Loading...
04-3595 (AR) Title 24`l .;Y TITLE 24 REPORT r " ITY OF A QUiNTA Title 24 ReportlferILDI)NO & SAFETY DEPT. GARCIA ADDITIION APPRO1J ED 53-875 Avenida NavarrbDR CONST2. UCTION La Quinta, Ca 92253 DATE :�11 By Project Designer: Lendel Ventures, Inc. DBA Lench Design Group f P.O. BOX 450 LA QUINTA, CA 92253-0450 760/564-1866 Report Prepared By: VERNA LENCH Lendel Ventures, Inc P.O. Box -450 ` La Quinta, CA 92253-0450 (760) 564-1866 R Job Number: 3.1-1217 Date: 11/17/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This xogram has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy- Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 3.1-1217 User Number: 5454. TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary _ 7 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 13 Room Heating Peak Loads 15 Room Cooling Peak Loads 17 EnergyPro 3.1 By EnergySoft Job Number: 3.1-1217 User Number: 5454 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R ' GARCIA ADDITION 11/17/2003 Project Title Date 53-875 Avenida Navarro La Quinta Project Address Building Permit # Lendel Ventures, Inc (760) 564-1866 Plan check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) _ Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Wood Total Conditioned Floor Area: 1,212 f? Average Ceiling Height: 9.4 ft Total Conditioned Slab Area: 1,212 f? Building Type: (East) (check one or more) 0.60 X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ' ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component R-38 Roof (R.38.2x14.16) Slab On Grade Slab On Grade R-13 Wall w/1" EPS Solid Wood Door R-13 Wall (W.13.2x4.16) 1;J =1►143111 111rel►1 Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.028 Exterior Roof n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Wood 0.059 Exterior•Wall None 0.387 Exterior Door Wood 0.088 Exterior Wall Rharlinn tlavicac Type Orientation • • Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 20.0 0.70 0.83 None ❑ x❑ ❑ ❑X Front (East) 30.0 0.60 0.37 Bug Screen ❑ 191 ❑ ❑x Front (East) 6.0 0.46 0.37 Bug Screen ❑ X❑ ❑ ❑x Right (North) 26.0 0.61 0.39 Bug Screen ❑ X❑ ❑X❑ Rear (West) 6.0 0.46 0.37 Bug Screen ❑ X❑ ❑X❑ Left (South) 96.0 0.61 0.39 Bug Screen X❑ ❑ ❑ x❑ Rear (West) 40.0 0.74 0.37 Bug ScreenX❑ ❑ ❑X❑ 1-1 El El Q ❑❑ El 1:1 El El 1:1 1:1 El El Run Initiation Time: 11/17/0313:42:14 Run Code: 1069105334 EnergyPro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1217 Pa e:3 of 18 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R GARCIA ADDITION 11/17/2003 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnare 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 1 Central Furnace 80% AFUE Ducts in Attic 42 Setback HVA . Syst .m - -nn . 2 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack HVAC SystPm - 7nnP 1 Split Air Conditioner 12.0 SEER Durts in Attic 42 Sethack HVAC System - 7nnP 2 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type' Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -75-230 Small Gas Recircrrime+Temp L— 75,000 75 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES.- NO DUPLICATION PERMITTED! COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Lendel Ventures, Inc. DBA Lench Design Grou Address: P.O. BOX 450 A QUINTA CA 3-0450 Telephon : 60/564-186 Lic. #: ee lure) (date) cement Agency: Title/Firm: Address: Telephone: Name: VERNA LENCH Title/Firm: Lendel Ventures, Inc Address: P.O. Box 450 La Quinta, CA 92253-0450 Telephone: (760) 564-1866 - 7 --0 (signature) ( ate) EnergyPro 3.1 By EnergySoft User Number. 5454 Job Number: 3.1-1217 Pape:4 of 18 1 Certificate of Compliance: Residential (Addendum) CF -IR GARCIA ADDITION. 