Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2016-0107 Title 24
aFF1W Iropv RICK 8"U U F -U TITLE 20, INC. 7544 SADDLEHILL TRAIL, ORANGE, CA 92869 - (714) 771-1507 - FAX (714) 771-2939 • T-24@socal.rr.com Owner: Lennar Homes/Corona 980 Montecito Drive, Suite #302 Corona, CA 92879 Designer: The McKinley Associates, Inc. 1818 First Avenue San Diego, CA 92101 Project: Belmont Collection Plan 2 Reverse (Lot 148) La Quinta, California Job No. 12-13 April 15, 2016 APR 192016 COF��UNf� LA ��ONrq ®eVEL®PME►ur CITY OFLA --- BUILDING & QUINTA APPR TY DEPT. FOR CONS n�� uCTION DATER hq If, .STATEMENT OF CONFORMANCE These Calculations contain all the building features and performance specifications required for compliance by the California Code of Regulations Title 24, Part 1, Administrative Requirements; Part 6, Building Energy Efficiency Standards; and portions of Title 20, Appliance Efficiency Standards. When these features are incorporated into the architectural plans the design will be in compliance with the 2013 Energy Efficiency Standards as they apply in the specified Climate Zone for residential buildings using EnergyPro, a California Energy Commission approved computer performance method program. R08-90-243 & NR08-90-527 Prepared By: Ridk: Maurer Energy Plans Examiner Certificate No. R08-88-1601 and NR08-88-3583 California State License No. 502290 C20 ** SUMMARY SHEET ** Pro'ect: .............................................. - Lennar._H.o.mes. - La..Quinta CA _ _ ........... Zone: _.15 "Belmont Collection" Plan.2 Reverse (Lot 148) Wall Insulation: R-15 in 2x4 Exterior Walls R-21 in 2x6 or Greater Exterior' Walls, Double Exterior Walls and Attic Knee Walls Ceiling Insulation: R-38 Typical Radiant Foil Barrier: Required @ Roof o/Conditioned Space & Attic Gable Ends (Requires an Emittance of 0.05 or less) Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Emissivity Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with High Performance Low -E Glass. (See Notes) Hard Surface Flooring:. None Required Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 35,872 BTUH Minimum AIC SEER: 14.0 SEER/11.7 EER Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: Min.Sens.= 44,984 @ 115° (A/C:Size By Mechanical Contractor) Duct Insulation: R-8.0 For Ducts & Plenums in Unconditioned Spaces ` (Duct Leakage Test Required) Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. (HERS Verification Required) 3) This house will have a tankless water heater with an energy factor of .82 or greater and sized per the owner's specifications. 4) All windows and glass doors will have non-metal frames with high performance Low -E (Max) glass and the following maximum NFRC values: U -factor SHGC Operable .31 .23 Fixed .29 .25 .Glass Door .29 .23 Large Glass Door .32 .19 i3 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #2 Reverse (Lot 148) Belmont Collection La Quinta, CA Project. Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 E. Saddlehiil Trail Orange, CA 92869 714-771-1507 Job Number: .® Date: 4/14/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report, This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com:. :..Ener .. Pro 6.7 by. EneSof .. , User Number.. 1.686 !D ...: CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation Daterrime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xmi CFI R -PRF -01 Page 1 of 10 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Belmont Collection - Plan fit Reverse (Lot 148) 04 05 02 .._ Calculation Description: Title 24 Analysis ... .... .... Energy Use (kTDVifl2yr) 03 Project Locstlori BeiniontCoileGion Compliance Margin Percent Improvement 04 City La Quint.