Loading...
SOL-14-591 Plans�1 tr Q m AMWIT BLVD VICINITY MAP N. T. S. INVERTER WITH DC DISCONNECT SWI' DISCONNECT SWITCH, DEDICATED PHOTO SYSTEM KWH METER (FORM S2, ELECTRIC SERVICE EN 3 4- 5go APN: 762060003-8 LEGAL DESCRIPTION: RECORDED BOOK/PAGE: MB 271/63 SUBDIVISION NAME: TR 28410-2 LOT/PARCEL: 3, BLOCK: NOT AVAILABLE TRACT NUMBER: 28410 6w--144- CITY Cfr LA QUINTA & SAFETY DE & (E CE PROVED ANF R CONSTRUCTIO AR AY XiE 1tt 114tq SY w PV AY AR -01 (E) PALM 1 TREE(S) RENESOLA: JC255M-24/Bb SYSTEM SIZE: 9.945 KW DC (8,655.5 KW DC CEC) SMA, MODEL NO. SB8000US, 240 VAC SQUARE D AC DISCONNECT, MODEL NO. DU222RB, 2 POLE, 60 AMP, 240 VAC EXISTING 200A LOAD CENTER, 120/240 VAC, 1PH, 3 WIRE KAIC REV. DESCRIPTION -a&G _ MRMIT SET PITC a (E) RESIDENCE All construction shall comply with the 2013 California Building, Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes and -the La Quinta Municipal Code. SHEET INDEX PV -01 TITLE PAGE PV -02 LAYOUT PV -03 LAYOUT PV -04 RACKING DETAILS PV -05 RACKING DETAILS PV -06 SLD PV -07 ELECTRICAL CALCULATIONS PV -08 LABELING SYSTEM INFORMATION H INSTALLED BY ARGENT SOLAR ELECTRIC INC., (ASSUMED ON LICENSE NO. CA# 951765. ROOF FOR SLD MAGNETIC TRUE EFFECTIVE CODES ALUMINUM MOUNTING SYSTEM. SEE DETAIL ON ORIENTATION ORIENTATION 2013 CEC PV ARRAY 193' 206' 2013 CBC CIRCUIT BREAKER IN THE MAIN PANEL. 193' 206' STRINGS OF 13, 255 WATT MODUL S I 193' 206' NOTES 1. UTILITY HAS 24 HOUR UNRESTRICTED ACCESS TO UTILITY DISCONNECT AND KWH METERS. 2. 9.945 KW PHOTOVOLTAIC SYSTEM TO BE CONDUIT RUN INSTALLED BY ARGENT SOLAR ELECTRIC INC., (ASSUMED ON LICENSE NO. CA# 951765. ROOF FOR SLD 3. SOLAR MODULES MOUNTED TO ROOF USING CALCULATIONS) AEE SOLAR SNAPNRACK ALUMINUM MOUNTING SYSTEM. SEE DETAIL ON SHEET 3 AND 4. PV ARRAY 4. INVERTER LOCATED ON NORTH SIDE OF PV ARRAY RESIDENCE. AR -02 5. CONNECT SYSTEM VIA 40 AMP/240 VOLT CIRCUIT BREAKER IN THE MAIN PANEL. DATE 6. PV ARRAY CONTAINS THREE PARALLEL STRINGS OF 13, 255 WATT MODUL S I SERIES (39 MODULES TOTAL). al jUk ARGENT SOLAR ELECTRIC INC. 9.945 KW PHOTOVOLTAIC SYSTEM 80225 Cedar Crest LA QUINTA, CA 92253 SIZE PAM R0. PRO= A I PV -01 I BROCK 1300 s LITG#1E1D ROAD. SIF 0 GOODYEAR, AZ 6533E TEL 602-750-23M APPROVALS DATE DRAWN CG 06/20/2, CHECKED PV ARRAY ENGINEER AR -03 R. C DATE I DO NOT SCALE DRAWNGS ARGENT SOLAR ELECTRIC INC. 9.945 KW PHOTOVOLTAIC SYSTEM 80225 Cedar Crest LA QUINTA, CA 92253 SIZE PAM R0. PRO= A I PV -01 I BROCK FIRE DEPARTMENT ARRAY OFFSET CONDUIT RUN (ASSUMED ON ROOF FOR SLD z CALCULATIONS) RAIL �' �19 19 4 �0, ROOF ATTACHMENT PV ARRAY �o AR -03 S 9 `3 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION 1300 S LITCHFlELD ROAD, STE /8 GOODYEAR. AZ &53W ARGENT SOLAR ELECTRIC INC. TEL 602-750-2386 DATE BY APPROVALS DATE DRAWN CG 06/20/20149.945 KW PHOTOVOLTAIC SYSTEM CHECKED 80225 Cedar