05-4134 (RC) Revision 1 Title 24TITLE 24 REPORT
Title 24 Report for:
PAPA DAN'S
!79 41.0 HIGHWAY 111,. SUITE 112
LA QUINTA, CA 92253
� Qv�NE A
QG0\4& SAFE D
APcoNs-�Rvc
c.lite—BY
Project Designer:
ROBERT RICCIARDI
75-090 ST CHARLES PL, STE A
PALM DESERT, CA 92211
(760) 346-2223
Report Prepared By:
JACK BENTSEN
Bentsen/ Hui Engineering
70-141 Sun Valley Drive
Rancho Mirage, CA 92270
(760) 324-7357
Job Number:
0555
Date:
10/21/2005
The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.0 by EnergySoft Job Number. 0555 User Number: 6457
Vlr- �5 6177
-
fr
TITLE 24 REPORT
Title 24 Report for:
PAPA DAN'S
!79 41.0 HIGHWAY 111,. SUITE 112
LA QUINTA, CA 92253
� Qv�NE A
QG0\4& SAFE D
APcoNs-�Rvc
c.lite—BY
Project Designer:
ROBERT RICCIARDI
75-090 ST CHARLES PL, STE A
PALM DESERT, CA 92211
(760) 346-2223
Report Prepared By:
JACK BENTSEN
Bentsen/ Hui Engineering
70-141 Sun Valley Drive
Rancho Mirage, CA 92270
(760) 324-7357
Job Number:
0555
Date:
10/21/2005
The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.0 by EnergySoft Job Number. 0555 User Number: 6457
Vlr- �5 6177
CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C
PROJECT NAME
DATE
• PAPA DAN'S
10/21/2005
PROJECT ADDRESS
79 410 HIGHWAY 111, SUITE 112 LA QUINTA
PRINCIPAL DESIGNER - LIGHTING
TELEPHONE
Building Permit#
BENTSEN/HUI ENGINEERING
(760) 324-7357
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
Bentsen/ Hui Engineering
760 324-7357
1 Enforcement Agency Use
GENERAL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
CLIMATE ZONE
3, 735 Sq.FL
15
BUILDING TYPE 0 NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM
❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS
PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION 0 ALTERATION
METHOD OF LIGHTING ❑ COMPLETE BUILDING Q AREA CATEGORY E] TAILORED F—]PERFORMANCECOMPLIANCE
❑ COMMON LIGHTING
[STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24,
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DOCUMENTATION AUTHOR
SIGNATURE
DATE
JACK BENTSEN
The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction
documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other
calculations submitted with this permit application. The proposed building has been designed to meet the lighting
requirements contained in Sections 110, 119, 130 through 132, and 146, 148 and 149 of Title 24, Part 6.
Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.)
❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this
document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer
or electrical engineer, or I am a licensed architect.
❑ 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or
6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing
this work.
❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code
Sections 5537, 5538 and 6737.1.
PRINCIPAL LIGHTING DESIGNER - NAME
SIGNATURE
DATE
BENTSEN/HUI ENGINEERING
LIGHTING MANDATORY MEASURES
Indicate location on plans of Note Block for Mandatory Measures
LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included
®LTG -1-C, Parts 1 of 4 and 2 of 4:Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals
®LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed
®LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed
❑LTG -2-C: Interior Lighting Schedule
❑LTG -3-C: Portable Lighting Worksheet
❑LTG -4-C: Lighting Controls Credit Worksheet
❑LTG -5-C: Interior Lighting Power Allowance
❑LTG -6-C: Tailored Method Worksheet
❑LTG -7-C: Room Cavity Ratio Worksheet
❑LTG -8-C: Common Lighting Systems Method Worksheet
❑LTG -9-C: Line Voltage Track Lighting Worksheet
EneMyPro 4.0 by Energysoft User Number: 6457 Job Number: 0555 Page:2 of 6
�ERTIFICATE OF COMPLIANCEj`
(Part 2 of 4) LTG'1C
PROJECT NAME DATE
• PAPA DAN'S 1 10/21/2005
INSTALLED INTERIOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
INSTALLED
WATTS
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 3,364
PORTABLE LIGHTING (From LTG -3-C) 0
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG.") 0
CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 3,364
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INTERIOR LIGHTING POWER FOR CONDITIONED SPACES
❑ COMPLETE BUILDING METHOD (From LTG -6-C) ALLOWED
❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS
❑ TAILORED METHOD (From LTG -6-C) ALLOWED LIGHTING POWER C 4,482
IALTERNATE COMPLIANCE
❑ PERFORMANCE METHOD
❑ COMMMON LIGHTING SYSTEM (From LTG -8-C)
ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES lFrom LTG -5-C) 0
INTERIORMANDATORY
G G AUTOMATIC CONTROUS
CONTROL LOCATION
(Room #)
CONTROL
IDENTIFICATION
EnergyPro 4.0 by EnergySoft
NOTE TO
FIELD
CONTROL TYPE
(Auto Time Switch, Dimming, etc.)
