BRES2018-0335 Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Ratpack Residence 53-525 Humbolt Blvd. La Quinta, CA 92253 Project Designer: Gordon Stein 55-053 Sorrel Court Indio, CA 92201 (760) 773-4488 Report Prepared by: CITy oF LA Q�ION A 13UILDINGr DIVISION REVIEWED FOR CODE COMPLIANCE DATE LIE i l� r By Tim Scott Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #8 Palm Desert, CA 92260 (760) 200-4780 Job Number: Date: 12/19/2018 RE "DIVED DEC 2 12018 CITY OF LA QUANTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software —www.energysoft.com C1T� I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 16 Form MF-1 R Mandatory Measures Summary 23 HVAC System Heating and Cooling Loads Summary 27 Room Load Summary 33 Room Heating Peak Loads 39 Room Cooling Peak Loads 46 CERT' XTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD Project Name: Ratpack Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Ratpack Remodel-Stein-18.ribd16x Cf ''RF-01 Page 1 of 13 GENERAL INFORMATION 01 Project Name Ratpack 02 Calculation Description Title 24 Analysis 03 Project Location 53-525 Humbolt Blvd. 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 8550 15 Number of Zones 7 16 Slab Area (ft) 8550 17 Number of Stories 1 18 Addition Cond. Floor Area (ft) 0 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 41.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 7.10 7.11 -0.01 -0.1 % Space Cooling 121.46 121.09 0.37 0.3% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 3.38 3.38 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 ---- Compliance Energy Total 131.94 131.58 0.36 0.3% Registration Number: 219-Po10266171C-000-000-00o0o00-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERT! \TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE "HOD CF 'RF-01 Project Name: Ratpack Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Page 2 of 13 Calculation Description: Title 24 Analysis Input File Name: Ratpack Remodel-Stein-18.ribd16x REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins • Exposed slab floor in conditioned zone • Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Refrigerant Charge verification required if a refrigerant containing component is altered • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Duct Sealing required if a duct system component, plenum, or air handling unit is altered • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Ratpack 8550 1 6 7 0 1 Registration Number: 218-P010266171C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERT' NTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD Project Name: Ratpack Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Calculation Description; Title 24 Analysis Input File Name: Ratpack Remodel-Stein-18Abd16x Cl PRF-01 Page 3 of 13 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Suite 1 Conditioned HVAC 1 mstrl 862 10.2 DHW Sys 1 n/a great room Conditioned HVAC 2, 3 & 42 3995 12.1 DHW Sys 1 n/a 2 Conditioned HVAC 5 & 63 662 10 DHW Sys 1 n/a 3 Conditioned HVAC 5 & 63 662 10 DHW Sys 1 n/a guest-4 Conditioned HVAC 64 753 10 DHW Sys 1 n/a Cart Garage Zone Conditioned HVAC 85 562 10 DHW Sys 1 n/a 2 Car Garage -Renovation Conditioned HVAC 7 & 86 1054 10 DHW Sys 1 n/a Registration Number: 218-P010266171C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERT' \TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD Project Name: Ratpack Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Ratpack Remodel-Stein-18.ribdl6x Cr 'RF-01 Page 4 of 13 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ftZ) Tilt (deg) Wall Exception Status Verified Existing Condition 80d Wall Suite 1 R-21 Wall (W21.2x6.16) 80 Front 150 0 90 n/a Existing No 170d Wall Suite 1 R-21 Wall (W.21.2x6.16) 170 Left 720 125.8 90 n/a Existing No 260d Wall Suite 1 R-21 Wall (W21.2x6.16) 260 Back 440 133 90 n/a Existing No 350d Wall Suite 1 R-21 Wall (W21.2x6.16) 350 Right 900 106.2 90 n/a Existing No Interior Surface Suite 1 —great room R-0 Interior Wall 424 0 n/a Existing No Roof R-38 Suite 1 R-38 + R13 Roof Attic 862 n/a Existing No 80d Wall 2 great room R-21 Wall (W21.2x6.16) 80 Front 1056 575.6 90 n/a Existing No 170d Wall 2 great room R-21 Wall (W21.2x6.16) 170 Left 575 511.055 90 n/a Existing No 260d Wall 2 great room R-21 Wall (W21.2x6.16) 260 Back 952 715.863 90 n/a Existing No 350d Wall 2 great room R-21 Wall (W21.2x6.16) 350 Right 432 272.3 90 n/a Existing No Interior Surface 2 great room»Suite 1 1 R-0 Interior Wall 424 0 n/a Existing No Roof R-38 2 great room R-38 + R13 Roof Attic 3995 n/a Existing No 170d Wall 3 2 R-21 Wall (W21.2x6.16) 170 Left 230 108.2 90 n/a Existing No 260d Wall 3 2 R-21 Wall (W21.2x6.16) 260 Back 320 108 90 n/a Existing No 350d Wall 3 2 R-21 Wall (W21.2x6.16) 350 Right 230 88 90 n/a Existing No Interior Surface 3 2»3 R-0 Interior Wall 230 0 n/a Existing No Roof R-38 3 2 R-38 + R13 Roof Attic 662 n/a Existing No 80d Wall 3 3 R-21 Wall (W.21.2x6.16) 80 Front 320 88 90 n/a Existing No 170d Wall 4 3 R-21 Wall (W21.2x6.16) 170 Left 230 108.173 90 n/a Existing No 350d Wall 4 3 R-21 Wall (W21.2x6.16) 350 Right 230 88 90 n/a Existing No Interior Surface 4 3»2 R-0 Interior Wall 230 0 n/a Existing No Roof R-38 4 3 R-38 + R13 Roof Attic 662 n/a Existing No 80d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 80 Front 200 0 90 n/a Existing No 170d Wall 5 guest-4 R-21 Wall (W21.2x6.16) 170 Left 330 110.2 90 n/a Existing No 260d Wall 4 guest-4 R-21 Wall (W21.2x6.16) 260 Back 200 88.021 90 n/a Existing No 350d Wall 5 guest-4 R-21 Wall (W.21.2x6.16) 350 Right 330 77.988 90 n/a Existing No Interior Surface 5 guest-4>>3 R-0 Interior Wall 124 0 n/a Existing No Roof R-38 5 guest-4 R-38 + R13 Roof Attic 753 1 n/a Existing No Registration Number: 218-P010266171C-000-000-0000000-0000 Registration DateMme: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERT' \TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Ratpack Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-18.ribdl6x CF 'RF-01 Page 5 of 13 80d Wall 5 Cart Garage Zone R-21 Wall (W21.2x6.16) 80 Front 190 0 90 n/a Existing No 170d Wall 6 Cart Garage Zone R-21 Wall (W21.2x6.16) 170 Left 35 0 90 n/a Existing No 260d Wall 5 Cart Garage Zone R-21 Wall (W.21.2x6.16) 260 Back 350 110.4 90 n/a Existing No 350d Wall 6 Cart Garage Zone R-21 Wall (W21.2x6.16) 350 Right 278 78.4 90 n/a Existing No Interior Surface 6 Cart Garage Zone»great room R-0 Interior Wall 292 0 n/a Existing No Roof R-38 6 Cart Garage Zone R-38 + RI Roof Attic 562 n/a Existing No 80d Wall 6 2 Car Garage -Renovation R-21 Wall (W21.2x6.16) 80 Front 316 160 90 n/a Existing No New 80d Wall 2 Car Garage -Renovation New R-21 Wall 80 Front 160 0 90 n/a Existing No 170d Wall 7 2 Car Garage -Renovation R-21 Wall (W21.2x6.16) 170 Left 70 0 90 n/a Existing No 260d Wall 6 2 Car Garage -Renovation R-21 Wall (W.21.2x6.16) 260 Back 342 63.8 90 n/a Existing No New 260d Wall 2 Car Garage -Renovation New R-21 Wall 260 Back 64 0 90 n/a Existing No 350d Wall 7 2 Car Garage -Renovation