11-0247 (AR) Title 24
~T } • BUILDING ENERGY ANALYSIS REPORT The EnergyPro com • authorized by the PROJECT: Conley Residence Addition 80-266 Hermitage -PGA West La Quinta, CA 92253' Project Designer: Larry W. Lang, P.E. 80-590 Camino San Gregorio Indio, CA 92203-7434 (760) 834-9020 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive \ Palm Desert, Ca 92211 \ k DM -Y- 0 4P 4��o PR 1 r • BY: CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED Date: FOR CONSTRUCTION 4/13/2011 ArE �✓ 13<< ev ��#'•^ �r program has been used to perform the calculations summarized in this compliance report. This program has approval and is ifornia Energy Commission for us;ewl'opedby ith a Residential and Nonresidential 2008 Building Energy Efficiency Standards; This progr En ySoft, LLC — www.energysoft.com. 6712 Run Code: 2411 0 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 4/13/2011 Project Address 80-266 Hermitage -PGA West La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,772 Addition 702 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures --If Yes, A CF -4R must be provided; per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form'for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 4,070 Existing Wall Wood Framed R-13 2,055 Existing Slab Unheated Slab -on -Grade None 4,070 Perim = 448' Existing Roof Wood Framed Attic R-38 702 Radiant Barrier New Wall Wood Framed R-13 737 New Slab Unheated Slab -on -Grade None 702 Perim = 89' New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Right (N) 336.5 1.190 0.68 none none Bug Screen Existing Right (N) 38.0 0.330 0.39 none none Bug Screen New Right (N) 10.0 0.720 0.39 none none Bug Screen Existing Front (E) 109.8 1.190 0.68 none none Bug Screen Existing Front (E) 24.5 0.720 0.39 none none Bug Screen Existing Left (S) 262.5 1.190 0.68 none none Bug Screen Existing Left (SWJ 56.4 1.190 a68 none. none Bug Screen Existing Rear (W 42.5 1.190 0.68 none none Bug Screen Existing Rear (tM 275.2 1.190 0.68 4.0 none Bug Screen Existing Rear (149 146.0 1.190 0.68 2.0 none Bug Screen Existing Rear (tM 99.0 1.190 0.68 10.0 none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Fumace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5. 1 by EnergySoft User Number., 6712 RunCode: 2011-04-13714:45:37 ID: Page 3 of 25 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/13/2011 Project Address 80-266 Hermitage -PGA West La Quinta California Energy Climate Zone CA Climate Zone 15. Total Cond. Floor Area 4,772 Addition 702 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 3.4 0.720 0.39 none none Bug Screen New Front (E) 6.0 0.720 0.39 none' none Bug Screen New Left (S) 80.0 0.330 0.39 none none Bug Screen New Rear (tM 56.0 0.330 0.39 4.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location. R -Value Status I WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-04-13714:45:37 /D: Page 4 of 25 C PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Conley Residence Addition I Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 1411312011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written , justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.30.2x12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. 1 I i . I r f HERS REQUIRED VERIFICATION I Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given.1 j j I E j EnergyPro 5.1 by EnemySoft User Number.' 6712 Run Code: 20 1 1-04-1 3 714:45:37 10: Page 5 of 25 CI • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Conley Residence Addition ❑ Multi Family m Existing+ Addition/Alteration 1411312011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 11.08 16.40 -5.33 Space Cooling 226.60 165.82 60.78 Fans 49.31 36.71 12.60 Domestic Hot Water 5.79 5.79 0.00 Pumps 0.00 0.00 0.00 Totals 292.78 224.73 68.05 Percent Better Than Standard: 23.2 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED a Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) , 1,076 140 Fuel Available at Site: Natural Gas (S) 1,214 399 Raised Floor Area: 0 (W) j 