PANEL DECAL al i JB S E: N.T.S 5" V DC VOLTAGE INPUT RANGE. 175-480 @ ° m 3 OOF TOP ADDED TEMP PER T P ADJUSTED TEMP PEAK POWER TRACKING VOLTAGE: 175-480V @ 4OV Table 310.15(B)(3)@ (oC) CORRE TION 1`'' n E E m 0 2 U 22 73 .50 0 51 AC NOMINAL VOLTAGE/RANGE: 211-264V @240V SMA America SB6000TL-US-22 (240V) INVERTER S € MAX DC VOLTAGE: 600V { i y C n d DC VOLTAGE INPUT RANGE: 175-480V @240V '. a E PEAK POWER TRACKING VOLTAGE: 175-480V @2 V STRINGS CONNECTED IN PARALLEL a AC NOMINAL VOLTAGE/RANGE: 211-264V @240V L MAX AC OUTPUT CURRENT: 25A + O m CEC WEIGHTED EFFICIENCY: 97% o U) PANEL DECAL ; Qj SUNPOWER SPR-327-NE-WHT-D 327W �� '. N C) Vmp= 54.7V Voc= 64.9V` A lJJ Isc= 6.46A Imp= 5.98A AZIMUTH: 155° U CEC PTC POWER=301.4W SMA America SB5000TL-US-22 (240V) INVERTER MAX DC VOLTAGE: 600V ' 240V 6.867kW SOLAR ARRAY DC VOLTAGE INPUT RANGE. 175-480 @ (STRINGS 8&9&11) PEAK POWER TRACKING VOLTAGE: 175-480V @ 4OV 8 MODULES CONNECTED IN 1 SERIES, AC NOMINAL VOLTAGE/RANGE: 211-264V @240V 6 MODULES CONNECTED IN 2 SERIES MAX AC OUTPUT CURRENT: 22A STRINGS CONNECTED IN PARALLEL CEC WEIGHTED EFFICIENCY: 97% @ INVERTER STRING 8 8 MODULES IN SERIES TILT: 15° AZIMUTH: 155° ELECTRICAL EQUIPMENT CALLOUTS ❑A JUNCTION BOX 600 V, NEMA 3R S TIRING 9 , ' 8 MODULES IN SERIES TILT: 15° B 5kW INVERTER UNGROUNDED AZIMUTH: 155° ❑ 1 / STRING 11 SMA AMERICA SB5000TL-US-22 (240V LLQ 5 MODULES IN SERIES TILT: 0° INVERTER 240 VAC, 22 A��L`� E �v�, co p AZIMUTH: O° (WITH INTEG - C DI Oj Cv ts[�/ EP �. N VJ zz �j p� w Lo STRING 1 ❑ �E�C� 24) 'o < rn 6 MODULES IN SERIES TILT: 15° AZIMUTH: 245° S A (W EH INTE �) l o LL1 Q z U z Z w Q u F VVVV ►��'" � o Z Q Z STRING 2 v) Q u, ❑ u 6 MODULES IN SERIES TILT: 15° D SOLA LO ENTE � ❑ LLI '7 a a v AZIMUTH: 245° ONLY D C 240 V OA NEMA 3R, UL LISTED 4 MODULES IN SERIES STRING 3 AC DISCONNECT FUSED W/125A Lo CD TILT: 15° 240 VAC, 200A NEMA 3R, UL LISTED N N Co AZIMUTH: 155° 5.886kW SOLAR ARRAY ❑ N o (STRINGS 1,2&3) a 6 MODULES CONNECTED IN 2 SERIES, 8 MODULES IN SERIES STRING 5 4 MODULES CONNECTED IN 1 SERIES, TILT: 15° STRINGS CONNECTED IN PARALLEL g AZIMUTH: 335° @ INVERTER � STRING 4 5.232kW SOLAR ARRAY a o TILT: 15° (STRINGS 4&5) , 0 z_ ❑ LU AZIMUTH: 245° STRINGS CONNECTED IN PARALLEL ❑ @INVERTER LU Z) -i j U z PV -3 ELECTRICAL NOTES 1. PV ARRAYS ARE PER SINGLE LINE. 2. PV ARRAY WIRING TO JUNCTION IS #10 AWG PV WIRE W/ FIELD INSTALLED MC CONNECTORS TO INTERFACE W/ MODULES. 3. PV ARRAY COMBINER/JUNCTION BOX PROVIDE_ S TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 4. PV POWER SOURCE DISCONNECT (INTEGRATED) RATED AT 36 AMPS, 600Vdc, NEMA 3R RAINPROOF. 5. USE LIFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER N.E.C. 250.58. 6. WHEN REQUIRED, GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM PROTECTION OF BARE ARMOR SHEATHED CABLE FOR ALL CONDUCTOR SIZES. 7. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. 9. INVERTER SHALL BE PER ATTACHED CUT SHEET. 10. AC DISCONNECT SHALL BE PER SINGLE LINE. 11. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO NEC 690. 12. POLE OF PV ARRAY REFERENCED TO GROUND AT THE INVERTER IN SINGLE LINE. 13. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. 14. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% 15. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 16. ALL WORK TO COMPLY WITH 2013 CALIFORNIA ELECTRIC CODE, 2013 CALIFORNIA BUILDING CODE 17. D.C. ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSIBLE COMBINER BOX OR FUSIBLE DC DISCONNECT MEANS. 18. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. 19. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. 20. CONDUCTORS ON ROOF ARE TO BE 1/2" TO 3" OFF OF THE ROOF SURFACE. 21. GEC TO BE CONNECTED TO EXISTING LIFER. iF LIFER IS NOT PRESENT THEN A NEW GROUND ROD WILL BE ADDED FOR GROUNDNG PURPOSES. 22. PV WIRES UTILIZED IN SYSTEM ARE UL -4703 COMPLIANT. 23. ON RESIDENTIAL ROOF INSTALLATIONS ALL RACKING AND MODULES ARE UL2703 COMPLIANT RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/ [INVISIMOUNT INTEGRATED GROUNDING KIT]. MODULES ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES 690.9 (A) MATERIAL LIST 74 SUNPOWER SPR-327-NE-WHT-D MODULE 2 SMA SB5000TL-US-22 (240V) INVERTER 2 SMA SB6000TL-US-22 (240V) INVERTER 164 TILE TRAC ATTACHMENT 18 FAST JACK ATTACHMENT 6216" INVISIMOUNT RAIL 16 SPLICE KIT 84 MIDCLAMP 122 ENDCLAMP 20' 3/4" EMT CONDUIT 115' 3/4" PVC CONDUIT 40' 1 1/4" PVC CONDUIT 1 200A AC DISCONNECT 4 JUNCTION BOX WITH CONNECTORS 1 2 -POLE 125A BREAKER Service Panel Load Calculation MAIN HOUSE Area 6801 sf General Lighting 3 = Small Appliance 2 = Laundry 1 = TOTAL = 3000W @ 100% Total @ 35% _ Range Dryer Load Garbage Disp. Dishwasher Mcrowave Refrigerator Pool pump AC #1 AC #2 AC #3 AC #4 JACuZZI Motor (AC) 25% X4 Net Calculated Load 120/240V, 3 -Wire Service 20.4 kVA 13.602 kVA 6.801 kVA 40.8 kVA 3 kVA 13.2 kVA 16.2 kVA 8 kVA 5.5 kVA 1.5 kVA 1.5 kVA 1-5 kVA 1, 6 kVA 3.84 kVA $ kVA 8 kVA 5.76 kVA 5.76 kVA 5.76 kVA 8 kVA 64.7 kVA 269.7 A ip 05 o3 L 11 (L) o Lu a c E U J U) TOTAL NEW LOAD ON EXISTING 400A SERVICE E W `" W � ❑ Q MAIN HOUSE 269.7 A W MAIN BREAKER (DERATED) 350.0 A OK 0 = W LO w M SOLAR PV SYSTEM 125 A .2 a a d WZ Z 0 w to TOTAL = 394.7 A o Z Q z to BUSBAR RATING = 400 A "' W ^ 5 LO 120% BUSBAR RATING = 480 > 394.7 OK 7 v g C 2 2 -POLE 35A BREAKER Q 0 i 0 04 � o 2 2 -POLE 30A BREAKER CI Q ���� DEPT. ❑ o U') a r -- SAFE SAF 74 GROUNDING CLIP BUILUINO OL 74 GROUND LUG S®U FOR CO ION g W © ® a Z J DATE ------- U) W w PV -3B 1❑. PROVIDE A PLACARD WITH THE FOLLOWING WORDING IN 1" HIGH LETTERING PER NEC 690.17. WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. uTHE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8" HIGH LETTERING, IN ARIAL FONT (NON -BOLD), WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THE FOLLOWING WORDING: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED F3]ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES PROVIDE A SIGN WITH THE FOLLOWING WORDING: WARNING: PHOTOVOLTAIC POWER SOURCE MARKING SHALL BE REFLECTIVE AND PLACED EVERY 10 FEET AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND AT ALL PV COMBINER AND JUNCTION BOXES. PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO -PHOTO PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP -RIVETS OR SCREWS. ANY PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL ALSO HAVE LABEL IDENTIFIED EVERY 10 FEET - AND WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS - WITH A MINIMUM OF 3/8" HIGH WHITE LETTERING ON RED BACKGROUND READING: F5. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER NEC690.35(F) WARNING ELECTRIC SHOCK HAZARD." THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. ISCONNECTL�V "SOLAR AC DISCONNECT." -- � `•f60'Tr N '� Gv zlz 7: PRO E NI _ LABEL AT THE UTILITY INTERACTIVE INVERTER OR GROUND FAULT INDICATOR STATING: WARNING ELECTRICAL SHOCK HAZARD. IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUNDED AND ENERGIZED. J]PLAQUE TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT: ®PER NEC 690.64 AND 705.12(D)(4) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. LABEL DC DISCON LOCATED AT BACKFED BREAKER DEVICES IN UNGR, WARNING CEC690.35(F): INVERTER CONNECTION. DO NOT RELOCATE THIS OVERCURRENT WARP DEVICE. ELECTRIC SHOCK PHOTOVOLT UNGROUNE ENE OR UTILITY OP`ERAT1 TO BE INSTALLED ON THE FACE OF THE =RVICE METER PANEL: CAUTION: OWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN PERMANENTLY AFFIXED PLACARD SHALL BE RIVETED IN PLACE )R CLEAR VISIBILITY INSIDE THE ELECTRICAL PANELS THAT "ATES THE FOLLOWING: THE MAIN SERVICE BREAKER HAS BEEN DOWNSIZED TO 350 AMPS. NO UPSIZING IS PERMITTED LABEL TO BE INSTALLED ON THE INSIDE AND THE OUTSIDE OF THE LOAD CENTER: SOLAR LOAD CENTER: NO ADDITIONAL LOADS ALLOWED 4ECT, JUNCTION BOXES, COMBINER AND )PERATING CURRENT = )UNDED SYSTEMS (TRANSFORMER LESS) PER OPERATING VOLTAGE = 437.6 V 12. LABEL FOR SMA AMERICA SB6000TL-US-22 (240V) ING INVERTER: OAX INVERTER OUTPUT = 1AZARD'THE DC GRID -TIED PHOTOVOLTAIC POWER SOURCE MAX SYSTEM CURRENT = 24.3 A ON THIS OPERATING CURRENT = 17.94 A SYSTEM ARE OPERATING VOLTAGE = 437.6 V AND MAY BE MAX SYSTEM VOLTAGE = 576.31 V IZED. MAX SYSTEM CURRENT = 24.3 A n n MAY INVFR-TFR t7UTA?t]T = .. 6.kW, 25 A, PLAQUE TO BE INSTALLED ON THE FACE OF THE RVICE METER PANEL: CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN AVENIDA FERNANDO I "SOLAR DC DISCONNECT" I L EQUIPMENT ATP - METER AND MAIN SERVICE EQUIPMENT ATp - DC DISCONNECT -INVERTER - AC DISCONNECT CT OF LAQ ouuL niN A'PPF;'Va FOR CONSTRU 12. LABEL FOR SMA AMERICA SB5000TL-� b#4240V ' BY INVERTER: II 3RID-TIED PHOTOVOLTAIC POWER SOURCE )PERATING CURRENT = 17.94 A OPERATING VOLTAGE = 437.6 V OAX SYSTEM VOLTAGE = 576.31 V OAX SYSTEM CURRENT = 24.3 A OAX INVERTER OUTPUT = 6 kW, 25 A, 240VAC 12. LABEL FOR SMA AMERICA SB5000TL-US-22 (240V) INVERTER: GRID -TIED PHOTOVOLTAIC POWER SOURCE OPERATING CURRENT = 17.94 A OPERATING VOLTAGE = 328.2 V MAX SYSTEM VOLTAGE = 432.23 V MAX SYSTEM CURRENT = 24.2 A MAX INVERTER OUTPUT = 5 kW, 22 A, 240VAC 12. LABEL FOR SMA AMERICA SB6000TL-US-22 (240V) INVERTER: GRID -TIED PHOTOVOLTAIC POWER SOURCE INTA DEPT. :D ION W co W W L2 r W Z Q I TF w o N a r 0 N 0 w Z) 0 PV -4 0 0 z a z W LL 0 Z Lu Q Lo r- r - co v co 0 N Lo a cn Lo N N 0) U z c� co OPERATING CURRENT = 17.94 A OPERATING VOLTAGE = 437.6 V MAX SYSTEM VOLTAGE = 576.31 V MAX SYSTEM CURRENT = 