Loading...
0104-035 (SFD) Title 24Carole Christensen, Certified Energy Analyst TITLE -24 ENERGY CALCULATIONS ENERGY CALCULATIONS FOR: Andrzej Weber, Architect, AIA 74433 El Paseo, Suite A Palm Desert, CA 92260 May 7, 2001 PROJECT: Utah Lindell Residence 4210 sq.ft. Custom Home 55-710 Cherry Hills, PGA West La Qainta, CA 92253 Standard Design Proposed Design Compliance Margin 52..40 50.35 +2.05 CTZ 15 - 32.7% fenestration 411VAC Zones—Zonal Control Metal fenestration - Milgard or better, Std. Drape Lt Blinds on Bedrooms, Laundry and Hall Walls R-19; Roof R-38, Duct R.4.2; AFUE 80%, SEER 12.0 One 100 gal gas water heater, RecircTimetemp CONTENTS CF -1R MF -1R C -2R C -3R HVAC Sizing S6-110 UI I -Y QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE Slit I dl BY 47-5"LaW Cmyon Dirft Aguw a- C.! 92536 1-800-735-8152 Afew&r CABEC . Ca4 *"m AriocPMM of Bw1d*g fwv Cox-ftnu s=f CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Utah Lindell Residence Date..05/07/01 13:20:32 Pxo'ect Address 55-710 Ch H'll ******* PGAW, La Quinta, CA *v5.10* Documentation Author... Carole Christensen Building Permit Carole Christensen. 4.7-596 Lake Canyon Drive PlanCheck,/ ate Aguanga., CA 92536 800-735-815.2 - ie C ec Date Climate ,Zone. ..... 15 Compliance Method...... MICROPAS5 V5.10 for 1998 Standards by Enercomp, Inc. MICROPASS v5.10 File -UTAH Wth-CTZiSS92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run-Drpl2.80R19.30.4.1 100Rec GENERAL INFORMATION Conditioned Floor Area..... 'Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units.... Number of Stories.. ....... Floor Construction Type.... Glazing Percentage......... Average Glazing U -value.... Average Glazing SHGC:...... Average Ceiling Height..... 4210 sf Single Family Detached New Front Facing 209 deg (SW) 1 1 Slab On Grade 32.7 k of floor area 0.7 Btu/hr-sf-F 0.69 11.1 ft BUILDING SHELL INSULATION Component Frame. Cavity Sheathing Total Assembly Type Type R -value R=value R -value U -value Location/Comments Wall, Wood R-17.8 R-0 R-17.8 0.0.65 Wall Wood R-17.8 R-0 R-17.8 0.064 To mech, To.garage to mech Roof Wood R-11 R-27 R-38 0.025 attic, Attic S1abEdge None R-0 R-0 F2=0.760 To Outside S1abEdge None R-0 R-0 F2=0.5'10 To garage, to garage g Td gar/mach, To mech Door None R-0 R-0 R-0 0..330 solid wood Wall wood R-0 R-0 R-0 0.386 FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (sf) Value SHGC Shading Shading Fins Window Front (SW) 30.0 0.620 0.710 Standard BldShade None Window Front (SW) 57.0 0.620 0.710 Blind BldShade None Door Left (NW) 64.0 0.740 0.690 Standard BldShade None Door Left (NW) 72.0 0.740 0.690 Blind BldShade None Window Left (N) 25.0 0.570 0.670 Standard BldShade. None Window Back (NE) 15.0 0.570 0.670 Standard BldShade None Window Right (SE) 42.0 0.740 0.680 Standard Standard Yes Window Right (SE) 12.0 0.740 0.680 Standard Standard None Window Right (S) 17.5 0.62.0 0.710 Blind Standard Yes Window Front (SW) 32.5 0.620 0:710 Standard BldShade None Door Front (SW) 93.0 0.740 0.690 Standard BldShade None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Utah Lindell Residence Date..05/07/01 13:2.0:32 MICROPASS v5.10 File -UTAH Wth-CTZ15S92 Program -FORM CF -1R . User#-MP10.17 User -Carole Christensen Run-Drpl2.80R19.30.4.1 100Rec FENESTRATION f Area U- Interior Exterior Over - hang/ Orientation (sf) Value SHGC Shading Shading Fins window Front (SW) 39.0- 0.620 0.710 Standard Standard None Door Front (SW) 4.8.0 0.550 0:650 Standard Standard None Window Front (Sw) 14.0 0.620 0.710 Standard Standard None Door Right (S) 56.0 0.740 0.690 Standard Standard None Window Front (W) 31.5 0.620 0.710 Standard Standard None Window Left (NW) 9.8 0.620 0.710 Standard B1dShade None Window Left (N) 5.5 0.740 0.680 Blind Standard None Window Left (N) 18.0 0.740 0.680 Blind Standard Yes Window Left (NW) 18.0 0.740 0.680 Blind Standard Yes Door Left (N) 64.0 0.740 0.690 Blind Standard Yes window Back (NE) 20.0 0.740 0.680 Standard Standard None Window Back (NE) 4.2.0 0.740 0.680 Standard Standard Yes window Back (E) 21.0 0.620 0.710 Standard Standard Yes Window Right (SE) 38.5 0.620 0.710 Standard B1dShade None Door Back (NE) 108.0 0.740 0.690 Standard Standard None Window Back. (NE) 3.9.0 0.620 0.710 Standard Standard None Skylight Hor.z 9.0 0:940 0.730 None None None Door Right (S) 64.0 0.74.0 0.690 Blind B1dShade None Door Right (S) 64.0 0.74.0 0.690 Blind B1dShade None Window Right (S) 20.0 0..74.0 0.680 Standard B1dShade. None Window Right (S) 6.0 0.740 0.680 Standard B1dShade None window Front. (W) 6.0 0.740 0.680 Standard B1dShade None Window Back (.E) 15.0 0.740 6.680 Standard BZdShade None Window Front. (W) 30.0 0.740 0.680 Blind B1dShade None Door Left (NW) 64.0 0.740 0.690 Blind B1dShade None Window Left (N) 32.0, 0.6.20 0.710 Blind Standard Yes window Right (SE) 9.0 0.740 0.68.0 Blind Standard None Window Right (SE) 24.0 0.570 0.670 Standard Standard Yes SLAB SURFACES Area Slab Type (sf) Standard Slab 986 Standard Slab 790 Standard Slab 468 THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments InteriorHorz Yes 125 1.0 cabinet tops S1abOnGrade Yes 970 3.5 Tile S1abOnGrade No 996 3.5 Carpet CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Utah Lindell. Residence Date..05/07/01 13:20:32 MICROPASS v5..10 File -UTAH Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run-Drpl2.8'0R19.30.4.1 10ORec HVAC SYSTEMS System ,Large WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Lose Insulation Efficiency Input Fraction R -value 0.909 n/a 0.012.6 R-n/a Pilot Light 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** ** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Zonally Controlled HVAC System. This building incorporates non-standard Fenestration Shading. This building incorporates a High Mass Design.. This building incorporates non-standard Water Heating System REMARKS Zone 1 —Master Suite Zone 2 - Living Area Zone 3 - Guest bedrooms Zone 4 - Casitas Milgard fenestration or better Minimum Duct Duct Tested Duct ACOA Thermostat Equipment Type Efficiency Location R -value Leakage Manual D Type Furnace 0.800 AFUE Attic R-4.2 No No SleepingS ACSplit 12.00 SEER Attic R-4.2 No No SleepingS Furnace 0.800 AFIIE Attic R-4.2 No No LivingSta ACSplit 12.00 SEER Attic R-4.2 No No LivingSta Furnace 0.800 AFUE Attic R-4.2 No No SleepingS ACSplit 12.00 SEER Attic R-4.2 No No SleepingS Furnace 0.800 AFUE Attic R-4.2 No No SleepingS ACSplit 3.2.00 SEER Attic R-4.2 No No SleepingS WATER HEATING SYSTEMS Number Tank. External in Energy Size Insulation Tank;Type Heater Type Distribution Type System Factor (gal) R -value Large Gas Recirc/TimeTemp 1 n/a 100 R-0 System ,Large WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Lose Insulation Efficiency Input Fraction R -value 0.909 n/a 0.012.6 R-n/a Pilot Light 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** ** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Zonally Controlled HVAC System. This building incorporates non-standard Fenestration Shading. This building incorporates a High Mass Design.. This building incorporates non-standard Water Heating System REMARKS Zone 1 —Master Suite Zone 2 - Living Area Zone 3 - Guest bedrooms Zone 4 - Casitas Milgard fenestration or better CERTIFICATE OF COMPLIANCE; RESIDENTIAL Page 4 CF -1R Project Title.......... Utah Lindell Residence Date. .05/07,/0.1 13:20:32 MICROPASS x5.10 File -UTAH Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4.1 100Rec REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a -single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section.. DESIGNER or OWNER Name.... Andrzej J. Weber, AIA Name.... Company. Architect Company. Address. 