Loading...
04-6144 (SFD) Structural Calcs4e CALCULATIONS A CUSTOM RESIDENCE FOR: FLORES DE MONTANA STRUCTURAL C .1 OF 22 2/14/05 cffy OF LA A BUILDING & SAFETY DEPT. APPROVED FDR CONSTRUCTION OA itLl-l- BY A CUSTOM RESIDENCE FOR: HAROLD ANSCHEL 1-71A FLORES DE MONTANA LOT 7 - W-coltir lacmemotwo tEl1�R NiD fL(HiD TO S';rs�)'!! C�! �l � A?� W'sT10 HG CGDE k:S gotlTi2 VMS LA QUINTA, CALII � ¢ ; Lq!n PEh trT Pm f•';�E. PON3 !3 . `r- "" t7 SUSIEGT TO G jn.WS'NOTW'? WTHE Ei = LETTER 'Al 2 5 2005 �Toi it "RAI ®NLS' CHARLES D. GARLAND, LICENSE N., 11991. EXP EFRAIN F_ ARDENASD, MAR 2 20D5 By l 3 CALCULATIONS 2 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 LOAD...............................:.................. Page. 3 BEAM...................................................... Page 4 COLUMN....., ........................................ Page 6 LATERAL ANALYSIS .................. Page 7 SEISMIC ZONE, ......................... Page 8 SHEAR WALL REQUIREMENTS... Page 18 FOUNDATION ................ ............Page 19 1' CALCULATIONS A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 LOADS : ROOF EXTERIOR WALLS: PSF WOOD STUDS = PSF 1/2 GYRBD.2SIDES = PSF INSULATION = 2 WOOD STUDS = 2 TILE = 9 1/2" GYP BD. = 2 SHEATHING = ' 1 7/8" STUCCO = 10 RAFTERS = 2 INSULATION= 1 INSULATION = 1 GYP. BD. = 6 D.L.= 15 PSF D. L _ 19 L. L = 16 TOTAL LOAD = 35 PSF INTERIOR WALLS: PSF WOOD STUDS = 2 1/2 GYRBD.2SIDES = 3 INSULATION = 2 D.L= 7 PSF 30 F 22 2/14/05 t j CALCULATIONS A CUSTOM RESIDENCE FOR: FLORE'S DE MONTANA LOT 7 BEAM DESIGN HDR. SPAN = 8.0 ft TRIB. AREA = 15.0 ft D1= 19:0 Ib/ft L. L 20.0 Ib/ft TOTAL 39.0 Ib/ft' DOUGLAS FIR -LARCH No 1= Fb = 1000 psi Fv = 95 psi E = 1700000 psi Load Factor Co = Wet. Service Factor CM = Tem peratu re, Factor Ct Size Factor CF = Repetitive m. Fact. Cr = Incising Factor Ci = Shear stress Factor CH _ 585' Ib/II e:oo n BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) F'b = 1250 psi Req'd S = M'/ F'b S= 44.93 in"3 f b = M/S ALLOW F'b = ACT. f b 1250 psi > 678.8 psi SHEAR F'v = Fv(CD)(CM)(Ct)(CH) f v = 1.5 V / A F `v = 119 psi > f v = 67.1'8 psi DEFLECTION 5WL L^4 = 0.08 in 384 E` I E'= E (CM)(C)(C) 1700000 psi d'max = L/240 0.40 in 1.25 1,00 1:00 1.00 1.00 1.00 1.00 W = 585.0 Ib/ft M=WxL2/8 M= 4686.0 ft -1b M= 56160 in -Ib V=WxL/2 V= 2340 lb 4 OF 22 2'/14/05 USE 6 X 10 Area, = 52.3 in"2 Section= 82.7 in^3 Moment of Inertia= 393 in^4 OK OK OK BEAM 6X 10. .'I I CALCULATIONS 5 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 BEAM DESIGN HDR 2. SPAN = 6.0 ft TRIB. AREA = 15.0 ft Dl = 19.0 Ib/ft Ll = 20.0 Ib/ft TOTAL 39.0 Ib/ft DOUGLAS FIR -LARCH No 1= Fb = 1000 psi Fv = 95 psi E = 1700000 psi Load . Factor Co = 1.25 Wet. Service Factor Cm = 1.00 Temperature Factor Ct = 1.00 Size Factor CF '= 1.00 Repetitive m. Fact. Cr = 1.00 Incising Factor Ci = 