24.3 A AC A MAX INVERTER OUTPUT = 6 kW, 25 _ A, INTA DEPT. :D ION W co W W L2 r W Z Q I TF w o N a r 0 N 0 w Z) 0 PV -4 0 0 z a z W LL 0 Z Lu Q Lo r- r - co v co 0 N Lo a cn Lo N N 0) U z c� co 20% EFFICIENCY SunPower E20 panels are the highest efficiency panels on the market today, providing more power in the same amount of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest - efficiency panels with the highest -efficiency inverters, maximizing system output REDUCED Il`ISTALLATIOI`I COST More power per panel means fewer panels per install. This saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique Maxeon'Mcell technology and advanced module design ensure industry-leading reliability MAXEONTM CELL TECHNOLOGY Patented all -back -contact solar cell, providing the industry's highest efficiency and reliability EI - SERIES THE WORLD'S STANDARD FOR SOLAR"' SunPower' E20 Solar Panels provide today's highest efficiency and performance. Powered by SunPower Maxeoni6' cell technology, the E20 series provides panel conversion efficiencies of up to 20.1 %. The E20's low voltage temperature coefficient, anti -reflective glass and exceptional low -light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE SERIES SERIES SERIES MODEL: SPR-327NE-WHT-D ELECTRICAL DATA, Measured at Standard Test Conditions (STCI: irradiance of I OOOW/m=, AM 1.5, and cell temperatum 25' C Peak Power (+5/-3%) Pmax 327 W Cell Efficiency n 22.5% Ponel'Efficiency n 20.1% Rated Voltage Vmpp 54.7 V Rated Current Impp 5.98 A Open Circuit Voltage Voc 64.9 V Short Circuit Current Isc 6.46 A Maximum System Voltage UL 600 V Temperature Coefficients Power (P) -0.38%/K Voltage (Voc) -176.6mV/K currant (lsc) 3.5mA rK NUC 1 45' C +/- 2' C Series Fuse Rating 20 A Grounding Positive grounding not required MM (A) - MOUNTING HOLES (B) - GROUNDING HOLES (IN) 12X 06.6 (.261 IOX 04.2 [.17) I– 1559(61.391 - d 1-V clip'VE MECHANICAL DATA Solar Cells 96 SunPower Maxeon'M cells Front Glass High -transmission tempered glass with anti -reflective (AR) coating JVnctl4n Box IP -65 rated with 3 bypass diodes Dimensions: 32 x 155 x 128 mm Output Cables 1000 mm cables / Mu&Contoct (MC4) connectors Frame Anodized aluminum alloy type 6063 (black) Weight 41.0 lbs (18.6 kg) MM (A) - MOUNTING HOLES (B) - GROUNDING HOLES (IN) 12X 06.6 (.261 IOX 04.2 [.17) I– 1559(61.391 - d 1-V clip'VE 7 ( I OOO wjn- at so' e 1000 w/r,2- 6 a 4 I 3 V 2 500 W/ i 1 0 i Iww/Inr 0 10 20 30 40 50 60 70 Voltage (V) Current/voltage characteristics with dependence on inadionce and module temperature. TESTED OPERATING CONDITION$ Temperature - 40' F to +185' F (- 40' C to + 85' C) Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow) w/specified mounting configurations 50 psf 245 kg/m2 (2400 Pa) front and back (e.g. wind) Impact Resistance Hail: (25 mm) at 51 mph (23 m/s) WARRANTIES AND CERTIFICATIONS Warranties 25 -year limited power warranty 10 -year limited product warranty Certifications Tested to UL 1703. Class C Fire Rating DIMENSIONS 30[1.181 —��- -L– BO1<H ENDS w 12(47) 2i: 11.01.43' —2X577(22.70, 18017.07, _� 1 3^_2112.691 — 4'230.819.091 I I lel — I 1 �. 