74-133 El Paseo, Ste A Address. Palm Desert, Ca 92260 Phone... (760) 340-300 Phone... License. Signed.. igned.. t ENFORCEMENT AGENCY Name.... Title.... Agency., Phone... DOCUMENTATION AUTHOR. Carole Christensen Carole Christensen 47-596 Lake Canyon Drive Aguanga, CA 92536 800-735-8152 IWA -f-7-0 ePtlfled KA®Pgir Analy Carole Christensen, r r A 98H Signed C A $ E C ate cafomia A wdmam d DuudIA9 Enmgy MANDATORY MEASURES, CHECKLIST: RESIDENTIAL (Page i ore) MF -IR Note: Lowtise residential buildings subjoct to the Standardf man contain titter measures rept ess of the compliance approach used. Items marked with an asterisk (' may be wpasoded by *note svh4jeat eomplianoe regttirenwnts listed on t aZertiticate of Compliance. When this eheddist is incorporated into the perntitdoeunents, die features Doted shall, be considered by all parties as miniumm cornponettt petfommnce speeifieWons, for *ho- mandatory nnearza whodw tbt y ate shown dwwbato in the documents or on this checklist only. Instructions: Check or initial.applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Bulidlag Envelope Measures: Minimum R-19 ceiling insulation. ✓ 6150(b): Loose fiN imuMon nrartufaeum's bbeled R -Value. Ar/4 ` USNO Minimum R-13 wan insulation in wood footed wallt or equivalent U-Fsetot in metal ftame walls / doer net WAY to exterior mate walls). v 1150(4): Minimum R-13 seised Floor insulatim in hated floors. i 15W): Slab edge hwAztico - water absorption Ree tw gmator than 0.3%. valor vapor transmission rase ✓ no Rmter deet 2.0 perrolinch. f 1 its: bu uWoa specified er instilled meas insulation.quoRy aandard< indicate type and fbrgt. WOO*' 1116-17: Feocomim Produces. txurkw Doan. and lofldtratioa/Eafiluslica C awls 1. Dopa and windows bexw ou conditioned and uneendidooed spaces desipned to funis air leakage. 2. Fenestration pioduers (except field -fabricated) have label with eetiSed U-P=or, Certified Sour Meet Gain Coefficient (SHOC:), and infiltration certification: 3. Exorsior,doms and windows wombastrippe& 311.Wots.and penetrations caulked sad sealed ✓ JISO(& Vapor baniert mandatory in Climate Zones 14 and 16 only. A* Mo. f iSo(f1 Speeiat inRlcatiowbanier Wattled to eornply with f IS l wrest Commission quality standards §150(4 U►stallation of Finplaca. Ddxtatrve Ons Appliance and Gat LAes. I..Masons)r and Sctory'built farWlaaa baM a. Cksablo mewl or gloss door b. Outside air intake with damps: and control c. F)te damper and Control 2.,No rontimtoas burning gas pilot lights a(lowed. Space Conditioning, Waw Heating And .Plumbing System Measures: 11 104111. HVAC equipment, wataheaurs, slwwabeads and hoc ea exrtified by the Coomistao1l. ✓ 4130): Heating wWkw tacit g loads edlmbeed in a000tdanee with ASNRAP DAACMA a ACOA 613o(ik Setback thermostat on &)) applicable Mating and/or cooling sysmms_, i 1 SOnj . Pipe and rank insulation 1. StorApSu walea'heaters rated widtan Enctgy Faegor lessthan 0-59 must be externally wrapped with insonation having t►p **led thermal resistance of R-12 or grater. 2. Piet S feet of rept; elastin to water beam tank, non-redirculating systems. insulated (R-4 or grata) 3. Bacl;49 tanks fa soW symem- emfirod swage tanks, or odea inditeot.hot wokr Conks have R-12 eatenal ieseWion or R=16 oaabined.inoanaUamansl:insubtioo 4. All bwied or exposed piping-inwlaeed in taeirculaeing kerions of ha water systems. S. Cootiag system piping below SS• F insulseed. 6. -Piping insulated betweso beadeg source and indirect hot water rands. ✓ January 4, 2001. MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) ff -YR. Note: Lowtiye residential buildings &Men to-deStaatlards nttsat,contaitt tht sc trtesattres rcpudless,of the compliance approach used. Item manned with an somisk (0) may brsuperecded by.atom.sttingent compliance requirements listed on the CertiBcato of Compliance. When this cbeddist is incorporated imo the pamit dwxnmts, the featenu noted shall be considered by all parties as minimum component per% n om sped6cations for.the mandatory measures wbedw they an shown elsewbem in the documents or on this checklist only. Instructions: Check or initial applicable boxes when compleW or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Spate Conditioning, Water Headag and Plugs System Measures: (eondatted) 415%%): Dnotsand.Faas J. All ducts and piaseaMA salodand insulated to meet the rogeironatt ofthe 1998 CMC Sections 601.603:604, and StaMetd 63: dtteee insob►tad to a tninntnao'oetttlkd bral.of R�1 orettt' I' l l endrdy in conditioned gMca OpenivP shall be sealed with Moot, tape, atsthaelit int. or other dot wit su e syateealbameasthea�pliabferegoitee mins afM 181, UL 181A, or UL 18113. Iftmsoc or I" is used b scot opm&uW Vcaser than iN ln* the eombbadw of mastic and aWbw mob or tape Shan be used_ Buildnhg avniea sbap not be teed:Careonveying oordiriotted air, ]nine and aeama otduet systettts and dhdr acmpenents shau not be waled with doth back robber adhesive doer repo unless such ape is used in eombination with mastic and dumbnAL 2.1?xhust fan systems have back dmik at atomic dampers.. 3. Gravity vandla ft systems serving one Boned space have either suWaslic or readily accessible, m wWl ted §114: pool and'Spa ltearittg Systesnsand Equipment. 