1.00 Shear stress Factor CH = 1.00 W = 585.0 Ib/ft SOS cart 8.00 rt BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Q) F'b = 1250 psi Req'd S = M / F'b S= 25.21 in43 f b = M/S ALLOW F'b = ACT. f b = 1250 psi > 612.7 psi SHEAR F'v = Fv(CD)(CM)(Ct)(CH) fro= 1.5 V / A F'v = 119 psi > f v- 63.82 psi DEFLECTION M= WxL'/8 M= 2632.5 ft -lb M= 31590 in -Ib V=WxL/2 V= 1755 Ib USE 6 X 8 Area= 41'.3 in"2 Section= 51.6 in^3 Moment of Inertia= 193 in^4 OK OK 5WLL^4 = 0.05 in 384 E' I OK E'= E (CM)(G)(C) 1700000 psi BEAM 6 X 8 d max = L / 240 = 0.30 in t CALCULATIONS 6 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 BEAM DESIGN HDR 3 SPAN = 8.0 ft TRIB. AREA = 17.0 k D.L = 19.0 Ib/ft Ll = 20.0 Ib/ft TOTAL 39.0 Ib/ft DOUGLAS FIR -LARCH No 1= Fb: = 1000 psi Fv = 95 psi E = 1700000 psi Load Factor Co = Wet. Service Factor CM = Temperature Factor Ct = Size Factor Cr Repetitive m. Fact. Cr = .Incising Factor Ci = Shear stress Factor CH = W3 IbM IE 8.00 ft BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) F'b = 1250 psi Req'd S = M / F'b S= 50.92 in^3 f b = M/S ALLOW F'b = ACT. f b = 1250 psi > 769.3 psi. SHEAR F'v = Fv(CD)(CM)(Ct)(CH) - f v = 1.5. V / A F'v = 119 psi > f = 76.13 psi DEFLECTION 1.25 1.00 1.00 1.00 1.00 1.00 1.00 W = 663.0 Ib/ft M= WxL2/8 M= 5304.0 ft -Ib M= 63648 in -Ib V=WxL/2 V= 2652 lb USE 6'X 10 Area= 52.3 in"2 Section= 82.7 iin^3 Moment of -inertia= 393 in^4 OK OK 5WL L^4 0.09 in 384 E' I OK E'= .E (CM)_(C<)(Q) 1.700.000 psi BEAM 6 X 10 d max- L/240 = 0.40 in w CALCULATIONS 7 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 BEAM DESIGN BEAM 1 SPAN = 48.0 ft TRIB. AREA = 8.0 ft D.L = 19.0 Ib/ft Ll = 20.0 Ib/ft TOTAL 39.0 lb/ft DOUGLAS FIR -LARCH No 1= Fb = 1.000 psi Fv = 05 psi E = 1700000 psi Load Factor Co = Wet. Service. Factor CM = Temperature Factor Ct = Size Factor CF Repetitive m. Fact. Cr Incising Factor Ci Shear stress F.actorC, _ 312 IWMI NE 18.00 ft BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Q) F'b = 1250 psi Req'd S = M /F'b S= 121.31 in"3 f b = M/S ALLOW F'b = ACT. f b = 1250 psi > 907.4 psi SHEAR F'v = FV(CD)(CM)(Ct)(CH) f v = 1.5 V / A F'v = 119 psi > f v = 56.73 psi DEFLECTION 5WL L^4 0.38 in. 384 E' I E'= E (Cw)(G)(C) 1700000 psi. d max = L / 240 = 0.90 in 1:25 1.00. 1.00 1.00 1.00 1.00 1.00 W- 312.0 Ib/ft M=WxL2/8 M= 12636.0 ft -Ib M= 1.51632 in -Ib V=WxL/2 V= 28081b USE 6 X 14 Area= 74,3 in^2 Section= 167 in"3 Moment of Inertia= 1128 in"4 OK OK OK BEAM 6X 14 CALCULATIONS a OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/11/05 BEAM DESIGN BEAM 2. SPAN = 9.0 ft TRIB. AREA = 12.0 ft Dl = 19.0 Ib/ft Ll = 20.0 Ib/ft TOTAL 39.0 Ib/ft DOUGLAS FIR -LARCH No 1= Fb = 1000 psi Fv = 95 psi E = 1700000 psi Load Factor Co = Wet. Service Factor CM = Temperature Factor Ct Size Factor CF = Repetitive m. Fact. Cr = Incising Factor Ci = Shear stress Factor CH = 46& fibre 9.00 n BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) F'b = 1225 psi Req'd S = M / F'b S= ALLOW F'b = 1225 psi 46.42 in^3 f b = M/S ACT. f b = > 469.2 psi .SHEAR F'v = Fv(CD)(CM)(Ct)(CH) f v = 1.5 V / A F'v = 119 psi > f v = 49.94 psi DEFLECTION 1.25 1.00 1.00 0.98 1.00 1.00 1.00 W = 468.0 Ib/ft M= Wxv/8 M= 4738.5 ft -Ib M= 56862 in -Ib V=WxL/2 V= 2106 Ib USE 6 X 12 :Area= 63.3 in^2 Section= 121 in^3 Moment of Inertia= 697 in^4 OK OK 5WL L^4 0.06 in 384 E' I OK E'= E (Cm)(Ci)(Ci) 1700000 psi BEAM 6 X 12 d max = L /240 = 0A5 in CALCULATIONS A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 BEAM DESIGN BEAM 3 SPAN = 24.0 ft TRIB. AREA = 6.0 ft DOUGLAS FIR -LARCH No 1= Fb = 1,000 psi Fv = 95 psi E = .1700000 psi' SHEAR F'v = FV(CD)(CM)(Ct)(CH) f v = 1..5V / A F'v = 119 psi > fro = 56.73 psi OK DEFLECTION 5WL L"4 = 0.91 in 384 E' I OK E'= E (C.)(0)(0) 1700000 psi BEAM 6 X 14 d max = L./ 240 1,20 in 9OF22 2/14/05 Load Factor Co = 1.25 Wet. Service Factor CN = 1.00 D.L = 19.0 Ib/ft Temperature Factor Ct = 1.00 Ll = 20.0 Ib/ft Size Factor CF = 0.98 TOTAL 39.0 Ib/ft Repetitive m. Fact. Cr = 1.00 Incising Factor Ci = 1.00 Shear stress Factor C. = 1.00 W = 234.0 Ib/ft M=WxL=/8 2341bM M= 16848:0 ft -Ib M= 202176 in -1b V= W x L./ 2 24.00 n BENDING V= 2808 lb F'b = Fbx(CD)(CM)(Ct)(CF)(Gr)(Ci) F'b = 1225 psi USE Req'd S = M / F'b S= 1.65.04 in"3 6X 14 Area= 74.3 in"2 f = M/S Section= 167 in^3 ALLOW F'b = ACT. f b = Moment,of Inertia= 1128 in"4. 1225 psi > 1209.9 psi OK SHEAR F'v = FV(CD)(CM)(Ct)(CH) f v = 1..5V / A F'v = 119 psi > fro = 56.73 psi OK DEFLECTION 5WL L"4 = 0.91 in 384 E' I OK E'= E (C.)(0)(0) 1700000 psi BEAM 6 X 14 d max = L./ 240 1,20 in 9OF22 2/14/05 CALCULATIONS A CUSTOM RESIDENCE FOR FLORES DE MONTANA LOT 7 BEAM DESIGN BEAM #4 SPAN = 8.0 ft SPAN 2 = 4.0 ft. TRIB. AREA = 4.0 ft DOUGLAS FIR -LARCH No 2= Fb = 1000 psi Fv = 95 psi E = 1700000 psi Load Factor CD= 1.25 P= 650 Ib Wet: Service Factor CM = 1.00 Dl = 19.0 Ib/ft Temperature Factor Ct>= 1..00 L, L = 20.0 lb/ft Size. Factor CF = 1.00. TOTAL 39.0 Ib/ft Repetitive m. Fact. Cr = 1.00 Incising Factor Ci = 1.00 Shear stress Factor CH = 1.00 P 1 159 Wit M1 Q. M2 8.00 A 4.0 __> BENDING F`b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) F'b = 1250 psi Req'd S = M / F'b S= 14.06 in"3 M= 17576 f b = M/S ALLOW F'b _ ACT. :f b = 1250 psi > 212.5 psi SHEAR F'v = Fv(CD)(CM)(Ct)(CH) f v = 1.5 V / A F'v = 119 psi > f v = 41.05 psi W = 156.0 Ib/ft M1= 702.0 ft -Ib M1= 8424 in -ib M2= 1248 ft -1b M2= 1497.6 in -Ib M(p)= 2600 in -Ib V= 780 lb V= 650 lb 'USE 6 X 10 Area= 52.3 in"2 Section= 82.7 in^3 Moment of Inertia= 393 in"4 OK OK BEAM 6X 10 10 OF 22 2/14/05 CALCULATIONS A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 BEAM DESIGN BEAM 5 SPAN = 16.0 ft TRIB..AREA = 1.3.0 