Loading...
BCOM2016-0031 Title 24r� BUILDING ENERGY ANALYSIS REPORT PROJECT: Washington Park - Ulta Beauty 78-825 Highway 111 La Quinta, CA 92253 Project Designer: LR/Architecture 213 W. Alameda Ave, Suite 203 Burbank, Ca 91502 (818)840-8361 Report Prepared by: Joshua Enriquez, PE, LEED AP 665 Fairmont Ave # 11 Glendale, Ca 91203 213-820-3683 CITY 0 LA'QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION � ► U.1bCFEW DATE,�_,BY Job Number: �tt�tio lb • 0031 AUG 2 3 2016 - 1016 CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 8/17/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed. by EnergySoft, LLC—www.energysoft.com. EnergyPro6byEnergySoft User Number: 1064 ID: 1016 t Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 1 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx A. PROJECT GENERAL INFORMATION 1. Project Location (city) La Quinta 8. Standards Version Compliance2015 2. CA Zip Code 92253 9. Compliance Software (version) EnergyPro 6.8 3. Climate Zone 15 10. Building Orientation (deg) (N) 0 deg 4. Total Conditioned Floor Area in Scope 12,626 ftZ 11. Permitted Scope of Work ExistingAlteration S. Total Unconditioned Floor Area Oft' 12. BuildingType(s) Nonresidential 6. Total # of Stories (Habitable Above Grade) 1 13 Gas Type NaturalGas 7. Total # of dwelling units 0 B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2-yr) § 140.1 BUILDING COMPLIES 1. Energy Component 2. Standard Design (TDV) 3. Proposed Design (TDV) 4. Compliance Margin (TDV) S. Percent Better than Standard Space Heating 9.6 6.6 3.0 31.3% Space Cooling .350.4 179.5 170.9 48.8% Indoor Fans 90.2 81.9 8.3 9.2% Heat Rejection - _ -- -- Pumps & Misc. - 0.4 -- 0.4 - Domestic Hot Water 9.0 9.0 -- 0.0% Indoor Lighting 103.9 103.9 - 0.0% COMPLIANCE TOTAL 563.5 380.9 182.6 32.4% Receptacle 91.3 91.3 0.0 0.0% Process 91.3 91.3 0.0 0.0% Other Ltg -- -- - -- TOTAL 746.1 563.5 182.6 24.S% CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 2 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/rime: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings( 1st Space Cooling: Check envelope and mechanical Compliance Margin By Energy Component /from Table B column 4) 2nd Indoor Fans: Check envelope and mechanical Space Cooling Indoor Fans Space Heating Pumps & Misc. Heat Rejection Domestic Hot Water Indoor Lighting Penally 3rd Space Heating: Check envelope and mechanical no C It 4th Pumps & Misc.: Check mechanical 5th Heat Rejection: Check envelope and mechanical 6th Domestic Hot Water: Check mechanical 7th Indoor Lighting: Check lighting D. EXCEPTIONAL CONDITIONS The building does not include service water heating. Verify that service water heating is not required and is not included in the design. The proposed building includes HVAC components that do not meet the mandatory efficiency requirements. E. HERS VERIFICATION This Section Does Not Apply F. ADDITIONAL REMARKS None Provided CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 3 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 _ Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY Identify which building components use the performance or prescriptive path for compliance. NAu= not in project For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans. Building Component Compliance Path Compliance Forms (required forsubmittal) Location of Mandatory Notes on Plans Envelope ® Performance NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E ❑ NA Mechanical ® Performance NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E ❑ NA Domestic Hot Water ❑ Performance NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E) ' ❑ Prescriptive NRCC-PLB-01-E ® NA Lighting (Indoor Conditioned) ❑ 1Performance Performance NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-OS-E) ❑ Prescriptive NRCC-LTI-01 / 02 / 03 / 04 / 05-E ® NA Covered Process: Commercial Kitchens ❑ 52 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC-01/ 03-E ® NA Covered Process: , Computer Rooms ❑ Performance S3 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC-01/ 04-E ® NA Covered Process: Laboratory Exhaust ❑ Performance S4 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC-01/ 09-E ® NA CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 4 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY The following building components are only eligible for prescriptive compliance. Indicate which are The following building components may have mandatory requirements per Part 6. Indicate relevant tc the project. which are relevant to the project. Yes NA Prescriptive Requirement Compliance Forms Yes NA Mandatory Requirement Compliance Forms ❑ ® Lighting (Indoor Commissioning: §120.8 Uncoriditioned) §140.6 ". NRCC-LTI-01 / 02 / 03 / 04 / 05-E ❑ ® Simple Systems NRCC-CXR-01 / 02 / 03 / 05-E ❑ ® Complex Systems NRCC-CXR-01 / 02 / 04 / 05-E ❑ ® Lighting (Outdoor) §140.- NRCC-LTO-01 / 02 / 03,E ❑ ® Electrical: §130.5 NRCC-ELC-01-E ❑ ® Lighting (Sign) §140.8 NRCC-LTS-01-E ❑ ® Solar Ready: §110.10 NRCC-SRA-01 / 02-E Covered Process: §120.6 NRCC-PRC-01-E ❑ ® Parking Garage NRCC-PRC-02-E ❑ ® Solar Thermal Water NRCC-STH-Ol-E ❑ ® Commercial Refrigeration NRCC-PRC-05-E Heating:.§140.5 ❑ ® Warehouse Refrigeration NRCC-PRC-06/07/08-E ❑ ® Compressed Air NRCC-PRC-10-E ❑ ® Process Boilers NRCC-PRC-11-E Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 5 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/rime: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms frequired forsubmittaQ Pass Fall Envelope ® NRCI-ENV-01-E- For all buildings ❑ ❑ ® NRCA-ENV-02-F- NFRC label verification for fenestration ❑ ❑ • Mechanical - - ® NRCI-MCH-01-E - For all buildings with Mechanical Systems ❑ ❑ ® NRCA-MCH-02-A-Outdoor Air - ❑ ❑ ® NRCA-MCH-03-A—Constant Volume Single Zone HVAC - ❑ ❑ ❑ NRCA-MCH-04-H- Air Distribution Duct Leakage ❑ ❑ ® NRCA-MCH-05-A- Air Economizer Controls - ❑ - ❑ ® NRCA-MCH-06-A- Demand Control Ventilation ❑ ❑ ® NRCA-MCH-07-A—Supply Fan Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-08-A- Valve Leakage Test ❑ ❑ ❑ NRCA-MCH-09-A— Supply Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-10-A- Hydronic System Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-11-A—Auto Demand Shed Controls ❑ ❑ ® NRCA-MCH-12-A- Packaged Direct Expansion Units ❑ ❑' ❑ NRCA-MCH-13-A-Air Handling Units and Zone Terminal Units ❑ -❑ . ❑ NRCA-MCH-14-A- Distributed Energy Storage ❑ ❑ ❑ NRCA-MCH-15-A—Thermal Energy Storage ❑ ❑ ❑ NRCA-MCH-16-A- Supply Air Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-17-A— Condensate Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-18-A- Energy Management Controls Systems ❑ ❑ ❑ NRCV-MCH-04-H- Duct Leakage Test ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-081220i6-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 