BRES2015-0110 Revision 2 Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Smith Residence
80-770 Via Montecito
La Quinta , CA 92253
Project Designer:
McFadden Architects
75-145 St. Charles Place
Palm Desert, CA 92211
760-346-8014
CITY OF LA QUID IA -
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 16 kb BY
Report Prepared by:
FF LE ,,
Micah Combs
C.M. Energy Consulting
75-145 St. Charles Place, Suite 4
Palm Desert, CA 92211
760-574-9267
'� Ie 101
1
Job Number:
1432.01 RECEIvEl)
Date: DEC'2 2 2015
11/4/2015 C17Y of LA DUINTA
COMMUNI7Y DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.con.
cclr*v) ti's'
I' TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R -PRF -01-E Certificate of Compliance
Form RMS -1 Residential Measures Summary
Form MF -1 R Mandatory Measures Summary
EnergyPro 6.7 by EnergySoft Job Number. ID: 1432.01 User Number. 1086
1
2
3
16
18
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: SmithReviseci.xml
CF1 R -PRF -0J
Page 1 of 13
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Smith Residence
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ftz-yr)
03
Project Location 80-770 Via Montecito
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 3999
15
Number of Zones 4
16
Slab Area (W) 3999
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) N/A
21
Glazing Percentage (%) 38.6%
f ,N
COMPLIANCE RESULTS
01 Building Complies with Computer Performance' 1-1 1 s �.---.r IIF
�' �� as �: �� y,,
02 This building incorporates futures that reyu re Feld testing and/orwerificabon *by a certifed HERS rdterF under the supervision of a CEC-approved HERS provider.
03 This building Incorporates one or more Special Features shown below
..�v V- V 11 la.. aF"lr
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: Ca10ERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 11:57:23
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftz-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space I Wating
8,01
6.117
-3.06
-101.7%
Space Cooling
109.53
107.99
1.54
1.4%
IAQ Ventilation
1.54
1.54
0.00
0.0%
Water Heating
6.42
3.68
2.74
42.7%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
120.50
119.28
1.22
1.0%
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: Ca10ERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015 Page 2 of 18
Calculation Description: Title 24 Analysis Input File Name: SmithRevised.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
—None—
ENERGY
None—
ENERGY DESIGN RATING r~—� i Z ' •� { ;' i ,4
This is the sum of the annual T11V energy consumption,for energy usecomponehfs included in the peifoririance compliance approach for the --Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24; Part,6 (such as domestictpliances'and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. 11I a 4 u— " .;7r 4— ti V I &.of — L A
Reference Energy UseEnergy Design Rating Margin Percent improvement
Total Energy (kTDV/f2-yr)* 159.55 1158.33 1 1.22 0.8%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Smith Residence
3999
1
12
4
0
2
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: SmithRevised.xml
CFI R -PRF -01
Page 3 of 13
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
Zone #11
918
9
DHW Sys 1
Window & Door Area (ft2)
Living
Conditioned
Zone #22
1945
12
DHW Sys 3
100
Zone #3
Conditioned
Zone #33
682
9
DHW Sys 3
Left
Zone #4
Conditioned
Zone #44
454
9
DHW Sys 3
OPAQUE SURFACES
01
02
03
04
06
06
07
08
Name
! 'Zone
Construction
Azimuth
Orientation Gross Area (ftz)
Window & Door Area (ft2)
Tilt (deg)
Northeast Wall
FMaster Suite
R-21 Wall
45
Right
100
90
Southwest Wall
Master. Suite
R-21 Wall
225
Left
221
24
90
Northwest Wall
Master Suite
R-21 Wall
373
176
90
Roof
s ' Master.Suitet'
. R 38 F:oofAtt,.
918
Northeast Wall 2
1 ;,f fL vi*��
I i �kR-21 �INalf I x
E_31Baric
IRight:t
700
335.018
90
Southeast Wall
1 Living
'Front
x..� - >�• ..