ft D.L = 19.0 Ib/ft Ll = 20.0 Ib/ft TOTAL 39.0 Ib/ft DOUGLAS FIR -LARCH No 1= Fb = 1000 psi 501 ILMI 18.00 rt BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) F'b = 1225 psi Req'd S M / F'b S= 158.93 in"3 f b = M/S ALLOW F'b = ACT. f b = 1225 psi > 1165.1 psi SHEAR F'v = Fv(CD)(CM)(Ct)(CH) f v 1..5 V / A F'v = 119 psi > f v = 81.94 psi DEFLECTION 5Wc L^4 = 0.39 in 384 E' I E'= E (CM)(G)(CI) 1700000 psi d max = L./ 240 = 0.80 in M= WxL2/8 M= 16224.0 ft -Ib M= 194688 in -Ib V=WxL/2 V= 4056 lb USE 6 X 14 Area= 74.3 in"2 Section= 167 in"3 Moment of Inertia= 1128 in"4 OK CSI 1 OK BEAM 6X 14 11 OF 22 2/14/05 Fv = 95 psi E = 1700000 psi Load Factor Co = 1.25 Wet. Service Factor CM = 1.00 Temperature Factor Ct = 1.00 Size Factor CF = 0.98 Repetitive m. Fact. Cr = 1.00 Incising Factor Ci = 1.00 Shear stress Factor CH '= 1.00 W = 507.0 Ib/ft 501 ILMI 18.00 rt BENDING F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) F'b = 1225 psi Req'd S M / F'b S= 158.93 in"3 f b = M/S ALLOW F'b = ACT. f b = 1225 psi > 1165.1 psi SHEAR F'v = Fv(CD)(CM)(Ct)(CH) f v 1..5 V / A F'v = 119 psi > f v = 81.94 psi DEFLECTION 5Wc L^4 = 0.39 in 384 E' I E'= E (CM)(G)(CI) 1700000 psi d max = L./ 240 = 0.80 in M= WxL2/8 M= 16224.0 ft -Ib M= 194688 in -Ib V=WxL/2 V= 4056 lb USE 6 X 14 Area= 74.3 in"2 Section= 167 in"3 Moment of Inertia= 1128 in"4 OK CSI 1 OK BEAM 6X 14 11 OF 22 2/14/05 CALCULATIONS 12 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 BEAM DESIGN BEAM: 6 SPAN = 9.00 ft dist. (a)= 5.00 ft dist (b)= 4100 ft P= 1400 Lb Dl 19.0 ib/ft L.L. 20:0 Ib/ft TOTAL 39:00 Ib/ft. TRIB.AREA = 10 ft DOUGLAS FIR -LARCH No 1= Fb = 1000 psi Fv 95 psi E, 1700000 psi LOAD FACTOR Co = 1:25 Wet. Service factor CM = 1.00 Temperature factor Ct = 1.00 Size factor CF = 1.00 Repetitive m. Fact. Cr = 1.00 Incising Factor Ci = 1.00 Shear stress Factor CH = 1.00 P= 1400 Ib W= 390.000 Ib/ft a b M= WxL'/8+Pab/I 4 --10, M1= 7059.9 ft -Ib 300 1b;2 M= 84718.3 in -Ib Rl= t R2= f V= R1= W L /2`+ Pb/L NE COO rt R1= 2377:22 Ib' BENDING V= R2= W L /2 + Pa/L F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci) R2= 2532.78' F'b = 1250 psi Req'd S = M / F'b S= 67.77 in^3' fb=M/S F'b,= 1250 psi > f b = 699.0 psi USE 6 X 12 Area= 63.25 inA2 Section= 121.2 in^3 Inertia= 697.1 in^4 OK' SHEAR F'v = Fv(CD)(CM)(Ct)(CH) f v = 1.5 V / A R= 2532.78 F'v = 119 psi > f V = 60:07 psi OK DEFLECTION 5WL 04 + Pa^2 b"2 = 0:0788 E= E (CM)(Ct)(C 1700000 psi 384 E'1 3 E I L d max = L /,2410.45 in OK BEAM 6 X 12. CALCULATIONS 13 OF 22 .A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 COLUMN DESIGN Column _ DOUGLAS FIR -LARCH No 2= Fc = 625 psi le = 10.0 ft E = 1600000 psi LOAD 5400 ib Load Factor Co = 1.25 Wet. Sery Factor CM = 1.00 TOTAL 5400.0 Ib Bucking Stiffeners Ct = 1.00 P Size Factor CF := 1.00 Incising Factor Ci = 1.00 KCE = 0.30 