Loading...
11-0247 (AR) Revision 1 Title 24• ` BUILDING ENERGY ANALYSIS REPORT e PROJECT: Conley Residence Addition 80-266 Hermitage -PGA West La Quinta, CA 92253 Project Designer: Larry W. Lang, P.E. 80-590 Camino San Gregorio Indio, CA 92203-7434 (760) 834-9020 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (76_0) 200-4780 1 JI I JUN 10 2011 Job Number: Date: 5/25/2011 C1-fY OF L-A QUINTA BUILDING & SAF PT. APPROVED FOR CONSTRUCTION BY. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnerovPro 5.1 by EnergvSoft User Number. 6712 Run Code: 2011-05-25709:48:17 /D: • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/25/2011 Project Address 80-266 Hermitage -PGA West La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,772 Addition 702 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 4,070 Existing Wall Wood Framed R-13 2,055 Existing Slab Unheated Slab -on -Grade None 4,070 Perim = 448' Existing Roof Wood Framed Attic R-38 686 Radiant Barrier New Wall Wood Framed R-13 747 New Slab Unheated Slab -on -Grade None 702 Perim = 89' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 336.5 0.560 0.32 none none Bug Screen Existing Right (N) 14.0 0.330 0.39 none none Bug Screen New Right (N) 10.0 0.720 0.39 none none Bug Screen Existing Front (E) 109.8 0.560 0.32 none none Bug Screen Existing Front (E) 24.5 0.720 0.39 none none Bug Screen Existing Left (S) 262.5 0.560 0.32 none none Bug Screen Existing Left (SIM 56.4 0.560 0.32 none none Bug Screen Existing Rear (IM 42.5 0.560 0.32 none none Bug Screen Existing Rear (tM 275.2 0.560 0.32 4.0 none Bug Screen Existing Rear (VV) 146.0 0.560 0.32 2.0 none Bug Screen Existing Rear (tM 99.0 0.560 0.32 10.0 none Bug Screen Existing HVAC -SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-05-25T09:48:17 ID: Page 3 of 25 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/25/2011 Project Address 80-266 Hermitage -PGA West La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floo 4,772 r Area Addition 702 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation . Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 8.0 0.390 0.36 none none None New Skylight 8.0 0.390 0.36 none none None New Right (N) 9.4 0.720 0.39 none none Bug Screen New Front (E) 13.4 0.720 0.39 none none Bug Screen New Leh (S) 80.0 0.560 0.32 none none Bug Screen New Rear (lM 56.0 0.460 0.31 4.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 4 of 25 1), U 0 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/25/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.30.2x 12.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro,5.1 by EnemySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 5 of 25 r1 U • - .l PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Conley Residence Addition ❑ Multi Family m Existing+ Addition/Alteration 1512512011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.98 9.50 -4.53 Space Cooling 183.09 125.51 57.58 Fans 39.45 27.51 11.94 Domestic Hot Water 5.79 5.79 0.00 Pumps 0.00 0.00 0.00 Totals 233.30 . 168.32 64.99 Percent Better Than Standard: 27.9% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 1,076 148 Fuel Available at Site: Natural Gas (S) 1,214 399 Raised Floor Area: 0 (10 742 619 Slab on Grade Area: 4,772 (N) 1,210 275 Average Ceiling Height: 10.5 Roof 4,772 16 Fenestration Average U -Factor: 0.56 TOTAL: 1,456 Average SHGC: 0.32 Fenestration/CFA Ratio: 30.5% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and compl te. Documentation Author Company Scott Design and Title 24, Inc, 5252011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company. Larry W. Lang, P.E. Address 80-590 Camino San Gregorio Name Larry W. Lang City/State/Zip Indio, CA 92203-7434 Phone (760) 834-9020 Signed License # Date EnemyPro 5.1 bEne Soft User Number: 6712 RunCode: 2011-05-25T09:48:17 /D: Page 6 of 25 0 L� CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1512512011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 4,070 0.049 R-19 0 0 Existing 4.2.1-A4 Existing Residence Wall 321 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Residence Wall 630 0.102 R-13 0 90 Removec 4.3.1-A3 Existing Residence Wall 832 0.102 R-13 90 90 Existing .4.3. 1-A3 Existing Residence Wall 757 0.102 R-13 180 90 Existing 4.3.1-A3 Existing Residence Wall 43 0.102 R-13 225 90 Existing 4.3.1-A3 Existing Residence Wall 103 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Residence Wall 120 0.102 R-13 270 90 Removec 4.3.1-A3 Existing Residence Slab 4,070 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 686 0.026 R-38 270 20 New 4.2.1-A9 Addition Wall 615 0.102 R-13 0 90 New 4.3.1-A3 Addition Wall 971 0.102 R-13 90 90 New 4.3.1-A3 Addition Wall 16 0.102 R-13 180 90 New 4.3.1-A3 Addition Wall 20 0.102 R-13 270 90 New 4.3.1-A3 Addition Slab 702 0.730 None 0 180 New 4.4.7-A 1 JAddition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 9.