Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2015-0085 Revision 1 Title 24
x f BUILDING ENERGY ANALYSIS REPORT PROJECT: Tomei Residence Lot 48C Via, Mallorca La Quinta, CA 92253 Project Designer: . ' 1050- Rod Street Fallbrook, CA 92028 (760)72879691 Report,Prepared :by: Ron James Jr. CITY OF LA QUINTA P:O. -BOX 29382 BUILDING.& SAFETY DEPT. Santa Fe, NM 87507 APPROVED FOR CONSTR CTION -(760) 61.0-0787 DATE I LS B tl ®lonv" iN�W. . C2 26 Job Number: MVE RE R 01-2015 JUN 2 2015 ° Date: I U, VlI r " CITY OF LA OUIIyTA 6/1/20.15 COMMUIVIT1r DEVELOPIWEIy } T The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 6.5 by Ener Soft User Number. 5062 ID: -01-2015 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 - Page 1 of 12 GENERAL INFORMATION 01 Project Name Tomei Residence Building Complies with Computer Performance 02 Calculation Description Title 24 Analysis 02 This building incorporates features that require field testing and/or verificationby a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 Project Location Lot 48C Via Mallorca 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3c (710) 08 Climate Zone CZ15 .09 Software Version EnergyPro 6.5 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number.of Dwelling Units 1 14 .Total Cond. Floor Area (FT;) 6805 15 'Number of Zones 4 16 Slab Area (FTZ) 0 17 �v Number of Stories 2 18 Addition Cond. Floor Area N/A *1 Natural Gas Available Yes 20 Addition Slab Area (FTZ) N/A - A Glazing Percentage (%) 18.0% Aw COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verificationby a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown`�below ENERGY USE SUMMARY 04 05�®W 06 07 08 Energy Use (kTDV/ft2-yr) Staf lord Dsign Proposed Design Compliance Margin Percent Improvement • Space Heating 1.30 . 0.70 0.60 46.2% Space Cooling 41f 75.94 . 70.46 5.48 7.2% IAQ Ventilation Qw 0.64 0.64 0.00 0.0% Water Heating 3.77 2.36 1.41 37.4% Photovoltaic Offset '� --- 0.00 0.00 -- Compliance Energy Total `. 81.65 74.16 7.49 9.2% Registration Number: CA Building Energy Efficiency ,Stan4o antis 2013 Residential Compliance Registration Date/Time: Report Version - CF111-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 • CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R -PRF -01. ' Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 20159 Pa 2.of 12 Calculation Description: Title 24 Analysis �' `Input File Name: Tomei Residence - Main House.xml r. ' ENERGY DESIGN RATING ` ' ` r "'sr • 7e - w • -F This is the sum of the annual TDV energy consumption for energy use components includechin the performance compliance approach for the Standard Design Build irig. (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (t6,89 as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system.,., qr r ; . - Reference Energy U - ' `* Ener Desi n Ratin ",_ c Mar in Percent Im rovement Total Ener kTDV/f2- r'• 116.55 `�411w , ` �' "Y.� 109 06 ' ` 7:49 6.4% includes calculated Appliances and Miscellaneous Energy Use (AMEU)`" 4 r BUILDING - FEATURES INFORMATION'- ~ , . Aff • , 01 * ' 02 .-.' .. ; ' '03 04 05 06 07 . r. ' � of D 'Number welling -' - Number of Ventilation Number of Water, Project Name rT Conditioned Floor Area ft2) Units 'Number of Bedrooms -, Number of Zones 'Cooling Systems Heating Systems .Tomei Residence - 6805.x. 1: 3 S 4: .. 