Buckling and Crushing Interaction c = 0.80 Fc* = .Fc(CD)(CM)(Ct)(CF)(Cr)(Ci) 10.00 Fc* = 781.25 psi USE Euler Critical Buckling Stress for Columns 4 X 6 Area = 19.3 in"2 d = 3.5 in FCE = KBE E = 408.3333 psi (le / d)^2 Column Stability Factor Cp= CP = 1 + FoE /Fc* — 1 +,F.IFc* 1 ^2 —FSE/'Fc* 2c 2c J c Cp = 0.44934 Pc = Fc (CP)(CD)(CM)(Ct)(CF)(Cr)(Ci) Pc = 351 psi P = F'c *A = 6757.59 OK P = 5400.0 COLUMN 4 X 6 CALCULATIONS A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 LATERAL FORCE ANALYSIS WIND: 80 mph Exposure C P = Ce Cq qs Iw Ce. = 1.06' 0'-1'5" Cq = 1.30' qs = 16.4e Iw = 1,.00 P 22.60 PsF WIND LOAD= 225.992 # ft SEISMIC ZONE:4 SOIL PROFILE. TYPE ASSUMED: SD SEISMIC SOURSE TYPE: A DISTANCE TO SEISMIC SOURSE 10 KM Na = 1.0 I= 1.0 Nv= 1.2 Ca = 0.44 Z = 0:4 R= 5.5 Cv = 0.8 V = 2.5Ca NV/R = V=CvIW/RT= V=0.11 CaIW 0.20 W (30 - 5) 0.18 W (304) 0.05 W (30-6) V = 0.8 Z Nv I W/R = 0.07 W (30-7) V = 0.20 VV 14 OF 22 2/14/05 CALCULATIONS 15 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 UNIFORM BUILDING CODE 1997 MAPS OF KNOWN ACTIVE FAULT NEAR SOURCE ZONE IN CALIFORNIA Contours of closest horizontal distance to known seismic sources CALCULATIONS 16 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 SEISMIC (CONTINUED) D:L. ROOF 19 psi SEISMIC, V,= 0.20 DIAP H=43)62 DIAPH=24X54 EXT. WALLS 15 psi WALL HT = 10i ft TRANSVERSEL LONGITl.1I3INAL WORST 43 FT WORST 62 FT ROOF= 817 ROOF = 1178 2 Walls = 150 2 Walls= 150 967 1328 X 0.2 X 0.2 193 # ft (MAX) 266 # ft (MA)) SEISMIC =266 PLF > 225:99 = WIND W= 266 T=C = WLA 18b L= 62 = 2967.926 B=43 NAIL = TABLE 23 -III -C=2 TOTAL NAIL = LOAD /NAIL= 15.8 PROVIDE (8 PAIR)16 d COMMON E.A 4'-0" SPACE @ TOP CHORDS e � • SHEAR WALL REQUIREMENTS FT ROOF D.L. = 19 WALL HT,1 = 10 WALLS D.L. _ 15 r.FORG. AREA TOTAL FO TRIF) BPICE (Ft.) (LB) 266 20 5320 266 20 5320 266 20 5320 266 8 2128 266 82128 18 266 16 4256 266 16 4256 266 16 4256 266 22 5852 266 10 '2660 266 22 5852 268 22 5852 266 22 5852 266 22 5852 266 25 6650 268 25 6650 266 12 3192 266 12 3192 266 12 3192 266 12 3192 266 12 3192 266 12 3192 266 10 2560 266 10 2660 266 20 5320 266 20 5320 266 20 5320 266 8 2128 266 8 2128, 266 23 6118 266 10 2660 266 11 2926 266 11 2926 CALCULATIONS A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 37 8 144 37 16.5 144 12 6 177 12 6 177 18 5.5 236 18 6 236 18 6.5 236 20.5 20.5 285 12.5 12.5 213 26 12.5 225 26 4 225 26 4 225 26 5.5 225 29 9.5 229 29 19.5_ 229 8 2 399 8 2 399 8 2 399 8 2 399 12.5 12.5 255 16.5 16.5 193 12:5 8.5 213 12.5 4 213 33.5 11 159 33.5 8.5 169 33.5 14 159 10 5 213 10 5 213 25 25 245 11.5 11.5 231 6 3 488 6 3 488 17 OF 22 2/14/05 E N UPLIFT FORMULA oc M42/d (wb LA2/2)+(yVwL/2)))!t I I MAx I SPA" Nf LOAD (V) (b)UPLIFT. FORS SFEAR VYALL NALL- SEG 8 # TYPE 1797 20 -204 1 1150 20 369 1 2372 20 -713 1 '1064 8 1418 1 1064 8 1418 1 1306 16 1754 1 '1419 16 1703 1 1537 16 1652 1 5852 22 -66 2 2660 8 1441 1 2813 22 450 1 900 22 1840 1 900 22 1640 1 1238 22 1430 1 2178 18 1154 1 4472 18 256 1 T98 8 3838 798 8 3838 STHD14 798 8 3838 798 8 3838 STHD14 3192 12 1549 1 3192 12 624 1 1809 8 1645 1 851 8 1874 .1. 