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 2 Window 9.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 3 Window 9.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 4 Window 43.2 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 5 Window 1 8.6 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 6 Window 52.7 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 7 Window 21.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 8 Window 48.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 9 Window 21.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 10 Window 30.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 11 Window 4.0 0.330 NFRC 0.39 NFRC 0 New Double Non -Metal Tinted Existing Residence 12 Window 4.0 0.330 NFRC 0.39 NFRC 0 New Double Non -Metal Tinted Existing Residence 13 Window 30.0 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 14 Window 10.0 0.720 NFRC 0.39 NFRC 0 Existing Glass Block Existing Residence 15 Window 27.5 0.560 NFRC 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence 16 lWindow 27.5 0.560 NFRC 1 0.32 NFRC 0 Existing Fleetwood Windows/Doors Existing Residence (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 IBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25709:48:17 ID: Page 7 of 25 C • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1512512011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID TVpe Area Ll -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 7.0 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 18 Window 15.0 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 19 Window 7.0 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 20 Window 8.0 0.720 NFRC 0.39 NFRC 90 Existing Glass Block Existing Residence 21 Window 16.5 0.720 NFRC 0.39 NFRC 90 Existing Glass Block Existing Residence 22 Window 48.0 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 23 Window 10.8 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 24 Window 18.0 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 25 Window 4.0 0.560 NFRC 0.32 NFRC 90 Existing Fleetwood Windows/Doors Existing Residence 26 Window 24.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 27 Window 48.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 28 Window 18.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 29 Window 18.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 30 Window 18.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 31 Window 8.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 32 Window 20.0 0.560 NFRC 0.32 NFRC . 180 Existing I Fleetwood Windows/Doors Existing Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Len H t LExt Left Fin RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 IBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 8 of 25 C RTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1512512011 OPAQUE SURFACE DETAILS Surface U- TyDe Area Factor Insulation Joint Appendix _C_aV_ityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 50.0 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 34 Window 58.5 0.560 NFRC 0.32 NFRC 180 Existing Fleetwood Windows/Doors Existing Residence 35 Window 48.0 0.560 NFRC 0.32 NFRC 225 Existing Fleetwood Windows/Doors Existing Residence 36 Window 8.4 0.560 NFRC 0.32 NFRC 225 Existing Fleetwood Windows/Doors Existing Residence 37 Window 40.5 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 38 Window 47.3 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 39 Window 9.5 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 40 Window 80.0 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 41 Window 22.4 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 42 Window 48.8 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 43 Window 45.0 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 44 Window 52.2 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Existing Residence 45 Window 54.0 0.560 NFRC 0.32 NFRC 270 Fleetwood Windows/Doors Existing Residence 46 Window 45.0 0.560 NFRC 0.32 NFRC 270 Fleetwood Windows/Doors Existing Residence 47 Window 2.0 0.560 NFRC "Existing 0.32 NFRC 270 Fleetwood Windows/Doors Existing Residence 48 Window 80.0 0.560 NFRC 0.32 NFRC 270 Fleetwood Windows/Doors Existing Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Overhang Left Fin Len H t I LExt RExt Dist Len Right Fin H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 9.0 5.3 4.0 0.1 4.0 4.0 39 Bug Screen 0.76 1.8 5.3 4.0 0.1 4.0 4.0 40 Bug Screen 0.76 10.0 8.0 4.0 0.1 4.0 4.0 41 Bug Screen 0.76 2.8 8.0 4.0 0.1 4.0 4.0 42 Bug Screen 0.76 7.5 6.5 2.0 0.1 2.0 2.0 43 Bug Screen 0.76 9.0 5.0 2.0 0.1 2.0 2.0 44 Bug Screen 0.76 9.0 5.8 2.0 0.1 2.0 2.0 45 Bug Screen 0.76 9.0 6.0 10.0 0.1 10.0 10.0 46 Bug Screen 0.76 9.0 5.0 10.0 0.1 10.0 10.0 47 lBug Screen 0.76 48 IBug Screen 0.76 10.0 8.0 4.0 0.11 4.01 4.