1. Sysum is eew&wd with 7wthenaai dr imcy: o"ff switch, weadnetproofopaatiag instruwans. no electric resistance heating ctrl no -pilot li8ltt I Syatmn is inm1w widr. a. At teas06" cf pipe betuisen filter and heater for fano scar iMftp. b. Cover for outdoor pools or outdoor span, 9. pool system has dimcdonal ialots and a eiteuiatien pt®p omeswitch. § I 15: Gas fund cumin [emcees. Pool booms, spa heaters or haauadtotd cooking appliaAM have no 1 eon ' s tine: Ndn4ieeaiesl' floes aim InIct < ISO Bta/ht a� Ughtine Measures: I1SO(k)1s Lm asires he rwal lighting in khdum dull have ,.Imp with an efficacy of 40 hung alwall or geasuz for general lighting is kitahaas. Wo 8annd U*Ang shall be cenuolled by a switch on a teadily soasible lighting ooanotPad at an mtranos,to the kitdtm. d,1SNk)2: Room with a shower or bathtub ehmt have either at kart one hunbtaire with Imps with an efficacy of 4o to nwafwatr or pester switched at the coMm w dto room ar one of the aldtnstira to this . Mahn allowed is 1 aad:rxeaed emir fbmum ue C insuietioa cover January 4, 2001 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title .......... Utah Lindell Residence. Date..05/07/01 13:20:32 ******* Project Address........ 55-7.10 Cherry Hills PGAW, La Quinta, CA *x5.10* Documentation Author... Carole Christensen ******* Building Permit Carole Christensen 47-59.6 Lake Canyon Drive Plan ec Dat Aguanga., CA 92536 800-735-8152 Field Che -c Dat Climate Zone.. ..... 15 Compliance Method...... MICROPAS5 x5.10 for 1998 Standards by Enercomp,, Inc. MICRO.PAS5 v5..10 File -UTAH Wth-CTZ15S92 Program-FORM_C-2R User#-MP1017 User -Carole Christensen Run-Drp12.,80R19.30.4.1 100Rec MICROPAS5 ENERGY USE SUMMARY (s£) Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating,....... 4.02 5.07 -1.05 Space Cooling.......... 41.61 39.73 1.88 Water Heating....., . 6.77 5.55 1.22 Total 52.40 50.35 2.05 *** Building complies with Computer Performance *** GENERAL.INFORMATION Conditioned Floor Area..... 4210 sf Building Type. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 209 deg (SW) Number of Dwelling Units... 1 Numberof Building Stories. 1 Weather Data Type........,. ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage. ....... Average Glazing U -value.... Average Glazing SHGC....... Average Ceiling Height..... Floor 3ZONE Slab On. Grade 4 46811 cf 4210 sf 32.7 4rof floor area 0.7 Btu/hr-sf-F 0.69 11.1 ,f t BUILDING ZONE INFORMATION # of Vent Vent Air Volume Dwell Cond- Thermostat Height Area Leakage (cf) Units itioned Type (ft) (sf) Credit 936.9 0.00 Yes SleepingStat 2.0 Standard No 24969 1.00 Yes LivingStat 2.0 Standard No Area Zone Type (s£) 1ZONE Sleeping 986 2ZONE Living 1966 3ZONE Slab On. Grade 4 46811 cf 4210 sf 32.7 4rof floor area 0.7 Btu/hr-sf-F 0.69 11.1 ,f t BUILDING ZONE INFORMATION # of Vent Vent Air Volume Dwell Cond- Thermostat Height Area Leakage (cf) Units itioned Type (ft) (sf) Credit 936.9 0.00 Yes SleepingStat 2.0 Standard No 24969 1.00 Yes LivingStat 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title..,....... Utah Lindell Residence. Date.. .05/07/01 23:20:32 MICROPAS5 v5.10 File -UTAH Wth-CTZ15S92 Program-FORM.C-2R User#-MP1017 User -Carole Christensen Run-Drp1.2.80R19.3.0.4.1 100Rec Zone Type :Sleeping 4'ZONE .Sleeping Surface 'BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- Thermostat (sf) (Cf) Units itioned Type. 790 7896 0.00 Yes SleepingStat 468 Area (sf) Vent vent Air Height Area Leakage (ft) (sf) Credit 2..0 Standard No 4577 0.00 Yes SleepingStat 2.0 Standard No OPAQUE SURFACES' U= Insul Act Solar Form 3 Location/ value R-val Azm Tilt Gains Reference Comments 1ZONE 1 Wall 43 0.06.5 17.8 209 90 No W.19.2X6.16 2 Wall 154 0.065 17.8 2.99 90 No W -19.2X6.1.6 3 Wall 75 0.065 17.8 344 90iN0 W..19.2X6.16 4 Wall 39 0.065 17.8 29 90 No W.19.2X6.16 5 Wall 4.16 0.065 .17.8 119 .90 Yes W_.19.2X6.16 6 Wall. 33 0.065 17.8 164 90 Yes W.19.2X6.16 '7 Wall 180 0.064 17.8 209 90 No GWALL.R19 To mech 8 Roof 986 0.025 38 n/a 0 Yes R.38.2X4.24A attic 2ZONE 11 Wall 40 0.065 17.8 299 90 No W..19.2X6.16 12 Wall 37 0.065 17.8 209 90 No W..19.2X6.16 13 Wall 42 0.065 17.8 209 90'Yes W..19.2X6.1.6 14 Wall 24 0.065 17.8 164 90 Yes W.19.2X6.1.6 15 Wall 37 0.065 17.8 254 9.0 Yes W.19.2X6.16 16 Wall 568 0.065 17.8 344 90 Yes W.19.2X6.16 17 Wall 113 0.0.65 17.8 299 90 Yes W.19.2X6.16 18 Wall 360 0.065 17.8 29 90 Yes W.19.2X6.16 1.9 Wall 15 0.065 17.8 74 90 Yes W.19.2X6.16 20 Wall 92 0..065 17.8 119 90 -No W.19.2X6.1.6 21 Wall 89 0.065 17.8 209 90 Yes W.19.2X6.16 22 Wall 171 0.064 17.8 209 9.0 No GWALL.R19 To garage 23 Door 24 0.330 0 209 90 No None solid wood 24 Roof 1471 0.025 38 n/a 0 Yes R.38.2X4.24A Attic 3ZONE 27 Wall 2.96 0.065 17.8 164 90 No W.19.2X6.16 28 Wall 17 0.065 17.8 254 9.0 No 'W.19.2X6.16 29 Wall 53 0.065 17.8 74 90 No W.19.2X6.16 30 Wall 15.5 0.064 17.8 209 90 No GWALL.R19.To garage 3',1 Roof 790 0.025 38 n/a 0 Yes R.18.2X4.2A attic OZONE 34 Wall 72 0.065 17.8 209 90 Yes W.19.2X6.16 35 Wall 95 0.065 17.8 164 90 No W.19.2X6.16 36 Wall 137 0.065 17.8 2.54 90 No W..19,2X6.16 37 Wall 139 0.065 17.8 .344 90 Yes W.19.2X6.16 38 Wall 63 0.06.5 17.8 344 90 No W.19.2X6.16 39 Wall 17 0.065 17.8 2;99 90 No W.19.2X6.16 40 Wald 147 0.065 17.8 119 90 Yes W.19.2X6.16 41 Door 24 0.336 0 164 90 Yes None 4,2 Wall 81 0.064 17.8 209 90 No GWALL.R19 to mech 43 Roof 486 0.025 38 n/a 0 Yes R.38.2X4.24A attic COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Utah Lindell Residence Date.. 05/07/01 13:20:32 MICROPAS5 v5.10 File -UTAH Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4.1 100Rec PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments 1ZONE 9 SlabEdge 10 SlabEdge 2ZONE 25 SlabEdge 26 SlabEdge 3ZONE 32 SlabEdge 33 SlabEdge 4ZONE 44 SlabEdge 45 SlabEdge Orientation 1ZONE 1 Window 2 Window 3 Door 4 Door 5 Window 6 window 7 Window 8 Window 9 Window 2ZONE 10 Window 11 Door 12 Window 13 Door 14 Window 1S Door 16 Window 17 Window 18 Window 19' Window 20 Window 2'1 Door 22 Window 23 Window 24 Window 25 Window 26 Door 27 Window 28 Skylight 3ZONE 29 Door 30 Door 110 0.760 R-0 No To Outside 18 0.510 R-0 No To garage 2'02 0.760 R-0 No To Outside 19 0.510 R-0 No to garage 5S 0.760 R-0 No To Outside 16 0.510 R-0 No To gar/mech 92 0.760 R-0 No To Outside 9 0.510 R-0 No To meth FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC Front (SW) 30.0 0.620 0.71.0 209 90 BldShade/0.2 Front (SW) 57.0 0.620 0.710 209 -90 B1dShade/0.2 Left (NW) 64.0 0.740 0.690 299 90 BldShade/0.2 Left (NW) 72.0 0.740 0.690 299 90B1dShade/0.2 0.740 Left (N) 25.0 0.570 0.670 344 90 B1dShade/0.2 Back (NE) 15.0 0.570 0.670 2.9 90 BldShade/0.2 Right (SE) 42.0 0.740 0.680 119 90 Standard/0.76 Right (SE) 12.0 0.740 0.680 119 90 Standard/0.76 Right (S) 17.5 0.620 0.710 164 90 Standard/0,76 Front (SW) 32.5 0.620 0.710 209 90 Front (SW) 93.0 0.740 0.690 20.9 90 Front (SW) 39.0 0.6.20 0.710 209 90 Front (SW) 4.8.0 0.550 0.650 209 90 Front (SW) 14.0 0.620 0.710. 