582
184.989
90
Southwest Wall 2
' Livings
f 1;» CA R=21 Wall'— 0-1
`+ 0 225 I
L—* Left- tr -
54
27.9975
90
Northwest Wall 2
Living
R-21 Wall
315
Baric
635
502.014
90
Roof 2
Living
R-38 Roof Attic
1945
Southwest Wall 3
Zone #3
R-21 Wall
225
Left
136
90
Northwest Wall 3
Zone #3
R-21 Wall
315
Back
375
176
90
Roof 3
Northeast Wall 3
Zone #3
Zone #4
R-30 Roof Attic
1R-21 Wall
45
Right
682
700
90
Southeast Wall 2
Zone #4
R-21 Wall
135
Front
582
28.392
90
Southwest Wall 4
Zone #4
R-21 Wall
225
Left
54
90
Northwest Wall 4
Zone #4
R-21 Wall
315
Badc
635
88
90
Roof 4
Zone #4
R-30 Roof Attic
454
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CeICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: SmithRevised.xml
CFI R -PRF -01
Page 4 of 13
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Ventilated
3.5
0.1
0.85
Yes
No
Attic Living
Attic RoofLiving
Ventilated
3.5
0.1
0.85
Yes
No
Attic Zone #3
Attic RoofZone #3
Ventilated
0
0.1
0.85
No
No
Attic Zone #4
Attic RoofZone #4
Ventilated
0
0.1
0.85
No
No
J -
1`RR T- SC I 23� i E -
HERS PRIDH
Registration Number: 215-N6403645A-0DDD0oo0o-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: SmithRevised.xml
CF1 R -PRF -01
Page 5of13
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft) Height (ft)
Multipli
er
Area
(ft)
U -factor
SHGC
Exterior Shading
Fixed - G
Window
Southwest Wall (Left -225)
3.0
8.0
1
24.0
0.26
0.17
Insect Screen (default)
SlidingDr- 10
Window
Northwest Wall (Back -315)
12.0
9.0
1
108.0
0.29
0.17
Insect Screen (default)
FrDr - 9
Window
Northwest Wall (Back -315)
2.5
8.0
1
20.0
0.28
0.17
Insect Screen (default)
SlidingDr - 8
Window
Northwest Wall (Back -315)
6.0
8.0
1
48.0
0.29
0.17
Insect Screen (default)
SlidingDr - 12
Window
Northeast Wall 2 (Right45)
7.0
9.0
1
63.0
0.29
0.17
Insect Screen (default)
SlidingDr - 16
Window
Northeast Wall 2 (Right -45)
6.0
8.0
1
48.0
0.29
0.17
Insect Screen (default)
SlidingDr - 14
Window
Northeast Wall 2 (Right -45)
7.0
9.0
1
63.0
0.29
0.17
Insect Screen (default)
SlidingDr - 17
Window
Northeast Wall 2 (Right -45)
6.0
8.0
1
48.0
0.29
0.17
Insect Screen (default)
Fixed - Q
Window
Northeast Wall 2 (Right45)
3.3
2.1
1.026
7.0
0.26
0.17
Insect Screen (default)
Fixed - O
Window
; ` Northeast Wall 2 (Right -45)
3.1
2.1
1.075
7.0
0.26
0.17
Insect Screen (default)
Fixed - O 2
Window.