0 ,. z 2 ' ... � � tai ya I,� . .. .i , c r y a .e • - + . _ - Registration Number:t:� n Registration Date/Time. F HERS Provider:40 . CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-06-01 11:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015" Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 3 of 12 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling . Height Water Heating System 1 Water Heating System 2p Basement Conditioned HVAC1 2974 9 DHW Sys 1 First Floor,. Conditioned HVAC1 2867 9 DHW Sys 1 Second Floor Conditioned HVAC1 583 8 DHW Sys 1 2nd Flr. Casita O/ House' Conditioned Mr. Slim - 2nd Flr. Casit2 381 8 DHW Sys 3 j . CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CFI R -PRF -01 Page 4of12' OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Exterior Wall Basement R-21 Wall 270 Back 60 56 90 Exterior Wall 2 Basement R-21 Wall 180 Left 30 24 90 Roof Basement R-38 Roof Attic 336 Basement Wall - N Basement 8 CMU Wall 650 Basement Wall - S Basement 8 CMU Wall 650 Basement Wall - E Basement 8 CMU Wall b 610 Basement Wall - W Basement 8 CMU Wall g/ 570 Exterior Wall 1 - North First Floor R-21 Wall 0 Right 560 49 90 Exterior Wall 2 - East First Floor R-21 Wall 146 90 Front 165 9 90 Exterior Wall 3 - South First Floor R-21 Wall 180 Left 170 90 Exterior Wall 4 - East First Floor R-21 Wall 90 Front 300 262.2 90 Exterior Wall 5 -N-E First Floor R-21 W%. 0 Right 60 24 90 Exterior Wall 5 - North First Floor R-21 11 0 Right 90 13.5 90 Exterior Wall 6 - East First Floor R-21 V�yall 90 Front 130 13.5 90 Exterior Wall 7 - South First Floor *fV1 Wall 180 Left 160 19.1 90 Exterior Wall 8 - East First Floor WR -21 Wall 90 Front 60 24 90 Exterior Wall 9 - South First Floor R-21 Wall 180 Left 285 22.5 90 Exterior Wall 10 -West First Floor R-19 Wall 270 Back 650 344 90 Exterior Wall 11 - South First Floor `'� R-21 Wall 180 Left 130 48 90 Exterior Wall 12 - West First Floor R-21 Wall 270 Back 190 96 90 Roof 2 First Floor O` R-38 Roof Attic 1903 Exterior Wall - North Second Floor R-21 Wall 0 Right 390 3.1 90 Exterior Wall - West Second Floor ' 11 R-21 Wall 270 Back 160 48 90 Exterior Wall - South Second Flr,_ o�or, R-21 Wall 180 Left 390 40 90 Exterior Wall - East Secondmoor R-21 Wall 90 Front 160 44 90 Roof 3 Secojn)tFloor R-38 Roof Attic 583 Exterior Wall - North 2 2nd FI,rr jdl�ita O/ House R-21 Wall 0 Right 300 24 90 Exterior Wall - East 2 2nd irCasita O/ House R-21 Wall 90 Front 130 8 90 Exterior Wall -South 2 2 Ir. Casita 0/ House R-21 Wall 180 Left 300 3.1 90 Exterior Wall - West 2 Wnd Fir. Casita O/ House R-21 Wall 270 Back 130 48 90 *67 Registration Number: IT Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF. -01 Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Page 5 of 12 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml Roof 4 2nd Fir. Casita O/ House R-38 Roof Attic 381 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof , ,Attic Basement Attic RoofBasement Ventilated 0 0.1 0.85 Yes No Attic First Floor Attic RoofFirst Floor Ventilated 3 0.1 0.85 Yes No Attic Second floor Attic RoofSecond Floor Ventilated 3 0.1 0.85 Yes No Attic 2nd Fir. Casita 0/ House Attic Roof2nd Fir. Casita O/ House Ventilated 3 0.1 0.85 Yes No CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 6 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (W) U -factor SHGC Exterior Shading 27 - Window 2 Window Exterior Wall (Back -270) -- -- 1 28.0 0.32 0.29 Insect Screen (default) 28 - Window 2 Window Exterior Wall (Back -270) ---- - - 1 28.0 0.32 0.29 Insect Screen (default) 29 - Fr. Dr. 1 Window Exterior Wall 2 (Left -180) ---- -- - 1 24.0 0.32 0.29 Insect Screen (default) 30 - Window 10 Window Exterior Wall 1 - North (Right -0) ---- ---- 1 4.5 0.32 0.29 Insect Screen (default) 31 - Window 10 Window Exterior Wall 1 - North (Right -0) --- ---- 1 4.5 0.32 0.29 Insect Screen (default) 32 - Window 11 Window Exterior Wall 1 - North (Right -0) ----� ---- 1 9.0 0.32 0.29 Insect Screen (default) 33 - Window 11 Window Exterior Wall 1 - North (Right -0) -: `4 ---- OVA 1 9.0 0.32 0.29 Insect Screen (default) 34 - Window 11 Window Exterior Wall 1 - North (Right -0)- -- 1 9.0 0.32 0.29 Insect Screen (default) 35 - Window 11 Window Exterior Wall 1 - North (Right -0) `��--- -- 1 9.0 0.32 0.29 Insect Screen (default) 36 - Window 4 Window Exterior Wall 1 - North (Right -0) '�` ---- --- 1 4.0 0.32 0.29 Insect Screen (default) 37 - Window 10 Window Exterior Wall 2 - East (Front -90) `� ---- ---- 1 4.5 0.32 0.29 Insect Screen (default) 38 - Window 10 Window Exterior Wall 2 - East (Front -90) --- ---- 1 4.5 0.32 0.29 Insect Screen (default) 39 - Entry Dr. 1 Window Exterior Wall 4 - East (Front -90) ---- ---- 1 46.2 0.55 0.67 Insect Screen (default) 40 - PD. 2 Window Exterior Wall 4 - East (Front-90)� 18.0 12.0 1 216.0 0.32 0.29 Insect Screen (default) 41 - Fr. Dr. 6 Window. Exterior Wall 5 -N-E (Right& ---- ---- 1 24.0 0.32 0.29 Insect Screen (default) 42 - Window 5 Window Exterior Wall 5 - North (Right 0) -- --- 1 13.5 0.32 0.29 Insect Screen (default) 43 - Window 5 Window Exterior Wall 6 - East&`alit-90) ---- ---- 1 13.5 0.32 0.29 Insect Screen (default) 44 - Window 2 Window Exterior Wall 7 - SdUiRf(Left-180) -- -- 1 3.1 0.32 0.29 Insect Screen (default) 45 - Window 6 Window Exterior Wall 7 -S uih (Left -180) ---- ---- 1 16.0 0.32 0.29 Insect Screen (default) 46 - Fr. Dr. 6 Window Exterior Wall - East (Front -90) ---- --- 1 24.0 0.32 0.29 Insect Screen (default) 47 - Window 7 Window Exterior Vlfall)l9 - South (Left -180) --- -- - 1 22.5 0.32 0.29 Insect Screen (default) 48 - Window 7 Window Exterior�`W,all 10 -West (Back -270) ---- ---- 1 22.5 0.32 0.29 Insect Screen (default) 49 - SI. GI. Dr. 3 Window Exterio Mail 10 -West (Back -270) ---- ---- 1 48.0 0.32 0.29 Insect Screen (default) 50 - P.D. 2 Window Exp nor Wall 10 - West (Back -270) 18.0 12.0 1 216.0 0.32 0.29 Insect Screen (default) 51 - Window 8 Window Gx[erior Wall 10 -West (Back -270) --- --- 1 57.5 0.32 0.29 Insect Screen (default) 52 - P.D. 3 Window ®Exterior Wall 11 -South (Left -180) ---- --- 1 48.0 0.32 0.29 Insect Screen (default) 53 - P.D. 4 Windows Exterior Wall 12 - West (Back -270) ---- ---- 1 96.0 0.32 0.29 Insect Screen (default) 54 - Window 4 Window Exterior Wall - North (Right -0) --- -- 1 3.1 0.32 0.29 Insect Screen (default) 55 - Fr.' Drs. 1 Window Exterior Wall - West (Back -270) --- -- 1 48.0 0.32 0.29 Insect Screen (default) ®Igo Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE: COMPLIANCE METHOD Project Name: Tomei Residence. Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 7of12' 56 - Window 1 Window Exterior Wall- South (Left -180) -- - -- - 1 8.0 0.32 0.29 Insect Screen (default) 57 - Window 1 Window Exterior Wall - South (Left -180) ---- --- 1 8.0 0.32 0.29 Insect Screen (default) 58 - Window 1 Window .. Exterior Wall - South (Left -180) ---- ---- . 1 8.0 0.32' 0.29 Insect Screen (default) 59 - Window 3 Window Exterior Wall -South (Left -180) --- - 1 16.0 0.32 0.29 Insect Screen (default) 60 - Window 2 Window Exterior Wall - East (Front -90) -- --- 1 10.0 0.32 0.29 Insect Screen'(default) 61 - Window 2 Window Exterior Wall - East (Front -90) -- ---- 1 10.0 0.32 0.29 Insect Screen (default) 62 - Fr. Dr. 3 Window Exterior Wall -`East (Front -90) --- --- 1 24.0 0.32 0.29 Insect Screen (default) 63 - Window 1 Window Exterior Wall - North 2 (Right -0) --- --- 1 8.0 0.32 0.29 Insect Screen .(default) 64 - Window 1 Window Exterior Wall- North 2 (Right -0) ---- ---- 1 8.0 0.32 0.29 Insect Screen (default) 65 - Window 7 Window., Exterior Wall.