05-4134 (RC) Revision 2 Title 24I I. TITLE 24 REPORT I Title 24 Report for: Papa Dan's Italian Resturant X7941-0-Hw_y 1:11�Suite,1y1=2� La Quinta, CA 92253 Project Designer: Robert H. Ricciardi Architect 75090 St. Charles Place #A Palm Desert, CA 92211 760-346-2223 Report Prepared By: Gina Rose Eagle Quest Specialties, Inc. 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 OF lA QU�pE A SUI DING & SAFE PPFOJED FOR CONSTRU �b g� gY DA Job Number: If , Date: 12/14/2005 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. °' EnergyPro 4.0 by EnergySoft Job Number: User Number: 5862 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 11 Form LTG -MM Lighting Mandatory Measures 12 .Form MECH-MM Mechanical Mandatory Measures 13 Lighting Inspection Checklist 15 i EnergyPro 4.0 by EnergySoft, Job Number: User Number: 5862 r- L 4 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE OROJECT Papa Dan's Italian Resturant DATE OF PLANS 12/14/2005 PROJECT ADDRESS BUILDING CONDITIONED FLOOR AREA 4,120 Sq.Ft. - 79410 Hwy 111 Suite 112 La Quinta The Principal Designer hereby certifys that the proposed bul ding design represented in this set of construction docume s is 1 HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Buildinn g P Perrmm it # Robert H. Ricciardi Architect 760-346-2223 s DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Eagle Quest Specialties, Inc. (760) 345-4859 1 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DATE OF PLANS SIGNATUR DATE BUILDING CONDITIONED FLOOR AREA 4,120 Sq.Ft. CLIMATE ZONE 15 BUILDING TYPE The Principal Designer hereby certifys that the proposed bul ding design represented in this set of construction docume s is NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ADDITION [:] ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATUR DATE Gina Rose /A ` �� I Z Y o The Principal Designer hereby certifys that the proposed bul ding design represented in this set of construction docume s is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to 'F sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ F-] ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE 11 Indicate location on plans of Note Block for Mandatory M e R Ir F E PRINCIPAL ENVELOPE DESIGNER - NAME SIG C Robert H. Ricciardi Architect d LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ighting Compliance Not In The Scope Of LTIT[S—Sub-mittal Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms RMECHANICAL DESIGNER - NAME E LIC. NO. DATE GR Rose CAD Design �INCIPAL n7 --. ���/�i' - o s z a EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:3 of 15 1 PERFORMANCE CERTIFICATE OFI COMPLIANCE Part2 of 3 PERF-' WOJECT NAME DATE Papa Dan's Italian Resturant 12/14/2005 Building Orientation Number of Stories Number of Systems Number of Zones E 90 d Conditioned Floor Area Unconditioned Floor Area Conditioned Footp rint Area Fuel Type 4,120 sgft. sgft. sgft. . 1 0 B 4,120 1 Natural Gas 370 sgft. Orientation Gross Area Glazing Area Glazing Ratio 'Front Elevation E 637 sgft. 370 sgft. Left -Elevation '' (S): 589 sgft. 0 sqft: 0.0% Rear Elevation' W 637 sgft. o sgft. 0.0% Right. Elevation , Total Roof (N) 589 2,452 4,120 sgft. sgft. sgft. 173 544 sgft.=29.4% sgft. sgft. 0.0% Standard Proposed Lighting Power Density 1.200 w/sgft. 1.200 w/sgft. Prescriptive Env. Heat LOSS 656 Btu/h 675 Btu/h Prescriptive Env. Heat Gain 70,446 Btu/h-F 88,728 Btu/h-F Remarks: Standard Building (Compliance) Run nnuauvn i irne:-icnwruD -1sa0:4a Kul EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: 7 75 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 V OJECT NAME Papa Dan's Italian Resturant DATE 12/14/2005 ZONE INFORMATION System Name Floor Inst. Area LPD Zone Name Occupancy Type (sqft.) (W/sf)1 Ctrl. Allowed LPD Credits Area Tailored (W/S02 W/s 3 W/s 4 I Proc. Loads (WISO Resturant Resturant Comp Bldg Restaurant 4,120 '1.20 Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C (items marked with asterisk, see LTG -2 -C by others) (by others) Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Not Valid for permit applications submitted on or after 01/23/06 because Energy Budget is based on SEER 10. The HVAC System "Resturant' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the MECH-5-A. The HVAC System 'Resturant' includes Demand Control Ventilation per Standards Section 121. The Zone 'Resturant' has a North/East/South Display Perimeter Credit of 191 ft. The Zone 'Resturant' has a West Display Perimeter Credit of 67 ft. I ne excepuonai features ustea m tms performance approach application have specifically