6 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required/orsubmittal) Pass Fail Plumbing ❑ NRCI-PLB-01-E - For all buildings with Plumbing Systems ❑ ❑ ❑ NRCI-PLB-02-E - required on central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-03-E - Single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-21-E - HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-22-E - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-21-H- HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-22-H - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-STH-01-E - Any solar water heating _❑ ❑ Indoor Lighting ❑ NRCI-LTI-01-E - For all buildings ❑ ❑ ❑ NRCI-LTI-02-E - Lighting control system, or for an Energy Management Control System (EMCS) ❑ ❑ ❑ NRCI-LTI-03-E - Line -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting ❑ ❑ ❑ NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a corwention center a conference room, or a theater ❑ ❑ ❑ NRCI-LTI-OS-E -Lighting Control Credit Power Adjustment Factor (PAF) ❑ ❑ ❑ NRCI-LTI-06-E - Additional wattage installed in a video conferencing studio ❑ ❑ ❑ NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls. ❑ ❑ ❑ NRCA-LTI-03-A- Automatic daylighting controls ❑ ❑ ❑ NRCA-LTI.04-A - Demand responsive lighting controls ❑ ❑ Outdoor Lighting ❑ NRCI-LTO-01-E—Outdoor Lighting ❑ ❑ ❑ NRCI-LTO-02-E- EMCS Lighting Control System ❑ ❑ ❑ NRCA-LTO-02-A - Outdoor Lighting Control ❑ ❑ Sign Lighting ❑ NRCI-LTS-01-E—Sign Lighting ❑ ❑ Electrical ❑ NRCI-ELC-01-E - Electrical Power Distribution ❑ ❑ Photovoltaic ❑ NRCI-SPV-01-E Photovoltaic Systems ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01•E Page 7 of 18 - Project Address: 78-825 Highway 111 La Quinta 92253 - Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required forsubmittal) Pass Fail Covered Process ❑ NRCI-PRC-01-E Refrigerated Warehouse. ❑ ❑ ❑ NRCA-PRCDI-F- Compressed Air Systems ❑ ❑ ❑ NRCA-PRC-024- Kitchen Exhaust ❑ ❑ ❑ NRCA-PRC-03-F-Garage Exhaust ❑ ❑ ❑ NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls ❑ ❑ ❑ NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls ❑ ❑ ❑ NRCA-PRC-C6-F- Refrigerated Warehouse- Air Cooled Condenser Controls ❑ ❑ ❑ NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor ❑ ❑ ❑ NRCA-PRC-08-F- Electrical Resistance Underslab Heating System ❑ ❑ I. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information) 1. Total Conditioned Floor Area 12,626 ft2 S. Number of Floors Above Grade 1 Confirmed 2. Total Unconditioned Floor Area 0 ft2 6. Number of Floors Below Grade 0 3. Addition Conditioned Floor Area 0 ft2 4. Addition Unconditioned Floor Area 0 ft2 7. Opaque Surfaces & Orientation 8. Total Gross Surface Area 9. Total Fenestration Area 10. Window to Wall Ratio North Wall 1,132 ft2 560 ft2 49.5% ❑ ❑ East Wall Oft, 0 ft2 00.0% ❑ ❑ South Wall 1,496 ft2 0 ft2 00.0% ❑ ❑ West Wall 4,079 ft2 0 ft2 00.0% ❑ ❑ Total 6,707 W S60 ft2 08.3% ❑ ❑ Roof - 12,626 ft2 Oft, 00.0% ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty N RCC-PRF-01-E Page 8 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 C: Iculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration . Irput File Name: 1016-ULTA.cibdx J. FENESTRATION ASSEMBLY SUMMARY . § 110.6 Confirmed 1. 2. 3. 4. 5. 6. 