915;36.021 i 1200[47.241 1535160.451 Please read safety and installation instructions before using this product, visit sunpowercorp.com sunpowercorp.com for more details. 0 2011 SunPower CoWation. SUNPOWER, the SunPower Logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON are trademarks or registered trademarks sunpowercorp.com of SunPower Cog onotion in the US and other countries as well. All Rights Rosormd. Specifications included in this datashoot aro wbieat to chango without notko. Document #001.65484 Re,'B / LTR EN C U` us C511_316 ............................ Efficiency curve SUNNY BOY 5000TL-US-22 240Vac!------------------ _----- '.. Sunny Boy 30007E -US Boy Sunny 380OTL-US Y Sunny Boy 400url.-US - Technical data - - 0/0 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 2.40 V AC Input (DC) L1L] 741, UL 1998, UL 169913, IEEE 154/, FI -L- Fort 13 (L-latt A 6 6), CAI I/ C3A C22.2 107. 1-1 SB 5000TL.US-22 Man, usable Dr: Power (3) co, Ip - 1) - _- . _ _. 3200 W 4200 W _ _ 420U W Max. DC voltage 600 V 600 V 600 V Ruled MPPT_.ullage range- _ 175 - 480Y_ _ 175 - 480 V 175 - 480 V MPPT operating voltage rnnge _: - - 125 - 500 V 125 - 500 V - 125 - 300 V Min. DC voltage / start voltage_ 125 V/ 150 V 125 V/ 150 V 1_25 V/ 150 V Max. operating input current / per MPP tracker 18 A / 15 A 24 A / 1-5 A 24A/ 15A Number of MPP trackers / strings per MPP tracker SW 2/2 O. .put (AC) AC nominal power 3006 W 3330 W 3846W 4000 W I&A. AC pvwent pa•xar 3000 YA 3330 VA 3840 VA 4000 VA NI, ;,,,I AC valtago / edjuatably 208 V1_ -f _240 V / • 208 V / • 240 V./ • 2089 / 0 - 240 V / • AC voltage range 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V AC y.id L�yv r, r�i;g6 _ 60_1-17 / 59.3 -_ 60.5 Hz - _ , ,- 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz Max. output current 15 A 16 A 20A faet8r (eas Output phases / line connections 1 / 2 1 /2 1 / 9 Harmonics < 4% <4% < A Efficiency Max-efficienry 97.2% 97.6% 97.2% 97.5% 97.2% 97.5% CEC vfficionry _96.5% 96.5% - 96.5% 97.0% 96.5% 97.0% Prntertinn devices _ 90 DI_ LI!tL;...nn. n ....1.0 . • DC.o.o.,c-polarit/prataelion 4000T0TL-US-22 O-0 r-1 Ind fnult mnnitnrina / Grid monitorina _ 4/4 V-1 V Af r6nrt ri-it prntartinn - _ _ -_ _ -- - - - - • All -pole sensitive residuul current monitoring unit FA 0 Arc fault circuit interrupter (AFCI) compliant to UL 16998 08 EbN + Protection class / QY@ryoltape category I / IV Coneral date EtaN.75 �_Ah ' Dhneusluns (Ye / I I /D) h....... (6.1 490 / .519 / 185 (19.3 / 26.5 / 7.3) _ DC Disconnect dimensions (W / H / D) in mm (in) • Standard feature O Optional feature - Noi available 187 / 297 / 190 (7.4 / 11.7 / 7.5) Data at nominal conditions Packing dimensions (W / H / D) in mm (in) Sunuy Buj 5000TL•US 617 / 597 / 266 (24.3 / 23.5 / 10.5) Sunny Boy 7000TL-US uL utteonneci packing dlmenslu.o (W / I I / D) i....na (i.;) 208 V AC 240 V AC 370 / 940 / 280 (14.4 / 9.4 /_1 1.0)__ 208 V AC 240 V AC Weight / DC Disconnect weight 53001.41 24 kg (53 Ib) / 3.5 kg (8 Ib) - - - 7300 W Packing weight / DC Disconnect packing weight 600'1 27 kg 160 Ib) / 3.5 kg (8 Ib) 600 V Operating temperature range 