R-21 Wall (W.21.2x6.16) 350 Right 255 0 90 n/a Existing No Interior Surface 7 2 Car Garage-Renovation»g uest-4 R-0 Interior Wall 224 0 n/a Existing No Roof R-38 7 2 Car Garage -Renovation I R-38 + R13 Roof Attic 1054 n/a Altered n/a ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Suite 1 Attic RoofSuite 1 Ventilated 3 0.62 0.83 No Yes Existing No Attic great room Attic Roofgreat room Ventilated 3 0.62 0.83 No Yes Existing No Attic 2 Attic Roof2 Ventilated 3 0.62 0.83 No Yes Existing No Attic 3 Attic Roof3 Ventilated 3 0.62 0.83 No Yes Existing No Attic guest-4 Attic Roofgueat-4 Ventilated 3 0.62 0.83 No Yes Existing No Attic Cart Garage Zone Attic RoofCartGarage Zone Ventilated 1 3 1 0.62 1 0.83 1 No Yes Existing No Attic 2 Car Garage -Renovation Attic Roof2 Car Garage -Renovation Ventilated 3 0.62 0.83 No Yes Existing No Registration Number: 218-po11)266171C-000-000-D000000-0000 Registration Dateffime: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI iTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Ratpack Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-18.ribdl6x CF 'RF-01 Page 6 of 13 FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Verified Existing Condition D2 170d Wall (Left-170) 4.1 10.0 1 41.0 0.37 0.26 Insect Screen (default) Existing No 22 170d Wall (Left-170) 5.3 j 10.0 1 53.0 0.46 0.31 Insect Screen (default) Existing No D3 170d Wall (Left-170) 10.6 3.0 1 31.8 0.37 0.26 Insect Screen (default) Existing No 21 260d Wall (Back-260) 13.3 10.0 1 133.0 0.46 0.31 Insect Screen (default) Existing No D1 350d Wall (Right-350) -- - 1 30.2 0.37 0.26 Insect Screen (default) Existing No 20 350d Wall (Right-350) ---- 1 64.0 0.46 0.31 Insect Screen (default) Existing No C2 350d Wall (Right-350) 1 12.0 0.50 0.20 Insect Screen (default) Existing No 01 80d Wall 2 (Front-80) 5.0 11.0 1 55.0 0.94 0.49 Insect Screen (default) Existing No 58 80d Wall 2 (Front-80) 21.5 10.0 2.2 473.0 0.46 0.31 Insect Screen (default) Existing No G4 80d Wall 2 (Front-80) - - 1 47.6 1 0.37 0.26 Insect Screen (default) Existing No 04 170d Wall 2 (Left-170) ---- ---- 1 178.0 0.46 0.31 Insect Screen (default) Existing No A 170d Wall 2 (Left-170) 5.0 11.0 2.335 128.4 0.37 0.26 Insect Screen (default) Existing No 23 170d Wall 2 (Left-170) 7.0 11.0 1 77.0 0.76 0.18 Insect Screen (default) Existing No E2 170d Wall 2 (Left-170) 6.3 15.1 1 95.1 0.37 0.26 Insect Screen (default) Existing No G2 170d Wall 2 (Left-170) - ---- 1 16.1 0.37 0.26 Insect Screen (default) Existing No G3 170d Wall 2 (Left-170) --- ---- 1 16.4 0.37 0.26 Insect Screen (default) Existing No 24 260d Wall 2 (Back-260) 473.0 11.0 0.091 473.5 0.46 0.31 Insect Screen (default) Existing No G1 260d Wall 2 (Back-260) -- - 1 47.6 0.37 0.26 Insect Screen (default) Existing No E1 260d Wall 2 (Back-260) 12.9 15.1 1 194.8 0.37 0.26 Insect Screen (default) Existing No B 350d Wall 2 (Right-350) - - 1 177.0 0.37 0.26 Insect Screen (default) Existing No G5 350d Wall 2 (Right-350) - 1 55.0 0.37 0.26 Insect Screen (default) Existing No G6 350d Wall 2 (Right-350) ---- - 1 23.8 0.37 0.26 Insect Screen (default) Existing No C1 350d Wall 2 (Right-350) ---- 1 16.5 0.50 0.20 Insect Screen (default) Existing No 32 170d Wall 3 (Left-170) - -- 1 78.0 0.46 0.31 Insect Screen (default) Existing No F1 170d Wall 3 (Left-170) - ---- 1 30.2 0.37 0.26 Insect Screen (default) Existing No 28 260d Wall 3 (Back-260) 10.8 10.0 1 108.0 0.46 0.31 Insect Screen (default) Existing No 27 350d Wall 3 (Right-350) 5.3 10.0 1 53.0 0.46 0.31 Insect Screen (default) Existing No 26 350d Wall 3 (Right-350) 3.5 10.0 1 35.0 0.46 1 0.31 Insect Screen (default) Existing No Registration Number: 218-Po10266171C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI iTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Ratpack Calculation Description: Title 24 Analysis •m0 Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-18.ribd16x CF 'RF-01 Page 7 of 13 37 80d Wall 3 (Front-80) -- 1 88.0 0.46 0.31 Insect Screen (default) Existing No F2 170d Wall 4 (Left-170) ---- - 1 30.2 0.37 0.26 Insect Screen (default) Existing No 42 170d Wall 4 (Left-170) 7.9 10.0 0.987 78.0 0.46 0.31 Insect Screen (default) Existing No 35 350d Wall 4 (Right-350) 3.5 10.0 1 35.0 0.46 0.31 Insect Screen (default) Existing No 36 350d Wall 4 (Right-350) 5.3 1 10.0 1 53.0 10.46 0.31 Insect Screen (default) Existing No 50 170d Wall 5 (Left-170) - - 1 80.0 0.46 0.31 Insect Screen (default) Existing No F3 170d Wall 5 (Left-170) - 1 30.2 0.37 0.26 Insect Screen (default) Existing No 45 260d Wall 4 (Back-260) 8.9 1 10.0 0.989 88.0 0.46 0.31 Insect Screen (default) Existing No 44 350d Wall 5 (Right-350) 4.4 10.0 0.977 43.0 0.46 0.31 Insect Screen (default) Existing No 43 350d Wall 5 (Right-350) 3.5 10.0 1 35.0 0.46 0.31 Insect Screen (default) Existing No 55 80d Wall 6 (Front-80) 8.0 10.0 1 80.0 0.46 0.31 Insect Screen (default) New n/a 59 80d Wall 6 (Front-80) 8.0 10.0 1 80.0 0.46 0.31 Insect Screen (default) New n/a New 19.9X2 260d Wall 6 (Back-260) 19.9 2.0 1 39.8 0.37 0.26 Insect Screen (default) New n/a New 12X2 260d Wall 6 (Back-260) 12.0 2.0 1 24.0 0.37 0.26 Insect Screen (default) New n/a OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U-factor Status Verified Existing Condition Door 08 260d Wall 5 110.4 0.08 Existing No Door 09 350d Wall 6 78.4 0.08 Existing No :J Registration Number: 218-Po10266171C-000-000-0000000-0000 Registration DateRme: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI XE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF-01 Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-18.ribd16x Page 8 of 13 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 og 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up D2 4 0.1 4 4 0 0 0 0 0 1 0 0 0 0 22 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D3 4 0.1 4 4 0 0 0 0 0 0 0 0 0 21 4 0.1 4 4 0 0 0 0 0 0 0 0 0 01 4 0.1 4 4 0 0 0 0 0 0 0 0 0 58 12 0.1 12 12 0 0 0 0 0 0 0 0 0 A 4 0.1 4 4 0 0 0 0 0 0 0 0 0 23 8 0.1 8 8 0 0 0 0 0 0 0 0 0 E2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 24 12 0.1 12 12 0 0 0 0 0 0 0 0 0 E1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 28 4 0.1 4 4 0 0 0 0 0 0 0 0 0 27 4 0.1 4 4 0 0 0 0 0 0 0 0 0 26 8 0.1 8 8 0 0 0 0 0 0 0 0 0 42 10 0.1 10 10 0 0 0 0 0 0 0 0 0 35 8 0.1 8 8 0 0 0 0 0 0 0 0 0 36 4 0.1 4 4 0 0 0 0 0 0 0 0 0 45 4 0.1 4 4 0 0 0 0 0 0 0 0 0 44 4 0.1 4 4 0 0 0 0 0 0 0 0 0 43 4 0.1 4 4 0 0 0 0 0 0 0 0 0 55 4 0.1 4 4 0 0 0 0 0 0 0 0 0 59 4 0.1 4 4 0 0 0 0 0 0 0 0 0 New 19.9X2 4 0.1 4 4 0 0 0 0 0 0 0 0 0 New 12X2 4 0.1 4 11 4 0 0 0 1 0 0 0 1 0 0 0 Registration Number: 218-Po10266171C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Ratpack Calculation Description: Title 24 Analysis 'HOD Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-18.ribdl6x CF 'RF-01 Page 9 of 13 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofSuite 1 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 + R13 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall (W21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 • Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 • Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck. Wood Siding/sheathing/decking Attic Roofgreat room Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insuL /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing. Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofguest-4 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing. Light Roof (Asphalt Shingle) Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCart Garage Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd Attic Roof2 Car 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Garage -Renovation Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing., Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 New R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco Registration Number: 218_Po10266171C-000-000-0000000-0000 Registration Date/Time. HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE , HOD Project Name: Ratpack Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Ratpack Remodel-Stein-18.ribdl6x CF . PRF-01 Page 10 of 13 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab Suite 1 862 100 None 0.8 No Existing No Covered Slab 2 great room 3995 88 None 0.8 No Existing No Covered Slab 3 2 662 83 None 0.8 No Existing No Covered Slab 4 3 662 83 None 0.8 No Existing No Covered Slab 5 guest-4 753 121 None 0.8 No Existing No Covered Slab 6 Cart Garage Zone 562 85 None 0 No Existing No Covered Slab 7 2 Car Garage -Renovation 1054 120 None 0 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 2 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 2 50 0.66 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a Registration Number: 218-Po10266171C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ' HOD Project Name: Ratpack Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Ratpack Remodel-Stein-18.ribd16x CF `RF-01 Page 11 of 13 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Distribution Verified Existing SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Name Status Condition HVAC 1 mstrl Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution Existing No System System 1 HVAC 2. 3 & 42 Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution Existing No System System 2 HVAC 5 & 63 Heat Pump Heating and Cooling System Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 Existing No HVAC 64 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 Existing No HVAC 85 Heat Pump Heating and Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution Existing No Cooling System System 5 HVAC 7 & 86 Heat Pump Heating and Cooling System Heat Pump System 6 Heat Pump System 6 HVAC Fan 6 Air Distribution System 6 Altered No HVAC - HEAT PUMPS 01 02 03 04 05 1 06 07 1 08 09 10 11 Name System Type Number of Units Heating HSPF/COP Cap 47 Cap 17 Cooling SEER EER Zonally Controlled Compressor Type HERS Verification Heat Pump System 6 SplitHeatPump 2 10 26000 15600 1 19,7712 Zonally Controlled Single Speed Heat Pump System 6-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 6-hers-cool Required 150 Required Required Required Registration Number: 218-Po10266171C-000-000-0000000-0000 Registration Dateffime: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERT! 1TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Ratpack Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-18.ribd16x CF aRF-01 Page 12 of 13 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located entirely in Existing (not 8'0 Conditioned Conditioned None Existing No n/a System 1 conditioned space specified) Zone Zone Air Distribution Ducts located entirely in Existing (not 8'0 Conditioned Conditioned None Existing No Na System 2 conditioned space specified) Zone Zone Air Distribution Ducts located entirely in Existing (not Conditioned Conditioned System 3 conditioned space specified) 8'0 Zone Zone None Existing No n/a Air Distribution Ducts located entirely in Existing (not 8'0 Conditioned Conditioned None Existing No n/a System 4 conditioned space specified) Zone Zone Air Distribution Ducts located entirely in Existing (not 8'0 Conditioned Conditioned None Existing No Na System 5 conditioned space specified) Zone Zone Air Distribution Ducts located in attic Specified Lower Air Distribution System 6 (Ventilated and Leakage Target 8.0 Attic Attic None New No System Unventilated) 6-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 6-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC - FAN SYSTEMS & HERS VERIFICATION 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required PROJECT NOTES The Madison Club Registration Number: 218-P010266171C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 08:15, Wed, Dec 19, 2018 Input File Name: Ratpack Remodel-Stein-1 8. ribd 1 6x CF IRF-01 Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. Address: CEA/HERS Certification Identification (If applicable). 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of Califomia: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: � Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. Address: License- 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Easy to Verify at CaICERTS.com Registration Number: 218-Po10266171C-000-000-0000000-0000 Registration Dateffime: HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-19 08:17:13 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 8,550 n/a Date 11211912018 # of Units 1 Project Address 53-525 Humbolt Blvd. La Quinta INSULATION Construction Type Cavity Area (ft) Special Features Status Roof Wood Framed Attic R 38 862 Cool Roof Existing Wall Wood Framed R 21 150 Existing Wall Wood Framed R 21 594 Existing Wall Wood Framed R 21 307 Existing Wall Wood Framed R 21 794 Existing Slab Unheated Slab -on -Grade no insulation 862 Perim = 100' Existing Demising Wood Framed - no insulation 424 Existing Roof Wood Framed Attic R 38 3,995 Cool Roof Existing FENESTRATION Orientation Area ff Total Area: 3,528 Glazing Percentage: 41.3 °% U-Fac SHGC Overhang Sidefins NewlAItered Avers a U-Factor. Exterior Shades 0.4$ Status Left (S) 201.2 0.370 0.26 4.0 none Bug Screen Existing Left (S) 53.0 0.460 0.31 4.0 none Bug Screen Existing Rear (W) 329.0 0.460 0.31 4.0 none Bug Screen Existing Right (N) 286.0 0.370 0.26 none none Bug Screen Existing Right (N) 64.0 0.460 0.31 none none Bug Screen Existing Right (N) 28.5 0.500 0.20 none none Bug Screen Existing Front (E) 55.0 0.940 0.49 4.0 none Bug Screen Existing Front (E) 473.0 0.460 0.31 12.0 none Bug Screen Existing Front (E) 47.6 0.370 0.26 none none Bug Screen Existing Left (S) 336.0 0.460 0.31 none none Bug Screen Existing Left (S) 77.0 0.760 0.18 8.0 none Bug Screen Existing Left (S) 95.1 0.370 0.26 10.0 none Bug Screen Existing Left (S) 123.1 0.370 0.26 none none Bug Screen Existing Rear (W) 473.0 0.460 0.31 12.0 none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 3 Central Furnace 80% AFUE 80% AFUE Split Air Conditioner 16.0 SEER Split Air Conditioner 16.0 SEER Setback Setback Existing Existing 2 Split Heat Pump 10.00 HSPF HVAC DISTRIBUTION Location Heating Split Heat Pump 17.7 SEER Cooling Duct Location Setback Duct R-Value Existing Status HVAC 1 mstr Ducted Ducted Conditioned 8.0 Existing HVAC 2, 3 & 4 Ducted Ducted Conditioned 8.0 Existing HVAC 5 & 6 Ducted Ducted Conditioned 8.