- Northeast Wall 2 (Right -45)
3.1
2.1
1.075
7.0
0.26
0.17
Insect Screen (default)
Fixed - U
Window
' �,ti lNortheastWall 2 (Rights) f -5.68.0
1.027
46.0
0.28
0.17
Insect Screen (default)
Fixed - V
Window
/j Northeast Wall 2 (Right 45)
5.6
1ti 8.0
11:027 ;46.0
0.28
0.17
Insect Screen (default)
Fixed - H
Window
` -' (� nt°135j �� 2 0
Southeast -Wail Fro
}t .O
1 L--1,60
0.26
0.17
Insect Screen (default)
FrDr - 24
Window
Southeast,Wall Front -135
+� .y 3:0
8:0
1 _
24.0
0.28
0.17
Insect Screen (default)
Fixed - B
Window
Southeast Wall (Front -135)
3.0
8.0
1
24.0
0.29
0.19
Insect Screen (default)
Fixed - A
Window
Southeast Wall (Front -135)
3.0
8.0
1
24.0
0.29
0.19
Insect Screen (default)
Fixed - R
Window
Southeast Wall (Front -135)
3.0
4.2
0.992
12.5
0.29
0.19
Insect Screen (default)
Fixed - S
Window
Southeast Wall (Front -135)
3.0
4.2
0.992
12.5
0.29
0.19
Insect Screen (default)
Fixed - T
Window
Southeast Wall (Front -135)
6.0
4.2
0.952
24.0
0.29
0.19
Insect Screen (default)
1'-1111y DOU, - I
Wirlduvv
Cauth000t Wall (Front 136)
-
1
48,0
1,04
0.63
Insect Screen (default)
Fixed - F
Window
Southwest Wall 2 (Left -225)
3.0
2.5
3.733
28.0
0.26
0.17
Insect Screen (default)
SlidingDr - 15
Window
Northwest Wall 2 (Back -315)
17.6
10.0
1.006
177.1
0.29
0.17
Insect Screen (default)
SlidingDr - 13
Window
Northwest Wall 2 (Back -315)
11.0
9.0
1
99.0
0.29
0.17
Insect Screen (default)
SlidingPcd - 11
Window
Northwest Wall 2 (Back -315)
16.6
9.0
0.997
149.0
0.30
0.18
Insect Screen (default)
FrDr - 6
Window
Northwest Wall 2 (Back -315)
3.0
8.0
1
24.0
0.28
0.17
Insect Screen (default)
Fixed - N
Window
Northwest Wall 2 (Back -315)
3.0
2.6
1.026
8.0
0.26
0.17
Insect Screen (default)
Fixed - N 2
Window
Northwest Wall 2 (Back -315)
3.0
2.6
1.026
8.0
0.26
0.17
Insect Screen (default)
Fixed - N 3
Window
Northwest Wall 2 (Back -315)
3.0
2.6
1.026
1 8.0
0.26 1
0.17
Insect Screen (default)
Registration Number: 215-N6403645A-000000000-0000 . Registration Datefrime: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-0411:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: SmithRevised.xml
CFI R -PRF -01
Page 6 of 13
Fixed - N 4
Window
Northwest Wall 2 (Back -315)
3.0
2.6
1.026
8.0
0.26
0.17
Insect Screen (default)
Fixed - P
Window
Northwest Wall 2 (Back -315)
3.1
2.1
1.075
7.0
0.26
0.17
Insect Screen (default)
Fixed - P 2
Window
Northwest Wall 2 (Back -315)
3.1
2.1
1.075
7.0
0.26
0.17
Insect Screen (default)
Fixed - P 3
Window
Northwest Wall 2 (Back -315)
3.1
2.1
1.075
7.0
0.26
0.17
Insect Screen (default)
SlidingDr - 23
Window
Northwest Wall 3 (Back -315)
8.0
8.0
1
64.0
0.29
0.17
Insect Screen (default)
SlidingDr - 22
Window
Northwest Wall 3 (Back -315)
8.0
8.0
1
64.0
0.29
0.17
Insect Screen (default)
Fixed - L
Window
Northwest Wall 3 (Back -315)
3.0
8.0
1
24.0
0.26
0.17
Insect Screen (default)