1747 10 838 1 1350 10 997 1 2223 10 647 1 1064 8 1823 1 1064 8 1823 1 6118 23 -1263 1 2660 24 506 1 1463 25 4349 1463 26 4330 17 OF 22 2/14/05 E N RVVALLSS oc I I MAx I SPA" Nf 48 48 48 STHD14 POST 4X6 48 STHD14 POST4X6 48 STHD14 POST4X6 48 STHD14 POST 4X6, 48 STHD14 POST4X6 48 32 STHD14 POST 4X6 48 48 STHDI4 POST4X6 48 STH1314 POST4X6 48 STHD14 POST4X6 48 STHD14 POST4X6 48 48 SM 24x8 SM 24x8 SM 24x8 SM 24x8 STHD14 POST 4X6 48 48 STHD14 POST'06 48 STHD14 POST4X6 48 48 48 48 STHD14 POST4X6 48 STHD74 POST4X6 48 48 48 SM 36X SAA 36X CALCULATIONS 18 OF 18 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 CALCULATIONS 19 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2i1'4i05 UPLIFT FORMULA: (Vh-(2/3 (wb L"2/2)+(WWU2)))/ L WALL Vh Wb 2/3(WbL"212) WWU2 (b) FORCE No. 111503' 380 I I I ft JUPLIFT. # H 1 IV (J 3tsu 19591 938 2U -204 A 111503' 380 8147 600 20 369 A 23724 380 34657 1238 20 -713 B 10640 152 1833 450' 8 1418 B 10640 152 1833 450 8 1418 G 13004, 304 3081 413 16 1754 C 14187 304 3666 450 16 1703 C 15369 304 4303 488 16 1652 D 58520 418 58848 1.538 22 -66 E 26600 152 7956 938 8 1.441 F 28135 418 21,880' 938 22 450 F 9003 418 2240 300 22 1640, F 9003 418 2240 300 22, 1640' F 8665 418 .4236 289 22 1430 G 15249 342 10340 499 1'8 1154 G 31301 342 43,565 1,024 1.8 256 H 5586 152 204 105 8 3838 H 5586 152 204 105 8 3838 H 5586 152 204 105 8 3838 H 5586 152 204 105 8 3838 1 22344 228 11934 656 12 1549 1 22344 228 20794 '866 12 624. K 12662 152' 3679 446 8 1645 K 5958 152 815 210 8 1874 L 12228 190 7702 578 1.0 838 L 9449 190 4599 446 10 997 L 15563 190 12475 735 10 647 M 7448 152 1273 263 8 1823 M 7448 152 1273 263 8 1.823 N 42826 437 91497 131.3 23 -1263 O 18620 456 20203 604 24 506 P 1024.1 475 1432 158 25 4349 P 10241 494 1489 158 26 4330 CALCULATIONS 20 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 SHEAR FALL CONSTRUCTION D 1/2" GYPSUM WALL; BOARD APPLIED DIRECTLY TO 2z STUDS WITH STANDARD WALL BOARD NAILS (1? " x .086" DIAMETER w/ 9/32" HEADS) OR,5d COOLER NAILS (1?"x .086" DIAMETER wl 15/64" HEADS) AT 7" O/C. MAX. TO ALL STUDS, SILLS, PLATES AND BLOCKING. ANCHOR w/ ? " DIAMETER x 10" LONG ANCHOR BOLTS.