BPOL2016-0148 Structural Calcs, COP 14�A TRr C-' '� RrAL E���GIr� EE�41Ir ��G� I�fC, 77570 Springfield Lane, Suite "D" _ Telephone. (760) 360-9998 Palm Desert, CA 92211 Fax: (760) 360-9903 Structural Calculation For Velarde Residence At Lot 312 At The Hideaway 53-389 Via Bellagio La Quinta, CA. CITY OF LAQUINTA BUILDING & SAFETY DEPT. PPR VE® FOR CONST UCTION DATE ' *27 Ulf Type Of Proiect: Residential Addition — Water Feature (10/12/2016) I Designer: Ochoa Design Associates GHA �� AgA tib, c q� NO. 067613 Date: April 3, 2015 Design by: R.A. JN:150215 kNRUCTURAL GINEERING, INC. SHEET: General Requirements JOB NO.: 150215 DATE: 10/12/2016 CLIENT: Velarde Residence GENERAL REQUIREMENTS 1. Work performed shall comply with the following: 2. These General Requirements unless otherwise noted on plans or specifications. 3. Building Code - CBC 2013, IBC 2012 4. All applicable local, State and Federal Codes, Ordinances, Laws, regulations and Protective Covenants governing the site of work. ENGINEERING SERVICES 1. Design 26" and 20" Water Feature adjacent to Existing Footing. 2. Section "A -A": Entry Fountain adjacent to footing (+26"). 3. Detail "1": Entry Fountain adjacent to footing (+26"). 4. Detail "2": Entry Fountain in the Courtyard. S. SOILS INFORMATION: Soils Report prepared by Sladden Engineering (760) 863-0847 Report No. 544-14075, 14-03-113, Dated March 27, 2014. Owner/ Contractor accepts all liability for compaction and subsidence of underlying soils. Soils Classification = Sand, Silty Sand Max. Soil Bearing Pressure = 2000 PSF Passive Pressure = 200 PSF/FT Coeff. of Friction = 0.35 Equiv Fluid Pressure = 35 PCF Resistivity = Moderatel Severe Potential 6. CONCRETE (GUNITE) AND MASONRY STRENGTH: Water Feature: Pc = 4500 PSI (28 -day Compressive Strength) 2500 PSI for structural calculations TYPE 5 Cement (Sulfate Resistant) Special Deputy Inspection Req'd. f'm = 1500 PSI (Masonry Strength) 7. STEEL: Fy = 40 KSI, Grade 40, ASTM A615, #3 Rebars or Greater. 8. BASIS OF DESIGN: CODE: International Building Code (IBC), 2012 Edition California. Building Code (CBC), 2013 Edition International Conference of Building Officials ASCE 7-10, Minimum Design Loads for Buildings STEEL: Manual of Steel Construction, Allowable Stress Design (AISC 341-10), 14th Edition CONCRETE: Building Code Requirements for Structural Concrete (ACI 318-11) MASONRY: TMS 402-11, ACI 530-11, ASCE 5-11 & IBC 2012 WOOD: National Design of Specifications for Wood Construction (NDS -2012), ANSI/NFoPA, 2012 Edition, National Forest Products Association 9. FACTORED LOAD COMBINATIONS FOR REQUIRED STRENGTH DESIGN: ACI 318-11, Appendix C - Alternate Load and Strength Reduction Factors (Eq. C.9-4) U = 1.4D + 1.7L + 1.7H (or 1.4F) (Eq. C.9-2) U = 0.75 (1.4D+1.7L) + 1.0E (or 1.OW) where, E = Earthquake W = Wind D = Dead Load L = Live Load H = Lateral Earth F =Fluid STRUCTURAL ENGINEERING, INC. PARTIAL SHEET: Water Feature (Addition) JOB NO.: 150215 DATE: 10/12/2016 CLIENT: Velarde Residence STRUCTURAL ENGINEERING, INC. SHEET: Water Feature (Addition) JOB NO.: 150215 DATE: 10/12/2016 CLIENT: Velarde Residence NOTES: 1. The (28 days) concrete compressive strength, f'c, shall be min 2500 psi. 2. The specified compressive strength of masonry, f'm, shall be 1500 psi. $„ 8'I I I — • Iri T #4 HORZ BARS @ (E) WALL LO 24" 0/C. (TYP.) (N) 8" CMU WALL SOLID GROUTED 11f #4 VERTICAL BARS @ 16" O/C. (TYP.) SECTION A -A AT WATER FEATURE CMU WALL SCALE: NTS CONCRETE SLAB OR PAVERS BY OTHERS ° 0" 101, N 0 /\�//\�//\�//\�//\�//\� 011. \ \ \ \ \ \ #4 BARS @ 8" OIC. (E) FOOTING 90% SOIL COMPACTION (N) FOOTING #4 BARS @ 12" O/C. (TYP.) SECTION A -A AT WATER FEATURE CMU WALL SCALE: NTS �j:;t:;j- A. STRUCTURAL ENGINEERING, INC SHEET: Water Feature (Addition) JOB NO.: 150215 DATE: 10/12/2016 CLIENT: Velarde Residence NOTE: The (28 days) concrete compressive strength, fc, shall be min 2500 psi. WATER FEATU #3 HORIZONTAL BARS @ 12" #3 BARS @ 6" O/C. (TYP CONT. #3 BARS @ 6" 0/C (TYP. #3 BARS @ 6" —1— (TYP.) Zh WATER FEATURE DETAIL AT EXISTING FOOTING SCALE: NTS RA Structural Title Velar0e Residence Page: 1 Job # : Dsgnr: R.A. Date: 18 OCT 2016 ASTRUCTURAL Description.... QENGINEUING Free Standing CMU wall for Water Feature Residence-(150215)\03-Structural\RA\10-12-16 (Addition -W Criteria 14 psf OK Retained Height = 1.50 it Wall height above soil = 5.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 ft Surcharge Loads 14 psf OK Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning 2,000 psf Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 20 psf Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary 0.300 Wall Stability Ratios Masonry Overturning = 9.60 OK Sliding = 0.00 OK Total Bearing Load = 1,755 lbs ...resultant ecc. = 8.05 in Soil Pressure @ Toe = 14 psf OK Soil Pressure @ Heel = 828 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 20 psf ACI Factored @ Heel = 1,159 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 15.2 psi OK Allowable 75.0 psi Sliding Calcs Lateral Sliding Force less 0 % Passive Force less 0 % Friction Force Added Force Req'd ....for 1.5 Stability 83.6 lbs _ - 0.0 lbs _ - 0.0 lbs = 83.6 lbs NG = 0.0 lbs OK Cantilevered Retaining Wall Fs oil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 62.5 psf/ft Passive Pressure = 300.0 psf/ft Soil Density, Heel = 100.00 pcf Soil Density, Toe = 0.00 pcf FootingIlSoil Friction = 0.000 Soil height to ignore Wind (W) for passive pressure = 0.00 in Lateral Load Applied to Stem 1.4 Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) 0.00 ft (Service Level) Wind on Exposed Stem = 25.0 psf (Service Level) at Back of Wall = Adjacent Footing Load 1.4 psi = Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil ft = at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 Wind acts left-to-right toward retention side. 1.4 psi = Stem Construction psi = 2nd Bottom 91.50 in= 3.75 5.00 Stem OK Stem OK in= Design Height Above Ftg ft = 1.50 0.00 ASD Wall Material Above "Ht" = Masonry Concrete Design Method Thickness = = ASD 8.00 LRFD 10.00 D AS : Rebar Size Rebar Spacing = = # 4 16.00 # 4 10.00 Rebar Placed at = Center Center 6) t o /G Design Data fb/FB + fa/Fa = 0.372 0.128 = e n , O I I I �� J� n / A Total Force @ Section S Service Level lbs= 125.0 0 • ^ a gra Qi Strength Level lbs = 12.5 Moment.... Actual Service Level ft-# = 312.5 Strength Level ft-#= 443.8 Moment..... Allowable ft-#= 839.5 3,464.1 Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E CBC 2013,ACI 1.200 1.600 1.600 1.000 1.000 Service Level Strength Level Shear..... Allowable Anet (Masonry) Rebar Depth 'd' Masonry Data fm