175 - 480 V -40 *C... +60 'C (-40 *F... +140 'F) 245 - 480 V Noise emission (typical) 5 25 dB(A) < 25 dB(A) < 25 dB(A) Internal consumption at night < 1 W < 1 W < 1 W Topology Transformerless Transformerless Transformerless Cooling Convection Convection Convection Electronics protection rating NEMA 311 NEMA 3R NEMA 3R Features 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA t,atura ve,Lnn WWI • • • Ilizldny 0rriphie. • • - • Interfaces- RS4R.5 / Speedwire/Webconnect 0/0 0/0 0/0 Warranty: 10 / 15/ 20 years 0/,U/,u •,0/e • /t i /n Lertd.cates Mid p8rmltt (more uvulluble un .eyuesl) UL 1741, L IL 19011, 111 IAVVR, IFFF 1 5d/ n,L, ren I (Class.A tk Bl, CAIJIrCSA C22.2 107.1 1 NOTE: US inverters ship with gray lids 1/2 <4% <4% Type designation SB 3000TL-US-22 SB 380OTL-US-22 SB 4000TL-US-22 ............................ Efficiency curve SUNNY BOY 5000TL-US-22 240Vac!------------------ _----- '.. Accessories -. 99 a/n L,i 0/0 0/0 •/0/O 6/0/0 6/0/0 Spee&ire/W ebconned RS485 interface L1L] 741, UL 1998, UL 169913, IEEE 154/, FI -L- Fort 13 (L-latt A 6 6), CAI I/ C3A C22.2 107. 1-1 SB 5000TL.US-22 SB 6000TL.US-22 SB 7000TL-UC22 SB 770OTL-US-22 ' • • . ••••••••L interlace D M-485C8-US 96. �-- .. ................ SW 94..�. 90 4000T0TL-US-22 O-0 V-1 V _ _ FA 08 EbN EtaN.75 �_Ah ' 0.0 0.2 6.4 0.6 U.8 ..0 • Standard feature O Optional feature - Noi available Rated power ________Output power.. Rated power ______________________________ _ Data at nominal conditions Sunuy Buj 5000TL•US Sunny Roy 600071.41S Sunny Boy 7000TL-US - - Sunny Boy 770OTL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 53001.41 - 63M W y - - - 7300 W 8000 W 600'1 - - ..600 V 600 V - - 600 V 175 - 480 V 210 - 480-9 245 - 480 V 276 - 480 V 125 - 500 v 125 500V „ - 125 - 500,Y __. _ 125 - 500V 125V/ 150V _125V/ 150V _ 125V/ 150V 125V/ 150V _3OA/ 15A 30A/ 15-A 30 A/ 18A 3OA/ 18A _ 2/2 4550 W 5000 w 51M W 6nnn W 6000 W 7000 W 6650 W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208 V /' 240 V / • 208 V/ • 240 V/ Is 208 V/ • 240 V / • 208 V / • 240 V / • - 183 - 229 V 211 - 264 V 183 270 V 91 1 - ?Ad V 183 - 229 Y_ - 21 1 - 264 V 183 - 229 V 211 __264 V 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59,3 - 60.5 Hz 60 Hz / 59.3 -- 60.5 Hz 22 A 25A 29.2 A 32A -- IrL 1/7 1/2 1/2 <4% <4% 147, r49b - 97.2% 96.5 < 29 dB(A) <1 W Transformerless Convection NEMA 311 97.6% 97.0% 97.0% 96,5 97.4% 96.8% 97.0% 96.5% • / IV nvu i � 1 v_r' i r)J_f 1.9,3 i I4s r % 51 197,1 2o7,/ 1 Qn (7 4 / 1 1 7,/ 7 5) 617 / 597 / 266 (24.3 / 23.5 / 10.5) 370/240/280 (14.6/9.4/11.0) 24 ky (6316); 3,51rg L8 Ib) 27 kg (60 16) / 3.5 kg (8 Ib) -AO 'C...+60'C (-40'F...+140'F) < 29 dB(A) < 29 dB(A) < 1 W < 1 W Transformerless Transformerless Fan Fan NEMA 3R NEMA 3R 96.8% 96.8% 97.3% 96.5% 96.5% 96.5% < 29 dB(A) <I W Transformerless Fan NEMA 3R a/n L,i 0/0 0/0 •/0/O 6/0/0 6/0/0 •%U%U L1L] 741, UL 1998, UL 169913, IEEE 154/, FI -L- Fort 13 (L-latt A 6 6), CAI I/ C3A C22.2 107. 