- 05 Standards Version Compliance 2015 06 Zip Code 07 ., ComplianceManagerVeislon' 13EMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 ` ` 09 ....... Software Version Energy Pro 6.6 10 Building Type Single Family 11 Front Orientation (deglCardlnal) 270 12 Project Scope 'Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 3153 15 Number of Zones 1 16 Slab Area (#2) 3153 17 Number of Stories 1 16 "' ' •.. "Addition Cond. Floor Area NIA 19 Natural Gas Available: Yes 20 Addition Slab Area.(82) .N1A 21 Glazing Percentage (%) 20.3% CQI P IAN 1tESl1LTS „„ .. . .. 01 Building Complies wltwc-rn inter f)orformine8 02 This'building InCotporatCs foaturei,,thAt ritqulro fiold fa9ting'Dndlor veriRcation by ardtrtffiIIG NEtt$ IatiY,un'Yfer the euparvislon of a CECapproved HERS provider. 03 This building Incorpora¢s:one Ot nt9re Speelal i-eatures stwvva: botfiw.,w„ - "gra fi $,.. t � M.� c � e. �.,,.5 L s ,..✓B' �,.:h. a Registration Number: 216-IJ0t41420A-0=00000-0000 Registration Date/Time: 2016-04.1514:36:49 HERS Provider: CaICERTS I-, CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016.04.1416:40:34 ENERGY USE SUMMARY 04 05 06 07 ol) ; Energy Use (kTDVifl2yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.32 1.56 -0,24 18,2% Space Cooling ... 97.67 t39.80 ... _ .. . . . .... 7.77 .. ... ....... 8.0% IAO Venlilalion 0.87 0.87 0,00 0,0% Water Heating 8.14 5.40 2.74 33.7% Photovoltaic Offset- 0.00 0.00 _ Compilence Energy Total 108.00 97.73 - 10.27 ' 9.5% Registration Number: 216-IJ0t41420A-0=00000-0000 Registration Date/Time: 2016-04.1514:36:49 HERS Provider: CaICERTS I-, CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016.04.1416:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 146) Calculation DatefTime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xm1 CC-oUnEb SPECIAL FEATURES 'ha following are features that must be Installed as condition for meeting the modeled energy perfcrmance for this computer analysis. Non-standard roof reflectance Window overhangs and/or Ons. . CF1R-PRF-01 Page 2 of 10 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a car0fied HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail Is provided in the building components tables below. Building -level Verifications: - - - IAO mechanical ventilation Cooling System Verifications: • Minimum Airflow • Refrigerant Charge Fan Efficacy Watts/CFM HVAC Distribution System Verifications: *. Duct Sealing Domestic Hot Water System Verifications: Recirculation, Demand Control Push ekw ENERGY OCSIGt BAYING *S is the sum of the annual TDV energy:ibnturmp0an far�anoigry;Sasr+ Crahp +nia i11c1Udad in bre petlomtancF const nae:appronrh:farti10 SlaMerd' Design Building (Energy Budget) and the annual TDV energy consumption for lighting and oolnpotlan! +Sot r0ulated by Till 2$ pit &'{sucfi as dtrrtsR ltappf D+)ces a Ftinsu+rior eiotiUbrtlt } lnif accounting for the annual TDV energy offset by an $s, y> ? .0 s3..s. on-site renewable energy system._, .. ... .. y... .. '.3_ w oferegee Ene_ y Use i s Elia tidal n Balt ` +B fir .... f! , n9: Margin g Percent Improvement ' Total Energy (kTDWf2 yr)• 149.10 138 83 t .' "` 10.27 Project Name 'includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 —.02 .... _ '03 04 05 06 07 07 :Number of Dwelling Zone Floor Area- (ft=) Number of Ventilation Number of Water Project Name Conditioned Floor Area (112) ' Units 'Number of Bedrooms Numhnr:o8?bries Cooling Systems Heating Systems Belmont Collection - Plan 42 3153 1 3 1 0 1 Reverse (Lot 148) �ZONE:INFORMATION � . . ... ......... .�������"' .. _...._. 01,.. ....... ....... .........02 ,. .__.. :.: ..:- 03 04 05 06 07 - Zona. Name Zone Typa HVAC System Name ............ .. Zone Floor Area- (ft=) Avg. Gelling Height Water Heating System 1 Water Heating System 2 House Conditioned HVAC1 3153 12 _ DHW Sys 1 Registration Number: 216-N0141420A-000000000-0000 Registration Date,fnme: 2016.04.15 14:36:40 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016.744 HERS Provider: CetCERTSInc, Report Generated at: 2016-04-14 16:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation Date/Time: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xml CF1 R -PRF -01 Page 3 of 10 OPAQUE SURFACES .. ._ ...__,.__ ,_....... 01 02 03 04 05 06. 07 `- OB Name Zone Construction Azimuth Orientation Gross Area (ft2) Window 8 Door Area (112) 'Jill: (deg) Front 2x6 Wall House R-21 Wail..- _ 270 Front..._. 490 ... "115 90 _ ...._ Right 2z6 Wail _ . House �• R7211 Wall 180 Right 671 110.5 90 Back 2xU UVa11 '' Hous© R-21 Wal' 90 Back 862 362 90 Left Wall House R-15 Wall 0 Left 100 90 Left 2x6 Wall House R-21 Wali 0 1-e8 500 80.4027 90 Front Garage Wall ........ House»_Garage_ . R-15 Wall HoussfGarage 50 0 Front 2x6 Garage Wall "": House»> Garage_ R-21 Wali HousefGamge 220 21 Back 2x6 Garage Wall House»_Garage_ R-21 Wail House/Garage 100 0 Knee Wall House»Attic House R-21 Knee Wall . - -..,, ,- .,., _ 190 0 ' Ceiling Below Attic House ;_ ,..: R-38 Attic 10# Radiant 3153 FG Wall.. . Garage—. . _ . a-0 �N013 . 270 Front 310 173 90 RG' Wall .. ::-Gara9s_ Rr . ��3aa T ";R -Q W?)' a i 180 �y .;2fµ-1 :a`. d 110 U 90 eG Wail 40'......_. - 0 80._. LG Wall {{ : Garetffaa a sem, R-0 Wa4 0'r Lel ( 220 0 90 Garage Ceiling _Garag _ ^• Yt-0°&arago'A`ai•. 818 ATTIC__ - .. ._ ...__,.__ ,_....... 01 02 03 _ 04 05 _. 06 .... _....07.,__... ...... 08 Name Construction type Roof Rise. Roof Reflectance Roof Emlttance Radiant Barrier Cool Roof Attic Garage_ Attic Gaia9e Roof Cans Ventilated' 3' 0.16 0.89 Yes No Attic House Attic RoolHouse Ventilated 3 0.16 0.89 Yes No Registration Number: 216-NO14142OA-000000000-0006 Registration Date/rime: 2016.04-1514:36:49 HERS Provider: C210ER7S Im CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016.744 Report Generated at: 2016-04-14 16:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation DaterTime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xml CF1 R -PRF -01 Page 4 of 10 WINDOWS Name Side of Building 01 02 03 04 05 ? 06 07 08 09 10 Name Type Surface (OdentationAzimuth) , Muitlpli -. Width (ft) Height (ft) er Area (ft2) - 11.1 -factor SHGC Exterior Shading Front Fixed _ . Window Front 2x6 Wall (Proof -270) 1.5 5.0 2 15.0 0.29 0.25 Insect Screen default (default) `FroiifOpeneble . ` Window Front 24 Wall (Front -270) 3,0 6.0 2 36.0 0.31 0.23 Insect. Screen (default) Front Openable 2 Window Front 2x6 Wali (Front -270) 3.0 6.0 2 36.0 0.31 ` 0.23 Insect Screen (default) Right Oponable Window Flight 2x6 Wali (Right -180) 6:0 .. 6.0 1 36.0 0.31 023 Insect Screen (default) Right Openab) e 2 Window „ Right 2x6 Wan (Right -180) ' """ 5.0 6.0 1 30.0 0.31 0.23 i Insect Screen (default) Right Fixed Window Right 2x6 Wall (Right -180) 5.0 1.5 1 7.5 0.29 0.25 Insect Screen (default) Right Openable 3 Window Right 2x6 Wali (Right -180) 4.0 5.5 1 ...22.0 " 0.31 0.23 insect Screen (de,<'autt} Right Openable 4 Window Right 2x6 Wall (Right -180) 2.5 6.0 1 15.0 0.31 0.23 Insect Screen (default) Back Glass Door Window . ;;, Back 2x6Wall (Back -90) 6.0 8,0 1 48.0 0.29 0.23 `. Insect Screen (default) Baric OpenatA6 Window y.. . % ;Sobk 2x6 Wail.(B3pt_g0}. 8.0 6.0 1 48.0 0.31 0.23 Insect Screen (default). -'Back Fixed Window m Eiack 2x0 Wall;(Back 90): 18.0 1.5 1. 27.0 0.29 025 Insect Screen (default) Back Glass Door 2 Window Salk 2.A 4�a11(Hadt�30)\ rte_ s ; 1Q pgq y : g 8.0 1 144.0 0.32 0.19 Insect Sween (default) Bark Fixed 2 Window Back 7.x6 Wail .96) jE a;=; �� 1(i:U 'Va 1.5 vlff% i 150: 0.29 0.25 Insect Screen (default) Back Glass Door 3 Windowcam Back?kS WPtt (Bacl ,+39}' � s ;; t ? ' 1Q 0' :8 0 a I :1 a�8f),53 0.29 0.23 Insect Screen (default) Left Openable Windowc 'left 2t(SyYefi;(LoR Ojx 2:0 '' '4O g u Yy 8.0 0.31 0.23 Insect Screen (default) Left Openable 2 Window Left 2x6-:Wall(L6f(-0) CO. 6.0 " 1 .30:0 0:31 0.23 Insect Screen (default) Left Glass Door Window Left 2x6 Wall(Left-0),2.7 8.0 1.002 21.4 0.29 0.23 Insect Screen (default) ..left Openable 3. _. ' Window Left 2x6 Wail (Lett -0) 2.5 6.0 i 1 15.0 0.31 023 Insect Screen (default} ODORS Name Side of Building Area (tt2) U4actor Front Door Front 2x6 Wall 28.0 0.50 Front Garage Door Fro it 2x6 Garage Wali ' " "' 21.0 0.50 Car Door "" FG Wall 173.0 0.50 Registration Number: 218 -1,10141420A -00000000M000 Registration Dateriime: 2016.04-15 14:36A9 HERS Provider: CeICERTS Inc. CA Building Energy Efficiency Standards • 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016.04-1416:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation Daterrime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xml CFI R -PRF -01 Page 5 of 10 OVERHANGSAND'FWS „.,..,. 1'-Ot � 02 - 03 1 04 j 05 06 07 08 09 11 12 13 � 14 • Overhang - - Left Fin :...... Right Fin. Window Depth.:, .,Dist, Up Leff Extent : Right Extent . Flap Ht. :. Depth Top Up Dis1L Bot Up Depth Top Up Dist R Sot Up _.._.. Front FixeO1 0.3 2 `' 2 0 0 0 0 0 0 0 0 0 Front Openable2 0.3 2 2 0 0 0 0 0 0 0 ... 0 0 Front Openable 2 2 0.3 2 2 0 ....- ..0 0 0 0 0 0 0 0 Right Openable 11 3 ... 2 2 0 0 0 0 0 0 0 0 0 Right Openabie 2' 1.5 :' 4 —2 2 0 0 0 0 0 0 0 0 0 Riglit Fixed. 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Right Openable 3 i,Si ,i 2 2 2 p 0 0 D C_ 0 0 _- 0 0 Right Openable 4 B ?:; : ..... 0 2 2 0 .. 0 0 0 0 0 0 0 0 Back Glass Door - .,, 15 �:< . 1.5 '. " 2 2 ' '.. 0 0 0 0 0 0 0 0 0 `BackOpenable - r::1.;5� ,„�1:5,._ 2 2 0 0 0 0 0 0 0 0 0 Back Fixed... 11 w 1 ? mete, spa€ x%Oa azo . s8 0., .. .0. 0 0... 0 0 ... 0 Back Glass Door 2 pal t 3 -mss 12.,•.0.`0 0 0.., 0 0 0 0 Badt Fixed.? . .. ... , t1 .: a. r 1 .... t r2 1 c €S 0 -d�,rrlu ri.3.,.«r., 0 0 0 0 0 Back Glass'Door 3 11 i, b2 W ry2 Cy 1'4. > 0- w 0 0 0 0, 0 Left Openable 1.5 2` 2 ; 2 0 ;0 0, 00 0 _ 0 0 0 Left Opanable 21.5 2. 2 2 0 0 ... ....0.... '. D 0 ... ........0 0 0 0 Glass Door . Left. 1:5 2 .., . 2 2. : 0 0 0 0 0 0 0 0 Left OpenabtB 3,: 6'` 0 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 216-NO14142OA-ODDODCGOD-0000 Registration Date/Time: 2016-04-1514:3G".49 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Ca10ERTS inc.. Report Generated at: 2016-04-1416:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Pian #2 Reverse (Lot 148) Calculation DatefTime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xml CFi R•PRF-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03- . _.._._ --- 04 05 06 07 Total Cavity Winter Design _ _..._,_.,Construction Name .Surface Type Construction Type Framing R -value U -value Assembly Layers Ceilings ` below- • Inside Finish: Gypsum Board yP R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @ 24 In. O.C. none 0.461 Cavity/ Frame: no insul. /2x4 inside Finish: Gypsum Board Cavily/Frame: no insul. /2x4 Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Well 2x4 @ 16 in. O.C. �..... none . . 0.302 .,.. `. , Siding/sheafhing/decking . - - -;-- Cavity/ Frame: no insul./2x4 Top Chrd Roof Deck: Wood Siding/sheafhing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 j Rooting: 10 YSF.(RoofTile),, Cavity/ Frame: no insul, /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RaolHouse Attic Attic, Roofs.; ;;;Wgod Framed Ceiling _. in. O.C. none 0.400 Roofing: 70 YSF (R _... inside Finish: Gypsum Board Ceilings (below rr0q?5` Cavity/Frame: R•9;1 /2x4 R-38 Attic 10q Radiant attic) WOtltl;F(ilrl)eti CtiiitFg 2x4 (g; 24 in o C Over Floor Joists: R-28.9 insul. _. .. 0 Inside Finish: Gypsum Board a:;di aA ,hw.4 Cavity / Frame: R -?!/2x6 Exterior Finish: Wood e,. . Sidirtg/shealhing✓decking R-21 Wall Exterior Walls Wnd:Ftamdd.11tlat('2xK @ 10'ih O•L` .,. T32I " 0066 Inside Finish: Gypsum Board Cavity/Frame: R -15/2x4 R-15 Wall House/Garage _ .. Interior Walls WoodFramed Wall ......... ... 2x4 Cu) 16 In. O.C, RIS 0.066 Other Side Finish, Gypsum Board ... ......... ._ . � � Inside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 R-21 Wall HousefGarege Interior Wells Wood Framed Wall 26 @ 16 in. O.C. R 21 0.064 Other Side Finish: Gypsum Board _._ '• -'- • Inside Finish:Gypsum Board Cavity / Frame: R-15 / 2x4 • Exterior Finish: Wood R-15 Wali Exterior Wells Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.069 Siding/sheathing/decking " Inside Finish: Gypsum Board F Cavily/Frame: R-21 /2x6 R-21 Knee Wall Interior Walls Wood Framed Wall 2x6 @ 16 In. O.C, R 21 0.064 Other Side Finish: Gypsum Boaid.. . Registration Number: 216-N0141420A-0000000040000 Registration Date/Time: 206-04-15 14:3G:49 HERS Provider: CaiCERiS Im.:: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016-04-14 16:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation DateMme: 16:39, Thu, Apr 14, 2016 Page 7 of 10 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xm1 .... SLAB FLOORS 01a X02; 2...aw --� 01 :?. 02 03 04 05 06 . Name.System 01 02 03 04 OS 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value 8 Depth Carpeted Fractlon Heated Slab -on -Grade House 3153 235 None 0.8 No Garage Slab ._Garage_ '. 618""""" 66 None 0 No BUILDING ENVELOPE- HERS VERIFICATION- r 01 .- .. ......, . 02. 03 04 ...... ... .. ...... .. ... _. Quality Insulation Installation (Qll) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFMSO Not Required Not Required Not Required" —. WATER HEATING SYSTEMS, 01a X02; 2...aw --� 01 :?. 02 03 04 05 06 . Name.System Type -" Distribution Type Wafer Heater Number of Heaters Solar Fraction DHW S 1 - 111 S pWW� x;., „,x s<<•� (HERS req'd) Recirculation. '" DHW Heater 1 1 .0% DemandControlPushButton WATERAFATERS 01a X02; 2...aw --� mw 03.E .a ' x 04Cbems' .. OS �r _F & .:06 ... 07 08 .. ... Name ..:.... ... Heater Element Type .ry Tank VaIuma Tank Type (gal) Energy Factor or Efficiency lnput.Ratingi' Tank Exterior Insulation R -value ..._. Standby Loss (Fraction) DHW Heater 1 Natural Gas i Small Instantaneous .,._ 0 . ....... 0.82 189000-Blufhr 0 0 WATER HEATING . HERS VERIFICATION 01 02 03 04 OS OB 07 -- Recirculation Central ONW' ` Name Pipe Insulation Parallel Piping `. Compact Distribution Point -of Use Control Distribution _......._, .. . .... ...... Recirculation, DHW Sys 1 - 1/1 — Demand Control Push — Button Registration Number: 216-NO14142OA-0060ODaoe-009O Registration Date/time: 201604.1514:36:49 HERS Provider: CeICERTS Inc,: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFl R-04072016.744 Report Generated at: 2016-04-1416:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation Datefrlme: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xml CF1R-PRF-01 Page 8 of 10 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 as SC Sys Name .. . ................. System. Type Meeting Unit Name Coaling Unit Name Fan Name Distribution Name Cooling Component 1:Healing Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 ... .. _. 02 _. ._. 03 Name .. ... ........ - Type Efficiency Heating Component 1 CnVlFurnace-Fualdaed i;,titaPtNzd3ce 80 AFUE HVAC - COOLING UNIT TYPES 01 1 .04 OS 06 ...... ... ,. Name Verified Airflow Airflow Target Verified EER Verified Refrigerant Verified SEER Charge, Cooling Component 1 -hers -cool Required 01 421 03 = 04 05 0607 Air Distribution System None 1 -here -dial Low4eaka e g Air Handler ' Required Efficiency _. Nol Required Not Required Multicpeed "'No1 Required Name SEER Zonally Controlled Compressor HERS Verification ...... _ Cooling.. Component 1 rCor+d 11'7 14 Not Zonal Single Speed Cooling Component C t 1 -hers -cool... 11VAgCOOLING -HERS VERIFICATION, 01 1 .04 OS 06 ...... ... ,. Name Verified Airflow Airflow Target Verified EER Verified Refrigerant Verified SEER Charge, Cooling Component 1 -hers -cool Required 350 Not Required ..., Not Required Required HVAC - DISTRIBUTION SYSTEMS Ot 02 ... ..... 01 _._ 0203 . ......:.: ... . .......04.. 05 06 07 Name Type "" Duct Leakage R-tiraluo' Duct Loeatlon Bypass Dud HERS Verification Air Distribution System 1 DuctsAltic Sealed and tested flneulation 8 Attic Air Distribution System None 1 -here -dial HVAC DISTRIBUTION - HERS VERIFICATION Ot 02 03 04 _..... OS 06 . 07 Oe ' Name - - Duct Leakage ""' Verification Duet Leakage' Targat (%) " Verified Duct Location Verified Duct Design Buried Duels Deeply Burled y Ducts Low4eaka e g Air Handler Air Distribution System 1 -hers -dist Required 6.0 _. Nol Required Not Required Not Requirid - "'No1 Required :— Registration Number: 21&NO141420A-000000000-0000 Registration Date/Time: 2016-04.1514:38:49 HERS Provider: CaiCERTS (nc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016.744 Report Generated at: 2016-D4-14 16:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation Daterrime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lennr291.xmI CFIR-PRF-01 Page 9of10 HVAC -FAN SYSTEMS 01 03 04 NaMi . .... .. Ty . pe Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Far.0.58 HVAC Fan 1 -hers -tan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 R3 Name . ... ... Verified Fan Watt'Draw Required Fan Efficiency (Watts/CFM) ......<-.. 'HVAC Fan Required 0.58 ......... . 1AQ (indoor Air Quality) FANS 01 02 03 04 05 Dwelling Unit IAQ CFM i IAQ WattsiCFMIAO ..... ........ .................. ... .... ......... Fan Type Effectiveness(Yo) . ... HERS Verification w SFam1AW6hiR( 6153 ......�0.25 Defaull 0 Required N%v 1-1 E R P IR 0 V 11 JR Registration Number: 216-NO14142DA-000000000-0000 Registration Date/Time: 2016-04-1514:36:49 HERS Provider: CaICERTS Inc, CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016.04.1416:40:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Belmont Collection - Plan #2 Reverse (Lot 148) Calculation DatefTime: 16:39, Thu, Apr 14, 2016 Calculation Description: Title 24 Analysis Input File Name: Lenn291.xml CFIR-PRF-01 Page 10 of 10 DOCUMENTATION'AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: - - Rick Maurer'-- Company: - ......:...... . -. Signature Date: ....... ...... . Rick Maurer Title 24 Inc 2016-04-15 14:36:38 ' Address """ CEA/HERS Certification Identification (If applicable):.J�.. ,7544 Saddlehili Trail - R13-90-10024 g1.1uleSr Wag City/Slate/Zip: __... Phone: ............. :Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT .. ... ........ ..... I certify the following under penalty of perjury under'lhe laws of the State of California; 1. 1 am eligible under Division 3 of the Busyness end Professions Code to accept responsibility for ate building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications Identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. b �s 3. The building design features orsystem design features Identified on•this Certificate of Complianco are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitied ta,Q19 chtorcamenl epensyiar allprova) vhS t ttlls.Elntding permit application. Res nsibie Designer Name: ; po g >. ReiftioaatWa Dablq ter•S'go lureIs James Jenike .:,. Company:„;� t�.•.,P � R ,�.. 9 Lennar Homes - Southern CA t 201 i (?4 1514,36: " 3 Address: Liwnse: - 980 Montecito Drive, Suite 302 _......_ City/StalelZlo:. ..... .. ... ...._...:. _.. ....._ i Corona, CA 92879:951-817-3500 J.Phonc: Digitally signed byCalCERTS. This digital signature is provided in order to secure the content of this registered document. and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 211"014142DA-000000080-0e00 Registration Date/Time: 2016-04-1514:36:49 HERS Provider: calCERTs inc.. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - Cf lR-04072016-744 Report Generated at: 2016-04-14 16:40:34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes. -...Plan #2 Reverse (Lot 148) Date 4/14/2016 System Name HVAC ....... Floor Area 3,153 ENGINEERING CHECKS SYSTEM LOAD Number of Systems ? COIL CFM Total Room Loads 1;96.2 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan : Supply Air Ducts2,328 TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System _......................._............................................. Out ut er S stem. 64;000 .................._......!PM..._P....:. �' ___ 0 Total Output Btuh 12800 0 Sensible . Latent CFM Sensible 40,328 4 242 840 32,662 0 ^_ 2,328 Output Btuh/s ft p ( — 40.6 1.605 Coolin .S stem o a Output per System 42,000 0 0 0 0 Tota! Output (Btuh) ............ —, 84,000. _.0 4242 w ,................... 0 1.605 Total Output Tons 7.0 .. Total Output (Btuh/s . ft) 26,6 Total Out uts. ft/Ton 450.4 � 44,984 35,872 .Air S.: tern ..... ...... ..........._. - : CFM,per System 1,600 , HVAC EQUIPMENT. SELECTION Airflow(cfm _ _ 3,200 HVAC Equipment Selection & Sizing by Others 56,406 14,825 128,000 Airflow,(cfm/sgft) 1,01 Airflow cfm/Ton) 457.1 Outside Air %) ° 0.0 /0 Total Adjusted System Output 56406 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 14,825 Aug 3 PM 128,000 F Jan 1 ANi Outside Air cfm/sqk 0.00 Note: values above given at AR! conditions HEATING SYSTEM PSYCHROMETRICS (Atrst'rearri Temp6r tures at Time of Heating: Peak): - 26 OF Outside Air! 0 cfm 68 OF 68 OF ,: 105 OF 105 OF Heating Coil Supply Fan 3,200 cfm U=—J ° 105 F ,Room. l 68 OF . 1: COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air 0 cfmCooling 76 ! 62 OF 76/62°F 55/54°F 55/54°F ........... Coil Supply Fan 56 / 54 OF 3,200 cfm 47.6% 75162 OF .. ...........: EnergyPro 6.7 by EnergySo/t User Number: 1686 RunCode:.2016-04-14T16 46-37 ID: : Page 13 of 13 SKY- LWjMT!57 3,n;� toxo = yfss�o n rn©n,--Vj Al J, -e- x tO = It- S' b- c,,rz*vl • 1 8' X', ' = 1? 1=-. (z) ®lf.�'Lrrf. J�x�'' �y�l ✓n..F'o►-r�fNSO i3A-3 tx = I� OrLrvl n4e- . ..E . U l PMENT COR eQUAL. L.A L JINTit�, .G,� Mr=GH; SP d0- +-♦EATING, AIG GiAS FURNACE. AGUE Cmlw) STV I N PUT DTU OUTPUT GFM LOW L.EAi4AGjS : Al FAIN WATT ®RAS/ COOL -044 Colt= TXv VERIFIEV A1QF'L CO NCENSE,R sEF-R/ ElFQ (MIN.). TQ NS t3TU c. Co c'150 5Et-Ac.7. e 116 do VIERI FIRED E -ER R.ic Ir;ZI G, G1-�AIZG� . WATER wwymt G,ALLO�.IS aTU H tNPVT REcovs-oY �NTcT2C�Y _�AGi�'�ft' FIRST HR, RATINCj: HOT HLO PIPE INS. T.�►aa >� L��� C7 8o C -AL_. - F SlWo a HVAC DUCT lml%% w . _ R• a.o HVAC ouGT TEST REG?'iD. N1CgNT SET'-j5AC.K T+-lEtzMOSTaT REC�VIREO. VErZ1Y Sc�VNQ oizt7�NANGE (IF AtJY� i�1Z1C�R TO A.jG SET'. �}E HVAC- EQU%F 1ENT SIZ.I1.1G1 For Energy Features that require HERS field verification, registered copies of the following checked CF3R verification and diagnostic testing certificates shall be posted or made available to the enforcement agency.. Prior to final inspection a copy of the following checked CF2R installation certificates shall be posted or made available to the enforcement agency. Verification Installation Certificate Certificate Document Category Document CF3R(HERS) CF2R Category Description Description Envelope X .. ENV -01 Non HERS Fenestration/Glazing Envelope X ENV -02 Non HERS Envelope Air Sealing Joints & Openings Envelope X ENV -03 Non HERS Insulation Installation Envelope Roofing X ENV -04 Non HERS Cool Roof - Radiant Barrier Envelope Building Envelope Air Leakage _.. ENV -20H HERS Blower Door Test . ENV- Envelope 21 H-24HHERS Quality Insulation Installation QII Lighting X LTG -01 Non HERS Single Family Lighting,.... Lighting LTG -02 Non HERS Multi -Family Lighting. Mechanical HVAC Systems & Ducts X MCH -01 Non HERS Return Air Filter Labeling Mechanical MCH -02 Non HERS Whole House Fan Mechanical Duct Leakage Test X X MCH -20H . .... .._ HERS Low Leakage Air Handler LLAH Mechanical Duct Location MCH -21 H HERS Conditioned Space Mechanical Fan Watt Draw Efficacy (FWD) X X MCH -22H HERS .58 Watts/CFM Mechanical . Cooling Coil Airflow (CCA) X X MCH -23H HERS 350..CFM/Ton ..._ _...... Building Envelope Air Leakage MCH -24H Mechanical Blower Door Test HERS w/Ducts in Conditioned Space ............. Mechanical X ..... _.....X: ,. _ _ _ : MCH -25H HERS Refri eran. t. Char a Verification Mechanical MCH -26H HERS SEER & EER Verification Mechanical Indoor Air Quality & Mechanical Ventilation X X MCH -27H HERS ASHRAE 62.2 Continuous Fan Mechanical Return Duct & Filter Grille Sizing MCH -28H HERS . ....... Alternate to FWD & CCA Mechanical Supply Duct Surface Area, MCH -29H HERS R -Value & Buried Ducts Plumbing PLB-01 Non HERS ................ ..... ..PLB-21 H HERS Multi -Family Hot Water Distribution System Plumbing X PLB-02 Non HERS X PLP -22H HERS Single Family Hot Water Distribution System SUPERINTENDENTS Please coordinate with you subcontractors and HERS rater the importance of having the above checked certificates filled out on time to prevent any hold-ups during final inspection. Keep in mind that some of these items need to be inspected by the HERS rater prior to drywall. Continuous Ventilation Calculation Each whole building ventilation system must meet the minimum CFM required and field verified with diagnostic testing of airflow performance. In addition, the fan must be certified with a maximum sone rating of 1.0 or less. CFA =100 + 7.5 W of Bedrooms +1) = Ventilation Rate (Min. CFM @.25" W.C.) . Plan 2 Reverse Lot 148 3153 _ 100 + 7.5 (3 + 1) = 31.53 + 30.0 = 61.53 Min. CFM 1 n LEGEND 4884 KE tf. W Z CAR WAS( i .. a _... w- NOTE: DIMENSIONS SHOWN ARE NOTE: PIAT PLANS MAY NOT SHOW CURRENT RECORD INFORMATION. REFER TO THE., TO BUILDING FACE AND NOT TITLE REPORT FOR DIMENSIONS, EASEMENTS, AND OTHER INFORMATION OF RECORD. " ARCHITECTURAL POP -OUTS DRY UTILITIES ARE NOT SHOWN ON THIS PLAN: MSA CONSULTING, INC LENNAR / GRIFFIN RANCH pmom a Crm Emnammm m DLaic Smvum APRIL 2016 34200 eoe Hom Dam • RAm= > . CA =� TRACT NO. 32879 C760' °'� ' PA" (760' 323-7M LOT 148 - 54-930 Madagascar Way ;OTA s LENNAR LA =NTA, RNUSDE COUNTY, CALIFORNIA . 980 MONTECITO DRIVE [7 - CORONA, CA 92879SCALE 1'=30' (951) 817-3663" — PROPERTY LINE ® AIR CONDITIONING PAD — -- — -- --- — — PUBLIC UTILITY EASEMENT 0 CONCRETE STOOP — — — — — — RIGHT—OF—WAY (R/W) R SIDEYARD GATE H,_.._ ._,__::_ WATER MAIN FIRE HYDRANT — — --- —5 — SEWER MAIN ® WATER METER GARDEN WALL S SEWER LATERAL RETAINING / GARDEN WALL TOP OF SLOPE TOE OF SLOPE 4884 KE tf. W Z CAR WAS( i .. a _... w- NOTE: DIMENSIONS SHOWN ARE NOTE: PIAT PLANS MAY NOT SHOW CURRENT RECORD INFORMATION. REFER TO THE., TO BUILDING FACE AND NOT TITLE REPORT FOR DIMENSIONS, EASEMENTS, AND OTHER INFORMATION OF RECORD. " ARCHITECTURAL POP -OUTS DRY UTILITIES ARE NOT SHOWN ON THIS PLAN: MSA CONSULTING, INC LENNAR / GRIFFIN RANCH pmom a Crm Emnammm m DLaic Smvum APRIL 2016 34200 eoe Hom Dam • RAm= > . CA =� TRACT NO. 32879 C760' °'� ' PA" (760' 323-7M LOT 148 - 54-930 Madagascar Way ;OTA s LENNAR LA =NTA, RNUSDE COUNTY, CALIFORNIA . 980 MONTECITO DRIVE [7 - CORONA, CA 92879SCALE 1'=30' (951) 817-3663" —