- North 2 (Right -l)) ---��` --- 1 8.0 0.32 .0.29 Insect Screen (default) 66 - Window 1 Window Exterior Wall - East 2 (Front -90) ---- 1 8.0' 0.32 0.29 Insect Screen (default) 67 - Window 4 Window Exterior Wall - South 2, (Left -180) Gam'-- -- 1' 3.1 0:32 0.29 Insect Screen (default) 68 - Fr.Drs. 1 Window' Exterior Wall -West 2 (Back -270) `'% ---- ` ---- 1 48.0 0.32 0.29 Insect Screen (default). OVERHANGS AND FINS 01 02 03 04 05' 08, 07 08 09 .10. 11 12 13 14 Overhang- Left Fin Right Fin Window Depth Dist Up Left Extent Right Ekf$f t Flap Ht. Depth Top Up-. DistL Bot Up- Depth Top Up . Dist R Bot Up 40 - PD. 2 .8- 0.1 8 Sr8 0 0 0 0 0 0 0 0AN 0 50 - P.D. 2 12 0.1 12► 12 0 0 0 0 0 0 0 0 0 Registration Number:�� Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 8 of 12 ` OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity/ Frame: no insul. / 2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Roofing: 25 PSF (Very Heavy Ballast or Attic RoofBasement Attic Roofs Wood Framed Ceiling in. O.C. none 0.571 Pavers) " Inside Finish: Gypsum Board • Cavity /Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking Inside Finish: Gypsum Board Qj Insulation/Furring: R-19 / 3.5in. wd 8 CMU Wall Underground Walls (null) 0.062 Mass Layer: "8 in. NW CMU Solid Grout • Inside Finish: Gypsum Board. Ceilings (below Cavity/ Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 'h10.C.' R $8 0.025 Over Floor Joists: R-28.9 insul. • Cavity / Frame: no insul. / 2x4 Top Chrd p�4 Roof Deck: Wood Siding/sheathing/decking 2x4 Top Ch6r?b�of Roof Truss.@ 24 Roofing: 25 PSF (Very Heavy Ballast or Attic RoofFirsf Floor Attic Roofs Wood Framed Ceiling AWAR in. O.C.. none 0.571 Pavers) v®` Inside Finish: Gypsum Board Cavity / Frame.. R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior. Walls Wood Framed Wall 4ff 2x6 @ 16 in. O.C. R'l9 0.069 Siding/sheathing/decking Floor Surface: Carpeted .Floor Deck. Wood Siding/sheathing/decking �® • Cavity/ Frame: no insul. / 2x12 R-0 Floor Crawlspace Interior Floors Wood Framed E3r 2x12 @ 16 in. O.C. none 0.196 Ceiling Below Finish: Gypsum Board ®Cavity/ Frame: no insul. / 2x4 Top Chrd " • Roof Deck: Wood Siding/sheathing/decking � 2x4 Top Chord of Roof Truss @ 24 Roofing. 25 PSF (Very Heavy Ballast or Attic RoofSecond Floor Attic Roofs Wood F an -)ed Ceiling in. O.C: none 0.571 Pavers) v Cavity / Frame: no insul."/ 2x4" Top Chrd • Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd Fir. Casita O/ 2x4 Top Chord of Roof Truss @ 24 Roofing: 25 PSF (Very Heavy Ballast or House Attic Roofs ood Framed Ceiling in. O.C. none 0.571 Pavers) 0 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x12 R-0 Floor No Crawlspace Interior Fl�fs Wood Framed Floor 2x12 @ 16 in..O.C. none 0.196 Ceiling Below Finish: Gypsum Board v Registration Number: Registration Date/Time: CA Building Energy Efficiency Stan d`a'rds - 2013 Residential Compliance Report Version - CF111-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 9,of12 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04, 01 02 03 04. 05 ' 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines :'DHW Heater 1 1 _ .0% DHW Sys 3 - 1/1 DHW Pipe Insulation, All Lines .