Fixed - M
Window
Northwest Wall 3 (Back -315)
3.0
8.0
1
24.0
0.26
0.17
Insect Screen (default)
Fixed - I
Window
Southeast Wall 2 (Front -135)
2.8
5.0
1.014
14.2
0.26
0.17
Insect Screen (default)
Fixed - J
Window
Southeast Wall 2 (Front -135)
2.8
5.0
1.014
14.2
0.26
0.17
Insect Screen (default)
FrDr - 20
Window
Northwest Wall 4 (Back -315)
3.0
8.0
1
24.0
0.28
0.17
Insect Screen (default)
SlidingDr - 21
Window
Northwest Wall 4 (Back -315)
8.0
8.0
1
64.0
0.29
0.17
Insect Screen (default)
H E RS P R O V17
D I F`
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: SmithRevised.xml
J
CFI R -PRF -01
Page 7 of 13
OVERHANGS AND FINS
01
02 03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Fixed - G
1 0.1
1
1
0
1
0
0.1
0
1
0
0.1
0
SlidingDr - 10
9 1
3.5
3.5
0
0
0
0
0
11
0
0.1
0
FrDr - 9
0 1 0
0
0
0 1
8.5
0
0.1
0
0
0
0
0
SlidingDr - 8
1 0.1
1
1
0
1
0
0.1
0
1
0
0.1
0
SlidingDr- 12
13 4
13
13
0
10
0
0.1
0
0
0
0
0
SlidingDr - 16
1 0.1
1
1
0
1
0
0.1
0
1
0
0.1
0
SlidingDr - 14
0 �^ 0
0
0
0
0
0
0
0
19
0
0.1
0
SlidingDr - 17
121' 1
3
3
0
0
0
0
0
0
0
0
0
Fixed - Q
11 j i, 0.1
11
11
0
0
0
0
0
0
0
0
0
Fixed - O
13' 0.1 - 13
13
0
0
0
0
0
0
0
0
0
Fixed -O2
13 ,0.1"
13
13..E ,w r..40y,..,,�
0 �. Y
0
0
0
0
0
0
0
Fixed - U
,'1 �� -/ 0.1
1
i 1
L y 0
1 �.`
0 0 1-
0
1
0
0.1
0
Fixed - V
! f1. "V9.1
i1
�1a„, t
;'' .^,� S
i
d 1 #�- .
17 0 � � � ,
� 0:1 � �
0
1
0
0.1
0
Fixed - H
;! 1 17:1
1
1
•q,
eo. vi
`d# 0�-N
r' -z0 -!-J
0
1
0
0.1
0
FrDr - 24
2 0:1
`2 -w-
2 11
" 0
` 2` .5 w
0'
"` 0.1
0
2.5
0
0.1
0
Fixed - B
0 0
0
0
0
1
0
0.1
0
1
0
0.1
0
Fixed - A
0 0
0
0
0
1
0
0.1
0
1
0
0.1
0
Fixed - R
4 0.1
4
4
0
1
0
0.1
0
1
0
0.1
0
Fixed - S
4 0.1
4
4
0
1
0
0.1
0
1
0
0.1
0
Fixed - T
4 0.1
4
4
0
0
0
0
0
0
0
0
0
Fixed - F
0 0
0
0
0
9
0
0.1
0
0
0
0
0
SlidingDr - 15
0 0
0
0
0
0
0
0
0
7
0
0.1
0
SlidingDr - 13
9 4
9
9
0
0
0
0
0
7
0
0.1
0
SlidingPcld - 11
11 4
11
11
0
0
0
0
0 1
11
0
0.1
0
FrDr - 6
0 0
0
0
0
10
0
0.1
0
0
0
0
0
Fixed - N
5 0.1
5
5
0
4
0
0.1
0
4
0
0.1
0
Fixed - N 2
5 0.1
5
5
0
4
0
0.1
0
4
0
0.1
0
Fixed - N 3
5 1 0.1
5
5
0
4
0
0.1
0
4
0
0.1
0
Registration Number: 215-N6403645A-000000000.0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Input File Name: SmithRevised.xml
CFI R -PRF -01
Page 8 of 13
Fixed -N4
5
0.1
5
5
0
4
0
0.1
0
4
0
0.1
0
Fixed - P
0
0
0
0
0
0
0
0
0
0
0
0
0
Fixed - P 2
0
0
0
0
0
0
0
0
0
0
0
0
0
Fixed - P 3
0
0
0
0
0
0
0
0
0
0
0
0
0
SlidingDr - 23
7.5
1
7.5
7.5
0
30
0
0.1
0
1
0
0.1
0
SlidingDr - 22
7.5
1
7.5
7.5
0
1
0
0.1
0
1
0
0.1
0
Fixed - L
7.5
1
7.5
7.5
0
1
0
0.1
0
1
0
0.1
0
Fixed - M
7.5
1
7.5
7.5
0
1
0
0.1
0
1
0
0.1
0
Fixed -1
1
0.1
1
1
0
1
0
0.1
0
1
0
0.1
0
Fixed - J
1
0.1
1
1
0
1
0
0.1
0
1
0
0.1
0
FrDr - 20
2
0.1
2
2
0
2.5
0
0.1
0
2.5
0
0.1
0
SlidingDr - 21
1
0.1
1
1
0
1
0
0.1
0
1
0
0.1
0
OPAQUE SURFACE CONSTRUCTIONS % `!' 1,
01
4. 02 J
- 03
04
05
06
07
r^>-.
ming
Total Cavity
Winter Design
Construction Name
Surfac® TjrPe
(Construction Type
}Fr
R -value f
t ,U -value
Assembly Layers
a
Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top:Chord of -Roof Truss@ 24"
/ i
?
•Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Suite
Attic Roofs
Wood FramedCeiling
m. O:C.
�r none-
I0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
• Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R41 Wall
Foderior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
-
0.066
Siding/sheathing/decking
• Cavity i' l7mme: no incul. / 2xa Thp Chrd
f
2x4 Top Chord of Roof Truss @ 24
. Roof Dec/r: Wood Siding/sheathing/decking
Attic RoofLiving
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
- Roof Deck: Wood Siding/sheathing/decking
Attic RoofZone #3
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
• Over Floor Joists: R-20.9 insul.
• Cavity/ Frame: no insul. / 2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofZone #4
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: SmithRevised.xmi
CF1 R -PRF -01_
Page 9 of 13
SLAB FLOORS
01 02 03 _ 04 Ob 08 07 nR
R1r� P►R .1+� Tom•: N1'R
+xr4. !! MWhF.i.
y:w•
01
01
02
03
04
06
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Exposed Slab
Master Suite
827
59.3
None
0
No
Covered Slab
Master Suite
91
19.5
None
1
No
Exposed Slab 2
Living
1763
134
None
0
No
Covered Slab 2
Living
182
48
None
1
No
Exposed Slab 3
Zone #3
614
38.5
None
0
No
Covered Slab 3
Zone #3
68
17.25
None
1
No
Exposed Slab 4
Zone #4
409
52
None
0
No
Covered Slab 4
,". Zone #4
45
32.8
None
1
No
BUILDING ENVELOPE - HERS VERIFICATION
01 N, s 02 03 04
Quality Insulation Installation (QII) Quality Installationpf Spray, oam Insulation-,.,, � Building Envelope Air Leakage CFM50
Not Required Not Re uired ' I Not Re uired� —
'I 'A i .%X yr Jr !r it Tl 1 € ]t 1E 1i I 3i'. 8i 14
WATER HEATING SYSTEMS
01 02 03 _ 04 Ob 08 07 nR
R1r� P►R .1+� Tom•: N1'R
+xr4. !! MWhF.i.
y:w•
01
02 N
1 tG; IES �> 03 It " 7k
S— } 'V t tW i:.
VA 05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Standard 1
DHW Heater 1
1
.0%
DHW Sys 3 - 1/1
DHW
Standard
DHW Heater 3
1
.0%
WATER HEATERS
01 02 03 _ 04 Ob 08 07 nR
Tank Exterior
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0
0.94
199900-Btu/hr
0
0
DHW Heater 3
Natural Gas
Small Instantaneous
0
0.94
199900-Btu/hr
0
0
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Tlme: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-0411:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: SmithRevised.xml
CFI R -PRF -01
Page 10 of 13
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
—
—
—
—
—
—
DHW Sys 3 - 1/1
—
—
—
—
—
—
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Zone #11
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Zone #22
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Zone #33 '�
Other -Heating and Cooling System
-
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
Zone #44 i' , r
Other He Sy earrid Goolingt
Heating poet 4
rooting Component 4,r
l I/
HVAC Fan 4
Air Distribution System 4
. ! s`-.1 %C x4 id 1 11 1\ 36 VIE A I€ lk 7F it Jk111.