Fs Solid Grouting Modular Ratio'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy psi= 1.4 psi = 0.2 psi = 44.9 75.0 int= 91.50 in= 3.75 5.00 psi= 1,500 psi = 20,000 = Yes = 21.48 psf = 78.0 125.0 = 1.000 in= 7.60 = Medium Weight = ASD psi = 2,500.0 psi = 40,000.0 _�' RA Structural Title Velarde Residence Page: 2 Job #: Dsgnr: R.A. Date: 18 OCT 2016 STR CTL'RAL Description.... =r.NciNer:Flni�; ' Free Standing CMU wall for Water Feature This Wall In File: J:\2015 Projects\Velarde Residence-(150215)\03-Structural\RA\10-12-16 (Addition -W RetalnPro (c)1987-2016, Build 11.16.07.15 License: KW -06059894 Cantilevered Retaining Wall Code: CBC 2013,ACI 318-11,ACI 530-11 Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.0316 in2/ft (4/3) * As: 0.0421 in2/ft Min Stem T&S Reinf Area 0.360 in2 200bd/fy : 200(12)(5)/40000 : 0.3 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of: Required Area: 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area : 0.24 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.016 in2/ft #6@ 22.00 In #6@ 44.00 in Footing Dimensions & Strengths Footing Design Results Toe Width = 0.00 ft Toe Heel Heel Width = 4.17 Factored Pressure = 20 1,159 psf Total Footing Width = 4.17 Mu': Upward = 0 1,376 ft-# Footing Thickness = 13.00 in Mu': Downward = 0 2,084 ft-# lbs ft Mu: Design = 0 707 ft-# Key Width = 0.00 in Actual 1 -Way Shear = 0.00 15.21 psi Key Depth = 0.00 in Allow 1 -Way Shear = 0.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 10.00 in fc = 2,500 psi Fy = 40,000 psi Heel Reinforcing = # 4 @ 8.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 6.50 @ Btm: 3.00 in Toe: Not req'd: Mu < phi'S'lambda"sgrt(fc)"Sm Heel: Not req'd: Mu < phi'5'lambda*sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 1.17 in2 Min footing T&S reinf Area per foot 0.28 in2 /it If one layer of horizontal bars: If two layers of horizontal bars: #4@ 8.55 in #4@ 17.09 in #5@ 13.25 in #5@ 26.50 in #6@ 18.80 in #6@ 37.61 in Summa of Overturnin & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 208.6 ' 0.86 179.6 Soil Over Heel = 500.1 1.67 833.5 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = -125.0 5.08 -635.4 • Axial Live Load on Stem = = Soil Over Toe = Surcharge Over Toe = Total 83.6 O.T.M. -455.8 Stem Weight(s) = 577.5 3.69 2,133.3 Earth @ Stem Transitions= _ = Footing Weighl = 677.1 2.08 1,410.8 Resisting/Overturning Ratio = 9.60 Key Weight = Vertical Loads used for Soil Pressure = 1,754.7 lbs Vert. Component = Total = 1,754.7 lbs R.M.= 4,377.6 ' Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. RA Structural Title Velaroe Residence Page: 3 R Job # : Dsgnr: R.A. Date: 18 OCT 2016 AtiTRUCTURAL Description.... ENGINEUINC. Free Standing CMU wall for Water Feature This Wall in File: J:\2015 Projects\Velarde Residence-(150215)\03-Structural\RA\10-12-16 (Addition-W (1967.2016, Build 11.16.07.15 Licensee: KWW-08059894 Cantilevered g Ctild Retainin Wall Code: CBC 2013,ACI 318-11,ACI 530-11 License: License To: RA STRUCTURAL ENGINEERING Tilt 7 Horizontal Deflection at Ton of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wail (approximate only) 0.042 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. 0 M 6" wl #4@ 16" y Solid Grout 10" w/ #4 @ 10" f -25.00pst (Service -Level) �Pp= 0.00# L N N CL n rn o 0 n m 84#