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Emerc • Pro 7.2 by EneCqySoft User Number: 6712 ID: Page 16 of 53 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence TBuilding Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211912018 Project Address 53-525 Humbolt Blvd. La Quinta f California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,550 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ft) Special Features Status Wall Wood Framed R 21 480 Existing Wall Wood Framed R 21 64 Existing Wall Wood Framed R 21 237 Existing Wall Wood Framed R 21 160 Existing Slab Unheated Slab -on -Grade no insulation 3,995 Perim = 88' Existing Demising Wood Framed no insulation 424 Existing Roof Wood Framed Attic R 38 662 Cool Roof Existing Wall Wood Framed R 21 122 Existing FENESTRATION Orientation Area(ft2) Total Area: 3.528 Glazing Percentage: 41.3 % U-Fac SHGC Overhang Sidefins NewlAltered Average U-Factor: 0.43 Exterior Shades Status Rear (W) 47.6 0.370 0.26 none none Bug Screen Existing Rear (W) 194.8 0.370 0.26 10.0 none Bug Screen Existing Right (N) 184.0 0.460 0.31 4.0 none Bug Screen Existing Right (N) 70.0 0.460 0.31 8.0 none Bug Screen Existing Front (E) 88.0 0.460 0.31 none none Bug Screen Existing Left (S) 78.0 0.460 0.31 10.0 none Bug Screen Existing Front (E) 160.0 0.460 0.31 4.0 none Bug Screen New Rear (W) 63.8 0.370 0.26 4.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.7 SEER Setback Existing 1 Split Heat Pump 11.30 HSPF Split Heat Pump 18.0 SEER Setback Existing 2 Split Heat Pump 10.00 HSPF HVAC DISTRIBUTION Location Heating Split Heat Pump 19.7 SEER Cooling Duct Location Setback Altered Duct R-Value Status HVAC 6 Ducted Ducted Conditioned 8.0 Existing HVAC 8 Ducted Ducted Conditioned 8.0 Existing HVAC 7 & 8 Ducted WATER HEATING Qty. Type Ducted Attic 8.0 New Gallons Min. Eff Distribution Status Enero Pro 7.2 by EnerqySoft User Number: 6712 ID: Pace 17 of 53 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 8,550 n/a Date 1211912018 # of Units 1 Project Address 53-525 Humbolt Blvd. La Quinta INSULATION Construction Type Cavity Area (ft) Special Features Status Wall Wood Framed R 21 Wall Wood Framed R 21 212 142 Existing Existing Slab Unheated Slab -on -Grade no insulation 662 Perim = 83' Existing Demising Wood Framed no insulation 230 Existing Roof Wood Framed Attic R 38 662 Cool Roof Existing Wall Wood Framed R 21 232 Existing Wall Wood Framed R 21 122 Existing Wall Wood Framed R 21 142 Existing FENESTRATION Total Area: 3.528 GlazinR Percentage: 41.3 %J NewlAltered Average U-Factor: Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades 0.113 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnarqyPfo 7.2 by EneraySaft User Number., 6712 ID: Pape 18 of 53 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11211912018 Project Address 53-525 Humbolt Blvd. La Quinta California Energy Climate Zone I Total Cond. Floor Area CA Climate Zone 15 8,550 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area ftz S ecial Features Status Slab Unheated Slab -on -Grade no insulation 662 Perim = 83' Existing Demising Wood Framed no insulation 230 Existing Roof Wood Framed Attic R 38 753 Cool Roof Existing Wall Wood Framed R 21 200 Existing Wall Wood Framed R 21 220 Existing Wall Wood Framed R 21 112 Existing Wall Wood Framed R 21 252 Existing Slab Unheated Slab -on -Grade - no insulation 753 Perim = 121' Existing FENESTRATION Total Area: 3,528 Glazing Percentage: 4T•3 % New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades 0.43 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 7.2 by EnerqySoft User Number: 6712 ID: Page 19 of 53 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211912018 Project Address 53-525 Humbolt Blvd. La Quinta California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 8,550 n/a Of of Units 1 INSULATION Construction Type Cavity Area ft Special Features Status Demising Wood Framed - no insulation 124 Existing Roof Wood Framed Attic R 38 562 Cool Roof Existing Wall Wood Framed R 21 190 Existing Wall Wood Framed R 21 35 Existing Wall Wood Framed R 21 Door Opaque Door - no insulation 240 110 Add=R-12.0 Existing Existing Wall Wood Framed R 21 200 Existing Door Opaque Door - no insulation 78 Add=R-12.0 Existing FENESTRATION I Totat Area: 3.528 Glazing Percentage: 41.3 % New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades 0.43 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnenqyPro 7.2 by Enerp Soft User Number: 6712 ID: Page 20 of 53 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Project Address 53-525 Humbolt Blvd. La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211912018 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,550 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area ft Special Features Status Slab Unheated Slab -on -Grade no insulation 562 Perim = 85' Existing Demising Wood Framed no insulation 292 Existing Roof Wood Framed Attic R 38 1,054 Cool Roof Altered Wall Wood Framed R 21 156 Existing Wall Wood Framed R 21 160 Existing Wall Wood Framed R 21 70 Existing Wall Wood Framed R 21 278 Existing Wall Wood Framed R 21 64 Existing FENESTRATION I Total Area: 3,528 Glazing Percentage: 41.3 VolNew/Altered Average U-Factor. 0.43 Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ewer Pro 7.2 by EnetlqySoft User Number.- 6712 ID: Pape 21 of 53 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Project Address 53-525 Humbolt Blvd. La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 8,550 n/a Date 11211912018 # of Units 1 INSULATION Construction Type Area Cavity ft Special Features Status Wall Wood Framed R 21 255 Existing Slab Unheated Slab -on -Grade - no insulation 1, 054 Perim = 120' Existing Demising Wood Framed - no insulation 224 Existing FENESTRATION I Total Area: 3,528 t3lazin Percentage: 41.3 % New/Altered Average U-Factor. Orientation Area U-Fac SHGC Overhang Sidefins Exterior Shades 0.43 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 7.2 by EnerqvSoft User Number: 6712 ID: Page 22 of 53 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Revised 04/20171 Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 10l/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, aasketed. or weather striooed. _ § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material, § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of ,110.8 when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: requirement also applies to controlled ventilation crawls ace for buildings oomplyIng with the exception to § 150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls vented attics and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting dam er or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified b.y the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating, is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage conneclian w€th p1lot tights that consume less than 150 Btu/hr are exempt): and pool and sa heaters' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using desi n conditions specified in § 150.0 h 2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.06)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC) or by a listing a enc that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing,that the insulation meets this requirement, CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems, Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct.00nstruction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic. dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m l land Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet In length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, ressure drop, and labe Ing requirements of§ 150.0(m)12. e2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <- 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o) continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods, § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9.. Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Ener y Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JAB.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E.' § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 f • and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(K)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9 and complies with all other applicable requirements in § 150.0.Ck). __ _. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be con trolled_by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0,130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9 130.0. 130.2,130.4 140.7 and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined accordin to 5 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9.130.0. 130.1, 130.4 140.E and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the raq uirements of 5 110.10 b th ro49 h § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1; greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 oeitem of the total roof area of the building excluding any skylight area! § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10ld): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §110.10(c) must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 12/19/2018 System Name HVAC 1 mstr Floor Area 862 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 853 Return Vented Lighting Return Air Ducts Return Fan Ventilation 147 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 17,822 1,031 459 19,363 Total Output Btuh 89,000 0 Output Btuh/s ft 103.2 258 230 Cooling System 0 0 Output perSystem 59,000 5,595 3,071 147 7,157 Total Output Btuh 59,000 2,943 4,102 -2,943 Total Output Tons 4.9 258 230 Total Output Btuh/s ft 68.4 Total Output s ft/Ton 175.3 1 26,877 24,037 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2.000 Day and Night 5 Ton 50,860 0 89,000 Airflow cfm/s ft 2.32 Airflow cfmJTon 406.8 Outside Air % 7.3 °/a Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 50,860 0 Aug 3 PM 89,000 Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 147 cfm AL 72 OF 69 IF 110 IF 112 IF Heating Coil Supply Fan 2,000 cfm 112 IF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Cooling Peak 112 / 78 IF Outside Air 147 cfm 76 / 62 OF 79163 OF 55 / 54 OF 56 / 54 OF �III� Cooling Coil Supply Fan 2,000 cfm 56 / 54 OF — 44.4 % ROOM _ r 76 / 62 IF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 12/19/2018 System Name HVAC 2, 3 & 4 Floor Area 3,995 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 3.890 Return Vented Lighting Return Air Ducts Return Fan Ventilation 806 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 72,113 4.777 1,581 61,936 Total Output Btuh 267,000 0 Output Btuh/s ft) 66.8 1.044 737 Cooling System 0 0 Out ut erS stem 59,000 30,726 13,817 806 39,341 Total Output Btuh 177,000 8.830 18,594 -8,830 Total Output Tons 14.8 1.044 737 Total Output Btuh/s ft 44.3 Total Output s ft/Ton 270.8 113,757 93,921 Air System CFM perS stem 2,000 HVAC EQUIPMENT SELECTION Airflow f cfm 6.000 Day and Night 5 Ton 152.880 5,009 267,000 Airflow cfm/s ft 1.50 Airflow cfmfTon 406.8 Outside Air % 13.4 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 152,8801 5,0091 267,000 Outside Air cfm/s ft 0.20 Note: values above givan at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF vp Outside Air Ar 806 cfm 72 OF If 66 OF 108 IF 109 IF O Heating Coil Supply Fan 6,000 cfm 109 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 806 cfm 76 / 63 IF 81 /65OF 57/56OF 58/56IF a Cooling Coil Supply Fan 6,000 cfm 59 / 56 OF 48.5 % ROOM 76 / 63 IF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Ratpack Residence 12/19/2018 System Name Floor Area HVAC 5 & 6 1,324 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 452 Return Vented Lighting Return Air Ducts Return Fan Ventilation 221 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 50,000 25,529 11583 542 25,205 Total Output Btuh 100,000 0 Output Btuh/s ft 75.5 369 286 Cooling System 0 0 Output per System 45,000 8,380 11,204 221 10,745 Total Output Btuh 90,000 0 12,787 0 Total Output Tons 7.5 369 286 Total Output Btuh/s ft 68.0 Total Output s ft/Ton 176.5 I 34,648L 1 36,523 Air System CFM per System 550 HVAC EQUIPMENT SELECTION Airflow cfm 1,100 Fujitsu FAOU45 71,313 0 62,457. Airflow cfm/s ft 0.83 Airflow cfm/Ton 146.7 Outside Air % 20.1 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 71,313 0 62,457 Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCH ROM ETRICS Airstream Temperatures at Time of Heating Peak 26 OF 63 OF 116 OF 116 OF Outside Air U 1 I [l I 221 cfm Heating Coil Supply Fan 116 OF 1,100 cfm ROOM 72 OF 72 IF f COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 83/58°F 23/21 OF 23/21 OF Outside Air 221 cfm Cooling Coil Supply Fan 23 / 22 OF 1,100 cfm 12.3 % ROOM rl 76 / 51 OF _ , 76.151 °F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 12/19/2018 System Name HVAC 6 Floor Area 753 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 670 Return Vented Lighting Return Air Ducts Return Fan Ventilation 126 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 26,000 13,090 900 1,119 14,742 Total Output Btuh 26,000 0 Output Btuh/s ft 34.5 189 167 Cooling System 0 0 Output jeerSystem 24,000 4,776 2,035 126 6,115 Total Output Btuh 24,000 0 189 1 18,245 2,935 0 Total Output Tons 2.0 167 Total Output Btuh/s ft 31.9 Total Output s ft/Ton 376.5 21,193 Air System CFM perSystem 743 HVAC EQUIPMENT SELECTION Airflow cfm 743 Fujitsu 24RLFCD 19,676 2,019 16,239 Airflow cfm1s ft 0.99 Airflow cfm/Ton 371.5 Outside Air % 16•9 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 19,676 2,019 16,239 Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peaks 26 OF ok Outside Air��u- 126 cfm 72 OF 64 OF 85 OF 85 OF Heating Coil Supply Fan 743 cfm I I I 84 OF ROOM N 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 126 cfm 76 / 63 OF 82/66OF 57/56OF 57/56OF I Cooling Coil Supply Fan 743 cfm l I 58 / 56 OF 49.5 % ROOM 9 ._. T 76 / 63 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 12/19/2018 System Name HVAC 8 Floor Area 562 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 197 Return Vented Lighting Return Air Ducts Return Fan Ventilation 94 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 21,600 4,550 585 471 7,492 Total Output Btuh 21.600 0 Output Btuhls ft 38.4 66 85 Cooling System 0 0 Output erSystem 18,000 3,378 1,768 94 4,571 Total Output Btuh 18,000 0 2,352 0 Total Output Tons 1.5 66 85 Total Output Btuh/s ft 32.0 Total Output s ft/Ton 374.7 1 8,060 12,233 Air System CFM perSystem 550 HVAC EQUIPMENT SELECTION Airflow cfm 550 Fujitsu FAOU18 16,234 0 13,491 Airflow cfm/s ft 0.98 Airflow cfmfTon 366.7 Outside Air % 17.