HVAC - HEATING UNIT TYPES ? �/
,, „y tJV
l
01
# *4 w s s 02 'iwr, 's. V v.+r . , a
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntriFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: 215-N64a3645A-000000000-0000 Registration Date/Time: 2015.11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-0411:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: SmithRevised.xml
CFI R -PRF -01
Page 11 of 13
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
I` ,' `� ` 02
03
Efficiency
05
Mufti -speed
Name
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13.5
18
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 2
SplitAirCond
11.7
15
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 3
SplitAirCond
16.5
26
Not Zonal
Single Speed
Cooling Component
2 -hers -dist
Air Distribution System 3
DuctsAttic
Sealed and tested
1 -hers -cool
Cooling Component 4
SplitAirCond
16.5
26
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
I s
02
03
04
05
01
I` ,' `� ` 02
03
04
05
06
Name
Verified Airflow Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
/1'� Required
Required
Required
Cooling Component 2 -hers -cool
Required
1 [ 050
E '-- Not Reywred � k
Required
Required
Cooling Component 3 -hers -cool
',Required
U 1.350? LI U
U C::�� [Required.: 6 :5 0
Required
Required
Cooling Component 4 -hers -coot 2,1
Required
'S 350
C) V Regained fJZ=
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1 -hers -dist
Air Distribution System 2
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
2 -hers -dist
Air Distribution System 3
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
3 -hers -dist
Air Distribution System 4
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
4 -hers -dist
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 11:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Input File Name: SmithRevised.xml
CFI R -PRF -0'
Page 12 of 13
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -fist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
Air Distribution System 3 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
Air Distribution System 4 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
—
HVAC - FAN SYSTEMS
01
02
01 1 1/ '�,
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
j Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
�.,' Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
�. - - Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan r..`, - -
0.58
HVAC Fan 4 -hers -fan
r{ r— —11 i t i t l i . 1i If 1£ i t_ 1 i
HVAC FAN SYSTEMS -HERS VERIFICATION f-
01
02
01 1 1/ '�,
It"- >w a'w 1e"1a g,02 �✓^4 +iR a'" �r" e -•s
03
Name
6-. �`' Verified Fan Watt Draw w iii—o' v
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
HVAC Fan 3 -hers -fan
Required
0.58
HVAC Fan 4 -hers -fan
Required
0.58
IAQ (Indoor Air Quality) FANS _
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
137.49
0.25
Default
0
Required
Registration Number: 215-N6403645A-000000000-0000 Registration Date/Time: 2015-11-23 09:51:30 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-0411:57:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Smith Residence Calculation Date/Time: 11:55, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: SmithRevised.xml
CF1 R -PRF -01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Micah Combs
Company:
Signature Date:
CM Energy Consulting
2015-11-23 09:50:01
Address:
CEA/HERS Certification Identification (If applicable):
42-635 Melanie Place, Ste 102
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-346-8014
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency,for approval with this-buildingpermita ation.
l
Responsible Designer Name:I
y
I L
Responsible Designer Signature:
Christopher McFadden
{ E � -,
r7
Company:
S P
Date;Signed-
McFadden Architects
2015-11-23 09:51:30
Address:
License:
75-145 St. Charles PI., Ste. 4
C17837
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-346-8014
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N6403645A-000000000-0000 Registration Datenme: 2015-11-23 09:51:30 HERS Provider: CeICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 11:57:23
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Smith Residence
Building Type m single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11/4/2015
Project Address
80-770 Via Montecito La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,999
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavi (fir
Special Features Status
Roof Wood Framed Attic
R 38 Z863
New
Wall Wood Framed
R 21 4,909
New
Slab Unheated Slab -on -Grade
- no insulation 3,999
Perim = 401'
New
Roof Wood Framed Attic
R 30 1,136
New
FENESTRATION
Orientation Area ft2
I Total Area: 1,542 Glazing Percentage: 38.6 %