7. B. 9. Fenestration Assembly Name / Tag or I.D. Fenestration Type Certification Methodl Assembly Method Area ft1 � Overall U-factor Overall SHGC Overall VT IS N Storefront Glazing Vertical Fenestration DefaultPerformance SiteBuilt 560 0.71 0.73 0.88 N ❑ ❑ every mnaneoTenesvanan snaunave a cert0leo 1- tanel -ropoale or use me ctC derault tables found In Table 110.E-A and Table 1. 0.6-a. Center of Glass (COG) values ore for the glass -only, determined by the manufacturer, and are shown for rose of-ifimbon. Site -built fineslrodon values are mlrulated per Nonresidmdal Appendix NA6 and are used in the anoWs. 1 Slatw, N. New, A -Altered, E-Existing Taking compliance credit for fenestration shading devices? (if "Yes", see NRCC-PRF-ENV-DETAILS for more information) No K. OPAQUE SURFACE ASSEMBLY SUMMARY § 120.7/ § 140.3 Confirmed 1. 2. 3. 4. 5. 6. 7. 8. Surface Name Surface Type Area (ftz - Framing Type Cavity R-Value Continuous R-Value U-Factor/F-Factor / C-Factor ;, N 8 CMU Wa117 ExteriorWall 5575 NA 0 NA U-Factor: 0.366 E ❑ ❑ R-20 Metal Deck Roof9 Roof 12626 NA 0 NA U-Factor: 0.490 E ❑ ❑ R-15 Wall Metal Studll - ExteriorWall 1132 NA 0 NA U-Factor: 0.418 A 1 01,0 R-13 Wall Metal Stud15 InteriorWall 0 NA 0 NA U-Factor: 0.345 A ❑ ❑ Slab On Grdde17 Underground Floor 12626 NA 0 - NA F-Factor: 0.730 E ❑ I ❑ ssatus. w w--erea, t - txls0ng L. ROOFING PRODUCT SUMMARY I § 140.3 Confirmed 1. 2. 3. 4. S. 6. 7. Product Type Product Density Aged Solar Thermal SRI Cool Roof Roofing Product (lb/ft) Reflectance Emittance Credit Description R-20 Metal Deck Roof9 50.06 0.08 0.75 NA No NA ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Ver-'ion: NRCC-PRF-01-E-08122016-3995, Report Generated at: 2016-09-17 22:36:18 i Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 9 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx M. HVAC SYSTEM SUMMARY (see NRCC-PRF-MCH-DETAILS for more information) § 110.1 / § 110.2 Dry System Equipment I (Fan & Economizer info included below in Table N) Confirmed 1. 2. 3. 4. S. 6:_ 7. 8. 9. 10. 11. System Type 3 Total Heating Supp Heat Supp Heat Total Coolingto Efficiency Acceptance Testing V v Equip Name q p E ul T e q p yp (Simple or Qty Output Source (Y/N) output Output Required? (Y/N) Complex 4) (kBtu/h) (kBtuh) (kBtu/h) Cooling Heating 6 RTU 1thru 4 SZVAVAC (Packaged3Phase) Complex 4 104 No 0 113 EER-13.8 AFUE-80.0 Yes. N ❑ ❑ Wet System Equipment Pumps Confirmed 12. 13. 14. 1S.' 16. 27. 18. 19. 20. 21. 22. 23. 24. Equip Name Equip Type City Vol (gal) Rated Capacity Efficiency Standby Loss Tank Ext. R City GPM HP VSD - N w (kBtu/h) Value (/N) c Non Res BaseWaterHeater Storage 1 19 20 EF:0.646 NA NA NA NA NA No N ❑ ❑ ,..y..»,e,n c,tu,r.,ncn. mauvesrurna nnana mguru., earpump; etc. 21, System Equipment includes boilers, chillers, cooling towers, water heaters, etc. - 3 Simple Systems must complete NRCC-CXR-03-E commissioning design review form 4 Complex systems must complete NRCC-CXR-04-E commissioning design review form S A summary of which acceptance tests one applicable is provided in NRCC-PRr-MCH-DETAILS 6 Status: N-New, A -Altered, E-Existing Discrepancy between modeled and designed equipment sizing? (if "Yes", see Table F. "Additional Remarks" for an explanation) No N. ECONOMIZER & FAN SYSTEMS SUMMARY' § 140.4 Confirmed 1. 2. 3. 4. 