Crest ENGINEER LA QUINTA, CA 92253 M.G.R. REV. C SIZE PACE N0. PROJECT REV. DESCRIPTION DATE DO NOT SCALE DRAWINGS A PV -03 BROCK BABICH c PERMIT SET 06/20/2014 SCALE NTS I REV. C I SHEET 3 of 8 SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT REVISION: NOTES: — — - STANDARD LAG BOLT SPEC ASSUMES 5/16" LAG BOLTS WITH 2.5" EMBEDMENT —_ IN ROOF STRUCTURAL MEMBERS/RAFTERS - TORQUE ALL 11" HARDWARE TO THE FOLLOWING: SILVER S.S. 10-16 FT -LBS ROOF RAFTERS OR BLACK S.S. 7-9 FT -LBS STRUCTURAL MEMBERS RAIL CAN MOUNT TO EITHER SIDE OF POST (UPSLOPE vs. DOWNSLOPE) - FOR UNEVEN ROOF SURFACES, USE UP TO TWO LEVELING SPACERS PER SNAPNRACK MODULE L FOOT OR STANDOFF. SEE DRAWING MID CLAMPS "STANDARD RAIL LEVELING" FOR DETAILS AND LIMITATIONS MODULE OVERHANG (NOT TO EXCEED 25% OF MODULE LENGTH) / STANDOFFS ARE BOLTED--"iL/ �/ //� / / //44 INTO ROOF RAFTERS ORxx STRUCTURAL MEMBER RAIL SPAN DISTANCE BETWEEN STANDOFFS lI / RAIL END OVERHANG (NOT TO EXCEED 340/b OF ACCEPTABLE RAIL SPAN) It - Illy\VII ENERGYCCORP� DESIGNER ' G McPhwtm SCALE: DNS PART NUMBER DESCRIPTION: III ����n ��11 'MAINSTREAM DRAFTER: D Rym S100 D05 SERIES 100 TYPICAL LAYOUT FR E DATE: 110512 pw Mw no APPROVED BY: NOTE DETAILS PROVIDED BY AEE SOLAR SNAPNRACK SERIES 100 RACKING SYSTEM SHOWN MOUNTED ON STANDOFFS 11" X 2.75" (TYP.) S.S. BOLT WITH SPLIT LOCK WASHER SNAPNRACK MID CLAMP SNAPNRACK CHANNEL NUT UNIVERSAL END CLAMP ASSEMBLY `E A STANDARD SASPLICE STANDARD INSERT SNAPNRACK SPLICE STANDARD BASE i o -&" X j" S.S. BOLTS WITH ® SPLIT LOCK WASHERS SNAPNRACK (3 PER SPLICE) STANDOFF CLAMP SNAPNRACKJ ll" X 2" TYP. (OR 1.5") S.S. BOLT CHANNEL NUT WITH SPLIT LOCK WASHER " LAG BOLT WITH WASHER o SNAPNRACK STANDOFF SHAFT STANDARD (VARIOUS LENGTHS) SNAPNRACK STANDOFF BASE STANDARD 1 -HOLE REVISION: RAIL - - NOTES: - STANDARD LAG BOLT SPEC ASSUMES 5/16" LAG BOLTS WITH 2.5" EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS - TORQUE ALL A" HARDWARE TO THE FOLLOWING: - SILVER S.S. 10-16 FT -LBS - BLACK S.S. 7-9 FT -LBS RAIL CAN MOUNT TO EITHER SIDE OF POST (UPSLOPE vs. DOWNSLOPE) - FOR UNEVEN ROOF SURFACES, USE UP TO TWO LEVELING SPACERS PER L FODT OR STANDOFF. SEE DRAWING "STANDARD RAIL LEVELING"FOR DETAILS AND LIMITATIONS _ GAP RAILS 0.1"-0.2" FOR THERMAL EXPANSION ASSEMBLED SYSTEM (SOLAR PANELS NOT SHOWN) " X 1" S.S. BOLT WITH STEM SHOWN WITH STANDOFF MOUNTING SPLIT LACK WASHER COMPATIBLE WITH ALL ROOF TYPES USE FLASHED L FOOT FOR FASTER INSTALLATION ON COMPOSITION SHINGLE ROOFS SQ2n IIII MAINZ sMENyR�G�CORP. DESIGNER: GMCPheelers SCALE: DNS PART NUMBER: DESCRIPTION: REV IIJn\vJl DRAFTER: 0 Ryan I S100 D03 SERIES 100 ASSEMBLY DETAILS UEC E pv ftWUM - -•-•.