1-1 SB 5000TL.US-22 SB 6000TL.US-22 SB 7000TL-UC22 SB 770OTL-US-22 ,a _ . z r v1• � �r -fry a, F. ' ti RS-111WIT"701nvisiMoun T Residential Mounting System Simple and Fast Installation Integrated i -nodule -to -rail grounding Pre -assembled mid and end clamps Levitating mid clamp for easy placernent Mid clamp width facilitates consistent, even module spacing Simple, pre -drilled rail splice UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer -Preferred Aesthetics #1 module and #1 mounting aesthetics Best -in -class system aesthetics Premium, low -profile design Black anodized components Hidden raid clarrips and end clamps and capped, flush rails Part of Superior System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics Combine with SunPower modules and monitoring app ri / / :r a, G •r � Elegant Simplicity SunPower'' InvisiMount"I" is a SunPower-designed rail -based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system -level approach will amplify the aesthetic and installation benefits for both homeowners and installers. sunpower.com uL -5 UNP IRE a D. ~ . w N r -- _<&Maii4e SunPowerR InuMoun TM Re�sident�ial Mounting System Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap i �cA WLi;�!k !'X wf* -4.7r ofaW' mi ? t©) If,`1lUCp]�rfft CCc�n 7 i c i^Y�fi^Yi �t•�l)L'+•i Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized alurninum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 Wrn (9 oz/ft) Rail Splice Aluminurn alloy 6005 -TS 830 g/rn (9 cz/fq Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug) 106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) �cA WLi;�!k !'X wf* -4.7r ofaW' mi ? t©) Temperature —40° C to 90' C (-4(1° F to 194' F) Composition Shingle Rafter Attachment 3000 Pa upiift. 6000 Pa downforce Composition Shingle Roof Dec%mg Attachment Application Cunied and Flat Tae Roof Attachment UL 2703 Listed Universal Interface for Other Roof Attachments ,YIiN{�k]L.ff ')XxrX,do fr % Ce Ctl 111�%ff i Temperature —40° C to 90' C (-4(1° F to 194' F) Max. Load (LRFD) 3000 Pa upiift. 6000 Pa downforce n+030%,"'v W;cdift M;c C 'iiC tP"LoXI.� 25 -year product warranty Warranties S /ear tinish warranty UL 2703 Listed Certifications Class A Fire Rated Refer to roof attachment hardware manufacturer's documentation. *Module frame that is compatible with the InvisiMount system required for hardware interoperability. C 2015 SunPower co! poration. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks- of SunPower corporation. All other trademark!; are the property of their respective owners. SUnpovver.Com Specrfications included in this datarheet are subject to chane without notice. Document #509506 RevC t� 1 D D f 7 .v t .r^ Third Par d Lab Testealloa 4500 lbs Side � load 100 lbs o f?Tested j' Vpa rP professional It ^b produ'TcAin`. NEWMA (805) 4'86-4■700 (805) 486-4799—fax 1551 S. Rose Ave. Oxnard, CA 93033 View more infoon our website at: w olar.com T�l / eTIrd C Patent #5,146,029 • Tile Roof Structural Attachment NEW STAINLESS STEEL TILE FLASHING The patented TileTrac© attachment allows for a structural roof rafter connection with optimal attachment stud location adiustability. Design results in the best looking systems in the industry. TileTrac ° for s -curve Tile Trac ° for flat concrete tile concrete