5. Outside AU Supply Fan Return Fan v ti Equip Name q P Economizer Type d TSP TSP CFM CFM HP BHP (inch- Control CFM HP BHP (inch Control (if present) WC) WC) rRTU 1 thru 4 J89 4000 3.000 3.000 2.86 Variable5peedDrive NA NA NA NA NA DifferentialEnthalp ❑ Y CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 r Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 10 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx O. EQUIPMENT CONTROLS I § 120.2 Confirmed 1. 2. 3. v N - Equip Name Equip Type Controls 1 Zones With CO2Sensor Vent. Control RTU 1 thru 4 - SZVAVAC Differential Enthalpy Economizer Q ❑ No Supply Air Temp. Control No Optimum Start NonResBaseSHWSystem Service Hot Water, Primary Only Fixed Temperature Control, No DDC ❑ ❑ P. SYSTEM DISTRIBUTION SUMMARY § 120.4/ § 140.4(I) Dry System Distribution Confirmed 2. 3. 4. 5. d N d Equip Name - Equip Type Duct Leakage and Sealing Required per 140.4(1) Duct Leakage will be verified NA2 Aland Ducts Insulation R-Value Location RTU 1 thru 4 SZVAVAC No No 8 Conditioned ❑ ❑ Does the Project Include Zonal Systems? (if "Yes", see NRCC-PRF-MCH-DETAILS for system Information) No Does the Project Include a Solar Hot Water System? (if "Yes", see NRCC-PRF-MCH-DETAILS for system Information) No Multifamily or Hotel/ Motel Occupancy? (If "Yes", see NRCC-PRF-MCH-DETAILS for DHW system Information) No Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info), § 140.6 Confirmed 1. 2. 3. 4. 5. 1 Occupancy Type Conditioned Floor Area = Installed Lighting Power Lighting Control Credits Additional (Custom) Allowance 9 'a T 6 — (ft=) (Watts) (Watts) Area Category Footnotes Tailored Method (Watts) ❑ ❑ (Watts) Retail Merchandise Sales, 12,626 0 0 0 ❑ ❑ Wholesale Showroom Building Totals: 12,626 0 0 0 See Table 140.6-C 1 See NRCC-07-01-E/or —diliwed spares CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 11 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/rime: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx 3Lighting infor"Indon for existing spaces modeled is not included in the table R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)' This Section Does Not Apply - 'IJlighting power densides were used in the compliance model Building Departments will need to check prescriptive tams for Luminaire Schedule details. S1. COVERED PROCESS SUMMARY— ENCLOSED PARKING GARAGES § 140.9 This Section Does Not Apply S2. COVERED PROCESS SUMMARY —COMMERCIAL KITCHENS § 140.9 This Section Does Not Apply 53. COVERED PROCESS SUMMARY -COMPUTER ROOMS § 140.9. This Section Does Not Apply S4. COVERED PROCESS SUMMARY— LABORATORY EXHAUSTS § 140.9 This Section Does Not Apply T. UNMET LOAD HOURS Thermal Zone Name Cooling Unmet Load.Hour Umit for proposed Cooling Unmet Load Hours Heating Unmet Load Houi Limit for 1proposed Heating Unmet Load Hours Thermal Zone Thermal Zone 1-First Floor-Retail/Sales - 150 1744.75 - . 150 0 U. ENERGY USE SUMMARY Energy Component Standard Design Site (MWh) Proposed Design Site (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Space Heating 0.0 -- — 62.8 43.5 19.3 Space Cooling 141.0 78.8 62.2 -- - -- Indoor Fans 36.9 41.7 -4.8 Heat Rejection Pumps & Misc. 0.3 — -- -- -- __ Domestic Hot Water -- - -- 68.5 68.5 0.0 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 12 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx U. ENERGY USE SUMMARY Energy Component - Standard Design Site (MWh) Proposed Design Site w (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Indoor Lighting 52.4 52.4 0.0 - -- -- COMPLIANCE TOTAL 230.6 172.9 57.7 131.3 112.0 19.3 - Receptacle 45.9 -45.9 0.0 -- -- -- Process 45.9 45.9 0.0 -- -- -- Other Ltg _ TOTAL 322.4 264.7 57.7 131.3 - 112.0 - 19.3 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 'Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 13 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Datefrime: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx DOCUMENTATION AUTHOR'S DECLARATION STATEMENT § 10-103 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Joshua Enriquez, PE, LEED AP Signature: Company: Address: 665 Fairmont Ave # 11 Signature Date: City/State/Zip: Glendale Ca 91203 CEA Identification (If applicable): Phone:213-820-3683 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 2 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 3 I affirm that 1 am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Responsible Envelope Designer Name: John Gilmore Deenihan, RA Company: LR/Architecture Signature: Address: 213 W. Alameda Ave, Suite 203 Date Signed: City/State/Zip: Burbank Ca 91502 Declaration Statement Type: Phone: (818)84D-8361 Title: License #: C9147 Responsible Lighting Designer Name: ' Company: Signature: NOT IN SCOPE Address: Date Signed: City/State/Zip: Declaration Statement Type: Phone: Title: License M Responsible Mechanical Designer Name: Joshua Enriquez, PE, LEED AP Company: EnergyLogics, Inc. Signature: Address: 665 Fairmont Ave #11 Date Signed: City/State/Zip: Glendale CA 91203 Declaration Statement Type: Phone: 213-820-3683 Title: License #: CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 14 of 18 Project Address: 78-825 Highway 111 La Quinta92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 ' Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx NRCC-PRF-ENV-DETAILS -SECTION START - A. OPAQUE SURFACE ASSEMBLY DETAILS Confirmed 2. 3. 4.. v m v d — Surface Name Surface Type Description of Assembly Layers Notes 8 CMU Wa117 ExteriorWall Concrete - Solid Grout - 1051b/ft3 - 8 in. ❑ ❑ - - Air - Cavity - Wall Roof Ceiling -4in. or more Built-up roofing - 3/8 in. R-20 Metal Deck Roof9 Roof Plywood -1/2 in. ❑ ❑ Concrete - 140 Ib/ft3 - 4 in. - - ' Stucco - 7/8 in. R-15 Wall Metal Stud11 EMeriorWall Vapor permeable felt -1/8 in. ❑ ❑ Air -Wall - 3 1/2 in. / - Gypsum Board - 1/2 in. ` Stucco - 7/8 in. R-13 Wall Metal Stud15 InteriorWall " permeable felt - 1/8 in. VaporAir - ❑' - Wall - 3 1/2in. Gypsum Board - 1/2 in. Slab Type = UnheatedSlabOnCrade Slab On Grade17 UndergroundFloor - Insulation Orientation .= None ❑ • ❑ - - Insulation R-Value = RO B. OVERHANG DETAILS (Adapted from NRCC-ENW02-E) This Section Does Not Apply - C. OPAQUE DOOR SUMMARY This Section Does Not Apply - - CA Building Energy Efficiency Standards- 2013 Nonresid ential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 15 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx NRCC-PRF-MCH-DETAILS -SECTION START- r ` A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2013-NRCC-MCH-03-E) Confirmed 1. DESIGN AIR FLOWS 2. VENTILATION (§ 120.1) = o c z Z v T Z g_ Z D3 fc D3 Ov ^p Z g in Z .G Z a r „ !c LAZ CONDITIONED n O r O D �L T 9 O g 3 O - t� O n '+ m g Z C 3 D C f1 m D v r ZONE NAME c O 3 a '-' t i a D O m O a s �- Z a n 3 3 3 Z A 3 z o z g D _ D a r c D A z Z z< G1 Z Gi o o i T 5 g a a a Z v O i n Z 3 3 1-First Floor-Retail/Sales RTU 1 thru 4 4,000 2,600 0.65 NA NA N RTU 1 thru 4 12,626 NA 210 15.0 3,156 3,156 E y ❑ ❑ TOTAL 12,626 NA NA NA NA ❑ ❑ B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY § 140.4 1. 