05-4134 (RC) Revision 2 Title 24I I. TITLE 24 REPORT I
Title 24 Report for:
Papa Dan's Italian Resturant
X7941-0-Hw_y 1:11�Suite,1y1=2�
La Quinta, CA 92253
Project Designer:
Robert H. Ricciardi Architect
75090 St. Charles Place #A
Palm Desert, CA 92211
760-346-2223
Report Prepared By:
Gina Rose
Eagle Quest Specialties, Inc.
42335 Washington Suite F #330
Palm Desert, CA 92211
(760) 345-4859 OF lA QU�pE A
SUI DING & SAFE
PPFOJED
FOR CONSTRU
�b
g� gY
DA
Job Number:
If ,
Date:
12/14/2005
he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
°' EnergyPro 4.0 by EnergySoft Job Number: User Number: 5862
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Nonresidential Performance Title 24 Forms 3
Form ENV -MM Envelope Mandatory Measures 11
Form LTG -MM Lighting Mandatory Measures 12
.Form MECH-MM Mechanical Mandatory Measures 13
Lighting Inspection Checklist 15
i
EnergyPro 4.0 by EnergySoft, Job Number: User Number: 5862
r-
L
4
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1
NAME
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
OROJECT
Papa Dan's Italian Resturant
DATE OF PLANS
12/14/2005
PROJECT ADDRESS
BUILDING CONDITIONED FLOOR AREA
4,120 Sq.Ft.
-
79410 Hwy 111 Suite 112 La Quinta
The Principal Designer hereby certifys that the proposed bul ding design represented in this set of construction docume s is
1
HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM
PRINCIPAL DESIGNER - ENVELOPE
TELEPHONE
Buildinn g P Perrmm it #
Robert H. Ricciardi Architect
760-346-2223
s
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
Eagle Quest Specialties, Inc.
(760) 345-4859
1 Enforcement Agency Use
GENERAL INFORMATION
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DATE OF PLANS
SIGNATUR
DATE
BUILDING CONDITIONED FLOOR AREA
4,120 Sq.Ft.
CLIMATE ZONE
15
BUILDING TYPE
The Principal Designer hereby certifys that the proposed bul ding design represented in this set of construction docume s is
NONRESIDENTIAL
HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM
PHASE OF CONSTRUCTION
❑
NEW CONSTRUCTION
ADDITION [:] ALTERATION EXISTING + ADDITION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DOCUMENTATION AUTHOR
SIGNATUR
DATE
Gina Rose
/A
` ��
I Z Y o
The Principal Designer hereby certifys that the proposed bul ding design represented in this set of construction docume s is
consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
'F
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, or I am a licensed architect.
❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
❑ F-] ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE 11
Indicate location on plans of Note Block for Mandatory M e
R Ir F E
PRINCIPAL ENVELOPE DESIGNER - NAME SIG C
Robert H. Ricciardi Architect d
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ighting Compliance Not In The Scope Of
LTIT[S—Sub-mittal
Required Forms
PRINCIPAL LIGHTING DESIGNER - NAME
SIGNATURE
LIC. NO.
DATE
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
MECH-1 MECH-2 MECH-3 MECH-5
Required Forms
RMECHANICAL DESIGNER - NAME
E
LIC. NO.
DATE
GR Rose CAD Design
�INCIPAL
n7 --. ���/�i'
- o s
z a
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:3 of 15 1
PERFORMANCE CERTIFICATE OFI COMPLIANCE Part2 of 3 PERF-'
WOJECT NAME DATE
Papa Dan's Italian Resturant 12/14/2005
Building Orientation
Number of Stories
Number of Systems
Number of Zones
E 90 d
Conditioned Floor Area
Unconditioned Floor Area
Conditioned Footp rint Area
Fuel Type
4,120
sgft.
sgft.
sgft.
.
1
0
B
4,120
1
Natural Gas
370
sgft.
Orientation Gross Area Glazing Area Glazing Ratio
'Front Elevation
E
637
sgft.
370
sgft.
Left -Elevation ''
(S):
589
sgft.
