Loading...
14-0353 (SFD) Revision 1 Title 24BUILDING -ENERGY ANALYSIS REPORT ` PROJECT: S MR. & MRS. GEORGE V,ELARDE 53389 VIA BE'_LAGIO La Quinta, Ca 92253 a Project Designer: OCHOA DESIGN ASSOCIATES 73626 Highway 111 Palm Desert! Ca 92260: b . too (760)77 3 6605 Report Prepared by: Santiago Lopes-Ocam ;CITY OF LA QUINT Santiago Lopez-Ocam o BUILDING & SAFETY DEPT. P.o. Box f 018 APPROVED La'Quinta,'Ca 92247 FOR CONSTR CTION 760.485.8927 .WE r RECEIVED Job Number: LQ040515 MAY 14 2015 ; �{Cffy OF VEDate: COMMUNITYDEOPMENT 4/5/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is authorized by the California Energy Commission for use with both the Re sidential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySot. LLC — www.energysoft.com. _ t, Ener_g7t 6.5 by Ener_gySoft User Number: 5732 ID: LQ040515 1 TABLE OF CONTENTS Cover Page 1 Table of Contents 2. Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 17 Form MF -1 R Mandatory Measures Summary 19 HVAC System Heating and Cooling Loads Summary 23 i j i EnergyPro 6.5 by EnergySoft Job Number: ID: LQ040515 User Number: 5732 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Description: Title 24 Analysis Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Input File Name: VELARDE - T24 040515.xm1 CF1 R -PRF -01 Page 1 of 14 GENERAL INFORMATION 01 Project Name VELARDE Building Complies with Computer Performance .-•. r� 3 t �"a `t�"T� ° f `` 02 Calculation Description Title 24 Analysis 02 This building incorporates features that require field testing and/or�verificatior-by certifiedHERS rater'unidei the supervision of a CECapproved HERS provider. 03 Project Location 53389 VIA BELLAGIO ' „Y *lu 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3c (710) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.5 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2)4642 15 Number of Zones 5 16 Slab Area (FT 2) 4642 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT?) N/A 21 Glazing Percentage (%) 23.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance .-•. r� 3 t �"a `t�"T� ° f `` 02 This building incorporates features that require field testing and/or�verificatior-by certifiedHERS rater'unidei the supervision of a CECapproved HERS provider. 03 This building incorporates one or more Special`Feiturtes shown below w`P ' „Y *lu ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.24 2.90 -0.66 -29.5% Space Cooling 108.33 93.60 14.73 13.6% IAQ Ventilation 1.60 1.60 0.00 0.0% Water Heating 5.53 5.53 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 117.70 103.63 14.07 12.0% J Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-1116:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 J CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE CFI R-PRF-01Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Page 2of14 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy TDV energy consumption for lighting and c on-site renewable energy system. Total Energy (kTDV/f2-yr)* n fdr energy use components: included in the performE not'regulated by Title 24, -Part 6�(such as dorn"tic' �`- r -1 r- K: * mow.' Reference Energy Use 155.43 • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 Number of Dwelling Project Name Conditioned Floor Area (ft2) Units VELARDE 4642 1 04 compliance approach for -I :es and consumerelectri � R�M R pwr argy Design Rating .141.36 05 Number of Bedrooms I Number of Zones 15 5 Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-02272015-710 rd Design Building (Energy Budget) and the annual accounting for the annual TDV energy offset by an Margin 14.07 06 Number of Ventilation Cooling Systems 0 Percent Improvement 9.1% 07 Number of Water Heating Systems 1 HERS Provider: CaICERTS inc. Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 3of14 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Bed 2 - Work Out AREA Conditioned HVAC System - Zone 1 (4 01 712 11 DHW Sys 1 Master Bedroom Conditioned HVAC System - Zone 2 (3 02 992 11 DHW Sys 1 Great Room & Gallery Conditioned HVAC System - Zone 3 (2 03 1102 13 DHW Sys 1 Dining -Kitchen -Pantry -Lau Conditioned HVAC System - Zone 4 (1 04 1030 12 DHW Sys 1 Guest Bedrooms Conditioned HVAC System - Zone 5 (5 05 806 11 DHW Sys 1 1 r �.