742 619 Slab on Grade Area: 4.772 (N) ( 1,210 293 Average Ceiling Height: 10.5 Roof , 4,772 0 Fenestration Average U -Factor: 1.08 TOTAL: 1,451 Average SHGC: 0.64 Fenestration/CFA Ratio: 30.4 REMARKS STATEMENT OF COMPLIANCE i This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, i a�Ilv I4/13/2011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Si ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Larry W. Lang, P.E. Address 80-590 Camino San Gregorio Name Lary W. Lang JXT4 4 4118111 City/State/zip Indio, CA 92203-7434 Phone (760) 834-9020 Signed License # Date EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-04-13714:45:37 ID: Page 6 of 25 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R • Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1411312011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 4,070 0.049 R-19 0 0 Existing 4.2.1-A4 ExistingResidence Wall 321 0.102 R-13 0 90 Existing4.3.1-A3 ExistingResidence Wall 630 0.102 R-13 0 90 Remove 4.3.1-A3 ExistingResidence Wall 832 0.102 R-13 90 90 Existing 4.3.1-A3 Existing Residence Wall 757 0.102 R-13 180 90.Existing, 4.3.1-A3 Existing Residence Wall 431 0.102 R-13 225 90 Existing 4.3.1-A3 Existing Residence Wall 1031 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Residence Wall 1201 0.102 R-13 270 90 Removec 4.3.1-A3 Existing Residence Slab 4,070 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 702 0.026 R-38 0 20 New 4.2.1-A9 Addition Wall 597 0.102 R-13 0 90 New 4.3.1-A3 Addition Wall 104 0.102 R-13 90 90 New 4.3.1-A3 Addition Wall 16 0.102 R-13 180 90 New 4.3.1-A3 Addition Wall 20 0.102 R-13 270 90 New 4.3.1-A3 Addition Slab 702 0.730 None 0 180 New 4.4.7-A1 Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 9.0 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 2 Window 9.0 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 3 Window 9.0 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 4 Window 43.2 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 5 Window 8.6 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 6 Window 52.7 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 7 Window 21.0 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence Window 48.0 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence •8 9 10 Window Window 21.0 1.190 Default 30.0 1.190 Default 0.68 Default 0.68 Default 0 Existing 0 Existing Single Metal Tinted Single Metal Tinted Existing Residence Existing Residence 11 Window 4.0 0.330 NFRC 0.39 NFRC 0 New Double Metal Tinted Existing Residence 12 Window 4.0 0.330 NFRC 0.39 NFRC 0 New Double Metal Tinted Existing Residence 13 Window 30.0 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 14 Window 10.0 0.720 NFRC 0.39 NFRC 0 Existing Glass Block Existing Residence 15 Window 27.5 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence 16 Window 27.5 1.190 Default 0.68 Default 0 Existing Single Metal Tinted Existing Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hqt-F Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 IBug, Screen 1 0.761 1 16 JBug Screen 1 0.761 1 • EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-04-13T14:45:37 ID: Page 7 of 25 • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1411312011 OPAQUE SURFACE DETAILS Surface Ll- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 7.0 1.190 Default 0.68 Default 90 Existing Single Metal Tinted Existing Residence 18 Window 15.0 1.190 Default 0.68 Default 90 Existing Single Metal Tinted Existing Residence 19 Window 7.0 1.190 Default 0.68 Default 90 Existing Single Metal Tinted Existing Residence 20 Window 8.0 0.720 NFRC 0.39 NFRC 90 Existing Glass Block Existing Residence 21 Window 16.5 0.720 NFRC 0.39 NFRC 90 Existing Glass Block Existing Residence 22 Window 48.0 1.190 Default 0.68 Default 90 Existing Single Metal Tinted Existing Residence 23 Window 10.8 1.190 Default 0.68 Default 90 Existing Single Metal Tinted Existing Residence 24 Window 18.0 1.190 Default 0.68 Default 90 Existing Single Metal Tinted Existing Residence 25 Window 