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T09:48:17 ID: Page 9 of 25 C, i C� J • C RTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Conley Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1512512011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame I Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 30.6 0.560 NFRC 0.32 NFRC 270 Removed Fleetwood Windows/Doors Existing Residence 50 Skylight 8.0 0.390 NFRC 0.36 NFRC 270 New Dual Tint Skylight Addition 51 Skylight 8.0 0.390 NFRC 0.36 NFRC 270 New Dual Tint Skylight Addition 52 Window 3.0 0.330 NFRC 0.39 NFRC 0 New Double Non -Metal Tinted Addition 53 Window 3.0 0.330 NFRC 0.39 NFRC 0 New Double Non -Metal Tinted Addition 54 Window 3.4 0.720 NFRC 0.39 NFRC 0 New Glass Block . Addition 55 Window 6.0 0.720 NFRC 0.39 NFRC 0 New Glass Block Addition 56 Window 13.4 0.720 NFRC 0.39 NFRC 90 New Glass Block Addition 57 Window 80.0 0.560 NFRC 0.32 NFRC 180 New Fleetwood Wlndows/Doors Addition 58 Window 56.0 0.460 NFRC 0.31 NFRC 270 New Fleetwood Fixed Addition 59 Window 36.0 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Addition 60 Window 80.0 0.560 NFRC 0.32 NFRC 270 Existing Fleetwood Windows/Doors Addition (1) U -Factor Type: 2 SHGC T e: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hat Dist Len Hat 49 Bug Screen 0.76 9.0 3.4 4.0 0.1 4.0 4.0 50 None 1.00 51 None 1.00 52 Bug Screen 0.76 53 JBugr Screen 0.76 54 JBug Screen 0.76 55 JBug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 7.0 8.0 4.0 0.1 4.0 4.0 59 Bug Screen 0.76 9.01 4.0 4.0 0.1 4.0 4.0 60 Bug Screen 0.76 10.0 8.0 4.0 0.1 4.0 4.0 EnergyPro 5. 1 by EnergySoft User Number: 6712 RunCode: 2011-05-25709:48:17 ID: Pae 10 of 25 J 1� • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Conley Residence Addition Building Type © Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 5/25/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC Existing 4,070 42, 735 1994 Addition 702 7,511 Totals 702 4,0701 01 0 HVAC SYSTEMS System Name Q!y. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 3 Central Furnace 80 % AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status American G52 -75T-75 1 Small Gas No Pipe Insulation 75,000 75 0.78 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 i� a U) System Name Pipe Length Pipe Diameter Insul. Thick. Qt HP Plenum Outside Buried EnergyPro 5.1 by EnerqySoft User Number., 6712 RunCode: 2011-05-25709:48:17 ID: Pae 11 of 25 4 4 M' NDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Onley Residence Addition Date 5/25/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures. 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heatingand PlumbingSystem Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. ' 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 ID: Page 12 of 25 ti. 4 DATORY MEASURES SUMMARY: Residential Pa e 2 of 3 MF -1 R Name Date y Residence Addition r 5/25/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 13 of 25 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ,onley Residence Addition 5/25/2011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T09:48:17 /D: Page 14 of 25 fry HVAC AC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name onley Residence Addition Date 5/25/2011 System Name HVAC Floor Area 4,772 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 3,469 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 75,000 79,284 4,972 1,994 88,257 Total Output Btuh 225,000 0 Output Btuh/s ft 47.2 6,723 6,270 Cooling System 0 0 Output perSystem 50,000 0 0 0 0 Total Output Btuh 150,000 0 6,723 1 92,730 4,972 0 Total Output Tons 12.5 6,270 Total Output Btuh/s ft 31.4 Total Output s ft/Ton 381.8 1 100,798 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 4,800 Existing Lennox Systems 123,164 6,098 225,000 Airflow cfm/s ft 1.01 Airflow cfm/Ton 384.0 225,000 F Jan 1 AM OutsideAir % 0.0% Total Adjusted System Output 123,164 for Peak Design conditions) TIME OF SYSTEM PEAK 6,098 Aug 3PMl Outside Air cfm/s ft 0.00(Adjusted kot': values above iven at ARI conditions TING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 69 OF 69 OF 113 OF 113 °F Heating Coil Supply Fan 4,800 cfm 112 o F ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79/63°F 79/63°F 55/54°F 55/54°F fn Cooling Coil Supply Fan 57 / 54 OF 4,800 cfm..................