« - - - r- APPROVED BY: DATE: 110512 NOTE DETAILS PROVIDED BY AEE SOLAR Renesola: JC255M-24/Bb LOAD RATED DC DISCONNECT 2—#B CU THHN/THWN-2 4� 1—#B CU THHN/THWN-2 GROUND System Size: 9.945 KW OC (8.655.5 KW DC CEC) \ MFR: SQUARE D 13 MODULES PER STRING 13 MODULES PER STRING 13 MODULES PER STRING 1—#8 CU THHN/THWN-2 GROUND Vac=487.5 V, Isc=8.86 A Voc=487.5 V, Isc-8.86 A Voc=487.5 V. Isc=8.86 A L = (CIRCUIT ID: 4) Vmp=395.2 V, imp=8.39 A Vmp=395.2 V. Imp=8.39 A Vmp=395.2 V. Imp=8.39 A 6—®10 CU PV—WIRE 1—/10 CU BARE GROUND 3315 WATT 3315 WATT 3315 WATT F EXPOSETDITO FREE AIR (CIRCUI UTILITY METER EXISTING ELECTRICAL SERVICE ENTRANCE L -::L- I UTILITY GRID 120/240V SINGLE PHASE JUNCTION BOX EXISTING 200 A LOAD CENTER VAC, 1PH, 3 WIRE, 10 KAIC I - 200 A MAIN BREAKER qo°(oI'q,,,t'vto 6—/10 CU THHN/THWN-2 1—y10 CU THHN/THWN-2 GROUND 3/4' CONDUIT (CIRCUIT ID: 2) BODO WATT UTILITY INTERACTIVE INVERTER MFR: SMA, MODEL NO. SB8000US, 240 VAC AFP INCLUDED POINT OF CONNECTION 40A/24OVAC BREAKER (LOCATED AT OPPOSITE END OF BUS FROM SERVICE OCPD CITY OF LA OUINTA BUILDING & SAFETY DEPT. 0V FOR CONSTRUCTION DATE BY �/N trd Ih►�wiv�'CS REV. DESCRIPTION C PERMIT SET AC DC FUSED, 3—STRING COMBINER AND LOAD RATED DC DISCONNECT 2—#B CU THHN/THWN-2 4� 1—#B CU THHN/THWN-2 GROUND DEDICATED PHOTOVOLTAIC SYSTEM 1—#B CU THHN/1HVM-2 NEUTRAL 3/4' CONDUIT. MFR: SQUARE D (CIRCUIT ID: 5) 2—/8 CU THHN/THWN-2 MODEL NO. DU222M 1—#8 CU THHN/THWN-2 GROUND 1—#B CU THHN/THWN-2 NEUTRAL = GROUND 3/4- CONDUIT L = (CIRCUIT ID: 4) 2—#B CU 7HHN/THWN-2 1—#8 CU THHN/THWN-2 GROUND 1—p8 CU THHN/THVM-2 NEUTRAL 3/4' CONDUIT (CIRCUIT ID: 3) 2 POLE, 60 AMP, 240 VAC PHOTOVOLTAIC SYSTEM DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT SVATCH KWH METER (FORM 2S) MFR: SQUARE D 100 AMP, 240 VAC MODEL NO. DU222M LEGEND G = GROUND L = LINE N = NEUTRAL 1300 S UTCHFlEU) ROAD, STE'/8 GOODYEAR, Az 85338 TEL 602-750-2386 APPROVALS DATE DRAWN CG 06/20 2 CHECKED ENGINEER M.G.R. REV. C DATE DO NOT SCALE DRAWINGS ARGENT SOLAR ELECTRIC INC. 9.945 KW PHOTOVOLTAIC SYSTEM 80225 Cedar Crest LA QUINTA, CA 92253 SIZE I PACE N0. I PROECT A PV -06 BROCK BABICH ' 9.945 kW DC Renesola JC255M-24/Bb Ise [A] 8.86 Imp [A] 8.39 Voc IV] 37.5 Vmp [V] 30.4 � I SYSTEM CONFIGURATION Modules per String 13 Number of Strings 3 Number of Inverters 1 Record low temp. [C] -5.00 VOC temp. coefficient [%/Cl -0.3 DC SYSTEM SPECIFICATIONS Operating Current 25.17 Operating Voltage 395.2 Max. System Voltage 487.5 Short Circuit Current 33.225 I j AC SYSTEM SPECIFICATIONS Max. AC Output Current 40.00 Oaeratin a AC Voltace 1240 1 -chase Photovoltaic equipment and systems and all associated wiring and interconnections shall be installed only by qualified persons. Photovoltaic system conductors shall be identified and grouped. The means of identification shall be permitted by separate color coding, marking tape, tagging, or other approved means. The means of grouping shall be wire ties or similar means at least once, and then at intervals