11/17/2003 Project Title Date Special Features and Modeling Assumptions . The local enforcement agency should pay special attention to the items specified.in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. - Plan Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC System - Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. i HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. pian Field The HVAC System "HVAC System- Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form The HVAC System "HVAC System - Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct . leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form_ VVVG. IVVJ IVJJ 7 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page:; of 18 `Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ❑X '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. .§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. FRI§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ❑X §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110IV 1 -13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. X❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A. or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape Dr tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. a§114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumenslwatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number. 5454 Job Number: 3.1-1217 Page:6 of 18 Computer Method Summary (Part 1 of 3) C -2R C-'ARIuIA ADDITION Project Title 11/17/2003 Date 53-875 Avenida Navarro La Quinta Project Address Building Permit # LP_ndel Ventures, Inc (760) 564-1866 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.53 3.24 0.29 Space Cooling 42.41 39.55 2.86 Domestic Hot Water 18.36 18.11 0.25 Totals 64.29 60.90 3.39 GENERAL INFORMATION Conditioned Floor Area: 1,212 Floor Construction Type: R Slab Floor Building Type: Single Fant Detached Raised Floor Building Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 1 ',430 Number of Stories: 1 Slab Floor Area: 1,212 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units HVAC: system - 7nnP 1 34ri 276 098 HVAC System - Zone 2 867 867 0.72 Zone Type Conditipned Cnnditinned Thermostat Type &-Pthank Rethank Vent Hat. Area OPAQUE SURFACES Solar Act. -Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R GARCIA ADDITION 11/17/2003 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Tilt 1 Skvlioht Front (Fast) 4.0 0 700_ 0_R3 q0 _n 2 Skylight Front (East) 4.0 0.700 0.83 90 0 3 Window Front (East) 30.0 0.600 0.37 90 90 4 Window Front (East) 6.0 0.460 0.37 90 90 5 Window Right (North) 6.0 0.610 0.39 0 90 6 Window Right (North) 6.0 0.610 0.39 0 90 L Ski dight Front (East) 4.0 0.700 0.83 90 8 Skylight Front (East) 4.0 0.700 0.83 90 0 6 Skvllght Front (East) 4.0 0.700 0.83 90 0 1Q Window Right (North) 4.0 0.610 0.39 0 90 11 Window Right (North) 4.0 0.610 0.39 0 90 12 Window Right (North) 6.0 0.610 0.39 0 90 13. Window Rear (West) 6.0 0.460 0.37 270 gQ 14 Window Left (South) 96.0 0.610 0.39 180 90 15 Window Rear (West) 40.0 0.740 0.37 270 90 Glazing Type Skylight - Dual Glaze Skylight - Dual Glaze Summit 5500 Al DP Low E Summit 5500 Al DP Low E Summit 5500 Al DP Low E Summit 5500 Al DP Low E S_k5dight - Dual Glaze Skylight - Dual Glaze Sk5dight - Dual Glaze Summit 5500 At DP Low E Summit 5500 Al DP Low E Summit 5500 At DP Low E Summit 5500 Al DP Low E Summit 5500 Al DP Low E Summit 5500 Al DP Low E Location/ Comments Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 None 1.00 8 None 1.00 9 None 1.00 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 8.0 12.0 8.0 0.1 8.0 8.0 15 Bug Screen 0.76 8.0 5.0 6.0 0.1 6.0 6.0 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Paae:8 of 18 1 Computer Method Summary (Part 3 of 3) _ C -2R GARCIA ADDITI Project Title 11/17/2003 Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter —41 0.76 0.0 0 Zone 1 Slab Perimeter 11 0.76 0.0 0 Zone 2 Slab Perimeter 94 0.76 0.0 0 Zone 2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFXducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 1 Central Furnace 801 AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 2 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -75-230 Small Gas Recirc/Time+Temp _ 1 75.000 75 0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 11/17/03 13:42:14 Run Code: 1069105334 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page:9 of 18 Computer Method Summary (Addendum) C -2R GARCIA ADDITION 11/17/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justitication and documentation submitted. IPlan I Field The DHW System "A.O. SMITH FPS -75-230" Enerqv Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. I The HVAC System "HVAC System - Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. I I I HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "HVAC System - Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HEIRS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form - The HVAC System "HVAC System - Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HEFTS rater must provide verifification of the TXV, or'measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 2" is using reduced duct leakage to comply and must have diagnostic site tesfing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 10 of 18 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 71 PROJECT NAME DATE GARCIA ADDITION 11/17/2003 SYSTEM NAME FLOOR AREA HVAC System - Zone 1 345 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Lstent CFM I Sensible 330 4,921 0 106 4,758 0 246 238 0 0 0 0 0 0 0 0 0 246 1 238 5413 0 5234 YORK H4DH042S06 23,626 12,450 64,000 Total Adjusted System Output 23,626 12,450 64,000 (Adjusted for Peak Design Conditions) TIME OF'SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.8 OF 69.8 OF 112.2 OF O Supply Air Ducts Outside Air 0 cfm 112.0 of Supply Fan Heating Coil 1400 cfm ROOMS 69.8 of 70.0 of POOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 74.2 64A of 74.2 / 64.1 of 60.0 / 59.2 of eSupoly Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 60.2 / 59.3 of 1400 cfm 58.E% R.H. ROOMS 74.2/64.10F 74.0/64.0 OF h Return Air Ducts 4 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page:11 of 18 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE GARCIA ADDITION 11/17/2003 SYSTEM NAME FLOOR AREA HVAC System - Zone 2 867 :ATING SYSTEM PSYCH 26.0 of 69.3 of Outside Air 0 cfm Supply Fan 855 cfm 69.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 22 10,614 0 150 12,905 0 531 645 0 0 0 0 0 0 0 0 0 531 645 11,675 OI 14195 YORK H4DHO60SO6 42,136 0 75,000 Total Adjusted System Output x2,136 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.3 OF 151.70F Heating Coil 1% Return Air Ducts '4 Supply Air Ducts 151.0 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111,0 77.6 of 74.6 ! 50.7 of 74.6 ! 50.7 of 28.3 ! 26.4 of Supply Air Ducts Outside Air O` 0 cfm Supply Fan Cooling Coil 28.9 / 26.8 of 855 cfm 14.2% R.H. ROOMS 74.6/50.7 of 74.0150.5 of h Return Air Ducts '4 I EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 12 of 18 1 ROOM LOAD SUMMARY --71 PROJECT NAME GARCIA ADDITION DATE 11/17/2003 SYSTEM NAME HVAC System - Zone 1 FLOOR AREA 345 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 330 4,921 0 330 4,921 0 106 4,758 PAGE TOTAL 1 3301 4,9211 011 106 4,758 TOTAL 330 4,921 0 106 4,758 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 13 of 18 ROOM LOAD SUMMARY PROJECT NAME GARCIA ADDITION DATE 11/17/2003 SYSTEM NAME HVAC System - Zone 2 FLOOR AREA 867 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING 'EAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 221 10,614 0 221 10,614 0 150 12,905 PAGE TOTAL 121 10,6141 0 150 12,905 TOTAL 1 221 10,614 0 150 12,905 EnergyPro 3.1 ByEnergySoft User Number: 5454 Job Number: 3.1-1217 Page:14 of 18 ROOM HEATING PEAK LOADS Project Title Date GARCIA ADDITION 11/17/2003 Room Information Desi n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 345 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 4 758 Infiltration: r 1.00 x 1.064 X 345 x 8.0o x 60] x I c `schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,758 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 15 of 18 337.0 x X x X X X X X X X X X X X X X X X x X x X X X X X x X X X X x x X X X x x x 0.0280 x x x X X X X X x x x x X x x X x X X x x x X x x x x x x x x x X x x x X x x 44.0 = = = = = = = = = = _ = = _ = = = c 415 8.0 0.7000 44.0 246 perimeter = 41.4 44.5 ;,842 263.4 0.0585 44.0 678 20.0 0.3872 44.0 341 30.0 0.6000 44.0 792 6.0 0.4600 44.0 121 12.0 0.6100 44.0 322 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 4 758 Infiltration: r 1.00 x 1.064 X 345 x 8.0o x 60] x I c `schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,758 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 15 of 18 ROOM HEATING PEAK LOADS 71 Project Title Date GARCIA ADDITION 111/17/2003 Room Information . Desi n Conditions Room Name zone 2 Time of Peak Jan 12 am Floor Area 867 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value Z�T of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Pace Total: 12 905 Infiltration: 1 1.00 x 1.064 x 867 x 10.00 x 6] x _ chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,905 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 16 of 18 855.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x X X X 0.0280 X X X X X X X X X X x X X X X X X X X X X X X x X X X X X x x X X X X x X x X 44.0 = = = = = = = = = o c = = = 1,054 12.0 0.7000 44.0 370 perimeter = 104.8 44.5 4,664 782.0 0.0585 44.0 2,013 110.0 0.6100 44.0 2.952 110.0 0.0885 44.0 428 6.0 0.4600 44.0 121 40.0 0.7400 44.0 1,302 Items shown with an asterisk (') denote conduction through an interior surface to another room. Pace Total: 12 905 Infiltration: 1 1.00 x 1.064 x 867 x 10.00 x 6] x _ chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,905 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1217 Page: 16 of 18 RESIDENTIAL ROOM COOLING LOAD SUMMARY GARCIA ADDITION 11/17/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 1 740F 112°F 38°F Conduction Area U -Value DETD 1 Btu/hr X (Skylight) 55.0 = Window 6050 SH 519 X (East) 38.0 = Window 4016 XO 213 X 4.0 34.6 = 580 533 X 30.0 34.6 = 902 268 X 6.0 38.0 = 180 684 X 6.0 38.0 = 39 105 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 2 600 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF. SC Btu/hr Skylight (Skylight) _ SkIdoght (Skylight) Window 6050 SH (East) Window 1016 4 FO (East) Window 4016 XO (North) Window 4016 XO (North) 1 4.0 152 0.954 580 ( 0.0 1 30.0 ( 0.0 x x x x x x x x x 1 + + + + + + + + + 4.0 x x x x x x x x X 152)X )X )X x x x )x )x )Y 0.954 = = = = = = 580 ( 0.0 1 4.0 152 0.954 580 ( 0.0 1 30.0 73 0.412 902 ( 0.0 1 6.0 73) 0.41 180 ( 0.0 1 6.0 15) 0.434 39 ( 0.0 1 6.0 15) 0.434 39 ( ( ( _.___ Sched. Page Total 2 321 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 345 x 0.00 Watts/sqft x 3.41 BtuhMatt = 0 Occupants 1.00 x 345 x C Btuh/OCC. / 20.00 sgft/OCc. = 0 Receptacle 1.00 x 345 x O-OOC Wafts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 345 x O-OOC Wafts/sgft x 3.41 Btuh[Waft = 0 Infiltration: �� x � x � x x � / 60] ^ _ Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4 921 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 345 x 0 Btuh/occ. / 20 000 sqft/occ. = 0 Receptacle 1.00 x 345 x 0.000 Watts/sgft x 3.41 Btuh/Waft = o Process 1.00 x 345 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o Infiltration: ched le x Air Latent x Area x Ceiling Height x ACH 00 / 60] Q010N0000 = Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 _By Energ Soft User Number: 5454 Job Number: 3.1-1217 Page: 17 of 18 RESIDENTIAL ROOM COOLING LOAD SUMMARY GARCIA ADDITION 11/17/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction -38 Roof R.38.2x14.16 k li ht - Dual Glaze R-13 Wall w/1 " EPS ummit 5500 Al DP Low E R-13 Wall W.13.2x4.16 Summit 5500 Al DP Low E Summit 5500 Al DP Low Area U -Value X DETD1 55.0 38.0 34.6 38.0 34.6 38.0 38.0 Zone 2 740F 112°F 380E Btu/hr 1,317 319 1,583 2,550 337 105 1,125 1. Design Equivalent Temperature Difference (DETD) Page Total 7 336 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight (Sk)light) SkIdoght (Skylight) Sk li ht (Skylight Window 2020 XO (North) Window 2020 XO (North) Window 3020 XO (North) Window 1016 4 FO (West) Window 12080 SLDG DR (South) Window 2680 2 FR DR (West) 0.954 580 ( 0.0 X x x x X x x x X 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + + 4.0 X X X x X X X X x 152) X x x x x x )1. 0.954 = = = = = = = = = 580 ( 0.0 4.0 152) 0.954 580 ( 0.0 4.0 152) 0.954 580 ( 0.0 4.0 15) 0.434 26 ( 0.0 4.0 15) 0.434 26 ( 0.0 6.0 15) 0.434 39 ( 0.0 6.0 73))--. 0.412 180 ( 96.0 0.0 32)y 0.434 625 ( 23.5X 16.5X 7)} 0.41 641 ( Sched. PE-ge Total 3 278 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 867 x 0.00C Watts/sgft X 3.41 Btuh/Waft - 0 Occupants 1.00 X 867 X Btuh/oCC. / 20 000 sgft'occ. = 0 Receptacle 1.00 x 867 x 0.00 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 867 x 0.00 Watts/sgft x 3.41 Btuh/Waft = 0 Infiltration: �� x � x � x x � / 60] Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10614 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 867 x 0 Btuh/occ. / 20 000 sgfVocc. 0 Receptacle 1.00 X 867 x 0.000 Watts/sgft x 3.41 Btul ]Watt = 0 Process 1.00 x 867 x 0.000 Watts/sqft x 3.41 BtutlWaft = 0 Infiltration: chedulle x Air Latent x Area 86 x Ceiling Height x ACH 00 / 60] QOA0000 = Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1217 Page: 18 of 18 xavier urbina architect. 4986 paseo segovia irvine, calif. 92612 (949) 856-0706 r-ITV �� �� w��� �1 S DESIGN CRITERIA AND SPWIFIEUMN' 6 BUILDING & SAFETY DEPT. Code: 1997 UBC APPROVES,' FOR 1 C�ONS- �*R! Seismic: Zone 4 ` 9j.9�`�N:• 0j Wind: Basic wind speed 70 mph, exposure `� F Soil. Allowable soil bearing pressure 1,000 psf Steel: ASTM A36, Fy = 36ksi for structural steel (flagpole tube sections) ASTM 615, Grade 40 for #3 and #4, Grade 60 for #5 and larger Lumber: Douglas Fir-Larch, 19% moisture content 2x joists and rafters.-................................. #2 or tetter 4x; 6x, 8x beams and headers... ...... .#1 or better Plates, blocking, and studs..... . ..:...........Stud g.- ade or better Plates in contact with concrete.....................Pressure treated Glue-laminated beams: Combination 24F-V4 Species, DF/DF Wood connectors: Simpson Strong-Tie, or approved equal Dead load: Live load: GaCt�ti� �aaio ' xavier urbina architect 4986 paseo segovia irvine, calif. 92612 (94°3) 413- 0345 " �EaM 1�E5lGnI " I PATI A �M._ ''W �4 x 5, � h= 218 - x I, 5 l b� Z Ql,13AM l ;. x ►L or-. F AV x21, 54S,-9 A16 ,oK 4741 �M , 6PRu► 4-x 12 ov. 14, �. vb4/low - �."Ib -- I =b" x 1=bk 12" �M.� �82��laoe 2, �2 ---� I ` �''x �! 8,►X 111, w�(�)� t.F-NcE{ vk i164 440u p C �� �a�cla PAtto • xavier urbina architect 4986 paseo segovia irvine, calif. 92612 (949) 856-0706 _ - - Lateral Analysis Wind: P = CeC.gQsl Ce = ,1.06 (0-15') Cq = .8. wWr) NOT A WToilk Qs = 13 P= 1.06x.8x13x1'= 11.02 - P.= 11.02 x = Seismic: E'= pEh + Ev Ev 0 ' p = 2 - 20 =a <_ 1. (1 min) M1 .5 x 10/24,V 1pe t • Eh=V=3x.44x1 x w =.24w✓ 5.5 , T o , • 1 LAW 64 Omw CIROU P (3) 4 AU(A PAT