209 90 Right (S) 56.0 0.740 0.690 164 90 Front (W) 31.5 0.620 0.710 254 90 Left (NW) 9.8 6.620 0.710 299 9.0 Left (N) 5.5 0.740 0.680 344 90. Left (N) 18.0 0.740 0.680 344 90 Left (NW) 18.0 0.740 0.680 299 90 Left (N) 64.0 0.740 0.690 344 90 Back (NE) 20.0 0.740 0.680 29 90 Back (NE) 42.0 0.740 0.680 29 90 Back (E) 21.0 0.620 0.710 74 90 Right (SE) 38.5 0.620 0.710 119 90 Back (NE) 1.08.0 0.740 0.690 29 90 Back (NE) 39.0 0.626 0.710 29 90 Horz 9.0 0.940 0.,730 269 0 Right (S) 64,.0 0.740 0.690 164 90 Right (S) 64.0 0.740 0.690 164 90 B1dShade/0.2 B1dShade/0.2 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 B1dShade./0.2. Standard/0.76 .Standard/0.76 Standard/0.76 Standard/0.16 Standard/0.76 Standard/0.76 -Standard/0.76 B1dShade/0.2 Standard/0.76 Standard/0.76 None/1 B1dShade/0.2 B1dShade/0.2 Standard/'0.68 Blind/0.47 Standard/0.68 Blind/0.47 Standard/0.6"8 Standard/0.6.8 Standard/0.68 Standard/0.68 Blind/0.47 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Blind/0.47 Blind/0..47 Blind/0.47 Bland/0.47 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 Blind/0.47. Blind/0.47 COMPUTER METHOD SUMMARY Page 4 C -2R Project Title....,,.... Utah Lindell Residence Date__05/n7/n7 7i-qn.q7 MICROPASS v5.10 File -UTAH Wth-CTZ1-5S92 Program -FORM C -2R U8e1-#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4.1 100Rec FENESTRATION SURFACES Interior Shade Type/SHGC Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Blind/0.47 Blind/0.4.7 Blind/0.47 Blind/0.47 Standard/0.68 OVERHANGS AND SIDE FINS -Window-- Overhang Left Fin Right Fin Area Left Rght. Surface (sf') Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 1ZONE 2.0 0.0 7 Area U- 6.0 Act Window Exterior Shade Orientation 2ZONE 5.0 (sf) Value SHGC: Azm Tilt Type/SHGC 31 Window Right (S) 20.0 0.740 0.680 1.64 90 B1dShade/0.2 32 Window Right (S) 6°.0 0..740 0.680 164 90 S1dShade/0.2 33 Window Front (W) 6.0 0.740 0.680 254 90 B1dShade/0.2 34 Window Back (E) 15.0 0.740 0.680 74 90 BldShade/0.2 4ZONE n/a n/a n/a n/a n/a n/a 3.0 5.0 39 Window Front (W). 30.0 0.740 0.680 254 90 B'ldShade/0.2 36 Door Left (NW) 64.0 0.740 0.690 299 90 B1dShade/0.2 37 Window Left (N) 32.0 0.620 0.71.0 344 90 Standard/0.76 38 Window Right (SE) 9.0 0.740 0.680 11.9 90 Standard/0.76 39 Window Right (SE) 24.0 0.570 0.670 119 90 Standard/0.76 Interior Shade Type/SHGC Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Blind/0.47 Blind/0.4.7 Blind/0.47 Blind/0.47 Standard/0.68 OVERHANGS AND SIDE FINS -Window-- Overhang Left Fin Right Fin Area Left Rght. Surface (sf') Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 1ZONE 2.0 0.0 7 Window 42.0 6.0 9 Window 17.5 5.0 2ZONE 5.0 0.0 19. Window 18.0 4.5 20. Window_ 18.0 4.5 21 Door 64.0 8.0 23 Window 42.0 7.0 24 Window 21.0 7'.0 4'ZONE 0.0 n/a 37 Window 32.0 8.0 39 Window 24.0 6.0 7.0 2.0 0.0 n/a, n/a n/a n/a n/a n/a n/a n/a 3.5 5.0 0.0 0.0 3.0 0.0 5.0 0.0 0.0 0.0 0.0 4.5 5.0 0.0 n/a n/a n/a n/a, n/a n/a n/a n/a 4.5 5.0 0.0 n/a n/a n/a n/a n/a n/a n/a n%a 8.0 3.0 0.6 n/a n/a n/a n/a n/a n/a n/a n/a 6.0 3.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 3.0 5.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 4.0 3.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 4.0 1.5 0.0 0.0. 0.0 0.0 1.5 0.0 0.0 1.5 0.0 Location/Comments INTER -ZONE SURFACES Area Insul Form 3 ,Surface (sf) U -value R-val Reference IZONE/2ZONE 1 Wall 255 0.386 R-0 w.0..2X4.16 3 Door 40 0.330 R-0 None 2ZONE/3ZONE 2 Wall 760 0.386 R-0 w.0.2X4.1.6 4 Door 68 0.330 R-0 None Location/Comments COMPUTER METHOD SUMMARY Page 5 C -2R Project Title.......... Utah. Lindell Residence. Date..05/07/01 13:20:32 MICROPAS5 v5.10 File -UTAH Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4..1 100Rec HVAC SYSTEMS Minimum Duct SLAE SURFACES Tested Duct ACCA Duct System Type Area Location R -value Leakage Manual D Slab Type (sf) 1ZONE 1ZONE Furnace Standard Slab 986 AFUE Attic R-4.2 No 3ZONE 0.743 ACSplit 12.00 SEER Standard Slab 790 R-4.2 No No 0.596 OZONE Standard Slab 468 Furnace 0.800 THERMAL MASS Attic R-4.2 Area Thick Heat Conduct- Surface. ACSplit Mass Type (sf) (in) Cap ivity UIMC R -value Location/Comments 2ZONE 0.596 3ZONE 1 InteriorHorz 125 1.0 24.0 0.67 1.70 R=DiO cabinet tops 2 S1abOnGrade 970 3....5 28.0 0.98 4.60 R-0.0 Tile 3 SlabOnGrade 996 3.5 28.0 0.98 1.80 R-2.0 Carpet HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Large Gas Recirc/TimeTemp 1 n/a 100 R-0 Minimum Duct Duct Tested Duct ACCA Duct System Type Efficiency Location R -value Leakage Manual D Eff 1ZONE Furnace 0.800 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 2ZONE Furnace 0.800 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 3ZONE Furnace 0. 8.00 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 4ZONE Furnace 0.8.00 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Large Gas Recirc/TimeTemp 1 n/a 100 R-0 COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... Utah Lindell Residence Date..05/07/01 13:20:32 MICROPASS v5.10 File -UTAH Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4.1 100Rec WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light '1 Large 0.909 n/a 0.0126 R-Ii/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC. specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Zonally Controlled HVAC System. This budding incorporates non-standard Fenestration Shading. This building incorporates a High Mass Design. This building incorporates non-standard Water Heating System Zone 1 - Master Suite REMARKS Zone 2 - Living Area Zone 3 - Guest bedrooms Zone 4 - Casitas Milgard fenestration or better CONSTRUCTION ASSEMBLY Page 1 3R Ptoject Title.......... Utah Lindell Residence Date..05/07/01 13:20:32 MICROPAS5 v5.10 File -UTAH Wth-CTZ1SS92 Program -FORM 3R User4-MP1017 Uaer-Carole Christensen Run-Drpl2.80R19.30.4.1 10ORec Parallel. Path Method Reference Name W.19.2X6..16 Description .... Wall R-19 2x6 16oc Type ........... wall R -Value ........ 17.8 Hr-sf=F/Btu Framing Material ..... Type ..... Description .. Spacing ..... 'Framing Frac.. Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Name Description O. FILM.EX Exterior air film: winter value I. STUCC0.0.88 0.875. in stucco 2. BLDG.PAPER Building paper (felt) 3c. BATT.R1.9 R-19 batt insul (cavity - 5.5 in) 3f. FIR.2X6 2x6 fir 4. GYP.0_50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways FIR. 2X6 Wood 2x6 fir. 16 inches on center 0.15 Total Unadjusted R -Values Cavity Frame R -Value R -Value 0.17 0.17 0.17 0.17 0.06 0.06 17.80 -- -- 5.45 0.45 0.45 -,0.68 0.68 19.34 6.98 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-F Total R -Value: 1 / 0.065 15.28 hr--sf.-F/Btu CONSTRUCTION ASSEMBLY Page 2 3R Project T:tle.�......... Utah Lindell Residence Date..05/07/01 1.3:20 MICROPASS v5.10 File -UTAH Wth-CTZ15S'92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4.1 100Rec Parallel Path Method Reference Name.. GWALL.R19 Description ,... Wall R-19 2x6 16oc Type Wall R -Value 17.8 Hr-Sf-F/Btu Framing Material ...... Type ..... Description .. Spacing .... Framing Frac.. Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FIR, 2X6 Wood 2x6 fir 16- inches on center 0!.15 FRAMING ADJUSTMENT CALCULATION Cavity Ftaming Total U -Value: (1 / 19.55 x 0.85) + a / 7.19 x 0.15) = 0.06:4 Btu/hr-sf-F Total R -Value: 1 / 0.064 = 15.55 hr-sf-F/Btu Material Cavity Frame Name Description R -Value R -Value 0.. FILM'.,EX Exterior air film: winter value 0.17 0.17 1. GYP.0.5'0 0.50 in gypsum or plaster board 0.45 0.45 3C. BATT.R19 R-1.9.batt insul (cavity = 5.5 in) 17.80 -- if. FIR.2X6 2x6 fir -- 5.45 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM. IN. WLL Inside air film: heat sideways 0-68 0.68 Total Unadjusted R -Values 19.55 7.19 FRAMING ADJUSTMENT CALCULATION Cavity Ftaming Total U -Value: (1 / 19.55 x 0.85) + a / 7.19 x 0.15) = 0.06:4 Btu/hr-sf-F Total R -Value: 1 / 0.064 = 15.55 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 3 3R Project Title.......... Utah Lindell Residence. Date..05/07/01 13:20:32 MICROPAS5 v5.10 :File -UTAH Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-Drp12.80R19.3.0.4.1 10ORec Parallel Path Method Reference Name . R.38.2X4.24A Description .... Roof R-38 2x4 24oc Type ............. Roof. R -Value ........ 38 Hr-sf-F/Btu Framing Material ..... Type .... Description .. Spacing ..... Framing Frac.. Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FIR. 2X4 Wood 2x4 fir 24 inches on center 0.07 Material Cavity Frame Name 'Description R -Value R -Value O. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.CEMENT Asphalt -cement shingles 0.21 0.21 2. BLDG.PAPER Building paper (.felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5. BATT.R27.0 R-27 batt insulation 27.00 27.00 6c. RATT.RII.0 R-11 batt insul (cavity > 3.5 .in) 11.00 -- 6f. FIR.2X4 2x4 fir -- 3.46 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R -Values 40. 9.2 33.39 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 4.0.92 x 0..93) + (1 / 33.39 x 0.07) = 0.025 Btu/hr-sf-F Total R -Value: 1 / 0.025 m 40.28 hr-of-F/Btu CONSTRUCTION ASSEMBLY Page 4 3R Project Title.......... Utah Lindell Residence Date. .05/07/01 13:20:32 MICROPASS v5.10 File -UTAH Wth-CTZ15S92 Program -FORM 32, User#-MP1017 User -Carole Christensen Run-Dt;p12.80R19.30.4.1 10ORec Parallel Path Method Reference Name . W.0.2X4.1.6 Description .... Wall R-0 2x4 16oc Type ........... wall R -Value 0 Hr-sf-F/Btu Framing Material FIR.2X4 Type ........ Wood Description .. 2x4 fir Spacing .... 16 inches on center Framing Frac.. 0.15 Sketch of ConstructioniAssembly LIST OF CONSTRUCTION COMPONENTS .Material Name Description 0. FILM.EX Exterior air film: winter value 1. STUCCO.0.88 0.8.75 in stucco 2. BLDG.PAPER Building paper (felt) 3c. AIR.WLL,3.50 3.5 in & greater air space: heat s,idewys 3f. FIR.2X4 2x4 fir 4. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION Cavity Framing Cavity Frame R -Value R -Value 0.17 0.17 0.17 0.17 0.06 0.06 0.85 -- -- 3.46 0.4.5 0.45 0:68 0.68 2.38 5.00 Total U -Value: (1 / 2.38 x 0.8.5) f (1 / 5.00 x 0.15) = 0.386 Btu/hr-s£-F Tota. R -Value: 1 / 0.386 = 2.59 hr-sf-F/Btu HVAC SIZING Page 1 HVAC Project Title.......... Utah Lindell Residence Date..0.5/07/01 13:20:32 Project Addre ss........ 55-710 Cherry hills ******* PGAW, La Quinta, CA *x5.10* Documentation Author... Carole Christensen ******* Bui ing Permit Carole Christensen 47-596 Lake Canyon Drive Plan Check Date Aguanga, CA 92536 800-735-8152 Field Check/ Date Climate Zone.. 15* Compliance Method...... MICROPASS v5.10 for 1998 Standards by Enercomp, Inc_ MICROPAS5 v5.10 File -UTAH Wth-CTZ15S92 Program. -HVAC SIZING User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30.4.1 100Rec* GENERAL INFORMATION Floor Area ................. 4210 sf Volume. .. .. ............ 46811 Cf Front Orientation..... Front Facing 209 deg (SW) Sizing Location............ PALM DESERT Latitude. .... 33.7 degrees Winter Outside Design ...... 32 F Winter Inside Design.,..... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. .. . 34 F Interior Shading Used No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Sensible Load.................... 97947 131862 Latent Load ...................... n/a 26372 Minimum Total Load 9794.7 158235 Note: The loads shown -are only one of the criteria affecting the selection of HVAC equipment. Other relevant. design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh)- Opaque Conduction and Solar.....:. 27994 12460 Glazing Conduction............... 36331 32507 Glazing Solar .................... n/a 55550 Infiltration..................... 24718 16358 Internal Gain .................... n/a 3000 Ducts............ ........................... 8904 11987 Sensible Load.................... 97947 131862 Latent Load ...................... n/a 26372 Minimum Total Load 9794.7 158235 Note: The loads shown -are only one of the criteria affecting the selection of HVAC equipment. Other relevant. design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... Utah Lindell Residence Date-- 05/07/01 13:20:32 MICROPASS v5.10 File -UTAH Wth-CTZ15'S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen Run-Drpl2.80R19.30.4.1.10ORec HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE '1ZONE' Floor Area... .................... 986.25 sf Volume ............................ 9369 cf ZONE 12ZONE' Floor Area.... ...........:....... Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6785 3021 Glazing Conduction............... 8671 7758 Glazing Solar.... . .............. n/a 14003 Infiltration..................... 4947 3274 Internal Gain .................... n/a 0 Ducts ............................ 2040 2806 Sensible Load.......... ........ 22444 30.86.2 Latent Load......., ............... n/a 6172 Minimum Zone Load 22444 37034 ZONE 12ZONE' Floor Area.... ...........:....... 1966.13 sf Volume ........................... 24.969 cf Heating Cooling Description (Btuh) (Stuh) Opaque Conduction and Solar...... 11826 531.3 Glazing Conduction .............. 18569 16614. Glazing Solar.. .................. n/a 29908 infiltration ................... 1.3185 8725 Internal Gain .................... n/a 3000 Ducts.... ........................ 4358 6356 Sensible Load ........ ... ....... 47937 69916 Latent Load ...................... n/a 13983 Minimum Zone Load 47937 83899 HVAC SIZING Page 3 HVAC Project Title ........... Utah Lindell Residence Date. .05/07/01 13:20:32 MICROPASS x5.10 File -UTAH Wth-CTZ15S9.2 Program -HVAC SIZING User#-MP1017 User -Carole Christensen Run-Drp12.80R19.30i4.1 100Rec ZONE 13ZONEI Floor Area .................... 789.62 sf Volume.......... ................. 7896 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar.... ................. Infil.tration..................... Internal Gain .................... Ducts... ......................... Heating Cooling (Btuh) (Btuh) 3.930 1852 4,921 4403 n/a 528.8 4169 2759 n/a 0 1302 1430 Sensible Load. .................... 14323 LatentLoad ...................... n/a Minimum Zone Load 14323 ZONE 'OZONE' Floor Area ....................... 468 sf Volume........ ... 4577 cf 15732 3146 18879 Heating Cooling Description (Btuh) (Etuh) Opaque Conduction and Solar...... 5453 22'75 Glazing Conduction ............... 4170 3731 glazing Solar....... ............. n/a 6352 'Infiltration................ ..... 2417 15.99 Internal Gain .................... n/a 0 Ducts.............. .......... ... 1204 1396 Sensible Load .................... 13244 15353 Latent Load....... .............. n/a 3071 Minimum Zone Load 13244 18423 INSTALLATION CERTIFICATE (Page 1 of 7) CF-6R Site Address Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required; however, use of this form to provide the information is optional.) After completion of final inspection; a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(b).. HVAC SYSTEMS: Heating Equipment Equip. N of Efficiency Duct Duct or Heating Heating Type (pkg. CEC Certified Mfr Name. Identical (AFUE, etc.)' Location Piping Load Capacity heat Dump) and Model Number Systems r",IR VduaI (attic. etc_) R -value (B1hr) (B)rAr) Cooling Equipment Equip. CEC Certified Compressor N of Efficiency Duct Cooling Cooling Type.(pkg. Unit Mfr Name and Identical (SEER, etc.)' Location Duct Load Capacity heat Dump) Model Number Systems D!MlR valuel (attic. etc 1 R value (ROAr) (Bt16r) 1. _> reads, greater than or equal to. 1, the undersigned, verify that equipment .listed above is: 1) is the actual equipment installed, 2) equivalent to or more efficient than that specified inthe certificate of compliance. (Form CF -1R) submitted for compliance with the Energy Efficiency Standariis for residential buildings, and 3) equipment that meets or exceeds the appropriate requirements for manufactured. devices (from the.Appliance Effciency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner WATER HEATING SYSTEMS: Distribution IfRecir N of Rated= Taak Effi- External Heater CEC Certified Mfr Type (Std, culation. Identical Input Oi W Volume ciency2 Standby' Insulation Type . Name A Model Number, Point -of -Use) Control Type Systems or Btu/hr) (gallons) (EF, RE) Loss(%) R value' 2 For small gas storage {rated input of lean than or equal to 75,000 Btulbr� electrle resistance and beat pump water heaters, list Energy Factor. For large gas storage water beaters (rated input of greater than .75,000 Btulhr), list Recovery Efficiency, Standby Loss and Rated Input For instantaneous gas waterbeaters, list Recovery Efficiency and Rated Input 3. R-12 external insulation is mandatory for storage water beaters with an energy factor of less than 0.58. Faucets & Shower Heads: All faucets and showerheads installed are certified to the Commission, pursuant•to Title 24, Part 6, Section 111. 1, the undersigned, verify that equipment listed above my signature is: 1) the actual equipment installed; 2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1R) submitted for compliance with. the Energy Eflkiency Standards for residential buildings; and 3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the App/Mnce Erklency Regulations or Part 6), where applicable. Signature, Date, COPY TO: Building Department HERS.Provider (if applicable) Building Owner at Occupancy Installing Subcontractor (Co. Name) OR General, Contractor (Co. Name) OR Owner July 1, 1999 INSTALLATION CERTIFICATE (Page 2 of 7) CF -6R Site Address Permit'Number FENESTRATION/GLAZING: Total Quantity Interior or Product. Product of Me. Exterior -Shading U -Value' (5 SHGC' (5 M of Product Square Device or CommentvLocation/ ManufacturedBrandName CF- IRvalue) 2 CF -IR value? Penes (Ootionat) Feet Overhane SpecialFea (GROUP LIKE PRODUCTS) 2. 3. _ 4. _ 5. _ 6. 7. 9. _ 10. _ 11. 12. —_ 13. _ 14. _ 15. ' Manufactured fenestration products use the values from the product label. Field fabricated fenestration products use:the default values from Section 116 of the Energy Efficiency Standards. ' Installed U -value must be less than or equal to values from CF -IR. Installed SHGC must be less than or equal to values from CF= 1R, or a shading device (interior, exterior or overhang) is installed as specified on the CF -1R. Alternatively; insmIled-weighted average U -values for the total fenestration.area.are less than or equal to values from CF -1R. I, the undersigned, verify that the fenestration/glazing listed -above my signature: 1) is the actual fenestration product installed; 2) is equivalent to or has a lower U -Value and lower SHGC than that specified in the certificate of compliance (Form CF -1R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and 3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #s (if applicable) Item #s (if applicable) Signature, Date Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Item #s Signature, Date Installing Subcontractor (Co. Name) OR (if applicable) General. Contractor (Co. Name) OR Owner OR Window Distributor COPY TO.: Building Department HERS Provider (if applicable) Building Owner at Occupancy July 1, 1999 INSTALLATION CERTIFICATE (Page 3 of 7) CF -6R Site Address Permit Number DUCT DIAGNOSTICS This building obtained compliance credit for: ❑ Duct sealing ❑ Duct Area Reduction ❑ ACCA Manual D design and installation CREDIT FOR REDUCED DUCT SURFACE AREA OR LOCATION Duct Location* Exterior. Measured Surface Exterior Area Surface Area ❑ Attic ❑ Crawlspace ❑ Basement ❑ Other Design ❑ Duct Design on Plans ❑ Installed duct diameters match plans ❑ TXV installed ❑ Access to TXV valve (if.installed) ❑ No TXV, Fan air flow (CFM) Duct Sealing ❑ Duct Leakage Measured ❑Measured leakage (CFM) *Ignore ducts in HVAC Fan air flow (CFM)T_ (measured or calculated as conditioned space. ❑CFM = 0.7 x A.. for CZ 8 through 15 Only a check is ❑ required for CFM )-= 0.5 x A,. for CZ 1 through 7 & 16 location credit. - or, if the equipment size is known, the largerof I or 2. 1. ❑CFM = 400 x Cooling Capacity in Tons or 2. E3 am = 21.7 x Heating Capacity in Thousands ofBtu.per hour) Leakage divided by HVAC Fan:aittow (must be:5 0.06) For AEROSOL TYPE SEALANTS ONLY - The following diagnostic, testing; was completed: ❑ Duct Fan Pressurization, at rough -in measured leakage CFM) CHECK AFTER FINISHING WALL:: ❑ Pressure pan test ❑ House pressurization test ❑ Visual Inspection of Duct Connections Provide Follow-up Test Results or Inspection Results on a Separate Page ❑ This certifies that the duct surface area and duct locations were verified When compliance credit is claimed for duct surface area reductions and, duct location improvements beyond those covered by default assumptions, builder employees orsubcornractors shall certify that they have verified that the duct surface area and locations match those on the plans and shall indicate the duct surface area in each duct location on the CF -6R. ❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF - 6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date Installing Subcontractor (Co. Name) OR Performed General Contractor (Co. Name) COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy July 1, 1999 INSTALLATION. CERTIFICATE (Page 4 of 7) CF -6R Site Address Permit Number BUILDING ENVELOPE LEAKAGE DIAGNOSTICS This building obtained compliance credit for:. ❑ Envelope sealing using diagnostic testing (CF -1R) Diagnostic Testing Results Needed for Compliance Measured (from CF -1 R) Blowerdoor Test Results Building Envelope Leakage (CFM @ 50 Pa) Leakage level equivalent to an SLA of 3.0 from CFA R Minimum Building Leakage equivalent to an SLA of 1.5 from CF -1 R (CFM a@ 50 Pa) ❑ Yes ❑ No Is design leakage less than the SLA 3.0 equivalent (from CF -1R)? ❑ Yes ❑ No Is mechanical ventilation installed? (Required if design is less than 3.0 SLA) ❑ Yes ❑ No Is measured leakage (without fans operating) less than minimum in.the above Table (1.5 SLA from CF -1R)? ❑ Yes ❑ No Is mechanical supply ventilation installed to assure house pressure does not go below minus 5 Pascal. relatift to outside ambient with all exhaust fans operating? Mechanical Ventilation Fill in Table if mechanical ventilation is installed _ Used for Compliance Measured (from CF -1 R) Actual Continuous Mechanical Ventilation (CFM)' Continuous Mechanical Supply Ventilation (CFM) Required to maintain -5 Pa if building , envelope leakage is less than minimum (see above) Total Power Consumption of Continuous Mechanical Ventilation (Watts)2 ❑ This certifies that the building envelope, leakage was verified. When compliance credit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall certify that they have verified that the building leakage level matches that used for compliance on the CF -IR and, shall document the leakage levels required for compliance and the tested infiltration values on the CF -6R. ❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Test Performed Signature COPY TO: Building Department HERS Provider (if applicable) Date Testing Subcontractor (Co. Name) OR General Contractor (Co. Name) ' When mechanical ventilation. is required, CFM lessthan 0.047 CFM per square foot of conditioned floor area indicates failure to achieve compliance. 2 As determined .from label on fan or manufacturers literature. July 19 1999 INSTALLATION CERTIFICATE I (Page 5 of 7) CF -6R Site Address Permit Number The following is an explanation of many of the input values required on this form: HVAC SYSTEMS Heating Eouinment'Tvne must be one of the following - Furnace: Gas (including Liquefied Petroleum Gases) or oil -fired central furnace & space heater Boiler. Gas or oil -fired boiler PckgHeatPump: Packaged central heat pump SplitHeatPump: Split central heat pump RoomHeatPump: Room heat pump LgPkgHeatPump: Large packaged heat pump (Z 65;000 Btu/hr output) Electric: Electric resistance. heating (fixed HSPF =3.413); radiant electric,resistance (fixed' HSPF = 3.55) CombinedHydro: Reference water heater under water heating systems below CEC Certified Manufacturer Name & Model Number from applicable Commission approved appliance directory. # of Identical Systems is for those' systems with the same efficiency, duct location, duct R -value and capacity. Efficiency from applicable Commission certified appliance.directory: Duct (or Piping,) Location is attic, crawl space, CVC crawl space, conditioned, space, unconditioned space or none. Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacture's data. Heating/Cooling Load refer to Commission approved load calculation procedure. Heating/Cooling Capacity from the. applicable Commission certified appliance directory. Note: location elevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's literature). Cooling Eauinment Tvue must be one of the following: SplitAirCond: Split system air conditioner PckgAirCond': Packaged air conditioner Split Heat Pump: Split system heat pump PckgHeatPump: Packaged.heat pump RoomHeatPump: Room heat pump LgPkgHeatPump: Large packaged heat pump (2 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available RoomAirCond: Room air conditioner. Minimum SEER varies* LgPkgAirCond Large packaged air conditioner G2 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available EvapDirect: Direct evaporative cooling system. For compliance calculation purposes, fixed values: SEER - 11.0; duct location = attic; duct linsulation R value = 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, fixed values: SEER =13.0; duct location = attic; duct insulation R -value = 4.2 *Refer to Energy Commission publication Appliance Efficiency Regulations, P400-92-029 July 1, 1999 .� INSTALLATION CERTIFICATE (Page 6 of 7) CF -6R Site Address Permit -Number The following is an explanation of many of the input values required on this form: WATER HEATING SYSTEMS nintrihutinn Rvatems Refer to Ro_sidontinl Unnunl fnr mnm details - Standard: Standard — Supply, pressure based system, no pumps Pipe Insulation: Pipe Insulation on all 3/4 -inch pipes POU/HWR: Point of Use/Hot Water Recovery System Recire/NoControl: Recirculation loop with no controls Recirc/Timer: Recirculation loop with a timer Recirc/Temp: Recirculation loop with temperature control Reckc)Time+Temp: Recirculation loop with a timer and temperature control RecirclDemand: Recirculation loop with demand control Water Heater Tune Information Needed' FENESTRATION/GLAZING Fenestration: Energy Factor Recovery Efficiency Standby Loss Rated Input Storage Gas, Oil or:Electric Yes No No No Heat Pump Yes No No No Instantaneous Gas No Yes No No Instantaneous Electric Yes No No No Large Storage Gas No Yes Yes Yes Indirect Gas (Boiler) No Yes (AFUE) No Yes FENESTRATION/GLAZING Fenestration: Windows, sliding glass doors, French doors, skylights, garden windows, and any door with.more than one square foot of glass Operator Type: Slider, hinged, fixed U -Value: Installed U -value must be less than.or�equal to value.from CF -1R OR Installed weighted average U -value for the total fenestration area. is less than orequal to value from CF -IR SHGC: Installed SHGC must be, less than or equal to value .from CF -1R OR Installed. weighted SHGC foi the total fenestration area,is less than or equal to value from.CF-1R OR An interior shading device, overhang, or exterior shading device is installed consistent with the CF -IR Shading.Device: Include when the building complied using an Interior shading device: blinds, opaque roller shades, blinds (do not list draperies), an exterior shading device: woven sunscreen, louvered sunscreen, low sun angle sunscreen, roll - down awning, roll -down blinds or slats (do not list bug screen), or an overhang include depth in. feet July 1, 1999 INSTALLATION CERTIFICATE (Page 7 of 7) CF -6R Site Address Permit Number The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3 of 6): TYPE OF CREDIT Refer to Residential Manual Chapters 4 and S for more details: Reduced Duct Surface Area: Calculated as the outside area of the duct. Areas must be measured and verified by a HERS rater. Improved Duct Location: Supply duct located' in other than attic, as verified by location of registers (does not require HERS rater verification). Catastrophic Leakage: Pressure pan test readings must be less than 1.5 Pascal at a house pressure of 25 Pascal. TXV: Access cover required to facilitate verification.. Infiltration Reduction: Infiltration is measured withoutmechanical ventilation operating. Mechanical ventilation is required for very tight house construction when credits for infiltration reduction using diagnostic testing are being used for achieving compliance. These very tight houses are defined as those with SLA of less than 1.5. The compliance documentation (CF -1R) will contain the measured CFM target value from a blower door test at 50 Pascal pressure difference that represents this SLA of I.S. Mechanical ventilation is also required if the builder chooses to design the building to use mechanical ventilation and claims a credit for infiltration belowan SLA of 3.0. The compliance documentation (CF -1R) will, contain the measured CFM target value that represents this, 3.0 SLA. If the builder claims credit in a design. for infiltration reduction that is at an SLA of 3.0 or higher, and the actual .measured SLA is 1.5 or greater, then mechanical ventilation is not required. If the SLA in this case were below 1.5, then mitigation (such. as mechanical ventilation) would be required. July 1, 1999 Number and Street , .. •, • h . County Subdlvblon Lot Nurnber Descr p'tiou of IUM1120OU I. ROOF Material Thickness (inches) CEILING Brand Nano Tho mal Resistanco (R•Valuo) San or Blanket Typo Srand''Nanto Thickness (Inches) 'Iltoraaal Resistance (R -Value) Loose Fill Typo Bread, Contractor's. min instailcd wcighVft' _,Ib Minlmutn thicknoss inches Manufacturer's installed weight per square foot to achi'm harmal' RcslV=ce (R•Vsluo) I EXTERIOR WALL Frunc Typo A. Cavity Insulation Thickness (inches) 8 .. Exterior Foam Sheathing Materia}••. • Y— Thickness (inchoO 4. RAISED FLOOR Material Thickness (inches) _- S. SLAB 'FLOORLPERIMMP, Material Thickness (inches) Pcrvnctcr Insulation Depth (inches) 6. FOVNDA71ON WALL Material Thickncss (inches) Brand Huns Ite mal R.osist = (R -Value) Brand Name Thermal Resistance (R•Valuo) Brand Nam* Thermal Reslstutce (R•Value) Brand Name Thermal Resistance (R -V aluc) Brand Name 'Thermal Resistance Declaration I hereby ccnify that the above insulation was hutallcd In tho building at the aboyc locatlon In conformance with the current Energy Efictcncy Standards for rosldentlal buildings (Tltl* 24, Put 6, Callfomla Code of Roguladotts) as indicated on the Ccnificatc of Compliance, where applicable;. 11cm o's Signature, Date rCcm fis Signature, Date Installing. Suboono•aotor (Co. Nemo) OR Ocncral Contractor (Co. Name) OR Own" 10411ing Subcontractor (Co. Name) OR Ocnoral Contactor (Co. Name) OR Owner h m, as $ipaturo. Date instilling Subcontractor (Co. Name) OR Oeneral Contdilor (Co. Namo) OR Owner Milgard Windows NFRC Tested U -Factors for Aluminum Windows SW I= "m"'7 the bem Aluminum And intercept Spacer Without grids or SS/SS & DS/DS with flat grids Standard Frame CaliWatda Window Window DebuhU-Factor CtR/aR CLRR1ARDIDW-WI 0.73 lot It' t•.» 1 Ai....el......wn.t I n a') 1 n 11 1 nee I n ee 1 n cc 1' n 42 1 n Aa I A90 1 rru II 911C Awn Aluminum A Cal,H-bar 0.82 0.77 0.74 0:72 0.65 0.63 0:62 0:39 P-05 91IC Pic Aluminum:Picnire Window Cal H-ber 0.67 6.62 0.60 0.38 0.48 0.45 0.44 0.40 F-03 912C Pie Aluminum Picture WirWow' Cala 0.67 0.62 0.62 0.59 0.50 0.47 0.46 0.41 F-33 710 Pic Aluminum Picturo•Window, std 0.67 0.62 0.60 0:37 0.48' OAS 0.43 0.39 F•C50 S Series Window Series ,I l IOSH Window Type Aluminum Slider Stucco Hollow Sill California Default IMactor Clear Low E 0.82 0.77 CLR 0.77 CU ARooat 0.7S CLRAIARD I.OW-5(2) ARCION 0.66 0.63 C[ R=rr LOW -8(4) AROOtr 0.62 0.58 3TRUC7U AL RATRIo HS -R20 ISIOS Aluminum Single H Stucco 0.82 0.77 0.78 0.76 0.67 0.64 0.62 0.39 DH -R25 910S Case Aluminum Casement Stucco 0.82, 0.77' 0:74 0.72 0.65 0.62 0.61 0.38 C -C35 910S'Awn Aluminum A Stueeo 0.82 0.71 0.74, 0.72 0.65 0.62 0.61 0.58 P-03 91OS.Pic Aluminum Picture Window Sm000 0.67 0.62 0:62, 0.60 0.31 0.47 0.46 0.42 F-05 9125 Pic Aluminum Picture Window Stucco I" 0.67 0.62 0.62 1 0.60 0.51 0.470.46 0.42 F-05 7105 Pic . Aluminum Picture Widow st- 0.67 0:62 0.60 0.57 0.48 0.43 0.43 0.19 FX50 450S Aluminum Slid' Door. stucco 0:72 0.67 0.74 0.72 0.62 0.39 0.58 0.54 SOD -R20 JR -15S lAluminum Radius Window Stucco 0.67 0.62 0.59 0.37 0:47 0.44 0.42 0.38 F-HC4S A specs* glazing option maybe aoi to aO2 lower than shown. (2) Low E2 - Hardeoar (PPG Sangare 300 orLDF). (4) Low E 04 - Softcoat (Cardinal Law E). (3) Thee ratings ort not "CerriJled` mawlal.swndard for Jlberglarris not finished revised 3/5/99 •� _UV Solar Heat Gain Coefficients Aluminum Itlype Glazin No Grids Flat Grids Sculptured: Grids Sliders Or / Cir 0.68 0.63 0.57 1110H / 1180H / 1280H Brz / Clr 0.56 0.52 0.48 Loel72 / Clr 0.39 0.37 0.33 Loe170 / Or 0.36 0.33 0.30 LOF / Clr 0.64 0.58 0.54 Azurlite 0.43 0.40 0.37 Single Huns Clr / Cir 0.68 0.62 0.57 1510 / 1580 /1680 Brz / Cir 0.57 0.52 0.48 Loel72 / Cir 0.40 0.36 0.33 Loel70 / Cir 0.36 0.33 0.30 LOF / Clr 0.63 0.58 0.53 Azurlite 0.44 0.40 0.37 Fixed Clr / Clr 0.71 0.65 0.62 910C / 910 Brz / Cir 0.58 0.54 0.51 Loe172 / Clr 0.39 0.37 0.35 Loel70 / Cir 0.35 0.33 0.31 LOF / Or 0.65 0.60 0.58 Azurlite 0.44 0.41 0.39 710 Clr / Cir • 0.72 0.65 0.59 Brz /Cir 0.59 0.53 0.49 Loel72 / Clr 0.40 0.36 0.33 Loel701 Clr 0.35 0.32 0.30 LOF / Cir 0.66 0.60 0.55 Azurlite 1 0.44 0.40 1 0.37 Casement / Awnings Cir / Cir 0.61 0.57 0.54 910C 1910 Brz / Cir 0.51 0.48 0.45 Loe172 / Clr 0.36 0.33 0.32 Loel70 / Clr 0.33 0.31 0.30 LOF / Clr 0.58 0.55 0.52 Azurlite 0.39 0.37 0.35 Door Cir / Clr 0.69 0.62 0.57 450/415 Brz / Clr 0.57 0.52 0.47 Loel72 / Cir 0.39 0.36 0.33 Loel70 / Clr 0.35 0.33 0.30 _ LOF / Cir 0.64 0.58 0.53 Azurlite 0.44 1 0.40 0.37-