__.._..___...... 42.5% ROOM �l 78/63°F EnergyPro5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 15 of 25 f.� • RbOM HEATING PEAK LOADS Project Name Conley Residence Addition Date 5/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Floor Area 4,070.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr Default Roof 1978 to Present 4,070.0 0.0490 44 8,775 Default Wall 1992 to Present 2,054.6 0.1020 44 9,221 Fleetwood Windows/Doors 1,211.9 0.5600 44 29,861 Double Non -Metal Tinted 8.0 0.3300 44 116 Glass Block 34.5 0.7200 44 1,093 Slab -On -Grade perim = 448.0 0.7300 44 14,390 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 4,070 X Area another room 10.50 X 0.337 Height ACH Page Total /60] X AT 63,456 = 11.231 TOTAL HOURLY HEAT LOSS FOR ROOM 72,276 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 17 of 25 • r1 L_J • ROOM HEATING PEAK LOADS Project Name Conley Residence Addition Date 5/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Floor Area 702.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F 44 = 44 = 44 = 44 = 44 = 44 = 44 = 44 = = = = = = = = = = Page Total /60] X 44 AT Btu/hr R-38 Roof(R.30.2x 12.16) 686.0 X 0.0260 785 Dual Tint Skylight 16.0 X 0.3900 275 R-21 Wall (W. 19.2x6.16) 747.2 X 0.1020 3,353 Double Non -Metal Tinted 6.0 X 0.3300 87 Glass Block 22.8 X 0.7200 722 Fleetwood Windows/Doors 196.0 X 0.5600 4,829 Fleetwood Fixed 56.0 X 0.4600 1,133 Slab -On -Grade Perim = 89.0 X X 0.7300 2,859 X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 702 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 10.70 X 0.330 Height ACH 14,044 = 1.937 TOTAL HOURLY HEAT LOSS FOR ROOM 15,981 Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T09:48:17 ID: Page 18 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature Floor Area 4,070.0 ft-- Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: Opaque Surfaces Default Roof 1978 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Orientation (N) (E) 5/25/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 4,070.0 0.0490 56.0 320.5 0.1020 23.0 831.7 0.1020 33.0 756.5 0.1020 26.0 42.6 0.1020 31.0 103.3 0.1020 33.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) 112 OF 78 OF 34 OF Btu/hr 11,168 752 2,800 Z006 135 348 1 17,2081 Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area GLF 9.0 X 23.1 9.0 X 23.1 9.0 X 23.1 43.2 X 23.1 8.6 X 23.1 52.7 X 23.1 21.0 X 23.1 48.0 X 23.1 21.0 X 23.1 Page Total = = = = = = = = = 0.0 23.1 0.0 23.1 0.0 23.1 0.0 23.1 0.0 23.1 0.0 23.1 0.0 23.1 0.0 23.1 0.0 23.1 Btu/hr 208 208 208 997 198 1,216 485 1,108 485 5,111 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. ` E ui ment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,547 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM RtSIDENTIAL ROOM COOLING LOAD SUMMARY Project Name •Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature Floor Area 4,070.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 1� ue Surfaces Orientation 5/25/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = 0.0 23.1 0.0 21.1 0.0 21.1 0.0 42.1 0.0 42.1 0.01 42.1 0.0 52.0 0.0 52.0 0.0 - 42.1 Page Total Page Total Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestratinn Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (E) (E) (E) (E) (E) (E) Shaded Area X X X X X X X X X Unshaded GLF • Area 23.1 + 30.0 21.1 + 4.0 21.1 + 4.0 23.1 + 7.0 23.1 + 15.0 23.1 + 7.0 28.9 + 8.0 28.9 + 16.5 23.1 + 48.0 X X X X X X X X X GLF = = = 0.0 23.1 0.0 21.1 0.0 21.1 0.0 42.1 0.0 42.1 0.01 42.1 0.0 52.0 0.0 52.0 0.0 - 42.1 Page Total 112 OF 78 OF 34 OF Btu/hr 0 Btu/hr 692 84 84 295 631 295 416 858 2,020 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,547 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW. • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS 5/25/2011 Room Name Existing I Outdoor Dry Bulb Temperature 112 OF Floor Area 4,070.0 ft2 I Outdoor Wet Bulb Temperature 78 OF Indoor Div Bulb Temperature 78 OF Outdoor Dailv Ranae: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X X X X X = X X = X X = X X = X X X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Window Window Window Window Window Window Window Window Window Orientation (E) (E) (E) (S) (S) (S) (S) (S) (S) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 23.1 10.8 42.1 0.0 23.1 18.0 42.1 0.0 23.1 4.0 42.1 0.0 23.1 24.0 23.1 0.01 23.1 48.0 23.1 0.0 23.1 18.0 23.1 0.0 23.1 18.0 23.1 0.0 23.1 18.0 23.1 0.0 23.1 8.0 23.1 Page Total Btu/hr Btu/hr 454 757 