` HERS PROS E Registration Number: 215-NO088215A-000000000-0000 Registration Date/Time: 2015-05-1116:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (W) Tilt (deg) Ri/NW Bed 2 - Work Out AREA R-21 Wall 315 Right 214.5 42 90 Re/SW Bed 2 - Work Out AREA R-21 Wall 225 Back 132 40 90 Le/SE Bed 2 - Work Out AREA R-21 Wall 135 Left 214.5 0 90 Fr/NE Bed 2 - Work Out AREA R-21 Wall 45 Front 379.5 0 90 Roof Bed 2 - Work Out AREA R-38 Roof Attic - w/Radia 178 Roof 2 Bed 2 - Work Out AREA R-38 Roof Attic - w/Radia 178 Roof 3 Bed 2 - Work Out AREA R-38 Roof Attic - w/Radia 178 Roof 4 Bed 2 - Work Out AREA R-38 Roof Attic - w/Radia 178 Ri/NW 2 Master Bedroom R-21 Wall 315 Right 665.5 54 90 Re/SW 2 Master Bedroom R-21 Wall 225 Back 247.5 90 90 Le/SE 2 Master Bedroom R-21 Wall 135 Left 16.5 0 90 Fr/NE 2 Master Bedroom — R-21 Wall 45 Front 33 0 90 Roof 5 Master Bedroom f r R-38 Roof Attic- w/Radia,'—^ /f _ 248 Roof 6 Master Bedroom y i R-38 Roof Attic - w/Radia' _ ? '~ ' 1 ` 248 Roof? Master.Bedroom �R-38RoofAttic -w/Radia' z - / ' �� 248 Roof 8 Master Bedroom R-38 Roof Attic - w/Radia� ? !` ' ,; "`,, 248 Ri/NW 3 Great Room & Gallery R-21 Wall 315 Right 84.5 0 90 Re/SW 3 Great Room & Gallery R-21 Wall 225 Back 340 225 90 Le/SE 3 Great Room & Gallery R-21 Wall 135 Left 520 114.5 90 Fr/NE 3 Great Room & Gallery R-21 Wall 45 Front 383.5 167 90 Roof 9 Great Room & Gallery R-38 Roof Attic - w/Radia 275.5 Roof 10 Great Room & Gallery R-38 Roof Attic - w/Radia 275.5 Roof 11 Great Room & Gallery R-38 Roof Attic - w/Radia 275.5 Roof 12 Great Room & Gallery R-38 Roof Attic - w/Radia 275.5 Ri/NW 4 Dining -Kitchen -Pantry -Lau R-21 Wall 315 Right 416 59.5 90 Re/SW 4 Dining -Kitchen -Pantry -Lau R-21 Wall 225 Back 216 100 90 Le/SE 4 Dining -Kitchen -Pantry -Lau R-21 Wall 135 Left 722 46.5 90 Roof 13 Dining -Kitchen -Pantry -Lau R-38 Roof Attic - w/Radia 257.5 Roof 14 Dining -Kitchen -Pantry -Lau R-38 Roof Attic - w/Radia 257.5 Roof 15 Dining -Kitchen -Pantry -Lau R-38 Roof Attic - w/Radia 257.5 Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Description: Title 24 Analysis Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 5of14 Roof 16 Dining -Kitchen -Pantry -Lau R-38 Roof Attic - w/Radia 03 04 257.5 06 07 Ri/NW 5 Guest Bedrooms R-21 Wall 315 Right 452.8 82.5 90 Re/SW 5 Guest Bedrooms R-21 Wall 225 Baric 22 0 90 Le/SE 5 Guest Bedrooms R-21 Wall 135 Left 423 31.5 90 Le/S Guest Bedrooms R-21 Wall 180 - specify - 42.1 13.6 90 Fr/NE 4 Guest Bedrooms R-21 Wall 45 Front 278.2 15.8 90 Roof 17 Guest Bedrooms R-38 Roof Attic - w/Radia 3.5 201.5 0.85 Roof 18 Guest Bedrooms R-38 Roof Attic - w/Radia Ventilated 3.5 201.5 0.85 Yes Roof 19 Guest Bedrooms R-38 Roof Attic - w/Radia 201.5 Roof 20 Guest Bedrooms R-38 Roof Attic - w/Radia Ventilated 3.5 201.5 0.85 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Bed 2 - Work Out AREA Attic RoofBed 2 - Work Out AREA „� Ventilated: -1 3.5 ;moi.€ 0. I _ - 0.85 Yes - No �o^ !' �»...� ."Y"� - - Attic Master Bedroom Attic RoofMaster Bedroom Venteed,E # , —=i 3'Sj j ' `� 0.1, i ! - 0.85 Yes No AtticRoofGreatRoom&1,1�fAttic "Ven Yes No Great Room &Gallery Galle ' �, 3.5 [r 0.1 0.85 AtticAttic RoofDining-Kitchen-Pantry- Ventilated 3.5 0.1 0.85 Yes No Dining -Kitchen -Pantry -Lau Lau Attic Guest Bedrooms I Attic RoofGuest Bedrooms Ventilated 3.5 0.1 0.85 Yes No Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 6 of 14 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U -factor SHGC Exterior Shading 2046 Fix Window Ri/NW (Right -315) --- - 1 9.0 0.26 0.21 Insect Screen (default) 6056 Casement Window Ri/NW (Right -315) --- - 1 33.0 0.27 0.19 Insect Screen (default) (2) 2680 FrDr Window Re/SW (Back -225) -- - 1 40.0 0.27 0.17 Insect Screen (default) 4046 Casement Window Ri/NW 2 (Right -315) --- - 1 18.0 0.27 0.19 Insect Screen (default) 1620 Fix Window Ri/NW 2 (Right -315) - -- 1 3.0 0.26 0.21 Insect Screen (default) 1620 Fix 2 Window Ri/NW 2 (Right -315) - -- 1 3.0 0.26 0.21 Insect Screen (default) 1426 Fix Window Ri/NW 2 (Right -315) --- --- 1 3.3 0.26 0.21 Insect Screen (default) 1626 Fix Window Ri/NW 2 (Right -315) --- --- 1 3.8 0.26 0.21 Insect Screen (default) 1426 Fix 2 Window Ri/NW 2 (Right -315) -- -- 1 3.3 0.26 0.21 Insect Screen (default) 1656 Fix Window Ri/NW 2 (Right -315) - -- 1 9.8 0.26 0.21 Insect Screen (default) 1656 Fix 2 Window - Ri/NW 2 (Right -315) -- --- 1 9.8 0.26 0.21 Insect Screen (default) 2080 Sidelite Window Re/SW 2 -(Back -225) - r^- - r-�t 2 Q- - 8.0 r 1 16.0 - 0.27 - 0.10 Insect Screen (default) (2) 2680 FrDr 2 Window r- Re/SW 2 (B6ck-225) r ° t ; " �. 5.0 �., 8.0 ; 1 a`t / r 40.0 0.27 0.17 Insect Screen (default) Sidelite 2 Wndow r Re/SW 2 (Back -225) 8.0 t ` 12080 . �16.Q 0.27 0.10 Insect Screen (default)2.0 9020 Transom Window Re/SW 2� Back -225) , y �^ -y 'R- f m " + 1 :?18.0 0.29 0.11 Insect Screen (default) (3) 58100 Window Re/SW 3 (Ba6k-225) 17.0 10.0 1 170.0 0.26 0.17 Insect Screen (default) (2) 26110 Window Re/SW 3 (Back -225) ---- --- 1 55.0 0.26 0.17 Insect Screen (default) 2650 Fix Window Le/SE 3 (Left -135) -- --- 1 12.5 0.26 0.21 Insect Screen (default) 3066 Fix Window Le/SE 3 (Left -135) --- -- 1 19.5 0.26 0.21 Insect Screen (default) (2) 3080 FrDr Window Le/SE 3 (Left -135) -- -- 1 48.0 0.27 0.17 Insect Screen (default) 6026 Transom Window Le/SE 3 (Left -135) -- -- 1 15.0 0.29 0.11 Insect Screen (default) 3066 Fix 2 Window Le/SE 3 (Left -135) -- -- 1 19.5 0.26 0.21 Insect Screen (default) 5066 Fix Window Fr/NE 3 (Front -45) -- - -- 1 32.5 0.26 0.21 Insect Screen (default) 1620 Fix 3 Window Fr/NE 3 (Front -45) --- -- 1 3.0 0.26 0.21 Insect Screen (default) 80120 Window Fr/NE 3 (Front -45) -- -- 1 96.0 0.71 0.73 Insect Screen (default) 5066 Fix 2 Window Fr/NE 3 (Front -45) -- -- 1 32.5 0.26 0.21 Insect Screen (default) 1620 Fix 4 Window Fr/NE 3 (Front -45) --- -- 1 3.0 0.26 0.21 Insect Screen (default) 3066 Fix 3 Window Ri/NW 4 (Right -315) --- --- 1 19.5 0.26 0.21 Insect Screen (default) (2) 40100 Window Ri/NW 4 (Right -315) --- -- 1 40.0 0.26 0.17 Insect Screen (default) Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 7 of 14 (4) 26100 Window Re/SW 4 (Back -225) 10.0 10.0 1 100.0 0.26 0.17 Insect Screen (default) 2650 Fix 2 Window Le/SE 4 (Left -135) -- --- 1 12.5 0.26 0.21 Insect Screen (default) 2650 Fix 3 Window Le/SE 4 (Left -135) --- -- 1 12.5 0.26 0.21 Insect Screen (default) 2020 Fix Window Le/SE 4 (Left -135) --- --- 1 4.0 0.26 0.21 Insect Screen (default) 2020 Fix 2 Window Le/SE 4 (Left -135) -- --- 1 4.0 0.26 0.21 Insect Screen (default) 3046 Casement Window Le/SE 4 (Left -135) --- --- 1 13.5 0.27 0.19 Insect Screen (default) 3066 Fix 4 Window Ri/NW 5 (Right -315) --- --- 1 19.5 0.26 0.21 Insect Screen (default) (2) 3080 FrDr 2 Window Ri/NW 5 (Right -315) --- -- 1 48.0 0.27 0.17 Insect Screen (default) 6026 Transom 2 Window Ri/NW 5 (Right -315) -- - 1 15.0 0.29 0.11 Insect Screen (default) 5046 Casement Window Le/SE 5 (Left -135) --- - 1 22.5 0.27 0.19 Insect Screen (default) 2046 Fix 2 Window Le/SE 5 (Left -135) - - 1 9.0 0.26 0.21 Insect Screen (default) 1646 Fix Window Le/S ( specify --180) -- - 1 6.8 0.26 0.21 Insect Screen (default) 1646 Fix 2 Window Le/S (- specify --180) -- - 1 6.8 0.26 0.21 Insect Screen (default) 3646 Casement Window Fr/NE 4 (Front -45) -- - 1 15.8 0.27 0.19 Insect Screen (default) DOORS -gyp- Overhang Left Fin Right Fin Window Depth 01-'02 Left Extent Right Extent 03 04 �4� Name +�� t �: �' ✓ , �+,` Side;of Building tom- r ;"j Area (ft2) U -factor 3080 Dr '� `t, f..,� 1:7, "SFr/NE ` * , 24.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 2080 Sidelite 4 0.1 4 4 0 0 0 0 0 0 0 0 0 (2) 2680 FrDr 2 4 0.1 4 4 0 0 0 0 0 0 0 0 0 2080 Sidelite 2 4 0.1 4 4 0 0 0 0 0 0 0 0 0 (3) 58100 18.45 2 3 3 0 0 0 0 0 0 0 0 0 (4) 26100 15.45 2 4.58 4.58 0 0 0 0 0 0 0 0 0 Registration Number: 215-NO088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 8 of 14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Bed 2 - Work Out AREA 712 0.1 None 0.8 No • Cavity/Frame: no insul. /2x4 Top Chrd Attic RoofBed 2 - Work Out 992 0.1 2x4 Top Chord of Roof Truss @ 24 0.8. No Roof Deck: Wood Siding/sheathing/decking AREA Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Dining -Kitchen -Pantry -Lau 1030 0.1 None 0.8 No • Inside Finish: Gypsum Board Guest Bedrooms 806 0.1 None 0.8 No • Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 R-38 Roof Attic - w/Radia attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Bedroom Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd Attic RoofGreat Room & _ 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Gallery Attic Roofs Wood Framed Ceilingr ;l> :_ in' O.C.- -" r none 0.644 Roofing: Light Roof (Asphalt Shingle) Cavity/ Frame: no insul. / 2x4 Top Chrd Attic t�. _ 2x4 Top Chord of Roof Truss@ 24 ; ! I t # c ` _ , t � Roof Deck: Wood Siding/sheathing/decking RoofDinin Kitchen -Pant Lau Attic Roofs -,Wood Framed Ceiling-' ^' `'--` s in. O.C. " � - � ' none ` 0.644' Roofing: Light Roof (Asphalt Shingle) 1—i te— i ` Z% ' >E , Cavity / Frame: no insul. / 2x4 Top Choi 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGuest Bedrooms Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade Bed 2 - Work Out AREA 712 0.1 None 0.8 No Slab -on -Grade 2 Master Bedroom 992 0.1 None 0.8. No Slab -on -Grade 3 Great Room & Gallery 1102 0.1 None 0.8 No Slab -on -Grade 4 Dining -Kitchen -Pantry -Lau 1030 0.1 None 0.8 No Slab -on -Grade 5 Guest Bedrooms 806 0.1 None 0.8 No Registration Number: 215-NO088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Page 9 of 14 Calculation Description: Title 24 Analysis Input File Name: VELARDE - T24 040515.xml III -DING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 Name DHW Sys 1 - 1/1 WATER HEATERS 01 Name DHW Heater 1 02 03 04 05 06 System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Standard DHW Heater 1 1 •0% 02 03 04 05 06 07 08 Tank Exterior Tank Volume Energy Factor or Insulation Standby Loss Heater Element Type Tank Type (gal) Efficiency Input Rating R -value (Fraction) Natural Gas - —;Small Storage 50 0.6 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION Vk, 01 _ _ 03 _ _ Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use DHW Sys 1 - 1/1 — --' -- - - Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 _ CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 06 07 Recirculation Central DHW Control Distribution HERS Provider: CaICERTS inc. Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 06 Fan Name Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Project Name: VELARDE Air Distribution System 1 Input File Name: VELARDE - T24 040515.xml Calculation Description: Title 24 Analysis HVAC Fan 3 Air Distribution System 3 HVAC Fan 4 SPACE CONDITIONING SYSTEMS HVAC Fan 5 Air Distribution System 5 01 02 03 04 SC Sys Name System Type Heating Unit Name Cooling Unit Name Cooling Component 1:Heating Component 1:Air Other Heating and Cooling Heating Component 1 Cooling Component 1 Distribution System 1:HVAC Fan 1:1 System Cooling Component 2:Heating Component 2:Air Other Heating and Cooling Heating Component 2 Cooling Component 2 Distribution System 2:HVAC Fan 2:1 System Cooling Component 3:Heating Component 3:Air Other Heating and Cooling Heating Component 3 Cooling Component 3 Distribution System 3:HVAC Fan 3:1 System Cooling Component 4:Heating Component 4:Air Other Heating and Cooling Heating Component 4 Cooling Component 4 Distribution System 4:HVAC Fan 4:1 System 5:Heating Component 5:Air Other Heating and Cooling Heating Component 5 Cooling Component 5 rC-ooliingentCompon Distribution System 5:HVAC Fan 5:1 System HVAC - HEATING UNIT TYPES • 02 - - - •Name -. - - �. v . Heating Component 1 ,� i' f rCntrlFurnace 'Fuef fired centPal furnace Heating Component 2 '�C_ntrlFurnace ;Fuel-firedcentral `furnace 6 Heating Component 3 �,,��{ �t CntrlFurnaceY, Fuetfired central fumace^t Heating Component 4 ..� CntrlFurnace - Fuel-fired' central furnace Heating Component 5 CntrlFurnace - Fuel-fired central furnace Registration Number: 215-NO088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 CFI R -PRF -01 Page 10 of 14 05 06 Fan Name Distribution Name HVAC Fan 1 Air Distribution System 1 HVAC Fan 2 Air Distribution System 2 HVAC Fan 3 Air Distribution System 3 HVAC Fan 4 Air Distribution System 4 HVAC Fan 5 Air Distribution System 5 03 Efficiency 92 AFUE 80 AFUE 80 AFUE 80 AFUE 80 AFUE HERS Provider: CaICERTS inc. Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Description: Title 24 Analysis Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 11 of 14 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 01. _ .. _ py .. .. ; Efficiency Multi -speed 05 Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12 14 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 2 SplitAirCond 14.5 14.6 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 3 SplitAirCond 14 15 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 4 SplitAirCond 14.5 14.6. Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 5 SplitAirCond 14.4 16 Not Zonal Single Speed Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01. _ .. _ py .. .. ; - - - 03 _- 04 - 05 - 06 - - -- - - - -- - -- Name - - - Verified Airflow - t , AirftowTar s Target t Z �• -_ -- - - � Verified EER ,- f "? ✓� -- - - - - Verified SEER -- - - Verified Refrigerant Charge Cooling Component 1 -hers -cool %, Required. ,r ref j �, '`max 350.aRequired' Not Required Required Cooling Component 2 -hers -cool Required 350-�," Required Required Required Cooling Component 3 -hers -cool Required 350 - Required Required Required Cooling Component 4 -hers -cool Required 350 Required Required Required Cooling Component 5 -hers -cool Required 350 Required Required Required Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Description: Title 24 Analysis Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Input File Name: VELARDE - T24 040515.xml CF1R-PRF-01 Page 12 of 14 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2 -hers -dist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3 -hers -list Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4 -hers -dist Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02, 03 04 05 06 07 08 'Name Duct Leakage Verification. w Duct Leakage ^"* Target (%) Verified Duct r7_Lccation�-, ,' Verified Duct );, `=Design r Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required. ri .1i.0 ; i l `Not Required -Not Required S ^% r Not Required Not Required -- Air Distribution System 2 -hers -dist Required k HVAC Fan 4 -hers -fan .''Not Required - f; -Wt Required l ?. Not Required Not Required — Air Distribution System 3 -hers -dist Required ;E-6.0� Not Required Not Required) - Not Required Not Required — Air Distribution System 4 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required -- Air Distribution System 5 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required -- HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05,11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name:.VELARDE Calculation Date/Time: 15:54, Sun, Apr 05, 2015` Calculation Description: Title 24 Analysis _ Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 13 of 14 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 HVAC Fan 3 -hers -fan Required 0.58 HVAC Fan 4 -hers -fan Required 0.58 HVAC Fan 5 -hers -fan -Required 0.58 . IAQ (indoor Air Quality) FANS 01 02 03 04 05 06 - • Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt x166.42 0.25 Default • 0 Required n,, ,. c ERT. E. Registration Number: 215-N0088215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -02272015-710 Report Generated at: 2015-04-05 15:58:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: VELARDE Calculation Description: Title 24 Analysis Calculation Date/Time: 15:54, Sun, Apr 05, 2015 Input File Name: VELARDE - T24 040515.xml CF1 R -PRF -01 Page 14 of 14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Santiago Lopez-Ocampo Company: Signature Date: Santiago Lopez-Ocampo 2015-04-07 08:43:48 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 1018 NA City/State/Zip: Phone: La Quinta, CA 92247 760 485 8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. ' 3. •The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on,other applicable compliance documents, worksheets, calculations, plans and specifications submitted tothe enforcement ;agency fo[ approval with this.building permit application. Responsible Designer Name: _F 1 ``•._ Responsible Designer Signature:; Eduardo Escobar . Company: t rr-^ Date,Signed: 2:2 Escobar Design 2015-G5-11 1 : Address: License: 43-927 Pacific Ave. NA City/State/Zip: Phone: Indio, CA 92201 760-289-9221 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N0066215A-000000000-0000 Registration Date/Time: 2015-05-11 16:42:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-02272015-710 Report Generated at: 2015-04-05 15:58:18 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name MR. & MRS. GEORGE VELARDE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/5/2015 Project Address 53389 VIA BELLAGIO La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,642 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 4,642 Perim = 0' New Wall Wood Framed R 21 4,697 New Demising Wood Framed R19 2,938 New Door Opaque Door - no insulation 24 New Roof Wood Framed Attic R38 4,642 New FENESTRATION Total Area: 1.082 Glazing Percentage: 23.3 % New/Altered Average U -Factor: Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades 0.30 Status Right (NW) 84.0 0.260 0.21 none none Bug Screen New Right (NW) 51.0 0.270 0.19 none none Bug Screen New Rear (SW) 40.0 0.270 0.17 none none Bug Screen New Rear (SW) 32.0 0.270 0.10 4.0 none Bug Screen New Rear (SW) 40.0 0.270 0.17 4.0 none Bug Screen New Rear (SW) 18.0 0.290 0.11 none none Bug Screen New Rear (SW) 170.0 0.260 0.17 18.5 none Bug Screen New Rear (SW) 55.0 0.260 0.17 none none Bug Screen New Left (SE) 93.5 0.260 0.21 none none Bug Screen New Left (SE) 48.0 0.270 0.17 none none Bug Screen New Left (SE) 15.0 0.290 0.11 none none Bug Screen New Front (NE) 71.0 0.260 0.21 none none Bug Screen New Front (NE) 96.0 0.710 0.73 none none Bug Screen New Right (NW) 40.0 0.260 0.17 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 92% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.6 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System - Zone 1 (4 Ducted Ducted Attic 8.0 New HVAC System - Zone 2 (3 Ducted Ducted Attic 8.0 New HVAC System - Zone 3 (2 Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.5 b Ener Soft User Number: 5732 RunCode: 2015-04-05716:19:23 /D: LQ040515 Pae 17 of 27 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name MR. & MRS. GEORGE VELARDE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/5/2015 Project Address 53389 VIA BELLAGIO La Quinta California Energy Climate Zone CA Climate Zone V Total Cond. Floor Area 4,642 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION I Total Area: 1,082 Glazing Percentage: 23.3%1New/Altered Average U -Factor: Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades 0.30 Status Rear (SW 100.0 0.260 0.17 15.5 none Bug Screen New Left (SE) 36.0 0.270 0.19 none none Bug Screen New Right (NIA 48.0 0.270 0.17 none none Bug Screen New Right (NK9 15.0 0.290 0.11 none none Bug Screen New Left (S) 13.6 0.260 0.21 none none Bug Screen New Front (NE) 15.8 0.270 0.19 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.6 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System - Zone 4 (1 1 Ducted Ducted Attic 8.0 New HVAC System - Zone 5 (5 i Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ene Pro 6.5 by Ene Soft User Number: 5732 RunCode: 2015-0405716:19:23 /D: LQ040515 Pae 18 of 27 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance aporoach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of $10-111 a . §110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose till insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R- 19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8( . 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §110.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandato §150.00)2C: § 150.00)3: § 150.00)3A: §150.00)3B: § 150.0(n)1: §I50.0(n)2: §150.0(n)3: Measures Summa Pipe for cooling system lines shall be insulated as specified in systems or hot waters stems with pressure > 15 psiQ shall me 150.00)2A. Piping insulation for steam and hydronic heating the requirements in TABLE 120.3-A. Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or _painted with coating that is water retardant and provides shielding from solar radiation that degrades the material Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I or Class tI vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. Recirculating loops serving multiple dwelling units shall meetthe requirements of §110.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements ofCMC §601.0, §602.0,on Standards Metal and Flexible 3rd Edition. §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)]: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %< inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, 'mastics, sealants, and other re uirements s ecified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic §I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and rovides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of S 0.58 W/CFM as confirmed by field verification and diagnostic testin , in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. § 150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b) l: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §I50.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §I50.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral. to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)lE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen I ighting if they are not separately switched from kitchen Ii htin . §I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. §150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, §130.0, §130.2, § 130.4, §140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply ' with the applicable requirements in § 110.9, 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §I50.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §1 10.10(a) 1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §1 10.10 b through 110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. §I 10.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. §110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.1 Old): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §1 10.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. & MRS. GEORGE VELARDE System Name HVAC System - Zone 1 (4 On Mechanical) ENGINEERING CHECKS SYSTEM LOAD Number of Systems Heating System output per System Total Output (Btuh Output Btuh/s ft Cooling System Output per System Total Output Btuh Total Output (Tons) Total Output Btuh/s Tntal nutnut fsnft/Tn Air System CFM per S ste Airflow cfm Airflow cfm/sc Airflow cfm/Tc Outside Air %a Outside Air cfi Note: values above 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 80,000 80,000 112.4 1 1 0.0 ft 0.0 n 8,544,000.0 0 cfm 0 HVAC EQUIPMENT SELECTION 0 High Efficiency Fau/AC 0.00 0.0 67 OF 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK I 0.00 at ARI conditions I rCHROMETRICS (Airstream Temperatures at Time 112/78°F Date 4/5/2015 Floor Area 712 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 377 7,566 942 161 6,191 0 437 304 0 0 0 0 0 0 0 0 0 437 304 8,440. 942 6,800 1 80,0001 11 01 1 80,000 Aug 3 PM Jan 1 AM 26 OF 67 OF 105 OF Outside Air 0 cfm Heating Coil 104 OF ROOM 67 OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/63°F 55/54°F HE Outside Air ffll 0 cfm Cooling Coil 56 / 54 OF 49.2% ROOM In 76/ 63 °F No- - _ 4 - I I 75 / 62 OF EnergyPro 6.5 by EnergySoft User Number- 5732 RunCode: 2015-04-05716:19:23 ID: LQ040515 Page 23 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. & MRS. GEORGE VELARDE Date 4/5/2015 System Name HVAC System - Zone 2 (3 On Mechanical) Floor Area 992 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 452 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 9,481 1,313 186 7,269 Total Output Btuh 80,000 0 Output Btuh/s ft 80.6 547 357 Cooling System 01 0 Output per System 47,000 0 0 0 0 Total Output Btuh 47,000 0 547 10,575 1,313 11 0 Total Output (Tons) 3.9 357 Total Output Btuh/s ft 47.4 Total Output s ft/Ton 253.3 7,984 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 York H4TSO48S06 31,329 8,322 80,000 Airflow (cfm/s ft) 1.81 Airflow cfm/Ton 459.6 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,329 8,322 F7 Aug 3 PM 80,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 OF 105 OF 105 OF u � Heating Coil Supply Fan 1,800 cfm 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 75 / 62 OF 75/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 1,800 cfm 55 / 54 OF 47.0% ROOM 75 / 62 OF I EnergyPro 6.5 by EnergySoft User Number.- 5732 RunCode: 2015-04-05T16:19:23 /D: LQ040515 Page 24 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. & MRS. GEORGE VELARDE Date 4/5/2015 System Name HVAC System - Zone 3 (2 On Mechanical) Floor Area 1,102 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 984 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 20,310 1,458 343 13,391 Total Output Btuh 80,000 0 Output Btuh/s ft 72.6 1,172 658 Cooling System 0 0 Output per System 59,500 0 0 0 0 Total Output Btuh 59,500 0 1,458 0 Total Output Tons 5.0 1,172 658 Total Output Btuh/s ft 54.0 Total Output s ft/Ton 222.3 1 22,655 14,708 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 York H4TS060S06 42,154 8,138 80,000 Airflow (cfm/s ft) 1.63 Airflow cfm/Ton 363.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 42,154 8,138 Aug 3 PM 80,000 Jan 1 AM Outside Air ctm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 680F 680F 105 OF ' 10'5 OF i^ (nom Heating Coil Supply Fan 1,80+0 cfm ° 105 F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76 / 62 OF 76/62°F 55/54°F 55/54°F c e Cooling Coil Supply Fan 1,800 cfm ' 56 / 54 OF 47.0 % ROOM 75 / 62 °F EnergyPro 6.5 by EnergySoft User Number: 5732 RunCode: 2015-0405716:19:23 ID: LQ040515 Page 25 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. & MRS. GEORGE VELARDE Date 4/5/2015 System Name HVAC System - Zone 4 (1 On Mechanical) Floor Area 1,030 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 543 Return Vented Lighting Return Air Ducts Return Fan VentilF-tion 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 11,364 1,363 229 8,971 Total Output Btuh) 80,000 0 Output Btuh/s ft 77.7 656 441 Cooling System 01 0 Output per System 47,000 0 0 0 0 Total Output Btuh 47,000 0 1,363 0 Total Output Tons 3.9 656 441 Total Output Btuh/s ft 45.6 Total Output s ft/Ton 263.0 1 12,676 9,853 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 York H4TSO48S06 31,387 8,280 80,000 Airflow (cfm/s ft) 1.75 Airflow cfm/Ton 459.6 80,000 F Jan 1 AM Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 31,387 8,280 Aug 3P ml Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 OF 105 °F 105 OF I� Heating Coil Suppily Fan 1,800 cfm I 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Ti,-ne of Cooling Peak 112/78°F Outside Air 0 cfm 75/62°F 75/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 1,800 cfm i 55 154 OF 47.0% j ROOM j 75/62°F EnergyPro 6.5 by EnergySoft User Number. 5732 RunCode: 2015-04-C5T16:19:23 ID: LQ040515 Page 26 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. & MRS. GEORGE VELARDE Date 4/5/2015 System Name HVAC System - Zone 5 (5 On Mechanical) Floor Area 806 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Lads 442 Return Vented Lighting Return Air Cucts Returr Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 9,268 1,067 189 7,388 Total Output (Btuh) 80,000 0 Output Btuh/s ft 99.3 535 363 Cooling S stem 0 0 Output per System 36,000 0 0 0 0 Total Output Btuh 36,000 0 535 1 10,3387 1,067 0 Total Output (Tons) 3.0 363 Total Output Btuh/s ft 44.7 Total Output s ft/Ton 268.7 8,114 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 York H4TS036S06 ' 22,143 8,203 80,000 Airflow (cfm/s ft) 2.23 Airflow cfm/Ton 600.0 i Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 22,143 8,203 Aug 3P m 80,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 260F Outside Air 0 cfm 680F 680F 105 OF 105 OF Heating Coil SupFly Fan 1,800 cfm 105 o F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Ti'rne of Cooling Peak 112/78°F Outside Air 0 cfm 75/62°F75/62°F 75/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 1,800 cfm _ 55 154 OF 46.8% j ROOM I EnergyPro 6.5 by EnergySoft User Number. 5732 RunCode: 2015-04-r5T16:19:23 ID: LQ040515 Page 27 of 27