(wl 2"x 2" x 3/16" THICK PLATE WASHERS BETWEEN NUT AND WOOD SILL) @ 6'-0" O/C MAX. (ALLOWABLE LOAD: 50 riff - PER UBC TABLE 25.1-1997 UBC) 1*7/8" PORTLAND CEMENT PLASTER ON WOVEN WIRE OR EXPANDED METAL LATH NAILED AT EACH STUD, SILL AND PLATE @ 6" O/C MAX. wl No. 11 x 1'/2" GALVANIZED NAILS WITH 7/16' DIAMETER HEADS OR ATTACHED w/ No. 16 GAUGE STAPLES HAVING 7l8" LONG LEGS. ANCHOR w/ ? " DIAMETER x 10" LONG ANCHOR BOLTS (w/ 2" x 2" x 3/16" THICK PLATE WASHERS BETWEEN NUT AND WOOD SILL) @ 48" OICMAX. (ALLOWABLE LOAD: 180 pif —.PER UBC TABLE`25-1-1997 UBC) THE NEXT THREE (3) SHEAR WALL TYPES SHALL ALL HAVE THE FOLLOWING IDENTICAL STRUCTURAL WOOD PANEL DIAPHRAGM: (WALL1 ,'2 & 3 ONLY) D 318" COX APA PLYWOOD OR 3/8" ORIENTED STRAND BOARD APPLIED DIRECTLY TO THE STUDS, WITH THE LONG DIMENSION OF FULL PANELS LAID PARALLEL OR PERPENDICULAR TO THE LENGTH OF THE STUDS, ALL EDGES OF EACH PANEL SUPPORTED ON STUDS, SILLS, PLATES OR BLOCKING AND NAILED AND ANCHORED AS FOLLOWS: 1 D 8d COMMON NAILS @ 6" OIC AT ALL PANEL. EDGES' AND 8d COMMON NAILS @ 12" O/C AT ALL FIELDS. ANCHOR WITH' 5/8" DIAMETER BY 10" LONG ANCHOR BOLTS AT 48" 0/C. (ALLOWABLE LOAD: 160 If —PER UBC TABLE 23.11-1.1 FOOT NOTE'No. 4 —1997 UBC) CONSTRUCTION NOTE(S) 1 & 2 APPLY (NOTES 3,4 AND 6 APPLY WHEN DIAPHRAGM AT BOTH,SIDES) 2 D 8d COMMON NAILS @ 4" 0/C AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" O/C,AT ALL FIELDS. ANCHOR WITH 5/8" DIAMETER ANCHOR BOLTS AT 32" O/C.. (ALLOWABLE LOAD: 380 plf— PER UBC TABLE 23-II.1-1; FOOTNOTE No. 4 —1997 UBC) CONSTRUCTION' NOTE(S) 1 & 2.APPLY (NOTES 3, 4, 5 AND6 APPLY WHEN DIAPHRAGM AT BOTH SIDES) D 3 8d COMMON. NAILS @ 3" OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" O/C AT ALL FIELDS. ANCHOR WITH'/," DIAMETER BY 12" LONGANCHOR BOLTS AT 32" O/C. (ALLOWABLE LOAD: 490 pIf - PER UBC TABLE 23.11.1-1; FOOT NOTE No. 4 —1997 UBC) CONSTRUCTION NOTE(S) 1, 2, 3 & 6 APPLY (NOTES 4 & 5 APPLY WHEN DIAPHRAGM AT BOTH SIDES) w CALCULATIONS 21 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2i14i05 4 D 15/32" STRUCT. I APA PLYWOOD OR 15/32' ORIENTED STRAND BOARD (OSB) APPLIED DIRECTLY TO THE STUDS, WITH THE LONG DIMENSION OF FULL PANELS PARALLEL OR PERPENDICULAR TO THE LENGTH OF THE STUDS, ALL. EDGES SUPPORTED ON STUDS, SILLS, PLATES OR BLOCKING AND NAILED AND ANCHORED AS FOLLOWS: 8d COMMON NAILS @ 2'12" O/C AT ALL PANEL EDGES AND 8d COMMON NAILS@ 12" OIC AT ALL FIELDS. ANCHOR WITH Y." DIAMETER ANCHOR BOLTS AT 16" OIC. (ALLOWABLE LOAD: 730 Of — PER UBC TABLE 2341-1.1-1997 UBC) CONSTRUCTION NOTE(S) 1, 2, 3, & 6 APPLY (4 AND 5,APPLYWHEN DIAPHRAGM AT BOTH SIDES) CONSTRUCTION NOTES! 1 SEISMIC ZONE 4: 2 x 2" x 3116' PLATE WASHERS SHALL BE PROVIDED BETWEEN ALL ANCHORBOLT NUTS AND THE WOOD SILL. 2 SEE ANCHOR BOLT CALCULATIONS FOLLOWING THESE NOTES'IN THE.CALCULATIONS:, 3 EDGE NAILING AT ABUTTING?ANEL EDGES FOR WALLS LOADED IN EXCESS OF 3.50 pif SHALL BEAPPLIED TO 3x OR WIDER STUDS. 