09-0777 (RC) Title 24I TITLE '24 REPORT I Title 24 Report for: Addition to the Raquet Club Building 3s5' Lu Mn s, Project Designer: Curtis R. Shupq, Architect 72-880Fred Waring Drive, Suite A-5 Palm Desert, CA 92260 760-346-7354 Report Prepared By: MRC Engineering MRC Engineering, Inc. 72-880 Fred Waring Drive Suite C-11 Palm Desert, CA 92260 _ (760) 340-9005 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DArE q W11 o BY ob Number: _7-17 9045.00 Date: 7/16/2009 The EnergyPro computer program has been used to perform the calculations summate In this compliance report This program has approval and is authorized by the California Energy Commission for:use with both the Residential and: Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoftcom. EnergyPro 4.4 by EnergySoft Job Number. 9045.00 User Number. 7746 JUL 1 7 200.9 Py. Title 24 Report for: Addition to the Raquet Club Building 3s5' Lu Mn s, Project Designer: Curtis R. Shupq, Architect 72-880Fred Waring Drive, Suite A-5 Palm Desert, CA 92260 760-346-7354 Report Prepared By: MRC Engineering MRC Engineering, Inc. 72-880 Fred Waring Drive Suite C-11 Palm Desert, CA 92260 _ (760) 340-9005 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DArE q W11 o BY ob Number: _7-17 9045.00 Date: 7/16/2009 The EnergyPro computer program has been used to perform the calculations summate In this compliance report This program has approval and is authorized by the California Energy Commission for:use with both the Residential and: Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoftcom. EnergyPro 4.4 by EnergySoft Job Number. 9045.00 User Number. 7746 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form ENV -1-C Certificate of Compliance 3 Form ENV -3-C Overall Envelope Method 5 Form ENV -MM Envelope Mandatory Measures 12 Form MECH-1-C Certificate of Compliance 13 Form MECH-2-C Air & Water System Requirements 15 Form MECH-4-C HVAC Misc. Prescriptive Requirements 16 Form MECH-MM Mechanical Mandatory Measures 18 EnergyPro 4.4 by EnergySoft Job Number. 9045.00 User Number. 7748 [CERTIFICATE OF COMPLIANCE (Part 1 of 2) ENV -1-C PROJECT NAME DATE. Addition. to the Ra uet Club Building 7/16/2009 PROJECT ADDRESS 79295 Rancho LaQuinta Di ine LaQuintsmg ; PRINCIPAL DESIGNER - ENVELOPE 'TELEPHONE . rl udap,.ermit':# g A� 0 _ . Curtis R. Shupe, Architect 760-346-7354 DOCUMENTATION AUTHOR TELEPHONE edrby/pate"" T MRC Engineern , Inc. 760 340-9005 e;i, GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 7-16-09 997 Sq:Ft. 15 BUILDING TYPE NONRESIDENTIALHIGH' RISE RESIDENTIAL HOTELIMOTEL GUEST ROOM ❑ ,RELOCATABLE- Indicate:❑ Specific Climate -dist: , or Ail Climates PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION FXI ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit) METHOD OF'ENVELOPE ❑ COMPONENT(EN.V-4;C) X OVERALL ENVELOPE(ENWI-C) ❑ PERFORMANCE COMPLIANCE STATEMENT OF'COMPLIANCE This Certificate of Compliance lists -the building features and' performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the document is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE MRC En ineerin The Principal Envelope Designer'hereby certifies that the proposed building design represented in this set of construction documents,is.consistentwiththe other compliance formsand worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in Sections 110, 116 through 1181 and 140; 142, 143 or 149 of Title 24, Part 6. Please check one: ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and' that I am licensed in the state of California as a civil engineer or mechanical engineer, or I am a. licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3-of'the Business and'Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ 1. affirm that I am eligible. under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as: exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. PRINCIPAL ENVELOPE DESIGNER- NAME SIGNATURE DATE LIC. 0 Curtis R. Shue Architect ENVELOPE MANDATORY MEASURES Indicate location on plansaof Note Block for Mandatory, Measures ENVELOPE COMPLIANCE FORMS & WORKSHEETS Ghedc.box If worksheet.is;induded For detailed instruclions on the:use of this and all Energy Efficlency.S.tandards:compliance forms, please, refer to the Nonresidential Manual published the Califomia. EnergycCommission. ZENVA-C: Certificate of Compliance., Required on, plans forrall submittals. Part 2 may be.incorporated in schedules on plans. OENV-,2-C: UsedEnvelope Component compliance method ZENV-3-C: Used with Overall Envelope Compliance method ❑ENV -4-C:, Optional. Use for minimum skylight requirements for large enclosed spaces. EnergyP'm 4.4 by EnergySoft 'User Number 7746 Job Number. 9045:00 Page:3 of 19. . CERTIFICATE OF COMPLIANCE (Part2 of 2) ENV -1-C PROJECT NAME DATE Addition to the Raquet Club Buildinq 7/16/2009 110 Surface Type Area I U -Fac: Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location i Comments 1 Roof 431 0.051 R-19 R-0. 00 20 Loewen DbI/Wd Mtldad Low -E ADDITION EAST ADDITION S 2 Wall 44 0:074 R-19 R-0.0 0 90 New 09-A5 ADDITION EAST 3 Wall -261, 0.074,-1 New R-0 0 180 90 IWIndow 09-A5 ADDITION EAST 4 Wall 2 0.074, R-19 R-0.0 90. 90 Now 09-A5 ADDITION EAST 5 Wall 4 0.074 R-19 R-0:0 0 90 New 09-M ADDITION WEST 6 Wall 34 0.074 ,R-19 R-0:0 180 90 New 09-A5 ADDITION WEST 7 Wall 32 0.0741 RA9 R-0.0 270 90 New 09-A5 ADDITION WEST 8 Roof 562 0.051 RA9 R-0.0 270 20 New 02-A5 ADDITION WEST MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES R FI�1 More than or equal to 10,000 sqA of elle" k fenestration area must Include a label certificate eyher.issued by,NFRC; or provide a CEC Default Label Certificate using the default Wactors from I I !`.M.d..4. Tahle l IA -A -I R r tie�sfs ehnll Aa OU f N.n nl.nww �e n.wie w �nwn A,w,- -M- -w- s e . - # Tvpe Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing, Too Location/ Comments 1 Window Front N 46 0.340 NFRC 0.28 NFRC 0 New Loewen DbI/Wd Mtldad Low -E ADDITION EAST 2 Window Rear S 64 0.340 NFRC, 0.28 NFRC 180 New Loewen DbI1Wd Mtldad Low -E ADDITION EAST 3 Window Left E 330 0.340 NFRC i 0.28 NFRC 90 New Loewen DbINVd Mtldad Low -E ADDITION EAST 4 IWIndow Front N 4 .0.340 NFRC 0.28 NFRC 01 New Loewen DbVWd Mtldad Low -E ADDITION WEST' 5 Window Rear S 64 0.340 NFRC 0.28 NFRC 180 New Loewen DbINVd Mtldad Low -E ADDITION WEST 6 Window. Right W 450 0.340 NFRC 0.28 NFRC 270 New Loewen DbUWd Mtldad Low -E ADDITION WEST 1010 0.1 4.0 0 0.0 0.0 0 6 Roll -down Blind or Slats 0.13 8.0 56.0 4.0 0.1 4.0 4.0 0.1 4D 0 0:0 0.0 0 1 uiactor Type: -116-A Default Table from Standards, Table NF1 Default Table from the ACM Manuel Appendbt NFRC Labeled value. 2 SHGC Type: 118.8 DefaultTable from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt, Wd. Overhang L n. Hgt. LExt.RExt. Left Fin Dist. Len. H t. Right. Dist. Fin Lan. H t 1 Roll -down Blind or Slats 0.13 8.0 6.0 4.0 0.1 4.0 4.0 0.1 4.0 0 0:0 0.0 0 2 Roll -down Blind or Slats 0.13 8.0, 9.0 10.0 0.1 10.0 10.0 0.1 4.0 0 0.0 0.0 0 3 Roll -down Blind or Slats 0.13 8.0' 24.0 4.0 :0.1 4.0 4.0 0.1 4:0 0 0.0 0.0 0 4 Roll -down Blind or Slats 0.13 8.0 6.0 4.0 0.1 4.0 4.0 0.1 4.0 0 0.0 0.0 0 5 Roll -down Blind or Slats 0.13 8.0 8.0 10.0 0.1 10:0 1010 0.1 4.0 0 0.0 0.0 0 6 Roll -down Blind or Slats 0.13 8.0 56.0 4.0 0.1 4.0 4.0 0.1 4D 0 0:0 0.0 0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES U The proposed bu6dtrlg b in climate zones 2 through 15 and contain an enclosed Space with floor area greater Clan 25,000 ft2, a coiling height greater than 15 feet, and an LPD for general OgAtng of at Mast 0.6 WHt2. See Sector 1143(c}It this box is checked, EW44 must be filled auL when sutunKdng under the Proscrlptlw Cmnpllance Approach. EnergyPro 4.4 by EnergySoft User Number: 7746 Job Number. 9045.00 Page:4 of 19 1 OVERALL ENVELOPE METHOD (Part 1 of 7) ENV -3 - IC WINDOW AREA CALCULATION A. DISPLAY PERIMETER 135 ft x o;ff = 810 ft DISPLAY AREA B. GROSS EXTERIOR WALL AREA 1,206 fe X 0.40 = 482 R:40% GROSS WALL AREA C. ENTER' LARGER OF A OR B 1,206 810fe MAXIMUM STND. AREA D. ENTER PROPOSED WINDOW AREA 1,0021 ftp PROPOSED AREA E. WINDOW WALL RATIO = Proposed Window Area Divided by Gross Exterior Wall Area = 83.0.8% F. WEST DISPLAY PERIMETER 54 ft x 6 ft = 3241 ie WEST DISPLAY AREA G. WEST EMRIOR WALL AREA 482 Ric 0:40 = 193 fe 40% WEST WALL AREA H. ENTER THE LARGER OF F'AND G 482 324 Ile MAX. STND. WEST AREA 1. ENTER PROPOSED WEST WINDOW AREA 4501 fe PROPOSEDWEST AREA J. WESTWINDOW WALL RATIO = Proposed West Window. Area Divided by West Exterior Wall Area = . 93.367 Combined Values for North, East and South Walls K. WEIS DISPLAY PERIMETER (A - F) 81 ft x 6 ft = 4$6 fe WEIS; DISPLAY AREA L. NIEIS'EXTERIOR WALL AREA (B - G) 724 ft'x 0.40 = 290 ft, 40% WEIS AREA M. ENTER LARGER OF K OR L 724 2901 fe MAX. STAND. WEIS AREA N. PROPOSED N/FJS WINDOW AREA (D -1) 552 fe PROPOSED NOS AREA I&qNDOW ADJUSTMENT O. IF D >-C andfor if.l > H, PROCEED TO CALCULATION STEPS 1 OR 2, AS APPROPRIATE, FOR THE WINDOW AREA.ADJUSTMENT..IF NOT, GO TO THE SKYLIGHT AREA TEST, ENV -3-C, PART 2 OF 7. 1. IF I < H: Use the calculated Window adjustment forall walls. MAXIMUM.STANDARD PROPOSED WINDOW WINDOW AREA. from C AREA from D ADJUSTMENT FACTOR 2..IF I a H: Calculate one window adjustment factor (WAF) for the West well. a. Calculate;the WAF for the West wall. MAX.: STANDARD WEST PROPOSED WEST WEST WINDOW AREAfro AREA from I ADJUSTMENT FACTOR 7732741 s 145011 0.720 b. If N > M: Calculate.the WAF for the North, East and South walls. MAX. STANDARD WETS PROPOSED WEIS NIEJS WINDOW AREA from M AREA from N ADJUSTMENT FACTOR 290 _F 552 =1 0.525 GO TO PART 7 TO CALCULATE ADJUSTED AREAS. EnergyPro 4:4 by ErwgySaft User Number. 7746 Job Number. 9045.00 Page:5 of 19 OVERALL ENVELOPE METHOD (Part 2 of 7) ENV -3-C PROJECT NAME DATE Addition to the Ra uet Club Buildin 7/16/2009 A. ATRIUM HEIGHT 10 ft GROSS STANDARD ALLOWED ROOF AREA SKYLIGHT AREA B. IF <= 55 FT 99T fex 0.05 - 501 ft C. IF:,- 55 FT fex 0:10 - ft: D. PROPOSED SKYLIGHT AREA Q it° IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PART 3 OF 7. 1. IF PROPOSED SKYUGHT AREA:,—STANDARD SKYLIGHT AREA:. PROPOSED SKYLIGHT AREA SKYLIGHT STANDARMSKYLIGHT AREA (IF E = 0 ENTER 1) ADJUSTMENT FACTOR GO TO PART 7 TO CALCULATE ADJUSTED AREAS. EnergyPro 4.4 by EnergySoft User Number. 7746 Job NumberM45.00 Page:B of 10 OVERALL ENVELOPE METHOD (Part 3 of 7) ENV -3-C PROJECT NAME Addition to tl OVERALL HEAT LOSS A .ASSEMBLY NAME (e.g. Wall -1, Floor -1) Roof North Wall Window South Wall Window East Wall Window North Wail Window South Wall Window West Wall Window I Roof B C D I I E PROPOSED STANDARD AREA HEAT CAP. U- FACT: ACM JA IV Ref. UA (B X D) 435 0.051 0.05102-A5 50 22.2 44 40 0.074109-M 19.0 3.3 46 3.4 0.340 0.470 15.6 26 0:102 0.074 09-A5 1.9 64 48 0.340 4.9 21.8 25 19.9 0:074 09-A5 1.9 330 0.470 0.340 158 112.2 42 324 0.074 09-A5 3.1 48 0.3401 16.3 35 0.074 09-A5 2.6 64 0.340 21.8 32 0.074,09-A5 2.4 450 0.340 153.0 562 0.06102-A5 28.7 DATE F G H STANDARD AREA' (Adjusted) U- FACT. UA (F'X G) 435 0.051 22.2 50 0.102 5.0 40 0.470 19.0 34 0:102 3.4 561 0.470 26.5 64 0:102 6.6 291 0.470 136.6 48 0:102 4.9 421 0.470 19.9 43 0:102 4.4 56 0.470 26.5 158 0.102 16. 324 0.470 152.3 562 0.051128.7 1) In climate zones 1' and 16 the Insulating R -value of continuous; *if Window and/orSkoight'Area Adjustment Is 407 This Page Total 472 Insulation materials Installed above•theiroof waterproof Required, useAdjusted Areas from,Part 7 of 7. g membrane shall be multiplied times 0.8,befoie choosing the table column for determining assebmly U -factor. See Faohrotes, 407 Building Total 472 Tables N.1 through IV.71n the Joint Appendices. EnergyPro 4.4 by EnergySoft User Number. 7746 Job Number. 9045:00 Page:7 of 19 1 OVERALL ENVELOPE METHOD (Part 4 of 7) ENV -3-C] ECT NAME to h ue i L DATEA,dd*tion 612009RALL HEAT GAIN FROM CONDUCTION A B C I D I E F G H I I J ASSEMBLY NAME (e.g. Wall -1, Floor -1) PROPOSED STANDARD AREA TF HEAT CAP. U. FACT. ACM JJL IV Ref. HEAT GAIN (BxCxE) AREA' (Adjusted)' U- FACT. TF HEAT GAIN (GxHxl) Roof 435 55 0.05 02-A5 1,220 435 0.051 55 1,220 North Wall 44 55 0.074 09-A5 179 50 0.102, 55 278 Window 46 55 0.340 860 40 0.470 55 1,047 South Wall 26 55 0.074 09-A5 106 34 0.102 55 189 Window 64 55 0.340 1,197 56 0.470 55 1,457 East Wall 25 55 0.074 09-A5 102 64 0.102 55 362 Window 330 55 0340 6,171 291 0.470 55 7,511 North Will 42 55 0.074 09-A5 171 48 0.102 55 268 Window 48 55 0.340 898 42 0.470 55 1,092 South Wall 35 55 0.074 09-A5 142 43 0.102 55 239 Window 64 55 0.340 1,197 56 0.470 55 1,457 West Wall 32 55 0.074 09-A5 130 158 0.102 55 886 Window 450 55 0.340 8,415 324 0.470 55 8,375 Roof 562 55 0.05 02-A5 1,576 562 0.051 55 1,576 1.) In climate zones 1 and 16 the insulating R -value of continuous Insulation materials installed above the roof waterproof membrane shell be muttlplied times 0.8 beforechoosingthe table column for determining assembly U -factor. See. footnotes, Tables N:1 hroe h IV in the JointAppendices. I 'If Window and/or Skylight Aiea Adjustment Is Required, use Adjusted Areas from Part'6 of 7. -22,3641i,25 957 Subtotal Subtotal EnergyPro 4.4 by EnergySoR User Number. 7746 Job Number: 9045.00 Pagw a of 19 NAME Addition to the Raouet Club Build (Part 5 of 7) ENV -3 -Cl DATE ROOF ABSORPTANCE CALCULATION R-21 Roof Cathedral CHECK APPLICABLE BOXES Case 1 - Proposed YES NO A 1. CRRC-1 Certified? 2. Is the thermal emittance > 0.75? 3. Enter the' Initial reflectance ph* value: 4. Calculate a. = 0.94 - 0:7p=p B C I D E F G Go to 2. Go to 3. X Go to 8. Go to 5. Go to 4. Insert value in calculation. Enter calculated value In Column F below. STANDARD ASSEMBLY NAME (e.g. Roof -1) p w. ora = a" = WF Case 2 - CRRC-1 Tested Absorp HEAT GAIN [(BxCxDxExF) S. Enter Initial reflectance & emitfance values from CRRC-1 ,6. Calculate pwPw to . 0.448 + 1.121 pto+ 0.524 EM 7. Calculate a = 0.94 - 0.7 p m. P U -Factor EM = Go to 6. Insert values in calculation. Go to 7. Insert,value inzalculation. Enter calculated value In Column F below. PM = p RLP" = a p" = 435 8. Not:CRRC-1 Tested 0.92 0. 51 For nonresidential low -sloped roofs: For all other roofs: [Rpm 00.87 Enter default value In Column F below. 8. = 0.73 Enter default value In Column F below. Standard absorptance values for Column J are either 0,0510.73 For nonresidential low -sloped roofs: For all other roofs: ' a m = 0.45 Enter standard value In Column J below. am 0.73 Enter standard value in Column J below. LQV_ERALL HEAT GAIN FROM RADIATIOR OPAQUE SURFACES A R B C I D E F G H I J K PROPOSED STANDARD ASSEMBLY NAME (e.g. Roof -1) AREA SF WF U- FACTOR Absorp HEAT GAIN [(BxCxDxExF) AREA" (ADJUSTED). U -Factor Absorp HEAT GAIN (CxDxHxfxJ) Roof 435 123 0.92 0. 51 1,833 435 0,0510.73 1.833 Roof 562 0.92 nnsi 22811 sR2 n-nsi n VA ,ARA 4 2 Subtotals are entered under-SubtOtar 4 200 SUBTOTAL In COLUMNS bend M of ENV4-C, Part SUBTOTAL 0 Of 7., EnergyPro 4.4 by EnergySoft User Number. 7746 Job Number. 9045.00 Pa .9 of 19 OVERALL ENVELOPE METHOD (Part 6 of 7) ENV -3-C PROJECT NAME DATE Addition to the Raauet Club Building 7/16/2009 IOVERALL HEAT GAIN FROM RADIATIONFENESTRATION SURFACES 22,364 A 0 C D 1 E I F G I H I J K L M ININDOWISKYUGHT NAME e.g. Wind -1, Sky -1) ORIENT. WEIGHTING FACTOR PROPOSED STANDARD AREA SF t SHGC OVERHANG 4,200 HEAT GAIW BxC:DxExH) AREA (ADJU8TED RSHG a or SHGC SF HEAT GAIN BxJxKxL) H V HN OHF Window N 0.61 46 123 0.28 4.0 8.1 0.49 0.85 818 40 0.40 123 1.215 Window S 1.27 64 123 Total Had Galin 62 924 EnergyPro 4.4 by EnergySoft User Number. 7746 Job: Number: 9045.00 1,232 56 0.31 123 2,729 Window E 1.07 330 123 0.28 4.0 8.1 0.49 0.63 7,674 291 1 123 11.854 Window N 0.61 48 123 42 0.40 123 1.268 WIndow S 1.27 64 123 0.2810.0 8.1 1.23 0.44 1,232 56 0.31 123 2,729 Window W 1.05 45C 123 324 0.31 1231 12972 1. From Fenestration Surfaces ENV -1-C, Part 2, .Column:G, or when'Column Part 4 Subtotal 22,364 Part 4 Subtotal 25,957 H has a'C- Identifier, calculate using the center of glass value SHGCc in. SHGCfen - .06 + (0.86xSHGCc) and enter value. 4.200 4,200 4. Proposed Heat Gain, Column I may be no greater than Standard Heat Part 5 Subtotal Part 5 Subtotal Gain Column M. 3 .If Window and/or Skylight Area Adjustment is required, use adjusted area Part 6 Subtotal 22.077 Part 6, Sul- ubfrom fromPart 6 of 7. 4. Only SHGCls used for.Skylights 48 64 Total Had Galin 62 924 EnergyPro 4.4 by EnergySoft User Number. 7746 Job: Number: 9045.00 Page:10 of 19 OVERALL ENVELOPE METHOD Part 7 of 7 ENV -3-C NAME ub Buildi 7/16/2009 WINDOW AREA - ADJUSTMENT CALCULATIONS ❑ CHECK IF NOT APPLICABLE'(See Part 1 of 7) ORIENTATION E F G WINDOW ADJUST. FACTOR (From Part 1) ADJUSTED WINDOW AREA (D X E) ADJUSTED WALL AREA B - (F + C) A 8 C D WALL NAME (e.g. Wall -1, Wall -2) GROSS AREA DOOR AREA WINDOW AREA N E S W X] ❑ ❑ ❑ ❑ ❑ IX ❑ ❑ 0 ❑ ❑ X] 1:1 ❑ ❑ 1:11:1 X❑ ❑ ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ TOTALS North Wall 90 0 46 0.880 401 50 South Wan 9.0 0 64 0.880 56 3 East wall 355 0 330 0.880 291 6 North Wall 90 0 48 0.880 42 48 South Wall 99 0 64 0.880 56 4 West Wall 482 0 450 0.720 324 158 EwWPm 4.4 by EmxgySoft User Number .7746 Job Number. 9045.00 Pagel 1 of 19 1,2061 01 1,00 N/A 8101 39 ISKYLIGHT AREA ADJUSTMENT CALCUUIIONS FXICHECK IF NOT APPLICABLE (See Part 2 of 7) D E F SKYLIGHT ADJUST. FACTOR (From Part 1) ADJUSTED SKYLIGHT AREA (C X D) ADJUSTED ROOF AREA (B - E) A B C ROOF NAME (e.g. Roof -1,, Roof -2) GROSS AREA SKYLIGHT AREA TOTALS N/A EwWPm 4.4 by EmxgySoft User Number .7746 Job Number. 9045.00 Pagel 1 of 19 ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE Addition to the Raquet Club Building I 7/16/2009 DESCRIPTION Designer Enforcement 0 6118(a) Installed insulating Material shall have been certified by the manufacturer to comply.with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 8. D 6118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 70T of Title 24, Part 2. M§ 117(a) All Exterior Joints and openings in the building that are observable sources of air leakageshall be caulked, Basketed, wentherstripped or otherwise sealed. X❑ §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows Installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products -must be labeled for U -value according to NFRC procedures. §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed.demising walls in nonresidential buildings shall have Insulation with an installed R -value of no less than R-18 between framing members. EnergyPro 4.4 by EnergySoft UserNumber'7746 Job. Number. 9045.00 Page:12 of 19 CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-1-C PROJECT NAME DATE OF PLANS DATE Addition to the Ra uet Club Building 7-16-09 7/16/2009 PROJECT ADDRESS BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ®ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit) 79295 Rancho LaQuinta Ddne. LaQuints COMPLIANCE Building'Permit # PRINCIPAL DESIGNER - MECHANICAL TELEPHONE Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. MRC Engineeing Inc. 760-340-9.005 - - -� DOCUMENTATION AUTHOR TELEPHONE Checked by/Date MRC Engineering, lnc. (760) 340-9005 sEdIbmernent,Agency QIENEIRAIL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 7-16-09 997 sq.Ft: 1 15 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ®ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit) METHOD OF MECHANICAL PRESCRIPTIVE ❑ PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications: needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documenta ' n'is aocurat complet DOCUMENTATION AUTHOR SIGN JDATE G- The Principal Mechanical Designer hereby certifies that the pro d building design represented in this set of construction documents is consistent Wth the other compliance forms and sheets, with the specifications,. and with any other calculations submitted with this permit application. The propos building has been designed to meet the mechanical requirements contained in the applicable parts of Sections 100, 01, 102, 110 throughl 15, 120 through 125, 142, 144, and 145. ❑ The plans & specifications most the requirements of Part 1 (Sections 10-103x). ❑ The installation certificates meet the requirements of Part 1. (10-103a 3). ❑ The operation & maintenance Information meets the requirements of Part1 (10-103c). Please check One: (These sectionsof the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and,that I;am licensed in the. State of California as a civil engineer, or mechanical engineer or I am a licensed architect. 1 affirm that I am eligible under the exemption to Division 3 of the Business and. Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; -and that I am a.licensed contractor performing this work.. ❑' I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code'to sign this document because it pertalnsto a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER.- NAME L,11 DATE LIC. # tit 7RE I MRC Enaineerinti Inc, AVX. b2.fM-.3 45Sr INSTRUCTIONS C T ® MECH-1-C: Certificate of Compliance. Part 1, 2, 3 of 3 are required on 'plans for all submittals. IN MECH-2-C: AirMater/Service/Water Pools. Requirements. Part 1 of 3,2 of 3, 3 of 3 are required for all submittals, but.may be on plans. 0 MECH-3-C: Mechanical Ventilation and, Reheat is required for all: submittals with mechanical ventilation, but maybe on plans. LN MECH-4-C: HVAC Misc. Prescriptive Requirements is required for all prescriptive submittals, but may be on plans. ❑ MECH-5-C: Mechanical Equipment Detalls are required for all performance submittals. EnergyPro 4.4 by EnergySoft User Number. 7746 Job Number. 9045.00, Page:13 of 19 CERTIFICATE OF COMPLIANCE (Part 2 of 2) MECH-1-C NAME DATE 6/2009 uesigner: This form Is to be used by the designer and attached to the plans. Usted below are,all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that.requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM, Manual that describes the test. Also Indicate the,person responsible1or performing the tests (i.e. the Installing contractor, design professional or an agent. selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope, of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed, building or space, ora new space -conditioning, system serving a building or spaow Is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted,to the building department that certifies plans, spedticatlons, Installation certificates, and operatina and maintenance. Information meet the requirements of Section 10-103(b) and Title 24 Part 6. T TE ENT OF COLAPLIANCE D MECH-2-A: Ventilation System Acceptance Document. Variable Air Volume. Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing TestnWked on all New syslams both New Construction and Reboft D'MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test requhed on all New systems both New Construction and Reboot ❑ MECH-4A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test requked on all Now systems both New Consbucdon and Retrofit Unita.mM economizers that are Installed at" factory and owfifled with the commission do not require equipment Gesifng but do require construction Inspection. D MECH-S-A: Air DistributionAcOaPtanceL Document Equipment requiring acceptance testing This test requked IF Me unit serves 5,000 V ofspace orfess and 25 6 amore or pre ducts araln noncondNioned or samicondrb oned space like an attic New systems Met meet Ma above requkemerft Retrofit systems that meet the aboverawksments and elitw extend duds, replace ducts or replace Me packaged urdt D MECH4)-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on crew or existing packaged systems must be tested: D MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fen volume controls installad on new or existing systems must be lasted. D MECH-6-A:-Hydronic System Control Acceptence;Document -Variable Flow Controls Applies toduredand hot water systems. Automatic Isolation Controls Applies to now balers and dialers and Me priniary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chlied and hot water systems Mat hove a design cspadty greater than or equal tc 500,000 Bbuhr. -Water400p Heat Pump Controls Applies to all new watadoop heat pump systems where the comWned1oop pumps are psefor Men, 5 hp. -Variable Frequency Controls Applies ban new dlaftution pumps on new variable flowWled, hy&MIC heat pump. or condenser wafer systems where Me pumps motors we pealer 9ren 5 hp. Equipment uirin acceptance testing EnergyPro 4.4 by EnergySoft_ User Number. 7746 Job Number. 9045.00 Page:14 of 19 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C Addition to the Raouet Club Buildina 1 7/16/2009 1 ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efflclency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.432 Proposed Heating:Capactty 2 Calculated Sensible Cooling Capacity x 1.212 ProposedSensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressurs Reset (DDC only). ,Simultaneous Headcool Economizer Heating Air Supply Reset Cooling .Air Supply Reset Duct Sealing for Prescriptive Compllanceg AIR SYSTEMS Central' orSin le Zone ADDITION EAST ADDITION WEST 1 1 T-24 Section Reference on Plans or Specification 112(a) 7.70 HSPF 7:70 HSPF 112(a) 16.0 SEER / 13.0 EER .180 SEER / 13.0 EER 112(b) Yes Yes 112(c), 115(a), n/a n/a 121(b) Yes Yes 121(b) 0 cfin 0 cfm 121(c) No No 121(c) No No 121(c), 122(e) Prourammable.Switch Proarammable Switch 122(e) Heating & Cooling Required Heating &Cooling Required 122 Auto Auto 122 n/a n/a 123 124 n/a n%a 144. a & b 13,563 btuh 17,280 btuh 1441a & b 35,039 btuh 35,039 btuh 1441a & b 13,507 btuh 19,232 btuh 144 a & b 28,950 btuh 29,464 btuh 144 c Constant Volume Constant Volume 144 c 144 c Yes Yes 144 (d), No No 144 a No Economizer No Economizer 1.44 Constant Ternp Constant Tem 144 (f) Constant Temp Constant Temp 144 k No No. 1: For each central and single none air systems (or group of similar units) fill In the reference to sheet numberandlor specification section and paregraph number where the required features are documented. If a requirement Is notapplicabie, put "NW In the column. 2: Not required for hydronlc heating and cooling. Either enter, a value here or put In reference of plans and'spedficatons per footnote 1. 3: Enter Yes If System U: Constant Volume, Single zone; Serves <. sgft; Has > 25% duct in unconditioned space: Duct sealing is required4br Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. IMECHANICAL SIZING AND FAN POWER MECH-4-C PROJECT NAME DATE Addition to the Ra uet Club Building 7/1.6/2009 SYSTEM NAME ADDITION EAST FLOOR AREA 435 FFA—N;*75ON FAN DESCRIPTION Supply Fan B DESIGN BRAKE HP 0.062 C 0 E F EFFICIENCY 120 NUMBER OF FANS PEAK WATTS B x E x 7461(C X D) OT DRIVE 40.2% 97.0% 1.0 120 6 Fan Adjustment =1 SPa,- iySPf 144(i) ADJUSTED FAN POWER INDEX Line 3 x Line 6 0.120 11. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/ch for Constant Volume systems or 1.25W/cfin for VAV systems. ITEM or SYSTEM TAG(S) Total Adjustments FILTER PRESSURE ADJUSTMENT EQUATION A) If filter pressure drop is greater than 1 inch W.C. enter filter pressure drop. SPa on line 4 and Total Fan pressure SK on Line 5. B) Calculate Fan Adjustment and enteron Line 6. C) Calculate Adjusted, Fan Power Index and enter on Line 7. 1 TOTAL.FAN SYSTEM POWER(Watts, _Sum Column 120 2 SUPPLY DESIGN AIRFLOW CFM 1.,000 3 TOTAL. FAN SYSTEM POWER INDEX.(Row 1/Row 21 41 SPa 144 h 5 Ism 6 Fan Adjustment =1 SPa,- iySPf 144(i) ADJUSTED FAN POWER INDEX Line 3 x Line 6 0.120 11. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/ch for Constant Volume systems or 1.25W/cfin for VAV systems. ITEM or SYSTEM TAG(S) PRESCRIPTIVE MEASURES Electric Resistance Heating 1 Heat Rejection System 2 Air Cooled Chiller Limitation 3 T-24 Section Capacity Exception Notes 144 144 h 144(i) 1. Total installed capacity, (MBbrlhr) of all electric heat on this project exclusive of electric auxillary heat for heat pumps. M.electric heat Is used, explain which exception(s) to Sectlon(g) apply. 2. Are centrifugal fan cooling towers used onlhis pro)ect? (Enter 'Yes" or 'Ne) R centrifugal fan cooling tower are used, explain which exception(s) to Section 144(h) apply. 3. Total installed capacity (tons)'of all,vrater and air cooled chillers under this,pennll. If there are more than 100 tons of air-cooled chiller rapacity being Installed, explain which exception(s) to Section 144(i) apply. EnefgWro 4.4 by EnergySoft User Number,. 7746 Job Number. 9045.00 Page:16 of'19 MECHANICAL SIZING AND FAN POWER MECH-4C PROJECT NAME DATE Addition to the Ra uet Club Building 7/16/2009 SYSTEM NAME ADDITION WEST FLOOR AREA 562 FAN POWER CONSUMPTION FAN DESCRIPTION SUPPIY Fan B DESIGN BRAKE HP 0.062 C I D Total Adjustments F EFFICIENCY 12O NUMBER FANS PEAK WATTS Bx E x 748 / (C X D) MOTOR DRIVEOF 40.2% 97.0% 1.0 120 g Fan AcQusbnent =1 SPa -1 SPf 144(l) 7 ADJUSTED FAN POWER'INDEX Line 3 x Line 81 0.120 I. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER, INDEX must not exceed 0:8 W/ctrn for Constant Volume systems. or 1:25 W/ahn for VAV systw, ITEM or SYSTEM TAG(S) Total Adjustments FIR.PRESSURE ADJUSTMENT EQUATION A) If filter pressure drop is greater than 1 inch W.C. enter filter,pressure drop. SPa on line 4 and Total Fan. pressure Won Une 5. B) Calculate Fan Adjustment and enter on Une 8. C) Calculate Adjusted Fan Power Index and enter on Une 7. 1 TOTAL FAN SYSTEM POWER eftsSum Column F 12O 2 SUPPLY DESIGN AIRFLOW CFM 1,000 3 TOTAL FAN SYSTEM POWER INDEX Row 1/Raw 21 4 SPa 144 h 5 SPf g Fan AcQusbnent =1 SPa -1 SPf 144(l) 7 ADJUSTED FAN POWER'INDEX Line 3 x Line 81 0.120 I. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER, INDEX must not exceed 0:8 W/ctrn for Constant Volume systems. or 1:25 W/ahn for VAV systw, ITEM or SYSTEM TAG(S) PRESCRIPTIVE MEASURES Electric Resistance Heating 1 Heat Rejection System 2 Air .Cooled Chiller Limitation 3 T-24 Sectibn Capacity Exception Notes 144 144 h 144(l) 1. Total Installed capacity (MBtuhr) of all electric heat on this projectexctusive of electric auxigary heattor heat pumps. a electric heat is used, explain which exception(s) to Section(g) apply. 2. Are aenhifugal fan cooling towers used on this project? (Enter 'Yee or 'No") M centrl(ugal fan cooling towar are used, explain which exceptions) to Section 144(h) apply. 3. Total installed capacity (Ions),of ell.water and air cooled chillers under this permit If there are more than -100 Eons of aircooled.chWer capacity being, installed;; explain which axceptbn(s) to.Sedon 1144(l) apply. EnergyPro 4.4 by EnergySoft User Number 7746 Job Number. 9045.()0 Page: 17 of 19 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM Buildi 7/16/2009 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 911 Any appliance for which there is a California standard establlshed`in the. Appliance Efficiency Regulationsvill comply with ther applicable standard. §o15(a) Fan'type central furnaces shall not have a pilot light. §123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be Insulated In accordance with Standards Section 123.. 624 Air handling duct systems shall be installed and Insulated in compliance with Sections 601, 602, 603, 604, and 605, of the 2001 CMC Standards. Controls §122(9) Each space conditioning system shall be installed with one of the following: §122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall berInstalled with.an automatic time switch with an accessible manual override that allows operation of ths,system during oft hours for up to 4 hours. Tho time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours If power is interrupted; or 9122(9)1 B An occupancy sensor to cont rol.the operating period of the system; or F] f122(e)1C A4 -hour timer thatcan be manuallyy operated to control the -operating period of the system. Q §422(9)2 Each space conditioning system shall be Installed with controls that temporarily restart and temporarily operate the system as required to maintains setback heating and/or a setup cooling thermostat setpoint. 022(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or'dampere, that allow the supply of'heating or cooling to. be setback or shut offandependently of other Isolation areas; and shall be controlled by time control device as described above. §422(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85. degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least dsgrees F within which the supply of heating and cooling is shutoff or reduced to a minimum. 9122(c) Thermostats. shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint. stops accessible only to authorized personnel. a§112(b) Heat pumps shall be installed with controls:to.preventelectric resistance supplementary heater operation when the heating load can bemet by the heat pump alone. EnergyPro 4.4 by EnergySaft User Number. 7746 Job Number. 9045.00 Page:18 of 19 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE Addition to the Raquet Club Building 7/16/2009 Description Designer Enforcement Ventilation §121(e) Controls shall be provided Wallow outside air dampers or devices to be operated at the ventilation rates as speclfied on these plans. 922(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outsidealr Intakes and discharges of all space conditioning and exhaust systema: F §122(}) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings tothe outside, except for combustion'air openings. §121(f)1 Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1889); or ❑ §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20mechanical contractor, or(3) the person with overall responsibility for the. design of the ventilation system; or §t21(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous, basis and displaying that quantity on a readily accessible display divice; or §121(f)4 Another method approved bythe Commission. .Service Water Heating Systems 9I13(b)2 If a circulating hot.watersystsm Is Installed, it shall have a control capable of automatically turning off the circulating pump(s).when hot water is notrequired. §113(c) Lavatories, In restrooms ofpublic.facllities shall be equipped with. controls to limit the outlet temperature to 110 degrees f. EnergyPro 4! 4 by EnergySoft User Number. 7746 Job Number. 9045.00 Page:19 of 19