not to exceed six (6) feet. CALCULATIONS FOR CURRENT CARRYING CONDUCTORS DC required conductor ampacity [NEC 690.8(B)(1)1: 8.86 A * 1 String * 1.56 = 13.82 A AWG #10, derated ampacity Ambient Temp: 69 deg C Temp Derating Factor: 0.58 40 * 0.58 * 0.8 = 18.56 18.56 A > 13.82 A, therefore DC wire size is valid. AC required conductor ampacity 32A*1.25=40A AWG #8, derated ampacity Ambient Temp: 47 deg C Temp Derating Factor: 0.96 55 * 0.96 * 1 = 52.8 52.8 A > 40 A, therefore AC wire size is valid. I f CALCULATION FOR PV BREAKER Inverter Current: 32 A 32A*1.25=40A Therefore, 40 A overcurrent protection is valid III nihir MAXIMUM SYSTEM VOLTAGE CALCULATI `" Voc =37.5V Temp. Coefficient = -0.3 %/deg C D R GG Record Low Temp. = -5 deg C Temp. difference = 25 deg C - (-5 deg C) = deg C -0.3%/deg C * 30 deg C = -9 % DATE Voc Adjusted = 37.5 V - (37.5 V * -9 %) _ 85 Voc MAX = 40.88 V *13 Modules = 531.44 V LA QUINTA x SAFETY DEPT. 0VEL JSTRUCTION Circuit I.D. # Conductor Run Conductor Size Conductors Per Pole Conductor Quantity Conductor Insulation Ground Size Ground Quantity Ground Insulation Type (CU/AL) Conduit Type Conduit Size Ambient Temp. [deg C] Estimated Distance [FT] 1 ARRAY TO JUNCTION BOX 10 1 6 PV -WIRE 8 1 RHW/USE-2 Cu - 69 30 2 JUNCTION BOXTO INVERTER 10 1 6 THHN/THWN-2 8 1 THHN/THWN-2 Cu EMT 3/4" 69 75 3 INVERTER TO METER 8 1 1 1 1 1 THHN/THWN-2 8 1 1 THHN/THWN-2 Cu EMT 3/4" 47 5 4 METER TO AC DISCONNECT 8 1 1 1 1 1 THHN/THWN-2 8 1 1 1 THHN/THWN-2 Cu EMT 1 3/4" 1 47 1 5 5 AC DISCONNECT TO MAIN PANEL 8 1 1 1 1 1 THHNrrHWN-21 8 1 1 1 THHN/THWN-21 Cu I EMT 1 3/4" 1 47 1 5 REV. DESCRIPTION C PERMIT SET 1300 S. LITCHFlELD ROAD. STE #8 GOODYEAR. AZ 85338 TEL 602-750-2386 APPROVALS DATE DRAWN CG 06/20/2 CHECKED ENGINEER M.G.R. REV. C DATE DO NOT SCALE DRAWINGS ARGENT SOLAR ELECTRIC INC. 9.945 KW PHOTOVOLTAIC SYSTEM 80225 Cedor Crest LA QUINTA, CA 92253 SIZE PACE NO. PROJECT .A PV -07 BROCK BABICH CALE NTS REV. C SHEET i SIGNAGE REQUIREMENTS > RED BACKGROUND > WHITE LETTERING > MIN. 3/8" LETTER HEIGHT > ALL CAPITAL LETTERS > ARIAL OR SIMILAR FONT > REFLECTIVE, WEATHER RESISTANT MATERIAL, UL 969 690.5(C) - INVERTER 690.17/690.54 - AC DISCONNECT 690.17/690.53 - DC DISCONNECT 705.12(D)(7) - PANELBOARD CITY OF LAMM=e BUILDING & SA APS FOR CONSTRUCTIONCEC NDS DATE BYCIRC 690.31(E)(3) FC 605.11.1.2 SITS, JBOXES, ETC. 690.56(6)1705.10 - SERVICE PV power source conductors installed within exposed raceways, cable trays, and other wiring methods, covers or enclosures of pull boxes and junction boxes, and conduit bodies in which any of the available conduit openings are used, shall be marked with the following wording "Photovoltaic Power Source" by means of permanently affixed labels spaced not more than ten (10) feet between labels. (CEC §690.31(0)(3)) 690.35(F) - UNGROUNDED DC CIRCUITS