168 556 1,111 417 417 417 4, Internal Gain Btu/hr- Occupants tu/hrOccu ants 4.0 Occupants X 230 Btuh/occ. = 920 EciuiRment 1.0 Dwelling Unit X 1,600 Btu 1,600 Infiltration: 1.064 X 0.87 X 252.02 X 34 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,5471 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW 0 1 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM r� RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature Floor Area 4,070.0 ftZ Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: Orientation Date 5/25/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF 23.1 = 23.1 = 0.0 23.1 20.0 0.0 23.1 50.0 0.0 23.1 58.5 23.1 = 0.0 23.1 48.0 30.4 = 0.0 23.1 8.4 30.4 = 42.1 = 0.0 23.1 40.5 16.3 23.1 31.0 42.1 = 9.5 23.1 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation (S) (S) (S) (SK9 (SVV) (tM (►M (tM W Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF 23.1 = 23.1 = 0.0 23.1 20.0 0.0 23.1 50.0 0.0 23.1 58.5 23.1 = 0.0 23.1 48.0 30.4 = 0.0 23.1 8.4 30.4 = 42.1 = 0.0 23.1 40.5 16.3 23.1 31.0 42.1 = 9.5 23.1 0.0 42.1 = 42.1 = 24.8 23.1 55.2 Page Total 112 OF 78 OF 34 OF Btu/hr 0 Btu/hr 463 1,157 1,354 1,461 256 1,704 1,681 219 2,895 11,190 Internal Gain Btu/hr- Occupants tu/hrOccu ants 4.0 Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration:. 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62.5471 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR U 17J • RtSIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Conley Residence Addition 5/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Outdoor Dry Bulb Temperature 112 OF Floor Area 4,070.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window NO 22.4 X 23.1 + 0.0 X 42.1 = 517 Window (IM 9.8 X 23.1 + 39.0 X 42.1 = 1,868 Window NO 7.5 X 23.1 + 37.5 X 42.1 = 1,751 Window (VIO 8.7 X 23.1 + 43.5 X 42.1 = 2,031 Window (Vto 47.4 X 23.1 + 6.61 X 42.1 = 1,371 Window (149 39.5 X 23.1 + 5.5 X 42.1 = 1,143 Window (tM 0.0 X 23.1 + 2.0 X 42.1 = 84 X + X - X + X = Page Total 1 8,765 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 252.02 X 34 = 7,896 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,547 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 252.02 X 0.00276 = 2,876 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,676 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-05-25709:48:17 /D: Pa a 23 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name . Conley Residence Addition ROOM INFORMATION DESIGN CONDITIONS 5/25/2011 Room Name Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 702.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temoerature 78 OF Outdoor Dailv Ranae: 34 OF Ooaaue Surfaces R-38 Roof(R.30.2x12.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation (N) (S) I Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = _ = = = 686.0 0.0260 56.0 614.6 0.1020 23.0 96.6 0.1020 33.0 16.0 0.1020 26.0 20.0 0.1020 33.0 21.1 3.0 21.1 0.01 28.9 3.4 28.9 0.0 28.9 6.0 28.9 0.0 28.9 13.4 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Skylight Skylight Window Window Window Window Window Window Window Orientation (►M (tM (N) (N) (N) (N) (E) (S) (►M Btu/hr 999 1,442 325 42 67 1 2,8761 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 21.6 8.0 70.3 0.0 21.6 8.0 70.3 0.0 21.1 3.0 21.1 0.0 21.1 3.0 21.1 0.01 28.9 3.4 28.9 0.0 28.9 6.0 28.9 0.0 28.9 13.4 52.0 0.0 23.1 80.0 23.1 24.8 20.7 31.21 39.1 Page Total Btu/hr 563 563 63 63 98 173 697 1,852 1,734 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu 1,600 Infiltration: 1.064 X 0.87 X 43.47 X 34 = 1,362 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,737 Latent Gain Btu/hr Occupants 4.o Occupants X 20o Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 43.47 X 0.00276 = 496 Air Sensible CFM EIA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 17-J, 174 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Conley Residence Addition 5/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 702.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X j X I= Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (149 12.4 X 23.1 + 23.6 X 42.1 = 1,279 Window (Vl/) 24.8 X 23.1 + 55.2 X 42.1 = 2,895 X + X = X + X - X + Ix = X + X - X + X - X + X - X + X - Page Total 4,174 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 43.47 X 34 = 1,362 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,737 Latent Gain Btu/hr Occupants 4.0 Occupants X 777_200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 43.47 X 0.00276 = 496 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,296 EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-05-25T09:48:17 /D: Page 25 of 25