0
sqft:
0.0%
Rear Elevation'
W
637
sgft.
o
sgft.
0.0%
Right. Elevation ,
Total
Roof
(N)
589
2,452
4,120
sgft.
sgft.
sgft.
173
544
sgft.=29.4%
sgft.
sgft.
0.0%
Standard Proposed
Lighting Power Density 1.200 w/sgft. 1.200 w/sgft.
Prescriptive Env. Heat LOSS 656 Btu/h 675 Btu/h
Prescriptive Env. Heat Gain 70,446 Btu/h-F 88,728 Btu/h-F
Remarks:
Standard Building (Compliance)
Run nnuauvn i irne:-icnwruD -1sa0:4a Kul
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number:
7 75
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
V OJECT NAME
Papa Dan's Italian Resturant
DATE
12/14/2005
ZONE INFORMATION
System Name
Floor Inst.
Area LPD
Zone Name Occupancy Type (sqft.) (W/sf)1
Ctrl. Allowed LPD
Credits Area Tailored
(W/S02 W/s 3 W/s 4
I Proc.
Loads
(WISO
Resturant
Resturant Comp Bldg Restaurant 4,120 '1.20
Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C
(items marked with asterisk, see LTG -2 -C by others) (by others)
Items above require special documentation
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
Not Valid for permit applications submitted on or after 01/23/06 because Energy Budget is based on SEER 10.
The HVAC System "Resturant' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the MECH-5-A.
The HVAC System 'Resturant' includes Demand Control Ventilation per Standards Section 121.
The Zone 'Resturant' has a North/East/South Display Perimeter Credit of 191 ft.
The Zone 'Resturant' has a West Display Perimeter Credit of 67 ft.
I ne excepuonai features ustea m tms performance approach application have specifically been reviewed. Adequate written justification and
�cumentation for their use have been provided by the applicant.
Authorized Signature or Stamp
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:5 of 15
CERTIFICATE OF COMPLIANCE ENV -1 -C
OJECT NAME DATE
t Papa Dan's Italian Resturant 12/14/2005
OPAQUE SURFACES
More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors
from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building managers office after construction
#
Surface
Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Am.
A.
Tilt
Cond'
Status
Joint Appendix
IV Reference
Location / Comments
1
Roof
4,120
0.036
R-30
R-0.0
0
0
New
02-A9
Resturant
2
Wall
416
0.074
R-19
R-0.0
0
90
Existin
09-A5
Resturant
3
Wall
266
0.074
R-19
R-0.0
90
90
Existing
09-A5
Resturant
4
Wall
589
0.074
R-19
R-0.0
180
90
Existing
09-A5
Resturant
5
Wall
595
0.074
R-19
R-0.01
270
90
Existing
09-A5
Resturant
6
Door
21
0.700
None
R-0.0
270
90
Existing
28-A2
Resturant
7
Door
21
0.700
None
R-0.0
270
90
Existin
28-A2
Resturant
More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors
from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building managers office after construction
#
T _pe
# Exterior Shade Type
Window Overhang Left Fin Right Fin
SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len.-Hgt. Dist. Len. H t.
Area U -Fac'
SHGC2
Act.
Am.
Cond.
Stat.
Glazing Tye
Location/
Comments
4 None
Window
Right
(N)
58 0.7101116-A
0.60
116-B
0
Existing_Double
Metal Tinted
Resturant
Window
Right (N)
58 0.710 116-A
0.60
116-B
0
Existing
Double Metal Tinted
Resturant
3
Window
Right
N
58 0.710 116-A
0.60
116-B
0
Existing
Double Metal Tinted
Resturant
4
Window
Front
E
124 0.710 116-A
0.60
116-B
90
Existing
Double Metal Tinted
Resturant
-5
Window
Front
E
124 0.710 116-A
0.60
116-B
90
Existing
Double Metal Tinted
Resturant
6
Window
Front
(E)
42 0.770 116-A
0.59
116 -BI
90
Existing
Double Metal Tinted (DOOR)
Resturant
7
Window
Front
E
82 0.710 116-A
0.60
116-B
90
Existing
Double Metal Tinted
Resturant
(1)U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
(2) SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
# Exterior Shade Type
Window Overhang Left Fin Right Fin
SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len.-Hgt. Dist. Len. H t.