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 16,234 0 13,491 Jan 1 AM Outside Air cfm/s ft 0,17 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heating Peak 26 OF Air 94 cfm 72 OF 64 OF 87 OF 87 OF U I Heating Coil Supply Fan 550 cfm I IOutside I�] FtT "I ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air r 94 cfm 78 / 63 OF 84/66OF 56/55OF 56/55OF O Cooling Coil Supply Fan 550 cfm I 56 / 55 OF 43.7 % ROOM n 78 / 63 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 12/19/2018 System Name HVAC 7 & 8 Floor Area 1,054 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 621 Return Vented Lighting Return Air Ducts Return Fan Ventilation 176 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 26,000 13,749 1.096 983 15,082 Total Output Btuh 52,000 0 Output Btuh/s ft 49•3 794 577 0 Cooling System 0 Output per System 24,000 6,262 3,186 176 8,531 Total Output Btuh 48,000 0 794 1 21,599 4,282 0 Total Output Tons 4.0 577 Total Output Btuh/s ft 45.5 Total Output s ft/Ton 263.5 24,767 Air System CFM per System 743 HVAC EQUIPMENT SELECTION Airflow cfm 1,486 Fujitsu 24RLFCD 40,733 2,175 32,478 Airflow cfmis ft 1.41 Airflow cfm/Ton 371.5 Outside Air % 11.8 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 40,733 2,175 Aug 3 PM 32,478 Outside Air cfmis ft 0.17 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Out Air -41- 176 cfm 72 OF ■ 66 OF 87 IF 87 OF M •l:� i Heating Coil Supply Fan 1,486 cfm j I[� I U 1 86 IF ROOM 72 IF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 176 cfm • 82/65°F 57/55°F 57/55°F 8 1 Cooling Coil Supply Fan 1,486 cfm T-1 I U - i 1 57 / 56 IF -- 44.4 % ROOM 78/63° - _-- ROOM LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 System Name Floor Area HVAC 1 mstr 862 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Suite 1 Ste 1 1 853 17,822 1,031 653 17,822 1,031 4591 19,363 PAGE TOTAL TOTAL* * Total includes ventilation load 853 1 17,822 1,031 459 19,363 853 17.822 1,031 459 19,363 ROOM LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 System Name Floor Area HVAC 2, 3 & 4 3,995 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult.H,8901 FM Sensible Latent CFM Sensible Latent CFM Sensible great room Great Dining Kitchen 172,113 4,777 3,8901 72,1131 4,777 1,5811 61,936 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal 3,894 72,113 4,777 1,581 61,936 3,890 1 72,113 4,777 1,581 61,936 ROOM LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 System Name Floor Area HVAC 5 & 6 1,324 ROOM LOAD SUMMARY ROOM COOLING PEAK I COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 2 Suite 2 1 228 12,889 792 228 12,889 792 275 12,782 3 Suite 3 1 224 12,640 792 224 12, 640 792 2671 I Z 423 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal 452 25,529 1,583 542 25,205 452 25,529 1,583 542 25,205 1 ROOM LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 System Name Floor Area HVAC 6 753 ROOM LOAD SUMMARY ROOM COOLING PEAK Zone Name Room Name Mult. CFM Sensible I Latent guest-4 Suite 4 1 1 1 6701 13,0901 900 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 670 13,0901 900 1,1191 14,742 870 13,090 900 1.119 14.742 670 13,090 900 1,119 14,742 ROOM LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 System Name Floor Area HVAC 8 562 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent I CFM I Sensible Cart Garage Zone Cart Garage 1 1 1971 4,5501 585 197 4,5501 5851 471 7,492 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal systems. 197 4,550 585 471 7,492 197 4,550 585 471 7,492 ROOM LOAD SUMMARY Project Name Date Rafpack Residence 1211912018 System Name Floor Area HVAC 7 & 8 1,054 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 2CarGarage-Renovation Main Garage 1 621 13,749 1,096 621 13,7491 1,096 9831 15,082 PAGE TOTAL TOTAL* 621 13,7491 1,096 983 15,082� 621 13.749 1,096 983 15,a82 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Ste 1 Floor Area 862.00 ftz Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value x x x x x x x X X X X X X X X X X X X X x x x x x x x x x x x AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr _ 771 R-38 + R13 Roof Attic 862.0 x x x 0.0194 46 R-21 Wall (W.21.2x6.16) 1,845.0 0.0690 46 5,856 Monumental.371.26 103.0 0.3700 46 1,753 Monumental.461..31 250.0 x x 0.4600 46 5,290 Monumenlal.50/.20 12.0 0.5000 46 276 Slab -On -Grade perim = 100.0 x 0.7300 46 3,358 'R-0 Interior Wall 424.0 x 0.3560 0 0 X X X X X X X X X X X X X x x x x x x x x x x x Items shown with an asterisk (°) denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interior surface to x 862 x Area Ceiling another room 10.20 x 0.287 Height ITCH Page Total / 60 J X AT 17,304 = 2,059 TOTAL HOURLY HEAT LOSS FOR ROOM 19,363 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Floor Area 3,995.00 ft2 Indoor Dry Bulb Tem erature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 3,995.0 U-Value X 0.0194 X 0.0690 X 0.9400 X 0.4600 X 0.3700 X 0.7600 X 0.5000 X 0.7300 X 0.3560 X X X X X X X X X X X X X X x x x x x x x x to another room 12.10 X 0.242 Ceiling Height ACI AT OF Btu/hr R-38+P13RoofAf[ic X 46 = 3,571 R-21 Wall (W.21.24.16) 940.7 X 46 = 2,986 Custom Entry Door 55.0 X X 46 = = 2,378 Monumental.461.31 1,124.0 46 23,784 Monumenlal.371.26 801.8 X 46 = 13,647 Monumental. 761. 