`� DHW Heater 3 1 .0% WATER HEATERS 01 02 03 04, 05 06 07 08 Pipe Insulation VAEr ® Parallel Piping. Compact Distribution Point -of Use Energy Central DHW = Distribution Tank Exterior 'Insulation Standby Loss -� Distribution Name Cooling Component 1:Heating Component 1:Air Tanlume factor or DHW Sys 3 - 1/1 --- --- Name Heater Element Type Tank Type (gal) Efficiency Input Rating R -value (Fraction) DHW Heater 1 Natural Gas Small Instantaneous' �� 0 0.84 185000-Btu/hr 0 0 DHW Heater 3 Natural Gas Small Instantaneous 0 0.84 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 0607 Name Pipe Insulation VAEr ® Parallel Piping. Compact Distribution Point -of Use Recirculation Control. Central DHW = Distribution DHW Sys 1 - 1/1 -- -� Distribution Name Cooling Component 1:Heating Component 1:Air -Skier Heating and Cooling Heating Component 1 DHW Sys 3 - 1/1 --- --- -- �� System & 11 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air -Skier Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Distribution System 1:HVAC Fan 1:1 �� System Registration Number: 4�i, Registration Date/Time: CA Building Energy Efficiency Stands 2013 Residential Compliance Report Version - CF111-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 10 of 12 SPACE CONDITIONING SYSTEMS " 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name :Heat Pump System 2:<:2 , Heat Pump Heating and Cooling System _ Heat Pump System 2 Heat Pump System 2 None None HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFllrnaCe - Fuel -fired zAtral furnace 80 AFUE HVAC -HEAT PUMPS 01 02 03 04 , 05 . 06 07 08 09 10 �/,�Q VerifieU AirfiOW Efficiency Heating Cooling Zonally Multispeed. HERS ♦ EER SEER Zonally Controlled ' HERS Verification Cooling Component 1 SplitAirCond `� . 13 Name Type , HSPF/COP Cap&7 Cap 17 SEER EER Controlled Compressor Verification F Heat Pump System 2 DuctlessHeatPump 8.5 Q000• 16000 13 11.3 No .,.No Heat Pump System, Cooling Component . 1 -hers -cool 2 -hers -cool HVAC - COOLING UNIT TYPES vNO," 01 02 04 05 06 07 ' Name �/,�Q VerifieU AirfiOW Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type ♦ EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond `� . 13 16 Not Zonal Single Speed Cooling Component 1 -hers -cool DuctlessHeatPump , 11.3 13 Not Zonal Single Speed Cooling Component . 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02, 03 04 05 06 , Name �/,�Q VerifieU AirfiOW Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-coolRequired 350 Not Required Required Not Required Heat Pump System 2 -hers -cool r Required 350 Not Required Not Required Not Required Registration Number: Registration Date/Time: CA Building Energy Efficiency Stands - 2013 Residential Compliance Report Version - CF1R-02272015-710 HERS Provider: Report Generated at: 2015-06-01 11:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project. Name: Tomei _Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Page 11 of 12 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence -Main House.xml HVAC - DISTRIBUTION SYSTEMS 01 02 03 •04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Sealed and tested 8 Attic None Air Distribution System 1 -hers -dist Not Required Not Required --- None HVAC DISTRIBUTION -HERS VERIFICATION ' 01 02 03 04 05 06 07, 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location ,Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required _ 6.0 Required& Not Required Not Required Not Required --- HVAC - FAN SYSTEMS 01 02 �/ - 03 04 Name Type v Fan Power(Watts/CFM) HER, Verification HVAC Fan 1 Single Speed PSC FurnacgFan 0.58 HVAC fan 1 -hers -fan HVAC FAN SYSTEMS'- HERS VERIFICATION®r, , 01' 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan0 Required 0.58 *%�W IAO (Indoor Air Quality) FANS 01 02 � 03 04 • 05. 