1 None
0.76
2 None
0.76
3 None
0.76
4 None
0.76
5 None '
0.76
6 None
0.76
7 None
0.76
INIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
The
0.61
ed building contains an enclosed space with floor area greater than 26,000 sq.ft, a calling height greater than 15 feet and a LPD for general lighting of at least
If this box Is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach.
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number Page: 6 of 15
CERTIFICATE OF COMPLIANCE MECH-1-C
lROJECT NAME DATE
Papa Dan's Italian Resturant 12/14/2005
4
4
ueslgner:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6.
STATEMENT OF COMPLIANCE ..
❑ MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
�] MECH-4-A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction inspection.
❑ MECH-5-A: Air Distribution Acceptance Document
Equipment requiring acceptance testing
This test required If the unit serves 5,000 R2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an
attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
❑ MECH-6-A: Demand Control Ventilation Acceptance Document
Equipment requiring acceptance testing
All new DCV controls installed on new or existing packaged systems must be tested.
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VA fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A: -Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hot water systems.
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr.
-Water-loop Heat Pump Controls
Applies to all new waterioop heat pump systems where the combined loop pumps are greater than 5 hp.
-Variable Frequency Controls Applies to all new distribution pumps on new variable Bow chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:7 of 15
IR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
F OJECT NAME DATE
Papa Dan's Italian Resturant 12/14/2005
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
MANDATORY MEASURES
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
4ipe Insulation
uct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
T-24
Section
AIR SYSTEMS, Central or Single Zone
Resturant
3
Reference on Plans or Specification 1
112(a)
3.30 COP
112(a_
10.3 EER
112(b)
Yes
112(c), 115(a)
n/a
121(b)
Yes
121(b)
2207 cfm
121 c
No
121(c)
Yes
121(p) 1, 22(e)
Programmable Switch
122(e)
Heating & Cooling Required
122(D,
Auto
122(g)
n/a
123
124
R-8.0
144 (a & b)
n/a
144 a & b
159,266 btuh
144 a & b
n/a
144 a & b
180,524 btuh
144 c
Constant Volume
144 (c)
144 c
Yes
144 d
No
144 a
Fixed TemInte rated
144
Constant Tem
144 (f)
Constant Temp
144 (k)
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:8 of 15
U
M
PI
iE�
W
Q
z
H
U
W
rIW
M
CL
Z
Transfer Air
0
Design Min. Ai
o
rn
Q
Setpoint
L
Wv
m
a.
w c
g
Max of
°
m
Columns H, J,
m
w a0i
>m
M
K or 300 CFM
z
�
2
Bx0.4
H
�O
C —
>
Q
Y
CFM/sq. ft
a
m
U) Q
>
x
c
W H
mag
30% of Design
t
Zone Supply
CFM
8
m
Design
o
o
M
N
o
o
—
Vent Air
CN
CFM
C14
04E
N
o
8
REQ'D V.A
m
co
=
Max of
N
m
8 E
(D or G)
_
a
N
Min CFM
m
o
a
E
a
Q
c9
by Occupant
E
z'
m
(Ex F)�o
��
8
o
V
CFM
m
o
Z
m
Q
LL
per
U
x
m E
Person erson
U
a
N
=_ E
v
w
Number ofo
d
0
O
People
o
m a
m
o
E
a o
do
O1m
Min CFM
m
t
= a
p
by Area
LQ
E^
w
m
N
(BXC)E
c
_
c
00�
co
2
c
o
E
mU
o
E
ag
a
per
m
E
N
a
Square Foot
> _'
i
16
C` Q
w
a
m
m
=��
Z
w
E
E
o
N
c O
Q
Condition
@
o a
m
m
m
rn
m,
D
N
«.M
Area
Ni
v
a
m c
m
(SF)
N
`o E
E
Z
t
o
M
.O
°
S
O
m m
LL°
N
C
Q
In �O
m m
m
W
U'iiY
m
om
ii
mm
v
O
!n
J
m
m
LL
x=
o
'oo a
rn
Z
W
O L
N ELLI
L..