been reviewed. Adequate written justification and �cumentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:5 of 15 CERTIFICATE OF COMPLIANCE ENV -1 -C OJECT NAME DATE t Papa Dan's Italian Resturant 12/14/2005 OPAQUE SURFACES More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building managers office after construction # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. A. Tilt Cond' Status Joint Appendix IV Reference Location / Comments 1 Roof 4,120 0.036 R-30 R-0.0 0 0 New 02-A9 Resturant 2 Wall 416 0.074 R-19 R-0.0 0 90 Existin 09-A5 Resturant 3 Wall 266 0.074 R-19 R-0.0 90 90 Existing 09-A5 Resturant 4 Wall 589 0.074 R-19 R-0.0 180 90 Existing 09-A5 Resturant 5 Wall 595 0.074 R-19 R-0.01 270 90 Existing 09-A5 Resturant 6 Door 21 0.700 None R-0.0 270 90 Existing 28-A2 Resturant 7 Door 21 0.700 None R-0.0 270 90 Existin 28-A2 Resturant More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building managers office after construction # T _pe # Exterior Shade Type Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len.-Hgt. Dist. Len. H t. Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Tye Location/ Comments 4 None Window Right (N) 58 0.7101116-A 0.60 116-B 0 Existing_Double Metal Tinted Resturant Window Right (N) 58 0.710 116-A 0.60 116-B 0 Existing Double Metal Tinted Resturant 3 Window Right N 58 0.710 116-A 0.60 116-B 0 Existing Double Metal Tinted Resturant 4 Window Front E 124 0.710 116-A 0.60 116-B 90 Existing Double Metal Tinted Resturant -5 Window Front E 124 0.710 116-A 0.60 116-B 90 Existing Double Metal Tinted Resturant 6 Window Front (E) 42 0.770 116-A 0.59 116 -BI 90 Existing Double Metal Tinted (DOOR) Resturant 7 Window Front E 82 0.710 116-A 0.60 116-B 90 Existing Double Metal Tinted Resturant (1)U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len.-Hgt. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 5 None ' 0.76 6 None 0.76 7 None 0.76 INIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The 0.61 ed building contains an enclosed space with floor area greater than 26,000 sq.ft, a calling height greater than 15 feet and a LPD for general lighting of at least If this box Is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach. EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number Page: 6 of 15 CERTIFICATE OF COMPLIANCE MECH-1-C lROJECT NAME DATE Papa Dan's Italian Resturant 12/14/2005 4 4 ueslgner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE .. ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. �] MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 R2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new waterioop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable Bow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:7 of 15 IR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C F OJECT NAME DATE Papa Dan's Italian Resturant 12/14/2005 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones 4ipe Insulation uct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance T-24 Section AIR SYSTEMS, Central or Single Zone Resturant 3 Reference on Plans or Specification 1 112(a) 3.30 COP 112(a_ 10.3 EER 112(b) Yes 112(c), 115(a) n/a 121(b) Yes 121(b) 2207 cfm 121 c No 121(c) Yes 121(p) 1, 22(e) Programmable Switch 122(e) Heating & Cooling Required 122(D, Auto 122(g) n/a 123 124 R-8.0 144 (a & b) n/a 144 a & b 159,266 btuh 144 a & b n/a 144 a & b 180,524 btuh 144 c Constant Volume 144 (c) 144 c Yes 144 d No 144 a Fixed TemInte rated 144 Constant Tem 144 (f) Constant Temp 144 (k) No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page:8 of 15 U M PI iE� W Q z H U W rIW M CL Z Transfer Air 0 Design Min. Ai o rn Q Setpoint L Wv m a. w c g Max of ° m Columns H, J, m w a0i >m M K or 300 CFM z � 2 Bx0.4 H �O C — > Q Y CFM/sq. ft a m U) Q > x c W H mag 30% of Design t Zone Supply CFM 8 m Design o o M N o o — Vent Air CN CFM C14 04E N o 8 REQ'D V.A m co = Max of N m 8 E (D or G) _ a N Min CFM m o a E a Q c9 by Occupant E z' m (Ex F)�o �� 8 o V CFM m o Z m Q LL per U x m E Person erson U a N =_ E v w Number ofo d 0 O People o m a m o E a o do O1m Min CFM m t = a p by Area LQ E^ w m N (BXC)E c _ c 00� co 2 c o E mU o E ag a per m E N a Square Foot > _' i 16 C` Q w a m m =�� Z w E E o N c O Q Condition @ o a m m m rn m, D N «.M Area Ni v a m c m (SF) N `o E E Z t o M .O ° S O m m LL° N C Q In �O m m m W U'iiY m om ii mm v O !n J m m LL x= o 'oo a rn Z W O L N ELLI L.. a LL >E Q = o d m m E v d Q O o m i c o c >> m... o p 2 V N D -_ a' a '- E c 'x E g c (L Z m ir 0 U m Q c f f r Er w _ � c w L) N W = — Y Z MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Papa Dan's Italian Resturant TANK INSUL. DATE 12/14/2005 CHILLER AND TOWER SUMMARY Distribution Type Qty Efficiency Tons PUMPS Ext. R -Val. Efficlencv Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 88,000 10.3 EER Existing Fixed Temp (Integrate MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Length ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation DBOILER NTRAL SYSTEM RATINGS Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. Efficlencv Condition Status Economizer Type (5/6)2 CARRIER 50HJ0008--- Packaged DX 3 85,000 0 0.0 3.30 COP 88,000 10.3 EER Existing Fixed Temp (Integrate MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Length ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation NTRAL SYSTEM RATINGS HEATING COOLING System Name S stem Type Qty Outpint Aux. kW Eff. Output Efficlencv Condition Status Economizer Type (5/6)2 CARRIER 50HJ0008--- Packaged DX 3 85,000 0 0.0 3.30 COP 88,000 10.3 EER Existing Fixed Temp (Integrate CENTRAL SYSTEM FAN SUMMARY PPL FAN RET RN FAN System Name Fan T _ e Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. CARRIER 50HJ0008--- (5/6)2 Constant Volume Draw -Through 3,000 0.00 40.0% 97.0% none • Run Initiation Time: 12/14/05 13:35:43 Run Code: 1134596143 EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number Page 10 of 15 4 4 ENVELOPE MANDATORY MEASURES . ENV -MM NAME Papa Dan's Italian Resturant DATE . 12/14/2005 DESCRIPTION Designer Enforcement 0 §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. F§118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. XJ §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. FX § 116(b) Site Coristructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). o§ 116(a)1 Manufactured Doors and Windows installed shall have air Infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured ' fenestration products must be labeled for U -value according to NFRC procedures. R §118(,) Demising Walls In Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have Insulation with an installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 15 4 4 LIGHTING MANDATORY MEASURES LTG -MM NAME 'Dan's Italian Resturant DATE 12/14/2005 DESCRIPTION Desi ner Enforcement ❑X § 131(d)1 For every floor, all Interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. XJ § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system Is provided with a manual, accessible override switch in sight of the lights. The area of override Is not to exceed 5,000 square feet. X] § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. X❑ § 111 • Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. ❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with In a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. 0 § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight In the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is Included on plans. ❑ § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.0 by Energysoft User Number: 5862 Job Number: Page: 12 of 15 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM OJECT NAME DATE Papa Dan's Italian Resturant 12/14/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. X] § 115(a) Fan type central furnaces shall not have a pilot light. X] § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. n§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. ❑ § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat • that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: Page: 13 of 15 4 4 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM ECT NAMEDATE Paga Dan's Italian Resturant I 12/14/2005 Description Designer Enforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. FX] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ § 121(f)1. Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or X❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑ § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(04 Another method approved by the Commission. Service Water Heating Systems X❑ § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. 0 § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X] § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. ' Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 15 LIGHTING INSPECTION CHECKLIST LTG -I OJECT NAME INSPECTION DATE Papa Dan's Italian Resturant 1 12/14/2005 EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page: 15 of 15 FIXTURE LAMP LAMP NUMBER OF WATTS PER CODE TYPE DESCRIPTION TYPE QUANT. FIXTURES FIXTURE FIELD NOTES EnergyPro 4.0 by EnergySoft User Number: 5862 Job Number: Page: 15 of 15