4.0 1.190 Default 0.68 Default '90 Existing Single Metal Tinted Existing Residence 26 Window 24.0 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 27 Window 48.0 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 28 Window 18.0 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 29 Window 18.0 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 30 Window 18.0 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 31 Window 8.0 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 32 Window 20.0 1.190 Default 0.68,Default_J 1801 Existing Single Metal.Trnted Existing Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len FIRL LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 [Bug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2011-04-13T14:45:37 ID: Page 8 of 25 0 CERTIFICATE OF COMPLIANCE: Residential . (Part 4 of 5) CF -1 R Project Name Conley Residence Addition Building Type m Single Family 0 Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/13/2011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 50.0 1.190 1 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 34 Window 58.5 1.190 Default 0.68 Default 180 Existing Single Metal Tinted Existing Residence 35 Window 48.0 1.190 Default 0.68 Default 225 Existing Single Metal Tinted Existing Residence 36 Window 8.4 1.190 Default 0.68 Default 225 Existing Single Metal Tinted Existing Residence 37 Window 40.5 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 38 Window 47.3 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 39 Window 9.5 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 40 Window 80.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 41 Window 22.4 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 42 Window 48.8 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 43 Window 45.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 44 Window 52.2 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 45 Window 54.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 46 Window 45.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 47 Window 2.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Existing Residence 48 Window 80.0 1.190 Default 0.68 Default 270 Removed Single Metal Tinted Existing Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 9.0 5.3 4.01 0.1 4.0 4.0 39 Bug Screen 0.76 1.8 5.3 4.0 0.1 4.0 4.0 40 Bug Screen 0.76 10.0 8.0 4.0 0.1 4.0 4.0 41 Bug Screen 0.76 2.8 8.0 4.0 0.1 4.0 4.0 42 Bug Screen 0.76 7.5 6.5 2.0 0.1 2.0 2.0 43 Bug Screen 0.76 9.0 5.0 2.0 0.1 2.01 2.0 44 Bug Screen 0.76 9.01 5.8 2.0 0.1 2.0 2.0 45 Bug Screen 0.76 9.0 6.0 10.0 0.1 10.0 10.0 46 Bug Screen 0.76 9.0 5.0 10.0 0.1 10.0 10.0 47 'Bug Screen 0.76 48 IBug Screen 0.76 10.0 8.0 4.0 0.1 4.0 4.0 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-04-13714:45:37 ID: Page 9 of 25 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration1 te T41131201 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 49 Window 30.6 1.190 Default 0.68 Default 270 Removed Single Metal Tinted Existing Residence 50 Window 12.0 0.330 NFRC 0.39 NFRC 0 New Double Metal Tinted Addition 51 Window 12.0 0.330 NFRC 0.39 NFRC 0 New Double Metal Tinted Addition 52 Window 3.0 0.330 NFRC 0.39 NFRC 0 New Double Metal Tinted Addition 53 Window 3.0 0.330 NFRC 0.39 NFRC 0 New Double Metal Tinted Addition 54 Window 3.4 0.720 NFRC 0.39 NFRC 0 New Glass Block Addition 55 Window 6.0 0.720 NFRC 0.39 NFRC 90 New Glass Block Addition 56 Window 80.0 0.330 NFRC 0.39 NFRC 180 New Double Metal Tinted Addition 57 Wndow 56.0 0.330 NFRC 0.39 NFRC 270 New Double Metal Tinted Addition 58 Window 36.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Addition 59 Window 80.0 1.190 Default 0.68 Default 270 Existing Single Metal Tinted Addition (1) U -Factor Type: 2 SHGC T e: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt REM Dist Len H t Dist Len H t 49 Bug Screen 0.76 9.0 3.4 4.0 0.1 4.0 4.0 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 7.0 8.0 4.0 0.1 4.0 4.0 58 Bug Screen 0.76 9.0 4.0 4.0 0.1 4.0 4.0 59 Bug Screen 0.76 10.0 8.0 4.0 0.1 4.0 4.