06 Dwelling Unit IAQ CFM IAQ Watts/CFM :. IAQ Fan Type IAQ Recovery Effectiveness(%) ' HERS Verification SFam IAQVentRpt 98.05 0.25 Default 0 •Required • "i0 Registration Number:®, Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 HERS Provider: Report Generated at: 2015-06-0111:55:14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Tomei Residence Calculation Date/Time: 12:48, Mon, Jun 01, 2015 Calculation Description: Title 24 Analysis Input File Name: Tomei Residence - Main House.xml CF1 R -PRF -01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Company: Signature Date: Ron James Jr. 6/1/2015 Address: CEA/HERS Certification.ldentification (If applicable): P.O. Box 29382 City/Stateip: -Fanta; Fe, NM 87507, Phone: O 610-0787 RESPONSIBLE PERSON'S DECLARATION STATEMENT. - I certify the following under penalty of perjury, under the laws of the State of California: e 1.. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for h building design identified on this Certificate of, Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate yof-mpliance conform to the requirements of Title 4, Part Land Part'6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Co41`ance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and 'specifications submitted to the enforcement agenCAW approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Paul T. Olson Company: ♦♦`� Date Signed: Address: �4V License: . 1050 Rod Street- �, City/State/Zip: Phone: Fallbrook, CA 92028 (760) 728-9691 O Registration Number:® Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-02272015-710 HERS Provider: Report Generated at: 2015-06-01 11:55:14 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Tomei Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/1/2015 Project Address Lot 48C Via Mallorca La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,805 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FloorBG Unheated Slab-on-Grade - no insulation 2,974 New Wall Wood Framed R 21 3,471 New Wa11BG Hollow Unit Masonry - no insulation 2,480 Rigid=R-19.0 Depth = 120.000" New Roof Wood Framed Attic R38 3,203 New Demising Wood Framed Rafter - no insulation 2,867 New Wall Wood Framed R 19 306 New Demising Wood Framed w/Crawl Space - no insulation 3,450 New Demising Wood Framed R-13 381 New FENESTRATION I Total Area: 1,223 Glazing Percentage: 18.0 New/Altered Average U-Factor: Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades 0.33 Status Rear (W) 376.0 0.320 0.29 none none Bug Screen New Left (S) 156.7 0.320 0.29 none none Bug Screen New Right (N) 113.6 0.320 0.29 none none Bug Screen New Front (E) 98.5 0.320 0.29 none none Bug Screen New Front (E) 46.2 0.550 0.67 none none Bug Screen New Front (E) 216.0 0.320 0.29 8.0 none Bug Screen New Rear (lM 216.0 0.320 0.29 12.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Split Heat Pump 8.50 HSPF Split Heat Pump 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC Ducted Ducted Conditioned 8.0 New Mr. Slim - 2nd Flr. Casita Ductless /--with Fan Ductless We n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.84 All Pipes Ins New 1 Small Instantaneous Gas 0 0.84 All Pipes Ins New Ener Pro 6.5 by Ener Soft User Number.- 5062 RunCode: 2015-06-01T14:18:25 ID: 01-2015 Page 14 of 15 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Tomei Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/1/2015 Project Address Lot 48C Via Mallorca La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,805 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Demising Wood Framed w/o Crawl Space - no insulation 381 New FENESTRATION Total Area: 1,223 Glazing Percentage: 18.0 New/Altered Average U -Factor: Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades 0.33 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.5 by Ener Soft User Number.• 5062 RunCode: 2015-06-01714:18:25 ID: 01-2015 Pae 15 of 15