2. 3. 4. 5. 6. 7. 8. Confirmed Rated Capacity Airflow (cfm) Fan System ID System Type ty City Economizer Zone Name � r w Heating Cooling Design Min. - BHP Cycles ECM Ratio Motor First Floor-Retail/Sales3- VAVNoReheatBox 4 NA NA NA 1-First Floor-Retail/Sales 4000 2600 0.65 NA NA ❑ ❑ ❑ TRM \UST FAN SUMMARY lion Does Not Apply' I EQUIPMENT SUMMARY — (Adapted from NRCC-PLB-01) lion Does Not Apply CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park: Ulta Beauty NRCC-PRF-01-E Page16 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx E. MULTI -FAMILY CENTRAL DHW SYSTEM DETAILS This Section Does Not Apply F. SOLAR HOT WATER HEATING SUMMARY (Adapted from NRCC-STH-01) This Section Does Not Apply G. MECHANICAL HVAC ACCEPTANCE TESTS & FORMS (Adaptedfrom 1013-NRCC-MCH-0I-E) J§ RA4 Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that may be submitted. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). 3 n 3 n 3 n 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Test Description x b x b x n x b n x b n x b n x b n x b n x n x i+ n x n x n x n x n x n x n x Confirmed ► r• i+ �. �. �. �. v < c o o n Equipment w A D 0 ° �' a n 'O o S m < c Requiring Nof o 3' o < '° m Testing or units 1D o n < m m e c c X ,', S a n m o 9 Verification D 0 D W m M C n c 3 v o f m � NonResBase 1 - SHWSystem — -- — -- — -- -- -- -- -- -- — — -- -- ❑ ❑ RTU 1 thru 4 4 X X — X X X — -- -- X — — — ❑ ❑ H. EVAPORATIVE COOLER SUMMARY This Section Does Not Apply NRCC-PRF-LTI-DETAILS -SECTION START - IA. INDOOR CONDITIONED LIGHTING CONTROL CREDITS (Adapted from NRCC-LTI-02-E) § 140.6 This Section Does Not Apply CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 17 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: 1016-ULTA.cibdx B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E) This Section Does Not Apply - §130.1(a) = Monuol area controls, §130.0(b) - Multi ttuel,§130.1(c) = Auto Shut -Off; §130.1(d) = Mandatory Daylight, §130.1(e) = Demond Respamlve C. TAILORED METHOD CONDITIONED LIGHTING POWER ALLOWANCE SUMMARY AND CHECKLIST (Adapted from NRCC-LTI-04-E) § 140.6 . General lighting power (see Table D) 0 General lighting power from special function areas (see Table E) NA Additional "use it or lose it" (See Table G) 0 Total watts 0 D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E) § 140X-11) This Section Does Not Apply E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E) § 140.6(c) 3H Room Number Primary Function Area Illuminance Value (LUX) Room Cavity Ratio (Table G) Allowed LPD Floor Area (ft') Allowed Watts Confirmed Pass Fall NA NA NA NA NA NA .NA . ❑ 1 ❑ F. ROOM CAVITY RATIO (Adapted from NRCC-LTI.04-E) Rectangular Spaces Room Number Task/Activity Description Room Length (ft) Room Width (ft) Room Cavity Height (ft) RCR Confirmed Pass Fall NA NA NA NA NA NA I ❑ ❑ Non -Rectangular Spaces This Section Does Not Apply ry . w, vppncvan, spaces are iaiev unvei one rvan-nec�engu�er.apvices mv�e CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016.08.17 22:36:18 Project Name: Washington Park - Ulta Beauty NRCC-PRF-01-E Page 18 of 18 Project Address: 78-825 Highway 111 La Quinta 92253 Calculation Date/Time: 22:35, Wed, Aug 17, 2016 Compliance Scope: ExistingAlteration Input File Name: ' 1016-ULTA.cibdx G. ADDITIONAL "USE IT OR LOSE IT" (Adapted from NRCC-LTI-04-E) 1. 