a
LL
>E
Q
= o
d
m
m
E v
d
Q
O
o
m
i
c
o c >>
m...
o
p
2
V
N
D
-_ a'
a
'-
E
c 'x
E
g
c
(L
Z
m
ir
0
U
m
Q
c
f
f
r
Er
w
_
�
c
w
L)
N
W
= —
Y
Z
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
Papa Dan's Italian Resturant
TANK INSUL.
DATE
12/14/2005
CHILLER AND TOWER SUMMARY
Distribution Type
Qty
Efficiency
Tons
PUMPS
Ext.
R -Val.
Efficlencv
Equipment Name
Equipment Type
Qty.
Tot.
Qty
GPM
BHP
Motor
Eff.
Drive
Eff.
Pump
Control
88,000
10.3 EER
Existing
Fixed Temp (Integrate
MULTI -FAMILY CENTRAL WATER HEATING DETAILS
Hot Water P mp
Hot Water Piping Length ft
Control
#
HP
Type
In Plenum
Outside
Buried
Add 1/2"
Insulation
DBOILER
NTRAL SYSTEM RATINGS
Energy
Factor
or RE
Standby
Loss or
Pilot
TANK INSUL.
System Name
System Type
Distribution Type
Qty
Rated
Input
Vol.
(Gals.)
Condition
Status
Ext.
R -Val.
Efficlencv
Condition
Status
Economizer Type
(5/6)2 CARRIER 50HJ0008---
Packaged DX
3
85,000
0 0.0
3.30 COP
88,000
10.3 EER
Existing
Fixed Temp (Integrate
MULTI -FAMILY CENTRAL WATER HEATING DETAILS
Hot Water P mp
Hot Water Piping Length ft
Control
#
HP
Type
In Plenum
Outside
Buried
Add 1/2"
Insulation
NTRAL SYSTEM RATINGS
HEATING
COOLING
System Name
S stem Type
Qty
Outpint
Aux.
kW
Eff.
Output
Efficlencv
Condition
Status
Economizer Type
(5/6)2 CARRIER 50HJ0008---
Packaged DX
3
85,000
0 0.0
3.30 COP
88,000
10.3 EER
Existing
Fixed Temp (Integrate
CENTRAL SYSTEM FAN SUMMARY
PPL
FAN
RET RN
FAN
System Name
Fan T _ e
Motor Location
CFM
BHP
Motor
Eff.
Drive
Eff.
CFM
BHP
Motor
Eff.
Drive
Eff.
CARRIER 50HJ0008---
(5/6)2
Constant Volume
Draw -Through
3,000
0.00
40.0%
97.0%
none
•
Run Initiation Time: 12/14/05 13:35:43 Run Code: 1134596143
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number Page 10 of 15
4
4
ENVELOPE MANDATORY MEASURES . ENV -MM
NAME
Papa Dan's Italian Resturant
DATE
. 12/14/2005
DESCRIPTION
Designer
Enforcement
0 §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply
with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3.
F§118(c) All Insulating Materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
XJ §117(a) All Exterior Joints and openings in the building that are observable sources of air
leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
FX § 116(b) Site Coristructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors and
fire doors).
o§ 116(a)1 Manufactured Doors and Windows installed shall have air Infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
' fenestration products must be labeled for U -value according to NFRC procedures.
R §118(,) Demising Walls In Nonresidential Buildings:
The opaque portions of framed demising walls in nonresidential buildings shall have
Insulation with an installed R -value of no less than R-13 between framing members.
EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 15
4
4
LIGHTING MANDATORY MEASURES LTG -MM
NAME
'Dan's Italian Resturant
DATE
12/14/2005
DESCRIPTION
Desi ner
Enforcement
❑X § 131(d)1 For every floor, all Interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
XJ § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system Is
provided with a manual, accessible override switch in sight of the lights. The area of
override Is not to exceed 5,000 square feet.