18 7T0 X 46 = 2,692 Monumenfal.501.20 16.5 X 46 = 360 Slab -On -Grade perim = 88.0 X 46 = 2,955 'R-0 Interior Wall 424.0 X 0 = 0 X = X = X = X X = = X X X = = = X = X = X = X X = = X = x = x = x x = = x x = = x = x = Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 3,995 X Area Page Total / 60 ] X 46 I AT 52,392 = 9,544 TOTAL HOURLY HEAT LOSS FOR ROOM 61,936 ROOM HEATING PEAK LOADS Project Name Ratpack Residence bate 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 2 Floor Area 662.00 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 662.0 X 475.8 X U-Value X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x AT OF = = _ = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 + R13 Roof Attic 0.0194 46 592 R-21 Wall (W.21.2x6.16) 0.0690 46 1,510 Monumental .46/.31 274.0 x X 0.4600 46 5,798 Monumental.371.26 30.2 0.3700 46 514 Slab -On -Grade perim = 83.0 x X x x x 0.7300 46 2,787 'R-0 Interior Wall 230.0 0.3560 0 0 x x x x x x x x x x x x x x x x x x x x x x Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 662 X Area Ceiling another room 10.00 x 0.293 Height ACrI Page Total / 60 ] X AT 11,201 1,582 12,782 TOTAL HOURLY HEAT LOSS FOR ROOM ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 3 Floor Area 662.00 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = a = = = = = = = = = = = = = = = 46 Btu/hr R-38 + R13 Roof Adic 662.0 0.0194 46 592 R-21 Wall (W.21.2x6.16) 495.8 0.0690 46 1,574 Monumenfal.461.31 254.0 0.4600 46 5,375 Monumental.371.26 30.2 0.3700 46 514 Slab -Orr -Grade perim = 83.0 0.7300 46 2,787 'R-0 Interior Wall 230.0 0.3560 0 0 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X G62 X Area another room 10.00 X 0.293 Height ACH Page Total / 60 ] X AT 10,841 _ 1,582 TOTAL HOURLY HEAT LOSS FOR ROOM IZ423 ROOM HEATING PEAK LOADS Project Name Date Ratpack Residence 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 4 Floor Area 753.00 ftZ Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area x x X X X X X X X X X X X X X X X X X X X X X X x x x x x x X to Ceiling U-Value x X X X X X X X X X X X X X X X X X X X X X X X x x x x x x x AT OF = = = _ = = = = = = = = = = = = = = = = = = = = = _ 46 Btu/hr R-38 + R13 Roof Attic 753.0 0.0194 46 673 R-21 Wall (W.21,2x6.16) 783.8 0.0690 46 2,488 Monumenla1.46/.31 246.0 0.4600 46 5,205 Monumental.37/.26 30.2 0.3700 46 574 Slab•On-Grade perim = 121.0 0.7300 46 4,063 `R-0 Interior Wall 124.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x 1.064 5chodule Air Sensible Fraction through an interior surface x 753 x Area another room 10.00 x 0.293 Height ACH Page Total / 60 ] X ❑T 12,943 1,799 TOTAL HOURLY HEAT LOSS FOR ROOM 14,742 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Cart Garage Floor Area 562.00 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value X X X X X X X X X X X 1X x X X X X X x x x x x x x x x x x x x AT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R 38 + R13 Root Attic 562.0 X X X 0.0194 46 502 R-21 Wall (W.21.2x6.16) 664.2 0.0690 46 2,108 Insulated Garage Door 188.8 0.0788 46 684 Slab -On -Grade perim = 85.0 X 0.7300 46 2,854 'R-0 IrrferlorWall 292.0 X 0.3560 0 0 X X X X X X X x X X X X X x x x x x x x x x x x x x Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 Schedukc Air Sensible Fraction through an interior surface to X 562 X Area Cciling another room 10.00 X 0.293 Height ACH Page Total / 60 ] X AT 6,149 = 1,343 TOTAL HOURLY HEAT LOSS FOR ROOM 7,492 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Main Garage Floor Area 1,054.00 ft2 Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area _ X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x to Ceiling U-Value 0.0194 X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x AT OF = = = = c = = = 46 Btu/hr R•38 + R13 Roof AHic 1,054.0 46 942 R-21 Wall (W,21.2x6.16) 759.2 0.0690 46 2,410 New Monumental .481..31 160.0 0.4600 46 3,386 Now R-21 Walt 224.0 0.0690 46 711 New Monumental .371.26. 63.8 0.3700 46 1,066 Slab -On -Grade perim = 120.0 0.7300 46 4,030 'R-0 Interior Wall 224.0 0.3560 0 0 _ Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 5chadule Air Sensible Fraction through an interior surface X 1,054 X Area another room 10.00 X 0.293 Height ACH Page Total / 60 ] X AT 12,584 2,518 TOTAL HOURLY HEAT LOSS FOR ROOM 15,082 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Ste 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 862.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U_-Factor CLTD' Btu/hr R-38 + R13 Rcof Alfic (W) 862,0 X 0.0194 X 56.0 = 938 R-21 Wall (W.21.2x6.16) (E) 150.0 X 0.0690 X 32.1 = 332 R-21 Wafl (W.21.24.16) (S) 594.2 X 0.0690 x 27.1 = 1.112 R-21 Wall (W.21.2x6.16) (W) 307.0 X 0.0690 X 32.6 = 690 R-21 Wall (W21.2x6.16) (N) 793.8 X 0.06901 X 29.0 = 1,588 'R•0 tnteriar Wall 424.0 X 0.3560 X 0.0 = 0 x x = x x = x x = Page Total 4,660 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr D2 (S) 41.0 X 17.0 + 0.0 X 18.4 = 699 22 (S) 53.0 X 20.7 + 0.0 X 22.3 = 1;097 03 (S) 31.8 X 17.0 + 0.0 X 18.4 = 642 21 (W) 49.6 X 20.7 + 83.4 X 38.4 = 4,231 01 (N) 0.0 X 17.0 + 30.2 X 25.4 = 767 20 (N) 0.0 X 20.7 + 64.0 X 30.7 = 1,963 C2 (N) 0.0 X 17.4 + 12.0 X 23.9 = 286 X + X = X 1 +1 X = Page Total 9.58G Internal Gain Btu/hr Occupants 2.6 Occupants x 245 Btuh/occ. = 634 E ui ment 862 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.88 X 43.46 X 36 - 1,471 Air Sensible CFM Elk AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,822 Latent Gain Btu/hr Occupants 2 6 Occupants X 155 Btuh/occ. 401 Infiltration: 4,771 X 0.88 X 1 43.46 X 0.00344 = 630 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 401 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 3,995.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 °F Outdoor Daily Range: 34 OF Ouaaue Surfaces R-38 + R13 RoorAf6c R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W-21.2x6.15) R-21 Wall (W.21.2x6.16) Interior Wall Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = c = = = 3,995.0 0.0194 56.0 480.4 00690 32.1 64.0 0.0690 27.1 236.6 0.0690 0.0690 32.6 159.7 29.0 424.0 0.3560 0.0 Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration 01 58 G4 04 A 23 E2 G2 G3 Orientation (E) (E) (E) (S) (S) (S) (S) (S) (S) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 11.9 37.0 43.1 63.1 348.4 20.7 124.6 37.2 0.0 17.0 47.6 30.9 0.0 20.7 178.0 22.3 128.4 17.0 0.0 18.4 77.0 21.9 0.0 22.8 95.1 17.0 17.0 0.0 18.4 0.0 16.1 18.4 0.0 17.0 16.4 18.4 Page Total Btu/hr 1 5311 Btu/hr 3.159 11,852 1,471 2. 1 1,6211 Internal Gain Btu/hr Occupants 12.0 Occupants X 2451 Btuh/occ. E ui menE 3,995 Floor Area X 0.50 w/sgft 6,1 Infiltration: 1.064 X 0.88 X 201.42 X 36 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,113 Latent Gain Btu/hr Occupants 12.0 Occupants X 155' Btuh/occ. _ 1,858 Infiltration: 4.771 X 0.88 X 201.42 X 0.003441 = Z919 Air Latent CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,8581 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 3,995.00 ft' Outdoor Wet Bulb Temperature 78 OF Indoor My Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' X X Btu/hr = X X - X X = X X = X X - X X = X X = X X = X X - Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 24 (W) 473.0 X 20.7 + 0.0 X 38.4 = 9.701:i G1 (W) 0.0 X 17.0 + 47.6 X 31.9 = 1.519 El (W) 122.3 X 17.0 + 72.5 X 31.9 = 4,399 B (N) 0.0 X 17.0 + 177.0 X 25.4 = 4,497 G5 (N) a 0 X 17.0 + 55.0 X 25.4 = 1.396 G6 (N) 0.0 X 17.0 + 23.8 X 25.4 = 605 C1 (N) 0.0 X 17.4 + 16.5 X 23.9 = 394 X + X = X +1 X Page Total 22,604 Internal Gain Btu/hr Occupants 12.0 Occupants X 2451 Btuh/occ. = 2,936 Equipment 3,995 1 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.88 X 201.42 X 36 = 6,619 Air Sensible CFNI ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,113 Latent Gain Btuihr Occupants 12.0 _ Occupants X 1551 Btuh/occ. = 1.858 Infiltration: 4,771 X 0.88 X 201.42 X 0.00344 = 2,919 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,858 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 662.00 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr R-38+R13Root Aftic (W) 662.0 X 0.0194 X 56.0 = 720 R-21 Wall (W.21.2x8.16) (S) 121.8 X 0.0690 X 27.1 = 228 R-21 Walt (W21.2x6.16) (W) 212.0 X 0.0690 X 32.6 = 476. R-21 Wall (W.21.2x6.16) (N) 142.0 x 0.0690 X 29.0 = 284 'R-0 Interior Wall 230.0 x 0.3560 X 0.0 = 0 x x = x x = - x x = � x x = Page Total 1,709 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 32 (S) 0.0 X 20.7 + 78.0 X 22.3 = 1,743 F1 (S) 0.0 X 17.0 + 30.2 X 18.4 = 556 28 (W) 40.3 X 20.7 + 67.7 X 38.4 = 3,436 27 (N) 0.0 X 20.7 + 53.0 X 30.7 = 1,626 26 (N) 0.0 X 20.7 + 35.0 X 30.7 = 1,074 X + X - X + X = X + X = X + X = Page Total 8,435 Internal Gain Btu/hr Occupants 2 0 Occupants X 245 Btuh/occ. = d130 Equipment 662 Floor Area X 0.50 w/sgft _ 1, Infiltration: 1.064 X 0.88 X 33.38 X 36 = 1,130 Air Sensible CFM E1.A AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,889 Latent Gain Btu/hr Occupants 2 0 Occupants X 155 Btuh/occ. = 308 Infiltration: 4,771 X 0.88� X 33.38 X 0.00344 = 484 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 308 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 662.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 °F Outdoor Daily Ran e: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 + R13 Roof Attic (W) 662.0 X 0.0194 X 56.0 = 720 R-21 Wall (W.21.2x6,16) (E) 232.0 X 0.0690 X 32.1 = 514 R-21 Wall (W.21.2x6.16) (S) 121.8 X 0.0690 X 27.1 = 228 R-21 Wall (W.21.2x6.16) (N) 142.0 X 0.0690 X 29.0 = 284 'R-0 Interior Wall 230.0 X 0.3560 X 0.0 = 0 X X = X X = X X = _ X X Page Total 1,746 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 37 (E) 0.0 X 20.7 + 88.0 X 37.2 = 3,277 F2 (S) 0.0 X 17.0 + 30.2 X 18.4 = 555 42 (S) 78.0 X 20.7 + 0.0 X 22.3 = 1.615 35 (N) 0.0 X 20.7 + 35.0 X 30.7 = 1,074 36 (N) 0.0 X 20.7 + 53.0 X 30.7 = 1.626 X + X = X + X = X + X = X + I X = Page Total 8,14 Internal Gain Btu/hr Occupants 2.0 Occupants X 245 Btuh/occ. = �-A Equipment 662 Floor Area X 0.50 wlsgft _ Infiltration: 1.064 X 0.88 X 33.38 X 36 m 1,130 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM _ 12,640 Latent Gain Occupants 2 0 Occupants X 155 gtuh/ocC. = _B_tulhr Infiltration: 4,771 X 0.88 X 33.38 X I 0.00344 Air Latent CFM ELA ❑W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 308 05� WOO2! NOj NIVO 1V3H 1N31V1 AjynOH 1V1O1 MV V19 Wjo lUa1e1 xv 055 ti6E00'0 1 X 9fi X 88'0 X LLL`b :uol;ea;I!;ul 09£ = 000/4nII3 99L X sluednoop £•Z slue naap a4/n�8 _ uleJ ;u83e"1 060'£L WOO2! HO=l NIVO 1V3H 3181SN3S AjzJnOH IV1O,l 98Z'L 10 V13 Wjo alq!suasa!y = 9E X 96'1E X 88'0 X b90'L :uol;ea;ll;ul 8Z'L )4bs/m 09'0 X eaay cool j £9L luaw !n 3 £95 = 000/4n;8 9bZ X sluednoop £•Z slue noop a4/n;8 uleJ IeUaa;ul 9E9'L le;ol a6ed X.. + X = X + X = X + X = X + X tiL0'L = L'0£ X 0'9£ + L'OZ X 0'0 (N) £b 6L£`L = L-0£ X 0'£ti + L'OZ X 0-0 (N) y� 008`Z = b'B£ X Z'99 + L'OZ X .8'Z£ (M) 96 99.9 = V8L X Z"OE + 0'LL X 0'0 (S) £=l 88L `L = £'ZZ X 0'09 + L'00 X 0'0 (S) 09 a4/n;8 dl� easy AID easy uol;epolio uol;ea;sauaj Pope4sun POPe4S ((il-lo) aouejelL!Q aan;eaadwa_Lpeol 6u!l000 • l •wooa aayloue o; eoe}jns joualui ue y6noayl uoi;onpuoo alouep (,) Nsualse ue y;!m umoys swa;l oEti'Z le;o1 a6ed _ X X = X X = X X 0 = O'0 X 099£'0 X O'6ZL Hem aouelu/ 0-L4 b09 = O'6Z X 0690'0 X 19 (N) (9L'9XZ'L3'M) IIeM LZ-8 Z9Z = 9'Z£ X .0690.0 X O'ZLL (M) (9L'9XZ'LZ'M) IIeM LZ-& LLti = L'LZ X •0690-0 X i9'6LZ (S) (9L'9XZ'LZ'M) IIeM LZ 21 L'Z£ X •0690'0 X 19*OOZ (3) (94'9XZ'LZ'M) IIeM LZ-LI 6W = 0'99 X 66L0'0 X O'E9L (M) 017IVJOO& £L2/ + 8E-2i a4/n38 ,aria ao;oed-n eaay uol;e;ualap sooe}ans an e p =10 /,£ :a uetl Aliea aoop;np _q0 9L aan;eaadwal gln8 a aoopul =10 82 empuedwal gln8 ;eM aoop;np z 00'i9L easy aoold Jo Zd d aan;eaadwal gln8 Aia coop;np p, alms aweN wooa SNOI11aNOO NOIS3a NOI1VWUOdNl WOON 860E16l/Zd eouepsaLj )joedle& 9;e4 aweN ;oaload Auvwwns avo-i ON11003 WOOH IVI1N341S3y 69Z WO02! 2103 NIVJ 1V3H 1N31V"1 AjynOH lV1Ol MV V+ 3 W30 Suawl i!v $ES = 9LZ0 X EE'9Z 00'X L9.0 X LLL'ti :uol3eJ3113ul - - - 1 3g� _ •000/yn;8 99k 1 X s;uednoop L•1 slue noop ay/n;8 ule0;ua;e-I 055'ti WOON HO=I NIVO 1V3H 3181SN3S AjunOH IV1Ol 1V V13 W30 a€C{lsuas ny $8$ = h£ X EE'9Z X ze-0 X yg0•y :uol;ea;ll3ul 696 = 4bs/M 09.0 X eaay .€oold 79S 3uaw In 3 El.b - 000/4n3s 9tiZ X s;uednoop L•1 slue noap a4/n3s uleE) leuaa;ul 0 le;ol aBed - X + X - — = X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X j4/n3s dip eaiv AID eeiv uol;e;uauo uol;ea;seu9=1 �! papeysufl papeyg (alto) aouala}114 oIn}ejadwal peon 6uil000 •f -woe iauloue of aoe}ans joua3ui ue y6nay} uoilonpuoo ajouap ,() �siaa;se ue q)!m umoys swell 060'Z le;ol aBed - X X X .099E'0 X TWE OM -10MOM 0-8. 6L L = 0"6Z X .9BL0.0 X vq/ (N) looQ often pole/nsu/ 66S = O'6Z X �0690'0 X 9'66d (N) (9!'9xZ'lZiVl) I/eM Le -a £8Z = f9'ZE X 'B8L0-0 X b'Ol L (M) looQ BGeieo polelnsu/ 9E9 a 9"ZE X 0690'0 X 9'6EZ (M) (9v9XZ'6Z'm) item !Z-H 59 = l'LZ X 0690.0 X •0-9E (S) (96'9xZ'izM) Item ZZ-a iZh d'ZE X 0690.0 X 0.06l (3) (9v9xz,tz I) om te-a ZO = 0'9S X 66d0'0 X O'Z99 (M) 0111VIo08 eta + GE -a j4/n3s �al�a ao;aed-� ea.1br uol;e;ualap se3epng en e p -4o bE :a ueM Alleaioopino jo 8L ain;eaadwal gln8 tua joopul J0 8L ain;eiadwal glnB;aMjoop;no z#! 00•Z99 BeivJool=1 =10 Z6l ain;ejedwal glns A -,a joop;no a8ete0 peo aweN wood SNOI11aN00 NOIS3a NOI1VWNO=IN1 WOON 8kOZ/6l/,k eouepise& )/oedjeV eje4 aweN loafed ,kmvWWf1S avo-i JNI'1000 WOOD '1VIIN3aIS9H RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1211912018 ROOM INFORMATION DESIGN CONDITIONS Room Name Main Garage Outdoor Dry Bulb Temperature 112 OF Floor Area 1,054.00 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Drx Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 + R13 Roof Attic (W) 1,054.6 X 0.0194X 56.0 = 1,147 R-21 Wall (W 21.2x6.16) (E) 156.0 X 0.0690 X 32.1 = 346 New R-21 Wall (E) 160.0 X 0.0690 X 32.1 = 355 R-21 Wall (W 21.2x6.16) (S) 70.0 X 0.0690 X 27.1 = 131 R-21 Wall (W 21.2x6.16) (W) 278.2 X 0.0690X 32.6 _ - 625 New R-21 Wall (W) 64.0 X 0.0690 X 32.6 = 144 R-21 Wall (W 21.2x6.16) (N) 255.0 X 0.0690 X 29.0 = 510 "R-0 Interior Wall 224.0 X 0.3560 X -2.0 = -159 X X = Page Total 3,098 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 55 (E) 19.1 X 20.7 + 60.9 X 37.2 = 2,663 59 (E) 19.1 X 20.7 + 60.9 X 37.2 = 2,663 New 19.9X2 (W) 39.8 X 17.0 + 0.0 X 31.9 = 679 New 12X2 (W) 24.0 X 17.0 + 0.0 X 31.9 = 409 X + X = X + X = X + X = X + X = X + X - Page Total 6,413 Internal Gain Btulhr Occupants 3.2 1 Occupants X 245 Btuh/occ. - T75 Equipment 1,054 I Floor Area X 0.50 w/sgft _ 1,799 Infiltration: 1.064 X a.87 X 53.14 X 34 = 1,665 Air Sensible C F M ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,749 Latent Gain Btu/hr Occupants 3.2 Occupants X 155� Btuh/occ. - 490 Infiltration: 4,771 X 0.87 X 53.14 X 0,00276 = 606 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 490