2. 3. 4. Allowed Watts Confirmed Wall Display Combined Floor Display and Task Lighting Combined Ornamental and Special Effects Lighting Very Valuable Merchandise v o 0 0 0 0 0 ❑ ❑ S. Wall Display This Section Does Not Apply 6. Floor Display and Task Lighting This Section Does Not Apply 7. Combined Ornamental and Special Effects Lighting This Section Does Not Apply 8. Very Valuable Merchandise This Section Does Not Apply H. INDOOR & OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E) I § 130.4 Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description Indoor Outdoor Confirmed NRCA-LTI-02-A NRCA-LTI-03-A NRCA-LTI-04-A , NRCA-LTO-02-A Equipment Requiring Testing or Verification p of units Switch Occ SensorsAuto Time Auto Daylight Demand Responsive Outdoor Controls n� w - Occupant Sensors 0 ❑ ❑ ❑ ❑ ❑ ❑ Automatic Time Switch 0 ❑ ❑ ❑ ❑ ❑ ❑ Automatic Daylighting 0 ❑ ❑ ❑ ❑ ❑ ❑ Demand Responsive 0 ❑ ❑ ❑ ❑ ❑ ❑ Outdoor Controls 0 ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-08122016-3995 Report Generated at: 2016-08-17 22:36:18 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV-MM Project Name Date Washington Park - Ulta Beauty 811712016 DESCRIPTION Building Envelope Measures: §110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §110.8(f): The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-13 between framing members. §110.7(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of §110.6(a): window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors (swinging and sliding),and 1.0 cfm/ft.2 for nonresidential double doors swin in . §110.6(a): Fenestration U-factor shall be rated in accordance with NFRC 100, or the applicable default U-factor. §110.6(a) : Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. §110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). EnergyPro 6. by EnergySoft User Number: 1064 ID: 1016 Page 21 of 22 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Washington Park - Ulta Beauty Date 8/17/2016 System Name RTU 1 thru 4 Floor Area 12,626 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 4 COIL CFM Total Room Loads 28,108 Return Vented Lighting Return Air Ducts Return Fan Ventilation 3,157 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 104,000 414,850 84,173 1,981 120,109 Total Output Btuh 416,000 0 Output Btuh/s ft 32.9 20,742 6,005 Cooling System 0 0 Output perSystem 118,000 124,297 27,510 3,157 147,477 Total Output Btuh 472,000 35,193 111,683 -35,193 Total Output Tons 39•3 1 20,742 6,005 Total Output Btuh/s ft 37.4 Total Output s ft/Ton 321.0 1 615,825 244,404 Air System CFM perSystem 4,000 HVAC EQUIPMENT SELECTION Airflow cfm 16,000 Lennox LGH120H4M(10 T) 389,778 52,500 416,000 Airflow cf nls ft 1.27 Airflow cfm/Ton 406.8 Outside Air % 19 7 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 389,778 52,500 416,000 Outside Air cfm/s ft 0.25 Note: values above given at ARI conditions r Jul 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperature! at Time of Heating Peak 26 OF No Outside Air 3,157 cfm 70 OF 63 OF 127 OF 127 OF Heating Coil Supply Fan 16,000 cfm 127 ° F ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 3,157 cfm 75 / 65 OF 85/68°F 59/58°F 59/58OF Cooling Coil Supply Fan 60 / 58 OF 16,000 cfm 60.5 % ROOM II_ll_II_ 74 / 65 OF EnergyPro 6. by EnergySoft User Number: 1064 ID: 1016 Page 22 of 22