tile (6" Tall Threaded Stud) kl,(4" Tall Threaded Stud) Part # TT -18-T6 Part # TT -18-T4 Benefits of TileTrac° • Easiest and lowest cost waterproof tile roof • Includes Stainless Steel tile flashing and attachment Stainless Steel lag bolt • Over 15 years of industry preferred single lag • Aluminum and Stainless Steel components for bolt design maximum corrosion resistance and strength • 3rd party lab waterproof and load tested • Large roof surface contact area evenly • Compression sealed at underlayment and top distributes load of the The TileTrac® Design Structurally attaches to roof rafter and allows the rail attachment stud to be located at the strongest point of the the (the crown) where water does not flow. High Point/ Without TileTrac® With Ti eTrac° Water Flows Crown Sealed at top of tile in the Valley of the Tile -L of the Tile (optimum) 0 /"—. :y L Rail swold"m— TAM TileTrac® assembly / Sealed at structurally Not structurally underlayment Rafter attached to Rafter attached to the rafter the rafter Installation steps for both s -curve and flat concrete tile* STEP 1: Select a file in the area of the roof rafter Step 4: Seal the initial tile nail hole. Using a 3/16" drill bit and drill guide (FJ -Drill), drill pilot hole along the rafter center Step 7. After bolting the base to the roof, slide the upper carriage into the correct position under the crown of the tile. For Flat tile, slide the upper carriage near the middle of the tile. STEP 2: Remove the file by pushing and pulling. It is usually held in place by a small nail. Step 5: Insert the lag bolt and washer through the TileTrac° and apply fresh compatible sealant to the base. W Step 8: Replace the file by lining up the snap lines and mark the drill location accordingly. Step 10: Insert threaded stud through file and hand -tighten to engage with base. Bind two 3/8" nuts (included) using 9/16" wrenches and tighten. 'Not recommended for clay or slate tiles. Step 11: Unbind nuts and remove from stud. Apply sealant around stud at file opening and compress with Stainless Steel flashing (included) until seated. STEP 3: Using an electronic stud finder (recommended), or other means, locate the rafter center. Mark a reference point on the file above. Step 6: Using a 1/2" socket, install the lag bolt until seated. Do not overlighten. The sealant should flow outward sealing any holes. II \ _ P Use -o Rota Hammer drill for a 5 secaq drill time. Step 9: Using a 1/2" carbide drill bit and ROTARY HAMMER DRILL in hammer mode, drill through the tile. See online video at www.prosolar.com for details. Step 12: Fasten rail with lower and upper 3/8" nuts/washers as shown. ©Professional Solar Products, Inc. Mar. 2011. TileTrac is a registered trademark and covered under Pat. #5,746,029 CAUTION POWER TO THIS BUILDING IS ALSO -SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: AVENIDA FERNANDO FRONT OF HOME (N)SOLAR ARRAY YOU ARE HERE SERVICE POINT & UTILITY METERING 48775 AVENIDA FERNANDO , LA QUINTA 92253 - (N) PV INVERTERS - (N) SOLAR LOAD CENTER (N) AC DISCONNECT % UIi TA I SAF ETY DEPT �� •� � � -j CONS E � TRUCTION ✓� BY