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor. 0.31
Exterior Shades Status
Left (SVtq 24.0
0.260
0.17 1.0
1.00/1.00
Bug Screen New
Rear (NVt9 108.0
0.290
0.17 9.0
0.00/11.00
Bug Screen New
Rear (NKK 20.0
0.280
0.17 none
8.50/0.00
Bug Screen New
Rear (NVt9 112.0
0.290
0.17 1.0
1.00/1.00
Bug Screen New
Right (NE) 63.0
0.290
0.17 13.0
10.00/0.00
Bug Screen New
Right (NE) 48.0
0.290
0.17 1.0
1.00/1.00
Bug Screen New
Right (NE) 63.0
0.290
0.17 none
0.00/19.00
Bug Screen New
Right (NE) 48.0
0.290
0.17 12.0
none
Bug Screen New
Right (NE) 7.0
0.260
0.17 11.0
none
Bug Screen New
Right (NE) 14.0
0.260
0.17 13.0
none
Bug Screen New
Right (NE) 92.0
0.280
0.17 1.0
1.00/1.00
Bug Screen New
Front (SE) 44.4
0.260
0.17 1.0
1.00/1.00
Bug Screen New
Front (SE) 24.0
0.280
0.17 2.0
2.5012.50
Bug Screen New
Front (SE) 48.0
0.290
0.19 none
1.00/1.00
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner
18.0 SEER
Setback
New
1 Central Fumace
80% AFUE
Split Air Conditioner
15.0 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner
26.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R -Value Status
Zone #1 Ducted
Ducted Attic
8.0
New
Zone #2 Ducted
Ducted Attic
8.0
New
Zone #3 Ducted
Ducted Atffc
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff
Distribution Status
1 Small Instantaneous Gas
0
0.94
Standard
New
1 Small Instantaneous Gas
0
0.94
Standard
New
EnergyPro 6.7 by EnemySoff User Number. 1086
RunCode: 2015-11-04715:41:00
ID: 1432.01
Pae 16 of 21
'RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Smith Residence
Building Type
m Single Family ❑ Addition A ne
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11/4/2015
Project Address
80-770 Via Montecito La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,999
Addition
# of Units
INSULATION
Construction Type
Cavi(ft)
Area
Special Feats res Status
FENESTRATION
Orientation Area ft2
I Total Area: 1,542 Glazing Percentage: 38.6 %
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor. 0.31
Exterior Shades Status
Front (SE) 25.0
0.290
0.19 4.0
1.00/1.00
Bug Screen New
Front (SE) 24.0
0.290
0.19 4.0
none
Bug Screen New
Front (SE) 48.0
1.040
0.63 none
none
Bug Screen New
Left (SW 28.0
0.260
0.17 none
9.00/0.00
Bug Screen New
Rear (Wo 177.0
0.290
0.17 none
0.00/7.00
Bug Screen New
Rear (NVt9 99.0
0.290
0.17 9.0
0.00/7.00
Bug Screen New
Rear (NVt9 149.0
0.300
0.18 11.0
0.00/11.00
Bug Screen New
Rear (NW) 24.0
0.280
0.17 none
10.00/0.00
Bug Screen New
Rear (NM 32.0
0.260
0.17 5.0
4.00/4.00
Bug Screen New
Rear (AIM 21.0
0.260
0.17 none
none
Bug Screen New
Rear (NVV) 64.0
0.290
0.17 7.5
30.00/1.00
Bug Screen New
Rear (NKK 64.0
0.290
0.17 7.5
1.00/1.00
Bug Screen New
Rear (NKK 48.0
0.260
0.17 7.5
1.00/1.00
Bug Screen New
Rear (NVt9 24.0
0.280
0.17 2.0
2.50/2.50
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner 26.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
Zone #4 Ducted
Ducted
Attic
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnemyPro 6.7 by EnergySoft User Number. 1086
RunCode: 2015-11-04T15:41:00
ID: 14U2.01
Pae17 of 21
2.013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §l 10.8(1) when the
installation of a cool roof is specified on the CF IR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(8)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§ 150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§l 10.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of §110.2(c).
§ 150.00)1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)]B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
alt hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A-
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing enc roved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 18113 or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y. inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All an systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§110.4(b)l:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
ammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of §150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting r electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 11.0.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with §150.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, § 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110. 9, § 130.02 § 130.2 § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§150.0(k)ll:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9, § 130.0, § 130. 1, § 130.4, 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with therequirements of § 110.10 b through 110.10(e).
§110.10(a)2:
Low-rise multi -family buildings shall comply with therequirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.