X] § 119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer.
X❑ § 111 • Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the
project are certified and listed in the Directory. All installed fixtures shall be certified.
❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp
fluorescent fixtures are tandem wired with two lamp ballasts where required by
Standards Section 132; or all one and three lamp fluorescent fixtures are specified
with electronic high -frequency ballasts and are exempt from tandem wiring
requirements.
§ 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with
In a separate switch or occupancy sensor device for each area with floor -to -ceiling
walls.
§ 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
0 § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight In the area shall have
50% of the lamps in each daylit area controlled by a separate switch; or the effective
use of daylight cannot be accomplished because the windows are continuously
shaded by a building on the adjacent lot. Diagram of shading during different times
of the year is Included on plans.
❑ § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are
20 amps or less.
EnergyPro 4.0 by Energysoft User Number: 5862 Job Number: Page: 12 of 15
MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM
OJECT NAME DATE
Papa Dan's Italian Resturant 12/14/2005
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
❑X §111 Any appliance for which there is a California standard established in the
Appliance Efficiency Regulations will comply with the applicable standard.
X] § 115(a) Fan type central furnaces shall not have a pilot light.
X] § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
Standards Section 123.
§ 124 Air handling duct systems shall be installed and insulated in compliance with
Sections 601, 603 and 604 of the Uniform Mechanical Code.
Controls
§ 122(e) Each space conditioning system shall be installed with one of the following:
X] § 122(e)1A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the
requirements of Section 112 (d)) shall be installed with an automatic time switch
with an accessible manual override that allows operation of the system during
off -hours for up to 4 hours. The time switch shall be capable of programming
different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at
least 10 hours if power is interrupted; or
❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or
§ 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of
the system.
n§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint.
❑ § 122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with
isolation zones. Each zone: shall not exceed 25,000 square feet; shall be
provided with isolation devices, such as valves or dampers, that allow the supply
of heating or cooling to be setback or shut off independently of other isolation
areas; and shall be controlled by a time control device as described above.
® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat
• that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the
control shall be adjustable up to 85 degrees F or higher. Where used for both
heating and cooling, the control shall be capable of providing a deadband of at
least 5 degrees F within which the supply of heating and cooling is shut off or
reduced to a minimum.
§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and
adjustable setpoint stops accessible only to authorized personnel.
§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance
supplementary heater operation when the heating load can be met by the heat
pump alone.
EnergyPro By EnergySoft User Number: User Job Number: Page: 13 of 15
4
4
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
ECT NAMEDATE
Paga Dan's Italian Resturant I
12/14/2005
Description
Designer
Enforcement
Ventilation
§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at
the ventilation rates as specified on these plans.
FX] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers in all openings to the outside, except for combustion air
openings.
❑ § 121(f)1. Air Balancing: The system shall be balanced in accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
X❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
Installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the ventilation system; or
❑ § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
basis and displaying that quantity on a readily accessible display divice; or
§ 121(04 Another method approved by the Commission.
Service Water Heating Systems
X❑ § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of
automatically turning off the circulating pump(s) when hot water is not required.
0 § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the
outlet temperature to 110 degrees F.
X] § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the
following:
Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per
minute.
Foot actuated control valves, and outlet devices that limit the flow of hot water to a
maximum of 0.75 gallons per minute. '
Proximity sensor actuated control valves, and outlet devices that limit the flow of hot
water to a maximum of 0.75 gallons per minute.
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor
controls).
EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 15
LIGHTING INSPECTION CHECKLIST LTG -I
OJECT NAME INSPECTION DATE
Papa Dan's Italian Resturant 1 12/14/2005
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page: 15 of 15
FIXTURE
LAMP
LAMP
NUMBER OF
WATTS PER
CODE
TYPE
DESCRIPTION
TYPE
QUANT.
FIXTURES
FIXTURE
FIELD NOTES
EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page: 15 of 15