Loading...
05-4134 (RC) Revision 1 Title 24TITLE 24 REPORT Title 24 Report for: PAPA DAN'S !79 41.0 HIGHWAY 111,. SUITE 112 LA QUINTA, CA 92253 � Qv�NE A QG0\4& SAFE D APcoNs-�Rvc c.lite—BY Project Designer: ROBERT RICCIARDI 75-090 ST CHARLES PL, STE A PALM DESERT, CA 92211 (760) 346-2223 Report Prepared By: JACK BENTSEN Bentsen/ Hui Engineering 70-141 Sun Valley Drive Rancho Mirage, CA 92270 (760) 324-7357 Job Number: 0555 Date: 10/21/2005 The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number. 0555 User Number: 6457 Vlr- �5 6177 - fr TITLE 24 REPORT Title 24 Report for: PAPA DAN'S !79 41.0 HIGHWAY 111,. SUITE 112 LA QUINTA, CA 92253 � Qv�NE A QG0\4& SAFE D APcoNs-�Rvc c.lite—BY Project Designer: ROBERT RICCIARDI 75-090 ST CHARLES PL, STE A PALM DESERT, CA 92211 (760) 346-2223 Report Prepared By: JACK BENTSEN Bentsen/ Hui Engineering 70-141 Sun Valley Drive Rancho Mirage, CA 92270 (760) 324-7357 Job Number: 0555 Date: 10/21/2005 The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number. 0555 User Number: 6457 Vlr- �5 6177 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C PROJECT NAME DATE • PAPA DAN'S 10/21/2005 PROJECT ADDRESS 79 410 HIGHWAY 111, SUITE 112 LA QUINTA PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit# BENTSEN/HUI ENGINEERING (760) 324-7357 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Bentsen/ Hui Engineering 760 324-7357 1 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 3, 735 Sq.FL 15 BUILDING TYPE 0 NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION 0 ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING Q AREA CATEGORY E] TAILORED F—]PERFORMANCECOMPLIANCE ❑ COMMON LIGHTING [STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE JACK BENTSEN The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146, 148 and 149 of Title 24, Part 6. Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE BENTSEN/HUI ENGINEERING LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included ®LTG -1-C, Parts 1 of 4 and 2 of 4:Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals ®LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed ®LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed ❑LTG -2-C: Interior Lighting Schedule ❑LTG -3-C: Portable Lighting Worksheet ❑LTG -4-C: Lighting Controls Credit Worksheet ❑LTG -5-C: Interior Lighting Power Allowance ❑LTG -6-C: Tailored Method Worksheet ❑LTG -7-C: Room Cavity Ratio Worksheet ❑LTG -8-C: Common Lighting Systems Method Worksheet ❑LTG -9-C: Line Voltage Track Lighting Worksheet EneMyPro 4.0 by Energysoft User Number: 6457 Job Number: 0555 Page:2 of 6 �ERTIFICATE OF COMPLIANCEj` (Part 2 of 4) LTG'1C PROJECT NAME DATE • PAPA DAN'S 1 10/21/2005 INSTALLED INTERIOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 3,364 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG.") 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 3,364 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INTERIOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -6-C) ALLOWED ❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -6-C) ALLOWED LIGHTING POWER C 4,482 IALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES lFrom LTG -5-C) 0 INTERIORMANDATORY G G AUTOMATIC CONTROUS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION EnergyPro 4.0 by EnergySoft NOTE TO FIELD CONTROL TYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if Daylighting NOTES TO FIELD - For Buildin De rtment Use Only EnergyPro 4.0 by EnergySoft User Number. 6457 Job Number. 0556 Page:3 of 6 �ERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1-C tOJECT NAME DATE • PAPA DAN'S 1 10/21/2005 CONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES CONTROL LOCATION CONTROL (Room # or Dwg. #) IDENTIFICATION CONTROL TYPE NOTE TO FIELD EnergyPro 4.0 by EnergySoft User Number: 6457 Job Number: 0556 PapeA of 6 �ERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1-C PROJECT NAME PAPA DAN'S DATE 10/21/2005 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) and Title 24 Part 6. Test Description Test Performed BY: ❑ LTG-2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.0 by EnergySoft User Number: 6457 Job Number: 0555 Page:5 of 6 INTERIOR LIGHTING POWER ALLOWANCE LTG -5-C PROJECT NAME PAPA DAN'S DATE 10/24/2005 ALLOWED(Choose COMPLETE BUILDING METHOD - CONDITIONED SPACES ALLOWED WATTS WATTS PER SF COMPLETE BLDG. AREA [!WATT:)0LOW BUILDING CATEGORY (From Section 146 Table 146-B) AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF Comp Bldg Restaurant 1.20 3,735 4,482 PAGE TOTAL BUILDING TOTAL AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTGd-C and LTG -6-C) 0 n 4. User Number. 6457 Job Number: 0655 Peoe:B of 9 PAGE TOTAL BUILDING TOTAL ' 3 735 3 735 4 482 4 482 AREA WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS (From LTG4-C or from computer run.) L �J UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 14643&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTGd-C and LTG -6-C) 0 n 4. User Number. 6457 Job Number: 0655 Peoe:B of 9 LIGHTING MANDATORY MEASURES LTG-MM PROJECT NAME DATE PAPA DAN'S 1 10/21/2005 DESCRIPTION Designer Enforcement F§ 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. a § 131(d)2 Override for Building Lighting Shutoff. The automatic building shutoff system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet F§ 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. o§ 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. a§ 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. a§ 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50°% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.0 by EnergySoft User Number. 6457 Job Number: 0555 Page:6 of 6