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-04-13T14:45:37 ID: Pae 10 of 25 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)' CF -1 R Project Name Conley Residence Addition Building Type © Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1411312011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC Existing 4,070 42,735 1994 Addition 702 7,511 Totals 702 41070 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 3 Central Fumace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status American G52 -75T-75 1 Small Gas No Pipe Insulation 75,000 75 0.78 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 v N a System Name Pipe Length Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried O EnergyPro 5. 1 by EnergySoft User Number: 6712 Run Code: 2011-04-13714:45:37 ID: Pae 11 of 25 r l� 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Onley Residence Addition Date 1411312011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fittinq damper and or a combustion -air control device. 1§1 50(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-8. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-04-13714.45:37 ID: Page 12 of 25 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date onley Residence Addition 1411312011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-04-13714:45:37 ID: Page 13 of 25 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date onley Residence Addition 1411312011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPru 5.1 by EnergySoft User Number. 6712 Run Code: 2011-04-13T14:45:37 ID: Page 14 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Onley Residence Addition Date 4/13/2011 System Name HVAC Floor Area 4,772 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 5,589. Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 75,000 120,482 4,972 2,800 121,200 Total Output Btuh 225,000 0 Output Btuh/s ft 47.2 10,216 8,611 Cooling System oil 0 Output perSystem 50,000 0 0 0 0 Total Output Btuh 150,000 0 10,216 140,915 4,972 0 Total Output ons 12.5 8,611 Total Out utBtuh/s ft 31.4 Total Output(sqft/Ton 381.8 138,422 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 4,800 Existing Lennox Systems 123,897 6,351 225,000 Airflow cfm/s ft 1.01 Airflow cfmfTon 384.0 Outside Air % 0.0% Total Adjusted System Output 123,897 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 6,351 Aug 3 PM 1 225,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 OF 112 OF 112 OF x�j5r Heating Coil Supply Fan 4,800 cfm 111 OF i :ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 10, Outside Air 0 cfm 80/64°F 80/64°F 56/54°F 56/54°F Irl t. Cooling Coil Supply Fan 58 / 55 OF 4,800 cfm I._....._...._ ._.,......_._..._.... .......... 43.3% ROOM MW 78/63°F EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-04-13T14:45:37 ID: Page 15 of 25 • • • ROOM LOAD SUMMARY Date 4/13/2011 Floor Area 4,772 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Existing Residence Existing 1 4,649 100,211 3,676 4,649 100,211 3,676 2,391 103,514 Addition Addition 1 9401 20,271 1,296 940 20,271 1,296 409 17,687 PAGE TOTAL TOTAL* 5,589 120,482 4,972 2,800 121,200 5,589 120,482 4,972 2,800 121,200 . Total includes ventilation load for zonal systems. EnergyPro, 5.1 by EnemySoft User Number: 6712 Run Code: 2011-04-13T14:45:37 /D: Pae 16 of 25 NW C] ROOM HEATING PEAK LOADS Project Name Conley Residence Addition Date 4/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Floor Area 4,070.0 ftZ Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr = 8,775 = 9,221 = 63,455 = 116 = 1,093 = 14,390 = = = = = = = = = = = = = = = = = = = = = = = = = 97,050 44 = 11,231 Default Roof 1978 to Present 4,070.0 0.0490 44 Default Wall 1992 to Present 2,054.6 0.1020 44 Single Metal Tinted 1,211.9 1.1900 44 Double Metal Tinted 8.0 0.3300 44 Glass Block 34.5 0.7200 44 Slab -On -Grade pen .m = 448.0 0.7300 44 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 4,070 X Area another room 10.50 X 0.337 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 103,514 Energ Pro 5.1 by Energ Soft User Number. 