4 APPLYING EQUAL THICKNESS STRUCTURAL WOOD PANELS TO BOTH STUD FACES OF A SHEAR WALL AND WITH, MATCHING NAILING FOR BOTH SIDES SHALL PROVIDE DOUBLE THE LOAD,CAPACITY OF WALLS HAVING THE SAME PANELS AND NAILING.APPLIED TO ONLY ONE FACE. 5 STRUCTURAL WOOD PANEL SHEAR WALLS WITH PANELS APPLIED TO BOTH FACES AND WITH EDGE NAILING LESS THAN 6' OIC SHALLHAVE ABUTTING PANEL EDGES FOR ONE SIDE OFFSET ONE STUD SPACE FROM THE OTHER SIDE (NOTE No. 3 ALSO APPLIES) 6 ALL SHEAR WALLS HAVING A LOAD CARRYING CAPACITY IN EXCESS OF 350 plfSHALL BE PROVIDED WITH 3x P,T:D.F. SILL PLATES AND 12' LONG ANCHOR BOLTS OF THE DIAMETER PROSCRIBED FOR THAT WALL CONSTRUCTION TYPE (ALL ANCHOR BOLTS SHALL BE SET T INTO CONCRETE) 7 WHERE THE CONTRACTOR DESIRES TO CONSTRUCT THE SLAB -ON -GRADE AND THE FOOTINGS AND FOUNDATION IN A TWO POURSYSTEM, ALL ANCHOR BOLTS SHALL HAVE A MINIMUM LENGTH OF 14", SETTING THEM A MINIMUM OF 4" INTO THE TOP OF THE FOUNDATIONS BEFORE POURING THE SLAB. 8 ALL ANCHOR BOLTING, HOLDOWN BOLTS OR STRAPS AND OTHER FORMS OF CONCRETE INSERTS SHALL BE SECURELY HELD IN PLACE WITH JIGS OR OTHER SUCWDEVISES PRIOR TO REQUESTING FOUNDATION INSPECTION, DURING INSPECTION_ AND DURING ACTUAL POURING OF CONCRETE. 9 ALL ANCHOR BOLTS AND HOLDOWN. BOLTS SHALL BE BROUGHT PLUMB PRIOR TO THE CONCRETE HARDENING. MECHANICAL STRAIGHTENING OF BOLTS AFTER THE CONCRETE HAS,HARDENED THAT RESULT&IN SLAB EDGE'BREAKING SHALLRESULT IN REJECTION OFA PORTION OF THE SLAaAND'FOUNDATION BY THE ARCHITECT OR STRUCTURAL DESIGNER OF RECORD'AS HE DEEMS NECESSARY, IT'S REMOVAL ANDAEPOURING OF THAT PORTION OF THE CONCRETE. 10 HOLDOWN STRAP HOOKS SHALL BESTABLIZED DURING THE CONCRETE POUR IN ORDER TO ENSURE THEY REMAIN AT THE MANUFACTURER'S PROSCRIBED ANGLE OF INSERTION. n ATTACHMENT OF A 3x SILLPLATE TO FLOOR FRAMING BELOW SHALL BE MADE WITH THE USE OF SIMPSON.SDS'Y.x6 WOOD SCREWS AT 3' o/c. 12 ATTACHMENT OF A 2x SILL PLATE TO FLOOR FRAMING BELOW SHALL BE MADE WITH THE USE OF 16d @ SPACING INDICATED.AT'THE SHEAR WALL TABULATION. CALCULATIONS 22 OF 22 A CUSTOM RESIDENCE FOR: FLORES DE MONTANA LOT 7 2/14/05 FOUNDATION SOIL PRESSURE = 1000 PSF LOADING ROOF = 35 EXT. WALLS = T5 H-1 = 10 ft TYPICAL PERIMETER FOOTING AT 1 STORY Tdb. Area (it)= 15 LOADING.: ROOF = 525 #1 WALL = 150 #1 W'= 675 #1 'REQ'D WIDTH 0.675 FT/ FT LENDTH 1.2" WIDE x 12" CONTIN PERIM FT, AND 2 # 4 BARS, CONTIN . FOOTING FOR POSTU4 LOADING: W= 3600 Ib AREA = 3.60 sf 24" SQ x12" THK FOOTING WI 4- # 4 EA.WAY cimrdoli 3. Garkndii ArahiWn: - PACE,- z 3.", 2� oft Palm Dr., Sutto 4 DATE: d City, CA =34 For.. 7-V Ak V2 I 4-Lh Gine— vy Q0. 19,G) ur- C. Gsdando alla Palm Dr., Su.' DATE. Catr%e4fsa: I C7dy, CA M34 kakdws For. .... ......... . 3o —times % VO I 2,j ." . , I IV %.067fts give' W, ^M411IMMS, 35-325 Date Palm Dr., Suite 151-J Cathedral City, CA 92234 Stractuml Cakubtlons For. DAM. I PAW: run LA ---> LAT. WALL LWNC, A= '.46 2-b - -6Df C 16 I OT= L.V-T ----------- 2 - ----- Val Oc) -1 Ac 14 ( A(�) -71 o V, Chades D. Gadand, ArchN act 35-325 Date palm Dr., Stfda 15114 Cathedral City, CA 92234 Stractund Cakuktions For. 00 0ow ��AOv �kkAM_ o 14 q PAGE: