09-0777 (RC) Title 24I TITLE '24 REPORT I
Title 24 Report for:
Addition to the Raquet Club Building
3s5' Lu
Mn s,
Project Designer:
Curtis R. Shupq, Architect
72-880Fred Waring Drive, Suite A-5
Palm Desert, CA 92260
760-346-7354
Report Prepared By:
MRC Engineering
MRC Engineering, Inc.
72-880 Fred Waring Drive Suite C-11
Palm Desert, CA 92260
_ (760) 340-9005
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DArE q W11 o BY ob Number:
_7-17
9045.00
Date:
7/16/2009
The EnergyPro computer program has been used to perform the calculations summate In this compliance report This program has approval and is
authorized by the California Energy Commission for:use with both the Residential and: Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoftcom.
EnergyPro 4.4 by EnergySoft Job Number. 9045.00 User Number. 7746
JUL 1 7 200.9
Py.
Title 24 Report for:
Addition to the Raquet Club Building
3s5' Lu
Mn s,
Project Designer:
Curtis R. Shupq, Architect
72-880Fred Waring Drive, Suite A-5
Palm Desert, CA 92260
760-346-7354
Report Prepared By:
MRC Engineering
MRC Engineering, Inc.
72-880 Fred Waring Drive Suite C-11
Palm Desert, CA 92260
_ (760) 340-9005
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DArE q W11 o BY ob Number:
_7-17
9045.00
Date:
7/16/2009
The EnergyPro computer program has been used to perform the calculations summate In this compliance report This program has approval and is
authorized by the California Energy Commission for:use with both the Residential and: Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoftcom.
EnergyPro 4.4 by EnergySoft Job Number. 9045.00 User Number. 7746
TABLE OF CONTENTS I
Cover Page
1
Table of Contents
2
Form ENV -1-C Certificate of Compliance
3
Form ENV -3-C Overall Envelope Method
5
Form ENV -MM Envelope Mandatory Measures
12
Form MECH-1-C Certificate of Compliance
13
Form MECH-2-C Air & Water System Requirements
15
Form MECH-4-C HVAC Misc. Prescriptive Requirements
16
Form MECH-MM Mechanical Mandatory Measures
18
EnergyPro 4.4 by EnergySoft Job Number. 9045.00 User Number. 7748
[CERTIFICATE OF COMPLIANCE (Part 1 of 2) ENV -1-C
PROJECT NAME
DATE.
Addition. to the Ra uet Club Building
7/16/2009
PROJECT ADDRESS
79295 Rancho LaQuinta Di ine LaQuintsmg
;
PRINCIPAL DESIGNER - ENVELOPE 'TELEPHONE .
rl
udap,.ermit':# g
A� 0 _ .
Curtis R. Shupe, Architect 760-346-7354
DOCUMENTATION AUTHOR TELEPHONE
edrby/pate"" T
MRC Engineern , Inc. 760 340-9005
e;i,
GENERAL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
CLIMATE ZONE
7-16-09
997 Sq:Ft.
15
BUILDING TYPE
NONRESIDENTIALHIGH'
RISE RESIDENTIAL
HOTELIMOTEL GUEST ROOM
❑
,RELOCATABLE- Indicate:❑
Specific Climate -dist: , or
Ail Climates
PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION FXI ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit)
METHOD OF'ENVELOPE ❑ COMPONENT(EN.V-4;C) X OVERALL ENVELOPE(ENWI-C) ❑ PERFORMANCE
COMPLIANCE
STATEMENT OF'COMPLIANCE
This Certificate of Compliance lists -the building features and' performance specifications needed to comply with Title 24,
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements.
The documentation preparer hereby certifies that the document is accurate and complete.
DOCUMENTATION AUTHOR
SIGNATURE
DATE
MRC En ineerin
The Principal Envelope Designer'hereby certifies that the proposed building design represented in this set of construction
documents,is.consistentwiththe other compliance formsand worksheets, with the specifications, and with any other
calculations submitted with this permit application. The proposed building has been designed to meet the envelope
requirements contained in Sections 110, 116 through 1181 and 140; 142, 143 or 149 of Title 24, Part 6.
Please check one:
❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this
document as the person responsible for its preparation; and' that I am licensed in the state of California as a civil engineer
or mechanical engineer, or I am a. licensed architect.
❑ I affirm that I am eligible under the exemption to Division 3-of'the Business and'Professions Code by Section 5537.2 or
6737.3 to sign this document as the person responsible for its preparation; and that I am a
licensed contractor performing this work.
❑ 1. affirm that I am eligible. under Division 3 of the Business and Professions Code to sign this document because it pertains
to a structure or type of work described as: exempt pursuant to Business and Professions Code Sections 5537, 5538, and
6737.1.
PRINCIPAL ENVELOPE DESIGNER- NAME
SIGNATURE
DATE
LIC. 0
Curtis R. Shue Architect
ENVELOPE MANDATORY MEASURES
Indicate location on plansaof Note Block for Mandatory, Measures
ENVELOPE COMPLIANCE FORMS & WORKSHEETS Ghedc.box If worksheet.is;induded
For detailed instruclions on the:use of this and all Energy Efficlency.S.tandards:compliance forms, please, refer to the Nonresidential Manual published
the Califomia. EnergycCommission.
ZENVA-C: Certificate of Compliance., Required on, plans forrall submittals. Part 2 may be.incorporated in schedules on plans.
OENV-,2-C: UsedEnvelope Component compliance method
ZENV-3-C: Used with Overall Envelope Compliance method
❑ENV -4-C:, Optional. Use for minimum skylight requirements for large enclosed spaces.
EnergyP'm 4.4 by EnergySoft 'User Number 7746 Job Number. 9045:00 Page:3 of 19. .
CERTIFICATE OF COMPLIANCE (Part2 of 2) ENV -1-C
PROJECT NAME DATE
Addition to the Raquet Club Buildinq 7/16/2009
110
Surface
Type
Area I
U -Fac:
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond:
Status
Joint Appendix
IV Reference
Location i Comments
1
Roof
431
0.051
R-19
R-0.
00
20
Loewen DbI/Wd Mtldad Low -E
ADDITION EAST
ADDITION S
2
Wall
44
0:074
R-19
R-0.0
0
90
New
09-A5
ADDITION EAST
3
Wall
-261,
0.074,-1
New
R-0 0
180
90
IWIndow
09-A5
ADDITION EAST
4
Wall
2
0.074,
R-19
R-0.0
90.
90
Now
09-A5
ADDITION EAST
5
Wall
4
0.074
R-19
R-0:0
0
90
New
09-M
ADDITION WEST
6
Wall
34
0.074
,R-19
R-0:0
180
90
New
09-A5
ADDITION WEST
7
Wall
32
0.0741
RA9
R-0.0
270
90
New
09-A5
ADDITION WEST
8
Roof
562
0.051
RA9
R-0.0
270
20
New
02-A5
ADDITION WEST
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
R
FI�1 More than or equal to 10,000 sqA of elle" k fenestration area must Include a label certificate eyher.issued by,NFRC; or provide a CEC Default Label Certificate using the default Wactors from
I I !`.M.d..4. Tahle l IA -A -I R r tie�sfs ehnll Aa OU f N.n nl.nww �e n.wie w �nwn A,w,- -M- -w- s e . -
#
Tvpe
Area U -Fac'
SHGC2
Act.
Azm.
Cond.
Stat.
Glazing, Too
Location/
Comments
1
Window
Front
N
46 0.340 NFRC
0.28 NFRC
0
New
Loewen DbI/Wd Mtldad Low -E
ADDITION EAST
2
Window
Rear
S
64 0.340 NFRC,
0.28 NFRC
180
New
Loewen DbI1Wd Mtldad Low -E
ADDITION EAST
3
Window
Left
E
330 0.340 NFRC i 0.28 NFRC
90
New
Loewen DbINVd Mtldad Low -E
ADDITION EAST
4
IWIndow
Front
N
4 .0.340 NFRC
0.28 NFRC
01
New
Loewen DbVWd Mtldad Low -E
ADDITION WEST'
5
Window
Rear
S
64 0.340 NFRC
0.28 NFRC
180
New
Loewen DbINVd Mtldad Low -E
ADDITION WEST
6
Window.
Right
W
450 0.340 NFRC
0.28 NFRC
270
New
Loewen DbUWd Mtldad Low -E
ADDITION WEST
1010
0.1 4.0
0
0.0
0.0 0
6
Roll -down Blind or Slats
0.13
8.0 56.0
4.0 0.1
4.0
4.0
0.1 4D
0
0:0
0.0 0
1 uiactor Type: -116-A Default Table from Standards, Table NF1 Default Table from the ACM Manuel Appendbt NFRC Labeled value.
2 SHGC Type: 118.8 DefaultTable from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
#
Exterior Shade Type
SHGC
Window
Hgt, Wd.
Overhang
L n. Hgt. LExt.RExt.
Left Fin
Dist. Len. H t.
Right.
Dist.
Fin
Lan. H t
1
Roll -down Blind or Slats
0.13
8.0 6.0
4.0 0.1
4.0
4.0
0.1 4.0
0
0:0
0.0 0
2
Roll -down Blind or Slats
0.13
8.0, 9.0
10.0 0.1
10.0
10.0
0.1 4.0
0
0.0
0.0 0
3
Roll -down Blind or Slats
0.13
8.0' 24.0
4.0 :0.1
4.0
4.0
0.1 4:0
0
0.0
0.0 0
4
Roll -down Blind or Slats
0.13
8.0 6.0
4.0 0.1
4.0
4.0
0.1 4.0
0
0.0
0.0 0
5
Roll -down Blind or Slats
0.13
8.0 8.0
10.0 0.1
10:0
1010
0.1 4.0
0
0.0
0.0 0
6
Roll -down Blind or Slats
0.13
8.0 56.0
4.0 0.1
4.0
4.0
0.1 4D
0
0:0
0.0 0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
U The proposed bu6dtrlg b in climate zones 2 through 15 and contain an enclosed Space with floor area greater Clan 25,000 ft2, a coiling height greater than 15 feet, and an LPD for general
OgAtng of at Mast 0.6 WHt2. See Sector 1143(c}It this box is checked, EW44 must be filled auL when sutunKdng under the Proscrlptlw Cmnpllance Approach.
EnergyPro 4.4 by EnergySoft User Number: 7746 Job Number. 9045.00 Page:4 of 19 1
OVERALL ENVELOPE METHOD (Part 1 of 7) ENV -3 -
IC
WINDOW AREA CALCULATION
A. DISPLAY PERIMETER 135 ft x o;ff =
810 ft DISPLAY AREA
B. GROSS EXTERIOR WALL AREA 1,206 fe X 0.40 =
482 R:40% GROSS WALL AREA
C. ENTER' LARGER OF A OR B 1,206
810fe MAXIMUM STND. AREA
D. ENTER PROPOSED WINDOW AREA
1,0021 ftp PROPOSED AREA
E. WINDOW WALL RATIO = Proposed Window Area Divided by Gross Exterior Wall Area = 83.0.8%
F. WEST DISPLAY PERIMETER 54 ft x 6 ft =
3241 ie WEST DISPLAY AREA
G. WEST EMRIOR WALL AREA 482 Ric 0:40 =
193 fe 40% WEST WALL AREA
H. ENTER THE LARGER OF F'AND G 482
324 Ile MAX. STND. WEST AREA
1. ENTER PROPOSED WEST WINDOW AREA
4501 fe PROPOSEDWEST AREA
J. WESTWINDOW WALL RATIO = Proposed West Window. Area Divided by West Exterior Wall Area = . 93.367
Combined Values for North, East and South Walls
K. WEIS DISPLAY PERIMETER (A - F) 81 ft x 6 ft =
4$6 fe WEIS; DISPLAY AREA
L. NIEIS'EXTERIOR WALL AREA (B - G) 724 ft'x 0.40 =
290 ft, 40% WEIS AREA
M. ENTER LARGER OF K OR L 724
2901 fe MAX. STAND. WEIS AREA
N. PROPOSED N/FJS WINDOW AREA (D -1)
552 fe PROPOSED NOS AREA
I&qNDOW ADJUSTMENT
O. IF D >-C andfor if.l > H, PROCEED TO CALCULATION STEPS 1 OR 2, AS APPROPRIATE, FOR THE WINDOW AREA.ADJUSTMENT..IF NOT,
GO TO THE SKYLIGHT AREA TEST, ENV -3-C, PART 2 OF 7.
1. IF I < H: Use the calculated Window adjustment forall walls.
MAXIMUM.STANDARD PROPOSED WINDOW
WINDOW
AREA. from C AREA from D
ADJUSTMENT FACTOR
2..IF I a H: Calculate one window adjustment factor (WAF) for the West well.
a. Calculate;the WAF for the West wall.
MAX.: STANDARD WEST PROPOSED WEST
WEST WINDOW
AREAfro AREA from I
ADJUSTMENT FACTOR
7732741 s 145011
0.720
b. If N > M: Calculate.the WAF for the North, East and South walls.
MAX. STANDARD WETS PROPOSED WEIS
NIEJS WINDOW
AREA from M AREA from N
ADJUSTMENT FACTOR
290 _F 552
=1 0.525
GO TO PART 7 TO CALCULATE ADJUSTED AREAS.
EnergyPro 4:4 by ErwgySaft User Number. 7746 Job Number. 9045.00 Page:5 of 19
OVERALL ENVELOPE METHOD (Part 2 of 7) ENV -3-C
PROJECT NAME DATE
Addition to the Ra uet Club Buildin 7/16/2009
A. ATRIUM HEIGHT 10 ft
GROSS STANDARD ALLOWED
ROOF AREA SKYLIGHT AREA
B. IF <= 55 FT 99T fex 0.05 - 501 ft
C. IF:,- 55 FT fex 0:10 - ft:
D. PROPOSED SKYLIGHT AREA Q it°
IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED
TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PART 3 OF 7.
1. IF PROPOSED SKYUGHT AREA:,—STANDARD SKYLIGHT AREA:.
PROPOSED SKYLIGHT AREA SKYLIGHT
STANDARMSKYLIGHT AREA (IF E = 0 ENTER 1) ADJUSTMENT FACTOR
GO TO PART 7 TO CALCULATE ADJUSTED AREAS.
EnergyPro 4.4 by EnergySoft User Number. 7746 Job NumberM45.00 Page:B of 10
OVERALL ENVELOPE METHOD (Part 3 of 7) ENV -3-C
PROJECT NAME
Addition to tl
OVERALL HEAT LOSS
A
.ASSEMBLY NAME
(e.g. Wall -1, Floor -1)
Roof
North Wall
Window
South Wall
Window
East Wall
Window
North Wail
Window
South Wall
Window
West Wall
Window
I Roof
B C D I I E
PROPOSED
STANDARD
AREA
HEAT
CAP.
U-
FACT:
ACM
JA IV Ref.
UA
(B X D)
435
0.051
0.05102-A5
50
22.2
44
40
0.074109-M
19.0
3.3
46
3.4
0.340
0.470
15.6
26
0:102
0.074
09-A5
1.9
64
48
0.340
4.9
21.8
25
19.9
0:074
09-A5
1.9
330
0.470
0.340
158
112.2
42
324
0.074
09-A5
3.1
48
0.3401
16.3
35
0.074
09-A5
2.6
64
0.340
21.8
32
0.074,09-A5
2.4
450
0.340
153.0
562
0.06102-A5
28.7
DATE
F
G H
STANDARD
AREA'
(Adjusted)
U-
FACT.
UA
(F'X G)
435
0.051
22.2
50
0.102
5.0
40
0.470
19.0
34
0:102
3.4
561
0.470
26.5
64
0:102
6.6
291
0.470
136.6
48
0:102
4.9
421
0.470
19.9
43
0:102
4.4
56
0.470
26.5
158
0.102
16.
324
0.470
152.3
562
0.051128.7
1) In climate zones 1' and 16 the Insulating R -value of continuous; *if Window and/orSkoight'Area Adjustment Is 407 This Page Total
472
Insulation materials Installed above•theiroof waterproof Required, useAdjusted Areas from,Part 7 of 7. g
membrane shall be multiplied times 0.8,befoie choosing the
table column for determining assebmly U -factor. See Faohrotes, 407 Building Total 472
Tables N.1 through IV.71n the Joint Appendices.
EnergyPro 4.4 by EnergySoft User Number. 7746 Job Number. 9045:00 Page:7 of 19 1
OVERALL ENVELOPE METHOD (Part 4 of 7) ENV -3-C]
ECT NAME
to h ue i
L
DATEA,dd*tion
612009RALL
HEAT GAIN FROM CONDUCTION
A
B C I D I E F
G
H I I J
ASSEMBLY NAME
(e.g. Wall -1, Floor -1)
PROPOSED
STANDARD
AREA
TF
HEAT
CAP.
U.
FACT.
ACM
JJL IV Ref.
HEAT
GAIN
(BxCxE)
AREA'
(Adjusted)'
U-
FACT.
TF
HEAT
GAIN
(GxHxl)
Roof
435
55
0.05
02-A5
1,220
435
0.051
55
1,220
North Wall
44
55
0.074
09-A5
179
50
0.102,
55
278
Window
46
55
0.340
860
40
0.470
55
1,047
South Wall
26
55
0.074
09-A5
106
34
0.102
55
189
Window
64
55
0.340
1,197
56
0.470
55
1,457
East Wall
25
55
0.074
09-A5
102
64
0.102
55
362
Window
330
55
0340
6,171
291
0.470
55
7,511
North Will
42
55
0.074
09-A5
171
48
0.102
55
268
Window
48
55
0.340
898
42
0.470
55
1,092
South Wall
35
55
0.074
09-A5
142
43
0.102
55
239
Window
64
55
0.340
1,197
56
0.470
55
1,457
West Wall
32
55
0.074
09-A5
130
158
0.102
55
886
Window
450
55
0.340
8,415
324
0.470
55
8,375
Roof
562
55
0.05
02-A5
1,576
562
0.051
55
1,576
1.) In climate zones 1 and 16 the insulating R -value of continuous
Insulation materials installed above the roof waterproof membrane
shell be muttlplied times 0.8 beforechoosingthe table column for
determining assembly U -factor. See. footnotes, Tables N:1
hroe h IV in the JointAppendices.
I
'If Window and/or Skylight Aiea Adjustment Is
Required, use Adjusted Areas from Part'6 of 7.
-22,3641i,25 957
Subtotal Subtotal
EnergyPro 4.4 by EnergySoR User Number. 7746 Job Number: 9045.00 Pagw a of 19
NAME
Addition to the Raouet Club Build
(Part 5 of 7) ENV -3 -Cl
DATE
ROOF ABSORPTANCE CALCULATION
R-21 Roof Cathedral
CHECK APPLICABLE BOXES
Case 1 - Proposed YES NO
A
1. CRRC-1 Certified?
2. Is the thermal emittance > 0.75?
3. Enter the' Initial reflectance ph* value:
4. Calculate a. = 0.94 - 0:7p=p
B C I D E F G
Go to 2.
Go to 3.
X
Go to 8.
Go to 5.
Go to 4. Insert value in calculation.
Enter calculated value In Column F below.
STANDARD
ASSEMBLY NAME
(e.g. Roof -1)
p w. ora =
a" =
WF
Case 2 - CRRC-1 Tested
Absorp
HEAT GAIN
[(BxCxDxExF)
S. Enter Initial reflectance & emitfance values from CRRC-1
,6. Calculate pwPw to . 0.448 + 1.121 pto+ 0.524 EM
7. Calculate a = 0.94 - 0.7 p m. P
U -Factor
EM = Go to 6. Insert values in calculation.
Go to 7. Insert,value inzalculation.
Enter calculated value In Column F below.
PM =
p RLP" =
a p" =
435
8. Not:CRRC-1 Tested
0.92
0. 51
For nonresidential low -sloped roofs:
For all other roofs:
[Rpm 00.87 Enter default value In Column F below.
8. = 0.73 Enter default value In Column F below.
Standard absorptance values for Column J are either
0,0510.73
For nonresidential low -sloped roofs:
For all other roofs:
' a m = 0.45 Enter standard value In Column J below.
am 0.73 Enter standard value in Column J below.
LQV_ERALL HEAT GAIN FROM
RADIATIOR
OPAQUE SURFACES
A
R
B C I D E F G
H I J K
PROPOSED
STANDARD
ASSEMBLY NAME
(e.g. Roof -1)
AREA
SF
WF
U-
FACTOR
Absorp
HEAT GAIN
[(BxCxDxExF)
AREA"
(ADJUSTED).
U -Factor
Absorp
HEAT GAIN
(CxDxHxfxJ)
Roof
435
123
0.92
0. 51
1,833
435
0,0510.73
1.833
Roof
562
0.92
nnsi
22811
sR2
n-nsi
n VA
,ARA
4 2 Subtotals are entered under-SubtOtar 4 200
SUBTOTAL In COLUMNS bend M of ENV4-C, Part SUBTOTAL
0 Of 7.,
EnergyPro 4.4 by EnergySoft User Number. 7746 Job Number. 9045.00 Pa .9 of 19
OVERALL ENVELOPE METHOD (Part 6 of 7) ENV -3-C
PROJECT NAME DATE
Addition to the Raauet Club Building 7/16/2009
IOVERALL HEAT GAIN FROM
RADIATIONFENESTRATION SURFACES
22,364
A
0
C D 1 E I F G I H I
J K L M
ININDOWISKYUGHT NAME
e.g. Wind -1, Sky -1) ORIENT.
WEIGHTING
FACTOR
PROPOSED
STANDARD
AREA
SF
t
SHGC
OVERHANG
4,200
HEAT GAIW
BxC:DxExH)
AREA
(ADJU8TED
RSHG a
or SHGC
SF
HEAT GAIN
BxJxKxL)
H
V
HN
OHF
Window N
0.61
46
123
0.28
4.0
8.1
0.49
0.85
818
40
0.40
123
1.215
Window S
1.27
64
123
Total Had Galin
62 924
EnergyPro 4.4 by EnergySoft User Number. 7746
Job: Number: 9045.00
1,232
56
0.31
123
2,729
Window E
1.07
330
123
0.28
4.0
8.1
0.49
0.63
7,674
291
1
123
11.854
Window N
0.61
48
123
42
0.40
123
1.268
WIndow S
1.27
64
123
0.2810.0
8.1
1.23
0.44
1,232
56
0.31
123
2,729
Window W
1.05
45C
123
324
0.31
1231
12972
1. From Fenestration Surfaces ENV -1-C, Part 2, .Column:G, or when'Column
Part 4 Subtotal
22,364
Part 4 Subtotal
25,957
H has a'C- Identifier, calculate using the center of glass value SHGCc in.
SHGCfen - .06 + (0.86xSHGCc) and enter value.
4.200
4,200
4. Proposed Heat Gain, Column I may be no greater than Standard Heat
Part 5 Subtotal
Part 5 Subtotal
Gain Column M.
3 .If Window and/or Skylight Area Adjustment is required, use adjusted area
Part 6 Subtotal
22.077
Part 6, Sul-
ubfrom
fromPart 6 of 7.
4. Only SHGCls used for.Skylights
48 64
Total Had Galin
62 924
EnergyPro 4.4 by EnergySoft User Number. 7746
Job: Number: 9045.00
Page:10 of 19
OVERALL ENVELOPE METHOD Part 7 of 7 ENV -3-C
NAME
ub Buildi
7/16/2009
WINDOW AREA - ADJUSTMENT CALCULATIONS
❑ CHECK IF NOT APPLICABLE'(See
Part 1 of 7)
ORIENTATION
E
F
G
WINDOW
ADJUST.
FACTOR
(From Part 1)
ADJUSTED
WINDOW
AREA
(D X E)
ADJUSTED
WALL
AREA
B - (F + C)
A
8
C
D
WALL NAME
(e.g. Wall -1, Wall -2)
GROSS
AREA
DOOR
AREA
WINDOW
AREA
N E S W
X] ❑ ❑ ❑
❑ ❑ IX ❑
❑ 0 ❑ ❑
X] 1:1 ❑ ❑
1:11:1 X❑ ❑
❑ ❑ ❑ ®
❑ ❑ ❑ ❑
❑ ❑ ❑ ❑
❑ ❑ ❑ ❑
❑ ❑ ❑ ❑
❑❑❑❑
❑❑❑❑
❑❑❑❑
❑❑❑❑
❑❑❑❑
❑❑❑❑
❑❑❑❑
❑❑❑❑
TOTALS
North Wall
90
0
46
0.880
401
50
South Wan
9.0
0
64
0.880
56
3
East wall
355
0
330
0.880
291
6
North Wall
90
0
48
0.880
42
48
South Wall
99
0
64
0.880
56
4
West Wall
482
0
450
0.720
324
158
EwWPm 4.4 by EmxgySoft User Number .7746 Job Number. 9045.00 Pagel 1 of 19
1,2061
01
1,00
N/A
8101
39
ISKYLIGHT AREA ADJUSTMENT CALCUUIIONS
FXICHECK IF NOT APPLICABLE (See Part 2 of 7)
D
E
F
SKYLIGHT
ADJUST.
FACTOR
(From Part 1)
ADJUSTED
SKYLIGHT
AREA
(C X D)
ADJUSTED
ROOF
AREA
(B - E)
A
B
C
ROOF NAME
(e.g. Roof -1,, Roof -2)
GROSS
AREA
SKYLIGHT
AREA
TOTALS
N/A
EwWPm 4.4 by EmxgySoft User Number .7746 Job Number. 9045.00 Pagel 1 of 19
ENVELOPE MANDATORY MEASURES ENV -MM
PROJECT NAME DATE
Addition to the Raquet Club Building I
7/16/2009
DESCRIPTION
Designer
Enforcement
0 6118(a) Installed insulating Material shall have been certified by the manufacturer to
comply.with the California Quality Standards for insulating material, Title 20,
Chapter 4, Article 8.
D 6118(c) All Insulating Materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 70T of Title 24, Part 2.
M§ 117(a) All Exterior Joints and openings in the building that are observable sources of air
leakageshall be caulked, Basketed, wentherstripped or otherwise sealed.
X❑ §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for glass doors
and fire doors).
§ 116(a)1 Manufactured Doors and Windows Installed shall have air infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products -must be labeled for U -value according to NFRC procedures.
§118(e) Demising Walls in Nonresidential Buildings:
The opaque portions of framed.demising walls in nonresidential buildings shall
have Insulation with an installed R -value of no less than R-18 between framing
members.
EnergyPro 4.4 by EnergySoft UserNumber'7746 Job. Number. 9045.00 Page:12 of 19
CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-1-C
PROJECT NAME
DATE OF PLANS
DATE
Addition to the Ra uet Club Building
7-16-09
7/16/2009
PROJECT ADDRESS
BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM
PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ®ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit)
79295 Rancho LaQuinta Ddne. LaQuints
COMPLIANCE
Building'Permit #
PRINCIPAL DESIGNER - MECHANICAL
TELEPHONE
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements.
MRC Engineeing Inc.
760-340-9.005
- - -�
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
MRC Engineering, lnc.
(760) 340-9005
sEdIbmernent,Agency
QIENEIRAIL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
CLIMATE ZONE
7-16-09
997 sq.Ft:
1 15
BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM
PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ®ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit)
METHOD OF MECHANICAL PRESCRIPTIVE ❑ PERFORMANCE
COMPLIANCE
PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED
OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications: needed to comply with Title 24,
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements.
The documentation preparer hereby certifies that the documenta ' n'is aocurat complet
DOCUMENTATION AUTHOR
SIGN
JDATE
G-
The Principal Mechanical Designer hereby certifies that the pro d building design represented in this set of construction
documents is consistent Wth the other compliance forms and sheets, with the specifications,. and with any other
calculations submitted with this permit application. The propos building has been designed to meet the mechanical
requirements contained in the applicable parts of Sections 100, 01, 102, 110 throughl 15, 120 through 125, 142, 144, and 145.
❑ The plans & specifications most the requirements of Part 1 (Sections 10-103x).
❑ The installation certificates meet the requirements of Part 1. (10-103a 3).
❑ The operation & maintenance Information meets the requirements of Part1 (10-103c).
Please check One: (These sectionsof the Business and Professions Code are printed in full in the Nonresidential Manual.)
❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the
person responsible for its preparation; and,that I;am licensed in the. State of California as a civil engineer, or mechanical engineer or I
am a licensed architect.
1 affirm that I am eligible under the exemption to Division 3 of the Business and. Professions Code by Section 5537.2 or 6737.3 to sign
this document as the person responsible for its preparation; -and that I am a.licensed contractor performing this work..
❑' I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code'to sign this document because it pertalnsto a
structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1.
PRINCIPAL MECHANICAL DESIGNER.- NAME L,11 DATE LIC. #
tit
7RE
I
MRC Enaineerinti Inc, AVX. b2.fM-.3 45Sr
INSTRUCTIONS C T
® MECH-1-C: Certificate of Compliance. Part 1, 2, 3 of 3 are required on 'plans for all submittals.
IN MECH-2-C: AirMater/Service/Water Pools. Requirements. Part 1 of 3,2 of 3, 3 of 3 are required for all submittals, but.may be on
plans.
0 MECH-3-C: Mechanical Ventilation and, Reheat is required for all: submittals with mechanical ventilation, but maybe on plans.
LN MECH-4-C: HVAC Misc. Prescriptive Requirements is required for all prescriptive submittals, but may be on plans.
❑ MECH-5-C: Mechanical Equipment Detalls are required for all performance submittals.
EnergyPro 4.4 by EnergySoft User Number. 7746 Job Number. 9045.00, Page:13 of 19
CERTIFICATE OF COMPLIANCE (Part 2 of 2) MECH-1-C
NAME
DATE
6/2009
uesigner:
This form Is to be used by the designer and attached to the plans. Usted below are,all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that.requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM, Manual that describes the test. Also Indicate the,person responsible1or performing the tests (i.e. the Installing contractor, design professional or an agent.
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope, of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed, building or space, ora new space -conditioning, system serving a
building or spaow Is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted,to the building department that certifies plans, spedticatlons, Installation
certificates, and operatina and maintenance. Information meet the requirements of Section 10-103(b) and Title 24 Part 6.
T TE ENT OF COLAPLIANCE
D MECH-2-A: Ventilation System Acceptance Document.
Variable Air Volume. Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
TestnWked on all New syslams both New Construction and Reboft
D'MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test requhed on all New systems both New Construction and Reboot
❑ MECH-4A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test requked on all Now systems both New Consbucdon and Retrofit Unita.mM economizers that are Installed at" factory and owfifled with the
commission do not require equipment Gesifng but do require construction Inspection.
D MECH-S-A: Air DistributionAcOaPtanceL Document
Equipment requiring acceptance testing
This test requked IF Me unit serves 5,000 V ofspace orfess and 25 6 amore or pre ducts araln noncondNioned or samicondrb oned space like an
attic New systems Met meet Ma above requkemerft Retrofit systems that meet the aboverawksments and elitw extend duds, replace ducts or
replace Me packaged urdt
D MECH4)-A: Demand Control Ventilation Acceptance Document
Equipment requiring acceptance testing
All new DCV controls installed on crew or existing packaged systems must be tested:
D MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VAV fen volume controls installad on new or existing systems must be lasted.
D MECH-6-A:-Hydronic System Control Acceptence;Document
-Variable Flow Controls Applies toduredand hot water systems.
Automatic Isolation Controls Applies to now balers and dialers and Me priniary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chlied and hot water systems Mat hove a design cspadty greater than or equal tc 500,000 Bbuhr.
-Water400p Heat Pump Controls
Applies to all new watadoop heat pump systems where the comWned1oop pumps are psefor Men, 5 hp.
-Variable Frequency Controls Applies ban new dlaftution pumps on new variable flowWled, hy&MIC heat pump.
or condenser wafer systems where Me pumps motors we pealer 9ren 5 hp.
Equipment uirin acceptance testing
EnergyPro 4.4 by EnergySoft_ User Number. 7746 Job Number. 9045.00 Page:14 of 19
AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
Addition to the Raouet Club Buildina 1 7/16/2009 1
ITEM OR SYSTEM TAG(S)
Number of Systems
MANDATORY MEASURES
Heating Equipment Efflclency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.432
Proposed Heating:Capactty 2
Calculated Sensible Cooling Capacity x 1.212
ProposedSensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressurs Reset (DDC only).
,Simultaneous Headcool
Economizer
Heating Air Supply Reset
Cooling .Air Supply Reset
Duct Sealing for Prescriptive Compllanceg
AIR SYSTEMS Central' orSin le Zone
ADDITION EAST ADDITION WEST
1 1
T-24
Section Reference on Plans or Specification
112(a)
7.70 HSPF
7:70 HSPF
112(a)
16.0 SEER / 13.0 EER
.180 SEER / 13.0 EER
112(b)
Yes
Yes
112(c), 115(a),
n/a
n/a
121(b)
Yes
Yes
121(b)
0 cfin
0 cfm
121(c)
No
No
121(c)
No
No
121(c), 122(e)
Prourammable.Switch
Proarammable Switch
122(e)
Heating & Cooling Required
Heating &Cooling Required
122
Auto
Auto
122
n/a
n/a
123
124
n/a
n%a
144. a & b
13,563 btuh
17,280 btuh
1441a & b
35,039 btuh
35,039 btuh
1441a & b
13,507 btuh
19,232 btuh
144 a & b
28,950 btuh
29,464 btuh
144 c
Constant Volume
Constant Volume
144 c
144 c
Yes
Yes
144 (d),
No
No
144 a
No Economizer
No Economizer
1.44
Constant Ternp
Constant Tem
144 (f)
Constant Temp
Constant Temp
144 k
No
No.
1: For each central and single none air systems (or group of similar units) fill In the reference to sheet numberandlor specification section and paregraph number where the
required features are documented. If a requirement Is notapplicabie, put "NW In the column.
2: Not required for hydronlc heating and cooling. Either enter, a value here or put In reference of plans and'spedficatons per footnote 1.
3: Enter Yes If System U: Constant Volume, Single zone; Serves <. sgft; Has > 25% duct in unconditioned space: Duct sealing is required4br Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
IMECHANICAL SIZING AND FAN POWER MECH-4-C
PROJECT NAME
DATE
Addition to the Ra uet Club Building
7/1.6/2009
SYSTEM NAME
ADDITION EAST
FLOOR AREA
435
FFA—N;*75ON
FAN DESCRIPTION
Supply Fan
B
DESIGN
BRAKE HP
0.062
C 0
E
F
EFFICIENCY
120
NUMBER
OF FANS
PEAK WATTS
B x E x 7461(C X D)
OT
DRIVE
40.2%
97.0%
1.0
120
6 Fan Adjustment =1 SPa,- iySPf
144(i)
ADJUSTED FAN POWER INDEX Line 3 x Line 6
0.120
11. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/ch for Constant Volume systems or 1.25W/cfin for VAV systems.
ITEM or SYSTEM TAG(S)
Total Adjustments
FILTER PRESSURE ADJUSTMENT EQUATION
A) If filter pressure drop is greater than 1 inch W.C. enter
filter pressure drop. SPa on line 4 and Total Fan pressure
SK on Line 5.
B) Calculate Fan Adjustment and enteron Line 6.
C) Calculate Adjusted, Fan Power Index and enter on Line 7.
1 TOTAL.FAN SYSTEM POWER(Watts, _Sum Column
120
2 SUPPLY DESIGN AIRFLOW CFM
1.,000
3 TOTAL. FAN SYSTEM POWER INDEX.(Row 1/Row 21
41 SPa
144 h
5 Ism
6 Fan Adjustment =1 SPa,- iySPf
144(i)
ADJUSTED FAN POWER INDEX Line 3 x Line 6
0.120
11. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/ch for Constant Volume systems or 1.25W/cfin for VAV systems.
ITEM or SYSTEM TAG(S)
PRESCRIPTIVE MEASURES
Electric Resistance Heating 1
Heat Rejection System 2
Air Cooled Chiller Limitation 3
T-24
Section
Capacity
Exception
Notes
144
144 h
144(i)
1. Total installed capacity, (MBbrlhr) of all electric heat on this project exclusive of electric auxillary heat for heat pumps. M.electric heat Is used, explain which exception(s) to Sectlon(g) apply.
2. Are centrifugal fan cooling towers used onlhis pro)ect? (Enter 'Yes" or 'Ne) R centrifugal fan cooling tower are used, explain which exception(s) to Section 144(h) apply.
3. Total installed capacity (tons)'of all,vrater and air cooled chillers under this,pennll. If there are more than 100 tons of air-cooled chiller rapacity being Installed, explain which exception(s) to Section
144(i) apply.
EnefgWro 4.4 by EnergySoft User Number,. 7746 Job Number. 9045.00 Page:16 of'19
MECHANICAL SIZING AND FAN POWER MECH-4C
PROJECT NAME
DATE
Addition to the Ra uet Club Building
7/16/2009
SYSTEM NAME
ADDITION WEST
FLOOR AREA
562
FAN POWER CONSUMPTION
FAN DESCRIPTION
SUPPIY Fan
B
DESIGN
BRAKE HP
0.062
C I D
Total Adjustments
F
EFFICIENCY
12O
NUMBER
FANS
PEAK WATTS
Bx E x 748 / (C X D)
MOTOR
DRIVEOF
40.2%
97.0%
1.0
120
g Fan AcQusbnent =1 SPa -1 SPf
144(l)
7 ADJUSTED FAN POWER'INDEX Line 3 x Line 81
0.120
I. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER, INDEX must not exceed 0:8 W/ctrn for Constant Volume systems. or 1:25 W/ahn for VAV systw,
ITEM or SYSTEM TAG(S)
Total Adjustments
FIR.PRESSURE ADJUSTMENT EQUATION
A) If filter pressure drop is greater than 1 inch W.C. enter
filter,pressure drop. SPa on line 4 and Total Fan. pressure
Won Une 5.
B) Calculate Fan Adjustment and enter on Une 8.
C) Calculate Adjusted Fan Power Index and enter on Une 7.
1 TOTAL FAN SYSTEM POWER eftsSum Column F
12O
2 SUPPLY DESIGN AIRFLOW CFM
1,000
3 TOTAL FAN SYSTEM POWER INDEX Row 1/Raw 21
4 SPa
144 h
5 SPf
g Fan AcQusbnent =1 SPa -1 SPf
144(l)
7 ADJUSTED FAN POWER'INDEX Line 3 x Line 81
0.120
I. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER, INDEX must not exceed 0:8 W/ctrn for Constant Volume systems. or 1:25 W/ahn for VAV systw,
ITEM or SYSTEM TAG(S)
PRESCRIPTIVE MEASURES
Electric Resistance Heating 1
Heat Rejection System 2
Air .Cooled Chiller Limitation 3
T-24
Sectibn
Capacity
Exception
Notes
144
144 h
144(l)
1. Total Installed capacity (MBtuhr) of all electric heat on this projectexctusive of electric auxigary heattor heat pumps. a electric heat is used, explain which exception(s) to Section(g) apply.
2. Are aenhifugal fan cooling towers used on this project? (Enter 'Yee or 'No") M centrl(ugal fan cooling towar are used, explain which exceptions) to Section 144(h) apply.
3. Total installed capacity (Ions),of ell.water and air cooled chillers under this permit If there are more than -100 Eons of aircooled.chWer capacity being, installed;; explain which axceptbn(s) to.Sedon
1144(l) apply.
EnergyPro 4.4 by EnergySoft User Number 7746 Job Number. 9045.()0 Page: 17 of 19
MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM
Buildi
7/16/2009
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
911 Any appliance for which there is a California standard establlshed`in the.
Appliance Efficiency Regulationsvill comply with ther applicable standard.
§o15(a) Fan'type central furnaces shall not have a pilot light.
§123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be Insulated In accordance with
Standards Section 123..
624 Air handling duct systems shall be installed and Insulated in compliance with
Sections 601, 602, 603, 604, and 605, of the 2001 CMC Standards.
Controls
§122(9) Each space conditioning system shall be installed with one of the following:
§122(e)1A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the
requirements of Section 112 (d)) shall berInstalled with.an automatic time switch
with an accessible manual override that allows operation of ths,system during
oft hours for up to 4 hours. Tho time switch shall be capable of programming
different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at
least 10 hours If power is interrupted; or
9122(9)1 B An occupancy sensor to cont rol.the operating period of the system; or
F] f122(e)1C A4 -hour timer thatcan be manuallyy operated to control the -operating period of
the system.
Q §422(9)2 Each space conditioning system shall be Installed with controls that temporarily
restart and temporarily operate the system as required to maintains setback
heating and/or a setup cooling thermostat setpoint.
022(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with
Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be
provided with isolation devices, such as valves or'dampere, that allow the supply
of'heating or cooling to. be setback or shut offandependently of other Isolation
areas; and shall be controlled by time control device as described above.
§422(a&b) Each space conditioning system shall be controlled by an individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the
control shall be adjustable up to 85. degrees F or higher. Where used for both
heating and cooling, the control shall be capable of providing a deadband of at
least dsgrees F within which the supply of heating and cooling is shutoff or
reduced to a minimum.
9122(c) Thermostats. shall have numeric setpoints In degrees Fahrenheit (F) and
adjustable setpoint. stops accessible only to authorized personnel.
a§112(b) Heat pumps shall be installed with controls:to.preventelectric resistance
supplementary heater operation when the heating load can bemet by the heat
pump alone.
EnergyPro 4.4 by EnergySaft User Number. 7746 Job Number. 9045.00 Page:18 of 19
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
PROJECT NAME DATE
Addition to the Raquet Club Building 7/16/2009
Description
Designer
Enforcement
Ventilation
§121(e) Controls shall be provided Wallow outside air dampers or devices to be operated
at the ventilation rates as speclfied on these plans.
922(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provided on the outsidealr Intakes and discharges of all space conditioning and
exhaust systema:
F §122(}) All gravity ventilating systems shall be provided with automatic or readily
accessible manually operated dampers In all openings tothe outside, except for
combustion'air openings.
§121(f)1 Air Balancing: The system shall be balanced In accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1889); or
❑ §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
Installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the installing licenced C-20mechanical contractor, or(3)
the person with overall responsibility for the. design of the ventilation system; or
§t21(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous,
basis and displaying that quantity on a readily accessible display divice; or
§121(f)4 Another method approved bythe Commission.
.Service Water Heating Systems
9I13(b)2 If a circulating hot.watersystsm Is Installed, it shall have a control capable of
automatically turning off the circulating pump(s).when hot water is notrequired.
§113(c) Lavatories, In restrooms ofpublic.facllities shall be equipped with. controls to limit
the outlet temperature to 110 degrees f.
EnergyPro 4! 4 by EnergySoft User Number. 7746 Job Number. 9045.00 Page:19 of 19