6712 RunCode: 2011-04-13T14:45:37 ID: Page 17:of25 • • • ROOM HEATING PEAK LOADS Project Name Conley Residence Addition Date 4/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Floor Area 702.0 ftZ Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R.30.2x12.16) 702.0 X R-21 Wall (W.19.2x6.16) 736.6 X Double Metal Tinted 166.0 X Glass Block 9.4 X Single Metal Tinted 116.0 X Slab -On -Grade perim = 89.0 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 702 X Schedule Air Sensible Area Ceiling Fraction U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F 44 = 44 = 44 = 44 = 44 = 44 = Btu/hr 0.0260 803 0.1020 3,306 0.3300 2,410 0.7200 298 1.1900 6,074 0.7300 2,859 Page Total /60] X 44 AT another room 10.70 X 0.330 Height ACH 1 15,750 = 1,937 TOTAL HOURLY HEAT LOSS FOR ROOM 17,687 EnergyPro 5.1 -by Energ Soft User Number: 6712 Run Code: 2011-04-13T14:45:37 /D: Page 18 of 25 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS 4/13/2011 Room Name Existing Outdoor Dry Bulb Temperature 112 OF Floor Area 4,070.Oft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF ,Outdoor Dailv Range: 34 OF Opaque Surfaces Default Roof 1978 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 4,070.01 0.0490 56.0 320.5 -0.1020 23.0 831.7 0.1020 33.0 756.5 0.1020 26.0 42.6 0.1020 31.0 103.3 0.1020 33.0 0.0 49.0 8.6 49.0 0.0 49.0 52.7 I 0.0 49.0 21.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I FPnPStratinn Window Window Window Window Window Window Window Window Window OriPntatinn (N) (N) (N) (N) (N) (N) (N) (N) (N) Btu/hr 11,168 752 2,800 2,006 135 348 1 17,2081 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 49.0 9.0 49.0 0.0 49.0 9.0 49.0 0.0 49.0 9.0 49.0 0.0 49.0 43.2 49.0 0.0 49.0 8.6 49.0 0.0 49.0 52.7 49.0 0.0 49.0 21.0 49.0 0.0 49.0 48.0 49.0 0.0 49.0 21.01 49.0 Page Total Btu/hr 441 441 441 2,118 422 2,584 1,030 2,354 1,030 10,8611 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 100,211 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Temperature Opaque Surfaces Existing Outdoor Dry Bulb Temperature 4,070.0 ft2 Outdoor Wet Bulb Temperature 78 OF Outdoor Dailv Ranae: 4/13/2011 Area U -Factor CLTD' X X = X X = X X = X X = X X X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (E) (E) (E) (E) (E) (E) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 49.0 30.0 49.0 0.0 21.1 4.0 21.1 0.0 21.1 4.0 21.1 0.0 49.0 7.0 89.4 0.0 49.0 15.0 89.4 0.01 49.0 7.0 89.4 0.0 28.9 8.0 52.0 0.0 28.9 16.5 52.0 0.0 49.0 48.0 89.4 Page Total 112 OF 78 OF 34 OF Btu/hr Btu/hr 1,471 84 84 626 1,341 626 416 858 4,291 1 9,7981 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. _ Equipment 1.0 Dwelling Unit X 1,600 Btu 1,t Infiltration: 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 100,211 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW 0 1 TOTAL HOURLY LA r� �J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature Floor Area 4,070.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: ue Surfaces Orientation Date 4/13/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = 49.0 0.0 49.0 0.0 49.0 X 89.4 = 0.0 49.0 X 49.2 = 0.0 49.0 + + 48.01 X 49.2 = 0.0 49.0 18.0 X X X Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation (E) (E) (E) (S) (S) (S) (S) (S) (S) Shaded Area X X X X X X X X X GLF Unshaded Area + 10.8 + 18.0 + 4.0 + 24.0 GLF X 89.4 = X 89.4 = 0.0 49.0 0.0 49.0 0.0 49.0 X 89.4 = 0.0 49.0 X 49.2 = 0.0 49.0 + + 48.01 X 49.2 = 0.0 49.0 18.0 X X X 49.2 0.0 49.0 + + + 18.0 49.2 0.0 49.0 18.0 49.2 0.0 49.0 8.0 X1 49.2 Page Total 112 OF 78 OF 34 OF Btu/hr 0 Btu/hr 966 1,609 358 1,181 2,361 885 885 885 394 Internal Gain Btu/hr- tu/hrOccu ants Occupants 4.0 Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 252.02 X 34 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 100,211 Latent Gain Btu/hr Occupants 4.0 Occupants X.1 200 Btuh/occ. = 800 Infiltration 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Conley Residence Addition 1 4/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature .112 OF Floor Area 4, 070.