SPACE CONTROLLED
Check if
Daylighting
NOTES TO FIELD - For Buildin
De rtment Use Only
EnergyPro 4.0 by EnergySoft
User Number. 6457 Job Number. 0556 Page:3 of 6
�ERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1-C
tOJECT NAME DATE
• PAPA DAN'S 1 10/21/2005
CONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES
CONTROL LOCATION CONTROL
(Room # or Dwg. #) IDENTIFICATION
CONTROL TYPE
NOTE TO
FIELD
EnergyPro 4.0 by EnergySoft User Number: 6457 Job Number: 0556 PapeA of 6
�ERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1-C
PROJECT NAME
PAPA DAN'S
DATE
10/21/2005
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of §10-103(b) and Title 24 Part 6.
Test Description
Test Performed BY:
❑ LTG-2-A: Lighting Control Acceptance Document
- Occupancy Sensor Acceptance
- Manual Daylight Controls Acceptance
- Automatic Time Switch Control Acceptance
Equipment requiring acceptance testing
❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document
Equipment requiring acceptance testing
EnergyPro 4.0 by EnergySoft User Number: 6457 Job Number: 0555 Page:5 of 6
INTERIOR LIGHTING POWER ALLOWANCE LTG -5-C
PROJECT NAME
PAPA DAN'S
DATE
10/24/2005
ALLOWED(Choose
COMPLETE BUILDING METHOD - CONDITIONED SPACES
ALLOWED
WATTS
WATTS
PER SF
COMPLETE
BLDG. AREA
[!WATT:)0LOW
BUILDING CATEGORY (From Section 146 Table 146-B)
AREA CATEGORY METHOD - CONDITIONED SPACES
AREA
(SF)
ALLOWED
WATTS
AREA CATEGORY (From Section 146 Table 146-C)
WATTS
PER SF
Comp Bldg Restaurant
1.20
3,735
4,482
PAGE TOTAL
BUILDING TOTAL
AREA
WATTS
TAILORED METHOD - UNCONDITIONED SPACES
TOTAL UNCONDITIONED SPACES ALLOWED WATTS
(From LTGd-C and LTG -6-C) 0
n 4. User Number. 6457 Job Number: 0655 Peoe:B of 9
PAGE TOTAL
BUILDING TOTAL
'
3 735
3 735
4 482
4 482
AREA
WATTS
TAILORED METHOD - CONDITIONED SPACES
TOTAL ALLOWED WATTS
(From LTG4-C or from computer run.)
L �J
UNCONDITIONED SPACES
Complete Building and Area Catagory Methods
Category (From Section 146 Table 14643&C)
WATTS
PER SF
AREA
(SF)
ALLOWED
WATTS
PAGE TOTAL
BUILDING TOTAL
AREA
WATTS
TAILORED METHOD - UNCONDITIONED SPACES
TOTAL UNCONDITIONED SPACES ALLOWED WATTS
(From LTGd-C and LTG -6-C) 0
n 4. User Number. 6457 Job Number: 0655 Peoe:B of 9
LIGHTING MANDATORY MEASURES LTG-MM
PROJECT NAME DATE
PAPA DAN'S 1 10/21/2005
DESCRIPTION
Designer
Enforcement
F§ 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
a § 131(d)2 Override for Building Lighting Shutoff. The automatic building shutoff system is
provided with a manual, accessible override switch in sight of the lights. The area of
override is not to exceed 5,000 square feet
F§ 119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer.
o§ 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the
project are certified and listed in the Directory. All installed fixtures shall be certified.
§ 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp
fluorescent fixtures are tandem wired with two lamp ballasts where required by
Standards Section 132; or all one and three lamp fluorescent fixtures are specified
with electronic high -frequency ballasts and are exempt from tandem wiring
requirements.
a§ 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with
a separate switch or occupancy sensor device for each area with floor -to -ceiling
walls.
a§ 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight in the area shall have
50°% of the lamps in each daylit area controlled by a separate switch; or the effective
use of daylight cannot be accomplished because the windows are continuously
shaded by a building on the adjacent lot. Diagram of shading during different times
of the year is included on plans.
§ 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are
20 amps or less.
EnergyPro 4.0 by EnergySoft User Number. 6457 Job Number: 0555 Page:6 of 6