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 0.0 49.0 20.0 49.2 0.0 49.0 50.0 49.2 0.0 49.0 58.5 49.2 0.0 49.0 48.0 64.7 0.0 49.0 8.4 64.7 0.0 49.0 40.5 89.4 16.3 49.0 31.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fpnpctratinn Window Window Window Window Window Window Window Window Window OriPntatinn (S) (S) (S) (SIM (SK9 I'm (1/1`9 (w) W Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 49.0 20.0 49.2 0.0 49.0 50.0 49.2 0.0 49.0 58.5 49.2 0.0 49.0 48.0 64.7 0.0 49.0 8.4 64.7 0.0 49.0 40.5 89.4 16.3 49.0 31.0 89.4 9.5 49.0 0.0 89.4 24.8 49.0 55.2 89.4 Page Total Btu/hr Btu/hr 984 1 3,1051 543 3,621 3,571 466 6,151 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ.= 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 252.02 X 34 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 100,2111 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4.771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW M 4 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Conley Residence Addition 1 4/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature 112 OF Floor Area 4,070.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 1 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 22.4 X 49.0 + 0.0 X 89.4 = 1,098 Window 9.8 X 49.0 + 39.0 X 89.4 = 3,969 Window (149 7.5 X 49.0 + 37.5 X 89.4 = 3,720 Window (WJ 8.7 X 49.0 + 43.5 X 89.4 = 4,316 Window (W) 47.4 X 49.0 + 6.6 X 89.4 = 2,914 Window (tM 39.5 X 49.0 + 5.5 X 89.4 = 2,429 Window (IM 0.0 X 49.0 + 2.0 X 89.4 = 179 X + X - X +1 X - Page Total 18,625 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM . 100,211 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 1 2,876 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,676 EnemvPro 5. 1 by EnemySoft User Number: 6712 Runcode: 2011-04-13T14:45:37 ID: Page 23 of 25 s •� • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Conley Residence Addition 1 4/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 702.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: 34 OF ODaaue Surfaces R-38 Roof(R.30.2x12.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W..19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) Orientation (N) (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 702.0 0.0260 56.0 596.6 0.1020 23.0 104.0 0.1020 33.0 16.0 0.1020 26.0 20.01 0.1020 33.0 21.1 12.4 XI 49.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (N) (N) (E) (S) (►M Btu/hr 1,022 350 42 I 2,8821 Shaded Area 0.0 X 0.0 X 0.0 X GLF + + + + + + + + +1 Unshaded Area 12.0 12.0 3.0 3.0 3.4 6.0 80.0 31.2 23.6 GLF X 21.1 = X 21.1 = X 21.1 = X 21.1 = X 28.9 = X 52.0 = X 21.2 = X 44.2 = XI 89.4 = Page Total 21.1 21.1 21.1 0.0 X 21.1 0.0 X 28.9 0.0 X X 28.9 0.0 21.1 24.8 X 21.1 12.4 XI 49.0 Btu/hr 253 253 63 63 98 312 1,693 1,902 2,718 7,356 Internal Gain Btu/hr Occupants 4.0 Occupants X.1 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 I Infiltration: 1.064 X 0.87 X 43.47 X 34 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,2711 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 1 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 43.47 X 0.00276 = 496 Air Sensible CFM Et.A AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,2961 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Conley Residence Addition 1 4/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 702.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 1 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window W 24.8 X 49.0 +' 55.2 X 89.4 = 6,151 X + X = X + X = X + X - X + X = X + X = X + X = X + X = X +1 XI - Page Total 6,151 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 43.47. X 34 = 1,362 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,271 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 43.47 X 0.00276 = 496 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,296 EnerovPro 5.1 by EnemySoft User Number. 6712 RunCode: 2011-04-13T14:45:37 ID: Page 25 of 25